• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 147
  • 5
  • 5
  • 5
  • 5
  • 4
  • 3
  • 1
  • 1
  • Tagged with
  • 154
  • 154
  • 100
  • 95
  • 65
  • 65
  • 47
  • 36
  • 34
  • 32
  • 30
  • 29
  • 28
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Resistência de união entre cimento resinoso auto-adesivo e dentina selada com adesivo auto condicionante / Bond strenght between self adhesive resin cement and sealed dentin with self etching adhesive

Leite, Murillo Martins 23 February 2017 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-03-09T17:27:02Z No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-10T10:54:28Z (GMT) No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-10T10:54:28Z (GMT). No. of bitstreams: 2 Dissertação - Murillo Martins Leite - 2017.pdf: 2935464 bytes, checksum: c2e541fcfb0b7d14e4119dc3da509cac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-02-23 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The daily practice of dentists evolves when restorative techniques lead to higher success rates and long-lasting in treatments associated to less invasive procedures. In this context, self-etching adhesives, self-adhesive cements and immediate dentin sealing are examples of modern materials and technique with an uprising popularity among clinicians. The objective of this study was to evaluate the influence of different surface treatment on the sealed dentin with self-etching adhesive on bond strength to a self-adhesive resin. The coronary portions of 90 bovine teeth, included in epoxy resin, were worn out for dentin exposure. The sample was randomly subdivided in six groups. In group C (control) the dentin was kept "fresh" while immediate dentin sealing with Clearfil SE Bond (Kuraray) were performed in the others five groups. After 24 hours of storage, the sealed dentin of the samples received different surface treatments: P group (prophylaxis with pumice); PA group (prophylaxis followed by etching with phosphoric acid); PAS group (prophylaxis, phosphoric acid and silanization); PASC group (prophylaxis, phosphoric acid, silanization and bonding layer of adhesive Clearfil SE Bond) and PAU group [prophylaxis, phosphoric acid and a universal adhesive layer Single Bond Universal (3M ESPE)]. After these protocols, U200 self-adhesive cement (3M ESPE) cylinders were bonded in all six groups, forming an average of 15 sample units per group. The samples were submitted to microshear bond strength test at 0.5mm/min for two storage times: 24 hours (T1) e 3 months (T2). Statistical analysis was carried out using Kruskal-Wallis test, presenting a significant difference between RUM values (p=0.0018) among groups, for 24 hours of storage, and PASC group presented values significantly higher than all other groups. For 3 months of storage, there was no significant difference (p=0,223) between the groups. It is possible to conclude that immediate dentin sealing produced microshear bond strength values similar to control group (as recommended by manufacturer, without immediate sealing), except for the group that associated prophylaxis, phosphoric acid, silane and Clearfil SE Bond that was significantly higher in 24 hours tests, without significant changes with 3 months of storage. / A odontologia evolui a partir de tratamentos que ofereçam alto índice de sucesso em comunhão com simplicidade técnica e menor agressão biológica possível. Nesse contexto, adesivos auto condicionantes, cimentos auto-adesivos e o selamento imediato da dentina são exemplos de materiais e técnica que estão sendo atualmente difundidos. O objetivo deste trabalho foi avaliar a influência de diferentes tratamentos de superfície para a dentina selada, com adesivo auto condicionante, na resistência de união com cimento resinoso auto-adesivo. As porções coronárias de 90 dentes bovinos, incluídas em cilindros de resina epóxi, foram desgastadas superficialmente até a exposição da dentina. A amostra foi subdividida em seis grupos aleatoriamente. No grupo C (controle) a dentina foi mantida “fresca” enquanto que nos outros cinco grupos foi realizado o selamento imediato da dentina com Clearfil SE Bond (Kuraray). Após armazenamento por 24 horas, receberam diferentes tratamentos da superfície selada: Grupo P (profilaxia com pedra pomes); Grupo PA (profilaxia seguido da aplicação do ácido fosfórico); Grupo PAS (profilaxia, ácido fosfórico e silano); Grupo PASC (profilaxia, ácido fosfórico, silano e adesivo do Clearfil SE Bond) e grupo PAU [profilaxia, ácido fosfórico e Single Bond Universal (3M ESPE)]. Após a realização desses protocolos, foram unidos, em todos os seis grupos, cilindros do cimento auto-adesivo U200 (3M ESPE), formando uma média de 15 unidades amostrais por grupo, sendo assim submetidos ao teste de resistência de união ao microcisalhamento (RUM) à 0,5mm/min para dois tempos de armazenamento: 24 horas (T1) e 3 meses (T2). De acordo com o teste Kruskal-Wallis, para o tempo de 24 horas de armazenamento, houve diferença significante entre os valores de RUM (p=0,0018) para os diferentes protocolos com o grupo PASC apresentando valores significativamente maiores que os demais grupos. Já em relação ao tempo de 3 meses de armazenamento, não houve diferença significante (p=0,223) entre os grupos. É possível concluir que o selamento imediato da dentina produziu valores de resistência de união semelhantes ao grupo controle (sem selamento imediato), recomendado pelo fabricante, exceto para o grupo que associou profilaxia, ácido fosfórico, silano e Clearfil SE Bond que foi significativamente superior nos testes com 24 horas, porém não havendo alterações significativas com 3 meses de armazenamento.
132

Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-out

Rosalyn Chidiak Tawil 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
133

Comparação das técnicas de ativação convencional e cimentação para a união do intermediário ao implante friccional: análise da adaptação marginal e resistência à tração / Comparison of conventional activation and cementation union techniques of the implant-abutment frictional: marginal adaptation analysis and tensile strength

Ramos, Fabiola Nascimento 06 March 2017 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T18:49:45Z No. of bitstreams: 2 Fabíola Nascimento Ramos.pdf: 751579 bytes, checksum: ac3c7ece94f7647842bf2be1f57c97bd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T18:49:45Z (GMT). No. of bitstreams: 2 Fabíola Nascimento Ramos.pdf: 751579 bytes, checksum: ac3c7ece94f7647842bf2be1f57c97bd (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-06 / Loosening implant connections is related to the gaps of the implant-abutment (IA) connections. The objective of this study was to analyze the IA connection frictional as well as the union force of this connection when activation is increased cementation. An in vitro laboratory experiment was performed by one operator, two groups of IA mounts were evaluated means by obtaining images with a stereoscopic loupe. Nine implants were divided into two groups: Group I (GI), in which received conventionally activated attachment ball (Kopp®) prostheses and Group II (G II), in wich dual resin cement (Variolink II®) was added prior to the activation of the abutment. For the analysis of gaps and tensile strength test, Shapiro-Wilk test and F test were used, followed by t test (p <0.05).There was difference between the groups in relation to the gaps; even though the dimensional increase of the gaps, the resist the traction was superior. The cementation suggested to have influenced the increase of the union strengh between the implant-abutment connection, even with the increase of the gaps. / O mecanismo de retenção do intermediário protético ao implante influencia no sucesso clínico da restauração, do ponto de vista biomecânico e histofisiológico dos tecidos perrimplantares. O objetivo deste estudo foi analisar a linha de união entre o intermediário protético e o implante friccional, bem como a força de união desta conexão quando realizada a sua ativação com o bate-conexão-prótese (BCP) e quando a ativação é acrescida de cimentação. Realizou-se um experimento laboratorial, in vitro, onde dois grupos de conjuntos implante/intermediário(I/I), foram avaliados por meio de imagens obtidas com uma lupa estereoscópica. Um grupo de implantes (Grupo I) recebeu intermediários protéticos do tipo attachment bola (Kopp®), ativados convencionalmente. No outro grupo (Grupo II), adicionou-se uma porção de cimento resinoso dual (Variolink II®) previamente à ativação do intermediário.Para a análise estatística dos dados obtidos a partir da leitura dos gaps e do teste de resistência à tração, foram utilizados o teste Shapiro-Wilk e o teste F, seguido pelo teste t (p <0,05). Houve diferença entre os grupos em relação aos gaps; mesmo com o aumento dimensional dos gaps, a resistência à tração foi superior. A cimentação sugeriu ter influenciado o aumento da força de união entre a conexão implante-intermediário.
134

Influencia da cor de cimentos resinosos ativados por diferentes fontes de luz na dureza knoop / Influence of shade of dual-cured resin-based cement in hardness knoop activated for different sources of light

Reges, Rogerio Vieira 29 June 2005 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T13:43:16Z (GMT). No. of bitstreams: 1 Reges_RogerioVieira_D.pdf: 465516 bytes, checksum: 5fc0375c76e29f88888b24dc2e9af545 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a influência de duas fontes de luz sobre a dureza Knoop dos cimentos resinosos Variolink II, nas cores XL transparente ¿ (A1), A3, A2 e Opaco e Enforce B1, A2 e Branco Opaco, nos período imediato e 24 horas após a polimerização. Corpos-de-prova com 5mm de diâmetro por 1mm de espessura dos cimentos resinosos Variolink II (Ivoclar-Vivadent) e Enforce (Denstisply) foram preparados num molde de teflon, cobertos com uma tira de poliéster e disco de cerâmica feldspática Duceram na espessura de 2,0 mm e fotoativados por 40 segundos com aparelho XL 2500 (3M), com 615 mW/cm2 e 40 segundos com o aparelho LED ¿ Ultrablue Is (D.M.C.) com 610 mW/cm2 . A dureza Knoop foi efetuada no aparelho HMV-2, com carga de 50 gramas por 15 segundos, imediatamente e após armazenagem por 24 horas a 37o C. Doze penetrações foram feitas em cada corpo-de-prova para o cimento resinoso Enforce, sendo que cinco corpos-de-prova foram confeccionados para cada cor do cimento e cinco para o grupo controle (sem cerâmica) em cada tempo de armazenagem, totalizando 60 corpos-de-prova. Para o cimento Variolink II, quatro penetrações foram feitas em cada corpo-de-prova, sendo que cinco corpos-de-prova foram confeccionados para cada cor do cimento em cada condição experimental, totalizando 80 corpos-de-prova. Os dados foram submetidos à análise de variância e ao teste de Tukey (5%) e mostraram que o cimento resinoso Variolink II opaco apresentou o menor valor de dureza Knoop em relação as outras cores do cimento, para as duas fontes de luz e dois períodos de ativação (mediato e 24 horas). O aparelho fotoativador de lâmpada halógena apresentou valores de dureza Knoop estatisticamente superior em relação ao aparelho LED para as cores do cimento A2, A3 e opaco para a condição mediato e XL, A2 e A3 após 24 horas. Quando os dois métodos de fotoativação foram comparados para a mesma cor do cimento, os aparelhos fotoativadores com lâmpada halógena e LED (24 horas) apresentaram valores de dureza Knoop estatisticamente superiores aos valores fotoativados na condição mediato. A regressão linear positiva da dureza Knoop foi estabelecida em função da profundidade de fotoativação da amostra do cimento resinoso (Enforce) pela fotoativação direta e indireta pela interposição da cerâmica. O cimento resinoso Enforce na cor opaca mostrou valores de dureza Knoop estatisticamente inferior às outras cores do cimento. A dureza Knoop mediata mostrou valores de dureza Knoop na região de topo (100 µm) estatisticamente superior em relação a dureza na região de fundo (700 µm) / Abstract: The aim of this study was to evaluate the influence of two light sources in Knoop hardness values of resin cement Variolink II in the shade XL transparent (A1), A3, A2, and Opaque and Enforce B1, A2 and Opaque White, in the immediate time and 24 hours after polymerization. The specimens with 5.0 mm in diameter and 1.0 mm in thickness of resin cements Variolink II (Ivoclar-Vivadent) and Enforce (Dentisply) were made in the Teflon mould, covered with a Mylar strip and fledspatic ceramic Duceram Plus (DeguDent) disc 2.0 mm thick and photoactivated for 40 seconds with halogen light unit XL 2500 (3M), with intensity of 615 mW/cm2 and 40 seconds with LED ¿Ultrablue Is (D.M.C.) with power density of 610 mW/cm2. Knoop hardness was measured using HMV-2 (Shimadzu), with a 50g load for 15 seconds, immediately stored at 37o C for 24 hours. Twelve indentations were made in each specimen for the resin cement (Enforce). Five specimens were made for each color and five specimens for the control group (without ceramic) in each stored time, totaling sixty specimens. For the resin cement Variolink II, four indentations were made in each specimen, and five specimens were made for each one in each stored time, totaling eighty specimens. The data were submitted to variance analysis and Tukey¿s test (5%) and showed that the opaque shade of the resin cement had lower Knoop hardness value in relation to the other shades for both light sources and both activation periods (mediate and 24 hours). The halogen units showed Knoop hardness values higher than LED¿s for A2, A3 and opaque for mediate and XL, A2 and A3 after 24 hours. When the photoactivation methods were compared for the same shade halogen and LED (24 hours) showed higher Knoop hardness values than mediate photoactivation. Knoop hardness positive linear regression is a function of depth of specimen of resin cement direct and indirectly photoactivated. Opaque shade showed KHN statistically inferior to the others resin cement groups. Mediate KHN reading showed that Knoop hardness near top (100 µm) is statistically different from bottom surface (700 µm) / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
135

Influencia dos modos de ativação no grau de conversão, resitencia e morfologia da interface de união de sistemas de cimentação e adesivos / Effect of different activation modes on the degree of conversion, tensile bond strength and interfacial morphology of dual-cured cementing systems used in indirect composite restorations

Arrais, Cesar Augusto Galvão 14 December 2006 (has links)
Orientador: Marcelo Giannini / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ondontologia de Piracicaba / Made available in DSpace on 2018-08-08T01:52:29Z (GMT). No. of bitstreams: 1 Arrais_CesarAugustoGalvao_D.pdf: 8768801 bytes, checksum: bf5f97c936134b9476bb797b23d446d6 (MD5) Previous issue date: 2006 / Resumo: A não fotoativação do sistema adesivo previamente à aplicação do cimento resinoso tem sido proposta quando sistemas de cimentação de dupla ativação (SCDA - sistemas adesivos de dupla ativação / cimentos resinosos de dupla ativação) são utilizados. Entretanto, existe uma carência de relatos científicos a respeito da efetividade dos SCDA. Os objetivos deste estudo foram: 1- avaliar a resistência de união (RU) e a morfologia da interface de união de restaurações indiretas de compósito através da utilização da microscopia confocal laser quando os sistemas adesivos de dupla ativação foram ou não fotoativados previamente à aplicação dos cimentos resinosos; 2- analisar o grau de conversão (GC), através da Espectroscopia Infravermelha Transformada de Fourier (FTIR), e a RU de SCDAs quando a fotoativação não foi realizada ou atenuada pela presença da restauração indireta; 3- avaliar o GC e resistência coesiva de sistemas de união quando utilizados diferentes unidades de fotoativação (LEDs e de luz halógena). A RU e resistência coesiva foram avaliadas através do ensaio de microtração. Para a análise em microscopia confocal laser, diferentes corantes foram incorporados nos SCDAs previamente à sua aplicação. Para a análise do GC, os SCDAs foram aplicados na superfície do diamante da unidade de reflectância total atenuada acoplada ao espectrômetro infravermelho. O GC dos sistemas de união não relacionados aos SCDAs foi obtido utilizando-se filmes de resina adesiva. Os resultados demonstraram que a não fotoativação do sistema adesivo de dupla ativação previamente à cimentação não afetou a RU, e que os valores foram até superiores para um SCDA de 4ª geração quando o agente de união não foi fotoativado. A análise em microscopia confocal laser exibiu variação nas características morfológicas da interface de união, variando de acordo com o SCDA utilizado e com o modo de ativação de ambos componentes (sistema adesivo e cimento resinoso). Para alguns SCDAs, o GC foi reduzido pela presença do disco de compósito posicionado entre o SCDA e a ponta da unidade fotoativadora. A não fotoativação dos SCDAs resultou em GC inferiores aos obtidos com exposição direta da luz. A não fotoativação da maioria dos SCDAs também resultou em valores inferiores de RU, exceto quando um sistema de 4ª geração foi utilizado. A utilização de LED resultou em GC inferior ao obtido quando a luz halógena foi utilizada mas não afetou a resistência coesiva dos sistemas adesivos avaliados. Pode-se concluir que a não fotoativação dos sistemas adesivos é uma alternativa aceitável durante a cimentação de restaurações indiretas, porém os SCDAs necessitam de luz fotoativadora para garantir adequada RU. A utilização de LEDs pode comprometer o GC dos sistemas adesivos / Abstract: The lack of light-activation of dual-cured bonding agents before the resin cement application has been an alternative technique of cementing indirect restorations when dual-cured cementing systems are used (DCS ¿ dual-cured bonding agents / dual-cured resin cements). However, few reports exist regarding the effectiveness of DCS when dual-cured bonding agents are left in the uncured state before the seating of the indirect restoration. Therefore, the aims of this study were: 1- to evaluate the microtensile bond strength (MTBS) and micromorphology of the adhesive interface of indirect restorations by confocal laser microscopy (CLSM) when the dual-cured bonding agents were left in the uncured state; 2- to analyze the degree of conversion (DC) by Fourier Transformed Infrared Spectroscopy and the bond strength of indirect restorations when DCSs were applied to the tooth and light activated or allowed to self-cure; 3- to evaluate the DC and ultimate tensile strength (UTS) of bonding agents light-activated with light curing units (LEDs and halogen light). The MTBS and UTS were analyzed using microtensile bond strength test. Different dyes were incorporated to the DCSs before they were applied to teeth for the CSLM analysis. For the DC analysis, the DSCs were applied to the diamond surface of attenuated total reflectance unit of the infrared device. The DC of the bonding agents related to the study evaluating the effectiveness of light-curing units was obtained from thin resin adhesive films. The results demonstrated that the MTBS was not affected, and the values were even higher for one 4th generation DCS, when the dual-bonding agents were left in the uncured state before the resin cement application. The CLSM analysis exhibited some variation in the micromorphological features, which depended on the DCSs and on the curing modes of bonding agents and resin cements. Some DCSs showed lower DC when pre-cured resin composite discs were used. The self-cured groups exhibited lower MTBS than the light-activated ones, except for one 4th generation DCS. The LED promoted lower DC in all bonding agents than did the halogen light. No difference in UTS was observed when LED was used. It was concluded that leaving the dual-cured bonding agent in the uncured state before seating the indirect restoration may be a reliable technique to ensure adequate MTBS, but most DCSs should be light-activated after seating the indirect restoration to provide optimal bond strength. Some LEDs can compromise the DC of adhesive systems / Doutorado / Dentística / Doutor em Clínica Odontológica
136

Resistência de união de um cimento resinoso a diferentes superfícies de alumina densamente sinterizada / Shear bond strenght of a resin cement to different surfaces of densely sintered alumina

Valdivia, Juan Rommel Medina 20 June 2007 (has links)
O propósito deste estudo foi avaliar a resistência adesiva ao cisalhamento de um cimento resinoso à alumina densamente sinterizada testando o tratamento superficial feito pelo fabricante. O cimento utilizado foi o Multilink (Ivoclar Vivadent) e a alumina foi a Procera®Alumina (Nobel Biocare) constituída por 99,9 % de óxido de alumínio densamente sinterizado. Trinta e dois cilindros de alumina foram confeccionados pela Nobel Biocare, onde um dos extremos deste cilindro recebeu o tratamento superficial e o outro não. Para a aplicação do cimento resinoso sobre os cilindros de alumina, utilizou-se uma matriz de Teflon com um orifício central de 3,5mm de diâmetro por 3,0mm de profundidade. Foram determinados 4 grupos experimentais: Grupo 1 superfície sem tratamento; Grupo 2 superfície sem tratamento e com aplicação de adesivo; Grupo 3 - superfície com o tratamento realizado pelo fabricante; Grupo 4 superfície com tratamento realizado pelo fabricante e com adesivo. Após a aplicação do cimento nos 4 grupos, os espécimes foram armazenados em água deionizada a 37ºC durante 24h, sendo, em seguida, montados em uma máquina universal de ensaios para realização dos testes de resistência ao cisalhamento. Os resultados foram submetidos à análise de variância a dois critérios e ao teste de Tukey para comparação entre os grupos. A superfície tratada (grupo 3) apresentou valores significativamente maiores que todos os outros grupos. A presença do adesivo diminuiu a resistência adesiva quando aplicado na superfície tratada, mas não deu diferença significante quando aplicado na superfície sem tratamento. / The aim of this study was to investigate the shear bond strength between a resin cement and densely sintered alumina treated by the fabricant. The resin cement used was the Multilink (Ivoclar Vivadent) and the alumina the Procera®Alumina (Nobel Biocare) made with 99,9% of densely sintered aluminum oxide. Thirty two alumina cylinders were made by Nobel Biocare, and in one of the extremes was applied a own`s fabricant surface treatment. For the application of the cement, a Teflon matrix with a central hole (diameter of 3,5 mm and a height of 3,0 mm) was used. Four groups were created: Group 1 surface without treatment; Group 2 - surface without treatment and with adhesive; Group 3 surface with the own`s fabricant treatment; Group 4 - surface with the own`s fabricant treatment with adhesive. After the cement application, the specimens were stored in water at 37º C for 24 hours. Then the samples were placed in a universal testing machine for making the shear strength test. Statistical analysis was performed with two-way analysis of variance (ANOVA), and paired comparisons between groups were done with Tukey`s multiple comparison. Higher significant values were detected for Group 3 when compared with all the other groups. The adhesive decreased the shear bond strength when laid on the treated surface, and there were no difference when laid on the untreated surface.
137

Resistência à fratura de diferentes núcleos de preenchimento com compósitos bulk fill em dentes com extensa destruição coronária /

Oliveira, Carlos Rangel de Moura January 2019 (has links)
Orientador: José Maurício dos Santos Nunes Reis / Resumo: Este estudo objetivou avaliar a resistência máxima e o padrão de fratura de diferentestécnicas para núcleo preenchimento associados a pinos de fibra de vidro em incisivoslaterais inferiores bovinos com extensa destruição coronária. Quarenta dentes forampreparados endodonticamente, divididos aleatoriamente em 4 grupos experimentais(n=10) e um pino de fibra de vidro (Whitepost DC0,5) foi cimentado com LuxaCore Zpara todos os grupos. A confecção dos núcleos de preenchimento foi realizada, apósobtenção de férula cervical de 1,0 mm, com: FOBF-Filtek One Bulk Fill; FZ350- FiltekZ350 XT; FBFF-Filtek Bulk Fill Flow; e LCZ-LuxaCore Z. Coroas totais de zircônia (YTZP) produzidas em CAD/CAM foram cimentadas com RelyX U200. Apósarmazenamento em água destilada a 37°C por 48 h, os corpos-de-prova foramsubmetidos a ciclos térmicos (10.000 ciclos, 5-55ºC, banhos de 30s) e, posteriormente,ao ensaio mecânico de resistência à fratura por força compressiva aplicada (1,0mm/min) em 135º ao longo eixo do dente em máquina eletromecânica (EMIC DL2000).A força máxima suportada por cada espécime foi registrada em Newton. O modo defratura foi classificado por meio de análise em lupa estereomicroscópica (30X). Osdados de resistência à fratura foram analisados pelo teste não paramétrico de KruskalWallis, seguido pelo post-hoc teste de Dunn. Os dados dos padrões de fratura foramanalisados pelo teste exato de Fisher (α=0,05). Não foram observadas diferençassignificativas (p>0... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the ultimate fracture strength and failure modes of different core techniques associated with intraradicular fiberpost in bovine mandibular lateral incisors with extensive coronary destruction. Forty teeth were prepared endodontically, randomly divided into 4 experimental groups (n=10) and a fiberpost (Whitepost DC0.5) was cemented with LuxaCore Z for all groups. The core was confeccioned, after obtaining a 1.0 mm cervical ferrule, with: FOBF-Filtek One Bulk Fill; FZ350- Filtek Z350 XT; FBFF-Filtek Bulk Fill Flow; and LCZ-LuxaCore Z. Total zirconia crowns (Y-TZP) produced by CAD/CAM were cemented with RelyX U200. After storage in distilled water at 37ºC for 48 h, the specimens were submitted to thermal cycling (10,000 cycles, 5- 55ºC, 30 s dwell time) and, afterwards, to the mechanical test of compressive strength fracture (1.0 mm / min) at 135º along the tooth axis in electromechanical machine (EMIC DL2000). The ultimate load supported by each specimen was recorded in Newton. The fracture mode was classified by means of stereomicroscopic loupe analysis (30X). The fracture strength data were analyzed by the non-parametric Kruskal-Wallis test, followed by the post-hoc Dunn test. The data of the fracture modes were analyzed by Fisher's exact test (α=0.05). No significant differences (p>0.05) were observed among the FOBF, FZ350 and FBFF groups (mean ranks= 20.30, 12.20 and 23.20, respectively). LCZ (mean rank= 26.30) produced similar results to those... (Complete abstract click electronic access below) / Mestre
138

AVALIAÇÃO DA ESTABILIDADE DE COR DE LAMINADOS CERÂMICOS APÓS CIMENTAÇÃO ADESIVA / Evaluation of color stability of ceramic veneers after adhesive cementation

Sakamoto Junior, Antonio Setsuo 22 December 2015 (has links)
Made available in DSpace on 2017-07-24T19:21:58Z (GMT). No. of bitstreams: 1 Antonio Setsuo Sakamoto Junior.pdf: 2373735 bytes, checksum: b35b9e1a804cb1e6e80c6137dada9016 (MD5) Previous issue date: 2015-12-22 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Thin ceramic laminates have been widely requested by patients because it’s a reliable conservative aesthetic procedure, stable and presents adequate longevity. It is known that the color change of the cement below these thin restorations may result inappropriate final color. Thus, the purpose of this in vitro study was to evaluate the color agreement between pressable lithium disilicate ceramics with tryin pastes and corresponding resin cements, determination of the degree of conversion of resin cements using FT-Raman spectroscopic and color stability after artificial accelerated aging (AAA) for 300 hours. Eighty-four ceramic discs (0.3 mm, 0.5 mm, 1.0 mm thick) were prepared (IPS e.maxPress HT A2 – Ivoclar Vivadent) to simulate veneers. Evaluation the baseline color was done in the CIE-L*a*b* color space with reflectance spectrophotometer (control group). The try-in pastes were applied into the interlayer of the ceramic (simulation of selection color procedure) above silicon transparent matrix (0.1 mm thick) and the color complex were measured using a spectrophotometer (n=7), with no substrate. The same ceramic discs were used for cementation procedure with Variolink II (only base),after storage in distilled water, protected from light, at 37ºC for 24 hours, the specimens were mensured the color and submitted to FT-Raman spectroscopy to determinate the degree of conversion (DC). After that, the specimens were AAA for 300 hours and measured by spectrophotometer to calculate ΔE. Two-way ANOVA was used to analyze the data. Tukey’s post hoc for multiple comparisons and Spearman correlation test were performed (α = 0.05). There was no agreement between the try-in with resin cements, L* and b* values increased, increasing the value/opacity,yellowish of the complex. All groups exhibited values of ΔE>3.3, except resin color A3 group (1.0 mm ceramic thickness). Ceramic thicknesses (0.3 mm and 0.5 mm) did not affect the DC compared to the control (p> 0.05). Thus, DC was influenced by the color of cement, where the over saturated color showed higher conversion rate, DC decreased when ceramic disc thickness increased. No correlation between DC and ΔE was observed. / A modalidade indireta de restauração denominada laminado cerâmico, vem sendo vastamente solicitada pelos pacientes, por se tratar de um procedimento confiável, estável, conservador, estético e apresenta longevidade aceitável. Sabe-se que a alteração de cor do cimento localizado abaixo destas restaurações delgadas pode influenciar negativamente no aspecto estético final. Desta forma, o propósito do presente estudo in vitro foi avaliar a concordância da coloração da pasta de prova e seu respectivo cimento resinoso, verificar o grau de conversão deste pelo método Micro-Raman e sua estabilidade de cor após envelhecimento artificial acelerado (EAA) por 300 horas. Foram confeccionados 84 discos cerâmicos com sistema IPS e.maxPress HT (Ivoclar Vivadent) na cor A2 com 3 espessuras (0.3 mm, 0.5 mm, 1.0 mm) cuja coloração foi mensurada com espectrofotometria de refletância (grupo controle). Em seguida, foi realizada a simulação da seleção da cor do cimento Variolink II (try in Transparente, Opaco, A3) e mensurada a cor do conjunto nas coordenadas CIEL* a*b*. Depois foi realizada a cimentação adesiva (mesmos discos cerâmicos utilizados com try in) com três cores de cimentos resinosos (Base: Transparente, Opaco, A3), sobre uma matriz de silicone transparente com cavidade de espessura de 0,1 mm (n=7), sem qualquer substrato. Após armazenamento com água destilada, protegido da luz, em estufa a 37ºC por 24h, os corpos de prova (cp) foram submetidos novamente ao teste de espectrofotometria e ao teste grau de conversão (GC) pelo método FT-Raman. Em seguida, foram submetidos ao EAA por 300 horas e mensurada a coloração para verificar se houve alteração (ΔE). Os dados coletados foram submetidos à ANOVA 2 fatores, seguido pelo pós-teste de Tukey e pelo teste de correlação de Spearman (α=0,05). Não houve concordância entre o try in e respectivo cimento, os valores de L* e b* aumentaram, tornando mais luminosa/opaca e amarelada. Todos grupos apresentaram valores superiores de ΔE=3,3, exceto o grupo do cimento cor A3 (cerâmica espessura de 1,0 mm) e as espessuras cerâmicas de 0,3 e 0,5 mm não influenciaram o GC, onde apresentaram valores sem diferença significativa (p>0,05) comparada ao grupo controle. Assim, o GC foi influenciado pela cor do cimento, onde o mais saturado apresentou maior taxa de conversão, ao passo que o valor de GC diminuiu quando a espessura do disco cerâmico interposto aumentou. Não houve relação entre o GC e ΔE.
139

Análise não-linear do mecanismo de cimentação de pinos intra-radiculares utilizando o método dos elementos finitos / NO-LINEAR ANALYSIS OF CEMENTATION MECHANISM IN ROOT POSTS USING THE FINITES ELEMENTS METHOD

Franco, Ana Paula Gebert de Oliveira 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:08Z (GMT). No. of bitstreams: 1 Ana Paula Gebert.pdf: 9068136 bytes, checksum: 8f06dbf649af9345afc6e09a57f71fb6 (MD5) Previous issue date: 2008-02-26 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim is to analyze a non-linear mechanism of the cementation of root posts considering the existence of gaps in cement-dentin and cement-post interfaces analyzing the correlation of mechanical test and computational model. Were selected 15 mandibular pre-molars, to receive root posts Exacto (Angelus®/Londrina - Brazil) fixed with chemical resin cement Cement-Post (Angelus®/Londrina - Brazil). The teeth were termocycled, radiographed and cuted themselves getting cervical, middle and apical discs of roots. These discs were treated and molded with addition of silicone and epoxy resin replics was obtained before and after the compression test (220 N-0, 2 mm / min). The replics were analyzed in MEV to observe the formation of gaps at the interfaces on the upper surfaces of the specimens, which were measured in the Image Tool program. For statistical analysis of the comparison between the mensures of gaps (μm) in the interface was used in the Wilcoxon test which showed that there were statistical differences between groups (p <0.0001). In the comparison between the mensures of gaps in the same interface of the cervical, middle and apical discs before and after the compression test, there was no statistically significant difference (p = 0.4304) and (p = 0.7766), respectively. In cement-post interface there was no gaps in most specimens. The dentin discs were photographed and their images obtained from three-dimensional models simulating the compression test using the Finite Elements Method, considering linear-elastic material with values of module of elasticity and Poisson's coefficient, and obtained in the mechanical test of the traction, compression and bending resistance in the post and/or the cement. There was the Poisson's effect and a low stress concentration in dentin-cement and cement-post interfaces promoted by the force application, geometry and materials properties. In assessing the match of the mechanical test with the computational model, met a difference because of the consideration of perfect adhesion in computational model of the cervical and middle discs, which does not occur clinically, as there was formation of gaps in some root regions of the dentin discs. The apical discs were modeled like non-linear and it was considered an area of contact between the faces. / O objetivo é analisar de forma não-linear o mecanismo de cimentação de pinos intra-radiculares considerando a existência das fendas nas interfaces dentina-cimento-pino analisando a correspondência do ensaio mecânico e modelo computacional. Foram selecionados 15 pré-molares inferiores, para receber pinos intra-radiculares Exacto (Angelus®/Londrina - Brasil) fixados com cimento resinoso autopolimerizável Cement-Post (Angelus®/Londrina - Brasil). Os dentes foram termociclados, radiografados e cortados obtendo-se discos cervicais, médios e apicais das raízes. Esses discos foram tratados e moldados com silicone de adição e obtidas réplicas de resina epoxi antes e após o ensaio de compressão (220 N-0,2 mm/min). As réplicas foram analisadas em MEV para observar a formação de fendas nas interfaces nas faces superiores dos espécimes, as quais foram medidas no programa Image Tool. Para análise estatística da comparação entre as medidas de fendas (μm) na interface foi utilizado o teste Wilcoxon que demonstrou que houve diferenças estatísticas entre os grupos (p < 0,0001). Na comparação entre as medidas de fendas da mesma interface dos discos cervical, médio e apical antes e depois do ensaio de compressão, não houve diferenças significantes estatisticamente (p = 0,4304) e (p = 0,7766), respectivamente. Na interface cimento-pino observou-se ausência de fendas na maior parte dos espécimes. Os discos de dentina foram fotografados e a partir de suas imagens obtidos modelos tri-dimensionais analisados simulando-se o ensaio de compressão por meio do Método dos Elementos Finitos, considerando material elástico-linear com valores de módulo de elasticidade e Coeficiente de Poisson e, obtidos de ensaios mecânicos de resistência à tração, compressão e flexão realizados no pino e/ou no cimento. Observou-se o efeito Poisson e que houve uma concentração leve de tensões nas interfaces dentina-cimento e cimento-pino promovidas pela forma de aplicação da força, geometria e propriedades dos materiais. Na avaliação da correspondência do ensaio mecânico com o modelo computacional, encontrou-se uma diferença devido à consideração de adesão perfeita no modelo computacional dos discos cervicais e médios, o que não ocorre clinicamente, visto que houve formação de fendas em algumas regiões radiculares dos discos de dentina. Os discos apicais foram modelados de maneira não-linear, considerando-se uma superfície de contato entre as faces.
140

Influência do sistema de cimentação e do modo de ativação na resistência ao push-out de pinos de fibra de vidro / Influence of cementation system and activation mode on push-out bond strength of glass fiber posts

Reinaldo de Souza Ferreira 04 December 2009 (has links)
O objetivo deste estudo foi avaliar a influência do tipo de sistema de cimentação (condicionamento ácido total ou autoadesivo), do modo de ativação (autoativado ou dual), do terço do conduto radicular (cervical, médio ou apical) e da espessura do filme de cimento sobre a resistência de união de pinos de fibra de vidro cimentados em dentes humanos. Quarenta raízes foram incluídas em resina epóxi, submetidas a tratamento endodôntico e obturadas com guta percha e cimento endodôntico sem eugenol. Decorridos sete dias, os condutos foram preparados a uma profundidade de 10mm com brocas padronizadas do sistema dos pinos de fibra (WhitePost DC #2) e aleatoriamente divididos em 4 grupos, conforme o sistema de cimentação e o modo de ativação: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (condicionamento ácido total), ativação dual, (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, autoativado, (G3) RelyX U100 (autoadesivo), dual e (G4) RelyX U100, autoativado. Após uma semana, cada raiz foi seccionada em máquina de corte, originando 6 fatias de 1 mm de espessura (n=60). Antes do ensaio de push-out cada fatia foi fotografada em ambas as faces, para determinação do raio dos pinos e da espessura do filme de cimento. Após o ensaio mecânico, novas imagens foram capturadas para determinação do modo de falha. Para automatizar a determinação da espessura de cimento, foi desenvolvida uma macro no software KS 400. Os dados foram estatisticamente analisados com ANOVA 3 fatores (resistência de união) e teste de Kruskall-Wallis (espessura do cimento). Comparações múltiplas foram realizadas com o teste Student-Newman-Keuls. Análise de regressão, modelo linear, foi empregada para verificar a correlação entre espessura do cimento e resistência de união. Todos os testes foram aplicados com &#945; = 0,05. O fator cimento exerceu influência significativa para a resistência de união (p = 0,0402): o RelyX U100 apresentou a maior média. A ativação dual elevou os valores de resistência de união em comparação ao modo quimicamente ativado (p < 0,0001). Houve diferenças significantes entre os grupos, sendo G1 (22,4 4,0 MPa) > G3 (20,4 3,6 MPa) > G4 (17,8 5,2 MPa) > G2 (13,5 4,3 MPa). O terço do conduto não exerceu influência significativa sobre a resistência adesiva (p = 0,4749). As espessuras dos filmes de cimento foram estatisticamente diferentes nos diferentes terços: cervical (102 45 m) > médio (75 29 m) > apical (52 28m). Não foi observada forte correlação entre os valores de espessura e os de resistência ao push-out (r = - 0,2016, p = 0,0033). O tipo de falha predominante foi a mista, exceto para o G2, que apresentou 74% das falhas na interface cimento-pino. Dessa forma, o cimento autoadesivo apresentou melhor desempenho que o convencional, e ambos os sistemas duais, sobretudo o RelyX ARC, apresentaram dependência da fotoativação para atingirem maiores valores de resistência de união. / The aim of this study was to evaluate the influence of adhesive cementation system approach (total-etch or self-adhesive), activation mode (self-cure or dual-cure), canal third (cervical, middle or apical) and cement thickness on push-out bond strength of glass fiber post bonded on human roots. Forty roots were embebed in epoxy resin and endodontically treated (filled with guta percha and non-eugenol endodontic sealer). Following 7 days, the post spaces were prepared with low-speed post drills provided by the manufacturer (WhitePost DC #2, FGM) at a depth of 10 mm and the roots were randomly divided in 4 groups, according to cementation system and activations mode: (G1) RelyX ARC/Adper Scotchbond Multi-Purpose Plus (total-etch), dual-cure (G2) RelyX ARC/Adper Scotchbond Multi-Purpose Plus, self-cure, (G3) RelyX U100 (self-adhesive), dual-cure and (G4) RelyX U100, self-cure. After 7 days, each root was sectioned with water-cooled diamond blade, generating six 1-mm thickness slices (n=60). Before push-out bond strength test, digital images of both sides of the slices were captured with digital camera, in order to measure the post radius and the cement thickness. After mechanical test, new images were captured to evaluate the failure mode. A macro was developed in KS 400 software to speed and standardize the evaluation of cement thickness. Results were analyzed using three-way ANOVA (push-out) and Kruskall-Wallis test (cement thickness). Post-hoc multiple comparisons were performed using the Student-Newman-Keuls test. The correlation between resin cement thickness and bond strength was evaluated with regression analysis, linear model. All tests were performed with significance level set at 0.05. Push-out bond strength was significantly influenced by cement type (p= 0.0402): the RelyX U100 cement presented higher mean value. The dual-activated mode increased the bond strength in comparison to self-activated mode (p < 0.0001). Statically differences were observed between groups: G1 (22.4 4.0 MPa) > G3 (20.4 3.6 MPa) > G4 (17.8 5.2 MPa) > G2 (13.5 4.3 MPa). Bond strength was not affected by post space depth (p = 0,4749). The resin cement thicknesses were significantly different in root thirds: cervical (102 45 m) > middle (75 29 m) > apical (52 28m). No strong correlation between cement thickness and push-out bond strength was observed (r = - 0.2016, p = 0.0033). The main failure mode was mixed, except for G2 (74% adhesive failures at post-cement interface). It was concluded tha the self-adhesive cement showed a better performance than the conventional one, and both dual resin systems, specially the RelyX ARC, presented photo-activation dependence to attain greater adhesive bond strength.

Page generated in 0.1238 seconds