• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Dosimetria e aspectos de proteção radiológica em exames radiográficos convencionais pediátricos realizados em Belo Horizonte

LACERDA, Marco Aurélio de Sousa January 2007 (has links)
Made available in DSpace on 2014-06-12T23:15:51Z (GMT). No. of bitstreams: 2 arquivo9138_1.pdf: 3629377 bytes, checksum: 18a97e614b1455caec99a00145c4b31c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2007 / No presente trabalho foi realizado um levantamento das condições de radioproteção e das doses recebidas pelos pacientes pediátricos em exames radiográficos convencionais realizados em instituições da cidade de Belo Horizonte, MG. Quatro hospitais com alta demanda de exames de radiodiagnóstico pediátrico foram selecionados para a realização do trabalho. Foram acompanhados os exames de tórax e seios da face em 942 pacientes, que resultaram em 1536 procedimentos radiográficos. Inicialmente, foram efetuadas as avaliações das instalações radiológicas dos hospitais selecionados, que envolveram os testes de desempenho dos equipamentos, bem como a avaliação das condições de radioproteção. A partir dos valores dos rendimentos dos tubos de raios X e dos parâmetros das técnicas radiográficas empregados nos exames foram estimados os valores de Kerma no ar na superfície de entrada (Ka,e) e do Produto Kerma no ar-área (PK,A). As doses nos órgãos mais expostos e dose efetiva foram estimadas com o software PCXMC®, a partir dos dados antropométricos, parâmetros de irradiação e do Kerma no ar incidente (Ka,i). Foi constatado que os parâmetros de irradiação empregados nos exames de tórax e seios da face não estão de acordo com os dois principais guias de boas práticas em radiologia pediátrica. O emprego de tensões baixas e tempos de exposição / cargas altas são comuns em todos os hospitais. Os altos valores de carga empregados estão normalmente associados aos baixos rendimentos dos aparelhos, uso desnecessário de grades anti-espalhamento e restrições dos temporizadores dos equipamentos de raios X que não são apropriados para a realização de exames em pacientes pediátricos. Cerca de 75% dos exames de tórax incidências antero-posterior (AP) e postero-anterior (PA) em pacientes entre 1 e 5 anos de idade forneceram valores de Ka,e inferiores a 100 μGy. Para pacientes com idades entre 5 e 10 anos, esse percentual foi de aproximadamente 55%. No caso dos exames de tórax incidência lateral (LAT), cerca de 70% dos exames realizados em pacientes com idades entre 5 e 10 anos forneceram valores de Ka,e inferiores a 200 μGy. No caso de pacientes com idades compreendidas entre 1 e 5 anos, esse percentual foi superior a 80%. Nos exames de seios da face incidências fronto-naso (FN) e mento-naso (MN), mais de 70% dos exames realizados em pacientes menores de 10 anos forneceram valores de Ka,e superiores a 1000 μGy. Os valores de PK,A encontrados em exames de tórax AP/PA/LAT, realizados em pacientes maiores de 1 ano de idade foram, normalmente, superiores a 2 cGy.cm2. Para pacientes entre 10 e 16 anos, o PK,A foi superior a 10 cGy.cm2. Nos exames de seios da face FN/MN, realizados em pacientes maiores de 1 ano de idade, os valores de PK,A foram, geralmente, maiores que 5 cGy . cm2. Para pacientes entre 10 e 16 anos de idade, cerca de 70% dos exames forneceram valores de PK,A maiores que 10 cGy . cm2. As doses nos órgãos e doses efetivas estimadas nos exames analisados mostraram a importância da colimação do campo de raios X, uma vez que tanto nos exames de tórax AP/PA/LAT, quanto nos exames de seios da face FN/MN, órgãos que não deveriam estar integralmente dentro do campo de radiação receberam doses relativamente altas. Exemplo disso é o caso da tireóide, órgão de moderada radiosensibilidade que, em um dos hospitais que utiliza cilindro de colimação nos exames de seios da face, recebeu dose menor que nos demais hospitais, apesar dos valores de Ka,e nesse hospital terem sido substancialmente maiores. Comparando os resultados encontrados no presente trabalho com levantamentos dosimétricos realizados em outras instituições do Brasil e exterior, constatou-se que os valores de Ka,e estimados foram abaixo dos encontrados em algumas instituições brasileiras e de países do primeiro mundo, como Inglaterra, Espanha e Itália. No entanto, os valores de PK,A e dose efetiva foram substancialmente maiores que os encontrados em outras instituições. Os resultados, de uma maneira geral, ressaltam a necessidade da otimização dos procedimentos radiográficos, com vista a diminuir a dose e, consequentemente, o risco para os pacientes pediátricos submetidos a exames convencionais nas instalações de Belo Horizonte
2

Dosimetria de pacientes pediátricos em exames de tomografia computadorizada de crânio

ARAÚJO, Max Well Caetano de 27 August 2015 (has links)
Submitted by Haroudo Xavier Filho (haroudo.xavierfo@ufpe.br) on 2016-04-22T18:09:16Z No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação final Max-FINAL .compressed.pdf: 3341309 bytes, checksum: d495284374075775bce6c91531257a7e (MD5) / Made available in DSpace on 2016-04-22T18:09:16Z (GMT). No. of bitstreams: 2 license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Dissertação final Max-FINAL .compressed.pdf: 3341309 bytes, checksum: d495284374075775bce6c91531257a7e (MD5) Previous issue date: 2015-08-27 / A tomografia computadorizada (TC) é um dos métodos mais importantes de radiodiagnóstico, porém, pode resultar em altas doses absorvidas pelos pacientes quando comparado com exames radiográficos convencionais. O objetivo deste trabalho é avaliar as doses absorvidas pelos pacientes pediátricos nos procedimentos de tomografia computadorizada de crânio realizados em Recife, Brasil, utilizando o software de simulação computacional CALDose_XCT. Os parâmetros de irradiação para os procedimentos de TC de crânio pediátrico de 108 pacientes foram coletados e divididos nas seguintes faixas etárias: <1; 1 a 5; 5 a 10; e 10 a 15 anos de idade. Os valores de índice volumétrico de kerma ar em TC (CVOL) e produto kerma ar-comprimento para exames completos de TC (PKL,CT) foram estimados para cada exame e comparados com os níveis de referência internacional. Foram estimados os valores das doses absorvidos por órgãos relevantes (cristalino, cérebro, mucosa oral e glândulas salivares) utilizando o CALDose_XCT. Outra simulação foi realizada utilizando um fantoma de cabeça com inclinação de 18º para avaliar a redução da dose absorvida quando se utiliza a inclinação do gantry ou da cabeça do paciente. Os parâmetros de irradiação selecionados na maioria dos exames pediátricos avaliados não estão otimizados, já que foram observados valores maiores ou iguais aos parâmetros recomendados para exames em adultos. A maioria dos valores estimados de CVOL foram menores que os níveis de referência referência internacionais para exames pediátricos de TC. Por outro lado, situação inversa ocorreu com os valores de PKL,CT, devido ao uso de valores elevados de comprimento de varredura, em alguns casos maiores que a cabeça inteira do paciente. A maioria dos exames avaliados resultou em valores estimados de PKL,CT acima dos limites recomendados. A simulação da inclinação da cabeça dos pacientes pediátricos para exames de crânio resultou em redução da dose absorvida pelos olhos, mucosa oral e glândulas salivares, demostrando ser um método eficiente para otimização da proteção radiológica nestes procedimentos. Deste modo, ressalta-se a importância de implementação de um programa de garantia de qualidade no serviço, com o objetivo de otimizar os procedimentos e reduzir o detrimento para os pacientes pediátricos submetidos a exames de tomografia computadorizada. / The computed tomography (CT) is one of the most important methods for radio diagnostics, resulting, however, in high absorbed doses to the patients. The objective of this work is to evaluate the pediatric head CT examinations performed at one hospital in Recife, Brazil, and to estimate the mean absorbed doses to organs using the computational simulation software CALDose_XCT. The irradiation parameters used with 108 pediatric head CT examinations were registered and divided in the following age ranges: <1; 1 to 5; 5 to 10; and 10 to 15 years-old. The volume CT air kerma index (CVOL) and the air kerma-length product for full CT examinations (PKL,CT) were estimated to each examination and compared to international diagnostic reference levels. The mean absorbed doses to relevant organs (eye lens, brain, oral mucosa and salivary glands) were simulated using CALDose_XCT. Another simulation was made using a head phantom tilt of 18º, in order to evaluate the dose reduction to some organs using either the gantry or head tilt. The results showed that the irradiation parameters used in the most of the examinations are not optimized, since it was possible to observe tube potential and current-time product values higher than the recommended values to adult examinations. Most of the CVOL values were lower than the international reference levels for pediatric CT examinations. On the other hand, the contrary was observed with the PKL,CT, due to the use of large scan ranges, in some cases, bigger than the patient’s entire head. The simulation of the patient head tilt resulted in absorbed dose reduction to the eyes, oral mucosa and salivary glands, showing to be an efficient method to optimize the radiological protection of pediatric CT examinations. Thus, it can be highlighted the importance of a quality assurance program in the service, with the objective of optimizing the procedures and reducing the risk to the pediatric patients.
3

Avaliação de dose de entrada na pele em pacientes pediátricos através de medidas dosimétricas

Oliveira, Ana Luiza da Rosa de 18 April 2008 (has links)
A grande utilização de exames de diagnóstico por imagem em crianças trouxe à tona a preocupação com a crescente dose de radiação absorvida na realização de um exame radiográfico. O objetivo desta pesquisa foi realizar avaliação das práticas de raios X na radiologia pediátrica, visando a otimização dos procedimentos radiológicos e a produção de imagens com qualidade para o diagnóstico com a menor dose ao paciente. A metodologia foi baseada no acompanhamento de exames pediátricos e medidas dosimétricas através do uso de dosímetros termoluminescentes TLDs e software específico (DoseCal) para a constatação da realidade dos serviços de radiologia pediátrica. Medidas de pacientes pediátricos em exames radiográficos de tórax foram realizadas em um hospital público de Curitiba e em uma clínica em Cascavel. Grupos com diferentes faixas etárias foram formados na avaliação de exames rotineiros de tórax nas projeções AP/PA e LAT, e ossos da face na projeção lateral, onde foram divididos em grupos de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. As doses obtidas através do software DoseCal foram comparadas entre si para determinar sua variabilidade. A DEP determinada pelos TLDs foi comparada com os valores de referência dados pela comunidade européia para verificar as doses utilizadas. Os valores de dose para crianças de até 1 ano apresentaram-se altos em comparação com os demais grupos avaliados, um fator justificado em partes pela limitação dos equipamentos utilizados. Na radiologia convencional os valores obtidos através dos TLDs foram satisfatórios, obedecendo a referência máxima descrita pela comissão européia. Na radiologia digital indireta obtivemos valores acima dos referenciados, fator este resultante da implantação e da adaptação das técnicas radiológicas a nova forma de captação de imagem. Concluí-se que o aprimoramento técnico das equipes em radiologia pediátrica é uma das melhores maneiras de se obter bons resultados na diminuição da dose. / The great use of examinations of diagnosis for image in children brought the concern with the increasing dose of radiation absorbed in the accomplishment of a radiographic examination. The objective of this research is to carry through evaluation of the practical ones of x-rays in pediatric radiology, aiming at to optimize the radiological rocedures and the production of images with quality for the diagnosis with the lesser dose to the patient. The methodology is based on the accompaniment of pediatric examinations and dosimetry measures through the use of dosemeters TLD and specific software (DoseCal) for the evidence of the reality in a radiology service. Measures of pediatric patients in radiographic examinations of thorax had been carried through in a public hospital in the Curitiba. Groups with different age groups had been formed in the evaluation of routine examinations of thorax in projections AP/PA and LAT, where they are divided in groups of 0-1 year, 1-5 years, 5-10 years and 10-15 years. Part of the carried through examinations had been evaluated with thermoluminescence dosemeters TLD-100 for the collection of the entrance surface dose (ESD). The measured doses are compared with the gotten ones with the DoseCal software, that makes the calculation of dose for each patient from the income of the device of rays X. The ESD is evaluated always that it has diagnostic quality in the radiographic image. The objective is to verify if the minimum requirements had been reached, for a good quality of image and bringing a small dose to the patient, as party to suit of to optimize procedures.
4

Simulação Monte Carlo de cenários de radiologia intervencionista pediátrica no código MCNPX

Cavalcante, Fernanda Rocha 21 February 2017 (has links)
Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Interventional radiology consists of minimally invasive procedures guided by real-time X-ray imaging of a region of the patient to be diagnosed or treated. Since it is a practice that uses ionizing radiation, performing these procedures should follow the three basic principles of radioprotection, which are justification, optimization (medical exposure), and dose limitation (occupational exposure). Interventional procedures in children with congenital heart defects are justified by substituting other high-risk procedures. However, as these procedures are responsible for high doses in the patient and individuals occupationally exposed (IOE), it is important to evaluate the medical exposures of pediatric individuals due to a greater susceptibility to radiation damage in these individuals who present a rapid metabolism and closer proximity of the organs. In addition, the longer life expectancy in children allows more time for any harmful effects of radiation, such as cancer, to manifest. Because direct dose measurement within the human body is difficult or impractical, the Monte Carlo simulation of radiation transport is a useful tool in estimating dosimetric protection quantities (H T and E) in anthropomorphic phantoms representing the anatomy of the human body. In addition, it is possible to calculate conversion coefficients that relate protection quantities with measurable quantities, such as the kerma-area product (PKA). In this work, we modelled paediatric interventional cardiology scenarios using the MCNPX code and a pair of adult and paediatric hybrid anthropomorphic phantoms (newborn, 1 year and 5 year) to evaluate medical and occupational exposures. The results obtained in this work show conversion coefficients H T /PKA and E/PKA of 5 to 16 times higher than the values obtained in the literature for interventional procedures performed in adult patients. In addition, we estimate the influence of personal protective equipment (lead apron, thyroid shield and lead glasses) on occupational exposures, which contribute to reduction of H T doses in the physician up to 98% (gonads and thyroid), when used. / A radiologia intervencionista consiste de procedimentos minimamente invasivos guiados por imagens de raios X em tempo real de uma região do paciente a ser diagnosticada ou tratada. Por ser uma prática que utiliza radiação ionizante, a realização destes procedimentos deve seguir os três princípios básicos de radioproteção, que são a justificação, otimização (exposição do paciente) e limitação de dose (exposição do médico). Os procedimentos intervencionistas em crianças com cardiopatias congênitas são justificáveis por substituírem outros procedimentos de alto risco. Entretanto, conforme estes procedimentos são responsáveis por altas doses no paciente, além dos indivíduos ocupacionalmente expostos (IOE), é importante avaliar as exposições médicas de indivíduos pediátricos devido uma maior susceptibilidade de ocorrência de danos provocados pela radiação nestes indivíduos, que apresentam metabolismo rápido e maior proximidade anatômica dos órgãos. Além disso, a maior expectativa de vida das crianças induz uma maior probabilidade de ocorrência de efeitos estocásticos tardios como o câncer. Devido à medição direta da dose dentro do corpo humano ser difícil ou impraticável, a simulação Monte Carlo do transporte de radiação é uma ferramenta útil na estimativa de grandezas dosimétricas de proteção (H T e E) em simuladores antropomórficos que representam a anatomia do corpo humano. Além disso, é possível calcular coeficientes de conversão que relacionam grandezas de proteção com grandezas mensuráveis, como o produto kerma-área (PKA). Neste trabalho, modelamos cenários de cardiologia intervencionista pediátrica utilizando o código MCNPX e uma dupla de simuladores antropomórficos híbridos adulto e pediátrico (recém-nascido, de 1 e 5 anos) para avaliar as exposições médicas e ocupacionais. Os resultados obtidos neste trabalho mostram coeficientes de conversão H T /PKA e E/PKA de 5 a 16 vezes maiores que os valores obtidos na literatura para procedimentos intervencionistas realizados em pacientes adultos. Além disso, estimamos a influência dos equipamentos de proteção individual (avental, óculos plumbíferos e protetor de tireoide) nas exposições ocupacionais, que contribuem para redução das doses H T no médico em até 98% (gônadas e tireoide), quando utilizados.

Page generated in 0.4953 seconds