• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Färgstabilitet hos protesbasmaterial beroende på framställningsteknik efter borstning, åldring, kaffeförvaring och rengöring. / Color stability of denture base materials depending on production technique after brushing, aging, coffee storage and cleaning

Chojnacka, Ewa, Holmgren, Amanda January 2023 (has links)
Syfte: Syftet med föreliggande studie är att undersöka färgstabiliteten hos konventionellt varmpolymeriserat, fräst och 3D-printat material för protesbaser efter borstning, termocykling, kaffeförvaring och rengöring. Material och metod: Tio provkroppar av ett material per teknik framställdes; konventionell (ProBase Hot, Ivoclar), CAD/CAM subtraktiv (Ivotion Base, Ivoclar) och additiv teknik (Lucitone Digital Print, Dentsply). Diskformade provkroppar slipades till 3mm x 10mm och polerades. Färgkoordinaterna L*a*b* mättes genom spektrofotometri före och efter alla behandlingarna. Provkropparna borstades i 50 minuter, termocyklades i 10 000 cykler, förvarades 12 dagar i kaffe och därefter rengjordes de med alkalisk peroxid. Medelvärdet av L*a*b* registrerades och färgskillnaderna (ΔEab, NBS) beräknades. Resultatet registrerades i SPSS och analyserades med One-way ANOVA, Tukey’s test med signifikansnivån α=0,05. Resultat: I jämförelse mellan materialgrupperna hade 3D-printat högst medelvärde i färgskillnad (ΔEab 1,17) följt av fräst (ΔEab 1,14) och varmpolymeriserat (ΔEab 0,91). Alla värden var under MT, vilket innebär ‘’mycket god färgmatchning’’. Ingen signifikant skillnad fanns mellan materialgrupperna. Av behandlingarna gav termocykling störst missfärgning (ΔEab 1,30), följt av kaffeförvaring (ΔEab 1,15), rengöring (ΔEab 1,04) och borstning (ΔEab 0,81). Signifikanta skillnader för färgskillnaden, ΔEab, observerades: varmpolymeriserat efter borstning hade en mindre färgskillnad jämfört med fräst efter termocykling (p=0,003), och fräst efter borstning hade en mindre färgskillnad jämfört med fräst efter termocykling (p=0,002) Slutsats: Färgstabiliteten hos protesbasmaterial är beroende av material och framställningsteknik. 3D-printat material har lägst färgstabillitet följt av fräst och konventionellt varmpolymeriserat. Trots detta är medelvärdena för färgskillnaden inom gränsvärdena för en mycket god färgmatchning för alla material. Alla material hade acceptabel färgstabilitet efter borstning, termocykling, kaffeförvaring och rengöring. / Purpose: This study investigated color stability of conventional heat polymerized, milled and 3D-printed denture materials after brushing, thermocycling, coffee storage and cleansing. Material and method: Ten specimens (3mm x 10mm) of each material were prepared and polished; conventional (ProBase Hot, Ivoclar), milled (Ivotion Base, Ivoclar) and 3D-printed (Lucitone Digital Print, Dentsply). L*a*b* were measured before and after treatments. The specimens were brushed, thermocycled, stored in coffee, and cleansed to simulate one years usage. Mean value of L*a*b* and color differences (ΔEab, NBS) were calculated. Results were recorded in SPSS with One-way ANOVA, Tukey's test (α=0.05). Results: Between the material groups, 3D-printed had the highest mean value in color difference (ΔEab 1.17), then milled (ΔEab 1.14) and heat polymerized (ΔEab 0.91). All values were below MT, meaning “very good match”. No significant difference were found between the materials. Of the treatments, thermocycling showed the greatest discoloration (ΔEab 1.30), followed by coffee storage (ΔEab 1.15), cleaning (ΔEab 1.04) and brushing (ΔEab 0.81). Significant differences for the color difference, ΔEab, were observed: heat polymerized after brushing had a smaller color difference than milled after thermocycling (p=0.003), and milled after brushing had a smaller color difference than milled after thermocycling (p=0.002) Conclusion: The color stability of denture base materials is dependent on the material and manufacturing technique. 3D-printed material has the lowest color stability followed by milled and conventional heat polymerized. Despite this, the mean color differences are within the limits of a very good color match. All materials had acceptable color stability after brushing, thermocycling, coffee storage and cleaning.
2

Färgstabilitet hos manuellt färginfiltrerad högtranslucent zirkonia efter upprepade bränningar / Color stability in manually color infiltrated translucent zirconia after repeated firings

Follin, Lydia, Hofmann, Christian January 2021 (has links)
Syfte: Syftet med föreliggande studie är att undersöka färgstabiliteten hos manuellt färginfiltrerad högtranslucent zirkonia efter upprepade bränningar.   Material och metod: Fem provkroppar av respektive fabrikat; Prettau® Zirconia (PZ) och M+W Zircon HT (MW) kapades fram ur ofärgade zirkonia-diskar. Provkropparna färgades in manuellt med färgen A3 och torkades därefter under en infraröd lampa. Provkropparna sintrades enligt fabrikanternas anvisningar och en första färgmätning utfördes med en spektrofotometer (VITA Easyshade Advance 4.0) mot en matt grå bakgrund. Där efter utfördes bränningar av provkropparna i fyra cykler. Efter varje cykel utfördes färgmätningar.Medelvärdena för L*a*b*c*h* registrerades. Formlerna CIE76 (∆E*ab) och CIEDE2000 (∆E*00) användes för att räkna ut färgskillnader efter bränncyklerna. Värdena registrerades i SPSS och analyserades med One-way ANOVA, Tukey’s test med en signifikansnivå på α=0,05.   Resultat: Statistiskt signifikanta skillnader (p<0,05) i färgförändring hittades både inom och mellan de båda grupperna (MW och PZ). Färgskillnaderna som uppmättes befann sig inom ramen för vad som anses som en acceptabel (∆E*ab≤2,7 och ∆E*00≤1,8) eller mycket god färgmatchning (∆E*ab≤1,2 och ∆E*00≤0,8).   Slutsats: Inom ramen för studiens begränsningar kan följande slutsatser dras: Upprepade bränningar påverkar färgen hos manuellt färginfiltrerad högtranslucent zirkonia. De färgförändringar som sker är inom ramen för vad som räknas som en ”acceptabel färgmatchning” eller ”mycket god färgmatchning” enligt aktuella gränsvärden. Färgförändringarna som sker är inte iögonfallande och har ringa betydelse kliniskt. Färgen och färgskillnader hos manuellt färginfiltrerad högtranslucent zirkonia är beroende av fabrikat. / Purpose: The purpose of this study is to investigate color stability in manually color infiltrated high translucent zirconia after repeated firings. Material and methods: Five specimens of each manufacturer; Prettau® Zirconia (PZ) and M+W Zircon HT (MW) were cut from uncolored zirconia discs. The specimens were manually colored with shade A3, and dried. The specimens were sintered and a first color measurement was performed with a spectrophotometer (VITA Easyshade Advance 4.0) against a matte gray background. Firings of the specimens were performed in four cycles. After each cycle, color measurements were performed. The mean values for L*a*b*c*h* ​​were registered. The formulas CIE76 (∆E*ab) and CIEDE2000 (∆E*00) were used to calculate color differences after firing cycles. The values were registered and analyzed with One-way ANOVA, Tukey's test with a level of significance at α=0.05.  Results: Statistically significant color differences (p<0.05) were found within and between groups (PZ and MW). The color differences measured were within the range of what is considered an acceptable match (∆E*ab≤2.7 and ∆E*00≤1.8) or a perfect match (∆E*ab≤1.2 and ∆E*00≤0.8).   Conclusion: Within the limitations of this study, the following conclusions can be drawn: Repeated firings affect the color in manually color infiltrated high translucent zirconia. The color changes that occur are within the range of what is considered an “acceptable match” or “perfect match” according to current thresholds. The color changes are not conspicuous and of little importance clinically. The color and color differences in manually color infiltrated high translucent zirconia are dependent on the brand.

Page generated in 0.1143 seconds