• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 5
  • 4
  • 3
  • 2
  • 2
  • Tagged with
  • 69
  • 69
  • 48
  • 48
  • 43
  • 34
  • 33
  • 28
  • 22
  • 16
  • 15
  • 15
  • 15
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Teleprogramação dos sistemas de implante coclear / Teleprogramming of cochlear implant systems

Samuel, Paola Angelica 16 April 2015 (has links)
Objetivos: Verificar a efetividade da teleprogramação em pacientes usuários de IC comparando os resultados audiológicos do IC e os parâmetros da programação nas condições remota e presencial; verificar a qualidade de transmissão remota e o grau de compreensão das orientações dadas pelo fonoaudiólogo remotamente. Casuística e método: Foi realizado um ensaio clínico randomizado, tipo cross over, no qual a intervenção remota (à distância) foi comparada à presencial. O desfecho do estudo foi a realização da audiometria em campo livre, testes de percepção de fala, além de questionário e escala VAS para análise da satisfação com o atendimento. Os critérios de seleção foram: idade entre 18 e 59 anos, de ambos os gêneros; usuários de IC da marca Cochlear®, unidade interna Nucleus 24® ou Freedom®, com processador de fala Freedom SP®, e tempo de experiência com implante coclear mínima de 12 meses. Os critérios de exclusão foram: dificuldade de compreensão no questionário realizado no início do estudo e deficiência visual que impossibilite a realização da leitura orofacial. Os participantes realizaram duas sessões de programação no mesmo dia: uma presencial - programação presencial (PP) e outra a distância - programação remota (PR). Os mesmos fonoaudiólogos realizaram as duas sessões de programação e a ordem de realização das programações foi randomizada. Foram comparados os níveis mínimos (níveis T) e níveis máximos de estimulação (níveis C) de cinco eletrodos (1, 6, 11, 16, 22). Foram aplicados testes de percepção de fala (frases closed-set, open-set sem ruído e com relação S/R 0 e 10dB, e monossílabos - todos com gravação a 65dB), audiometria em campo livre nas frequências de 250 a 8000Hz, questionário e escala visual analógica (VAS) para satisfação com o atendimento após as programações. Os resultados da audiometria, testes, questionários e do VAS também foram comparados. Resultados: Participaram 20 usuários de IC, com tempo médio de uso do dispositivo de 43 meses. Na comparação entre os níveis T obtidos na PR e PP, houve diferença estatisticamente significante nos eletrodos 22 e 16 (p<0,05), indicando que os níveis foram mais altos na PR. Na comparação entre níveis C, houve diferença estatisticamente significante nos eletrodos 11 e 6 (p < 0,05), indicando que os níveis foram mais altos na PP. Não foram encontradas diferenças estatisticamente significantes entre os testes de percepção de fala e os limiares auditivos obtidos com os mapas da PR e PP (p > 0,05). A escala VAS mostrou diferença estatisticamente significante, sendo o maior valor atribuído à PP (p=0,018). No questionário aplicado, houve diferença estatisticamente significante nas questões referentes à qualidade e comunicação no atendimento, mostrando que a PP apresentou menor dificuldade de compreensão e comunicação. Conclusão: A teleprogramação é viável e eficaz quando comparada à programação presencial. Embora tenham sido encontradas diferenças nos níveis de estimulação entre as programações realizadas de forma remota e presencial, não houve diferença nos resultados dos testes de percepção de fala e audiometria realizadas nos dois procedimentos. A programação presencial possibilitou maior facilidade de comunicação e satisfação em relação ao atendimento, quando comparada à programação realizada de forma remota / Objectives: To verify the effectiveness of teleprogramming in CI users comparing the audiological results of the IC and the programming parameters in remote and live conditions; to verify the quality of remote transmission and the understanding of the guidance given by the audiologists remotely. Patients and methods: We conducted a randomized controlled trial, with crossover, in which the remote intervention (distance) was compared to the live intervention. The end point was the realization of the free field audiometry, speech perception tests, and questionnaire and VAS scale for analysis of satisfaction with the sections. The selection criteria were: age between 18 and 59 years, of both genders; CI users of Cochlear® device, internal unit Nucleus® 24 or Freedom® with speech processor Freedom® SP, and experience with CI of at least 12 months. Exclusion criteria were: difficulty in understanding the questionnaire completed at baseline and visual disability which makes impossible the realization of lip reading. Participants performed two programming sessions on the same day: a live programming (LP) and a remote programming (RP). The same audiologists conducted the two programming sessions and the order of realization of the sessions was randomized. The minimum (T) and maximum (C) stimulation levels of five electrodes (1, 6, 11, 16, 22) were established. Tests were applied for speech perception using 65dBSNR (closed-set sentences, open-set without noise and speech-in-noise with signal-to noise 0dB and 10db, and monosyllables). The patients were also submitted to free field audiometry from 250 to 8000Hz frequencies, visual analog scale (VAS) and questionnaire after the fittings sections. The results were compared using the Wilcoxon Test. Results: The study included a total of 20 CI users, with average time of use of 43 months. Statistically significant difference was found in the T levels for the electrodes 22 and 16 (p < 0.05), which indicates that levels were higher in RP. Statistically significant difference was found in the C levels for the electrodes 11 and 6 (p < 0.05), which indicates that levels were higher in LP. There were no statistically significant differences between the speech perception tests and thresholds obtained with maps of LP and RP (p > 0.05). The VAS scale showed a statistically significant difference, with the highest scores to LP (p = 0.018). In the questionnaire, there was a statistically significant difference in the questions about quality and communication during the sessions, showing that LP allowed less difficulty of understanding and communication. Conclusion: Teleprogramming is feasible and effective when compared to live programming. Although there were some differences in stimulation levels between the remote and live programming sessions, there was no difference in the results of thresholds in audiometry and speech perception tests performed in the two procedures. The live programming allowed better communication and satisfaction when compared to remote programming
12

Caracterização dos potenciais evocados auditivos corticais em indivíduos com longo tempo de uso do implante coclear / Characterization of Cortical Auditory Evoked Potentials in individuals with long-term use of cochlear implants

Lopes, Raquel Caroline Ferreira 28 February 2013 (has links)
As mudanças fisiológicas no sistema auditivo relacionadas à idade refletem nos potenciais evocados auditivos, sendo possível, assim, determinar a relação existente entre estas mudanças e o desenvolvimento das habilidades auditivas comportamentais. A percepção do som pode alterar o eletroencefalograma do humano ouvinte, e estas modificações podem ser extraídas deste registro, identificando os potenciais evocados auditivos, usados para descrever a resposta do sistema auditivo frente à estimulação. O implante coclear tem sido uma opção de sucesso para a reabilitação auditiva de crianças com perda auditiva de grau severo ou profundo; o uso do dispositivo por longo tempo pode alterar as respostas do sistema nervoso auditivo central para a estimulação elétrica por meio do implante coclear, uma vez que a literatura apresenta que a experiência com o implante coclear proporciona melhores resultados quanto à percepção da fala. O objetivo deste estudo foi identificar e verificar as características do componente P1 dos potenciais evocados auditivos corticais em indivíduos com deficiência auditiva com longo tempo de uso do implante coclear e correlacioná-los com o desempenho da percepção da fala e, secundariamente, a outras variáveis relacionadas ao implante coclear. Participaram deste estudo 30 usuários de implante coclear que foram implantados na idade de dois a quatro anos, de ambos os sexos, com tempo de uso do dispositivo eletrônico variando entre seis a 14 anos. Foi pesquisado o componente P1 dos potenciais evocados auditivos corticais com o estímulo de fala /da/ e avaliada a percepção da fala com lista de sentenças. Os procedimentos foram realizados em campo livre. Como resultado, foi constatado que o componente P1 foi registrado em todos os indivíduos avaliados, com valores médios latência em 131,87±34,46 ms e amplitude 2,42±1,46 &#956;V. Notou-se a ocorrência da redução da latência (p=0539) e o aumento da amplitude (p=0,297) do componente P1, com ausência de correlação entre os grupos com menos e mais de 10 anos do uso do dispositivo eletrônico. Ao analisar o desempenho na percepção da fala e as características do componente P1, pela pontuação comportamental, foi considerado como desempenho \"bom\" o escore >54%, e \"ruim\" <=54%, e posterior análise da média de latência do P1 (p=0753) e da amplitude (p=0,399) em ambos os grupos, não foi encontrada diferença estatisticamente significante. Deste modo, a presença do componente P1 em indivíduos usuários de implante coclear demonstra que o implante coclear restaura a capacidade de ouvir. O padrão maturacional do potencial cortical segue o curso semelhante ao da criança ouvinte, porém com um atraso na latência e diminuição da amplitude. Após longo período de uso do implante coclear, o componente P1 não é um preditor único do desempenho na percepção de fala. / The physiological changes in the auditory system based on age reflect in the auditory evoked potentials, thus, it is possible to determine that a relationship exists between these changes and the development of auditory skills. The perception of sound can change the electroencephalogram of the human listener, and these modifications can be extracted from this record, identifying the auditory-evoked potentials used to describe the response of the front auditory system to stimulations. The cochlear implant has been a successful option for hearing correction in children with moderate or serious hearing loss; the long-term use of the device can change the responses of the central nervous auditory system for the electric stimulation through the cochlear implant once the literature shows that the experience with the cochlear implant provides good speech perception results. The objective of this study was to identify and verify the characteristics of the P1 component of the cortical auditory evoked potentials in hearing-impaired individuals with long-term use of the cochlear implant and correlate them with speech development, and secondarily, other variables related to the cochlear implant. Thirty (30) cochlear implant users, both male and female, implanted between the ages of two and four years old and use of the electronic device for the time period between six and 14 years, participated in this study. The P1 component of the cortical auditory evoked potentials was studied with speech stimulation and speech perception evaluated with a list of sentences. The procedures were evaluated in an open environment. As a result, it was found that the P1 component was recorded in each of the evaluated, with average latent values of 31,87±34,46 ms and amplitude of 2,42±1,46 &#956;V. The occurrence of latency reduction (p=0,539) and the increase in amplitude (p=0,297) of the P1 component were noted, with the absence of correlation between the groups with less and more than 10 years of use of the electronic device. When analyzing the effort in speech perception and the characteristics of the P1 component by the behavioral points, the score of >54% was considered \"good\", and <=54% was \"poor\", and the later analysis of the latent values of the P1 component (p=0,753) and the amplitude (p=0,399) in both groups, a statistically significant difference was not found. Thus, the presence of the P1 component in individual cochlear implant users shows that the cochlear implant restores the capacity to hear. The standard maturity potential of the cortical closely follows that of a hearing child, but with a delay in latency and decrease in amplitude. After a long period of cochlear implant use, the P1 component is not a lone predictor of speech perception performance.
13

Caracterização dos potenciais evocados auditivos corticais em indivíduos com longo tempo de uso do implante coclear / Characterization of Cortical Auditory Evoked Potentials in individuals with long-term use of cochlear implants

Raquel Caroline Ferreira Lopes 28 February 2013 (has links)
As mudanças fisiológicas no sistema auditivo relacionadas à idade refletem nos potenciais evocados auditivos, sendo possível, assim, determinar a relação existente entre estas mudanças e o desenvolvimento das habilidades auditivas comportamentais. A percepção do som pode alterar o eletroencefalograma do humano ouvinte, e estas modificações podem ser extraídas deste registro, identificando os potenciais evocados auditivos, usados para descrever a resposta do sistema auditivo frente à estimulação. O implante coclear tem sido uma opção de sucesso para a reabilitação auditiva de crianças com perda auditiva de grau severo ou profundo; o uso do dispositivo por longo tempo pode alterar as respostas do sistema nervoso auditivo central para a estimulação elétrica por meio do implante coclear, uma vez que a literatura apresenta que a experiência com o implante coclear proporciona melhores resultados quanto à percepção da fala. O objetivo deste estudo foi identificar e verificar as características do componente P1 dos potenciais evocados auditivos corticais em indivíduos com deficiência auditiva com longo tempo de uso do implante coclear e correlacioná-los com o desempenho da percepção da fala e, secundariamente, a outras variáveis relacionadas ao implante coclear. Participaram deste estudo 30 usuários de implante coclear que foram implantados na idade de dois a quatro anos, de ambos os sexos, com tempo de uso do dispositivo eletrônico variando entre seis a 14 anos. Foi pesquisado o componente P1 dos potenciais evocados auditivos corticais com o estímulo de fala /da/ e avaliada a percepção da fala com lista de sentenças. Os procedimentos foram realizados em campo livre. Como resultado, foi constatado que o componente P1 foi registrado em todos os indivíduos avaliados, com valores médios latência em 131,87±34,46 ms e amplitude 2,42±1,46 &#956;V. Notou-se a ocorrência da redução da latência (p=0539) e o aumento da amplitude (p=0,297) do componente P1, com ausência de correlação entre os grupos com menos e mais de 10 anos do uso do dispositivo eletrônico. Ao analisar o desempenho na percepção da fala e as características do componente P1, pela pontuação comportamental, foi considerado como desempenho \"bom\" o escore >54%, e \"ruim\" <=54%, e posterior análise da média de latência do P1 (p=0753) e da amplitude (p=0,399) em ambos os grupos, não foi encontrada diferença estatisticamente significante. Deste modo, a presença do componente P1 em indivíduos usuários de implante coclear demonstra que o implante coclear restaura a capacidade de ouvir. O padrão maturacional do potencial cortical segue o curso semelhante ao da criança ouvinte, porém com um atraso na latência e diminuição da amplitude. Após longo período de uso do implante coclear, o componente P1 não é um preditor único do desempenho na percepção de fala. / The physiological changes in the auditory system based on age reflect in the auditory evoked potentials, thus, it is possible to determine that a relationship exists between these changes and the development of auditory skills. The perception of sound can change the electroencephalogram of the human listener, and these modifications can be extracted from this record, identifying the auditory-evoked potentials used to describe the response of the front auditory system to stimulations. The cochlear implant has been a successful option for hearing correction in children with moderate or serious hearing loss; the long-term use of the device can change the responses of the central nervous auditory system for the electric stimulation through the cochlear implant once the literature shows that the experience with the cochlear implant provides good speech perception results. The objective of this study was to identify and verify the characteristics of the P1 component of the cortical auditory evoked potentials in hearing-impaired individuals with long-term use of the cochlear implant and correlate them with speech development, and secondarily, other variables related to the cochlear implant. Thirty (30) cochlear implant users, both male and female, implanted between the ages of two and four years old and use of the electronic device for the time period between six and 14 years, participated in this study. The P1 component of the cortical auditory evoked potentials was studied with speech stimulation and speech perception evaluated with a list of sentences. The procedures were evaluated in an open environment. As a result, it was found that the P1 component was recorded in each of the evaluated, with average latent values of 31,87±34,46 ms and amplitude of 2,42±1,46 &#956;V. The occurrence of latency reduction (p=0,539) and the increase in amplitude (p=0,297) of the P1 component were noted, with the absence of correlation between the groups with less and more than 10 years of use of the electronic device. When analyzing the effort in speech perception and the characteristics of the P1 component by the behavioral points, the score of >54% was considered \"good\", and <=54% was \"poor\", and the later analysis of the latent values of the P1 component (p=0,753) and the amplitude (p=0,399) in both groups, a statistically significant difference was not found. Thus, the presence of the P1 component in individual cochlear implant users shows that the cochlear implant restores the capacity to hear. The standard maturity potential of the cortical closely follows that of a hearing child, but with a delay in latency and decrease in amplitude. After a long period of cochlear implant use, the P1 component is not a lone predictor of speech perception performance.
14

Resolução temporal auditiva de crianças usuárias de implante coclear / Auditory temporal resolution in children using cochlear implantation

Ademir Antonio Comerlatto Junior 15 July 2011 (has links)
A resolução temporal auditiva é considerada uma das habilidades mais importantes para o processamento do sinal acústico ao longo do tempo. Ela permite identificar diferenças finas dos aspectos segmentais da fala, como a identificação de fonemas, e o início e o final de palavras em frases encadeadas. Crianças usuárias de Implante Coclear (IC) apresentam características próprias de decodificação e processamento do sinal da fala ao longo do tempo, realizada pelo IC. Diante do exposto, esta pesquisa teve por objetivo verificar o desempenho de crianças usuárias de IC em tarefas de resolução temporal. A amostra foi composta por 20 crianças usuárias de IC Nucleus 24/SPRINT (Grupo Experimental - GE) e 20 crianças sem alterações auditivas (Grupo Controle - GC). Foram aplicados o Random Gap Detection Test (RGDT) e o teste Gaps In Noise (GIN) para avaliar a habilidade de resolução temporal por meio de tarefas de detecção de gap. Os testes foram aplicados em campo livre e a 40dBNS. Os testes estatísticos utilizados para a análise dos dados foram o teste t de Student para dados independentes, e o teste de Mann Whitney e o Coeficiente de Correlação de Pearson. As crianças usuárias de IC obtiveram limiares de gap no RGDT de 74,13±51 ms e no teste GIN de 12,12±2,53 ms, sendo que apenas quatro das 20 crianças realizaram o teste GIN. Os limiares de gap do GC foram de 18,77±12,29 ms no RGDT e de 6,13±1,27 ms no teste GIN. A diferença entre os dois grupos foi estatisticamente significante. Além disso, houve diferença significativa na comparação dos resultados dos testes entre os sexos do GE, sendo o masculino melhor que o feminino. Não houve correlação entre a idade e os limiares de detecção de gap em ambos os grupos e, também, não houve significância entre o tempo de uso de IC e os resultados nos testes no GE. Mesmo avaliando a mesma habilidade auditiva, não houve correlação significante entre os resultados dos testes aplicados. Foi observado que crianças usuárias de IC apresentam os limiares de detecção de gap significativamente maiores que crianças sem alterações auditivas. / Auditory temporal resolution is considered one of the most important skills for acoustic signal processing along the time. It allows the identification of fine differences of speech segmental aspects, such as phonemes and the beginning and end of words in linked phrases. Children using a cochlear implant (CI) present specific characteristics of speech sign decoding and processing, along the time, performed by the CI. Thus, this research aimed at verifying the performance of children fitted with CIs, in temporal resolution tasks. The sample comprised 20 children using CI Nucleus 24/SPRINT (Experimental group - EG) and 20 children with no auditory alterations (Control Group - CG). The Random Gap Detection (RGDT) and Gaps In Noise (GIN) tests were applied to assess the temporal resolution skill through gap detection tests which were applied in free field and 40 dBSL. The statistical tests utilized for data analysis were Student´s t test, for independent data, Mann Whitney´s test and Pearson´s Correlation Coefficient. The children fitted with CIs achieved gap thresholds of 74,13±51 ms on the RGDT and 12,12±2,53 ms on the GIN test, the latter performed by only four out of the 20 children. Gap thresholds for the CG were 18,77±12,29 ms on the RGDT and 6,13±1,27 ms on the GIN test. The difference between the two groups was statistically significant. There was a significant difference in the comparison of the results of tests between the genders of EG, with males outdoing females. No correlation was seen between age and gap detection thresholds for both groups and there was no significance between the time of CI use and the results on the tests for the EG. Even assessing the same hearing skill, no significant correlation was seen between the results of the tests applied. Thus, it was observed that children fitted with cochlear implantation present gap detection thresholds significantly worse than those presented by normally hearing children.
15

Telemetria de respostas neurais: avaliação do potencial de ação composto do nervo auditivo em crianças / Neural response telemetry: evaluation of the auditory nerve compound action potential in children

Tanamati, Liège Franzini 13 February 2007 (has links)
INTRODUÇÃO: Nos usuários de Implante Coclear (IC), o registro do potencial de ação composto do nervo auditivo evocado eletricamente (ECAP) representa o modo mais efetivo para se avaliar o estado do nervo auditivo em resposta ao estímulo elétrico e a interação entre o eletrodo e o tecido neural. Modificações nas respostas neurais ao longo do tempo têm implicação direta nos mapeamentos das crianças, principalmente durante os primeiros meses de uso do IC. OBJETIVO. Estudar o ECAP em crianças ao longo do primeiro ano de uso do IC. Por meio da Telemetria de Respostas Neurais, as características do ECAP foram analisadas em 13 crianças, implantadas com idades inferiores a três anos de idade. RESULTADOS. Durante o primeiro ano de uso do IC, houve aumento estatisticamente significante para a amplitude do pico N1, nos eletrodos basais, entre o segundo e o terceiro retorno. Não foram obtidas diferenças significantes para a latência do pico N1, para o slope e para o p-NRT, entre os retornos. Discretas alterações foram mais evidentes para os eletrodos basais. A análise entre os eletrodos mostrou que os eletrodos apicais apresentaram maiores amplitudes do N1 e valores do p-NRT, estatisticamente, inferiores aos limiares dos eletrodos apicais. Houve prevalência das respostas com morfologia do tipo Ia para os eletrodos E10, E15 e E20 e do tipo Ic para o eletrodo E5. No primeiro retorno, o tempo de recuperação do nervo auditivo de seu estado refratário foi, para a maioria dos sujeitos, igual a 1000 Mius para o E5, e igual a 2000 Mius para os eletrodos E5, E10 e E15. No terceiro retorno, o tempo de recuperação do E5 aumentou para 2000 Mius e, no E20, diminui para 1000 Mius, para a maioria dos sujeitos. A comparação entre os diferentes modelos revelou que o Implante Coclear N24 R (CS) apresentou as maiores amplitudes, os maiores slopes e as menores latências e menores valores de p-NRT. CONCLUSÃO. Ao longo do primeiro ano de uso do IC, a estimulação elétrica liberada pelos eletrodos intracocleares não causou alterações significativas às características do ECAP, exceto pelo aumento da amplitude do pico N1. / INTRODUCTION: In Cochlear Implant (CI) users, the recording of the electrically evoked compound action potential (ECAP) of the auditory nerve represents the most effective way to assess the auditory nerve in response to electrical stimulus and the interaction between the electrode and the neural tissue. Changes in neural responses, over time, have direct implication in mappings of children, mainly during the first months of CI use. OBJECTIVE: To study ECAP in children during the first year of CI use. Through Telemetry of Neural Responses, the ECAP characteristics have been analyzed in 13 children. The children who were implanted were younger than three years old. RESULTS: During the first year of CI use there was a significant statistical growth for the amplitude of N1 peak, in basal electrodes, between the second and third returns. There were not any significant differences obtained for N1 peak latency, neither for the slope nor for p-NRT, among the returns. The analysis among the electrodes has shown that the apical ones have presented higher N1 amplitudes and p-NRT values, statistically lower than the thresholds of apical electrodes. Responses with Ia type morphology have prevailed for electrodes E10, E15 and E20, and Ic type for electrode E5. In the first return, recovery time of the refractory state of the auditory nerve was in most subjects equals to 1000 Mius for E5, and equals to 2000 Mius for electrodes E5, E10 and E15. In the third return, recovery time of E5 increased to 2000 Mius and in E20 decreased to 1000 Mius, in most subjects. The comparison of the different models has shown that the Cochlear Implant N24 R (CS) has presented the highest amplitudes, the highest slopes and the lowest latencies, and the lowest p-NRT values. CONCLUSION: During the first year of CI use, the electrical stimulation released by intracochlear electrodes did not cause significant changes of ECAP characteristics, except in the increase of N1 peak amplitude.
16

Kineziterapijos poveikis vaikų pusiausvyrai po kochlearinio aparato implantacijos / Influence of kinezetherapy methods for children, to which cochlear implantation is made

Metrikienė, Irma 10 May 2006 (has links)
Relevance After the cochlear implantation 70 per cent of children looses their balance. Number of various kinezitherapheutic exercises are used for developing the balance: exercises on soft, moving surfaces reducing body support area; the ones with „Gymnic�� balls. Music therapy has a modern history, applying it for children with hearing and balance or complex disorder in healing. But classical researches were not made on the issue of what benefit music therapy has on children after cochlear implantation surgery. Dances, games are important for social, emotional, intellectual process of children; it is a natural process optimization mean for preschool children, activity, in context of which, corrective tasks are solved. The object of our research was balance of children, for which cochlear implantation was made. The aim of the research – to deduce an effect of kinezitherapy means to children, to which cochlear implantation was made. Goals: 1. To assess and compare a balance of experimental and control children groups after the cochlear implantation. 2. To assess and compare a balance of experimental and control children groups nine months after the cochlear implantation was made. 3. To evaluate the effect of used kinezetherapy means to children balance. The organization of the research. 32 children whom the cochlear implantation was made took place in the research. They were divided into 2 groups: experimental (n=17) and control (n=15). The research lasted for 9 months. The... [to full text]
17

Comunicação pré-linguística e aquisição de linguagem em crianças com implante coclear / Prelinguistic communication and language aquisition in children with cochlear implants

Fernanda de Lourdes Antonio 21 March 2014 (has links)
Os programas de implante coclear têm recebido crianças com diagnóstico de deficiência auditiva sensorioneural ou com Desordem do Espectro da Neuropatia Auditiva ambos de grau severo e/ou profundo, que não se beneficiam com os aparelhos de amplificação sonora individuais, em idade precoce. Essas crianças são candidatas a realizar a cirurgia de implante coclear ainda nos primeiros anos de vida, período considerado sensível para a plasticidade neuronal. Nesta perspectiva, é um desafio para os profissionais da área determinar precocemente quais crianças podem obter os maiores benefícios com o implante coclear, pois devido a pouca idade, são muito sutis as respostas apresentadas e o comportamento comunicativo ainda incipiente. Este estudo teve como objetivo investigar a correlação entre os comportamentos de comunicação pré-linguística em crianças candidatas à cirurgia de implante coclear e a aquisição da linguagem falada subsequente ao uso do dispositivo. Participaram 11 crianças com deficiência auditiva sensorioneural severo e/ou profundo bilateral pré-lingual e duas crianças com Desordem do Espectro da Neuropatia Auditiva bilateral de grau severo e/ou profundo. O estudo de caráter longitudinal prospectivo avaliou os participantes da pesquisa em quatro tempos distintos, sendo o primeiro tempo no momento pré-cirúrgico e os demais tempos após a ativação do implante coclear, ao longo do primeiro ano de uso do dispositivo. Os dados foram coletados em entrevistas com os pais dos participantes da pesquisa, análise dos registros dos prontuários e avaliação da comunicação pré-linguística e de linguagem falada de cada criança. Foram utilizados os instrumentos: Denver Developmental Screening Test II DDST II, MacArthur - Bates Communicative Development Inventory (CDI) Parte II Ações e Gestos, Escala de Compreensão e Expressão Reynell Developmental Language Scales RDLS e a Escala de avaliação de desenvolvimento familiar. Os instrumentos utilizados para avaliar as habilidades comunicativas e de linguagem falada guardaram correlação positiva entre eles. O grupo estudado apresentou evolução no comportamento pré-linguístico e na aquisição da linguagem falada ao longo do uso do implante coclear. Houve correlação positiva entre a comunicação pré-linguística e a aquisição da linguagem falada das crianças participantes do estudo. / The cochlear implants programs have received early age children diagnosed with bilateral prelingual severe-to-profound sensorineural hearing loss or bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder, who didnt benefit from hearing aids. These children are candidates for cochlear implant surgery still in the early years of life, period considered sensitive for neuronal plasticity In this perspective, it is a challenge for professionals is to determine precociously which children can get the greatest benefits with the cochlear implant, because due to their young age, the answers provided are very subtle and the communicative behavior still very incipient. The purpose of this study was to investigate the relationship between prelinguistic communication behaviors in implantation candidates and subsequent language development after cochlear implant use. The study included 11 bilateral prelingual severe-to-profound sensorineural hearing loss children and two children with bilateral prelingual severe-to-profound Auditory Neuropathy Spectrum Disorder. The prospective longitudinal study assessed the children in preimplantation period and during the first year of use after cochlear implant activation, totaling four assessments for each participant. Datas were collected through interviews with the participants parents, analysis of medical records and assessment evaluation of prelinguistic communication and spoken language of each child. Denver Developmental Screening Test II DDST II, MacArthur-Bates Communicative Development Inventory - CDI, Reynell Developmental Language Scales RDLS and Family Involvement Pating were used. There was a positive correlations between instruments used to assess the prelinguistic communication behaviors and spoken language. The group investigated showed an increase in prelinguistic behavior and the acquisition of spoken language throughout the cochlear implant use. There was a positive correlation between prelinguistic communication and the acquisition of spoken language of the participating children in the study.
18

Telemetria de respostas neurais: avaliação do potencial de ação composto do nervo auditivo em crianças / Neural response telemetry: evaluation of the auditory nerve compound action potential in children

Liège Franzini Tanamati 13 February 2007 (has links)
INTRODUÇÃO: Nos usuários de Implante Coclear (IC), o registro do potencial de ação composto do nervo auditivo evocado eletricamente (ECAP) representa o modo mais efetivo para se avaliar o estado do nervo auditivo em resposta ao estímulo elétrico e a interação entre o eletrodo e o tecido neural. Modificações nas respostas neurais ao longo do tempo têm implicação direta nos mapeamentos das crianças, principalmente durante os primeiros meses de uso do IC. OBJETIVO. Estudar o ECAP em crianças ao longo do primeiro ano de uso do IC. Por meio da Telemetria de Respostas Neurais, as características do ECAP foram analisadas em 13 crianças, implantadas com idades inferiores a três anos de idade. RESULTADOS. Durante o primeiro ano de uso do IC, houve aumento estatisticamente significante para a amplitude do pico N1, nos eletrodos basais, entre o segundo e o terceiro retorno. Não foram obtidas diferenças significantes para a latência do pico N1, para o slope e para o p-NRT, entre os retornos. Discretas alterações foram mais evidentes para os eletrodos basais. A análise entre os eletrodos mostrou que os eletrodos apicais apresentaram maiores amplitudes do N1 e valores do p-NRT, estatisticamente, inferiores aos limiares dos eletrodos apicais. Houve prevalência das respostas com morfologia do tipo Ia para os eletrodos E10, E15 e E20 e do tipo Ic para o eletrodo E5. No primeiro retorno, o tempo de recuperação do nervo auditivo de seu estado refratário foi, para a maioria dos sujeitos, igual a 1000 Mius para o E5, e igual a 2000 Mius para os eletrodos E5, E10 e E15. No terceiro retorno, o tempo de recuperação do E5 aumentou para 2000 Mius e, no E20, diminui para 1000 Mius, para a maioria dos sujeitos. A comparação entre os diferentes modelos revelou que o Implante Coclear N24 R (CS) apresentou as maiores amplitudes, os maiores slopes e as menores latências e menores valores de p-NRT. CONCLUSÃO. Ao longo do primeiro ano de uso do IC, a estimulação elétrica liberada pelos eletrodos intracocleares não causou alterações significativas às características do ECAP, exceto pelo aumento da amplitude do pico N1. / INTRODUCTION: In Cochlear Implant (CI) users, the recording of the electrically evoked compound action potential (ECAP) of the auditory nerve represents the most effective way to assess the auditory nerve in response to electrical stimulus and the interaction between the electrode and the neural tissue. Changes in neural responses, over time, have direct implication in mappings of children, mainly during the first months of CI use. OBJECTIVE: To study ECAP in children during the first year of CI use. Through Telemetry of Neural Responses, the ECAP characteristics have been analyzed in 13 children. The children who were implanted were younger than three years old. RESULTS: During the first year of CI use there was a significant statistical growth for the amplitude of N1 peak, in basal electrodes, between the second and third returns. There were not any significant differences obtained for N1 peak latency, neither for the slope nor for p-NRT, among the returns. The analysis among the electrodes has shown that the apical ones have presented higher N1 amplitudes and p-NRT values, statistically lower than the thresholds of apical electrodes. Responses with Ia type morphology have prevailed for electrodes E10, E15 and E20, and Ic type for electrode E5. In the first return, recovery time of the refractory state of the auditory nerve was in most subjects equals to 1000 Mius for E5, and equals to 2000 Mius for electrodes E5, E10 and E15. In the third return, recovery time of E5 increased to 2000 Mius and in E20 decreased to 1000 Mius, in most subjects. The comparison of the different models has shown that the Cochlear Implant N24 R (CS) has presented the highest amplitudes, the highest slopes and the lowest latencies, and the lowest p-NRT values. CONCLUSION: During the first year of CI use, the electrical stimulation released by intracochlear electrodes did not cause significant changes of ECAP characteristics, except in the increase of N1 peak amplitude.
19

Teleprogramação dos sistemas de implante coclear / Teleprogramming of cochlear implant systems

Paola Angelica Samuel 16 April 2015 (has links)
Objetivos: Verificar a efetividade da teleprogramação em pacientes usuários de IC comparando os resultados audiológicos do IC e os parâmetros da programação nas condições remota e presencial; verificar a qualidade de transmissão remota e o grau de compreensão das orientações dadas pelo fonoaudiólogo remotamente. Casuística e método: Foi realizado um ensaio clínico randomizado, tipo cross over, no qual a intervenção remota (à distância) foi comparada à presencial. O desfecho do estudo foi a realização da audiometria em campo livre, testes de percepção de fala, além de questionário e escala VAS para análise da satisfação com o atendimento. Os critérios de seleção foram: idade entre 18 e 59 anos, de ambos os gêneros; usuários de IC da marca Cochlear®, unidade interna Nucleus 24® ou Freedom®, com processador de fala Freedom SP®, e tempo de experiência com implante coclear mínima de 12 meses. Os critérios de exclusão foram: dificuldade de compreensão no questionário realizado no início do estudo e deficiência visual que impossibilite a realização da leitura orofacial. Os participantes realizaram duas sessões de programação no mesmo dia: uma presencial - programação presencial (PP) e outra a distância - programação remota (PR). Os mesmos fonoaudiólogos realizaram as duas sessões de programação e a ordem de realização das programações foi randomizada. Foram comparados os níveis mínimos (níveis T) e níveis máximos de estimulação (níveis C) de cinco eletrodos (1, 6, 11, 16, 22). Foram aplicados testes de percepção de fala (frases closed-set, open-set sem ruído e com relação S/R 0 e 10dB, e monossílabos - todos com gravação a 65dB), audiometria em campo livre nas frequências de 250 a 8000Hz, questionário e escala visual analógica (VAS) para satisfação com o atendimento após as programações. Os resultados da audiometria, testes, questionários e do VAS também foram comparados. Resultados: Participaram 20 usuários de IC, com tempo médio de uso do dispositivo de 43 meses. Na comparação entre os níveis T obtidos na PR e PP, houve diferença estatisticamente significante nos eletrodos 22 e 16 (p<0,05), indicando que os níveis foram mais altos na PR. Na comparação entre níveis C, houve diferença estatisticamente significante nos eletrodos 11 e 6 (p < 0,05), indicando que os níveis foram mais altos na PP. Não foram encontradas diferenças estatisticamente significantes entre os testes de percepção de fala e os limiares auditivos obtidos com os mapas da PR e PP (p > 0,05). A escala VAS mostrou diferença estatisticamente significante, sendo o maior valor atribuído à PP (p=0,018). No questionário aplicado, houve diferença estatisticamente significante nas questões referentes à qualidade e comunicação no atendimento, mostrando que a PP apresentou menor dificuldade de compreensão e comunicação. Conclusão: A teleprogramação é viável e eficaz quando comparada à programação presencial. Embora tenham sido encontradas diferenças nos níveis de estimulação entre as programações realizadas de forma remota e presencial, não houve diferença nos resultados dos testes de percepção de fala e audiometria realizadas nos dois procedimentos. A programação presencial possibilitou maior facilidade de comunicação e satisfação em relação ao atendimento, quando comparada à programação realizada de forma remota / Objectives: To verify the effectiveness of teleprogramming in CI users comparing the audiological results of the IC and the programming parameters in remote and live conditions; to verify the quality of remote transmission and the understanding of the guidance given by the audiologists remotely. Patients and methods: We conducted a randomized controlled trial, with crossover, in which the remote intervention (distance) was compared to the live intervention. The end point was the realization of the free field audiometry, speech perception tests, and questionnaire and VAS scale for analysis of satisfaction with the sections. The selection criteria were: age between 18 and 59 years, of both genders; CI users of Cochlear® device, internal unit Nucleus® 24 or Freedom® with speech processor Freedom® SP, and experience with CI of at least 12 months. Exclusion criteria were: difficulty in understanding the questionnaire completed at baseline and visual disability which makes impossible the realization of lip reading. Participants performed two programming sessions on the same day: a live programming (LP) and a remote programming (RP). The same audiologists conducted the two programming sessions and the order of realization of the sessions was randomized. The minimum (T) and maximum (C) stimulation levels of five electrodes (1, 6, 11, 16, 22) were established. Tests were applied for speech perception using 65dBSNR (closed-set sentences, open-set without noise and speech-in-noise with signal-to noise 0dB and 10db, and monosyllables). The patients were also submitted to free field audiometry from 250 to 8000Hz frequencies, visual analog scale (VAS) and questionnaire after the fittings sections. The results were compared using the Wilcoxon Test. Results: The study included a total of 20 CI users, with average time of use of 43 months. Statistically significant difference was found in the T levels for the electrodes 22 and 16 (p < 0.05), which indicates that levels were higher in RP. Statistically significant difference was found in the C levels for the electrodes 11 and 6 (p < 0.05), which indicates that levels were higher in LP. There were no statistically significant differences between the speech perception tests and thresholds obtained with maps of LP and RP (p > 0.05). The VAS scale showed a statistically significant difference, with the highest scores to LP (p = 0.018). In the questionnaire, there was a statistically significant difference in the questions about quality and communication during the sessions, showing that LP allowed less difficulty of understanding and communication. Conclusion: Teleprogramming is feasible and effective when compared to live programming. Although there were some differences in stimulation levels between the remote and live programming sessions, there was no difference in the results of thresholds in audiometry and speech perception tests performed in the two procedures. The live programming allowed better communication and satisfaction when compared to remote programming
20

Telemetria de resposta neural: repercussões dos fatores etiológicos e no reconhecimento de fala após o implante coclear / Neural response telemetry: repercussions of etiological factors and speech recognition after cochlear implant

Mariana Cardoso Guedes 04 December 2007 (has links)
INTRODUÇÃO: O Potencial de Ação Composto Evocado Eletricamente(PACEE) é a medida da atividade sincrônica das fibras neurais eliciadas pelo implante coclear. O potencial é registrado diretamente da cóclea, utilizando os eletrodos como geradores do estímulo e gravadores da resposta, procedimento denominado Telemetria de Resposta Neural (TRN). A análise das características da resposta neural pode ser útil no conhecimento sobre a funcionalidade do nervo auditivo e das estruturas neurais sobreviventes. A presença do PACEE pode estar, portanto, relacionada ao resíduo auditivo e influenciar no desempenho para processar os estímulos de fala. OBJETIVO: Identificar os possíveis fatores associados à ausência do PACEE na condição intra-operatória e avaliar a repercussão da ausência de resposta neural no desempenho em testes de reconhecimento de fala após 06 meses de uso contínuo do implante coclear. MÉTODOS: Clínico longitudinal retrospectivo. Participaram do estudo todos os indivíduos operados entre 2003 e 2006 com o implante N24 e cujos exames evidenciaram inserção completa e ausência de alterações nas impedâncias (n = 97). A ausência da resposta neural foi estabelecida quando não se encontrava registro de onda com reprodutibilidade em nenhuma das séries de otimização em todos os eletrodos pesquisados. Os processadores de fala foram ativados com parâmetros sugeridos pelo fabricante e os níveis de corrente determinados pelo método psicoacústico. Os testes de percepção de fala foram realizados após seis meses de uso contínuo e sem leitura orofacial ou apoio de gestos. Os indivíduos foram divididos em grupos de acordo com a presença do PACEE: Grupo \"TRN presente\" e Grupo \"TRN ausente\". A média dos resultados nos testes de reconhecimento de fala foi comparada entre os dois grupos utilizandose o teste não paramétrico U de Mann-Whitney, Teste exato de Fisher e teste do Quiquadrado. RESULTADOS: No Grupo TNR ausente a prevalência de surdez por meningite foi de 48% e no Grupo TNR presente de 13.9% (p < 0,001). O risco relativo para um indivíduo com surdez pós-meningite não apresentar respostas neurais para o estímulo elétrico no intra-operatório é 3.1 vezes maior do que o de um indivíduo com surdez por outras causas. A amostra foi estratificada por etiologia. Os resultados mostraram forte associação entre a ausência do PACEE e piores resultados em testes de reconhecimento de fala. OS resultadoS dos indivíduos em que o potencial foi ausente foram significantemente menor que a média dos indivíduos com PACEE presente (p = 0,002), independente da etiologia da surdez. CONCLUSÃO: A ausência do PACEE em usuários do implante coclear sugere pobre capacidade de despolarização e de condução neural diante da estimulação elétrica. A etiologia de surdez por meningite esteve associada à ausência do potencial e à piores resultados nos testes de reconhecimento de fala. Independentemente deste fator, a presença do potencial no momento intra-operatório esteve associada ao melhor desempenho para processar estímulos de fala, sugerindo um bom prognóstico com o dispositivo. / INTRODUCTION: The Electrically Evoked Compound Action Potential (ECAP) is the register of synchronic activity o neural fibers stimulated by Cochlear Implant. The potential is registered directly from the cochlea using the electrodes as stimulus probe and recorder. This procedure is called Neural Response Telemetry (NRT). The analysis of ECAP can be useful to understand the auditory system function and the surviving neural population. The ECAP presence could be, though, related to auditory residual and influence the ability to process the speech stimulus. Objective: to identify the factors associated to the absent NRT responses and the consequence repercussions for speech recognition after six months of cochlear implant use. METHODS: longitudinal retrospective clinical study. Selection criteria: individual who received N24 cochlear implant model between 2003 and 2006 and presented exams showing complete insertion of electrode array and normal impedances results (n = 97). The NRT absent responses were established when there was no reproducible register in any optimization series of all electrodes searched. The implant speech processors were mapped according to the manufactures default. The current levels were determined by psychoacoustic method. The speech perception battery tests were performed after six months of continual use of device, without lipreading or gestures. The individuals were divided in two groups: Group \"NRT present\" and Group \"NRT absent\". The average of speech perception tests results were compared between groups using the non-parametric Mann-Whitney U test, Exact Fisher\'s test and Chi-square test. RESULTS: In NRT absent group the prevalence of post meningitis hearing loss was 48% and in NRT present group of 13.9% (p < 0.001). The results showed strong association between the absence of ECAP and lower performance in speech recognition sentence test. In these results, the average of subjects whose potential were absent was significantly lower than the ones with ECAP present by intraoperative NRT, regardless the hearing loss etiology (p = 0.002). CONCLUSION: The ECAP absence in cochlear implant users suggests poor neural conduction under electrical stimulus. The post meningitis hearing loss was associated to the absence of potential and poor performance in the speech recognition tests. However, the presence of reproducible ECAP waves was associated to a better performance in processing speech stimulus and suggests a good prognosis with the cochlear implant device.

Page generated in 0.5284 seconds