• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 44
  • 5
  • 4
  • 2
  • 1
  • Tagged with
  • 56
  • 56
  • 41
  • 37
  • 16
  • 15
  • 14
  • 12
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Färgstabilitet hos manuellt färginfiltrerad högtranslucent zirkonia efter upprepade bränningar / Color stability in manually color infiltrated translucent zirconia after repeated firings

Follin, Lydia, Hofmann, Christian January 2021 (has links)
Syfte: Syftet med föreliggande studie är att undersöka färgstabiliteten hos manuellt färginfiltrerad högtranslucent zirkonia efter upprepade bränningar.   Material och metod: Fem provkroppar av respektive fabrikat; Prettau® Zirconia (PZ) och M+W Zircon HT (MW) kapades fram ur ofärgade zirkonia-diskar. Provkropparna färgades in manuellt med färgen A3 och torkades därefter under en infraröd lampa. Provkropparna sintrades enligt fabrikanternas anvisningar och en första färgmätning utfördes med en spektrofotometer (VITA Easyshade Advance 4.0) mot en matt grå bakgrund. Där efter utfördes bränningar av provkropparna i fyra cykler. Efter varje cykel utfördes färgmätningar.Medelvärdena för L*a*b*c*h* registrerades. Formlerna CIE76 (∆E*ab) och CIEDE2000 (∆E*00) användes för att räkna ut färgskillnader efter bränncyklerna. Värdena registrerades i SPSS och analyserades med One-way ANOVA, Tukey’s test med en signifikansnivå på α=0,05.   Resultat: Statistiskt signifikanta skillnader (p<0,05) i färgförändring hittades både inom och mellan de båda grupperna (MW och PZ). Färgskillnaderna som uppmättes befann sig inom ramen för vad som anses som en acceptabel (∆E*ab≤2,7 och ∆E*00≤1,8) eller mycket god färgmatchning (∆E*ab≤1,2 och ∆E*00≤0,8).   Slutsats: Inom ramen för studiens begränsningar kan följande slutsatser dras: Upprepade bränningar påverkar färgen hos manuellt färginfiltrerad högtranslucent zirkonia. De färgförändringar som sker är inom ramen för vad som räknas som en ”acceptabel färgmatchning” eller ”mycket god färgmatchning” enligt aktuella gränsvärden. Färgförändringarna som sker är inte iögonfallande och har ringa betydelse kliniskt. Färgen och färgskillnader hos manuellt färginfiltrerad högtranslucent zirkonia är beroende av fabrikat. / Purpose: The purpose of this study is to investigate color stability in manually color infiltrated high translucent zirconia after repeated firings. Material and methods: Five specimens of each manufacturer; Prettau® Zirconia (PZ) and M+W Zircon HT (MW) were cut from uncolored zirconia discs. The specimens were manually colored with shade A3, and dried. The specimens were sintered and a first color measurement was performed with a spectrophotometer (VITA Easyshade Advance 4.0) against a matte gray background. Firings of the specimens were performed in four cycles. After each cycle, color measurements were performed. The mean values for L*a*b*c*h* ​​were registered. The formulas CIE76 (∆E*ab) and CIEDE2000 (∆E*00) were used to calculate color differences after firing cycles. The values were registered and analyzed with One-way ANOVA, Tukey's test with a level of significance at α=0.05.  Results: Statistically significant color differences (p<0.05) were found within and between groups (PZ and MW). The color differences measured were within the range of what is considered an acceptable match (∆E*ab≤2.7 and ∆E*00≤1.8) or a perfect match (∆E*ab≤1.2 and ∆E*00≤0.8).   Conclusion: Within the limitations of this study, the following conclusions can be drawn: Repeated firings affect the color in manually color infiltrated high translucent zirconia. The color changes that occur are within the range of what is considered an “acceptable match” or “perfect match” according to current thresholds. The color changes are not conspicuous and of little importance clinically. The color and color differences in manually color infiltrated high translucent zirconia are dependent on the brand.
32

Efeito do envelhecimento artificial acelerado na estabilidade de cor de cimentos resinosos para cimentação de laminados cerâmicos / Effect of accelerated artificial aging on color stability of resin cements for luting ceramic laminates

Silame, Francisca Daniele Jardilino 10 April 2013 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de cimentos resinosos para fixação de restaurações cerâmicas em diferentes espessuras submetidas ao envelhecimento artificial acelerado (EAA). Foram utilizados 60 molares humanos hígidos, cujas porções radiculares foram incluídas em matriz de PVC (15 mm de diâmetro) com resina acrílica e as faces oclusais foram planificadas, 30 em esmalte e 30 até dentina, sendo que 10 dentes de cada substrato foram considerados gruposcontrole para os dentes restaurados. Foram obtidos 40 corpos de prova em cerâmica (IPS e-max Ceram, Ivoclar Vivadent), com 0,5 mm e 1,0 mm, que foram separados aleatoriamente em dois grupos (n=10) segundo o tipo de cimento resinoso dual utilizado para fixação: convencional (Variolink II, Ivoclar/Vivadent) ou auto-adesivo (Rely-X Unicem, 3M ESPE). Além desses, foram obtidos 10 corpos de prova de cada cimento resinoso (0,5mm), considerado grupo-controle para os materiais. Todas as amostras foram mantidas em estufa a 37ºC por 24h, após o qual foram realizadas as leituras de cor iniciais (Vita EasyShade, VITA). Em seguida, foram submetidas ao EAA por 580 horas, após o qual novas leituras de cor foram realizadas. Foi avaliada estabilidade de cor e a luminosidade. Os dados de estabilidade de cor (&Delta;E) e luminosidade (&Delta;L) obtidos foram submetidos a análise estatística (2-way ANOVA, Bonferroni, p<0,05) e a comparação dos materiais com os grupos controles foi realizada utilizando 1-way ANOVA e teste de Tukey (p<0,05). O cimento dual convencional apresentou maior alteração de cor e luminosidade quando sob a restauração de 0,5mm, diferente estatisticamente (p<0,05) de restaurações de 1,0mm. Não houve diferença estatisticamente significante (p>0,05) quando comparados os materiais. Quando analisadas a estabilidade de cor e luminosidade dos grupos com restaurações em relação aos grupos-controle, verificou-se que ambos os cimentos apresentaram maiores alterações, diferente estatisticamente (p<0,05) dos demais grupos, com exceção ao grupo de 0,5mm em relação ao Grupo esmalte quando analisado o cimento dual convencional (p>0,05). Concluiu-se que quanto menor a espessura da restauração, maior a alteração de cor e de luminosidade do cimento dual convencional. As alterações do cimento autoadesivo não dependem da espessura da restauração. / The aim of this study was to evaluate the color stability of resin cements for luting ceramic restorations with different thicknesses submitted to accelerated artificial aging (AAA). Sixty sound human molars had their root portions embedded in PVC rings (15-mm diameter) with acrylic resin. Their occlusal surfaces were flattened according two substrates: 30 surfaces until enamel and 30 until dentin. Then, 10 teeth of each substrate were considered as control groups for restored teeth. Forty specimens of ceramic (IPS e-max Ceram, Ivoclar Vivadent) were obtained with two different thicknesses (0.5 mm and 1.0 mm) and were randomly separated into two groups (n = 10) according to the type of the Dual resin cement used for luting: conventional (Variolink II, Ivoclar / Vivadent) or self-adhesive (Rely-X Unicem, 3M ESPE). Also, 10 specimens (0.5 mm) of each cement were obtained to be considered as control groups for materials. All specimens were stored at 37º C for 24 hours, and initial color readings (Vita Easyshade, VITA) were performed. Then, they were submitted to AAA for 580 hours, and final color readings were taken. Color stability and brightness were evaluated. Data of color stability (&Delta;E) and brightness (&Delta;L) were statistically analyzed (2- way ANOVA, Bonferroni, p<0.05) and the comparison of materials with control groups was performed using one-way ANOVA and Tukeys test (p<0.05). The conventional dual cement showed the greatest change in color and brightness when under restorations of 0.5 mm, statistically different (p<0.05) to restorations of 1.0 mm. There was no statistically significant difference (p>0.05) when comparing materials. When analyzing the color stability and brightness of restorations groups compared to control groups, both cements showed greater changes, statistically different (p<0.05), than other groups, except for the group of 0.5 mm in relation to enamel group when the dual conventional cement was analyzed (p>0.05). It was concluded that the smaller the thickness of the restoration, the greater the color and brightness changes of the dual conventional cement. Changes of the self-adhesive cement do not depend on the thickness of the restoration.
33

Influência do envelhecimento artificial acelerada sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos odontológicos armazenados em diferentes ambientes e tempos de armazenagem / Influence of artificial accelerated aging on color stability, opacity and cross-link density of dental composites stored in different environment and over different times

Mundim, Fabrício Mariano 09 November 2007 (has links)
A evolução sofrida pelas resinas compostas, aliada à sua característica de restaurar a aparência natural dos dentes em relação à cor e opacidade, torna esses materiais uma das principais escolhas entre os materiais restauradores usados na odontologia. A estabilidade de cor e a opacidade assumem um papel crucial no sucesso do tratamento restaurador estético, pois a alteração destas características pode indicar a substituição das restaurações estéticas. Essas propriedades estão relacionadas ao grau de conversão desses materiais no momento da polimerização. O objetivo deste trabalho foi avaliar a influência do envelhecimento artificial acelerado sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos armazenados por 30 e 90 dias em ambientes diferentes (temperatura ambiente/geladeira). Foram utilizados 5 compósitos odontológicos em duas tonalidades: claras e escuras. As embalagens dos compósitos foram mantidas em temperatura ambiente (+/- 25ºC) e em geladeira (+/- 8ºC), sendo armazenados nestes ambientes por 30 e 90 dias, para posterior confecção dos corpos-de-prova (12 mm de diâmetro / 2 mm de espessura). Sobre essas amostras, foram realizadas as leituras da alteração de cor ( E), opacidade (OP), e densidade das ligações cruzadas, previamente e posteriormente a realização do procedimento de envelhecimento artificial acelerado. Após análise estatística (2-way ANOVA - Tukey - nível de significância em p<0.05), observou-se que compósitos QuiXfil Universal, Tetric EvoCeram C3 e SR Adoro A2, apresentaram valores para alteração de cor clinicamente inaceitável ( E 3,3). Quanto à opacidade, as resinas diretas, de tonalidades claras apresentaram menor opacidade que as tonalidades escuras enquanto que a resina indireta apresentou maior opacidade para a tonalidade clara que a escura. Quanto à densidade de ligações cruzadas, o envelhecimento artificial acelerado produziu um aumento na densidade de ligações cruzadas das resinas diretas. Concluiu-se que não houve um comportamento homogêneo dos materiais, em relação às propriedades estudadas, em função do tempo e ambiente de armazenagem sugerindo que a ação do envelhecimento é primordial e mais relevante para a alteração dos materiais ao longo do tempo. / The evolution of composite resins, allied to their characteristic of restoring the natural appearance of teeth regarding color and opacity, makes them one of the main materials of choice among the restorative materials used in dentistry. Color and opacity stability assume a crucial role in a successful aesthetic restoration treatment, since changes in these characteristics may indicate the replacement of aesthetic restorations. These properties are associated with these materials\' degree of conversion at the moment of polymerization. The purpose of this study was to evaluate the influence of artificial accelerated aging on color stability, opacity, and density of cross-links in composites stored for 30 and 90 days in different environments (room temperature/refrigerator). Five dental composites were used, with two shades: light and dark. Composite packages were kept in room temperature (+/- 25ºC) and in a refrigerator (+/- 8ºC), for 30 and 90 days, for posterior specimen fabrication (12 mm in diameter / 2 mm thick). Specimens were subjected to readings for color change ( E), opacity (OP), and cross-link density, before and after artificial accelerated aging. Statistical analysis (2-way ANOVA - Tukey - level of significance at p<0.05), revealed that QuiXfil Universal, Tetric EvoCeram C3, and SR Adoro A2 composites presented clinically unacceptable color changes ( E 3.3). Regarding opacity, light shade direct resins presented less opacity compared to dark shades, whereas light shade indirect resins presented more opacity than dark ones. As to cross-link density, artificial accelerated aging increased crosslink density in direct resins. It is concluded that the materials did not behave homogenously, in terms of the studied properties, under the effects of storage time and environment. This suggests that the effects of aging are imperative and more relevant to material changes over time.
34

"Estabilidade de cor de cerâmicas odontológicas submetidas ao processo de envelhecimento artificial acelerado após múltiplos ciclos de queima" / Color stability of ceramics restorations submitted to accelerated aging after multiple burn cycles

Fonseca, Karla Cristiane Vieira da 16 December 2005 (has links)
A estética tornou-se de fundamental importância nas últimas décadas, fazendo com que houvesse uma grande evolução nos materiais dentários e técnicas restauradoras para atender a esta exigência. As cerâmicas odontológicas são materiais estéticos e biocompatíveis, podendo ser uma ótima alternativa quando aplicadas a casos apropriadamente selecionados. O sucesso estético de uma restauração de cerâmica depende da caracterização de superfície, da integridade marginal, da forma anatômica e da coloração. O presente estudo teve o objetivo de avaliar a estabilidade de cor de dois tipos de restaurações em cerâmica odontológica, metalocerâmica e livre de metal, submetidas a múltiplos ciclos de queimas. Foram realizados 60 corpos-de-prova, sendo 30 na forma de metalocerâmicas e 30 livres de metal que foram divididas em três grupos de 10 amostras cada, sendo confeccionadas em duas, três e quatro queimas respectivamente. As leituras de cor foram realizadas em espectrofotômetro PCB 6807 BYK GARDNER antes e após envelhecimento artificial acelerado (Comexim Matérias Primas). Analisando-se inicialmente a influência do número de queimas sobre a cor da cerâmica odontológica, houve diferenças estatisticamente significantes para as coordenadas L* nas amostras metalocerâmicas, sendo que o grupo de 3 queimas foi o que apresentou diferenças em relação aos outros dois grupos. Para as amostras livres de metal, houve diferenças nas coordenadas L*, a* e b*, com comportamentos heterogêneos para as 3 coordenadas. Os resultados indicaram diferenças estatisticamente significantes na variação total de cor (&#8710;E) para as amostras de 3 e 4 queimas, comparando-se os tipos de restauração. Quando analisada a interferência do número de queimas de um mesmo tipo de restauração, não houve diferença estatisticamente significante para a amostra livre de metal. Para a amostra metalocerâmica, houve apenas diferença estatisticamente significante entre as amostras que receberam 2 e 3 queimas. Para a variação total nas coordenadas L*, a* e b* também houve variação de valores para os dois tipos de amostras e em relação aos ciclos de queimas. Concluiu-se que as pequenas diferenças estatisticamente significantes encontradas em alguns grupos não foram visíveis ao olho humano e portanto sem qualquer significado clínico (&#8710;E < 3,3). Além disso, os múltiplos ciclos de queima e o envelhecimento acelerado não modificaram de forma significativa a estabilidade de cor da cerâmica nas formas em que foi empregada (&#8710; < 1). / Esthetics has become essential over the past few decades, causing dental materials and restorative techniques to evolve significantly. Dental ceramics are esthetic and biocompatible materials which may be an excellent alternative for properly selected cases. The esthetic success of a ceramic’s restoration depends on surface characterization, marginal integrity, anatomic form, and color. This study aimed to assess the color stability of two types of dental ceramic restorations, metalloceramic and metal-free, submitted to multiple burn cycles. Sixty specimens were fabricated: 30 metalloceramic and 30 metal-free. The specimens were divided into 3 groups (n= 10) according to the number of burns (2, 3, and 4 burns). Color readings were performed using a PCB 6807 BYK GARDNER spectrophotometer before and after artificial accelerated aging (Comexim Raw Materials). By analyzing the influence of the number of burns over the dental ceramic’s color, statistically significant differences were found for the coordinate L* for the metalloceramic specimens, in the group of 3 burns, in relation to the other 2 groups. For the metal-free specimens, there were differences for the coordinates L*, a*, and b*, with heterogeneous compartments for the 3 coordinates. The results revealed statistically significant differences for total color variation (&#8710;E) for the 3 burns group, in comparison to the other types of restoration. When analyzing the specimens of a single type of material, in terms of the interference of the number of burns, the metal-free samples showed no statistically significant differences, whereas the metalloceramic samples showed difference only between those that received 2 and 3 burns. For the total variation of coordinates L*, a*, and b*, both materials showed a variation in those values and in relation to burn cycles. The small statistically significant differences found in some groups are invisible and present no clinical meaning (&#8710;E<3.3). In addition, the multiple burn cycles and accelerated aging did not modify significantly the ceramic’s color stability (&#8710;<1).
35

Influência do envelhecimento artificial acelerada sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos odontológicos armazenados em diferentes ambientes e tempos de armazenagem / Influence of artificial accelerated aging on color stability, opacity and cross-link density of dental composites stored in different environment and over different times

Fabrício Mariano Mundim 09 November 2007 (has links)
A evolução sofrida pelas resinas compostas, aliada à sua característica de restaurar a aparência natural dos dentes em relação à cor e opacidade, torna esses materiais uma das principais escolhas entre os materiais restauradores usados na odontologia. A estabilidade de cor e a opacidade assumem um papel crucial no sucesso do tratamento restaurador estético, pois a alteração destas características pode indicar a substituição das restaurações estéticas. Essas propriedades estão relacionadas ao grau de conversão desses materiais no momento da polimerização. O objetivo deste trabalho foi avaliar a influência do envelhecimento artificial acelerado sobre a estabilidade de cor, opacidade e densidade das ligações cruzadas de compósitos armazenados por 30 e 90 dias em ambientes diferentes (temperatura ambiente/geladeira). Foram utilizados 5 compósitos odontológicos em duas tonalidades: claras e escuras. As embalagens dos compósitos foram mantidas em temperatura ambiente (+/- 25ºC) e em geladeira (+/- 8ºC), sendo armazenados nestes ambientes por 30 e 90 dias, para posterior confecção dos corpos-de-prova (12 mm de diâmetro / 2 mm de espessura). Sobre essas amostras, foram realizadas as leituras da alteração de cor ( E), opacidade (OP), e densidade das ligações cruzadas, previamente e posteriormente a realização do procedimento de envelhecimento artificial acelerado. Após análise estatística (2-way ANOVA - Tukey - nível de significância em p<0.05), observou-se que compósitos QuiXfil Universal, Tetric EvoCeram C3 e SR Adoro A2, apresentaram valores para alteração de cor clinicamente inaceitável ( E 3,3). Quanto à opacidade, as resinas diretas, de tonalidades claras apresentaram menor opacidade que as tonalidades escuras enquanto que a resina indireta apresentou maior opacidade para a tonalidade clara que a escura. Quanto à densidade de ligações cruzadas, o envelhecimento artificial acelerado produziu um aumento na densidade de ligações cruzadas das resinas diretas. Concluiu-se que não houve um comportamento homogêneo dos materiais, em relação às propriedades estudadas, em função do tempo e ambiente de armazenagem sugerindo que a ação do envelhecimento é primordial e mais relevante para a alteração dos materiais ao longo do tempo. / The evolution of composite resins, allied to their characteristic of restoring the natural appearance of teeth regarding color and opacity, makes them one of the main materials of choice among the restorative materials used in dentistry. Color and opacity stability assume a crucial role in a successful aesthetic restoration treatment, since changes in these characteristics may indicate the replacement of aesthetic restorations. These properties are associated with these materials\' degree of conversion at the moment of polymerization. The purpose of this study was to evaluate the influence of artificial accelerated aging on color stability, opacity, and density of cross-links in composites stored for 30 and 90 days in different environments (room temperature/refrigerator). Five dental composites were used, with two shades: light and dark. Composite packages were kept in room temperature (+/- 25ºC) and in a refrigerator (+/- 8ºC), for 30 and 90 days, for posterior specimen fabrication (12 mm in diameter / 2 mm thick). Specimens were subjected to readings for color change ( E), opacity (OP), and cross-link density, before and after artificial accelerated aging. Statistical analysis (2-way ANOVA - Tukey - level of significance at p<0.05), revealed that QuiXfil Universal, Tetric EvoCeram C3, and SR Adoro A2 composites presented clinically unacceptable color changes ( E 3.3). Regarding opacity, light shade direct resins presented less opacity compared to dark shades, whereas light shade indirect resins presented more opacity than dark ones. As to cross-link density, artificial accelerated aging increased crosslink density in direct resins. It is concluded that the materials did not behave homogenously, in terms of the studied properties, under the effects of storage time and environment. This suggests that the effects of aging are imperative and more relevant to material changes over time.
36

"Estabilidade de cor de cerâmicas odontológicas submetidas ao processo de envelhecimento artificial acelerado após múltiplos ciclos de queima" / Color stability of ceramics restorations submitted to accelerated aging after multiple burn cycles

Karla Cristiane Vieira da Fonseca 16 December 2005 (has links)
A estética tornou-se de fundamental importância nas últimas décadas, fazendo com que houvesse uma grande evolução nos materiais dentários e técnicas restauradoras para atender a esta exigência. As cerâmicas odontológicas são materiais estéticos e biocompatíveis, podendo ser uma ótima alternativa quando aplicadas a casos apropriadamente selecionados. O sucesso estético de uma restauração de cerâmica depende da caracterização de superfície, da integridade marginal, da forma anatômica e da coloração. O presente estudo teve o objetivo de avaliar a estabilidade de cor de dois tipos de restaurações em cerâmica odontológica, metalocerâmica e livre de metal, submetidas a múltiplos ciclos de queimas. Foram realizados 60 corpos-de-prova, sendo 30 na forma de metalocerâmicas e 30 livres de metal que foram divididas em três grupos de 10 amostras cada, sendo confeccionadas em duas, três e quatro queimas respectivamente. As leituras de cor foram realizadas em espectrofotômetro PCB 6807 BYK GARDNER antes e após envelhecimento artificial acelerado (Comexim Matérias Primas). Analisando-se inicialmente a influência do número de queimas sobre a cor da cerâmica odontológica, houve diferenças estatisticamente significantes para as coordenadas L* nas amostras metalocerâmicas, sendo que o grupo de 3 queimas foi o que apresentou diferenças em relação aos outros dois grupos. Para as amostras livres de metal, houve diferenças nas coordenadas L*, a* e b*, com comportamentos heterogêneos para as 3 coordenadas. Os resultados indicaram diferenças estatisticamente significantes na variação total de cor (&#8710;E) para as amostras de 3 e 4 queimas, comparando-se os tipos de restauração. Quando analisada a interferência do número de queimas de um mesmo tipo de restauração, não houve diferença estatisticamente significante para a amostra livre de metal. Para a amostra metalocerâmica, houve apenas diferença estatisticamente significante entre as amostras que receberam 2 e 3 queimas. Para a variação total nas coordenadas L*, a* e b* também houve variação de valores para os dois tipos de amostras e em relação aos ciclos de queimas. Concluiu-se que as pequenas diferenças estatisticamente significantes encontradas em alguns grupos não foram visíveis ao olho humano e portanto sem qualquer significado clínico (&#8710;E < 3,3). Além disso, os múltiplos ciclos de queima e o envelhecimento acelerado não modificaram de forma significativa a estabilidade de cor da cerâmica nas formas em que foi empregada (&#8710; < 1). / Esthetics has become essential over the past few decades, causing dental materials and restorative techniques to evolve significantly. Dental ceramics are esthetic and biocompatible materials which may be an excellent alternative for properly selected cases. The esthetic success of a ceramic’s restoration depends on surface characterization, marginal integrity, anatomic form, and color. This study aimed to assess the color stability of two types of dental ceramic restorations, metalloceramic and metal-free, submitted to multiple burn cycles. Sixty specimens were fabricated: 30 metalloceramic and 30 metal-free. The specimens were divided into 3 groups (n= 10) according to the number of burns (2, 3, and 4 burns). Color readings were performed using a PCB 6807 BYK GARDNER spectrophotometer before and after artificial accelerated aging (Comexim Raw Materials). By analyzing the influence of the number of burns over the dental ceramic’s color, statistically significant differences were found for the coordinate L* for the metalloceramic specimens, in the group of 3 burns, in relation to the other 2 groups. For the metal-free specimens, there were differences for the coordinates L*, a*, and b*, with heterogeneous compartments for the 3 coordinates. The results revealed statistically significant differences for total color variation (&#8710;E) for the 3 burns group, in comparison to the other types of restoration. When analyzing the specimens of a single type of material, in terms of the interference of the number of burns, the metal-free samples showed no statistically significant differences, whereas the metalloceramic samples showed difference only between those that received 2 and 3 burns. For the total variation of coordinates L*, a*, and b*, both materials showed a variation in those values and in relation to burn cycles. The small statistically significant differences found in some groups are invisible and present no clinical meaning (&#8710;E<3.3). In addition, the multiple burn cycles and accelerated aging did not modify significantly the ceramic’s color stability (&#8710;<1).
37

Efeito do envelhecimento artificial acelerado na estabilidade de cor de cimentos resinosos para cimentação de laminados cerâmicos / Effect of accelerated artificial aging on color stability of resin cements for luting ceramic laminates

Francisca Daniele Jardilino Silame 10 April 2013 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de cimentos resinosos para fixação de restaurações cerâmicas em diferentes espessuras submetidas ao envelhecimento artificial acelerado (EAA). Foram utilizados 60 molares humanos hígidos, cujas porções radiculares foram incluídas em matriz de PVC (15 mm de diâmetro) com resina acrílica e as faces oclusais foram planificadas, 30 em esmalte e 30 até dentina, sendo que 10 dentes de cada substrato foram considerados gruposcontrole para os dentes restaurados. Foram obtidos 40 corpos de prova em cerâmica (IPS e-max Ceram, Ivoclar Vivadent), com 0,5 mm e 1,0 mm, que foram separados aleatoriamente em dois grupos (n=10) segundo o tipo de cimento resinoso dual utilizado para fixação: convencional (Variolink II, Ivoclar/Vivadent) ou auto-adesivo (Rely-X Unicem, 3M ESPE). Além desses, foram obtidos 10 corpos de prova de cada cimento resinoso (0,5mm), considerado grupo-controle para os materiais. Todas as amostras foram mantidas em estufa a 37ºC por 24h, após o qual foram realizadas as leituras de cor iniciais (Vita EasyShade, VITA). Em seguida, foram submetidas ao EAA por 580 horas, após o qual novas leituras de cor foram realizadas. Foi avaliada estabilidade de cor e a luminosidade. Os dados de estabilidade de cor (&Delta;E) e luminosidade (&Delta;L) obtidos foram submetidos a análise estatística (2-way ANOVA, Bonferroni, p<0,05) e a comparação dos materiais com os grupos controles foi realizada utilizando 1-way ANOVA e teste de Tukey (p<0,05). O cimento dual convencional apresentou maior alteração de cor e luminosidade quando sob a restauração de 0,5mm, diferente estatisticamente (p<0,05) de restaurações de 1,0mm. Não houve diferença estatisticamente significante (p>0,05) quando comparados os materiais. Quando analisadas a estabilidade de cor e luminosidade dos grupos com restaurações em relação aos grupos-controle, verificou-se que ambos os cimentos apresentaram maiores alterações, diferente estatisticamente (p<0,05) dos demais grupos, com exceção ao grupo de 0,5mm em relação ao Grupo esmalte quando analisado o cimento dual convencional (p>0,05). Concluiu-se que quanto menor a espessura da restauração, maior a alteração de cor e de luminosidade do cimento dual convencional. As alterações do cimento autoadesivo não dependem da espessura da restauração. / The aim of this study was to evaluate the color stability of resin cements for luting ceramic restorations with different thicknesses submitted to accelerated artificial aging (AAA). Sixty sound human molars had their root portions embedded in PVC rings (15-mm diameter) with acrylic resin. Their occlusal surfaces were flattened according two substrates: 30 surfaces until enamel and 30 until dentin. Then, 10 teeth of each substrate were considered as control groups for restored teeth. Forty specimens of ceramic (IPS e-max Ceram, Ivoclar Vivadent) were obtained with two different thicknesses (0.5 mm and 1.0 mm) and were randomly separated into two groups (n = 10) according to the type of the Dual resin cement used for luting: conventional (Variolink II, Ivoclar / Vivadent) or self-adhesive (Rely-X Unicem, 3M ESPE). Also, 10 specimens (0.5 mm) of each cement were obtained to be considered as control groups for materials. All specimens were stored at 37º C for 24 hours, and initial color readings (Vita Easyshade, VITA) were performed. Then, they were submitted to AAA for 580 hours, and final color readings were taken. Color stability and brightness were evaluated. Data of color stability (&Delta;E) and brightness (&Delta;L) were statistically analyzed (2- way ANOVA, Bonferroni, p<0.05) and the comparison of materials with control groups was performed using one-way ANOVA and Tukeys test (p<0.05). The conventional dual cement showed the greatest change in color and brightness when under restorations of 0.5 mm, statistically different (p<0.05) to restorations of 1.0 mm. There was no statistically significant difference (p>0.05) when comparing materials. When analyzing the color stability and brightness of restorations groups compared to control groups, both cements showed greater changes, statistically different (p<0.05), than other groups, except for the group of 0.5 mm in relation to enamel group when the dual conventional cement was analyzed (p>0.05). It was concluded that the smaller the thickness of the restoration, the greater the color and brightness changes of the dual conventional cement. Changes of the self-adhesive cement do not depend on the thickness of the restoration.
38

"Avaliação da estabilidade de cor da esclera em prótese ocular" / Evaluation of the scleral color stability of ocular prosthesis

Kawabata, Simone Cristina 10 May 2006 (has links)
Baseados no fato de que o corpo escleral sofre alterações progressivas de sua cor no decorrer do tempo, e também pela ausência na literatura específica de trabalhos experimentais relacionados com estas alterações, o presente trabalho tem por objetivo, verificar o desempenho de resinas para esclera e de três tipos de pigmentos neste processo. Os pigmentos utilizados para este fim foram: lápis aquarelável, acrílico termo-polimerizante colorido e pigmento cerâmico; nas cores azul, amarelo e vermelho. Para a realização do experimento, foram confeccionados 100 corpos de prova, sendo 50 de resina para esclera no1e os outros 50 de resina para esclera no2. Cada grupo foi subdividido em 10 subgrupos, com 5 unidades cada, separados em quatro categorias: A, B ,C e E. O grupo A foi caracterizado com lápis aquarelável, o B com resina termo-polimerizável colorida, o C com pigmento cerâmico e o E não recebeu caracterização. Todos os grupos foram recobertos por uma camada de resina incolor. Inicialmente, todos os corpos de prova foram submetidos à análise em um espectrofotômetro acoplado a um sistema de colorimetria. A leitura inicial foi considerada como padrão, sendo as demais, efetuadas a cada 24 horas, até um total de 144 horas intercaladas com ensaios de envelhecimento acelerado por radiação UVA. Os dados colorimétricos, obtidos através das curvas de reflexão de cada amostra, foram utilizados para o cálculo das diferenças de cor. Após o tratamento estatístico dos dados obtidos, foi possível concluir que o lápis aquarelável, nas cores amarela e vermelha e o pigmento cerâmico vermelho, apresentaram uma estabilidade de cor clinicamente aceitável durante todo o tempo experimental. Das duas resinas para esclera avaliadas, a de no2 apresentou melhor estabilidade de cor. / Based on the fact that the sclera of ocular prosthesis presents progressive color alterations with time and due to lack of experimental studies on this topic, the purpose of this study was to evaluate the performance of two types of resins combined with three different kinds of pigments. The pigments used herein were: watercolour pencils, heat-polymerized acrylic resin and ceramic pigment on the colors blue, yellow and red. A total of one-hundred specimens were prepared, among which 50 were made by resin no 1 and the remaining 50 were made by resin no 2. Each group of 50 samples were divided in 10 subgroups containing 5 specimens each, and were separated in four categories: A, B, C and E. Group A was colored with watercolour pencils, while in group B it was used heat-polymerized acrylic resin and in group C, it was used ceramic pigment. Group E was not pigmented. After pigmentation, all specimens received a transparent heat-cured resin layer. At time point zero, all specimens were assessed by a spectrophotometer connected to a colorimeter system, and the initial data were used as the standard value. Immediately after the initial assessment, all samples were kept in a UVA irradiation chamber. The following data were taken after every 24 hours until completion of 144 hours. All colorimetric data were obtained by the reflection curves of each sample and used to calculate the color difference rate. After statistical analysis, it was concluded that the samples colored with watercolour pencil in yellow and red as well as the ceramic pigment in red showed color stability clinically acceptable during the whole experimental period. Between the two types of resin used herein, the resin no 2 showed better color stability.
39

Efeito da escovação e do envelhecimento artificial acelerado sobre a alteração superficial de materiais restauradores estéticos / Effect of simulated toothbrushing and accelerated artificial aging on surface degradation of aesthetic restorative materials

Roselino, Lourenço de Moraes Rego 11 April 2012 (has links)
O objetivo desse estudo foi avaliar sistematicamente o efeito da escovação simulada e do envelhecimento artificial acelerado (EAA) sobre estabilidade de cor e rugosidade de superfície de compósitos odontológicos de nanopartículas (Z350 - 3M ESPE) e híbrido (Tetric N-Ceram - Ivoclar Vivadent). Foram confeccionados 24 corpos-de-prova (12mm de diâmetro X 2mm de espessura) para cada compósito e uma cerâmica de revestimento (IPS e.max Ceram - Ivoclar Vivadent) como controle. Após sua confecção, os corpos-de-prova foram polidos com lixas d&lsquo;água em abrasividades decrescentes (compósitos = 600, 1200 e 2000 e cerâmica = 100, 320, 1200 e 2000). Em seguida, foram realizadas leituras iniciais de cor (Espectrofotômetro PCB 6807) e rugosidade de superfície (Rugosímetro Surfcorder SE 1700 - Kosakalab). As amostras foram separadas em 3 grupos (n=8), segundo o tratamento a que foram submetidas: Grupo 1: EAA; Grupo 2: escovação mecânica com dentifrício RDA* 68 (Colgate); e Grupo 3: escovação mecânica com dentifrício RDA* 180 (Colgate Total Plus Whitening). Após 480 horas de EAA e em intervalos de 41 minutos de escovação (=14.600 ciclos) até 205 minutos novas leituras de cor e rugosidade de superfície foram realizadas. Amostras inicialmente submetidas a EAA (n=4) receberam escovação mecânica com dentifrício RDA* 68 e 180, conforme metodologia descrita anteriormente e novas leituras de cor e rugosidade foram obtidas. Os dados (antes e após os testes) foram analisados estatisticamente (2-way ANOVA análises repetidas, Bonferroni, p<0,05) e verificou-se que houve maior alteração de cor dos compósitos quando submetidos a EAA com diferença estatisticamente significante (p<0,05) em relação à escovação mecânica. Não houve diferença estatisticamente significante (p>0,05) na estabilidade de cor dos materiais quando comparadas as abrasividades dos dentifrícios, porém esse fator foi significante para a alteração de rugosidade de superfície (p<0,05), sendo maior quando os materiais foram escovados com RDA* 180. Quanto ao tempo de escovação, não houve diferença estatisticamente significante (p>0,05) para a alteração de cor e de rugosidade de superfície dos materiais, o mesmo ocorrendo para amostras escovadas após EAA. Conclui-se que o EAA interfere na estabilidade de cor e a escovação simulada nas alterações de rugosidade de superfície dos compósitos, independente do tempo de utilização do dentifrício, sendo maior para dentifrícios mais abrasivos. Além disso, a abrasividade e o tempo de utilização do dentifrício não alteram a capacidade de remoção do manchamento e a rugosidade de superfície de compósitos. / The purpose of this study was to evaluate the effect of simulated toothbrushing and accelerated artificial aging (AAA) on color stability and surface roughness of nanofill (Z350 - 3M ESPE) and hybrid (Tetric N-Ceram - Ivoclar Vivadent) composites. Twenty-four diskshaped specimens (12mm in diameter X 2 mm thick) were made for each composite and one feldspatic ceramic (IPS e.max Ceram - Ivoclar Vivadent) as a control. The specimens were polished with decreasing abrasiveness sandpapers (composites = 600, 1200, 2000 and ceramic = 100, 320, 1200, 2000). Then, initial readings were taken on color (Spectrophotometer PCB 6807) and surface roughness (Rugosimeter Surfcorder SE 1700 - Kosakalab). The samples were separated in 3 groups (n=8) according to the submitted treatments: Group 1: AAA; Group 2: mechanical brushing with dentifrice RDA* 68 (Colgate); and Group 3: mechanical brushing with dentifrice RDA* 180 (Colgate Total Plus Whitening). New readings on color and surface roughness were taken after 480 hours of AAA and in intervals of 41 minutes of brushing (=14.600 cycles) until 205 minutes. The samples initially submitted to AAA (n=4) received mechanical brushing with dentifrice RDA* 68 and 180, according to previously described methodology and new readings on color and roughness were taken. Data (before and after tests) were statistically analyzed (2- way ANOVA repeated measures, Bonferroni, p<0,05) and it was observed a higher composite color alteration compared with mechanical brushing when submitted to AAA with a statistically significant difference (p<0,05) between them. There was no statistically significant difference (p>0,05) on color stability of materials when the dentifrices abrasiveness were compared, but it was significant for surface roughness degradation (p<0,05), higher when materials were brushed with RDA* 180. Regarding time brushing, there was no statistically significant difference (p>0,05) for color alteration and roughness surface of materials and the same occurred for samples brushed after AAA. It was concluded that AAA interferes on color stability and the simulated brushing on surface roughness degradation of composites regardless the time of used dentifrice, but it was higher for more abrasive dentifrices. Moreover, abrasiveness and time of used dentifrice do not alter the capacity of staining removal and the surface roughness of composites.
40

EFEITO DO ACABAMENTO DE SUPERFÍCIE NA ESTABILIDADE DE COR DE RESINAS PARA PROVISÓRIO SUBMETIDAS A DESAFIO CORANTE / EFFECT OF SURFACE FINISHING ON COLOR STABILITY OF RESINS FOR PROVISIONALS SUBMITTED TO STAINING CHALLENGE

Garlet, Katia 25 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to investigate the effect of surface finishing on the color stability of the resins used for provisional restorations when immersed in staining agent in different times (7, 30, and 60 days). Thirty-six disc-shaped specimens (sp) were built up for each type of resin: Duralay (polymethylmethacrylate), Trim II (polyethylmethacrylate) and Protemp 4 (bis-acrylic). The sp were prepared using a muffle with the use of a matrix with dimensions of 10x3 mm. Resins were inserted in the muffle, pressed with 1500 kgf and sp were removed after 15 min. The sp were randomly divided into 2 groups: one was finished with 150-grit sandpaper (rough group) and the other with 150 to 1200-grit sandpapers sequence (polished group). These groups were subdivided into two types of immersion: red wine and saliva (control). Specimens from the wine group were immersed 10 minutes per day and were maintained in saliva along the remained period. Specimens from control group were kept in saliva which was changed every 3 days. The color change (ΔE) was measured with the spectrophotometer SP60 using the CIE L*a*b* system. Data were statistically analyzed by ANOVA and Tukey test (5%). The effect of surface, material and time was statistically significant in red wine (p <0.05). The methylmethacrylate-based resin was superior to the other materials in both storage media, in all periods and in polished and rough surfaces. / O objetivo deste trabalho foi investigar o efeito do acabamento de superfície na estabilidade de cor das resinas utilizadas para confecção de restaurações provisórias submetidas a desafio corante em períodos distintos (7, 30 e 60 dias). Foram confeccionados 36 corpos de prova (cps) em forma de disco para cada tipo de resina: Duralay (polimetilmetacrilato), Trim II (polietilmetacrilato) e Protemp 4 (bis-acril). Os cps foram confeccionados em mufla através de uma matriz com dimensões de 10x3 mm. As resinas foram inseridas na mufla, prensadas com 1500 kgf e os cps removidos após 15 min. Os cps foram aleatoriamente divididos em 2 grupos, sendo que um recebeu acabamento de superfície com lixa d água granulação 150 (grupo rugoso) e o outro acabamento com sequência de lixas de 150 a 1200 (grupo polido). Esses grupos foram subdivididos em dois tipos de imersão: vinho tinto e saliva (controle). Os cps do grupo vinho receberam imersões diárias de 10 minutos e no restante do tempo eram mantidos em saliva. Os cps do grupo controle permaneceram em saliva, que era renovada a cada 3 dias. A alteração de cor (ΔE*) foi medida pelo espectrofotômetro SP60 utilizando o sistema CIE L*a*b*. Os dados foram analisados estatisticamente através de Análise de Variância com fator vinculado e Teste de Tukey (5%). O efeito da superfície, material e tempo foi estatisticamente significante em vinho (p<0,05). A resina à base de metilmetacrilato mostrou superioridade nos dois meios de imersão, em todos os tempos e nas superfícies polida e rugosa.

Page generated in 0.0571 seconds