• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 584
  • 175
  • 35
  • 3
  • 1
  • 1
  • 1
  • Tagged with
  • 800
  • 376
  • 209
  • 164
  • 147
  • 143
  • 104
  • 103
  • 80
  • 79
  • 71
  • 62
  • 61
  • 60
  • 57
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Etude d’un système de stockage de chaleur thermochimique avec réacteur séparé / Design and analysis of a thermochemical heat storage process with separated reactor

Farcot, Lauren 09 March 2018 (has links)
Les systèmes de stockage thermochimique s’avèrent être de bonnes alternatives aux technologies actuelles pour le stockage saisonnier ou intersaisonnier de la chaleur, car l’énergie est stockée sous forme d’un potentiel chimique et donc, il n’y a pas de pertes thermiques pendant la durée de stockage. Un grand nombre d’études a été mené sur le développement de réacteurs thermochimiques intégrés au système de stockage, et peu d’étude ont été menées sur les technologies de réacteur séparé du réservoir de stockage. Ces dernières présentent cependant l’avantage, entre autres, de dissocier la puissance thermique du réacteur et la capacité de stockage de l’installation, ce qui permettrait d’augmenter la densité de stockage.Cette étude se penche sur le développement d’un réacteur thermochimique à lit mobile fonctionnant avec des sels hydratés sous air humide, adapté à des applications aux réseaux de chaleur. Un prototype de réacteur, développé et construit durant cette étude, a permis d’analyser le fonctionnement du réacteur. Cette étude a, entre autres, mis en évidence l’impact des passages préférentiels de l’air sur les performances du réacteur (température et puissance), ainsi que l’importance du titre de vapeur de l’air à l’entrée du réacteur sur ces performances. Il apparaît également que la circulation du solide abaisse sensiblement le point d’équilibre atteint par la réaction.De plus, deux modèles mathématiques ont été développés : un modèle analytique 1D et un modèle 2D prenant en compte les phénomènes de transfert de matière et de chaleur au sein de la zone réactive. Le modèle 2D, validé avec les résultats expérimentaux, a été exploité à l’aide du logiciel de simulation par éléments finis COMSOL Multiphysics afin de mener une étude théorique sur le fonctionnement et les performances du réacteur. Cette étude numérique a porté sur l’influence des conditions opératoires (débit et taux d’humidité de l’air, vitesse du solide) sur les performances et le rendement du système et a permis la comparaison des réacteurs à lit mobile par rapport aux réacteurs à lit fixes, communément développés pour des applications de stockage thermochimique. Cette étude a montré l’importance de la régulation de la vitesse du solide pour l’optimisation des performances du réacteur à lit mobile.L’ensemble de cette étude a permis de mettre en évidence les avantages et les limitations d’un réacteur à lit mobile pour des applications de stockage thermochimique / Thermochemical storage systems prove to be good alternatives to current technologies for seasonal or inter-seasonal storage of heat, because energy is stored as a chemical potential and therefore, there is no heat loss during the storage period. Nowadays, a large number of studies have been conducted on the development of thermochemical reactor integrated in the storage system, andlittle study has been conducted on reactor technologies separated from the storage system. The latter, however, have the advantage, among others, of separating the thermal power produced or consumed and the storage capacity of the installation, which would increase the storage density.This study investigates the development of a moving-bed thermochemical reactor operating with hydrated salts and humid air cross-flow, suitable for district heating applications. A reactor prototype, developed and built during this study, allowed to analyze the functioning of the reactor. This study has, among others, highlighted the impact of the preferential air flow path on the reactorperformances (temperature and power), as well as the importance of the air humidity at the reactor inlet on these performances.In addition, two mathematical models have been developed : a 1D analytical model and a 2D model taking into account the heat and mass transfer phenomena within the reactive area. The 2D model, validated with the experimental results, was exploited using the finite element simulation software COMSOL Multiphysics to conduct a theoretical study on the functioning and the performances of the reactor. This numerical study focused on the influence of operating conditions (air flow rate and moisture content, solid flow rate) on the performances and the efficiency of the system and allowed the comparison of moving bed reactor over fixed bed reactors, commonly developed for thermochemical storage applications. This study has shown the importance of solid velocity control for optimizing the performances of the moving bed reactor.This study has highlighted the advantages and limitations of moving bed reactors for thermochemical storage applications
182

Influence du métakaolin sur le comportement rhéologique et mécanique des bétons à hautes performances / Influence of metakaolin on the rheological and mechanical behavior of high perfomance concretes

Said Mansour, Mohamed 29 December 2010 (has links)
L'utilisation du kaolin calciné, sous forme de métakaolin, comme matériau pouzzolanique pour le mortier et le béton a suscité une attention considérable ces dernières années. Le travail actuel décrit les résultats d'un projet de recherche lancé pour étudier la calcination d'un kaolin local sous diverses températures (650-950°C) et durées (2, 3 et 4 heures) qui ont produit le métakaolin avec une activité pouzzolanique élevée. L'activité pouzzolanique a été évaluée par des méthodes de la chaleur d'hydratation et la résistance à la compression à 28 jours. L'activité maximale a été obtenue à une température de 850°C pendant 3 heures. Les résultats observés établissent qu'une augmentation de la chaleur d'hydratation et de la résistance à la compression a été obtenue lorsque le ciment Portland Ordinaire a été remplacé par 10% de métakaolin. L'utilisation du ciment ternaire améliore la résistance au jeune âge et à long terme. La durabilité a été également améliorée où une meilleure résistance des mortiers à l'attaque des acides a été observée. / The utilisation of calcined clay, in the form of metakaolin as a pozzolanic material for mortar and concrete has received considerable attention in recent years. The present work describes the results of a research project initiated to study the calcination of a local kaolin at various temperatures (650-950°C) and durations (2, 3 and 4 hours) to produced a metakaolin with a high pozzolanic activity. The pozzolanic activity was assessed by 28-days compressive strength and hydration heat methods. The maximum identified activity was obtained at 850°C for 3 hours duration. The observed results establish that an increase of both hydration heat and compressive strength was obtained when ordinary Portland cement was replaced by 10% metakaolin. The use of ternary blended cement improves the early age and the long-term compressive strength. The durability was also enhanced as better acidic resistance was observed.
183

De l'imagerie tissu entier à la modélisation in silico du réseau vasculaire du tissu adipeux

Dichamp, Jules 02 July 2018 (has links) (PDF)
Le tissu adipeux est traditionnellement décrit comme étant constitué de lobules : des entités de formes ovoïdales composées de cellules et de vaisseaux et faiblement connectées entre elles.Récemment, il a été montré qu’un potentiel métabolique spécifique (le browning) co-localise avec cette organisation en lobules au sein d’un même tissu. Dans ce travail de thèse, nous nous intéressons à décrire plus précisément l’organisation structurelle et fonctionnelle du tissu adipeux selon plusieurs aspects. Dans un premier temps, on s’attache à segmenter les lobules du tissu adipeux en utilisant une méthode de traitement d’image originale. Nous mettons en évidence une organisation 3D complexe et suivant plusieurs échelles. En particulier, il semble que le potentiel de browning soit également lié à une organisation structurelle particulière en clusters de lobules. Dans un second temps, à partir d’imagerie 3D, nous reconstruisons le réseau vasculaire entier du tissu adipeux et réalisons une simulation d’écoulements sanguins micro-vasculaires. Plusieurs hétérogénéités structurelles et fonctionnelles sont alors mises en valeurs à l’aide d’une analyse en communautés qui composent le tissu adipeux (par algorithme de clustering). Ces résultats confirment l’existence d’une zone centrale fortement vascularisée et qui se démarque également comme étant le lieu d’une perfusion sanguine d’intensité différente. Dans une dernière partie, nous abordons la question de transferts thermiques entre vaisseaux sanguins suivant des géométries simples mais pertinentes. Nous réalisons une étude systématique des paramètres adimensionnels clés du problème et mettons en évidence un invariant des échanges de chaleur : un optimum à faible nombre de Péclet (convection de même ordre que la diffusion). Nous introduisons également une méthode de calibration de paramètres effectifs dans le contexte des modèles homogénéisés de température à travers des tissus vascularisés.
184

Modélisation des transferts de masse et de chaleur dans une cellule d'électrolyse de production de fluor / Computer modeling of heat transfer and mass transfer in an electrolytic cell for production of fluorine

Vukasin, Julien 22 September 2017 (has links)
Modélisation des transferts de masse et de chaleur dans une cellule d'électrolyse de production de fluor. La production de fluor par électrolyse est une étape clé de la conversion de l’uranium dans l’industrie nucléaire. Afin d’optimiser ce procédé, les travaux de thèse décrits dans ce manuscrit se sont concentrés sur deux axes : le développement d’un modèle numérique de l’électrolyseur et l’étude du phénomène d’hyperpolarisation cathodique néfaste pour le bon fonctionnement de la cellule. Un modèle couplant plusieurs physiques (thermique avec solidification, diphasique, électrocinétique) a été développé et des essais expérimentaux ont été menés afin d’acquérir, d’une part, certaines propriétés physiques de l’électrolyte nécessaires aux simulations (conductivité thermique et capacité thermique à pression constante) et, d’autre part, des données expérimentales permettant de qualifier le modèle obtenu. Ce travail de modélisation a abouti à l’obtention d’un modèle 3D fiable couplant les physiques citées précédemment, ceci à l’échelle d’un pilote R&D semi-industriel. L’impact de la solidification de l’électrolyte sur le transfert de chaleur a également pu être simulé pour la première fois. Ces essais ont également permis de fournir des premières explications sur le phénomène d’hyperpolarisation cathodique en dressant des tendances claires quant à l’influence de certains paramètres de contrôle de l’électrolyseur comme le titre HF et la température de consigne. / Computer modeling of heat transfer and mass transfer in an electrolytic cell for production of fluorineElectrolytic production of fluorine is a key step in uranium conversion for the nuclear industry. In order to improve this process, the work described in this dissertation aims at two main objectives: to build a numerical simulation of the electrolysis cell and to understand the cathodic hyperpolarization effect which lowers the productivity of the cell. A model coupling several physics (heat transfer with solidification, two-phase flow, electrokinetics) has been developed and experiments were made in order to evaluate unknown physical properties of the electrolyte (thermal conductivity and heat capacity at constant pressure). Experimental data were also acquired in order to assess the capacity of the model to simulate various phenomena occurring inside the cell. Eventually, a reliable 3D model of a semi-industrial R&D cell coupling the physics above mentioned has been obtained. The negative impact of the solidification of the electrolyte on the cooling system was simulated for the first time. Thanks to these experiments, it was also possible to determine the major trends which drive the cathodic hyperpolarization effect. The influence of HF mass fraction and temperature on this phenomenon was clearly shown.
185

Étude d’un système tritherme intégrant une compression thermique originale, destiné au marché du chauffage résidentiel / Study of a trithermal system with a new thermal compression process of the working fluid, for the residential heating

Ibsaine, Rabah 12 November 2015 (has links)
L’innovation technologique dans les filières énergétiques est une manière pertinente de réaliser des économies d’énergie et de répondre aux préoccupations environnementales. Le chauffage représente la principale consommation d’énergie dans le secteur de l’habitat en France et contribue fortement aux rejets de gaz à effet de serre. Un nouveau conceptde compresseur thermique a été développé par la société boostHEAT. Il est destiné à remplacer le compresseur mécanique conventionnel d’un système de pompe à chaleur au CO2 pour former un système “tritherme”. Ce compresseur thermique est constitué d’un cylindre muni d’un piston déplaceur, d’un échangeur réchauffeur, d’un régénérateur etd’un échangeur refroidisseur. Le réchauffeur est connecté à la partie chaude du cylindre d’une part, et au régénérateur, d’autre part. Le refroidisseur est connecté au régénérateur d’une part, et à la partie froide du cylindre d’autre part. Cette dernière est connectée à la branche basse pression (évaporateur) de la pompe à chaleur par un clapet d’admission, età la branche haute pression de la pompe à chaleur (échangeur haute pression) par l’intermédiaire d’un clapet de refoulement. Après avoir exposé le principe de fonctionnement du compresseur thermique, la conception de ses principaux composants et le banc d’essai expérimental, nous présentons un modèle détaillé permettant de décrire le fonctionnementdu compresseur thermique et d’étudier l’influence de différents paramètres sur ses performances énergétiques. Le modèle développé est validé par comparaison avec les résultats de l’expérience. Enfin, le cycle de pompe à chaleur au CO2 supercritique, muni de deux étages du compresseur thermique, est étudié et optimisé. / Technological innovation in energy systems is a good way to improve energy efficiencies and respond to environmental preoccupations. Heating accounts for the primary energy consumption in the housing sector and contributes significantly to emissions of greenhouse gas. A new concept of thermal compressor was developed by the boostHEAT company. It is intended to replace the conventional mechanical compressor of a CO2 heat pump system to form a "trithermal" system.This compressor is made up of a cylinder with a displacer piston, a heater, a regenerator and a cooler. The heater is connected to the hot part of the cylinder on the one hand and to the regenerator on the other hand. The cooler is connected to the regenerator on the one hand and to the cold part of the cylinder on the other hand. The cold part of the cylinder is connected to the low pressure branch of the heat pump (evaporator) through an automatic inlet valve, and to the high pressure branch of the heat pump (gas cooler) through an automatic exhaust valve. After explaining the operating principle of the thermal compressor, the design of its main components and the experimental test bench, we present a detailed model for describing the operation of the thermal compressor. This model allows the study of the influence of several parameters on the energy performance of the thermal compressor. The model is then validated by comparison with experimental results. Finally, the supercritical CO2 heat pump cycle with two stages of thermal compressor is studied and optimized.
186

Contribution à l’évaluation biogéochimique des impacts liés à l’exploitation géothermique des aquifères superficiels : expérimentations et simulations à l’échelle d’un pilote et d’installations réelles / Contribution to the biogeochemical evaluation of the impacts related to the geothermic exploitation of the near-surface aquifers : experiments and simulations on a pilot and real installation scale

Garnier, Frédéric 25 October 2012 (has links)
Pour la climatisation de bâtiments ou d’installations industrielles, les nappes d’eaux superficielles représentent une source de frigories très convoitée. Leurs exploitations intensives depuis plusieurs dizaines d’années conjuguées au redéploiement de la filière géothermique ces dernières années, soulèvent des préoccupations quant à la préservation des ressources en eau. Dans ce contexte, la présente étude vise à évaluer l’impact de variations locales de température sur la qualité physico-chimique et microbiologique des eaux souterraines sur la base (i) de suivis in-situ au niveau de 3 installations réelles exploitant les nappes d’eaux superficielles et, (ii) d’expérimentations sur un pilote (BIOTHERMEX) permettant de reproduire, en conditions parfaitement maitrisées, l’effet de la propagation d’un panache thermique dans un modèle réduit d’aquifère. Dans la gamme de température relevée sur site, les principaux résultats obtenus montrent que les impacts thermiques sont circonscrits au voisinage immédiat de l’installation, pouvant altérer jusqu’à plus d’une dizaine de degrés la sténothermie des nappes. Le suivi des paramètres physico-chimiques n’ont pas fait apparaitre de perturbations significatives sur la période de surveillance, constat étayé par des modélisations hydrogéochimiques. En revanche, une influence significative a été relevée au niveau des principaux descripteurs microbiologiques (activité, diversité de la microflore totale). Enfin, les expériences menées à l’échelle du laboratoire ont permis d’appréhender finement le comportement réactionnel du système et de définir une température de réinjection critique, au-delà de laquelle des désordres potentiels sont attendus. / The use of shallow groundwater as heat source for heat pump is very coveted for air-conditioning of building or industrial facilities. Their intensive use during many years combined with the redeployment of the geothermal industry these last years, raise concerns about the safeguarding of the water resources. In such a context, the present study aims to evaluate the impact of local variations of temperature on the physicochemical and microbiological quality of groundwater systems on the basis of (I) field investigation and, (II) experiments on a pilot (named BIOTHERMEX) making it possible to reproduce, in perfectly supervised conditions, the effect of the propagation of a thermal plume in a reduced aquifer model. Within the temperature recorded on site, principal outcomes showed that thermal impacts are confined in the immediate vicinity of the installation, and were able to deteriorate, up to about ten degrees, the stenothermy of the groundwater systems. The evolution of the physicochemical parameters did not reveal any significant disturbances over the monitoring period, this being also predicted by hydrogeochemical modeling. On the other hand, a significant influence was raised about some microbiological indicators-descriptors (namely activity, diversity of the total microflora). Lastly, the experiments undertaken on the laboratory scale made it possible to finely apprehend the reactional behavior of the system and to define a critical temperature of re-injection beyond which, potential disorders are expected.
187

Etude numérique des performances thermiques d'un habitat bioclimatique / Numerical study of the thermal performances of a bioclimatic habitat

Camara, Yacouba 17 December 2018 (has links)
Cette recherche est basée sur une étude numérique de performances thermiques d'un habitat bioclimatique. Dans cette étude, nous avons considérés deux habitats bioclimatiques, l'un concernant un habitat classique de toiture en tôles d'aluminium, de faux plafond en laine de bois et le second, un habitat intégrant du panneau de MCP qui sépare la toiture en tuiles transparentes de l'enceinte parallélépipédique. Les équations de transfert de chaleur dans l'habitat sont basées sur la méthode nodale et sont déduites d'un bilan thermique établi pour les différents composants de l'habitat. Les transferts de chaleur dans l'unité de stockage sont axées sur la méthode enthalpique et purement conductif. Elles sont résolues par une méthode implicite aux différences finies et les algorithmes de Gauss et de Thomas. Nous avons analysé l'influence de certains paramètres tels que : le flux solaire, l'épaisseur du mur, la température maximale et minimale, et le taux de renouvellement d'air sur les distributions de températures des composants de l'habitat et de l'unité de stockage, les efficacités thermiques de stockage et de déstockage de l'unité de stockage. Une modélisation des phénomènes de transfert de chaleur dans l'habitat et dans l'unité de stockage est présentée, complétée par une simulation du fonctionnement du système basée sur les notions de journée type à travers les données météorologiques de la région de Ouagadougou et terminé par une analyse technico-économique. / This research is based on a numerical study of thermal performances of a bioclimatic habitat. In this study, we considered two bioclimatic habitats, one concerning a conventional aluminum roofing habitat, wood-wool false ceilings, and the second, a habitat incorporating a MCP panel that separates the roof into tiles transparent parallelepipedic enclosure. The heat transfer equations in the habitat are based on the nodal method and are deduced from a heat balance established for the different components of the habitat. The heat transfers in the storage unit are focused on the enthalpy and purely conductive method. They are solved by an implicit finite difference method and the Gauss and Thomas algorithms. We analyzed the influence of certain parameters such as: solar flux, wall thickness, maximum and minimum temperature, and the rate of air exchange on the temperature distributions of the components of the habitat and water. Storage unit, the thermal efficiencies of storage and retrieval of the storage unit. A modeling of the heat transfer phenomena in the habitat and in the storage unit is presented, completed by a simulation of the functioning of the system based on the notions of typical day through the meteorological data of the region of Ouagadougou and ended by a technical and economic analysis.
188

Pervaporation de composés purs : approche expérimentale du couplage entre transfert de matière et transfert de chaleur / Pervaporation of pure compounds : experimental approach of the coupling between mass and heat transfer

Toudji, Sid-Ali Amine 10 April 2018 (has links)
L'objectif de ce travail est l'étude du procédé de pervaporation et plus particulièrement la compréhension des mécanismes de transfert de masse et de chaleur dans une membrane en polymère qualifiée de dense. Une meilleures compréhension des mécanismes permettrait de lever les verrous limitant le développement de ce procédé, comme les faibles flux de matière ainsi que l'origine et la quantité de chaleur nécessaire au transfert à travers la membrane. Pour cela, nous avons développé un dispositif expérimental qui permet de mesurer en simultané les densités de flux de matière et de chaleur. La configuration frontale statique de perméation du dispositif mis en place donne accès au profil de température du liquide d'alimentation. Ces données de température ont permis de calculer les densités de flux de chaleur engagées durant les expériences de pervaporation grâce à un calcul par méthode inverse couplé à une simulation STAR CCM+. La densité de flux de matière est mesurée par une nouvelle méthode. La nouvelle méthode utilise un capteur de pression situé dans le réservoir d'alimentation permettant de mesurer en continu la densité de flux de matière synchronisée avec la mesure des températures. Afin de simplifier au maximum les contraintes expérimentales, nous nous sommes restreints à la perméation de composés purs. La corrélation des deux flux mesurés nous a conduit à observer que la quantité de chaleur prise au fluide en amont pour pervaporer une unité de masse de liquide pur est inférieure à la quantité de chaleur nécessaire pour vaporiser ce même liquide. Elle représente 50 % de celle-ci dans le cas de l’eau et seulement 25 % dans le cas de l’éthanol. / The aim of this work is to study the pervaporation process and specifically to understand the mass and heat transport mechanisms in a dense polymeric membrane. A better understanding of these mechanisms would make it possible to improve the limiting parameters for the development of this process, such as the low mass fluxes as well as the origin and the quantity of heat required for transport through the membrane. In order to answer these questions, we have developed an experimental setup that allows simultaneous measurement of mass flux and heat flux density. The dead-end permeation of the setup developed gives access to the temperature profile of the liquid feed. These temperature data make possible the estimation of the heat flux densities engaged during the pervaporation experiments by means of an inverse computation coupled with a STAR CCM + simulation. The mass flux is measured by a new method in addition to the gravimetric method used as a reference. The new method uses a pressure sensor located in the feed tank to continuously measure the mass flux with 1Hz raw acquisition frequency synchronized with the temperature measurement. In order to simplify the experimental constraints, we applied only permeation of pure liquids. The correlation of the two fluxes (mass and heat density) measured led us to observe that the amount of heat taken to the feed side to pervaporate a unit mass of pure liquid is less than the amount of heat required to vaporize the same liquid. It represents 50% of it in the case of water and only 25% in the case of the ethanol.
189

Etude thermohydraulique expérimentale et numérique d'une boucle d'hélium supercritique en convection forcée soumise à des pulses périodiques de chaleur / Experimental and numerical thermohydraulics study of a forced flow supercritical helium loop under periodical heat loads

Lagier, Benjamin 11 March 2014 (has links)
Les futurs réacteurs expérimentaux comme ITER ou JT-60SA réaliseront des réactions de fusion thermonucléaire au sein de plasmas de plusieurs millions de degrés. Le confinement de la réaction au centre de la chambre est assuré par des champs magnétiques très intenses générés par des aimants supraconducteurs. Ces bobines sont refroidies à 4.4 K via une circulation forcée d’hélium supercritique. Le fonctionnement cyclique des machines engendre des charges thermiques pulsées qui devront être absorbées par les réfrigérateurs de plusieurs mégawatts de puissances électriques. L’expérience HELIOS, construite au CEA Grenoble, est une maquette à échelle réduite du système de distribution d’hélium du tokamak JT-60SA constituée d’un bain d’hélium à saturation et d’une boucle en hélium supercritique. Les travaux de thèse présentés ici explorent les possibilités d’HELIOS afin de réaliser les études expérimentale et numérique de trois stratégies de lissage de charges thermiques : l’utilisation du bain saturé en tant que volant thermique ouvert, la variation de la vitesse du circulateur et l’utilisation de la vanne de by-pass de la charge thermique. Le modèle EcosimPro développé ici rend bien compte des phénomènes de couplage transitoire entre le dépôt d’énergie, la montée en pression et en température de la boucle de circulation, de même que le couplage entre la boucle de circulation et le bain saturé. Des contrôles avancés ont été testés numériquement puis validés expérimentalement pour améliorer la stabilité du réfrigérateur et optimiser la puissance de réfrigération. / Future fusion reactor devices such as ITER or JT-60SA will produce thermonuclear fusion reaction inplasmas at several millions of degrees. The confinement in the center of the chamber is achieved byvery intense magnetic fields generated by superconducting magnets. These coils have to be cooleddown to 4.4 K through a forced flow of supercritical helium. The cyclic behavior of the machinesleads to pulsed thermal heat loads which will have to be handled by the refrigerator.The HELIOS experiment built in CEA Grenoble is a scaled down model of the helium distributionsystem of the tokamak JT-60SA composed of a saturated helium bath and a supercritical helium loop.The thesis work explores HELIOS capabilities for experimental and numerical investigations on threeheat load smoothing strategies: the use of the saturated helium bath as an open thermal buffer, therotation speed variation of the cold circulator and the bypassing of the heated section. Thedeveloped model describes well the physical evolutions of the helium loop (pressure, temperature,mass flow) submitted to heat loads observed during experiments. Advanced controls have beentested and validated to improve the stability of the refrigerator and to optimize the refrigerationpower.
190

Hygrothermique du bâtiment : expérimentation sur une maison à ossature bois en conditions climatiques naturelles et modélisation numérique

Piot, Amandine 09 November 2009 (has links) (PDF)
Les maisons à ossature bois sont des structures particulièrement sensibles aux flux d'air et d'humidité. Des études récentes ont montré que de telles sollicitations peuvent dégrader la qualité et la durabilité d'un bâtiment. Après avoir décrit la physique des transferts couplés d'énergie et de masse, nous présentons le support expérimental de cette étude : une maison à ossature bois, de dimensions représentatives d'une construction réelle, qui a été construite sur une plate-forme d'exposition en extérieur. Cette cellule expérimentale a été instrumentée afin d'étudier le comportement hygrothermique des parois et de la pièce principale. Les données météorologiques sont relevées sur le site même. Plusieurs configurations ont été étudiées dans le cadre de ces travaux : parois avec et sans pare-vapeur ; climat interne avec ou sans chauffage, humidification ou ventilation. Des mesures de perméabilité à l'air de la cellule ont également été effectuées. Enfin, une campagne de détermination des caractéristiques des matériaux employés a été lancée. En parallèle de cette expérimentation, un modèle numérique de la cellule a été développé, basé sur le modèle existant HAM-tools. Le modèle est utilisé sur plusieurs séquences expérimentales. L'étude de la validité du modèle s'est faite par étapes : d'abord la paroi seule, puis couplée avec la zone, enfin le modèle de bardage. Nous présentons les résultats de la comparaison entre les mesures et les simulations numériques, et discutons de la validité du modèle et des limites imposées par l'expérimentation. Cette étude a notamment permis de mettre en évidence l'effet de sollicitations thermiques sur le comportement hygrique d'une paroi comportant un matériau hygroscopique, et montré la capacité du modèle développé à le décrire.

Page generated in 0.0384 seconds