• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 17
  • 17
  • 17
  • 13
  • 11
  • 11
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Preparação, caracterização e aplicações eletroanalíticas de silsesquioxanos e dendrímeros modificados suportados na superfície da sílica gel

Gabriel Junior, Suelino [UNESP] 01 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:25:32Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-10-01Bitstream added on 2014-06-13T20:14:08Z : No. of bitstreams: 1 gabrieljunior_s_me_ilha.pdf: 1458989 bytes, checksum: 61fbe8b93b56e59134558e478f7ab91e (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho descreve a preparação, caracterização e as aplicações eletroanalíticas de silsesquioxanos e dendrímeros modificados suportados na superfície da sílica gel. A primeira etapa consistiu em ancorar o silsesquioxano ([H2N(CH2)3]8Si8O12) e o dendrímero Hexadecaamino Poli(propileno)imina (DAB-Am- 16) na superfície da 3-cloropropil sílica gel. Os materiais obtidos, SAC e SD, respectivamente, foram caracterizados pelas técnicas de Infravermelho (FTIR), RMN 29Si e 13C no estado sólido e Energia Dispersiva de Raios-X (EDX). A segunda etapa foi interagir o SAC e o SD com íons de Cu2+ e Ni2+ e posterior complexação com substâncias eletroativas, tais como: ferricianeto de potássio e nitroprussiato de sódio formando, dessa forma, os complexos binucleares: CuHCFSAC, NiHCFSAC, CuNPSAC, CuHCFSD, NiHCFSD e CuNPSD que foram caracterizados por Infravermelho (FTIR) e voltametria cíclica (VC). Os espectros na região do Infravermelho dos materiais supracitados exibiram freqüências próximas ou iguais a 2090 cm-1, atribuídas ao estiramento n(C N) característico do hexacianoferrato e nitroprussiato formados na superfície da SAC e SD. Utilizou-se estes materiais na construção do eletrodo de pasta de grafite os quais foram testados na oxidação eletrocatalítica de substâncias biologicamente importantes tais como a dipirona sódica e nitrito de sódio após um rigoroso estudo sobre o comportamento voltamétrico. O eletrodo de pasta de grafite contendo o CuHCFSAC exibiu dois pares redox com potenciais médios (Em) de: (Em)1= 0,29 V e (Em)2= 0,72 V vs Ag/AgCl (KCl =1.0 molL-1; v = 20 mV s-1) ambos atribuídos aos processos redox Cu(I)/Cu(II) e [Fe(II)(CN)6]4- / [Fe(III)(CN)6]3-, respectivamente, valores estes bem próximos para o CuHCFSD. Os eletrodos de NiHCFSAC e NiHCFSD exibiram... / This work describes the preparation, characterization and electroanalytical properties of modified silsesquioxanes and dendrimers supported onto the silica gel surface. The first step was to anchor the silsesquioxane [(H2N(CH2)3] 8Si8O12) and dendrimer Hexadecaamino Poly(propylene)imine (DAB-Am-16) onto the 3-chloropropyl silica gel surface. The materials obtained, SAC and SD, respectively, were characterized by infrared (FTIR), 29Si NMR and 13C solid state and Energy Dispersive X-ray (EDX). The second step was interact the SAC and SD with Cu2+ and Ni2+ ions and subsequent complexation with electroactive substances, such as: ferricyanide of potassium and sodium nitroprusside forming binuclear complexes: CuHCFSAC, NiHCFSAC, CuNPSAC, CuHCFSD, NiHCFSD and CuNPSD which were characterized by Infrared (FTIR) and cyclic voltammetry (CV). The spectra in the infrared region of the above materials exhibited frequencies near or equal to 2090 cm-1 assigned to stretching n(C N) characteristic of nitroprusside and hexacyanoferrate formed onto the SD and SAC surface. We used these materials in the construction of carbon paste electrode which were tested in the electrocatalytic oxidation of biologically important substances such as sodium dipyrone and sodium nitrite after a rigorous study about voltammetric behavior. The graphite paste electrode containing CuHCFSAC exhibited two redox couples with midpoint potentials (Em) of: (Em)1 = 0.29 V and (Em)2 = 0.72 V vs. Ag/AgCl (KCl = 1.0 mol L-1, v = 20 mV s-1) both assigned to the redox processes Cu(I)/Cu(II) and [Fe(II)(CN)6]4- / [Fe(III)(CN)6]-3, respectively, values very near to the CuHCFSD. The electrodes of NiHCFSAC and NiHCFSD each exhibited two redox couples with midpoint potentials (Em): (Em)1 = 0.29 V and (Em)2 = 0.51 V vs Ag/AgCl (KCl = 1.0 mol L-1, v = 20 mV s- 1) both... (Summary complete electronic access click below)
12

Desenvolvimento de sensores voltamétricos e piezelétricos modificados quimicamente com cucurbiturilas para análises de cocaína em amostras de interesse forense / Development of voltammetric and piezoelectric sensors chemically modified with cucurbiturils for analysis of cocaine in samples of forensic interest.

Matheus Manoel Teles de Menezes 14 November 2014 (has links)
Considerando a relevância dos trabalhos onde se utiliza eletrodos quimicamente modificados e o pequeno número de estudos envolvendo cocaína e seus interferentes (cafeína, teobromina e lidocaína), por técnicas eletroquímicas ou piezelétricas, este estudo tem como objetivo o desenvolvimento de eletrodos de ouro e platina quimicamente modificados com compostos da classe das cucurbiturilas (CB[5], CB[6] e CB[7]) para a detecção de cocaína. A técnica de microbalança de cristal de quartzo foi empregada a fim de se estudar cocaína padrão e seus interferentes, em fase gasosa. Os eletrodos de ouro foram quimicamente modificados com cucurbiturilas e o modificador CB[6] apresentou os melhores resultados. Medidas por voltametria cíclica foram realizadas utilizando-se um potenciostato Autolab III acoplado a um computador, com eletrodo de ouro e platina atuando como eletrodo de trabalho, Ag/AgCl como eletrodo de referência e eletrodo espiral de platina como eletrodo auxiliar, com velocidade de varredura de 0,1 V.s-1 (100 mV.s-1). Os parâmetros voltamétricos foram otimizados para tornar as análises mais rápidas e sensíveis sem perda de qualidade ou intensidade do sinal voltamétrico. O eletrodo de platina quimicamente modificado com filme de cucurbit[6]urila apresentou aumento da corrente de pico catódica quando estudado frente à cocaína, teobromina e lidocaína. Análises com eletrodo de platina sem modificador químico apresentaram limite de detecção de 4,14.10-6 mol.L-1 e limite de quantificação de 1,38.10-5 mol.L-1 , para a cocaína, e na presença do modificador químico CB[6] apresentou limite de detecção de 1,36.10-6 mol.L-1 e limite de quantificação de 4,54.10-6 mol.L-1 . Eletrodos de ouro com ou sem a presença de modificadores químicos não apresentaram sinal para nenhum analito. / Considering the importance of chemically modified electrodes and the small amount of the cocaine study and their interfering (caffeine, theobromine and lidocaine) using electrochemical and piezoelectric techniques, this study aims to investigate the development of the gold and platinum electrodes chemically modified by cucurbiturils (CB[5], CB[6] and, CB[7]) in order to detect cocaine. The Quartz Crystal Microbalance technique was employed in order to study in gas phase the standard samples of cocaine and their interfering. Gold electrode was chemically modified with cucurbiturils films and the CB[6] modifier showed the best results. The cyclic voltammetric measurements were performed using a Autolab III potentiostat coupled to a computer, being gold and platinum as the working electrode, Ag/AgCl as the reference electrode and platinum wire as counter electrode, using a scan rate of 0,1 V.s-1 (100 mV.s-1). The voltammetric parameters were optimized in order to make the analysis faster and more sensitive without loss of intensity and quality of the voltammetric signal. The platinum electrode modified by cucurbit[6]uril film showed an increase of cathodic current peak when electrode was exposed to cocaine, theobromine and lidocaine. Analysis employed platinum working electrode without chemical modifier showed a detection limit of 4.14 . 10-6 mol.L-1 and quantification limit of 1.38 . 10-5 mol.L-1 for cocaine and with chemical modifier CB[6] showed a detection limit of 1.36 . 10-6 mol.L-1 and quantification limit of 4.54 . 10-6 mol.L-1 . Gold electrodes with or without chemical modifiers showed no response for any analyte.
13

Desenvolvimento de um sistema eletroquímico de análise por injeção em fluxo para detecção de cocaína / Development of an Electrochemical Flow Injection Analysis system for Detection of Cocaine

Laura Siqueira de Oliveira 17 January 2012 (has links)
O aumento nos índices de criminalidade, na maioria das vezes decorrente de atividades ligadas ao tráfico de drogas, afeta drasticamente a qualidade de vida do ser humano. A análise instrumental de entorpecentes é realizada comumente por métodos cromatográficos, oferecendo limites de detecção (LDs) em torno de 1 ng mL-1. As técnicas analíticas como voltametria, amperometria, potenciometria, dentre outras, assemelham-se às técnicas convencionais de análise, pois além de se mostrarem sensíveis para a análise de traços de substâncias orgânicas e inorgânicas, oferecem vantagens operacionais como a compreensão de mecanismos pato-fisiológicos de várias drogas, dentre elas a cocaína e seus metabólitos. Os eletrodos quimicamente modificados (EQMs) com bases de Schiff (grupos funcionais que contém uma ligação dupla carbono-nitrogênio com o átomo de nitrogênio conectado a um grupo arila ou alquila) desenvolvidos para a determinação de cocaína em amostras de interesse forense podem ser empregados em situação de análise por injeção em fluxo (FIA). Cuja metodologia consiste na inserção de uma alíquota de amostra em um fluido carregador que a transporta do ponto de injeção até a unidade de detecção. Atualmente a análise de cocaína está limitada à dosagem posterior de amostras apreendidas, uma vez que não há nenhum dispositivo portátil para a detecção da mesma em local de crime. Assim, este projeto visa desenvolver uma metodologia voltamétrica, por meio de eletrodos quimicamente modificados com bases de Schiff, e da aplicação dos mesmos em FIA para a detecção de cocaína em amostras de interesse forense. / The increase in crime occurrences, mostly due to activities linked to drug trafficking, dramatically affects the quality of human life. The instrumental analysis of drugs is commonly performed by chromatographic methods, offering limits of detection (LD) around 1 ng mL-1. Analytical techniques such as voltammetry, amperometry, potentiometry, among others, are similar to conventional analysis techniques, as well as prove sensitive for trace analysis of organic and inorganic substances, provide operational advantages as the understanding of pathophysiological mechanisms of several drugs, among them cocaine and its metabolites. The chemically modified electrodes (CMEs) with Schiff bases (functional groups containing a carbon-nitrogen double bond with the nitrogen atom attached to an alkyl or aryl group) developed for the determination of cocaine in samples of forensic interest can be used in situation of flow injection analysis (FIA). The methodology consists of inserting a sample rate of a carrier fluid that carries the point of injection to the detection unit. The analysis is limited to the dosage cocaine samples seized previously, since there is no portable device for detection in the same scene. Thus, this project aims to develop a voltammetric methodology, by means of chemically modified electrodes with Schiff bases, and applying them in the FIA for the detection of cocaine in samples of forensic interest.
14

Eletrodos quimicamente modificados com Poli (benzil viologênio): comportamento eletroquímico de fármacos nitroderivados. / Chemically modified electrodes with Poly (benzyl viologen): electrochemical behavior of nitro derivative drugs.

Laíla Aparecida Deliberto 15 March 2013 (has links)
Na área da saúde, destacam-se alguns fármacos amplamente administrados, os quais possuem grupamentos nitro em suas moléculas, como o Clonazepam (CNZ), Nitrazepam (NTZ) e Nimesulida (Nimes). O CNZ e o NTZ são utilizados ilicitamente em coquetéis entorpecentes, fragilizando vítimas. A Nimes é anti-inflamatório amplamente administrado e frequentemente usado sem prescrição médica. As metodologias de detecção e quantificação destes fármacos são, na sua maioria, dispendiosas, desenvolvidas por HPLC, GC, etc. Poucos trabalhos utilizam determinação eletroanalítica e dentre eles, menos ainda utilizam eletrodos quimicamente modificados (EQMs). Os EQMs melhoram a seletividade e sensibilidade das análises. Dentre as formas de modificação, a metodologia de filmes poliméricos é muito versátil e possibilita o desenvolvimento de eletrodos específicos. Uma classe importante de polímeros é a dos derivados de viologênio, como o Poli (benzil viologênio) (PBV). Este polímero é empregado com diferentes finalidades. Possui três estados de oxidação, um deles; o PBV+ atua como mediador redox. E, a partir de experimentos prévios em nosso laboratório demonstrou ainda a possibilidade de atuar na redução de nitrocompostos. Neste sentido, este trabalho determinou as melhores condições experimentais para obtenção de um EQM com o PBV para seu emprego em análise e quantificação de fármacos nitroderivados (CNZ, NTZ e Nimes), bem como em amostras comerciais, utilizando a técnica de voltametria cíclica. Este trabalho contribuiu para o desenvolvimento de uma metodologia eficaz de modificação do eletrodo de carbono vítreo (CV) com o PBV sintetizado. Este método garantiu o controle da cobertura e a linearidade nas análises. Assim, o método foi padronizado com a aplicação de eletrólise por 30 s durante o terceiro ciclo em -0,4 V. A varredura adotada foi 50 mV s-1 de 0 a -0,8 V. Esse padrão forneceu de 2,0 a 3,0 nmol cm-2 de cobertura. O eletrodo CV-PBV não apresentou dificuldades na transferência de carga da superfície do eletrodo para o polímero, apesar do valor de k = 5,2 s-1 em tampão fosfato 0,1 mol L-1 pH 7,0. O valor do coeficiente difusional de cada fármaco foi determinado em tampão fosfato 0,1 mol L-1 pH 7,0. Os estudos de redução dos fármacos em diferentes pHs estão de acordo com o mecanismo descrito na literatura. Além disso, os resultados indicam que o eletrodo modificado diminui a influência do pH sobre a redução dos fármacos. As quantificações dos fármacos foram feitas por curvas padrões com os eletrodos CV e Au, polidos e modificados. As correntes foram lineares até a concentração de 120 mol L-1. A modificação do eletrodo de CV com o PBV diminuiu, no mínimo, em aprox. 80 mV o potencial de redução dos fármacos em pH 7,0 em relação ao eletrodo de CV polido. A exceção foi o eletrodo de ouro modificado (Au-PBV) na análise de Nimes. Pode-se ainda, atribuir à modificação do eletrodo com o PBV o aumento da sensibilidade das análises em comparação aos respectivos eletrodos polidos. Somente a determinação do NTZ não apresentou o mesmo efeito. O eletrodo CV-PBV foi empregado com sucesso na quantificação dos fármacos (NTZ, CNZ e Nimes) em amostras comerciais de Rivotril®, Sonebon® e Nimesulida - medicamento genérico. As quantificações apresentaram aproximadamente 100% de recuperação. A normalização das diferentes análises pelos valores das coberturas dos eletrodos mostrou uma curva analítica com boa correlação linear. Finalmente, os resultados apresentados neste trabalho sugerem a possibilidade de desenvolver eletrodos descartáveis. Estes eletrodos podem ser empregados na análise de substâncias utilizadas de forma ilícitas, neste caso, o coquetel chamado Boa noite Cinderela, para uso da perícia forense em análise amperométrica, no próprio local investigado. Estes eletrodos também podem ser aplicados nas indústrias farmacêuticas, nos setores de controle de qualidade de fármacos e medicamentos. / In health care, broadly administered drugs can be highlighted, which possess nitro group moieties within their molecules, such as the Clonazepam (CNZ), Nitrazepam (NTZ), and Nimesulide (Nimes). CNZ and NTZ are illicitly administered as part of narcotics drinks, weakening their victims. Nimes is an anti-inflammatory drug widely administered and often used in self-medication. Detection and quantification methods of these drugs are in the majority of cases costly and involve techniques such as HPLC, gas chromatography, etc. Only few studies have made use of electroanalytical determination, and among them, even fewer have made use of chemically modified electrodes (CME). CMEs improve selectivity and sensitivity of analysis. Among of modification methods, polymeric films are very versatile and make possible the development of specific electrodes. An important type of polymers comprise Viologen derivatives, such as Poly (benzyl viologen) (PBV). This polymer is used serving different purposes. This polymer has three oxidation states; one of them, PBV+, acts as a redox mediator. Also in addition, our group has provided evidence for the possibility of PBV+ to act reducing nitro compounds. In this way, in the present work it was determined the best experimental conditions for developing CME with PBV for further application in analysis and quantification of nitro derivative drugs (CNZ, NTZ and Nimes), as well as commercial samples, through the use of cyclic voltammetry technique. This work has contributed to the development of an effective methodology for the modification of glassy carbon (GC) electrodes with synthesized PBV. This method guaranteed the control of coverage and the linearity of the analysis. In this way, this method was standardized with a potential hold during the third cycle of about -0.4V for 30 sec. Scan rate of potential was 50 mV s-1, from 0 to -0.8 V. This method provided a coverage 2.0 to 3.0 nmol cm-2. The electrode GC-PBV did not show difficulties to charge transfer from the electrode surface to polymer, although the value of k was 5.2 s-1 in 0.1 mol L-1 phosphate buffer solution, pH 7.0. The difusional coefficient value of each drug was determined in 0.1 mol L-1 phosphate buffer solution, pH 7.0. Reduction studies of drugs in different pHs were in agreement with mechanisms described in the literature. Furthermore, results suggest that modified electrode decreased pH influence regarding drug reduction. Drug quantification was achieved from standard curves using GC and gold electrodes, polished and modified. Currents were linear up to 120 mol L-1. GC electrode modification with PBV decreased, at least, in approximately 80 mV, the drug potential reduction at pH 7.0 compared to respective polished electrode. The exception was found for gold modified electrode during Nimes analysis. It can be also attributed to modification with PBV the increase of analysis sensitivity when compared to respective polished electrodes. Only NTZ determination did not show the same effect. The GC-PBV was successfully employed for drug quantification (NTZ, CNZ and Nimes) from commercial samples, such as Rivotril®, Sonebon® and Nimesulide generic medicine. Drug quantification exhibited recovery close to 100%. Standardization of different analysis by electrode coverage value showed good linear correlation. Finally, results suggest the possibility to develop disposable electrodes. These electrodes can be employed to illicit substance analysis, in the present case, the narcotic drinks known in Brazil as Boa noite Cinderela, in addition to use in forensics during amperometic analysis at the site of investigation. Also, such electrodes could be used in pharmaceutical industries, for drug and medicine quality control.
15

Desenvolvimento de métodos voltamétricos para a quantificação de LSD utilizando-se o eletrodo de pasta de carbono modificado com complexo de base de Schiff / Development of voltammetric methods for the quantification of LSD using a carbon paste electrode modified by a Schiff base complex

Maria Fernanda Muzetti Ribeiro 29 October 2015 (has links)
Nos últimos anos, vários métodos eletroanalíticos foram desenvolvidos a fim de tornarem mais práticas e acessíveis às análises químicas de substâncias entorpecentes realizadas pela polícia científica. Com a sensibilidade e seletividade compatíveis com as dos métodos instrumentais convencionais, é a portabilidade da técnica eletroanalítica que se sobressai e tem apresentado grande potencial para tais aplicações. O uso de complexos metálicos com as bases de Schiff como modificadores do eletrodo de trabalho, tornou ainda mais promissora a utilização destes métodos para a detecção e quantificação de entorpecentes. Os eletrodos de pasta de carbono também contribuem para a praticidade da eletroanalítica, uma vez que são produzidos de forma simples e barata. Desta forma, neste projeto foram desenvolvidos métodos voltamétricos para a quantificação da dietilamida do ácido lisérgico (LSD), utilizando-se o eletrodo de pasta de carbono modificado com o complexo [UO2(Ac-ophen)]·H2O. A aplicação do KCl como eletrólito suporte, em solução aquosa, diferencia estes métodos do encontrado na literatura. Nas análises, foram empregadas as técnicas de voltametria cíclica, onda quadrada e de pulso diferencial. A linearidade no aumento da corrente frente às variações da concentração do LSD possibilitou a obtenção das curvas analíticas com desvio padrão e limites de detecção e quantificação de 2,45, 0,62 e 1,02 mol L-1, respectivamente, como melhores resultados. As análises de recuperação das amostras, 103 e 108%, demostra a possibilidade da utilização destas no âmbito forense. / The development of electroanalytical methods for forensic science has been growing in recent years by the fact of their practicality and low cost. Once sensibility and selectivity values are compatible to conventional methods, as chromatography and spectrometry, the portability of this system consists on interesting advantages. The simple modification of the carbon paste working electrode with Schiff bases complexes became even more promising to use this method for the detection and quantification of narcotics. The carbon paste electrode itself contributes for the practicality of the analyses, once it is made of simple carbon powder, which can be disposable. This project aimed to develop voltammetric methods for the quantification of the lysergic acid diethylamide (LSD) using a carbon paste electrode modified with the complex [UO2(Ac-ophen)]·H2O. The use of aqueous solution of KCl as supporting electrolyte characterizes a less pollutant methodology, differently of other methods that still use toxic solvents The combination of the differential pulse and square wave voltammetries with the modified carbon paste was crucial for the detection of trace levels of the LSD. The linear response in various concentrations of LSD results on analytical curves with standard deviation, detection, and quantification limits of 2,45, 0,62, 1,02 mol L-1, respectively. And the recovery values of 103 and 108 % indicates the possibility of using this method in the forensic science
16

Desenvolvimento e aplicação de eletrodos quimicamente modificados com hexacianoferratos dos metais Fe, Ni e Co / Development and application of chemically modified electrodes with hexacyanoferrate of Fe, Co and Ni

Carvalho, Sâmea Eulles Quixaba de 17 June 2011 (has links)
O presente trabalho descreve o uso de eletrodos de carbono vítreo como eletrodo-base para modificação com hexacianoferratos de Fe (FeHCF), Co (CoHCF) e Ni (NiHCF) por meio da adsorção destes complexos utilizando a técnica de voltametria cíclica. Os eletrodos quimicamente modificados (EQMs) preparados por este método apresentam características diferenciadas tais como robustez e estabilidade ao longo das medidas eletroquímicas, além de boas propriedades redox. Os EQMs com FeHCF e NiHCF foram avaliados em função da sua atividade eletrocatalítica para a reação de oxidação do Ácido Ascórbico em solução de KCl 0,1 mol L-1 (pH 6,6). O EQM com CoHCF foi avaliado nas mesmas condições dos outros filmes, porém não apresentou uma diminuição no sobrepotencial de oxidação do Ácido Ascórbico. Embora não tenha apresentado uma resposta semelhante aos EQMs com FeHCF e NiHCF, o EQM com CoHCF apresentou a melhor sensibilidade da resposta de corrente de pico quando comparado aos demais. A fim de proporcionar a renovação da superfície do eletrodo foi avaliada a utilização de eletrodos de pasta de carbono modificada com FeHCF, CoHCF ou NiHCF. Os parâmetros de composição da pasta, o eletrólito suporte e o pH foram avaliados utilizando o EPCM com FeHCF por meio da técnica de voltametria cíclica e os parâmetros otimizados foram aplicados no uso dos EPCM com CoHCF e NiHCF. Para avaliar a sensibilidade na deteccção da L-Cisteína, do Glifosato e da N-Acetilcisteína, os EPCMs modificados foram submetidos a estudos com a técnica de voltametria de onda quadrada. Todos os analitos apresentaram resposta eletroquímica em todos os EPCMs, porém as melhores respostas foram para o FeHCF na presença de L-Cisteína, CoHCF na presença de Glifosato e NiHCF na presença de N-Acetilcisteína. Na presença de 1 x 10-8 mol L-1 dos analitos os EPCMs com hexacianoferratos apresentaram um boa resposta eletroquímica, embora não tenha sido possível observar uma linearidade entre o aumento da concentração dos analitos propostos e a corrente de pico. Essa sensibilidade demonstrada pelos EPCMs na presença de moléculas com grupos funcionais, como ácidos carboxílicos, aminoácidos e tióis abre novas perspectivas para a análise direta de compostos de interesse clínico, farmacêutico e amostras de interesse ambiental. / This work describes the use of glassy carbon electrodes as the base for electrode modification with hexacyanoferrates of Fe (FeHCF), Co (CoHCF) and Ni (NiHCF) through adsorption of these complexes using cyclic voltammetry. The chemically modified electrodes (CMEs) prepared by this method have specific features such as robustness and stability along the electrochemical measurements, and good redox properties. The CME with FeHCF and NiHCF were evaluated take into accounting their electrocatalytic activity for oxidation reaction of Ascorbic Acid in KCl 0.1 mol L-1 (pH 6.6). The CME with CoHCF was evaluated under the same conditions, but did not show a decrease on the overpotential for Ascorbic Acid oxidation. Although the CME with CoHCF has not showed the same behavior presented by CMEs with FeHCF and NiHCF, the CME with CoHCF presented the best sensitivity in order to relationship between peak current and concentration of Ascorbic Acid when compared to CMEs with either. In order to provide the renewal of the electrode surface was evaluated the use of carbon paste electrodes (CPEs) modified with FeHCF, CoHCF and NiHCF. The CPE parameters such as composition, supporting electrolyte and pH were evaluated using the CPE with FeHCF by cyclic voltammetry and these optimized parameters were applied for CPEs with CoHCF and NiHCF. The studies about the sensitivity of the detection for L-Cysteine, glyphosate and N-acetylcysteine using the modified CPEs with hexacyanoferrates were performed by square wave voltammetry. All analytes showed electrochemical response at all CPEs, but the best electrochemical responses were obtained for FeHCF in the presence of L-Cysteine, CoHCF in the presence of glyphosate and NiHCF in the presence of N-acetylcysteine. The CPEs with hexacyanoferrates in the presence of 1 x 10-8 mol L-1 of L-Cysteine, glyphosate or N-acetylcysteine had showed a good electrochemical response, although were not possible to observe a linear correlation between the concentration of analytes and peak current. This sensitivity demonstrated by CPEs with hexacyanoferrates electrodes in presence of specific functional groups such as carboxylic acids, amino acids and thiols opens new perspectives for the direct analysis of compounds with clinical, pharmaceutical and environmental samples.
17

Desenvolvimento e aplicação de eletrodos quimicamente modificados com hexacianoferratos dos metais Fe, Ni e Co / Development and application of chemically modified electrodes with hexacyanoferrate of Fe, Co and Ni

Sâmea Eulles Quixaba de Carvalho 17 June 2011 (has links)
O presente trabalho descreve o uso de eletrodos de carbono vítreo como eletrodo-base para modificação com hexacianoferratos de Fe (FeHCF), Co (CoHCF) e Ni (NiHCF) por meio da adsorção destes complexos utilizando a técnica de voltametria cíclica. Os eletrodos quimicamente modificados (EQMs) preparados por este método apresentam características diferenciadas tais como robustez e estabilidade ao longo das medidas eletroquímicas, além de boas propriedades redox. Os EQMs com FeHCF e NiHCF foram avaliados em função da sua atividade eletrocatalítica para a reação de oxidação do Ácido Ascórbico em solução de KCl 0,1 mol L-1 (pH 6,6). O EQM com CoHCF foi avaliado nas mesmas condições dos outros filmes, porém não apresentou uma diminuição no sobrepotencial de oxidação do Ácido Ascórbico. Embora não tenha apresentado uma resposta semelhante aos EQMs com FeHCF e NiHCF, o EQM com CoHCF apresentou a melhor sensibilidade da resposta de corrente de pico quando comparado aos demais. A fim de proporcionar a renovação da superfície do eletrodo foi avaliada a utilização de eletrodos de pasta de carbono modificada com FeHCF, CoHCF ou NiHCF. Os parâmetros de composição da pasta, o eletrólito suporte e o pH foram avaliados utilizando o EPCM com FeHCF por meio da técnica de voltametria cíclica e os parâmetros otimizados foram aplicados no uso dos EPCM com CoHCF e NiHCF. Para avaliar a sensibilidade na deteccção da L-Cisteína, do Glifosato e da N-Acetilcisteína, os EPCMs modificados foram submetidos a estudos com a técnica de voltametria de onda quadrada. Todos os analitos apresentaram resposta eletroquímica em todos os EPCMs, porém as melhores respostas foram para o FeHCF na presença de L-Cisteína, CoHCF na presença de Glifosato e NiHCF na presença de N-Acetilcisteína. Na presença de 1 x 10-8 mol L-1 dos analitos os EPCMs com hexacianoferratos apresentaram um boa resposta eletroquímica, embora não tenha sido possível observar uma linearidade entre o aumento da concentração dos analitos propostos e a corrente de pico. Essa sensibilidade demonstrada pelos EPCMs na presença de moléculas com grupos funcionais, como ácidos carboxílicos, aminoácidos e tióis abre novas perspectivas para a análise direta de compostos de interesse clínico, farmacêutico e amostras de interesse ambiental. / This work describes the use of glassy carbon electrodes as the base for electrode modification with hexacyanoferrates of Fe (FeHCF), Co (CoHCF) and Ni (NiHCF) through adsorption of these complexes using cyclic voltammetry. The chemically modified electrodes (CMEs) prepared by this method have specific features such as robustness and stability along the electrochemical measurements, and good redox properties. The CME with FeHCF and NiHCF were evaluated take into accounting their electrocatalytic activity for oxidation reaction of Ascorbic Acid in KCl 0.1 mol L-1 (pH 6.6). The CME with CoHCF was evaluated under the same conditions, but did not show a decrease on the overpotential for Ascorbic Acid oxidation. Although the CME with CoHCF has not showed the same behavior presented by CMEs with FeHCF and NiHCF, the CME with CoHCF presented the best sensitivity in order to relationship between peak current and concentration of Ascorbic Acid when compared to CMEs with either. In order to provide the renewal of the electrode surface was evaluated the use of carbon paste electrodes (CPEs) modified with FeHCF, CoHCF and NiHCF. The CPE parameters such as composition, supporting electrolyte and pH were evaluated using the CPE with FeHCF by cyclic voltammetry and these optimized parameters were applied for CPEs with CoHCF and NiHCF. The studies about the sensitivity of the detection for L-Cysteine, glyphosate and N-acetylcysteine using the modified CPEs with hexacyanoferrates were performed by square wave voltammetry. All analytes showed electrochemical response at all CPEs, but the best electrochemical responses were obtained for FeHCF in the presence of L-Cysteine, CoHCF in the presence of glyphosate and NiHCF in the presence of N-acetylcysteine. The CPEs with hexacyanoferrates in the presence of 1 x 10-8 mol L-1 of L-Cysteine, glyphosate or N-acetylcysteine had showed a good electrochemical response, although were not possible to observe a linear correlation between the concentration of analytes and peak current. This sensitivity demonstrated by CPEs with hexacyanoferrates electrodes in presence of specific functional groups such as carboxylic acids, amino acids and thiols opens new perspectives for the direct analysis of compounds with clinical, pharmaceutical and environmental samples.

Page generated in 0.0757 seconds