• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 584
  • 175
  • 35
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 800
  • 376
  • 209
  • 164
  • 147
  • 143
  • 104
  • 103
  • 80
  • 79
  • 71
  • 62
  • 61
  • 60
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Transferts d'eau et de chaleur dans une pile à combustible à membrane : mise en évidence expérimentale du couplage et analyse des mécanismes.

Thomas, Anthony 23 November 2012 (has links) (PDF)
Les piles à combustible à membrane échangeuse de protons (PEMFC) permettent de convertir efficacement de l'énergie chimique en électricité. Pour cela l'hydrogène s'oxyde sur une des électrodes de la pile, les protons ainsi créés traversent l'électrolyte (membrane) tandis que les électrons parcourant le circuit extérieur fournissent l'énergie électrique. Tous ces éléments se recombinent à la seconde électrode qui, à l'aide de la réduction de l'oxygène, va former de l'eau. Le rendement n'étant pas parfait, une partie de l'énergie des réactifs est aussi dégradée sous forme de chaleur. Malgré de récents progrès, la commercialisation à grande échelle des piles à combustible est toujours entravée par des problèmes de durabilité, liés notamment à la gestion de l'eau et de la température au sein de ce système. Afin de quantifier le comportement thermique et son effet sur le transport de l'eau, une pile à combustible a été instrumentée, permettant la mesure de la température aux électrodes, des flux de chaleur et d'eau. Les résultats montrent que de forts gradients de température (jusqu'à environ 30 K/mm) peuvent exister pour une pile fonctionnant dans des conditions standard. Il a été observé une nette influence du champ de température dans le cœur de pile sur le transport de l'eau qui se fait vers la partie la plus froide de la pile (généralement les canaux d'alimentation), l'eau traversant les couches de diffusion poreuses sous forme vapeur dans nos conditions expérimentales.
152

Etude d'un système combiné de ventilation et de chauffage au bois dans les bâtiments à basse consommation d'énergie

Peigné, Pierre 27 February 2012 (has links) (PDF)
Ce travail porte sur l'étude et le développement d'un système innovant de ventilation et de chauffage au bois dans les habitations à basse consommation d'énergie, qui sont appelées à devenir la référence constructive en France dès 2015. Dans ces habitations fortement isolées et particulièrement étanches à l'air, les besoins de chauffage sont très faibles et peuvent être couverts par une source de chaleur d'origine renouvelable, telle que le bois énergie. En outre, l'utilisation d'une ventilation performante s'impose comme étant un critère essentiel pour assurer la bonne qualité de l'air intérieur et peut même devenir l'unique vecteur de chauffage en apportant l'appoint de chaleur sur l'air insufflé dans les différentes pièces de l'habitation. Le système présenté dans cette étude propose ainsi de combiner les avantages d'un appareil de chauffage au bois de petite puissance, ici un poêle à granulés de bois, et ceux d'une ventilation à récupération de chaleur sur l'air extrait, grâce à un conduit échangeur intégré à la cheminée du poêle et relié au réseau de soufflage de la ventilation. Développé en partenariat avec l'industriel POUJOULAT, spécialisé dans la fabrication de conduits de cheminée métalliques, ce conduit échangeur permet de récupérer sur l'air neuf une partie de la chaleur initialement perdue par les fumées et de la distribuer dans toutes des zones de vie de l'habitation, même les plus éloignées de l'appareil au bois. Après avoir défini la configuration de couplage à adopter pour assurer le bon fonctionnement de l'ensemble et garantir à la fois la sécurité et le confort des occupants, les performances de plusieurs prototypes de conduit échangeur sont caractérisées expérimentalement. Les résultats obtenus lors des essais en laboratoire permettent alors d'orienter l'évolution des prochains prototypes et de souligner la nécessité de travailler avec un poêle à granulés de bois dont le cycle de combustion est étanche. Un modèle mathématique est également développé pour prédire les performances du dernier prototype de conduit échangeur à triple paroi non isolé sur sa surface extérieure et sa validation est obtenue suite au bon accord entre les résultats calculés et ceux mesurés lors des essais. L'ensemble du système combiné est ensuite installé dans deux habitations à basse consommation d'énergie situées près de Poitiers. L'exploitation des températures et des consommations recueillies pendant la première saison de chauffe montre la bonne tenue du système combiné, ses limites, ainsi que ses conditions d'appropriation par les occupants, dont le comportement apparaît jouer un rôle prédominant dans la réduction des consommations énergétiques.
153

Amélioration de l'efficacité énergétique d'une solution innovante de chauffage basse température et de rafraîchissement

David, Benjamin, David, Benjamin 09 December 2011 (has links) (PDF)
Dans le contexte actuel d'amélioration de l'efficacité énergétique des logements, il est nécessaire de repenser les installations de chauffage. Nous avons développé un générateur de chaleur et de rafraîchissement innovant (GCRI). Ce générateur repose sur l'utilisation de modules thermoélectriques assurant le rôle de pompe à chaleur au moyen d'une alimentation électrique. La présente thèse vise à améliorer l'efficacité énergétique du système complet incluant un émetteur basse température (coefficient de performance global). Ce travail repose sur différents modèles analytiques et numériques validés expérimentalement. Ces modèles ont permis de définir une configuration optimisée du système et de mettre en place une méthode de gestion optimale pour répondre à des besoins variables de puissance et de températures. Les échangeurs multifonctionels mis en jeu dans le système ont été dimensionnés et étudiés expérimentalement en vue de maximiser les performances du générateur. Après couplage au bâtiment, nous montrons une nette amélioration des performances du système par rapport à une configuration classique de pompe à chaleur thermoélectrique.
154

Micro-cogénération pour les bâtiments résidentiels fonctionnant avec des énergies renouvelables

Aoun, Bernard 13 November 2008 (has links) (PDF)
La consommation d'énergie des secteurs résidentiel et tertiaire constitue 43 % de la consommation finale nationale, correspondant à 25 % des émissions nationales de CO2. Différentes options techniques existent pour limiter les émissions CO2 dans ce secteur et pour améliorer la performance énergétique des bâtiments. Une de ces options est présentée et étudiée dans cette thèse : le développement d'un système de micro-cogénération fonctionnant avec des énergies renouvelables l'une intermittente (le solaire), l'autre non (une chaudière à bois). Les systèmes de micro-cogénération conventionnels ont été analysés. Le but de la thèse est de développer un système de micro-cogénération basé sur un cycle organique et fonctionnant sur ces énergies renouvelables aux caractéristiques différentes. Plusieurs fluides de travail permettant d'atteindre des performances thermodynamiques élevées ont été comparés. Une analyse technologique a permis d'identifier les technologies les plus adaptées ou adaptables pour chacun des composants du système dépendant du fluide de travail choisi. Un banc d'essais a été conçu et réalisé pour tester et caractériser une turbine spiro-orbitale fonctionnant avec la vapeur d'eau et adaptée au système de micro-cogénération. Les composants du banc d'essais ont été dimensionnés en utilisant des outils informatiques de modélisation des cycles organiques. Un outil de simulation dynamique a été développé pour simuler le fonctionnement annuel de la micro-cogénération fonctionnant sous différentes conditions climatiques et charges thermiques. Les résultats ont démontré qu'il est possible d'économiser plus de 40 % d'énergie primaire et 60 % en émissions de CO2 par rapport à des bâtiments conformes à la réglementation thermique la plus récente (RT2005). Le coût de production de 1 kWel a été calculé selon un modèle économique ; ce prix, 50 c€/kWhel, reste élevé comparé à d'autres technologies.
155

Variabilité des flux turbulents de surface au sein du bassin versant d'Ara au Bénin

Doukoure, Moussa 31 March 2011 (has links) (PDF)
La circulation atmosphérique en Afrique de l'Ouest est caractérisée par des vents de sud-ouest (mousson) pendant la saison humide et par des vents de nord-est (harmattan) pendant la saison sèche. Cette alternance des saisons est due aux variations de pression liée à l'état des surfaces (rugosité, albédo, végétation) en réaction au forçage solaire. Ces mêmes états de surface génèrent une variabilité de flux turbulents de surface et des circulations secondaires qui rendent complexes les analyses des mesures effectuées sur place en vue de documenter les interactions surface-atmosphère. La modélisation fine échelle (LES) couramment utilisée dans l'étude de la couche limite atmosphérique est requise pour pouvoir palier à ces difficultés en raison de sa capacité à prendre en compte les flux turbulents en 3D et sur topographie complexe. Notre site d'étude est le bassin versant d'ARA située au Nord du Bénin dans un contexte Soudanien avec des propriétés de surface variables. Une analyse climatique est effectuée sur la base des observations de radiosondage, de radar UHF et de stations au sol afin d'extraire des données composites représentatives des saisons sèche et humide. Ces données composites ont servi par la suite à forcer le modèle Méso-NH dans sa version LES. Pour pouvoir caractériser les échelles de longueur des flux turbulents de surface relatives aux saisons sèche et humide, les données standard de forçage de surface de Méso-NH que sont le relief GTOPO30 (1km de résolution) et la végétation ECOCLIMAP (1km de résolution) ont été respectivement remplacer par le SRTM (90m de résolution) et les données de SPOT/HRV (20m de résolution) reéchantillonné à 90m de résolution. A l'aide d'outils statistiques comme la variographie 2D et le suivi Lagrangien, il ressort que la variabilité spatiale de la chaleur sensible H est gouvernée par le couple vent-relief tandis que celle de la chaleur latente E est difficile à mettre en lien sur végétation hétérogène (SPOT/HRV) en saison sèche. En saison humide, la variabilité spatiale du champ H dépend du vent tandis que celle du champ E dépend de la végétation. Cette étude révèle dans tous les cas que les échelles caractéristiques de ces deux champs diffèrent dans les mêmes conditions de forçage de surface et atmosphérique.
156

Variabilité des flux turbulents de surface au sein du bassin versant d'Ara au Bénin / Surface turbulent flux variability within the ara watershed in benin

Doukouré, Moussa 31 March 2011 (has links)
La circulation atmosphérique en Afrique de l'Ouest est caractérisée par des vents de sud-ouest (mousson) pendant la saison humide et par des vents de nord-est (harmattan) pendant la saison sèche. Cette alternance des saisons est due aux variations de pression liée à l'état des surfaces (rugosité, albédo, végétation) en réaction au forçage solaire. Ces mêmes états de surface génèrent une variabilité de flux turbulents de surface et des circulations secondaires qui rendent complexes les analyses des mesures effectuées sur place en vue de documenter les interactions surface-atmosphère. La modélisation fine échelle (LES) couramment utilisée dans l'étude de la couche limite atmosphérique est requise pour pouvoir palier à ces difficultés en raison de sa capacité à prendre en compte les flux turbulents en 3D et sur topographie complexe. Notre site d'étude est le bassin versant d'ARA située au Nord du Bénin dans un contexte Soudanien avec des propriétés de surface variables. Une analyse climatique est effectuée sur la base des observations de radiosondage, de radar UHF et de stations au sol afin d'extraire des données composites représentatives des saisons sèche et humide. Ces données composites ont servi par la suite à forcer le modèle Méso-NH dans sa version LES. Pour pouvoir caractériser les échelles de longueur des flux turbulents de surface relatives aux saisons sèche et humide, les données standard de forçage de surface de Méso-NH que sont le relief GTOPO30 (1km de résolution) et la végétation ECOCLIMAP (1km de résolution) ont été respectivement remplacer par le SRTM (90m de résolution) et les données de SPOT/HRV (20m de résolution) reéchantillonné à 90m de résolution. A l'aide d'outils statistiques comme la variographie 2D et le suivi Lagrangien, il ressort que la variabilité spatiale de la chaleur sensible H est gouvernée par le couple vent-relief tandis que celle de la chaleur latente E est difficile à mettre en lien sur végétation hétérogène (SPOT/HRV) en saison sèche. En saison humide, la variabilité spatiale du champ H dépend du vent tandis que celle du champ E dépend de la végétation. Cette étude révèle dans tous les cas que les échelles caractéristiques de ces deux champs diffèrent dans les mêmes conditions de forçage de surface et atmosphérique. / West Africa atmosphere circulation is characterized by south-westerly wind (monsoon regime) during the wet season and north-easterly wind (harmattan regime) during the dry season. This alternation of wind regime is due to surface pressure variability linked to surface heterogeneities. Surface heterogeneities generate surface flux variability, secondary circulation and make complex analysis when trying to document surface-atmosphere feedbacks. LES modelling usually used for boundary-layer studies due to its potential to take into account 3D turbulence over complex topography, is used here to overcome these difficulties. Our site of interest is located in north of Benin characterized by Soudanian climate and heterogeneous surface properties. Climate analysis are first performed with radiosoundings, UHF radar, and EC station data in order to extract composite profile representing dry and wet season.. These composite profiles are then used to force atmosphere part of the Méso-NH LES model. To characterize turbulent fluxes length scales relative to dry and wet season, standard surface forcing data with Méso-NH like GTOPO30 orography (1km ) and ECOCLIMAP vegetation (1km) are respectively replaced by SRTM (90m) and SPOT/HRV vegetation data (20m) resampled to 90m. Along with statistical tools like 2D variography and Lagrangian, we notice that during dry season on heterogeneous vegetation, sensible heat flux H is more driven by wind and orography while we not able to discuss the latent heat flux E case. During wet season with the same surface forcing, it appears that H is driven by wind while E is more dependent to vegetation variability. Our study concludes in all case that H and E are not characterized by the same length scale.
157

Low-temperature based thermal micro-grids : operation and performance assessments / Micro-réseaux de chaleur urbains basse température : évaluation du fonctionnement et de la performance

Castro Flores, Jose Fiacro 04 July 2018 (has links)
L’utilisation d'énergie en milieu urbain est essentielle pour le bon fonctionnement de notre société, en particulier pour les besoins de chauffage qui est un élément central de notre système énergétique souvent considéré comme allant de soi. Dans ce cadre, les systèmes énergétiques urbains et en particulier les réseaux de chaleur urbains ont besoin d’évoluer pour s'adapter à la transition à venir vers un système énergétique durable. Ce travail de recherche a pour objectif de présenter, de discuter et d’évaluer, du point de vue technico-économique, le concept de micro-réseaux de chaleur urbains basse température comme réseaux secondaires de distribution de chaleur actifs. Dans cette thèse, une approche méthodologique mixte basée sur la simulation analytique pour l'évaluation des alternatives est développée et discutée pour étudier une combinaison de technologies associées aux sous-stations basse température. Les principaux résultats de ce travail couvrent : le développement d’un modèle amélioré de charges thermiques agrégées ; la comparaison des performances des réseaux basse température ; l’analyse des avantages et des inconvénients des sous-stations actives couplées à des sources de chaleur ou du stockage distribuées ; et les effets d’une température de retour du réseau primaire plus basse. Les conclusions révèlent que la conception et le fonctionnement intégrés du micro-réseau de chaleur urbain actif ont le potentiel d'améliorer les performances de l'ensemble du système, afin de relever ses défis d'une manière efficace et rentable. Ce travail fait progresser les connaissances actuelles sur le chauffage urbain en identifiant les synergies et les enjeux associés, en vue de que ces technologies jouent un rôle clé dans le futur système énergétique intelligent et durable. / Energy use in the urban environment is vital for the proper functioning of our society, and in particular, comfort heating –and cooling– is a central element of our energy system that is often taken for granted. Within this context, district energy systems and especially, district heating (DH) systems must evolve to adapt to the upcoming decades-long transition towards a sustainable energy system. This dissertation seeks to introduce, discuss, and asses from a techno-economic perspective, the concept of low-temperature based thermal micro-grids (subnets) as active distribution thermal networks. For this purpose, a mixed methodological approach based on analytical simulation for the assessment of alternatives is developed and discussed to evaluate a set of technologies. Key findings of this research include: an updated and improved model of aggregated heat loads; the identification of differences in load and temperature patterns for certain LT subnets; the analysis of benefits and drawbacks of active substations with distributed heat sources and/or storage; and the impact of the reduction of the primary network return temperature, which leads to lower generation & operating costs. These outcomes reveal that the integrated design and operation of the active thermal micro-grid have the potential to improve the performance of the entire system, to address the matter of providing comfort heating in an effective and cost-efficient manner. This work advances the current DH knowledge by identifying synergies and challenges that arise with these new developments, in order for DH to play a key role in the future smart and sustainable energy system.
158

Amélioration de l'efficacité énergétique d'une solution innovante de chauffage basse température et de rafraîchissement / Improving the energy efficiency of an innovative low temperature heating and cooling

David, Benjamin 09 December 2011 (has links)
Dans le contexte actuel d'amélioration de l'efficacité énergétique des logements, il est nécessaire de repenser les installations de chauffage. Nous avons développé un générateur de chaleur et de rafraîchissement innovant (GCRI). Ce générateur repose sur l'utilisation de modules thermoélectriques assurant le rôle de pompe à chaleur au moyen d'une alimentation électrique. La présente thèse vise à améliorer l'efficacité énergétique du système complet incluant un émetteur basse température (coefficient de performance global). Ce travail repose sur différents modèles analytiques et numériques validés expérimentalement. Ces modèles ont permis de définir une configuration optimisée du système et de mettre en place une méthode de gestion optimale pour répondre à des besoins variables de puissance et de températures. Les échangeurs multifonctionels mis en jeu dans le système ont été dimensionnés et étudiés expérimentalement en vue de maximiser les performances du générateur. Après couplage au bâtiment, nous montrons une nette amélioration des performances du système par rapport à une configuration classique de pompe à chaleur thermoélectrique. / In the current context of improvement of the housing energy efficiency, new heating devices have to be foreseen. We have developed an innovative heating and cooling generator. This device is based on the use of thermoelectric modules working as a heat pump via a power supply. This thesis aims to improve the energy efficiency of the whole system including a low temperature heat floor (global coefficient of performance). This work is based on different analytical and numerical models validated experimentally. These models help to design an optimized device configuration and to develop an optimal management strategy in order to meet the variable power and temperature demands. Multifunctional heat sinks for the generator are designed and studied experimentally in order to maximize the system performances. By coupling the system to housing, a significant improvement of the device performances is shown compared to thermoelectric heat pumps with a classical configuration.
159

Contribution à l'étude des performances d'un séchoir serre avec stockage de chaleur dans des matériaux à changement de phase. / A study on thermal performance of a solar greenhouse dryer with heat storage in phase change materials

Aumporn, Orawan 07 December 2017 (has links)
Ce travail concerne une étude numérique des performances thermiques d’un séchoir- serre équipé d’une unité de stockage de chaleur solaire dans des matériaux à changement de phase (MCPs). L'unité de stockage de chaleur solaire, placée sous le sol de la serre, est composée d’une couche de MCPs (paraffine) disposée entre une plaque en acier et une couche de béton. L'écoulement de l'air asséchant se déroule par convection forcée et le produit disposé sur les claies du séchoir est la banane (Bananas Musa ABB CV. Kluai "Namwa"). Les équations de transfert de chaleur dans la serre, basées sur la méthode nodale, sont déduites d'un bilan thermique établi pour les différents composants du séchoir-serre. Les transferts de chaleur dans les couches de MCPs et de béton sont décrits respectivement par le modèle enthalpique et l'équation de la conduction. Le modèle de cinétique de séchage de la banane est celui d’Oswin modifié. Les équations de transferts sont résolues par une méthode implicite aux différences finies et les algorithmes de Gauss et de Thomas. Nous analysons l'influence du débit d'air asséchant et de l’irradiation solaire sur les distributions spatio-temporelles des températures des composants de la serre et de l'unité de stockage, la durée de séchage, les efficacités thermiques du séchoir-serre et de l'unité de stockage d'énergie. Cette modélisation est complétée par des simulations du fonctionnement du séchoir serre-unité de stockage de chaleur en utilisant la notion de journée type et les données météorologiques de Nakorn Pathom (Thaïlande) et par une analyse de faisabilité technico-économique. Les résultats montrent notamment que l’unité de stockage de chaleur contribue à la réduction de la durée de séchage et augmente les performances thermiques du séchoir et l’unité de stockage. / This work is about a numerical study of the thermal behavior of a solar greenhouse dryer and a heat storage unit in phase change materials (PCMs). The heat storage unit containing of PCMs (paraffin) is disposed between a metal plate and a concrete layer and placed under the floor of the greenhouse. The air drying flows along the greenhouse by forced convection and the products placed on the dryer's rack is bananas (Bananas Musa ABB CV Kluai "Namwa"). The heat transfer equations in the greenhouse are based on the nodal method and deduced from a thermal balance on the different components of the solar greenhouse dryer. The heat transfers in the PCMs and the concrete slab are described by the enthalpy method and the conduction equation, respectively. The banana drying kinetic is described by the model modified of Oswin. Transfer equations are solved using an implicit finite difference method associated to Gauss and Thomas algorithms. We analyze the effects of the air drying volumetric flow rate and the solar irradiance on the temperature distribution of the greenhouse dryer and the heat storage unit, the drying time, the solar greenhouse dryer and heat storage unit efficiencies. This modeling is complemented by simulations of the solar greenhouse dryer with the heat storage unit using the day type and the meteorological data of Nakorn Pathom (Thailand) and by an economic analysis. The results show that the heat storage unit provides the reduction of the drying time and increases the thermal performances of the solar greenhouse dryer and the heat storage unit.
160

Développement d’un nouveau thermo-transformateur à absorption-démixtion : optimisation conjointe du cycle et du mélange de travail / Development of a new absorption-demixing heat transformer : cycle and working mixture optimisation

Noubli, Halima 15 December 2010 (has links)
Ce travail porte sur l’étude d’un nouveau type de thermo-transformateur à absorption-démixtion (TTAD) utilisant un mélange présentant une lacune de miscibilité à basse température. Dans ce cycle, l’opération de séparation, est effectuée par décantation gravitaire par simple refroidissement du mélange. La séparation est ainsi énergétiquement gratuite et permet d’atteindre des rendements thermiques plus élevés que ceux des pompes à chaleur à absorption classiques dans lesquelles la séparation s’effectue par distillation.Afin de trouver des mélanges de travail pour atteindre un saut thermique de 50°C, un outil de simulation numérique a été développé pour évaluer les performances des TTAD en fonction des conditions opératoires (rapport d’alimentation et nombre d’étages de la colonne de rectification inverse) et des caractéristiques des composés du mélange de travail (Cp, Lv, paramètres caractéristiques des équilibres liquide-liquide et liquide-vapeur). L’optimisation des conditions opératoires a ainsi permis d’obtenir un saut thermique maximal de 12,4°C pour le mélange n-heptane / DMF pris comme référence. En faisant varier les propriétés des composés autour de celles de ce mélange de référence, un saut maximum de 32°C a été calculé pour un mélange fictif. L’étude de 17 mélanges réels a permis atteindre 21°C de saut thermique. Une liste d’autres mélanges à étudier a été établie. A l’aide d’une unité pilote d’une puissance de 4kW, des mesures expérimentales des performances du cycle modifié de TTAD pour le mélange n-heptane / DMF ont été réalisées et démontré la faisabilité de ce cycle même si le saut thermique de 11°C atteint au maximum est inférieur à celui calculé par simulation / This work is a study of a new type of Absorption-Demixing Heat Transformer (ADHT), using a mixture exhibiting a miscibility gap at low temperature. In this cycle, the separation step is performed by settling obtained after cooling the mixture. The separation is then energetically free and enables to reach thermal yields higher than those obtained for classical absorption heat transformers where separation is done by distillation.In order to find suitable working mixtures to reach temperature lift of 50°C, a numerical simulation tool was developed to calculate ADHT performances. This tool enabled to calculate thermal yield and thermal lift for different values of operating parameters (molar feed ratio, number of stages of rectification column) and different properties of working mixtures (Cp, Lv, parameters characterizing liquid-liquid and liquid-vapour equilibria). The best operating conditions allowed reaching a 12,4°C thermal lift for the n-heptane / DMF mixture takes as a reference mixture. By varying the mixture properties around the values of the reference mixture properties, a maximal thermal lift of 32°C was reached for an imaginary mixture. 17 real mixtures were also studied and enabled to reach a 21°C temperature lift. A list of other working mixtures that should be suitable was established. A 4 kW ADHT pilot unit was designed and built. The technical feasibility of this cycle was then experimentally demonstrated with this unit. A maximum temperature lift of 11°C was measured with the n-heptane / DMF mixture that is lower than the values calculated by simulation

Page generated in 0.0269 seconds