• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 322
  • 46
  • 46
  • 46
  • 45
  • 35
  • 7
  • 7
  • 7
  • 4
  • 4
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 327
  • 327
  • 143
  • 131
  • 109
  • 79
  • 58
  • 57
  • 53
  • 40
  • 40
  • 34
  • 30
  • 28
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Resistência de união, índice de remanescente adesivo e avaliação da presença de esmalte sobre a base de braquetes após descolagem : estudo in vitro /

Tonetto, Mateus Rodrigues. January 2014 (has links)
Orientador: Marcelo Ferrarezi de Andrade / Banca: Karina eiras Dela Coleta Pizzol / Banca: Flavia Magnani Bevilacqua / Banca: Andréa Abi Rached Dantas / Banca: Edson Alves de Campos / Resumo: Este estudo in vitro avaliou a resistência de união e índice de remanescente adesivo (IRA) de um braquete modificado colado com cimento resinoso auto-adesivo, e verificou a presença de substrato de esmalte na base do braquete após a descolagem. Foram selecionados noventa dentes bovinos e distribuidos aleatoriamente (n=15) de acordo com os grupos: G1 - Braquetes metálicos colados com Transbond™ XT; G2 - Braquetes metálicos do sistema APC colados sem procedimento adesivo adicional; G3 - Braquetes metálicos do sistema APC colados com sistema adesivo auto-condicionante; G4 - Braquetes metálicos colados com RelyX U200; G5 - Braquetes modificados (alteração na base do braquete Victory™) colados com Transbond™ XT; G6 - Braquetes modificados colados com RelyX U200. Foi realizado ensaio de resistência ao cisalhamento dos braquetes e após a remoção dos mesmos, o IRA foi observado em lupa estereoscópica (30x) (Carl Zeiss, Brasil) e as bases dos braquetes foram verificadas quanto a presença de resíduos de esmalte dental (Ca) por meio de EDS. Os resultados mostraram que o maior valor médio de resistência ao cisalhamento foi encontrado no grupo 1 (14,33 MPa) e o menor valor médio de resistência ao cisalhamento foi no grupo 4 (2,36 MPa). O IRA foi avaliado e os grupos que utilizaram o ácido fosfórico ou primer autocondicionante (grupos 1, 2, 3 e 5) apresentaram adesivo parcialmente e totalmente aderido ao dente. Quanto ao remanescente adesivo na base do braquete, o EDS identificou substratos de esmalte nos grupos 1 e 3 enquanto nos outros grupos verificou-se apenas remanescente adesivo sobre a base do braquete. Os resultados mostraram que os valores médio de resistência ao cisalhamento encontrados nos grupos de base modificada foram suficientes para suportar o tratamento ortodôntico. Após análise por EDS, concluiu-se que os braquetes modificados mostraram-se livres de fragmentos de esmalte, o que sugere a possível... / Abstract:This study evaluated the bond strength of an experimental bracket bonded with selfadhesive resin cement, assessed the presence of enamel substrate on the bracket base after debonding and reviewed the possible methods to remove the remnant of enamel surface. Ninety bovine teeth were selected; the roots were sectioned and embedded in acrylic resin. The teeth were randomly assigned (n=15) according to the groups: G1 - metal brackets (Victory™) bonded with total etch adhesive system (Transbond™ XT), G2 - metal brackets APC (APC Plus System) without additional adhesive procedure; G3 - metal brackets APC (APC Plus system) bonded with selfetching adhesive system; G4 - metal brackets (Victory™) bonded with self-adhesive resin cement (RelyX U100); G5 - experimental brackets (modified on the Victory™ bracket basis) bonded with total etch adhesive system (Transbond™ XT); G6 - experimental brackets (modified on the Victory™ bracket basis) bonded with selfadhesive resin cement (RelyX U100) . Shear strength test of brackets was performed and after removal of the brackets, the adhesive remnant index (ARI) was observed in a stereomicroscope (30x) (Carl Zeiss, Brazil) and the bases of brackets were checked for the presence of enamel residues (Ca) by EDS . The results showed that the highest average value of shear strength was found in group 1 (14.33 MPa) and lower mean shear strength was in group 4 (2.36 MPa). Of the remaining adhesive on the bracket base EDS identified enamel substrates in groups 1 and 3, while the other groups there was only remaining adhesive on the bracket base. Therefore the experimental brackets are possible to be used in the future for orthodontics for showing lower risk of damage to the enamel. / Doutor
132

Resistência de união á dentina do canal radicular de cimentos endodônticos, em função da medicação intracanal com hidróxido de cálcio /

Guiotti, Flávia Angelica. January 2012 (has links)
Orientador: Milton Carlos Kuga / Banca: Gisele Faria / Banca: Arnaldo Sant'Anna junior / Resumo: Este estudo foi dividido em dois capítulos, tendo como objetivo comparar, através do teste de push-out, a resistência de união do cimento MTA Fillapex (Angelus, Londrina, PR, BR), Sealapex (SybronEndo, Orange, CA, USA) e AH Plus (Dentsply De Trey Gmbh , Konstanz, GE) às paredes do canal radicular de dentes humanos extraídos, após o uso prévio de três tipos de medicação intracanal contendo hidróxido de cálcio: Calen (SS White, São Paulo, SP, BR), Pasta HPG (hidróxido de cálcio, paramonoclorofenol canforado e glicerina) e Ca(OH)2 + água (hidróxido de cálcio + água). Foram utilizados 60 dentes unirradiculares, que tiveram suas coroas seccionadas na junção amelocementária. As raízes foram incluídas em resina epóxi e cortadas transversalmente em fatias de 2 mm dos terços cervical, médio e apical das raízes. Em seguida, utilizando uma fresa tronco-cônica acoplada em micromotor, devidamente adaptado em um delineador, os canais foram preparados, padronizados e submetidos à irrigação com o EDTA a 17%. No primeiro estudo (Capítulo 1), os espécimes foram divididos em seis grupos: G1- MTA Fillapex; G2-Sealapex; G3-AH Plus, após o uso prévio das respectivas medicações com hidróxido de cálcio, por 21 dias. Após este período, os espécimes foram irrigados com NaOCl a 2,5% e EDTA a 17%, sendo então preenchidos com um dos cimentos em estudo, mantendo os corpos de prova por 7 dias, a 37˚C e 95% de umidade. Nos grupos 4, 5 e 6 foram utilizados os mesmos cimentos, sem uso da medicação intracanal, respectivamente. No segundo estudo (Capílulo 2), os espécimes foram distribuídos por grupos e os canais radiculares obturados com: G1- MTA Fillapex e G2-Sealapex. Cada grupo foi subdividido em três sub-grupos, em função da associação da medicação intracanal com hidróxido de cálcio previamente empregada: A - sem medicação; B - Ca(OH)2 + água destilada... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study, divided in two chapters, was to evaluate and to compare the push-out bond strength of three root canal sealers to the root canal walls of human extracted teeth: MTA Fillapex (Angelus, Londrina, PR, BR), Sealapex (SybronEndo, Orange, CA, USA) and AH Plus (Dentsply De Trey Gmbh, Konstanz, GE), after the previous use with three calcium hydroxide compositions with intracanal medication: Calen (SS White, São Paulo, SP, BR), HPG paste (Calcium hydroxide, Paramonoclorofenol canforado and Glycerin) and Calcium hydroxide with water paste. Sixty unirradicular teeth were sectioned transversally below the cement-enamel junction. The roots were included in epoxy resin and cut transversally, obtained 2 mm-thick cross-section slices of cervical, middle and apical radicular thirds. In sequence, using a conic drill adjusted in a low electric piece adapted in a pararelometer , the canals were prepared, standardized and submitted to irrigation with EDTA to 17%. In the first study (Chapter 1), the specimens were divided into six groups: G1-MTA Fillapex; G2-Sealapex; G3-OH Plus, after the prior use of calcium hydroxide intracanal medication, by 21 days. After, were irrigated with the 2.5% NaOCl and then filled with one of the materials, stored at 37˚C, for 7 days and 95% of relative humidity. In groups 4, 5 and 6 were used the same cement, without intracanal medication, respectively. In the second study (Chapter 2), the specimens weredivided and the canals obturated with: G1- Fillapex MTA and G2-Sealapex. Each group was subdivided into three sub-groups, depending of the calcium hydroxide intracanal medication composition, previously used: A-without medication; B- distilled water and C- Glycerin/camphorate paramonochlorophenol . After 7 days, the specimens were submitted to the push-out test in mechanical testing machine. The data were analyzed with ANOVA and Tukey test (α = 5%)... (Complete abstract click electronic access below) / Mestre
133

Efeitos do tipo de sistema adesivo e região do dente sobre a resistência adesiva à dentina /

Melo, Renata Marques de. January 2005 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Paulo Sérgio Mutarelli / Banca: Carlos Rocha Gomes Torres / Resumo: Este estudo foi realizado no intuito de avaliar a resistência de união à dentina coronária e do canal radicular com dois sistemas adesivos de condicionamento total (dois e três passos) e um sistema autocondicionante. Os canais de trinta incisivos e caninos humanos superiores foram instrumentados e preparados com brocas. Os pinos usados na cimentação foram réplicas em cimento resinoso dual Duo-link do pino Aestheti Plus #2. Assim, constituíram-se três grupos (n = 10), segundo o sistema adesivo utilizado: condicionamento total três passos (CT3) - AII-Bond 2 + pino em cimento resinoso (pcr)+ Duo-link (DI); condicionamento total 2 passos (CT2) - One-Step Plus + pcr + DI; autocondicionante (AC) - Tyrian/One-Step Plus+ pcr + DI. Apôs a cimentação, foram obtidas oito secções transversais (1,5mm), a partir de 4mm acima da JEC até 4mm aquém do ápice do canal, envolvendo dentina coronária e radicular. As secções foram submetidas ao ensaio de push-out em máquina de ensaio universal EMIC (1 mm.min-1). Os dados de resistêncía adesiva foram analisados com o teste ANOVA de dois fatores de medidas repetidas (α<0,05). Foi observado que o efeito interação foi estatisticamente significante, isto é, o relacionamento entre os adesivos não foi o mesmo para as diferentes regiões. Comparando-se as médias obtidas com os adesivos em cada região (Tukey; α<0,05), observou-se que o CT3 (média± desvio padrão: 5,22 ± 1,70) foi superior ao CT2 (2,60 ± 1,74) e ao AC (1,68 ± 1,85). Para as condições estudadas, obteve-se melhor adesão à dentina com a utilização do sistema adesivo de condicionamento total com três passos, sobretudo na região coronária / Abstract: This study aimed to evaluate lhe bond strengths between two total etching adhesive systems and (two and three steps) anda self-etching system to coronal and root canal dentin. The root canal of thirty human anterior teeth were endodontically instrumented and prepared with specific burs. Aestheti Plus #2 posts were duplicated in dual resin cement (Duo-link) and three groups (n=10) were formed, according to the adhesive sysfem used: 3 steps total etching adhesive system (3TE) - All-Bond 2 + resin cement post (rcp) + Duo-link (DI); 2 steps total etching adhesive system (2TE) - One-Step Plus + rcp + DI; sef-etching system (SE) Tyrian/One-Step Plus + rcp +DI. Following cementation, the teeth were cut transversally in eight sections (1,5mm), from the CEJ to 4mm above the canal apex. The sections were subjected to the push-out test in a universal testing machine (1mm.min-1). The data of bond strength were statistically analyzed with 2-way Anova of repeated measures (α<0.05), which showed that the interaction effect was significant. This meant that the relationship between the adhesives was not the same depending on the tooth region. Regarding the "adhesive factor'' the comparison of means with Tukey test (α<0.05) showed that 3TE (mean ± standard deviation: 5,22 ± 1,70) was statistically superior to 2TE (2,60 ± 1,74) and SE (1,68 ± 1,85). Under the conditions of the present study, the three step total etching system had the highest bond strengths to dentin, especially in the coronal region / Mestre
134

Resistência de união de cimentos resinosos, ao cisalhamento, variando o substrato e o material restaurador /

Ariki, Eurípedes Kaizo. January 2009 (has links)
Orientador: Carlos Augusto Pavanelli / Banca: Eduardo Galera da Silva / Banca: Marco Antonio Meloncini / Resumo: O objetivo deste estudo foi avaliar a resistência de união ao cisalhamento de três diferentes tipos de agentes cimentantes: auto-condicionante (Panavia F / P), convencional (RelyX ARC - R) e auto-adesivo (RelyX U100 - U), usando dois tipos de substratos (esmalte / E e dentina / D) e dois tipos de materiais restauradores (cerâmica - C e resina composta laboratorial - R). Foram utilizados cento e vinte incisivos bovinos incluídos em resina acrílica, de modo que uma parte da face vestibular ficasse exposta. Os dentes foram desgastados até se obter uma área lisa e plana, de aproximadamente de 25 mm2, em metade dos espécimes foi exposto esmalte, na outra metade dentina. Uma fita adesiva com um orifício no centro com 3 mm de diâmetro foi colada sobre estas áreas, delimitando a área a ser usada no teste. Foram confeccionados sessenta cilindros de cerâmica a base de dissilicato de lítio (IPS e.max) e sessenta cilindros de resina composta (SR Adoro) com dimensões de 3mm de diâmetro e 3mm de altura. Os cilindros foram cimentados aos substratos com os três tipos de cimento resinoso, formando doze grupos experimentais: G1(PEC); G2(PER); G3(PDC); G4(PDR); G5(REC), G6(RER); G7(RDC); G8(RDR): G9(UEC); G10(UER); G11(UDC) e G12(UDR). Após um período de uma semana, os corpos-de-prova foram levados à máquina de ensaios universais para a realização do teste de cisalhamento com velocidade de 0,5 mm/min. Os resultados (foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey em nível de 5% de significância. Verificou-se que o maior valor médio obtido foi do G5 (17,46 MPa) diferindo significativamente dos demais grupos, exceto do G1 (14,60 MPa). O G12 (1,03 MPa) apresentou o menor valor de resistência, não apresentando semelhança estatística com os outros grupos. A adesão em esmalte... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of the present study was to evaluate the shear bond strength of three types of luting agents: self-etching (Panavia F, P), conventional (Rely X ARC, R) and self-adhesive (Rely X U100, U), using enamel (E) or dentin (D) as substrates and two types of restorative materials (ceramic, C and laboratorial composite, R). One hundred and twenty-five bovine incisors were embedded in acrylic resin leaving their bucal side exposed. The teeth were ground flat until a 5mm2 area was created. Half of the specimens had enamel exposed and the other half had dentin exposed. A piece of tape with a 3 mm hole was used to delimitate the bonding area. Sixty cylinders of ceramic (IPS E.max Press) and sixty of composite (SR Adoro), 3 mm in diameter and 3 mm in height, were confectioned. The cylinders were luted to the substrates, forming twelve groups: G1 (PEC); G2 (PER); G3 (PDC); G4 (PDR); G5 (REC), G6 (RER); G7 (RDC); G8(RDR): G9 (UEC); G10(UER); G11(UDC) and G12(UDR). After one week, the specimens were subjected to a shear test in a universal testing machine at a crosshead speed of 0,5 mm/min. The results were submitted to both the Anova and Tukey tests (p<0.05) for statistical analysis. It was observed that the mean of G5 (17,46 MPa) was significantly different from the other groups means, except for G1 (14,60 MPa). Statistically G12 (1,03) had the lowest bond strength differing from the other groups. Bondings between was ceramic and enamel determined the highest bond strength for all luting agents. Due to the low bond strength and the failures between cement and substrate, using the self-adhesive cement and laboratorial composite to make bonds is not advisable. / Mestre
135

Avaliação da biocompatibilidade de dois adesivos dentinários pelo estudo das reações teciduais em conjuntivo de ratos /

Gomes, Ana Paula Martins. January 1994 (has links)
Orientador: Jaime Freitas Ribeiro / Banca: Carlos Eduardo Aun / Banca: Maria Amélia Maxímo de Araújo / Resumo: A biocompatibilidade de dois adesivos dentinários (Scotchbond MultiPurpose- 3M e Optibond Multi-Use - Kerr) foi avaliada por meio de implantes em tecido conjuntivo subcutâneo de ratos. Os implantes foram realizados, utilizando-se tubos de polietileno preenchidos com os respectivos adesivos e inseridos em lojas cirúrgicas preparadas no dorso dos animais, os quais foram sacrificados nos periodos de observação de 14, 30, 60 e 84 dias. Os tecidos circunjacentes aos implantes foram removidos, incluídos em parafina e corados com hematoxilina e eosina para análise em microscopia óptica. Os resultados mostraram moderado a discreto infiltrado inflamatório nos períodos iniciais de observação (14 e 30 dias) e reparação da área nos períodos posteriores (60 e 84 dias), com formação de cápsula fibrosa envolvendo todos os implantes. Os resultados obtidos nos permitiram concluir que: a) os dois adesivos dentinários são biologicamente aceitáveis quando colocados em contato com o tecido conjuntivo subcutâneo de ratos; b) houve reação moderada do tecido conjuntivo subcutâneo de ratos aos dois adesivos dentinários no período de observação de 14 dias, a qual persistiu com o adesivo Optibond MultiUse-light cure- (Kerr) aos 30 dias; c) as reações teciduais provocadas pelos dois adesivos nos períodos de observação de 60 e 84 dias foram semelhantes e biologicamente aceitáveis / Abstract: The biocompatibility of two dentin adhesives (Scotchbond MultiPurpose- 3M and Optibond Multi-Use - Kerr) was evaluated in rats subcutaneous connective tissue implants. Polyethylene tubes filled with the adhesives were surgically implanted into the dorsal subcutaneous tissues of rats. The tubes were left implanted for periods of 14, 30, 60 and 84 days, following wich the animais were killed and the implants, together with the surrounding tissue, were excised. The specimens were then fixed in 10 per cent formalin, sectioned serially and stained with hematoxylin and eosin and then, examined by light microscopy. After 14 and 30 days the tubes were surrounded by a mild to moderate inflammatory infiltration. After 60 and 84 days microscopic examination revealed the formation of a connective tissue capsule around each tube. The microscopic examination of the biopsy specimens allowed to conclude that: a) both dentin adhesives are considered biologically acceptable when placed in contact with rats subcutaneous connective tissue; b) in the observation period of 30 days there were moderate tissue reaction to the Optibond Multi-Use -light cure- (Kerr); c) after 60 and 84 days the use of both dentine adhesives did not interfere in the healing of the surrounding connective tissue / Mestre
136

Adesivos multi-uso-avaliação da resistência adesiva a dentina frente a teste de cisalhamento, estereomicroscopia e microscopia eletrônica de varredura /

Gonçalves, Sérgio Eduardo de Paiva. January 1994 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Dan Mihail Fichman / Banca: Rogerio Lacaz Neto / Resumo: Adesão tem sido a meta das pesquisas Odontológicas nas últimas décadas. Para determinar se os mais recentes sistemas adesivos denominados como MULTI-USO poderiam ser utilizados associados a diferentes marcas comerciais de resina composta, em dentina, foram realizados testes de resistência ao cisalhamento. Setenta e dois corpos de prova foram confeccionados utilizando-se dentes pré-molares humanos íntegros, embutidos em resina acrílica, expondo-se a dentina por tratamento com lixas d'água de granulações 180, 400 e 600. Os corpos de prova foram divididos em três grupos: Grupo 1 Scotchbond Multi-Purpose (3M), grupo 2 - Optibond Light Cure (Kerr) e grupo 3 - Optibond Dual Cure (Kerr). Todos os grupos foram subdivididos em sub-grupos de 8 dentes, nos quais foram inseridas as resinas compostas: a-Z1 00 (3M do Brasil), bPrisma APH (Dentsply) e c- Herculite XRV(Kerr). Os corpos de prova foram submetidos à ciclagem térmica e após 24 horas de armazenamento em água destilada 370C, aos testes de resistência ao cisalhamento em máquina lnstron 4301 seguidos de análise em estereomicroscópio Technivai-Carl Zeiss de aumento para avaliar o tipo de fratura e, análise em microscopia eletrônica de varredura (M.E.V.). A aplicação do modelo estatístico de análise de variância permitiu a constatação de que o fator Adesivo apresentou um valor significante (p<0,05) independente do fator Resina, tendo o adesivo Optibond Light Cure propiciado a maior resistência média ao cisalhamento (15,446 MPa), seguido do Scotchbond Multi-Purpose (13,340 MPa) e do Optibond Dual Cure (1 0,019 MPa). A interaçâo Adesivo x Resina apresentou um valor estatisticamente significante (p<0,05), onde os melhores resultados foram obtidos entre as resinas Z100 e Herculite XRV com o adesivo Optibond Light Cure, e entre a Resina APH com o adesivo Scotchbond Multi-Purpose. Concluímos que o adesivo Optibond... / Abstract: Recent bonding systems have been advocated as "multi-purpose bonding agents". The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose / Mestre
137

Análise da espessura da película de cimentos de ionômero vítreo e fosfato de zinco, empregados na cimentação de coroas totais metálicas, preparadas "in vivo" /

Pavanelli, Carlos Augusto. January 1997 (has links)
Orientador: José Eduardo Junho de Araújo / Banca: Eulália Maria Martins Silva / Banca: Marcos Yasunóri Maekawa / Resumo: A presente pesquisa consistiu em analisar a espessura da película de cimentos de ionômero vítreo (Vidrion C, SS WHITE, Brasil; Ketac Cem, ESPE, Alemanha) in vivo, comparando os resultados com um cimento de fosfato de zinco (Lee Smith, TELEDYNE WATER PIK, USA), na cimentação de coroas totais metálicas. Foram utilizados 21 dentes íntegros, com exodontia indicada para fins ortodônticos, que foram preparados para receber coroa total metálica. O processamento laboratorial das fundições, foi feito em laboratório comercial, de forma padronizada. Todas as coroas foram aliviadas internamente, através da prévia aplicação de cinco camadas de verniz espaçador sobre os troquéis. As cimentações, foram feitas, inicialmente sob pressão digital, seguida por pressão de assentamento pela oclusão, com um mordente de madeira de laranjeira, interposto entre a coroa e a arcada antagonista. Os resultados mostraram, pelo teste estatístico ANOVA, valores semelhantes para os três cimentos, ao nível de 1%. Entretanto, quando a espessura da película do cimento foi analisada sob as variáveis cimento e posição de mensuração na superfície do dente preparado, encontrou-se que nas paredes axiais, havia diferença entre o cimento Lee Smith e o Vidrion C, onde os valores para o Vidrion foram significativamente menores. Nas demais posições analisadas, não houve diferença significante ao nível de 5%. Quando esses mesmos valores foram apreciados através de representação gráfica (diagrama, do tipo BOX-PLOT), do cimento em função da posição de mensuração, observou-se, no caso do cimento de fosfato de zinco, uma tendência de distribuição dos valores, por toda a faixa compreendida entre o valor máximo e o valor mínimo da película. Os cimentos de ionômero vítreo, tenderam a concentrar seus valores, em relação à faixa de distribuição, a níveis mais baixos que o cimento de fosfato de zinco. O Vidrion C, em particular, foi o que... / Abstract: This study evaluated the film thicknesses of two GIC cements (Vidrion C, SS WHITE, Brazil; Ketac Cem, ESPE, Germany) and one zinc phosphate cement (Lee Smith, TELEDYNE, USA), used for final cementation of complete metal crowns. Twenty-one teeth scheduled for extraction due to orthodontic treatment were prepared for complete metal crowns. Dies were relieved with 5 layers of die varnish spacer. The crowns were manufactured by a commercial laboratory (with standardized procedures as much as possible) and cemented first with finger pressure and later by occlusion pressure using orange wood sticks. Results submitted to an ANOVA test showed that all cements had a similar behavior showing no significant statistical differences (p<0.01). A film thickness analysis of 7 selected preparations sites, showed that only axial positions, presented differences between Lee Smith and Vidrion C cements, the latter presenting lower significant values. For other positions studied, the three cements showed no significant statistical differences (p<0.05). Technical exploratory analysis of data by a BOX PLOT graphic showed for the ZPC a broad film thickness value distributions (from the highest to the lowest values) related to type of cement and measurement values. For glass ionomer cement the graphic presented values concentrating at lower levels than zinc phosphate cement. This was still more evident for the Vidrion C cement / Mestre
138

Avaliação "in vitro " da adaptação cervical de coroas totais metálicas, variando os preparos dos términos cervicais, aliviando ou não as superfícies internas das coroas e empregando diferentes cimentos definitivos /

Bottino, Marco Antonio. January 1998 (has links)
Resumo: Este trabalho avaliou a qualidade das adaptações cervicais de coroas totais metálicas, tendo como fonte de variação: a) o término do ombro cervical do preparo - biselado, inclinado em 1350; reto em 900, chanfro e gume de faca; b) o alívio ou não das superfícies internas das coroas; e, c) os tipos de agente de cimentação permanente, cimentos - fosfato de zinco Harvard; ionômero de vidro Ketac-Cem, policarboxilato de zinco Durelon e resinoso Panavia Ex. Inicialmente, foram confeccionados corpos-de-prova em modelos-padrão de aço inoxidável usinado, de acordo com o tipo de preparo dos términos cervicais experimentais. As cápsulas metálicas de aço inoxidável preparadas, tendo ou não alívio da superfície interna de 30 micrometros até a distância de 0,5 mm do limite do término cervical, justapunham-se precisamente e formavam um conjunto com adaptação e assentamento exatos. Estas foram cimentadas nos corpos-de-prova com os diferentes agentes cimentantes, os quais foram manipulados de acordo com as instruções dos fabricantes. Desenvolveram-se metodologias de reaproveitamento dos corpos-de-prova, estabilidade das cápsulas impedindo seu deslocamento durante a tomada das medidas e mensuração precisa. Concluiu-se que: a) as melhores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros: lâmina de faca, ombro inclinado em 1350 e chanfro; b) as piores médias de adaptações cervicais, semelhantes entre si, foram obtidas em modelos-padrão com ombros reto em 900 e degrau em 900 com bisel de 450; c) houve melhora significativa na adaptação quando cápsulas metálicas foram cimentadas com alívio de sua superfície interna; d) os cimentos...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study assessed the quality of cervical adaptation in full metal crowns, with a variation in: a) the type of cervical preparation- beveled shoulder, 135-degree preparation, 90-degree shoulder, chamfer and knife edge; b) internal surfaces of the crowns with or without relief; c) the types of luting agents and their commercial brands- Harvard zinc phosphate, Ketac-Cem glass ionomer, Durelon zinc polycarboxylate and Panavia Ex resinous. Initially, machined stainless steel models were made according to each experimental margin design. Stainless steel metal caps were prepared with or without a 30-micrometer spacing of their internal surfaces, kept away 0.5 mm of the cervical end limit; they were precisely fitted, making a set with exact adaptation and seating. The caps were cemented on the specimens by means of different luting agents , handled according to the manufacturer's instructions. Methods were developed to reuse the specimens. Precise measures were obtained by preventing caps from moving during measurements. The conclusions were: a) the best mean of cervical adaptation, similar to each other , was obtained in standard models with preparations : knife edge, 1350 shoulder and chamfer; b) the worst mean of cervical adaptation, similar between them , was obtained in standard models with: straight shoulder and beveled shoulder; c) there was a significant improvement in adaptation when the metal caps were cemented with relief in their internal surface; d) cements presented decreasing cervical adaption, in the following order: Ketac-Cem, Harvard, Durelon and Panavia Ex; and, e) the methodology used allowed work with positive values of cervical adaptation.
139

Avaliação da efetividade de cimentos resinosos auto-adesivos aplicados sob diferentes pré-tratamentos da dentina radicular na resistência adesiva de pinos de fibra de vidro /

Lima, Luiz Rafael Calixto. January 2013 (has links)
Orientador: Marcelo Ferrarezi de andrade / Banca: Edson Alves de Campos / Banca: José Roberto Cury Saad / Banca: Paulo Sérgio Quagliatto / Banca: Mânio de Carvalho Tibúrcio / Resumo: A retenção de pinos pré-fabricados de fibra de vidro utilizados na restauração de dentes com tratamento endodôntico é baseada na sua união às superfícies das paredes do canal radicular por meio dos agentes de fixação resinosos. Os cimentos resinosos auto-adesivos surgiram recentemente com o objetivo de simplificar o procedimento de cimentação, porém seu desempenho clínico ainda é controverso na literatura. Assim, o propósito desse trabalho é avaliar a efetividade de cimentos autoadesivos sob diferentes condições de tratamento da dentina na resistência à extrusão de pinos de fibra de vidro cimentados intrarradicularmente. Foi avaliada a resistência adesiva (push-out) de pinos de fibra de vidro utilizando cimentos resinosos auto-adesivos e, diferentes substâncias para o tratamento dentinário (ácido poliacrílico 11,5%; EDTA 17% e hipoclorito de sódio) previamente ao procedimento de cimentação. Foi avaliado também o tipo de falha entre o pino/cimento/dentina através de microscopia óptica. Foram utilizados 216 unidades experimentais, em forma de discos com aproximadamente 1 mm de espessura, retirados de 72 raízes bovinas restauradas com retenções intra-radiculares. Foi utilizada uma máquina de ensaios universais MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para Mpa. Os dados foram submetidos ao teste kruskall wallis com post-hoc com teste dunn, com nível de significância de 5%. Os resultados mostraram que o pré-tratamento dentinário não influenciou na resistência adesiva, e que o cimento auto-adesivo RelyX U100 parece ser uma opção viável na cimentação de pinos de fibra. / Abstract: The retention of prefabricated fiberglass posts used in the restoration of endodontically treated teeth is dependent on their bond between the surface of the post and the root canal walls by means of resin cements. The self-adhesive resin cements have recently introduced to simplify the procedure for cementing, but their clinical performance is still controversial in the literature. Thus, the objective of this study is to evaluate the effectiveness of self-adhesive cements under different pretreatment of dentin in the resistance to extrusion of fiberglass posts. Prior to cementing procedure, the pre-treatment of dentin was performed with 11.5% polyacrylic acid, 17% EDTA or sodium hypochlorite. The type of failure between the post/cement/dentin was evaluated by steriomicroscopy. Two hundred and sixteen bovine dentin discs were used. The disks had approximately 1 mm of thickness and they were taken from 72 bovine roots restored with intraradicular retentions. It was employed a universal testing machine MTS 810 Material Test System at a speed of 0.5 mm/min-1 with a load cell of 50 kg to evaluate the push-out resistance in different thirds of each sample . The values of resistance in kgf were converted to Mpa. Data were submitted to Kruskal-Wallis test with Dunn post-hoc test with significance level of 5%. The results showed that pre-treatment had no effect on dentin bond strength, and that the self-adhesive cement RelyX U100 appears to be a viable option in the cementation of fiber post. / Doutor
140

Avaliação do PH e da densidade óptica do corante azul de metileno tamponado e não tamponado após o contato com diferentes cimentos endodônticos /

Gomes, Ana Paula Martins. January 2005 (has links)
Resumo: O objetivo deste trabalho foi avaliar o pH e a densidade óptica das soluções de azul de metileno a 1% e 2% (tamponadas e não tamponadas) após a imersão de três cimentos endodônticos. Foram preparados oitenta espécimes de cada cimento endodôntico (Endofill, AH Plus e Sealapex), os quais foram imersos nas soluções corantes. As soluções foram analisadas antes e após a imersão dos materiais nos períodos de tempo de 0, 24, 48 e 72h. Foram realizadas avaliações do pH utilizando um pHmetro e da densidade óptica utilizando um espectofotômetro ajustado em 596nm. Os dados de pH foram analisados através de estatística descritiva e os dados da densidade óptica foram analisados pela ANOVA e teste de Tukey 5%. Pôde-se verificar que as soluções corantes de azul de metileno tamponadas e não tamponadas apresentaram pequena variação nos valores de pH e densidade óptica antes do contato com os cimentos endodônticos. As soluções corantes não tamponadas apresentaram valores de pH menores que as tamponadas, independentemente do contato com qualquer cimento endodôntico. Os cimentos endodônticos promoveram alterações nos valores de pH das soluções corantes, sendo que as maiores alterações ocorreram nas soluções não tamponadas. Ocorreram alterações nos valores da densidade óptica das soluções corantes tamponadas e não tamponadas nos diferentes períodos de tempo de análise, sendo diferentes para cada cimento endodôntico utilizado / Abstract: The aim of this study was to evaluate pH and optical density of 1 and 2% methylene blue dye solutions (buffering and non buffering) after three endodontics sealers immersion. Eighty specimens of each endodontic sealer were prepared (Endofill, AH Plus and Sealapex). Solutions were analyzed before and after immersion in 0, 24, 48 and 72 hours. pH were accomplished using pHmetro and optical density evaluations were accomplished in spectrophotometer adjusted in 596 nm. pH data were analyzed through descriptive statistics and optical density data were analyzed through ANOVA and Tukey 5% tests. It could be verified that the dye solutions of methylene blue (buffering and non buffering) presented stability in pH values and optical density before contact with endodontics sealers. pH of non buffering dye solutions were smaller than the buffering, independently of contact with any endodontic sealer. The endodontic sealers promoted increase in the pH of dye solutions in different periods, and the largest alterations happened in non buffering solutions. It happened variation in optical density values of buffering and non buffering dye solutions for each endodontic sealer used

Page generated in 0.0932 seconds