• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 5
  • 4
  • 2
  • 1
  • Tagged with
  • 56
  • 56
  • 41
  • 37
  • 16
  • 15
  • 14
  • 12
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise da estabilidade de cor e rugosidade de superfície de compósitos submetidos à fumaça de cigarro / Color stability and surface roughness of dental composites exposed to cigarette smoke

Carla Cecília Alandia Román 29 November 2011 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor e rugosidade de superfície de 3 compósitos odontológicos com partículas diferentes: nanohíbrido (Tetric N-Ceram - Ivoclar Vivadent), híbrido (Z250 - 3M ESPE) e microhíbrido com matriz silorano (Filtek P90 3M - ESPE), submetidos à fumaça de cigarro. Para isso, foram obtidos 60 corpos-de-prova (8mm de diâmetro X 2mm de espessura), 20 para cada tipo de material restaurador utilizado, dos quais 10 receberam polimento com lixas dágua em abrasividades decrescentes (Grupo1) e a outra metade não foi submetida a nenhum tipo de acabamento/polimento ficando sob efeito apenas de uma matriz de poliéster (Grupo 2). Após armazenamento dos corpos de prova em água destilada a 37°C por 24 horas, foram realizadas as primeiras leituras de cor (Colorímetro Vita Easy Shade) na escala de cor CIEL*a*b* e rugosidade superficial (Rugosímetro Surfcorder SE 1700 - Kosakalab). Em seguida, as amostras foram expostas à fumaça de 20 cigarros por um período de 10 minutos cada, (Marlboro - Philip Morris), sendo que entre um cigarro e outro as amostras foram submetidas à escovação em dispositivo padronizado e lavagem em água corrente. Após ação do número total de cigarros, foram realizadas leituras finais de cor e rugosidade. Os valores de &Delta;E, &Delta;L, &Delta;a e &Delta;b foram analisados estatisticamente utilizando 2 way ANOVA e Teste de Bonferroni (p<0.05) e os valores de rugosidade média (Ra) foram analisados isoladamente para cada tipo de material (teste t Student, p < 0.05). Verificou-se que o compósito Tetric N apresentou maior alteração de cor, em níveis clinicamente inaceitáveis (&Delta;E>3,3) e de rugosidade de superfície em relação aos demais compósitos quando utilizada a tira de poliéster como acabamento. Concluiu-se que a ausência de polimento aumenta a capacidade manchadora do cigarro sobre todos os compósitos e a rugosidade de superfície dos materiais, com exceção de P90. / The purpose of this study was to evaluate the color stability and surface roughness of three dental composites with different type of fillers: Nanohybrid (Tetric N-Ceram), Hybrid (Filtek Z250-3M ESPE) and Microhybrid silorane based composite (Filtek P90- 3M ESPE), exposed to cigarette smoke. 20 specimens (8mm diameter X 2mm thickness) of each material were prepared and separated into two groups (n=10) according to the surface treatment : Group 1- polymerization through a polyester film strip and polishing with water sandpaper in decreasing abrasiveness (600, 800 e 1200); and Group 2- polymerization through a polyester film strip, without any polishing. After immersion in destilled water 37° for 24 hours, baseline color of all specimens was measured using reflectance spectrophotometer (Easy Shade - Vita) with CIEL*a*b* system, surface roughness was also measured using a rugosimeter (SJ-201P Mitutoyo, Tokyo, Japan). After base line measurements, the specimens were exposed to smoke from 20 cigarettes in 10 minutes each, (Marlboro - Philip Morris), between one cigarette and other, the specimens were submitted to brushing in a standardized device and washed with water. After the action of the total number of cigarettes, final measurements of color and surface roughness were performed. Values of &Delta;E, &Delta;L, &Delta;a e &Delta;b were statistically analyzed using 2 way ANOVA e Teste de Bonferroni (p<0.05) and values of average surface roughness (Ra) were analyzed separately for each type of material (teste t Student, p < 0.05). It was found that the composite Tetric N-Ceram showed increased of surface roughness and greater color change in clinically unacceptable levels (&Delta;E>3,3), in comparison with the other composites when used the polyester strip without polishing. It was concluded that the absence of polishing increases the cigarette staining and surface roughness on all composites except for Filtek P90.
12

Avaliação da íris de prótese ocular obtida através de imagem digitalizada impressa em papel fotográfico / Iris evaluation of ocular prosthesis obtained through digitalized image printed in photographic paper

Reis, Ricardo Cesar dos 11 April 2008 (has links)
A reprodução fiel da íris do olho remanescente na confecção da prótese ocular é fator fundamental no resultado estético e na dissimulação da perda para os pacientes afetados. Este trabalho apresenta uma nova técnica de confecção da íris protética, substituindo a pintura tradicional da mesma, pela imagem digitalizada da íris remanescente, obtida através de fotografia impressa em papel fotográfico. Decidiu-se avaliar a estabilidade das cores, comparando-se a técnica de pintura com a obtida através da fotografia digital, sob a ação de dois fatores: ação térmica do ciclo de polimerização da resina acrílica na confecção da prótese e a incidência da luz solar, principal agente de fotodegradação que compromete a longevidade das próteses oculares, através de teste de envelhecimento acelerado. Foram assim, confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: pintura e fotografia, nas cores azul, amarelo, preto, marrom e verde. Foi realizada leitura colorimétrica inicial e após submetê-los às condições térmicas de polimerização. Posteriormente os corpos de prova foram testados durante três semanas através de ensaio de envelhecimento acelerado artificialmente com radiação ultravioleta A, com leituras colorimétricas semanais. A análise estatística sugere que, após a polimerização, as cores amarelo e marrom apresentaram diferenças significativas entre os grupos, sendo que, a cor amarelo na amostra pintura apresentou uma degradação um pouco acima do nível clinicamente aceitável. Após o ensaio de envelhecimento, não houve diferença significativa entre as amostras pintura e fotografia para as cores verde e amarelo, com alteração um pouco acima do nível clinicamente aceitável. Para as cores marrom e preto ocorreram diferenças significantes, com variações em níveis clinicamente aceitáveis; para a cor azul em níveis elevados, inviáveis clinicamente tanto na fotografia como na pintura. / The accurate iris reproduction in the making of ocular prosthesis for the remaining eye is a fundamental factor for the loss dissimulation aesthetic result in affected patients. This paper presents a new technique for the making of prosthetic iris that consists in substituting the traditional painting of the prosthesis for a digitalized image of the remaining iris, obtained through a picture printed in a photographic paper. It was decided to evaluate the stability of the colors by comparing the painting technique with the digital picture, for this two factors were considered: thermal conditions of the acrylic resin polymerization cycle in the prosthesis making and incidence of the sun light, which is the main photo degradation agent that affect the longevity of the ocular prosthesis, through the accelerated aging test. Then proof bodies simulating the prosthetic iris were made and divided into two groups: painted (in the colors blue, yellow, black, brown and green) and picture. An initial colorimetric scanning was made before and after submitting the bodies to the thermal conditions of the polymerization process. The proof bodies were then tested artificially for three weeks using the accelerated aging with A-ultraviolet radiation technique and proceeding to colorimetric scans weekly. Statistical analysis suggests that after the temperature action in the polymerization cycle, the yellow and brown color presented significative alteration between both groups and the yellow color in the painted presented degradation slightly above the acceptable clinical level. After the aging test, there was no significant difference between the samples in both groups for the green and yellow colors, however, for the brown and black colors significant differences were observed, with variations in clinically acceptable levels, and for blue color in high levels, clinically impracticable, in both groups.
13

Estudo longitudinal da influência da ação de soluções fluoretadas sobre alteração de cor e rugosidade de superfície de compósitos odontológicos / Longitudinal study of the influence of action of fluoride solution on color change and surface roughness of dental composites

Mundim, Fabrício Mariano 16 May 2011 (has links)
A doença cárie pode ser tratada com tratamento preventivo e ou tratamento restaurador. Para o tratamento preventivo, pode-se lançar mão da utilização do flúor, sendo sua utilização bastante difundida na Odontologia como eficaz método de promoção de saúde bucal. Já para o tratamento restaurador, utilizam-se materiais restauradores, sendo os compósitos odontológicos umas das principais escolhas entre os materiais restauradores estéticos usados na Odontologia. O objetivo deste estudo foi avaliar a ação de soluções fluoretadas na estabilidade de cor, rugosidade de superfície e análise qualitativa por microscopia eletrônica por varredura de compósitos odontológicos. Após confecção e polimento, os corpos de prova foram imersos em água destilada (controle), flúor fosfato acidulado (1,23%), gel fluoretado neutro (2%) e solução de flúor para bochechos diário (0,05%) por períodos de simulação correspondentes a 1 a 5 anos de uso clínico da solução fluoretada. Foram realizadas leituras de cor (&Delta;E), rugosidade de superfície (Ra) e microscopia eletrônica de varredura previamente e posteriormente a cada ano de ciclagem com as soluções fluoretadas estudadas. Após análise estatística (3-way ANOVA com medidas repetidas Bonferroni nível de significância em p<0.05), observou-se que todos os compósitos estudados apresentaram discreta alteração de cor, dentro do limite clinicamente aceitável (&Delta;E<3,3), sendo crescente de acordo com os anos de simulação clínica de 1 até 5 anos. Quanto à rugosidade, observou-se um padrão de comportamento não homogêneo, sendo, após 5 anos de simulação de uso clínico das soluções fluoretadas, menor que a rugosidade de superfície necessária para causar um aumento da retenção de biofilme dentário (Ra>0,2 &mu;m) para todos os compósitos analisados. A análise das fotomicrografias demonstrou o aparecimento de pequenas depressões na superfície das amostras e penetração de água (solvente) no interior dos compósitos diretos. Conclui-se que a alteração de cor dos compósitos foi clinicamente aceitável e a alteração de rugosidade de superfície não é clinicamente significante após imersão em todas as soluções fluoretadas e tempos estudados. / Dental caries can be treated with preventive treatment or restorative treatment. For preventive treatment, we can resort to the use of fluoride, and its widespread use in Dentistry as an effective method of promoting oral health. As for the restorative treatment, are used restorative materials, dental composites are one of the first choices among the materials used in aesthetic restorative dentistry. The aim of this study was to evaluate the effect of fluoride solution in color stability, surface roughness and qualitative analysis by scanning electron microscopy of dental composites. After preparation and polishing, the specimens were immersed in distilled water (control), acidulated phosphate fluoride (1.23%), neutral sodium fluoride gel (2%) and fluoride mouthwashes for daily (0.05%) for periods simulation corresponding to 1 to 5 years of clinical use of fluoride solution. Readings were taken in color (&Delta;E), surface roughness (Ra) and scanning electron microscopy before and after each year of cycling with the fluoride solution studied. After statistical analysis (3-way repeated measures ANOVA - Bonferroni - a significance level of p<0.05), was observed that all the composites studied showed a slight color change, within clinically acceptable (&Delta;E<3.3), being increased according to the years of clinical simulation from 1 to 5 years. As for the roughness, there was a pattern of behavior is not homogeneous, and, after five years of simulated clinical use of fluoride solution, smaller than the surface roughness required to cause an increased retention of dental plaque (Ra>0.2 &mu;m) for all composites analyzed. The analysis of the photomicrographs showed the appearance of small depressions on the surface and penetration of water (solvent) within the direct composites. We conclude that the color change of the composites was clinically acceptable and the surface roughness change is not clinically significant after immersion in all fluoride solution and times studied.
14

Desenvolvimento e avaliação colorimétrica de íris digitalizada obtida através de impressão em etiqueta autocolante e em adesivo / Development and colorimetric evaluation of iris scanned obtained through sticker printing and adhesive

Reis, Ricardo Cesar dos 06 February 2013 (has links)
Um dos fatores imprescindíveis no resultado estético satisfatório do tratamento reabilitador protético ocular é a reprodução fiel da íris do olho remanescente na íris protética. É a dissimulação da perda para os pacientes afetados. Este trabalho apresenta duas novas técnicas de confecção da íris protética, utilizando imagem digitalizada da íris remanescente, obtida por meio de imagem fotográfica impressa em etiqueta autocolante e em adesivo. Em função da fotodegradação que compromete a longevidade das próteses oculares, decidiu-se avaliar a estabilidade das cores, comparando-se ambas as técnicas, através de teste de envelhecimento acelerado. Para os ensaios foram confeccionados corpos de prova simulando a íris protética, divididos em dois grupos: adesivo e etiqueta autocolante, nas cores verde, azul, marrom e preto. A variação do grau de degradação foi avaliada por leitura colorimétrica inicial e, em três intervalos semanais durante o envelhecimento artificial com radiação ultravioleta. A análise estatística sugere que quando as cores foram avaliadas em função do período de ensaio de envelhecimento artificial, somente na cor azul no grupo adesivo houve diferença estatisticamente significante. Quando avaliadas em função do grupo e período de ensaio, os testes estatísticos indicam que não houve diferença entre as cores entre adesivo. Nenhuma das cores entre os grupos apresentou uma degradação de cor acima do nível clinicamente aceitável. / One of the essential factors in satisfactory final result of ocular prosthetic rehabilitation treatment is a faithful reproduction of the iris of the eye remaining in prosthetic iris. It concealment loss for affected patients. This paper presents two new techniques to manufacture prosthetic iris, using the remaining iris scanned image, obtained by photographic image printed sticker and adhesive. Depending on the photo degradation that compromises the longevity of artificial eyes, decided to evaluate the stability of colors, comparing both techniques, through accelerated aging test. For the tests were prepared specimens simulating prosthetic iris, divided into two groups: adhesive sticker and, in green, blue, brown and black. The variation of the degree of degradation was evaluated by colorimetric reading before and after and three weekly intervals during aging with artificial ultraviolet radiation. Statistical analysis suggests that when the colors were evaluated according to the period of artificial aging test, only in blue color in the adhesive group difference was statistically significant. When evaluated as a function of group and trial period, the statistical tests indicate no difference between the colors of adhesive. None of the colors between the groups showed color degradation above the clinically acceptable level.
15

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Pâmela Carbone Mello 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
16

Avaliação da resistência à abrasão, microdureza superficial e estabilidade de cor de dentes artificiais de resina acrílica / Evaluation of the abrasion resistance, superficial microhardness and color stability of acrylic resin artificial teeth.

Mello, Pâmela Carbone 20 December 2007 (has links)
O objetivo deste trabalho foi avaliar in vitro a resistência a abrasão, a microdureza superficial e a estabilidade de cor de dentes artificiais de resina acrílica. Sete grupos (1- Biolux, 2- Trilux, 3- Blue Dent, 4- Biocler, 5- Orthosit-Vivodent, 6- Postaris-Antaris, 7- Gnathostar-Ivostar), compostos de 12 pre-molares superiores de cada fabricante, sendo 6 contra antagonistas metálicos (Ni-Cr) e 6 contra antagonistas de resina indireta (Solidex), foram delineados em um perfilômetro, antes e após serem submetidos ao ensaio de abrasão. A diferença linear entre a primeira e a segunda leitura foi medida com um paquímetro digital (precisao 0,01mm). Após a análise estatística (análise de variância, teste de Tukey-Kramer, nível de significancia em p<0,05), observou-se que houve diferenças estatísticas significantes entre os grupos e que a marca Postaris apresentou os menores valores de desgaste contra ambos os antagonistas (R=2,33±0,91&micro;m e M=1,78±0,42&micro;m). Para a análise da microdureza superficial Vickers, foram utilizados 6 incisivos laterais superiores de cada marca e 3 leituras (terços incisal, médio e cervical) foram feitas com o auxílio de um microdurômetro. As médias de microdureza superficial Vickers foram submetidas a análise estatística (nível de significancia p<0,05) e com os resultados obtidos concluiu-se que o grupo Biolux (22,1±0,91VHN) seguido do Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) e Biocler (21,0±1,80VHN) apresentaram maiores valores de dureza diferenciando-se do Vivodent (19,1±0,99VHN) e Blue Dent (18,9±1,54VHN), menos duros. Para o ensaio de estabilidade de cor foram utilizados 6 incisivos centrais superiores direitos de cada marca comercial (n=42), submetidos ao processo de envelhecimento artificial acelerado. O aparelho de leitura de cor utilizado foi um Espectrocolorímetro Portátil Modelo Color Guide 45/0 (BYK-Gardner, Alemanha). Cada dente teve sua cor lida antes e imediatamente após o ensaio de envelhecimento artificial. Os valores de &Delta;E foram submetidos a análise estatística com auxílio do programa JMP 5.1 (SAS Institute, EUA) e mostraram que houve diferenças estatisticamente significantes entres os grupos e que apenas a marca Blue Dent (4,37±0,32) apresentou valores de &Delta;E>3,3 considerado, segunda a literatura, clinicamente inaceitável. Para os grupos que tiveram alterações clinicamente aceitáveis, o grupo Antaris/Postaris teve a maior variação de cor (&Delta;E=2,73±0,96) e o grupo Biolux apresentou a menor variação de cor (1,39±0,27). Dentro das limitações da metodologia empregada, concluiu-se que o antagonista utilizado (metal ou resina) influencia a escolha do dente artificial, e que os dentes artificiais testados tem comportamentos diferentes quanto a resistência a abrasão, microdureza superficial e estabilidade de cor. / The objective of this work was to evaluate in vitro the abrasion resistance, the superficial microhardness and the color stability of acrylic resin artificial teeth. Seven groups (1-Biolux, 2 - Trilux, 3 - Blue Dent, 4 - Biocler, 5 - Orthosit-Vivodent, 6 - Postaris-Antaris, 7 - Gnathostar-Ivostar), composed of 12 upper premolar for each manufacturer\'s, being 6 against metallic antagonists (Ni-Cr) and 6 against indirect resin (Solidex) antagonists, were delineated in a perfilometer, before and after the abrasion test. The linear difference between the first and the second readings was measured with a digital calliper (0,01mm precision). After the statistical analysis (variance analysis, Tukey-Kramer\'s test, p<0.05), it was observed that there were significant differences among the groups and that the trademark Postaris presented the smallest wear values against both antagonists (R=2,33±0,91&micro;m and M=1,78±0,42&micro;m). For Vickers superficial microhardness, 6 lateral upper incisors of each mark and 3 readings were used (incisal, medium, and cervical thirds) done with the microdurometer. The averages of Vickers superficial microhardness were submitted to the statistical analysis (p<0.05) and the obtained results show that the group Biolux (22,1±0,91VHN) followed by Antaris (21,9±1,58VHN), Ivostar (21,1±0,98VHN) and Biocler (21,0±1,80VHN) presented higher values, differing from Vivodent (19,1±0,99VHN) and Blue Dent (18,9±1,54VHN), less harders. For the color stability test 6 upper right central incisors of each commercial mark were used (n=42), submitted to the accelerated artificial aging process. The apparel for color reading was a Portable Spectruncolorimeter Model Color Guide 45/0 (BYK-Gardner, Germany). Each tooth had his color read before and immediately after the artificial aging. The &Delta;E values were submitted to the statistical analysis with JMP 5.1 (HEALTHY Institute, USA) software and show that significant differences were found among the groups and that only Blue Dent (4,37±0,32) presented clinically unacceptable values of &Delta;E (&Delta;E>3.3). For the groups that had clinically acceptable color alterations, the Antaris/Postaris group had the largest color variation (&Delta;E=2.73±0.96) and the Biolux group presented to smallest color variation (&Delta;E=1.39±0.27). Within the limitations of the methodology, was concluded that the antagonist (metal or resin) influence the choice of the artificial tooth, and that the tested artificial teeth have different behaviors for the abrasion resistance, superficial microhardness and color stability.
17

An In-Vitro Study Assessing the Color Stability of Different Provisional Crown and Bridge Restorative materials.

Barbara, Ndagire. January 2006 (has links)
<p><font face="TimesNewRomanPSMT"> <p align="left">The aim of this study was to investigate the color stability of two provisional restorative materials used in crown and bridge cases upon exposure to different tea staining solutions and to evaluate the effectiveness of a polishing technique in removing the tea stains from the stained provisional restorative materials.</p> </font></p>
18

An In-Vitro Study Assessing the Color Stability of Different Provisional Crown and Bridge Restorative materials.

Barbara, Ndagire. January 2006 (has links)
<p><font face="TimesNewRomanPSMT"> <p align="left">The aim of this study was to investigate the color stability of two provisional restorative materials used in crown and bridge cases upon exposure to different tea staining solutions and to evaluate the effectiveness of a polishing technique in removing the tea stains from the stained provisional restorative materials.</p> </font></p>
19

Estudo longitudinal da influência da ação de soluções fluoretadas sobre alteração de cor e rugosidade de superfície de compósitos odontológicos / Longitudinal study of the influence of action of fluoride solution on color change and surface roughness of dental composites

Fabrício Mariano Mundim 16 May 2011 (has links)
A doença cárie pode ser tratada com tratamento preventivo e ou tratamento restaurador. Para o tratamento preventivo, pode-se lançar mão da utilização do flúor, sendo sua utilização bastante difundida na Odontologia como eficaz método de promoção de saúde bucal. Já para o tratamento restaurador, utilizam-se materiais restauradores, sendo os compósitos odontológicos umas das principais escolhas entre os materiais restauradores estéticos usados na Odontologia. O objetivo deste estudo foi avaliar a ação de soluções fluoretadas na estabilidade de cor, rugosidade de superfície e análise qualitativa por microscopia eletrônica por varredura de compósitos odontológicos. Após confecção e polimento, os corpos de prova foram imersos em água destilada (controle), flúor fosfato acidulado (1,23%), gel fluoretado neutro (2%) e solução de flúor para bochechos diário (0,05%) por períodos de simulação correspondentes a 1 a 5 anos de uso clínico da solução fluoretada. Foram realizadas leituras de cor (&Delta;E), rugosidade de superfície (Ra) e microscopia eletrônica de varredura previamente e posteriormente a cada ano de ciclagem com as soluções fluoretadas estudadas. Após análise estatística (3-way ANOVA com medidas repetidas Bonferroni nível de significância em p<0.05), observou-se que todos os compósitos estudados apresentaram discreta alteração de cor, dentro do limite clinicamente aceitável (&Delta;E<3,3), sendo crescente de acordo com os anos de simulação clínica de 1 até 5 anos. Quanto à rugosidade, observou-se um padrão de comportamento não homogêneo, sendo, após 5 anos de simulação de uso clínico das soluções fluoretadas, menor que a rugosidade de superfície necessária para causar um aumento da retenção de biofilme dentário (Ra>0,2 &mu;m) para todos os compósitos analisados. A análise das fotomicrografias demonstrou o aparecimento de pequenas depressões na superfície das amostras e penetração de água (solvente) no interior dos compósitos diretos. Conclui-se que a alteração de cor dos compósitos foi clinicamente aceitável e a alteração de rugosidade de superfície não é clinicamente significante após imersão em todas as soluções fluoretadas e tempos estudados. / Dental caries can be treated with preventive treatment or restorative treatment. For preventive treatment, we can resort to the use of fluoride, and its widespread use in Dentistry as an effective method of promoting oral health. As for the restorative treatment, are used restorative materials, dental composites are one of the first choices among the materials used in aesthetic restorative dentistry. The aim of this study was to evaluate the effect of fluoride solution in color stability, surface roughness and qualitative analysis by scanning electron microscopy of dental composites. After preparation and polishing, the specimens were immersed in distilled water (control), acidulated phosphate fluoride (1.23%), neutral sodium fluoride gel (2%) and fluoride mouthwashes for daily (0.05%) for periods simulation corresponding to 1 to 5 years of clinical use of fluoride solution. Readings were taken in color (&Delta;E), surface roughness (Ra) and scanning electron microscopy before and after each year of cycling with the fluoride solution studied. After statistical analysis (3-way repeated measures ANOVA - Bonferroni - a significance level of p<0.05), was observed that all the composites studied showed a slight color change, within clinically acceptable (&Delta;E<3.3), being increased according to the years of clinical simulation from 1 to 5 years. As for the roughness, there was a pattern of behavior is not homogeneous, and, after five years of simulated clinical use of fluoride solution, smaller than the surface roughness required to cause an increased retention of dental plaque (Ra>0.2 &mu;m) for all composites analyzed. The analysis of the photomicrographs showed the appearance of small depressions on the surface and penetration of water (solvent) within the direct composites. We conclude that the color change of the composites was clinically acceptable and the surface roughness change is not clinically significant after immersion in all fluoride solution and times studied.
20

Avaliação da estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão / Avaliação da estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão / Evaluation of color stability and sorption of resin composites light-cured by halogen lamp and LED in different mediums of immersion / Evaluation of color stability and sorption of resin composites light-cured by halogen lamp and LED in different mediums of immersion

Rodrigo Prada Sant'Anna Guimarães 07 February 2006 (has links)
A demanda por restaurações estéticas tem aumentado consideravelmente nos últimos anos. Os materiais restauradores estéticos diretos, assim como novas fontes luminosas para sua ativação, têm sido cada vez mais utilizadas e vêm passando por uma série de modificações estruturais buscando a obtenção de melhores propriedades mecânicas e ópticas. Desta maneira, o presente estudo teve por objetivo avaliar a estabilidade de cor e sorção de compósitos fotoativados por luz halógena e por emissão de diodo em diferentes meios de imersão. Para isso, 120 corpos de prova utilizando os compósitos resinosos TPH Spectrum (Dentsply), Esthet-X (Dentsply) na cor A2 utilizando uma matriz de teflon e aço inox, ativadas por 03 fontes luminosas distintas (Fotopolimerizador de luz halógena QHL 75 Curing Lite, Dentsply; Fotopolimerizador de luz de diodo BIOLUX Standart II, Bio-Art e Fotopolimerizador de luz de diodo Smart Lite PS, Dentsply). Após todos corpos de prova terem sido submetidos à seqüência de acabamento, polimento, limpeza, pesagem inicial e leitura inicial de cor em um espectrofotômetro de reflectância foram armazenados por 07 dias a 37o C em água destilada (grupo da água destilada), café (grupo do café), coca-cola (grupo da coca-cola) e vinho tinto (grupo do vinho tinto). Completado o tempo de imersão os corpos de prova foram novamente lavados, pesados e levados ao espectrofotômetro para leitura final de cor. Após obtenção dos resultados finais de cor e peso foi calculada a estabilidade de cor e sorção de cada corpo de prova sendo posteriormente submetidos a tratamento estatístico (ANOVA e teste de Bonferroni com 5% de significância para estabilidade de cor e teste de Kruskal-Wallis com 5% de significância para sorção). Baseado nos resultados obtidos pode-se concluir existir diferença de estabilidade de cor a ponto de ser clinicamente perceptível em compósitos fotoativados por luz halógena e luz de diodo em diferentes meios de imersão. Os meios que mais provocaram alterações cromáticas em ordem decrescente, respectivamente, foram: vinho tinto, coca-cola, café e água destilada. Os corpos-de-prova fotoativados pelo aparelho BIOLUX Standart II apresentaram uma menor estabilidade de cor quando comparados com os demais. Ambos compósitos Esthet-X e TPH Spectrum mostraram acentuadas alterações cromáticas quando imersos em vinho tinto e coca-cola. O TPH Spectrum mostrou-se mais estável frente às alterações cromáticas. Para o experimento de sorção concluímos não haver diferença estatística. / The demand of aesthetics restorations has been considerable increased last years. The direct esthetic restorative materials and new kinds of light sources have been passing by innumerous structural modifications to obtain better optical and mechanical properties. The purpose of this study was to evaluate the color stability and sorption of resin composites light-cured by quartz-tungsten-halogen lamps and light-emitting diodes in different mediums of immersion. One hundred and twenty specimens using TPH Spectrum (Dentsply), Esthet-X (Dentsply) shade A2 were constructed by using a teflon and iron inoxidizable matrix light-cured by 03 distincts light sources (conventional halogen lamp light curing unit â QHL 75 Curing Lite, Dentsply; light emitting diode curing unit â BIOLUX Standart II, Bio-Art and light emitting diode curing unit â Smart Lite PS, Dentsply). All the specimens passed by procedures of finishing, polishing and initial weight and color measurements were done. After the color measurements done using a reflectance spectrophotometer the specimens were immersed for 07 days at 37o C in destiled water (destiled water group), coffee (coffee group), coke-cola (coke-cola group) and red wine (red wine group). Completed the immersion times the specimens were cleansed and final measurements of weigh and color were done. The percentage of sorption and the color stability were calculated and the values were submitted to statistic treatment (ANOVA and Bonferroni`s test with 5% of significance for color stability and Kruskal-Wallis`s test with 5% of significance for sorption). Based on the results of the study the authors concluded that existed difference of color stability clinically perceptible in composites light-cured by quartz-tungsten-halogen lamps and light-emitting diodes in different mediums of immersion. Red wine, coke-cola, coffee and destiled water, in order, showed the biggest values of discoloration. The specimens light-cured by BIOLUX Standart II unit showed lowest color stability than the others specimens. Esthet-X and TPH Spectrum showed high values of discoloration when they were immersed in red wine and coke-cola. TPH Spectrum showed more stable front of discolorations. To sorption experiment the authors concluded that there was no statistic difference.

Page generated in 0.0542 seconds