• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Espectrômetro de elétrons para medidas de coeficientes de conversão interna

Suita, Julio Cezar, Instituto de Engenharia Nuclear 07 1900 (has links)
Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2017-09-27T17:16:35Z No. of bitstreams: 1 JULIO CEZAR SUITA M.pdf: 2924590 bytes, checksum: 3ca6a9332bf5826ee588b62312ae0320 (MD5) / Made available in DSpace on 2017-09-27T17:16:35Z (GMT). No. of bitstreams: 1 JULIO CEZAR SUITA M.pdf: 2924590 bytes, checksum: 3ca6a9332bf5826ee588b62312ae0320 (MD5) Previous issue date: 1982-07 / Foram feitas a recuperação e modificações num espectrômetro de elétrons do tipo solenoidal equipado com um detector semicondutor de Si(Li), que tornaram possível a sua utilização em medidas de coeficientes de conversão interna de transições provenientes do decaimento de nuclídeos de meia-vida de até um segundo. Após estas modificações, mediram-se os coeficientes de conversão interna das transições de 148 KeV e 329 KeV do decaimento do 92 TC, e de 263 KeV e 391 KeV do decaimento do 93m Mo e 9 3 m Tc respectivamente. / Improvements were made on a solenoidal electron spectrometer equiped with a Si(Li) semiconductor detector, in order to use it in internal conversion coefficients measurements of transitions following the decay of nuclides with half-life as short as one second or even lower. After such improvements, the internal conversion coefficients of the transitions of 148 KeV and 329 KeV in the decay of 92 Tc, and 263 KeV and 391 KeV in the decay of 93m Mo and 93m Tc respectively, were measured
2

Simulação Monte Carlo de cenários de radiologia intervencionista pediátrica no código MCNPX

Cavalcante, Fernanda Rocha 21 February 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Interventional radiology consists of minimally invasive procedures guided by real-time X-ray imaging of a region of the patient to be diagnosed or treated. Since it is a practice that uses ionizing radiation, performing these procedures should follow the three basic principles of radioprotection, which are justification, optimization (medical exposure), and dose limitation (occupational exposure). Interventional procedures in children with congenital heart defects are justified by substituting other high-risk procedures. However, as these procedures are responsible for high doses in the patient and individuals occupationally exposed (IOE), it is important to evaluate the medical exposures of pediatric individuals due to a greater susceptibility to radiation damage in these individuals who present a rapid metabolism and closer proximity of the organs. In addition, the longer life expectancy in children allows more time for any harmful effects of radiation, such as cancer, to manifest. Because direct dose measurement within the human body is difficult or impractical, the Monte Carlo simulation of radiation transport is a useful tool in estimating dosimetric protection quantities (H T and E) in anthropomorphic phantoms representing the anatomy of the human body. In addition, it is possible to calculate conversion coefficients that relate protection quantities with measurable quantities, such as the kerma-area product (PKA). In this work, we modelled paediatric interventional cardiology scenarios using the MCNPX code and a pair of adult and paediatric hybrid anthropomorphic phantoms (newborn, 1 year and 5 year) to evaluate medical and occupational exposures. The results obtained in this work show conversion coefficients H T /PKA and E/PKA of 5 to 16 times higher than the values obtained in the literature for interventional procedures performed in adult patients. In addition, we estimate the influence of personal protective equipment (lead apron, thyroid shield and lead glasses) on occupational exposures, which contribute to reduction of H T doses in the physician up to 98% (gonads and thyroid), when used. / A radiologia intervencionista consiste de procedimentos minimamente invasivos guiados por imagens de raios X em tempo real de uma região do paciente a ser diagnosticada ou tratada. Por ser uma prática que utiliza radiação ionizante, a realização destes procedimentos deve seguir os três princípios básicos de radioproteção, que são a justificação, otimização (exposição do paciente) e limitação de dose (exposição do médico). Os procedimentos intervencionistas em crianças com cardiopatias congênitas são justificáveis por substituírem outros procedimentos de alto risco. Entretanto, conforme estes procedimentos são responsáveis por altas doses no paciente, além dos indivíduos ocupacionalmente expostos (IOE), é importante avaliar as exposições médicas de indivíduos pediátricos devido uma maior susceptibilidade de ocorrência de danos provocados pela radiação nestes indivíduos, que apresentam metabolismo rápido e maior proximidade anatômica dos órgãos. Além disso, a maior expectativa de vida das crianças induz uma maior probabilidade de ocorrência de efeitos estocásticos tardios como o câncer. Devido à medição direta da dose dentro do corpo humano ser difícil ou impraticável, a simulação Monte Carlo do transporte de radiação é uma ferramenta útil na estimativa de grandezas dosimétricas de proteção (H T e E) em simuladores antropomórficos que representam a anatomia do corpo humano. Além disso, é possível calcular coeficientes de conversão que relacionam grandezas de proteção com grandezas mensuráveis, como o produto kerma-área (PKA). Neste trabalho, modelamos cenários de cardiologia intervencionista pediátrica utilizando o código MCNPX e uma dupla de simuladores antropomórficos híbridos adulto e pediátrico (recém-nascido, de 1 e 5 anos) para avaliar as exposições médicas e ocupacionais. Os resultados obtidos neste trabalho mostram coeficientes de conversão H T /PKA e E/PKA de 5 a 16 vezes maiores que os valores obtidos na literatura para procedimentos intervencionistas realizados em pacientes adultos. Além disso, estimamos a influência dos equipamentos de proteção individual (avental, óculos plumbíferos e protetor de tireoide) nas exposições ocupacionais, que contribuem para redução das doses H T no médico em até 98% (gônadas e tireoide), quando utilizados.
3

Modificação das posturas dos simuladores antropomórficos voxel de referência Adult Male (AM) e Adult Female (AF) para cálculo de coeficientes de conversão de dose / Posture modification of the reference anthropomorphic voxel phantom Adult Male (AM) and Adult Female (AF) for dose conversion coefficients calculation

Galeano, Diego Castanon 11 October 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Establish limits to the exposure of the population to various ionizing radiation sources is crucial to prevent occupationally exposed individuals and the public, to their deleterious effects. In computational ambit, it is necessary that different exposure scenarios are simulated in order to obtain the dose coefficients (CCs), which relate physical dosimetric quantities - as absorbed dose, Fluency or Kerma Air - with limiting quantities - as equivalent and / or effective dose. Under certain exposure conditions, the individual's posture is not always the same, and the scenario shall be described as realistic as possible. In this work, the AM (Adult Male) and AF (Adult Female) anthropomorphic reference phantom of ICRP publication n° 110 had their postures modified from supine posture (standing) to sitting posture. The change of posture was performed through of a subroutine written in the Visual Monte Carlo code (VMC) to rotate the thigh region of the phantom and position it between the region of the leg and torso. The ScionImage software was used to reconstruct and smooth the knee and hip contours in a sitting posture phantom, and for 3D visualization of phantom was used VolView software. After this step the MCNPX radiation transport code was used for the calculation of fluence-to-dose conversion coefficients (CCs) to six irradiation geometries: AP, PA, LLAT, RLAT, ROT and ISO, recommended by ICRP. The results were compared between the phantoms in standing and sitting postures, for both sexes, in order to assess differences in scattering and absorption of radiation in different postures. The results show significant differences of up to 100% in the equivalent dose conversion coefficients of organs in the pelvic region, 79 % in organs with distribution in the whole body (such as skin, muscle, lymph nodes, bone marrow and trabecular bone) and a difference of 27% to effective dose conversion coefficients. Moreover in order to conduct a comparative study between two types of simulators, was estimated CCs equivalent and effective dose of adult male hybrid simulators, UFHADM, and female, UFHADF, in a sitting posture, and compared to the AM and AF simulators, also in the sitting posture, where it was observed significant difference in energies below 0.05 MeV. This study demonstrated the feasibility of using anthropomorphic phantoms in the sitting posture to represent more realistic postures and can be used in studies in medical and occupational dosimetry. This study demonstrated the feasibility of using anthropomorphic simulators reference in the seated position to represent more realistic positions can thus be used in studies in medical and occupational dosimetry as well as the importance of developing as realistic simulators as possible to dose estimation as faithful as possible in different irradiation scenarios. / Estabelecer limites à exposição da população a diversas fontes de radiação ionizante é de fundamental importância para prevenir indivíduos, ocupacionalmente expostos e do público, dos seus efeitos deletérios. Em âmbito computacional, é necessário que diferentes cenários de exposição sejam simulados, visando à obtenção dos coeficientes de dose (CCs), que associam grandezas dosimétricas físicas – como dose absorvida, fluência ou kerma no ar – com grandezas limitantes – como equivalente e/ou dose efetiva. Em certas condições de exposição a posição do indivíduo nem sempre é a mesma, e o cenário deve ser descrito da forma mais realística possível. Neste trabalho, os simuladores antropomórficos de referência da publicação nº 110 da ICRP, AM (Adult Male) e AF (Adult Female), tiveram suas posturas modificadas da postura supinada (em pé) para a postura sentada. A mudança de postura foi realizada por meio de uma subrotina escrita no software Visual Monte Carlo (VMC) para rotacionar a região da coxa dos simuladores e posicioná-la entre a região da perna e do tronco. O software ScionImage foi utilizado para reconstruir e suavizar os contornos no joelho e quadril dos simuladores na postura sentada, e com ferramenta auxiliar para visualização 3D dos simuladores foi utilizado o software VolView. Após essa etapa foi utilizado o código de transporte de radiação MCNPX para o cálculo dos coeficientes de conversão (CCs) de dose equivalente e efetiva por fluência de partículas, calculados para seis geometrias de irradiação AP, PA, LLAT, RLAT, ROT e ISO, recomendadas pela ICRP. Os resultados foram comparados entre os simuladores em pé e sentado, para ambos os gêneros, com o objetivo de avaliar as diferenças de espalhamento e absorção da radiação para as diferentes posturas. Os resultados dos CCs mostram diferenças significativas, de até 100 % para dose equivalente dos órgãos situados a região pélvica e 79 % em órgãos com distribuição em todo o corpo como, por exemplo, pele, músculo, nódulos linfáticos medula óssea e trabécula óssea, e uma diferença de 14 % para dose efetiva. Ademais, a fim de realizar um estudo comparativo entre dois tipos de simuladores, foi estimado os CCs de dose equivalente e efetiva dos simuladores híbridos adulto masculino, UFHADM, e feminino, UFHADF, na postura sentada, e comparado com os simuladores AM e AF, também na postura sentada, onde foi observado diferença significativa em energias abaixo de 0,05 MeV. Este estudo demonstrou a viabilidade do uso dos simuladores antropomórficos de referência na postura sentada para representar posturas mais realísticas podendo assim, ser utilizado em estudos na dosimetria médica e ocupacional, bem como a importância de desenvolver simuladores tão realista quanto possíveis para estimativa de dose tão fiéis quanto possíveis em diversos cenários de irradiação.

Page generated in 0.1068 seconds