• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 13
  • 10
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avalia??o cl?nica de pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner

Ara?jo, Pryscyla Pascally Targino 19 December 2012 (has links)
Made available in DSpace on 2014-12-17T15:43:51Z (GMT). No. of bitstreams: 1 PryscylaPTA_DISSERT.pdf: 1471076 bytes, checksum: 63eee78ee148fad88e300caf30aa4256 (MD5) Previous issue date: 2012-12-19 / This study aimed to evaluate patients who underwent placement of zygomatic implants technique by Stella & Warner, considering the survival of conventional and zygomatic implants, sinus health and level of patient satisfaction in relation to oral rehabilitation. We evaluated 28 patients where 14 had received conventional and zygomatic implants, being rehabilitated with implant-fixed dentures (group 1) and 14 were rehabilitated only with conventional implants and implant-fixed dentures (group 2). The study had four phases, represented by radiographic evaluation of implants (stage I), clinical evaluation (stage II), assessing the health of the maxillary sinus (stage III) and a questionnaire to measure satisfaction of rehabilitation with fixed prosthesis implant Total -backed (stage IV). Group 2 underwent only stage IV, while group 1 participated in all stages. Descriptive analysis and statistics were performed, using the t test for independent samples in the evaluation of phase IV. The results demonstrated that the technique of Stella & Warner proved effective, allowing a high survival rate of conventional implants and zygomatic (100%), considering a minimum follow-up of 15 months and maximum 53 months after prosthetic rehabilitation. There were no pathological changes in tissues periimplants conventional and zygomatic implants analyzed. Radiographic findings showed satisfactory levels bone implants in the oral rehabilitation with conventional zygomatic implants and a good positioning of the apex of the zygomatic implants over the zygomatic bone. The presence of the zygomatic implant did not cause sinus and the t test showed a satisfaction index lower in group 1 compared with group 2. The zygomatic implant placement technique by Stella & Warner proved to be a predictable technique with high survival rate in patients with atrophic jaws, necessitating long-term follow-up to confirm the initial findings of the study / Este trabalho se prop?s a avaliar pacientes submetidos ? coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner, considerando a sobreviv?ncia dos implantes convencionais e zigom?ticos, a sa?de do seio maxilar e o n?vel de satisfa??o dos pacientes em rela??o ? reabilita??o oral. Foram avaliados 28 pacientes, onde 14 haviam recebido implantes zigom?ticos e convencionais, encontrando-se reabilitados com pr?teses totais fixas implantossuportadas (grupo 1) e 14 foram reabilitados somente com implantes convencionais e pr?teses totais fixas implantossuportadas (grupo 2). O estudo teve quatro fases, representadas pela avalia??o radiogr?fica dos implantes (fase I), avalia??o cl?nica (fase II), avalia??o da sa?de do seio maxilar (fase III) e aplica??o de um question?rio para mensurar a satisfa??o da reabilita??o com pr?tese fixa total implanto-suportada (fase IV). O grupo 2 s? foi submetido a fase IV, enquanto o grupo 1 participou de todas as etapas. Foram realizadas an?lises descritivas e estat?sticas, tendo, esta ?ltima, utilizado o test t para amostras independentes na avalia??o da fase IV. Os resultados demonstraram que a t?cnica de Stella & Warner mostrou-se efetiva, permitindo um elevado ?ndice de sobreviv?ncia dos implantes convencionais e zigom?ticos (100%), considerando um per?odo m?nimo de acompanhamento de 15 meses e m?ximo de 53 meses ap?s reabilita??o prot?tica. N?o foram encontradas altera??es patol?gicas nos tecidos periimplantares dos implantes convencionais e zigom?ticos analisados. Os achados radiogr?ficos mostraram n?veis ?sseos satisfat?rios nos implantes convencionais das reabilita??es orais com fixa??es zigom?ticas e um bom posicionamento do ?pice dos implantes zigom?ticos em rela??o ao osso zigom?tico. A presen?a do implante zigom?tico n?o provocou sinusopatias e o teste t demonstrou um ?ndice de satisfa??o inferior no grupo 1 quando comparado ao grupo 2. A coloca??o de implantes zigom?ticos pela t?cnica de Stella & Warner mostrou ser uma t?cnica previs?vel, com alto ?ndice de sobreviv?ncia em pacientes com maxilas atr?ficas, sendo necess?rio um acompanhamento por longo prazo para confirmar os achados iniciais desse estudo
12

Avaliação da tensão gerada em intermediários e região peri-implantar simulada após aperto de parafusos para fixação de infraestruturas confeccionadas por duas técnicas CAD/CAM e convencional / Evaluation of strain generated in abutments and peri-implant simulated region after tightening screws on frameworks made by conventional and two CAD/CAM techniques

Braga, Adriana de Castro Oliveira Pereira 27 August 2013 (has links)
A passividade tem sido descrita como um requisito importante para a longevidade de restaurações implanto-suportadas e, na busca incessante por materiais e técnicas que desempenhem um melhor resultado biomecânico para este tipo restauração, surgem os métodos baseados em desenho e manufatura auxiliados por computador, os chamados métodos CAD/CAM. Assim, o objetivo deste estudo foi comparar o desenvolvimento de tensão provocado pela fixação, por meio do aperto de parafusos, de infraestruturas confeccionadas por duas técnicas CAD/CAM e pela técnica convencional da cera perdida. Para a realização do experimento, foi confeccionado um modelo em poliuretano com dois implantes hexágono externo posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) infraestruturas em Ni-Cr fundidas pela técnica convencional da cera perdida; (U) infraestruturas em zircônia confeccionadas pela técnica CAD/CAM de usinagem e (S) infraestruturas em Co-Cr confeccionadas pela técnica CAD/CAM de sinterização a laser. Durante o aperto dos parafusos para fixação das infraestruturas, as tensões geradas foram registradas por extensômetros unidos aos intermediários e material de osso simulado. De acordo com a técnica utilizada e considerando todos os diferentes locais avaliados, os valores médios de tensão variaram de: 14,28 μξ a 693,40 μξ para o Grupo C; 19,27 μξ a 930,92 μξ para o Grupo U e 5,37 μξ a 196,57 μξ para o Grupo S. Análise de variância a dois critérios para as variáveis técnica de confecção de infraestruturas e local de avaliação da tensão demonstrou que não houve diferença estatisticamente significante entre os valores de tensão em relação à técnica utilizada. Por outro lado, os valores foram significantemente diferentes em relação aos diferentes locais analisados. Desta forma, este estudo concluiu que as duas técnicas CAD/CAM testadas não proporcionaram infraestruturas com passividade superior às obtidas convencionalmente e que todas as peças apresentaram certo grau de desadaptação e consequente falta de homogeneidade na distribuição de tensões pelo sistema. / Passivity property has been described as an important requirement for the longevity of implant-supported restorations. Looking for materials and techniques that provide better biomechanical outcome for such restorations, methods based on design and computer aided manufacturing has emerged, the called CAD/CAM techniques. Therefore, the aim of this study was to compare the strain development during tightening screws on frameworks made from two CAD/CAM techniques and conventional lost wax technique. For the experiment, a polyurethane model with two external hexagon implants, placed at 43 and 45 teeth areas, was made. From this model, 12 three-unit frameworks were produced and divided into 3 groups (n = 4) according to the technique used: (C) Ni-Cr cast frameworks produced by lost wax conventional technique; (U) zirconia frameworks prepared by CAD/CAM milling technique and (S) Co-Cr frameworks prepared by CAD/CAM laser sintering technique. Generated strains, during tightening screws, were recorded by strain gauges attached to abutments and simulated bone material. According to the technique used, which considered, all different sites evaluated, mean strain values ranged from: 14,28 μξ to 693,40 μξ for Group C; 19,27 μξ to 930,92 μξ for Group U and 5,37 μξ to 196.57 μξ for Group S. Two way ANOVA performed for frameworks technique and strain sites demonstrated no statistically significant difference between strain values in relation to the technique used. On the other hand, values were statistically different for distinct sites analyzed. Furthermore, this study concluded that the two CAD/CAM techniques tested did not provide frameworks with better passivity than conventionally obtained ones and that all parts showed some degree of mismatch and consequent lack of homogeneity related to stresses distribution through the system.
13

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
14

Sobrevida de implantes submetidos à carga funcional imediata na região interforaminal através do uso de anéis de retenção isolados em uma prótese total removível / Survival rates of implants submited to immediate funcional load in the interforaminal region using retention rings on a removable complete denture

Renato da Silva Fraga 12 March 2009 (has links)
O presente trabalho teve como objetivo comparar clinicamente através da taxa de sobrevida e análise de freqüência de ressonância, dois implantes instalados na região anterior da mandíbula, submetidos à carga funcional imediatamente a instalação dos implantes, através de anéis de retenção isolados presos a uma sobredentadura, com um implante instalado na mesma região, livre de carga funcional. Com este objetivo, onze pacientes foram selecionados para instalação de três implantes osteointegráveis em cada, sendo o implante livre de cargas funcionais utilizado como grupo controle. Através dos resultados obtidos, dos vinte e dois implantes submetidos à carga funcional imediata, dois foram perdidos, apresentando uma taxa de sobrevida proporcional a amostra de 93.9%. Quanto ao grupo controle, nenhum implante foi perdido. Após 4 anos de controle clínico, todos os implantes apresentam-se osteointegrados. / The present study aimed to clinically compare through resonance frequency analysis and survival rate, one implant installed in the mandibular anterior region, free from functional load, with two implants installed in the same region, submitted to immediate functional load through isolated retention rings attached to an overdenture. With this purpose, eleven patients were selected for installation of three implants in each. The implants free from functional load were used as the control group. Through the obtained results, two implants of the twenty-two implants submitted to immediate functional load were lost, representing a survival rate of 93.9%. As for the control group, no implants were lost. After 4 years of clinical control all implants remained integrated.
15

Avaliação da tensão gerada em intermediários e região peri-implantar simulada após aperto de parafusos para fixação de infraestruturas confeccionadas por duas técnicas CAD/CAM e convencional / Evaluation of strain generated in abutments and peri-implant simulated region after tightening screws on frameworks made by conventional and two CAD/CAM techniques

Adriana de Castro Oliveira Pereira Braga 27 August 2013 (has links)
A passividade tem sido descrita como um requisito importante para a longevidade de restaurações implanto-suportadas e, na busca incessante por materiais e técnicas que desempenhem um melhor resultado biomecânico para este tipo restauração, surgem os métodos baseados em desenho e manufatura auxiliados por computador, os chamados métodos CAD/CAM. Assim, o objetivo deste estudo foi comparar o desenvolvimento de tensão provocado pela fixação, por meio do aperto de parafusos, de infraestruturas confeccionadas por duas técnicas CAD/CAM e pela técnica convencional da cera perdida. Para a realização do experimento, foi confeccionado um modelo em poliuretano com dois implantes hexágono externo posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) infraestruturas em Ni-Cr fundidas pela técnica convencional da cera perdida; (U) infraestruturas em zircônia confeccionadas pela técnica CAD/CAM de usinagem e (S) infraestruturas em Co-Cr confeccionadas pela técnica CAD/CAM de sinterização a laser. Durante o aperto dos parafusos para fixação das infraestruturas, as tensões geradas foram registradas por extensômetros unidos aos intermediários e material de osso simulado. De acordo com a técnica utilizada e considerando todos os diferentes locais avaliados, os valores médios de tensão variaram de: 14,28 μξ a 693,40 μξ para o Grupo C; 19,27 μξ a 930,92 μξ para o Grupo U e 5,37 μξ a 196,57 μξ para o Grupo S. Análise de variância a dois critérios para as variáveis técnica de confecção de infraestruturas e local de avaliação da tensão demonstrou que não houve diferença estatisticamente significante entre os valores de tensão em relação à técnica utilizada. Por outro lado, os valores foram significantemente diferentes em relação aos diferentes locais analisados. Desta forma, este estudo concluiu que as duas técnicas CAD/CAM testadas não proporcionaram infraestruturas com passividade superior às obtidas convencionalmente e que todas as peças apresentaram certo grau de desadaptação e consequente falta de homogeneidade na distribuição de tensões pelo sistema. / Passivity property has been described as an important requirement for the longevity of implant-supported restorations. Looking for materials and techniques that provide better biomechanical outcome for such restorations, methods based on design and computer aided manufacturing has emerged, the called CAD/CAM techniques. Therefore, the aim of this study was to compare the strain development during tightening screws on frameworks made from two CAD/CAM techniques and conventional lost wax technique. For the experiment, a polyurethane model with two external hexagon implants, placed at 43 and 45 teeth areas, was made. From this model, 12 three-unit frameworks were produced and divided into 3 groups (n = 4) according to the technique used: (C) Ni-Cr cast frameworks produced by lost wax conventional technique; (U) zirconia frameworks prepared by CAD/CAM milling technique and (S) Co-Cr frameworks prepared by CAD/CAM laser sintering technique. Generated strains, during tightening screws, were recorded by strain gauges attached to abutments and simulated bone material. According to the technique used, which considered, all different sites evaluated, mean strain values ranged from: 14,28 μξ to 693,40 μξ for Group C; 19,27 μξ to 930,92 μξ for Group U and 5,37 μξ to 196.57 μξ for Group S. Two way ANOVA performed for frameworks technique and strain sites demonstrated no statistically significant difference between strain values in relation to the technique used. On the other hand, values were statistically different for distinct sites analyzed. Furthermore, this study concluded that the two CAD/CAM techniques tested did not provide frameworks with better passivity than conventionally obtained ones and that all parts showed some degree of mismatch and consequent lack of homogeneity related to stresses distribution through the system.
16

Mekaniska och kemiska egenskaper hos PEEK och PEKK inom tandvården : En systematisk översikt / Mechanical and chemical properties of PEEK and PEKK in dentistry : A systematic review

Öjvindsson Hörgård, Cecilia, Aso, Vanja January 2023 (has links)
Syfte Syftet med föreliggande studie är att genom en systematisk översikt identifiera skillnaderna i de kemiska och mekaniska egenskaperna hos materialen PEEK och PEKK och till vilka dentala applikationer materialen kan användas.  Material och metod Materialens kemiska och mekaniska egenskaper identifierades genom litteratursökning med PRISMA och PICO-systemet. Databaserna som användes var PubMed, Scopus samt Web of Science. Granskning gjordes på titel-, abstrakt- och fulltextnivå, baserat på inklusions- och exklusionskriterier. Resultat Sökningen resulterade i totalt 226 artiklar varav 210 artiklar i PubMed, nio artiklar i Scopus och sju artiklar i Web of Science. Efter kontroll av dubbletter och bedömning utifrån inklusions- och exklusionskriterier var det totalt sju artiklar som analyserades på fulltextnivå. Av dessa sju artiklarna utvärderades olika materialegenskaper där de använda materialtesterna skiljde sig åt. I fem artiklar utvärderades bindningsstyrkan mellan fasadmaterial och PEEK och/eller PEKK. En artikel undersökte ytan hos materialen beroende på ytbehandling och en artikel testade tryckhållfasthet på tre-ledsbroar av PEEK och PEKK. Båda materialen uppvisade liknande mekaniska och kemiska egenskaper vid jämförelse mot varandra.  Slutsats PEEK och PEKKs mekaniska och kemiska egenskaper skiljer sig inte åt. Mer forskning och kliniska data behövs om materialens dentala applikationer. Nyckelord: Avtagbar protetik, fast protetik, högpresterande polymer, PAEK, tandvård / Purpose The purpose of the present study is to carry out a systematic review to identify the differences in mechanical and chemical properties of the materials PEEK and PEKK, as well as which  dental applications the materials can be used for.  Material and method The materials’ mechanical and chemical properties were identified using PRISMA and PICO system through a literature search. The databases used were PubMed, Scopus and Web of Science. Screening and assessing were done at title, abstract and full text level, based on the inclusion and exclusion criteria. Results The search resulted in a total of 226 articles, whereon 210 articles in PubMed, nine articles in Scopus and seven articles in Web of Science. After removal of duplicates and assessment of the studies according to the inclusion and exclusion criteria, the total amount of studies reviewed was seven. In these seven articles, different properties were evaluated, and the tests used differed. In five articles, the shear bond strength between veneering materials and PEEK and/or PEKK was tested. In one article the surface roughness depending on surface treatment was tested and in another, the strength of three-unit fixed dental prostheses made of PEEK and PEKK was tested. PEEK and PEKK showed similar mechanical and chemical properties in comparison to each other.  Conclusion The mechanical and chemical properties of PEEK and PEKK do not differ. More research and clinical data are needed on the dental applications of the materials.Keywords: Dentistry, fixed dental prosthesis, high-performance polymer, removable dental prothesis, PAEK.

Page generated in 0.1285 seconds