• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Desenvolvimento de sonda gama para cirurgia radioguiada

José Oliveira da Silva, Iran 31 January 2008 (has links)
Made available in DSpace on 2014-06-12T23:14:31Z (GMT). No. of bitstreams: 2 arquivo8653_1.pdf: 2473104 bytes, checksum: b0cef593d03225c174859f64a8267ce0 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / O uso de técnicas de cirurgia radioguiada tem crescido e tem se mostrado muito eficiente para as cirurgias de câncer. O procedimento inicia-se antes da cirurgia com a administração ao paciente de um radiotraçador, geralmente emissor gama, que tem grande afinidade pelas células tumorais. Durante a cirurgia, uma sonda detectora de radiação gama é usada para identificar as regiões em que houve maior concentração do material radioativo e, portanto, os locais de células tumorais. Neste trabalho apresentamos os resultados de uma nova sonda detectora de radiação gama que foi desenvolvida visando o seu uso em cirurgias radioguiadas. Esta sonda, chamada de SGHI-01, consiste de um cintilador plástico acoplado a um guia de luz com 60mm de comprimento que é acoplado a uma fotomultiplicadora conectada no sistema eletrônico. Os seguintes testes foram realizados para avaliar o desempenho da sonda SGHI-01: estudo da resposta da sonda para uma fonte pontual em função da distância, espectro de energia para fonte de 241Am e 99mTc, resolução de energia e resolução espacial para a separação de duas fontes de diferentes atividades. A resposta da sonda SGHI-01 foi comparada com a resposta da sonda EUROPROBE que é uma sonda comercial. Os resultados mostraram que a melhor eficiência de detecção é obtida com o detector cintilador plástico com 10mm de comprimento e 7,5mm de diâmetro, revestido com teflon. Os resultados também mostraram que a sonda apresenta uma resposta linear com a atividade da fonte radioativa e que a resolução espacial permite a separação de duas fontes com razão de atividade de 40:1, separadas de 4cm. Os resultados também mostraram que a sonda SGHI-01 apresenta uma resposta similar à sonda EUROPROBE, o que permite concluir que é viável o seu uso nas cirurgias radioguiadas
2

Nuevas aplicaciones de la cirugía radioguiada en los tumores ginecológicos

Paredes Barranco, Pilar 12 February 2007 (has links)
La biopsia selectiva del ganglio centinela ha evolucionado desde los primeros estudios en carcinoma de pene y melanoma hasta su inclusión en las guías clínicas el cáncer de mama y además ha impulsado el desarrollo de la cirugía radioguiada de las lesiones mamarias. Pese a estar bien establecida continua siendo una técnica en constante desarrollo y sus aplicaciones se van ampliando día a día. Esta tesis doctoral, a través de cuatro trabajos de investigación, pretende ampliar las indicaciones de la cirugía radioguiada en el cáncer de mama y tumores ginecológicos. Se valoró el patrón de drenaje extraaxilar en el cáncer de mama en función de la localización del tumor y la vía de administración del trazador. Se observó que el drenaje extraaxilar sólo está presente si se realiza inyección profunda (intratumoral o peritumoral) del trazador, que es más frecuente en cuadrantes internos de la mama. Los ganglios centinela de la cadena mamaria interna fueron positivos en el 15% de los casos, en un caso con ganglio centinela axilar negativo, por lo que cambió la estadificación en 5 pacientes. En un segundo trabajo de investigación se valoró la resección de lesiones mamarias no palpables mediante una gammacámara portátil intraoperatoria que evaluó los márgenes de resección. En la predicción de la indemnidad de los márgenes de resección mostró una congruencia del 60% con la anatomía patológica, siendo mayor para la lesiones de hasta 1 cm (64%). Para la valoración del ganglio centinela en el cáncer de vulva se realizó primero una fase de validación que mostró una tasa de falsos negativos del 0% y un valor predictivo negativo (VPN) del 100%. Durante la fase de aplicación se obtuvo un VPN del 100%. En la valoración de la técnica en el cáncer de cérvix uterino se realizó la biopsia selectiva de ganglio centinela y la linfadenectomía pelviana y eventualmente paraaórtica mediante laparoscopia. Se obtuvo un VPN del 100% y se observó drenaje en territorios no esperados como la cadena ilíaca primitiva.Las conclusiones de este trabajo son: a) es recomendable la resección de los ganglios centinela extraaxilares en el cáncer de mama, ya que mejora la estadificación; b) el uso de una gammacámara intraoperatoria en el cáncer de mama puede predecir la indemnidad de los márgenes, aunque se encuentra en fase de validación; c) la linfogammagrafía combinada con la detección del ganglio centinela mediante radiotrazadores y colorantes disminuye la morbilidad de la cirugía en el cáncer de cérvix y vulva, con un elevado VPN. / Sentinel node biopsy (SNB) has changed since penile carcinoma studies until its inclusion in breast cancer clinical guides or the development of radioguided surgery of breast lesions. SNB is an always-evolving technique, so its indications are increasing each day. This doctoral thesis, by means of four research works, means to increase radioguided surgery indications in breast cancer and gynaecological tumours. Extra-axillary drainage was studied according to the injection site and where the primary tumour was located. Extra-axillary drainage was only seen when deep tracer injection was performed (intratumoral or peritumoral), and it was more frequent when tumour was located in the inner quadrants of the breast.Internal mammary chain sentinel nodes were positive in 15% of the cases, in one case with a negative axillary sentinel node, so it changed the staging in 5 patients. The second research work analysed the resection of occult breast lesions by means of an intraoperative portable gammacamera, that evaluated resection margins. In the prediction of margins indemnity, a congruence of 60% between gammacamera results and pathological examination was obtained, being higher for lesions up to 1 cm (64%). The evaluation of sentinel node in vulvar cancer comprises a validation phase, with a false negative rate of 0% and a negative predictive value (NPV) of 100%. In the application phase, the NPV was of 100%. For the study in cervical cancer, sentinel node biopsy was performed before laparoscopic pelvic ± paraaortic lymphadenectomy and radical hysterectomy. The NPV was 100%. Unexpected drainage was seen in such territories as primitive iliac chain.The conclusions of this work are: a) it is recommended to remove extra-axillary sentinel nodes in breast cancer because it improves staging ; b) the use of an intraoperative gammacamera in breast cancer resection can predict margins indemnity, although it is in validation phase; c) lymphoscintigraphy combined with sentinel node detection by means of radiotracers and blue dyes allows a decrease in surgery morbidity in cervical and vulvar cancer, with an elevated negative predictive value.
3

Cirurgia radioguiada com 99mTc-sestamibi intravenoso e ressonancia nuclear magnetica no cancer de mama / Radioguided surgery with 99mTc-sestamibi intravenous and magnetic resonance imaging for breast cancer

Duarte, Giuliano Mendes 31 October 2007 (has links)
Orientador: Cesar Cabello dos Santos / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-09T08:45:28Z (GMT). No. of bitstreams: 1 Duarte_GiulianoMendes_D.pdf: 5275602 bytes, checksum: 5180518eed1c8045749e430f93e8b706 (MD5) Previous issue date: 2007 / Resumo: Objetivos: Estudar a utilização de cirurgia radioguiada com 99mTc-sestamibi associada à ressonância nuclear magnética (RNM) no câncer de mama. Para isso, foram desenvolvidas duas novas técnicas: uma intitulada Avaliação Intra-peratória Radioguiada das Margens (Radioguided Intraoperative Margins Evaluation -RIME) que usa um radiofármaco intravenoso para auxiliar, através de uma sonda detectora de radiação (probe), a ressecção tumoral; a outra intitulada Fusão da Ressonância Nuclear Magnética e Cintilografia Mamária (Magnetic Resonance Imaging/ Scintimammography fusion ¿ MRI/SM) que procura determinar a extensão tumoral. Dessa forma, esta tese visa avaliar a factibilidade das técnicas, o valor da RIME em obter margens livres e o valor da MRI/SM em determinar o tamanho real do tumor comparando com outros exames. Sujeitos e métodos: Foi realizado um estudo experimental descritivo em 23 mulheres com carcinoma ductal invasivo de mama estádios IIA a IIIA, agendadas para mastectomia. Dois a dez dias antes da cirurgia, as pacientes foram submetidas à cintilografia mamária com 99mTc-sestamibi, na qual foi localizado o tumor e estimado o tempo ideal para iniciar a cirurgia radioguiada através de uma curva de contagem de radiação por tempo. No mesmo dia, 20 pacientes realizaram uma ressonância nuclear agnética com gadolíneo. No momento da cirurgia, a mesma dose de 99mTc-sestamibi foi injetada intravenosamente. Esperou-se o tempo ideal estimado previamente e então foi realizada uma segmentectomia com auxílio do probe, que determinou as margens de ressecção. A ressonância foi usada para avaliar comprometimento da pele, fáscia profunda a outros focos de tumor que foram incluídos na segmentectomia. Isso caracterizou a RIME. Após, todas as pacientes foram submetidas à mastectomia. A egmentectomia e a mama residual foram examinadas histologicamente. Paralelamente, foi desenvolvido um programa de computador em linguagem visual que realizou, de forma semi-automática, a fusão das imagens de ressonância e cintilografia em 20 pacientes (MRI/SM). Foi determinado como tumor na MRI/SM a área de intersecção das imagens, o tumor foi medido e comparado com a medida no exame histológico, ressonância nuclear magnética, mamografia e exame clínico. Para análise estatística foram utilizados os testes exato de Fisher, t de Student, Wilcoxon e regressão linear. Resultados: Em todas as pacientes foi possível realizar as técnicas de RIME e MRI/SM (factibilidade de 100%). A RIME permitiu a ressecção do tumor com margens livres em 19 pacientes, com média de margem de 4,8mm. Em 11 casos não havia doença residual na mama após a segmentectomia. A média do tamanho da doença residual na mama foi 3,6mm e geralmente estava localizado próximo ao leito tumoral (<1,5cm em 10 pacientes). Não houve associação entre presença de doença residual e o tamanho do tumor ou estado das margens. A medida do tumor na MRI/SM teve uma correlação com o exame histológico melhor que a ressonância, a mamografia e exame clínico em todos os diâmetros estudados. Conclusões: As técnicas de RIME e MRI/SM são factíveis. A RIME permitiu auxiliar a ressecção tumoral com margens livres na maioria das vezes. A MRI/SM parece ser melhor que ressonância, mamografia e exame clínico para determinar a extensão tumoral / Abstract: Aims: To study the use of radioguided surgery with 99mTc-sestamibi, associated with magnetic resonance imaging (MRI), for breast cancer evaluation. For this, we developed two techniques: the first was dominated Radioguided Intraoperative Margins Evaluation (RIME), a technique that uses a radiopharmaceutical agent to distinguish normal and cancer tissue with a probe; the second was termed Magnetic Resonance Imaging and Scintimammography fusion (MRI/SM) to determine the extension of cancer. Thus, this study aims to assess the feasibility of techniques, the ability of RIME to obtain free margins and the ability of MRI/SM to determine the real tumor extension, in comparison to other examinations. Subjects and methods: A descriptive experimental study was carried out on 23 women with invasive ductal breast carcinoma, stages IIA to IIIA, programmed for mastectomy. Two to 10 days before the surgery, the patients were submitted to a scintimammography with 99mTc-sestamibi to localize the tumor and to estimate the optimal time to begin radioguided surgery, through a curve of radiation count per time. On the same day, 20 patients realized a MRI with gadolinium. At the moment of the surgery, the same dose of 99mTc-sestamibi was injected intravenously, after a previously-estimated optimal time a segmentectomy was performed with a probe that determined the resection margins. MRI was used to evaluate the compromising of the skin, deep fascia and the other tumor foci that were included in the segmentectomy, characterizing the RIME. All the patients were then submitted to mastectomy. The segmentectomy and residual breast were histopathologically examined. In parallel, software was developed in visual language to perform the MRI/SM fusion in 20 patients. The intersection area between the MRI and scintimammography was determined as tumor in MRI/SM and the tumor was measured and compared with the measurement in the pathological, MRI, mammography and clinical examination. The Fisher¿s exact test, Student¿s t-test, Wilcoxon¿s test and linear regression were used for statistical analysis. Results: The RIME and MRI/SM techniques were successfully performed in all patients (feasibility of 100%). The principal tumor was removed by RIME and provided histologically-free margins in 19 patients (mean margins, 4.8mm). Additionally, 11 patients were without residual disease after segmentectomy. The mean size of residual carcinoma was 3.6mm and generally located near the tumor bed (< 1.5cm in 10 patients). There was no significant association between presence of residual disease and tumor size or margin status. The MRI/SM cancer measurements correlated better with pathology than MRI, mammography and clinical examination in all diameters analyzed. Conclusions: The RIME and MRI/SM techniques are feasible. In general, RIME aids in tumor resection with free margins. MRI/SM seems to be better than MRI, mammography and clinical examination to determine the tumoral extension / Doutorado / Tocoginecologia / Doutor em Tocoginecologia

Page generated in 0.05 seconds