Spelling suggestions: "subject:"caimentos dentários"" "subject:"sentimentos dentários""
171 |
Physicochemical and biological properties of Biodentine associated with radiopacifiers /Ochoa Rodríguez, Victor Manuel January 2018 (has links)
Orientador: Gisele Faria / Resumo: BiodentineTM (BD) apresenta bioatividade, biocompatibilidade e propriedades físico-químicas adequadas; no entanto, não possui radiopacidade adequada. Os objetivos foram avaliar (1) a radiopacidade de BD e BD associado com 15% de tungstato de cálcio (BDCaWO4) ou óxido de zircônio (BDZrO2), empregando sistemas de radiografia convencional e digital; e (2) as propriedades físico-químicas de tempo de presa, pH e solubilidade, e as propriedades biológicas de citocompatibilidade e potencial para induzir mineralização desses cimentos. Para a avaliação da radiopacidade, cada corpo de prova foi radiografado ao lado de uma escada de alumínio usando filme oclusal, placa de fósforo ou sensores digitais. As radiografias convencionais foram digitalizadas por câmera fotográfica ou scanner. Os valores médios de cinza dos materiais foram expressos em milímetros de alumínio (mm Al). A solubilidade foi avaliada após 7 dias de imersão dos espécimes em água destilada e expressa em percentagem de perda de massa. O tempo de presa foi avaliado empregando a agulha de Gillmore (105 ± 0,5 g) e o pH foi mensurado com um medidor de pH. A citocompatibilidade e a bioatividade celular foram avaliadas em células de linhagem osteoblástica (Saos-2) utilizando os ensaios de metiltetrazólio (MTT), vermelho neutro (NR), atividade de fosfatase alcalina (ALP) e coloração de vermelho de alizarina. Os dados foram avaliados utilizando ANOVA de um fator e pós-teste Tukey ou ANOVA de dois fatores e pós-teste de Bonferron... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: BiodentineTM (BD) presents bioactivity, biocompatibility and suitable physicochemical properties; however, it does not have adequate radiopacity. The objectives were to evaluate (1) the radiopacity of BD and BD associated with 15% calcium tungstate (BDCaWO4) or zirconium oxide (BDZrO2), employing conventional and digital radiography systems; and (2) the physicochemical properties of setting time, pH and solubility, and biological properties of cytocompatibility and potential to induce mineralization of these cements. For radiopacity evaluation, each cement specimen was radiographed alongside an aluminum step-wedge using occlusal film, photostimulable phosphor plates or digital sensors. The conventional radiographies were digitized by digital photographic camera or scanner. Mean grey values of materials were expressed in millimeters of aluminum (mm Al). Solubility was evaluated after 7 days of specimens' immersion in distilled water and expressed as percentage of mass loss. Setting time was evaluated employing a Gillmore needle (105 ± 0.5 g) and pH was evaluated with pH meter. The cytocompatibility and cell bioactivity were evaluated in osteoblasts-like cells (Saos-2) using methyl-thiazol-tetrazolium (MTT), neutral red (NR), alkaline phosphatase (ALP) activity and alizarin red staining assays. The data were evaluated using one-way ANOVA and Tukey post-test or two-way ANOVA and Bonferroni post-test (α=0.05). BD radiopacity was below 3 mm Al and BDZrO2 and BDCaWO4 was above 3 mm... (Complete abstract click electronic access below) / Mestre
|
172 |
Estudo dos mecanismos envolvidos na migração celular induzida pelo MTA para cavidade peritoneal de camundongos /Gomes, Alessandra Cristina. January 2006 (has links)
Orientador: Sandra Helena Penha de Oliveira / Banca: Carlos Ferreira dos Santos / Banca: Pedro Felício Estrada Bernabé / Resumo: O objetivo deste trabalho foi investigar os mecanismos envolvidos na migração de neutrófilos induzida pelo MTA para cavidade peritoneal de camundongos. Observouse que o MTA induziu migração de neutrófilos de maneira dose-dependente (0,5; 5; 50 e 100 mg/cavidade), alcançando o pico de migração 6 horas após a injeção do estímulo com a dose de 50 mg/cavidade. Esta migração foi parcialmente inibida pelo pré-tratamento dos animais com dexametasona (1 mg/Kg), BWA4C (50 mg/Kg) e U75302 (0,5 mg/Kg). Diferentemente, a Indometacina (5 mg/Kg) foi inefetiva neste processo. Verificou-se também que os animais estimulados com MTA (50 mg/cavidade) apresentaram uma liberação significativa de IL-1ß e MIP-2 no exsudato peritoneal. O pré-tratamento com Tioglicolato aumentou em cerca de 380% a população de macrófagos na cavidade peritoneal, potencializando a migração de neutrófilos induzida pelo MTA (p<0,05). O pré-tratamento com composto 48/80 depletou cerca de 75% a população de mastócitos, diminuindo a migração de neutrófilos (p<0,05). A injeção de MTA na bolha de ar subcutânea induziu uma migração de neutrófilos menor comparada à cavidade peritoneal. Estes resultados confirmam a participação de mastócitos e macrófagos na migração de neutrófilos induzida pelo MTA. A injeção de sobrenadante de macrófagos e mastócitos estimulados com MTA na cavidade peritoneal de camundongos causou significante migração de neutrófilos (p<0,05), que foi parcialmente inibida pelo pré-tratamento das células por dexametasona (10 æMolar), BWA4C (100 æMolar) e U75302 (10 æMolar) sugerindo a liberação por essas células de LTB4 e citocinas e/ou quimiocinas. Confirmando esses dados,...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to investigate the mechanism involved in the neutrophil migration induced by MTA into peritoneal cavity in mice. It was observed that MTA induced a dose dependent neutrophil migration (0.5, 5, 50 and 100 mg/cavity), achieving the peak 6 hours after the stimulation with 50 mg/cavity. Neutrophil migration was inhibited by the pre-treatment with dexamethasone (1 mg/Kg), BWA4C (50 mg/Kg) and U75302 (0,5 mg/Kg). Differently indometacin (5 mg/Kg) was ineffective in this process. It was seen that the animals stimulated with MTA (50 mg/cavity) showed a significative amount of IL-1ß and MIP-2 released to the peritoneal exudate. The pretreatment with Thioglycolate 3% increased 380% the macropahge population into the peritoneal cavity, increasing the MTA-induced neutrophil migration (p<0.05). The pretreatment with 48/80 compound decreased 75% the mast cell population in the peritoneal cavity and decreased the MTAinduced neutrophil migration (p<0.05). The injection of MTA in the air-pouch cavity induced a neutrophil migration, however, the recruitment was shorter than that induced into the peritoneal cavity. These data confirm the participation of the mast cell and macrophages in the MTA-induced neutrophil migration. The injection of MTA-stimulated macrophages and mast cells supernatants into the mice peritoneal cavity induced a significant neutrophil migration that was inhibited by the pretreatment with dexamethasone (10 æMolar), BWA4C (100 æMolar) and U75302 (10 æMolar) suggesting the release of LTB4 and cytokines and/or chemokines by these cells. Besides, macrophages and mast cells MTA-induced were able to express in vitro IL-1ß MIP-2 and 5-LO mRNA. In conclusion, the neutrophil migration into mice peritoneal cavity induced by MTA was dependent on mast cells and macrophages, which expressed IL-1ß, MIP-2 and LTB4. / Mestre
|
173 |
Avaliação 'in vitro' da infiltração marginal de restaurações indiretas com resina composta em molares decíduos cimentadas com dois tipos de cimentos / In vitro evaluation of marginal leakage of indirect restorations with composed resin in primary molars, cemented with two types of cementsOliveira, Thais Marchini de 20 February 2003 (has links)
O objetivo deste trabalho foi avaliar in vitro" a infiltração marginal em restaurações indiretas Classe II, realizadas com resina composta Filtek Z250 e cimentadas com dois tipos de cimentos: Enforce e RelyX Cimento Resinoso Adesivo. A amostra experimental constituiu-se de vinte e quatro segundos molares decíduos. Foram confeccionadas cavidades estritamente mesiais e distais em todos os dentes e realizados todos os procedimentos para a confecção das restaurações indiretas. Posteriormente realizou-se a cimentação das restaurações com cimentos resinosos de presa dual. Após esta fase, foram realizados os procedimentos de termociclagem e penetração do corante. Cada dente foi seccionado em cortes de 1,0mm e em seguida, obtida a imagem scaneada de cada corte. Realizou-se a medição linear da infiltração do corante em milímetros por meio de um software" para este fim. Os resultados foram submetidos à análise pelo teste t pareado", adotando nível de significância de 5%. Observou-se, neste estudo, que nenhum dos materiais testados foi capaz de impedir completamente a microinfiltração. O Enforce apresentou os menores valores de infiltração, no entanto não existiram diferenças estatisticamente significantes em relação aos dois materiais estudados. / The aim of the present investigation was to evaluate the microleakage of Class II indirect restorations with composed resin Filtek Z250 and cemented with two types of cements: Adhesive Cement Enforce and RelyX Adhesive Resinous Cement. The experimental sample consisted of twenty-four seconds primary molars. Mesiais and distais cavities were prepared in all the teeth and accomplished the procedures to make indirect restorations. After, they were cemented with two types of resinous cements. Soon after that, the specimes were thermocycled, immersed in 0,5% basics fuchsin and sectioned. The microleakage was measured by a software and assessed the dye penetration at the cervical margins. The results were submitted to the analysis by test t dependet". The results demonstrated that none of the tested materials was capable to impede the microleakage completely, and there was no significant differences in relation to the two studied materials.
|
174 |
Effect of CAD/CAM abutment height and cement type on the retention of zirconia crowns / Efeito da altura do pilar CAD / CAM e tipo de cimento na retenção de coroas de zircôniaSilva, Camila Perfeito Evangelista da 07 May 2018 (has links)
Aim: To evaluate the effect of different Ti-base abutment heights and cement type on the pullout retention of zirconia-based restorations. Methods: Identical crowns were designed in a CAD software to fit two different Tibase abutment heights, as follows (n=10/group): (i) 4-mm-height Ti-base abutment (Tall), and (ii) 2.5-mm-height Ti-base abutment (Short). Four cement types were selected: (i) Temporary cement (Provisional); (ii) Glass-ionomer cement (Meron); (iii) self-adhesive resin cement (U200), and (iv) conventional resin cement (Ultimate) with universal adhesive for treatment of titanium and zirconia substrates. Pull-out testing was performed in a universal testing machine. Data were statistically evaluated through two-way analysis of variance following post-hoc comparisons by Tukey test. Results: Tall Ti-base abutments demonstrated similar retention to short abutments when data is collapsed over cement (p>0.74). Data evaluation as a function of cement type demonstrated the superiority of resin-based cements relative to provisional and glass-ionomer groups (p<0.01). Retentiveness data as a function of both factors demonstrated similar force to dislodgment between tall and short abutments for all within cement comparisons (p>0.42), except for U200 (p=0.032). Also, tall abutments cemented with Ultimate evidenced higher pull out values than U200 (p=0.043), and both were significantly more retentive than tall provisional and meron (p<0.001). No significant difference was observed between U200 and Ultimate cements for short abutments (p=0.758), and both presented statistically higher pullout values than provisional and glass-ionomer (p=0.001). Conclusions: While Ti-base abutment height have not influenced zirconia superstructure retentiveness, resin-based cements significantly evidenced higher retention than glass ionomer and temporary cements. / Objetivo: Avaliar o efeito de diferentes alturas de interface de Titânio (Ti) e diferentes tipos de cimento na retenção de coroas de zircônia. Métodos: Coroas idênticas foram projetadas em um software de CAD capaz de adaptar duas alturas diferentes do pilar de interface de Ti: cada grupo foi composto de 10 amostras conforme se segue: (i) interface de Ti de 4 mm de altura (alto) e (ii) interface de 2,5 mm de altura (curto). Foram selecionados quatro tipos de cimento: (i) cimento temporário (Provisional); (ii) Cimento de ionômero de vidro (Meron); (iii) cimento resinoso auto-adesivo (U200) e (iv) cimento resinoso convencional (Ultimate) com adesivo universal para tratamento de substratos de titânio e zircônia. O teste de tração foi realizado em uma máquina de ensaio universal. Os dados foram avaliados estatisticamente através de análise de variância a dois critérios, após comparações pós-hoc pelo teste de Tukey. Resultados: As interfaces de Ti demonstraram retenção semelhante aos pilares curtos quando os dados foram colapsados sobre o cimento (p> 0,74). A avaliação dos dados em função do tipo de cimento demonstrou a superioridade dos cimentos à base de resina em relação aos grupos de cimentos temporário e de ionômero de vidro (p <0,01). Os dados de retenção em função de ambos os fatores demonstraram força semelhante ao deslocamento, entre pilares altos e curtos, para todos dentro das comparações de cimento (p> 0,42), exceto para U200 (p = 0,032). Além disso, os pilares altos cimentados com Ultimate evidenciaram maiores valores de tração do que os cimentados com U200 (p = 0,043), e ambos foram significativamente mais retentivos do que o pilar alto cimentado com cimento Provisional e o Meron (p <0,001). Não foi observada diferença significativa entre os cimentos U200 e Ultimate para pilares curtos (p = 0,758) e ambos apresentaram valores de tração estatisticamente mais elevados que os cimentos de ionômero de vidro e cimento temporário (p = 0,001). Conclusões: Embora a altura da interface de Ti não tenha influenciado a retenção das coroas de zircônia, os cimentos resinosos resultaram em maior retenção do que o ionômero de vidro e cimentos temporários.
|
175 |
Capacidade de vedamento de diferentes materiais usados como barreira protetora cervical no clareamento interno colocado em duas alturas com respeito a Junção Amelocementaria / In vitro sealing capacity of different materials used as protective cervical barrier in internal bleaching placed in two heights respect to the cementoenamel junctionOrdonez Aguilera, Juan Fernando 03 July 2013 (has links)
O objetivo deste trabalho foi avaliar a efetividade do vedamento apical e linear de diferentes materiais utilizados como barreira protetora cervical (BPC) no clareamento interno, localizados ao mesmo nível e 1mm acima da junção amelocementária (JAC). Cento doze dentes bovinos foram divididos em sete grupos de acordo com o material de BPC utilizado, além de um grupo controle, e em dois subgrupos de acordo com a localização, sendo assim distribuídos: grupo GRC com resina composta sem sistema adesivo (Z250); grupo GVR com Cimento de Ionômero de Vidro (CIV) convencional (Vidrion R); grupo GVB com CIV modificado por resina de forramento (Vitrebond); grupo GVTR com CIV modificado por resina restaurador (Vitremer); grupo GCZ com Cimento de Fosfato de Zinco (CIMENTO DE ZINCO); grupo GCT com material restaurador provisório (Coltosol); grupo GCF com material provisório fotopolimerizável (Clip F); e grupo controle com Gutapercha e cimento selador (Fillapex). Os dentes foram clareados pela técnica walking bleach durante sete dias e após esse período foram corados durante 48hrs, enquanto armazenados com temperatura de 37oC e umidade a 100%. Foi realizada avaliação através de inspeção visual. A análise estatística foi feita através da análise de variância a dois critérios (ANOVA-2) e teste de Tukey. Os grupos experimentais revelaram que o único fator que representou importância no vedamento apical (F=26,42; p=0,00) e linear (F=29,73; p=0,00) foi o tipo de material empregado, independente da sua localização. Os grupos GRC e GCZ apresentaram os piores valores de vedamento e apresentaram diferença estatisticamente significativa (p=<0,05) quando comparados com os outros grupos e com o grupo controle. Os melhores resultados foram encontrados nos grupos GCT, GCF, GVB, GVTR e GVR, porém sem diferença estatisticamente significativa entre eles (p=<0,05) e com o grupo controle. Através do teste de correlação de Spearman verificou-se correlação positiva (r=0,911; p=0,00) entre a infiltração apical e linear. Os resultados sugerem que a capacidade de vedamento linear e apical da BPC varia de acordo com o material aplicado, independentemente da localização em relação à JAC. / The aim of this study was to evaluate the apical and linear sealing in different materials placed as a protective cervical barrier (BPC) in internal bleaching at Cementoenamel junction (CEJ) level and 1mm above. 112 bovine teeth were divided into seven groups according to the material to be placed as PCB and a control group, and two subgroups each in relation to their JAC level position: GRC Resin composite without adhesive system (Z250); GVR, Conventional glass ionomer cement (GIC) (VIDRION R); GVB, Lining resin modified GIC (VITREBOND); GVTR, Restorative resin modified GIC (VITREMER); GCZ, Zinc phosphate cement (CEMENTO DE ZINCO); GCT, Temporary restorative material (COLTOSOL), GCF, Light curing temporary material (CLIP F). A control group with gutta-percha and sealer cement (Fillapex) with the two positions was performed too. The teeth were bleached by walking bleach technique for seven days and then stained for 48hrs while stored at 37oC and humidity to 100%. Visual inspection was used to evaluate the specimens. Statistical analyses were performed with the two-factor analysis of variance (ANOVA-2) and Tukey test. The experimental groups showed that the main factor for apical (F=26.42, p=0.00) and linear (F=29.73; p=0.00) sealing was the type of material used regardless of their location. The experimental groups GRC and GCZ had the worst sealing values and were statistically significant different (p= < 0.05) with the other groups and the control group. The groups GCT, GCF, GVB, GVTR and GVR showed better result with no significance difference between them and the control group (p=< 0,05). The Spearman rank correlation coefficient revealed the positive significant correlation (r = 0.911, p = 0.00) between the apical and linear leakage. These results suggest that the ability of linear and apical sealing of PCB, varies according to the applied material regardless of the CEJ position.
|
176 |
Influência da ciclagem com cargas dinâmicas na microinfiltração de coroas metalocerâmicas cimentadas com três tipos de cimentoRossetti, Paulo Henrique Orlato 29 April 2003 (has links)
O propósito deste estudo foi avaliar "in vitro" as mensurações e possíveis correlações entre discrepância de assentamento, abertura marginal e padrão de microinfiltração, em coroais metalocerâmicas cimentadas com três tipos de agentes cimentantes: fosfato, ionômero e cimento resinoso dual. Trinta dentes pré-molares humanos extraídos foram preparados para coroas metalocerâmicas e as fundições foram realizadas com liga de Ni-Cr. As amostras foram divididas em três grupos, de acordo com o agente cimentante e a cimentação foi realizada sob uma carga de 5Kg por 10 minutos e as amostras armazenadas em água por 24hs. A discrepância de assentamento foi registrada antes e após a cimentação em um microscópio óptico com precisão de 0,001micrometro. Metade dos espécimes dentro de cada grupo foi submetida ao teste de fadiga cíclica (50.000 ciclos, 2,5Hz). As coroas foram seccionadas longitudinalmente no sentido vestíbulo-lingual e na interface coroadente-cimento foi aplicado um corante (rodamina B) por 15 segundos. A penetração do corante foi quantificada ao longo da interface sob um microscópio óptico (80 vezes de aumento) e, posteriormente, as amostras foram preparadas para microscopia eletrônica de varredura a fim de quantificar a abertura marginal e a qualidade da interface. Os resultados de discrepância de assentamento foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, sem diferença estatística. Foram encontradas diferenças estatisticamente significantes entre a discrepância de assentamento e a abertura marginal para os três cimentos. Os resultados de infiltração foram maiores para o cimento fosfato de zinco, seguido do ionômero de vidro e resinoso, com diferenças estatisticamente significantes. A ciclagem mecânica aumentou a infiltração marginal para o cimento fosfato de zinco, com diferença estatisticamente significativa em relação ao cimento ionomérico e resinoso. A análise ao microscópio eletrônico de varredura detectou melhor qualidade de união na interface dente-cimento para o sistema resinoso, seguido pelo cimento ionomérico e resinoso. / The purpose of this study was to verify "in vitro" measures and possible correlations between seating discrepancy, marginal opening and microleakage pattern under total metallic crowns cemented with three types of luting agents: phosphate, glass-ionomer and resin dual cement. Thrirty extracted human premolars teeth were prepared for total metalloceramic crowns and castings obtained with a Ni-Cr alloy. Samples were ramdomly assigned for three groups in according to each luting agent: zinc phosphate (S.S.White), resin-modified glass-ionomer (Vitremer-3M) or a dual resin cement (Enforce-Dentsply). Cementation was done under a 49N load for 10 minutes and water stored for 24hs. Vertical discrepancy was registered before and after cementation in an optical microscopy with the accuracy of 0,001mm). Half of the specimens within each group was submitted to a cyclic loading test (50000 cycles, 2,5Hz). Crowns were longitudinally seccionated in a bucco- lingual plane at the tooth-cement-crown interface and dye solution (rodhamine B) was apllied to tooth-cement- interface for 15 seconds The linear stain penetration along tooth-cement was quantified. under a light microscope (80X magnification) and then samples were prepared for scanning electronic microscope in order to quantify marginal opening and the quality of interface. The results for seating discrepancy were higher for zinc phosphate, followed by glass-ionomer and resin cement, with no statistical difference. Statistically significant differences were found between seating discrepancy and marginal opening for the three cements. Microleakage results were higher for zinc phosphate, followed by glass-ionomer and resin cement, with statiscally significant differences. Fatigue loading rinsed marginal leakage for zinc pohsphate, with statiscally significant difference in respect to glassionomer and resin cement. Scanning electron microscope analysis showed better marginal quality at the tooth-cement-restoration interface for resinous cement,followed by glass-ionomer and zinc phosphate cement.
|
177 |
Adesão de um cimento resinoso a uma cerâmica feldspática : avaliação da resistência adesiva, ângulo de contato e ph, em função de diferentes técnicas de condicionamento /Amaral, Regina. January 2008 (has links)
Orientador: Luiz Felipe Valandro / Banca: Marco Antonio Bottino / Banca: Roberto Ruggiero Braga / Resumo: O objetivo deste trabalho foi avaliar a durabilidade da resistência adesiva entre um cimento resinoso e uma cerâmica feldspática, o pH e o ângulo de contato da superfície cerâmica, submetida à diferentes tratamentos de superfície. Para análise do pH de superfície foram confeccionados 96 discos (8X3mm) da cerâmica feldspática (Vita VM7), os quais, foram divididos em 12 grupos (n=8): CS1- sem condicionamento; CS2- ácido fluorídrico (HF) 9% 1 min; CS3- CS2+lava/seca; CS4- CS3+silano (S); CS5- HF 4% 1 min; CS6- CS5+lava/seca; CS7- CS6+silano; CS8- HF 5% 1 min; CS9- CS8+lava/seca; CS10- CS9+silano 20 5min; CS11- CS9+neutralização+lava/seca+ultra-som; CS12- CS11+siano. Após, o pH foi medido com um peagâmetro digital. Para a análise do ângulo de contato foram confeccionados 40 discos com as mesmas dimensões (n=8): CS1- sem condicionamento; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+neutralização+lava/seca+ultra-som. As medidas foram realizadas com um Goniômetro. Para a resistência de união, foram confeccionados 40 blocos (6,4X6,4X4,8mm), os quais foram submetidos aos tratamentos (n=10): CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+neutralização+lava/seca+ultra-som. Os espécimes foram armazenados em água destilada (37°C) por 24h e seccionados nos sentidos x e y. Os corpos-deprova obtidos foram divididos em 2 condições (Seco- ensaio imediato; TCarmazenagem + termociclagem) e submetidos ao teste de microtração. Na análise do pH, CS6 obteve o maior resultado e CS5, CS8 e CS2, obtiveram os menores valores estatisticamente. Para o ângulo de contato, CS1 obteve médias maiores comparados aos outros grupos. Para resistência de união, CS2=CS1>CS3=CS4, independente do fator armazenagem. Somente o CS4 sofreu redução na resistência adesiva após TC. Conclui-se que a neutralização parece afetar negativamente a resistência adesiva... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the tensile bond strength of a resin-based cement to a feldspathic ceramic (Vita VM7), the pH and the contact angle on a ceramic surface, after submitted to surface conditioning methods. To analyze the pH of the ceramic surface, ninety six disks (8x3mm) of VM7 were fabricated and divided into 12 groups (n=8) according to each treatment condition (CS): CS1- without surface conditioning; CS2- hidrofluoridric acid (HF) 9% 1 min; CS3- CS2+wash/dry; CS4- CS3+silane (S); CS5- AHF 4% 1 min; CS6- CS5+wash/dry; CS7- CS6+silane; CS8- HF 5% 1 min; CS9- CS8+wash/dry; CS10- CS9+silane 5min; CS11- CS9+neutralizer+wash/dry+ ultrasonic cleaning; CS12- CS11+silane. Then, pH was measure using a digital peagameter. Another forty disks (8X3mm) were fabricated and divided into 5 groups to analyze the contact angle: CS1-without conditioning; CS2- HF 9%; CS3- HF 4%; CS4- HF 5%; CS5- HF 5%+ neutralizer +wash/dry+ultra-som, all groups were analyzed by means of a Goniômetro. Forty blocks (6,4x6,4x4,8mm) were fabricated, divided into 5 groups (n=10) and submitted to surface treatments to evaluate the bond strength: CS1- HF 9% 1 min; CS2- HF 4% 1 min; CS4- HF 5% 1 min; CS5- CS3+ neutralizer +wash/dry+ ultrasonic cleaning. The specimens were storage in distilled water at 37°C for 24 hours and cut into to axes (x and y), then the bar specimens obtained were submitted to 2 conditions (Dry - immediate test; TC - storage + thermocycling) and to the microtensile bond strength test. pH values were significantly high for CS6 compared to that of CS5, CS8 and CS2. CS1 had the highest contact angle. In the microtensile bond strength, CS2=CS1>CS3=CS4, independently from the storage condition. CS4 had the lowest microtensile bond strength value after TC. The neutralization decrease the bond strength significantly, which was evidenced by the high contact angles after the surface neutralization. / Mestre
|
178 |
Cimentação de laminados cerâmicos : efeito de diferentes modos de fotoativação na estabilidade de cor e nas propriedades mecânicas de sistemas adesivos e cimentos resinosos /Sahyon, Henrico Badaoui Strazzi. January 2017 (has links)
Orientador: Paulo Henrique dos Santos / Banca: Wirley Gonçalves Assunção / Banca: Anderson Catelan / Resumo: O objetivo deste estudo in vitro foi avaliar os efeitos de diferentes modos de fotoativação na nanodureza e módulo de elasticidade de sistemas adesivos e cimentos resinosos, assim como o efeito na estabilidade de cor de laminados cerâmicos. Os fatores em estudos foram: dois níveis de fotopolimerizadores (VALO - Ultradent; Radii-Cal - SDI) e três níveis de modo de ativação (sem polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico; polimerização prévia do sistema adesivo somente na superfície dental; e polimerização prévia do sistema adesivo na superfície dental e no interior do laminado cerâmico). Na análise da estabilidade de cor o terceiro fator estudado foi o tempo de envelhecimento (252, 504 e 756 horas). Foram confeccionados 132 blocos de cerâmica (7x8x0,6mm) de dissilicato de lítio (IPS e-max CAD), os quais foram cimentados sobre o esmalte dentário dos dentes bovinos, distribuídos em 12 grupos de acordo com os materiais restauradores e métodos de procedimentos utilizados. Dois sistemas adesivos e cimentos resinosos foram utilizados (Single Bond Universal/RelyX Veneer- 3M/ESPE e Tetric N Bond/Variolink Veneer - Ivoclar Vivadent). As propriedades mecânicas de nanodureza e módulo de elasticidade foram mensuradas utilizando nanodurômetro (Anton Paar), sob ação de carga de 1000μN (n=3). A estabilidade de cor foi mensurada através do espectrofotômetro de reflexão ultravioleta visível UV-2450 (Shimadzu) antes e após a submissão das amo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vitro study was to evaluate the effects of different modes of photoactivation in the nanohardness and elastic modulus of resin cements and adhesives, as well as the effect on the color stability of ceramic laminates. The factors of the studies were: two levels of light curing units (VALO - Ultradent; Radii-Cal - SDI) and three modes of photoactivation (without prior curing of the adhesive system in the tooth surface and inside of the ceramic laminate, prior curing the adhesive system only in the tooth surface, and prior curing of the adhesive system in the tooth surface and within the ceramic laminate). In the analysis of color stability the third factor of the study was the aging time (252, 504 and 756 hours). One hundred and thirty two ceramic blocks (7x8x0.6mm) of lithium dissilicate (IPS e-max CAD) were made, which were cemented on the enamel of bovine teeth, and distributed into 12 groups according to the restorative materials (Single Bond Universal/RelyX Veneer - 3M/ESPE and Excite DSC/Variolink Veneer - Ivoclar Vivadent) and methods of procedures. The mechanical properties of nanohardness and elastic modulus were measured using a nanohardness tester (Anton Paar) under loaf of 1000 μN (n=3). Color stability was measured using a UV-2450 visible UV spectrophotometer (Shimadzu) before and after the submission of the UVB artificial accelerated aging samples (n=8). Data of color stability and mechanical properties were submitted to statistical testes o... (Complete abstract click electronic access below) / Mestre
|
179 |
Nanotubos de nitreto de boro como carga para resinas adesivasDegrazia, Felipe Weidenbach January 2017 (has links)
O objetivo do presente estudo foi desenvolver e avaliar a incorporação de nanotubos de Nitreto de Boro (BNNT) como carga em uma resina adesiva. Foi formulada uma resina adesiva utilizando-se os seguintes reagentes: 2- hidróxietil metacrilato (HEMA), Bisfenol A glicol dimetacrilato (BisGMA), canforoquinona (CQ) e Etil 4-dimetilaminobenzoato (EDAB). Os BNNTs foram caracterizados por Microscopia Eletrônica de Varredura (MEV) e Microscopia Eletrônica de Transmissão (MET). O adesivo experimental com diferentes concentrações de BNNT (0, 0,05, 0,075, 0,1 e 0,15%) foi caracterizado quanto ao ângulo de contato e energia livre de superfície (ELS), dureza e amolecimento em solvente (solução de etanol) em microdurômetro, deposição mineral até 14 dias e grau de conversão por espectroscopia Raman e resistência coesiva. O adesivo experimental com diferentes concentrações de BNNT após imersão por 3 h em 65% HNO3 e 48 h em H2O2 foi caracterizado por grau de conversão e cinética de polimerização por Espectroscopia de infravermelho por transformada de Fourier (FTIR), ângulo de contato em dentina por tensiômetro, citotoxicidade por sulforodamina B (SRB) e resistência de união imediata e longitudinal Os resultados da análise de microscopia eletrônica de varredura e de transmissão demonstraram nanotubos de nitreto de boro com diâmetros de 5 a 10 nanometros com término fechado. Nenhuma modificação no grau de conversão ocorreu após a incorporação de BNNTs até 0,15%. Os ângulos de contato de água e α-bromonaftaleno aumentaram (p < 0,05) e consequentemente a ELS diminuiu após a incorporação de BNNTs ao adesivo. Houve aumento da microdureza e da resistência ao amolecimento em solvente após incorporação de 0,075, 0,1 e 0,15% de BNNTs. Não houve diferença significativa na resistência coesiva entre os diferentes grupos. Foi encontrada deposição mineral nos espécimes com BNNT após sete dias de imersão em SBF (fluido corporal simulado). Após o tratamento dos BNNTs com HNO3 e H2O2 e incorporação ao adesivo, houve aumento do grau de conversão e da taxa de polimerização máxima após incorporação de 0,075 e 0,1% de BNNT. O ângulo de contato à dentina aumentou após a incorporação de 0,15% BNNT. Não houve diferença significativa na resistência de união entre os grupos após 24 h (p >0,05). Após 6 meses a resistência de união diminuiu significativamente para o grupo 0% e 0,15% BNNT. Entretanto, os grupos que tiveram incorporação de BNNT obtiveram maiores valores que 0% (p <0,05). Não houve diferença no crescimento celular (p >0,05) entre os grupos em comparação ao grupo controle positivo (100% de crescimento). A incorporação de BNNT até 0,15% melhorou as propriedades físico-químicas do adesivo dentário, promoveu deposição mineral e aumentou a estabilidade longitudinal sem apresentar citotoxicidade a fibroblastos, fornecendo benefícios consideráveis frente aos materiais disponíveis no mercado. / The aim of this study was to develop and evaluate the incorporation of boron nitride nanotubes (BNNTs) into an adhesive resin. An adhesive resin was developed using the following reagents: 2-hydroxyethyl methacrylate (HEMA), bisphenol-A glycidyl dimethacrylate (BisGMA), camphorquinone (CQ) e ethyl 4- dimethylaminobenzoate (EDAB). BNNTs were characterized by Scanning Electron Microscopy (SEM) and Transmission Electron Microscopy (TEM). The experimental adhesive with different concentrations of BNNT (0, 0.05, 0.075, 0.1 e 0.15%) was characterized by contact angle and surface free energy (SFE), hardness and softening in solvent (ethanol solution) by microdurometer, mineral deposition up to 14 days and degree of conversion by Raman spectroscopy and ultimate tensile strength test. The experimental adhesive with different concentrations of BNNT after immersion for 3 h in 65% HNO3 and 48 h in H2O2 was characterized by degree of conversion and polymerization kinetics by Fourier Transform Infrared Spectroscopy (FTIR), contact angle in dentin by tensiometer, sulforhodamine B (SRB) cytotoxicity and immediate and longitudinal bond strength. The results of scanning and transmission electron microscopy showed boron nitride nanotubes with diameters of 5 to 10 nanometers with closed end tips No change in degree of conversion occurred after the incorporation of BNNTs up to 0.15%. The contact angles of water and α-bromonaphthalene increased (p <0.05) and consequently SFE decreased after the incorporation of BNNTs to adhesive. After incorporation of 0.075, 0.1 and 0.15% BNNTs an increase was shown in microhardness and resistance to softening in solvent. No significant difference in ultimate tensile strength was found among groups. Mineral deposition was found on BNNT specimens after seven days of immersion in SBF (simulated body fluid). After BNNTs´ treatment with HNO3 and H2O2 and incorporation into the adhesive, there was an increase in the degree of conversion and the maximum polymerization rate after incorporation of 0.075 and 0.1% of BNNT. Contact angle in dentin increased after incorporation of 0.15% BNNT. There was no significant difference in microtensile bond strength among groups after 24 h (p> 0.05). After 6 months the bond strength decreased significantly for 0% group and 0.15% BNNT. However, the groups that had BNNT incorporation obtained higher values than 0% (p <0.05). There was no difference in cell growth (p> 0.05) among groups compared to the positive control group (100% growth). The incorporation of BNNT up to 0.15% improved the physicochemical properties of dental adhesive, promoted mineral deposition and increased longitudinal stability with no cytotoxicity to fibroblasts, providing considerable benefits against dental materials available in the market.
|
180 |
Cimentos a base de resina metacrilato associado ao fosfato de cálcio : propriedades biológicasMestieri, Leticia Boldrin January 2017 (has links)
Este trabalho teve como objetivo avaliar as propriedades biológicas de cimentos experimentais a base de resina metacrilato contendo α-tricálcio fosfato (α-TCP) ou hidroxiapatita nanoparticulada (HAp) in vitro e in vivo. Para isto, os cimentos experimentais foram avaliados e comparados com AH Plus (AHP). Na etapa in vitro, os materiais foram mantidos em contato com meio de cultura por 24 horas, coletados e avaliados na concentração de 10%. Células-tronco da papila apical humana (SCAPs) foram submetidas aos ensaios de viabilidade brometo de 3-(4,5-dimetiltiazólio)-2,5-difenil tetrazólio (MTT) e sulfurodamina B (SRB) no período de 24 horas; e a bioatividade foi avaliada pela atividade da enzima fosfatase alcalina (ALP) e deposição de nódulos mineralizados pelo corante vermelho de Alizarina (AR), nos períodos de 1, 5, 10 e 15 dias. Na etapa in vivo, os materiais foram inseridos em tubos de polietileno e colocados no tecido subcutâneo de ratos para avaliação da reação inflamatória, sendo utilizado um tubo vazio como controle e avaliados os períodos de 7, 30 e 90 dias; para avaliação da deposição óssea, os cimentos α-TCP e AHP foram inseridos em cavidades confeccionadas no fêmur de ratos, sendo utilizada uma cavidade vazia como controle e avaliados os períodos de 30 e 90 dias. Para o ensaio de viabilidade e ensaios in vivo, foram utilizados os testes de Kruskal-Wallis e post hoc de Dunn; para avaliação da bioatividade in vitro foram utilizados os testes ANOVA e post hoc de Tukey (P < 0.05). HAp e AHP não apresentaram diferenças estatísticas entre si em ambos os ensaios de citotoxicidade (P> 0,05) e o α-TCP apresentou menor resultado de viabilidade no teste MTT, sendo estatisticamente diferente dos outros (P <0,05). Os ensaios de bioatividade demonstraram aumento na atividade da ALP em todos os grupos (P < 0.05). Observou-se semelhança entre os grupos no primeiro período (P > 0.05), AHP apresentou menores valores em 5 dias (P < 0.05), α-TCP apresentou os maiores valores em 10 dias (P < 0.05), e em 15 dias este cimento foi superior ao AHP (P < 0.05). AR mostrou aumento na quantidade de depósitos mineralizados após 5 dias (P < 0.05). Não houve diferença entre os grupos em 1 dia (P > 0.05), α-TCP, HAp e controle foram semelhantes aos 5 dias (P > 0.05), e em 10 e 15 dias, α-TCP apresentou os maiores valores, sendo diferente dos outros cimentos (P > 0.05). Na avaliação da resposta inflamatória in vivo, observou-se diminuição da inflamação e aumento de fibras colágenas em todos os grupos. Em 7 dias, α-TCP e HAp mostraram resultados semelhantes ao controle CT (P>0.05) e diferentes do AHP (P < 0.05), que foi o único grupo a apresentar células-gigantes neste período. Na avaliação da deposição óssea, houve aumento na deposição de 30 para 90 dias nos grupos α-TCP e controle (P < 0.05), e estes grupos apresentaram resultados semelhantes em 90 dias (P > 0.05), diferindo do AHP (P < 0.05). Conclui-se que a associação de fosfatos de cálcio à resina metacrilato apresentou bons resultados de biocompatibilidade e bioatividade in vitro e in vivo, apresentando potencial para serem utilizados como cimentos obturadores na prática clínica. / This study aimed to evaluate the biological properties of experimental sealers containing α-tricalcium phosphate (α-TCP) or nanoparticulate hydroxyapatite (HAp) in a methacrylate resin-base in vitro and in vivo. For this, the experimental sealers were evaluated and compared with AH Plus (AHP). At the in vitro assays, the materials were kept in contact with culture medium for 24 hours, collected and evaluated at concentrations of 100% and 10%. Stem cells from human apical papilla (SCAPs) were submitted to 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) and sulfurodamine B (SRB) viability assays for 24 hour; and bioactivity was evaluated by alkaline phosphatase enzyme activity (ALP) and deposition of mineralized nodules by Alizarin Red staining (AR), for 1, 5, 10 and 15 days. At in vivo assays, the materials were inserted in polyethylene tubes and placed in subcutaneous tissue of rats to evaluate the inflammatory reaction, using an empty tube as control and evaluating the periods of 7, 30 and 90 days; to evaluate bone deposition, α-TCP and AHP cements were inserted into cavities made in the femur of rats, using an empty cavity as control and evaluating the periods of 30 and 90 days. For viability and in vivo assays, Kruskal-Wallis and Dunn’s post hoc tests were used; for bioactivity, ANOVA and Tukey's post hoc tests were used (P < 0.05). HAp and AHP did not presented statistical differences from each other in both citotoxicity assays (P > 0.05), and α-TCP presented a lower viability result in MTT assay, being statistically different from the other sealers (P < 0.05). The bioactivity assays showed an increase in ALP activity for all groups (P < 0.05). Similar results were found between the groups at the first period (P > 0.05), AHP had the lowest values at 5 days (P < 0.05), α-TCP presented the highest values at 10 days (P < 0.05), and at 15 days, this sealer’s values were higher than AHP (P < 0.05). AR showed an increase in the amount of mineralized deposits after 5 days for all sealers (P < 0.05). No difference between groups were found at 1 day (P > 0.05), α-TCP, HAp and control were similar at 5 days (P > 0.05), and at 10 and 15 days, α-TCP presented the highest values, being different of the other sealers (P > 0.05). Regarding the evaluation of the inflammatory response in vivo, there was a decrease in inflammation and increase of collagen fibers in all groups. At 7 days, α-TCP and HAp showed similar results to the control (P > 0.05) and different from AHP (P < 0.05), which was the only group to present giant cells in this period. In the evaluation of bone deposition, there was an increase in deposition from 30 to 90 days for α-TCP and control groups (P < 0.05), and these groups presented similar results in 90 days (P > 0.05), differing from the AHP (P < 0.05). It was concluded that the association of calcium phosphates and methacrylate resin showed good biocompatibility and bioactivity results in vitro and in vivo, presenting potential to be used as endodontic sealers in clinical practice.
|
Page generated in 0.1157 seconds