• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1288
  • 725
  • 176
  • 107
  • 100
  • 85
  • 83
  • 36
  • 19
  • 16
  • 13
  • 13
  • 13
  • 13
  • 13
  • Tagged with
  • 3144
  • 498
  • 269
  • 263
  • 178
  • 176
  • 162
  • 155
  • 154
  • 139
  • 127
  • 127
  • 109
  • 108
  • 108
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
801

A video image interface

Velez, Ricardo Eugenio January 1982 (has links)
Thesis (M.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science, 1982. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING. / Bibliography: leaf 56. / by Ricardo Eugenio Velez. / M.S.
802

Beef muscle color as affected by nutritional regime and vacuum packaging

Harrison, Allen Randall January 2011 (has links)
Typescript. / Digitized by Kansas Correctional Industries
803

Study of the optical absorption and dichroism of color centers in gamma-irradiated LiF:Mg

Jen, Luke Chen-Yuan January 2011 (has links)
Digitized by Kansas Correctional Industries
804

Lamps for lighting people

Chao, Anne Rong January 2011 (has links)
Typescript (photocopy). / Digitized by Kansas Correctional Industries
805

How to get changing patterns on a textile surface by using thermo chromic pigments and an inherently conductive polymer

Maleki, Laleh January 2013 (has links)
With regard to the recent interests in smart textiles,this research activity has been conducted with the aim of producing a pattern changing design on textiles. In order to fulfill the demands of such dynamic patterns a combinationof conductive polymer and thermochromic pigments wereused. The textile substrate was coated by conductive polymer dispersion(PEDOT:PSS) and it was followed with printing thermochromic pigments on the surface of coating.The driving force of such thermochromic reaction has to be provided by the heat generated from conductive layer dueto the current of electricity passing through the conductivelayer. These experiments were continued by changing thecoating recipe in order to achieve the highest possible electrical resistance,which leads to the best initiation ofthermochromic reactions. / Program: Master programme in Textile Technology
806

House design.

Brosk, Jeffrey Owen January 1976 (has links)
Thesis. 1976. M.Arch.--Massachusetts Institute of Technology. Dept. of Architecture. / Microfiche copy available in Archives and Rotch. / Bibliography: leaves 41-42. / M.Arch.
807

Caracterização da cor estrutural no élitro do besouro Chrysina chrysargyrea (Coleoptera) / Caracterization of the structural color in the elytva of the beette Chrysina Chrysavgyrea (Coleoptera)

Garces, Victor Hugo Manotas 25 April 2013 (has links)
Neste trabalho foram estudadas instabilidades magnetohidrodinâmicas (MHD) utilizando um novo sistema bolométrico que foi instalado no tokamak TCABR para medidas da evolução temporal da potencia irradiada. Este novo sistema conta com 24 cordas verticais, capazes de mapear toda uma seção poloidal da coluna de plasma com resolução espacial de aproximadamente 2 cm e uma resolução temporal de 20 _s. Como se sabe, as instabilidades MHD degradam o confinamento do plasma e modificam a topologia das superfícies magnéticas, causando a perda da energia do plasma. Por conta disso, compreender essas instabilidades é fundamental para o sucesso dos futuros reatores de fusão nuclear. As perturbações (oscilações) causadas pelas instabilidades MHD modulam diversos parâmetros macroscópicos do plasma como a densidade, a temperatura e a potencia irradiada. Então, utilizando o diagnostico bolométrico, _e possível medir as oscilações no perfil de potencia irradiada e, a partir deles, extrair informações importantes para determinar a origem e as características de tais instabilidades. No tokamak TCABR, as instabilidades foram caracterizadas através da analise espectral dos 24 sinais provenientes do novo sistema bolométrico. Para auxiliar a caracterização das instabilidades, um programa foi desenvolvido em Matlab para simular as medidas das perturbações no perfil de potencia irradiada. Através do mesmo procedimento de analise espectral, os resultados simulados foram comparados aos experimentais de forma que os parâmetros simulados, como largura e posição das ilhas magnéticas, fossem ajustados aos experimentais. Através dessa metodologia de analise, que combina simulação e experimento, foi possível caracterizar diversas instabilidades como o precursor dos dentes de serra e ilhas magnéticas de modos m = 2 e m = 3. / In this dissertation, magnetohydrodynamic (MHD) instabilities were investigated using a new bolometric system that was installed in the TCABR tokamak for radiation power measurements. This diagnostic is composed by 24 vertical chords that provide a full view of the poloidal cross section of the plasma column and provides spatial and temporal proles with approximately 2 cm space and 20 s time resolution. As it is well known, theMHD instabilities degrade the plasma connement and modify the magnetic topology, leading to energy loss from the plasma. Therefore, the understanding of these instabilities is essential for the success of the controlled thermonuclear fusion reactors. The MHD instabilities also cause perturbations (oscillations) in various macroscopic parameters, such as plasma density, temperature, and radiated power. Therefore, the oscillations in the radiated power prole measured by the bolometric diagnostic system provide a possibility to investigate the origin and features of the instabilities. In the TCABR tokamak, the instabilities were characterized by spectral analysis of the 24 vertical chords of the bolometric signals. In addition, a Matlab program was developed to simulate the integral characteristic of the oscillations in the radiated power measured by the bolometric system. The spectral analysis of the simulated signals is then compared with the spectral analysis of the bolometric signals. The simulated parameters, island width and radial position, were then adjusted to t the experimental spectrum results. Using this method of analysis, which combines experiment and simulation, it was possible to characterize various instabilities, such as sawtooth precursor and m = 2 and m = 3 magnetic islands.
808

Estudo clínico randomizado, duplo-cego da percepção da cor e satisfação e sensibilidade em pacientes submetidos a clareamento dental / Double-blind, randomized, clinical trial of color perception and satisfaction in patients undergoing dental bleaching

Nishida, Alexander Cassandri 20 September 2016 (has links)
O clareamento dentário é a maneira mais conservadora e barata de melhorar a satisfação dos pacientes com o seu sorriso. Entretanto existem poucos estudos que correlacionam a eficácia clareadora com a satisfação dos pacientes e a maneira como eles percebem a mudança das cores. OBJETIVO: Investigar a relação entre mudança de cor e satisfação e a percepção da mudança de cor pelos pacientes e operador treinado comparado a um método instrumental. MATERIAIS E MÉTODOS: Uma pesquisa clínica randomizada duplo-cega foi conduzida com 100 pacientes que atendiam os critérios de inclusão e exclusão. Eles foram divididos em 5 grupos randomizados: Peróxido de hidrogênio 4%, peróxido de carbamida 15%, peróxido de carbamida 16%, Peróxido de carbamida 16% experimental e placebo. Foi tomada a cor base dos dentes através de tomadas objetivas com Vita Easyshade e subjetivas com a escala Vita BleachGuide 3D. Eles foram submetidos à terapia clareadora recebendo uma seringa de gel clareador por semana durante 3 semanas e preencheram avaliação sobre sua sensibilidade e avaliações sobre satisfação e percepção de mudança de cor. Foi um total de 11 visitas por paciente: entrevista inicial e triagem, moldagem e profilaxia, tomada de cor e entrega de clareador, controles de 7, 14, 21, 30, 60, 90, 120 e 180 dias. Nos retornos todas as etapas de tomada e controle de cor pelo paciente e pelo mesmo operador treinado, objetiva e subjetiva foram repetidas. RESULTADOS maiores valores de ?E* na sem 1, ANOVA mostrou que eles foram diferentes entre si (P=0.001), valor que não se repete a partir da segunda semana na análise entre os grupo (P=0.275). Maiores ?E* foram os géis à base de peróxido de carbamida (PC15, PC16 e PC16EX). ?E* Final foi maior no grupo PC15, PC16 e PC16EX e esses 3 grupos foram estatísticamente semelhantes. Os menores valores foram para o grupo placebo que não foi semelhante a nenhum outro grupo e nem entre os tempos. A análise de variância entre os 5 grupos mostrou diferenças para percepção cega (p=0.001), percepção orientada (p=0.001), e expectativa (p=0.603. Fica claro que a satisfação do paciente é crescente em todos os grupos da primeira a terceira semana de terapia. A ordem de satisfação dos pacientes foi PC15, PC16EX, PC16, PH4 e PLAC. No último período representado, terceira semana ao fim do acompanhamento de 6 meses, verificamos que a satisfação diminui no período pós-terapia, principalmente para o grupo PLAC e para o grupo PC16EX. Mesmo o grupo PLAC (que representa o placebo) também teve satisfação crescente. No arco inferior os maiores resultados para sensibilidade ficaram também com PH4, PC15 e PC16..CONCLUSÕES: Os clareadores baseados em peróxido de carbamida tiverem as maiores variações de cor, sendo os mais efetivos. Em comparação ao paciente, o operador treinado tem uma capacidade de avaliação de cor mais próxima dos valores aferidos instrumentalmente. A satisfação do paciente aumenta com todos os grupos, inclusive o placebo, porém declina no período pós terapia. Os pacientes tendem a enxergar os dentes mais escuros do que realmente são e criam expectativas por cores mais claras. Todos os grupos causaram sensibilidade, inclusive o placebo, semelhantes para maxila e mandíbula. / Tooth whitening is the most conservative and inexpensive way to improve patient satisfaction with your smile. However there are few studies that correlate the whitening efficacy with patient satisfaction and how they perceive the change of colors. To investigate the relationship between color change and satisfaction and perception of color change by patients and trained operator compared to an instrumental method. MATERIALS AND METHODS: A double-blind randomized clinical trial was conducted with 100 patients who met the inclusion and exclusion criteria. They were divided into five randomized groups: Hydrogen peroxide 4%, 15% carbamide peroxide, 16% carbamide peroxide, 16% carbamide experimental and placebo. It was made the base color of the teeth through objective taken with Vita Easyshade and subjective with the Vita BleachGuide 3D scale. They underwent therapy Clarifying getting a whitening gel syringe per week for 3 weeks and completed evaluation of its sensitivity and reviews of satisfaction and perception of color change. There were a total of 11 visits per patient: initial interview and sorting, forming and prophylaxis, making color and delivery bleaching 7 controls 14, 21, 30, 60, 90, 120 and 180 days. In returns all steps taken and color control by the patient and by the same trained operator, objective and subjective were repeated. RESULTS larger ?E * values in no 1, ANOVA showed that they were different (P = 0.001), a figure that is not repeated from the second week on the analysis of the group (P = 0.275). Larger ?E * the gels were carbamide peroxide-based (PC15, PC16 and PC16EX). ?E * Final was higher in the group PC15, PC16 and PC16EX and these 3 groups were statistically similar. The lowest values were for the placebo group was not similar to any other group or between the times. Analysis of variance among the five groups showed differences to blind perception (p = 0.001), oriented perception (p = 0.001) and expectation (p = 0.603. It is clear that patient satisfaction is increasing in all of the first groups third week of therapy. the order of patient satisfaction was PC15, PC16EX, PC16, PH4 and PLAC. in the latter represented period, the third week after the 6-month follow-up, we found that satisfaction decreases in the post therapy period, mainly for PLAC group and the group PC16EX Even the PLAC group (representing placebo) also had increasing satisfaction in the lower arch greater results for sensitivity were also PH4, PC15 and PC16..CONCLUSÕES: carbamide peroxide have the greater color variations, the most effective being. compared to the patient, the trained operator has a capacity assessment of the closest color of the measured values instrumentally. patient satisfaction increases with all the groups, including the placebo, but declines in the period post therapy. Patients tend to see the darker teeth than they really are and create expectations for lighter colors. All groups sensitivity caused, including placebo, similar to maxilla and mandible.
809

Avaliação clínica de diferentes técnicas de clareamento de dentes polpados quanto à efetividade durante 12 meses / Clinical evaluation of effectiveness for different techniques of extrinsic bleaching

Azevedo, Juliana Felippi David e Goés de 30 September 2009 (has links)
Objetivos: Este estudo in vivo avaliou comparativamente diferentes técnicas de clareamento de dentes polpados, quanto ao grau de mudança de cor e estabilidade do tratamento num período de doze meses, sensibilidade dentinária e o condicionamento ácido prévio ao clareamento. Métodos: Quarenta e cinco voluntários foram selecionados, de acordo com os critérios de inclusão e exclusão, e divididos aleatoriamente em 5 grupos (n=15). No clareamento em consultório, apenas na hemi-arcada direita (inferior e superior), o gel clareador foi ativado com uma fonte de luz híbrida enquanto no outro lado o gel não foi ativado, assim um mesmo voluntário participou de dois grupos. Além disso, um primeiro pré-molar superior direito ou esquerdo foi condicionado previamente ao clareamento com ácido fosfórico a 37% durante 15s. G1- Lase Peroxide (DMC Equipamentos), a base de peróxido de hidrogênio (PH) a 35% + duas ativações do gel com luz híbrida (LED e Laser de Diodo) (Whitening Lase II DMC Equipamentos) por três minutos e intervalo de 1min; em três aplicações; G2- Lase Peroxide em três aplicações de 15min e intervalos de 15mim; G3 - Opalescence Xtra Boost (Ultradent), a base de PH a 38% + duas ativações do gel com luz híbrida por três minutos e intervalo de 1min; em três aplicações; G4- Opalescence Xtra Boost em três aplicações de 15min e intervalos de 15mim; G5 - Opalescence PF (Ultradent), a base de peróxido de carbamida (PC) a 15%, 2 horas diárias por 10 dias. A avaliação da cor quantitativamente foi realizada com o espectofotômetro Vita EasyShade (Vita), antes do clareamento e após 24horas, 1 semana, 6 e 12 meses. A diferença de cor (_E) foi mensurada através do programa CIELab. A sensibilidade dentinária foi avaliada por meio do questionário VAS antes, imediatamente após o clareamento, 24 horas e uma semana. Resultados: A análise estatística não revelou nenhuma diferença estatística significante entre os grupos com e sem ativação do gel com luz híbrida. Diferença estatística foi observada entre os resultados após 24h, 1 semana e 1, 6 e 12 meses para todos os grupos experimentais. O clareamento em consultório utilizando o Lase Peroxide mostrou um aumento significante na sensibilidade quando comparado com o clareamento caseiro. O Lase Peroxida utilizado com luz híbrida e condicionamento prévio do esmalte demonstrou aumento significante da alteração de cor. Conclusão: Pode-se concluir que todas as técnicas e agentes clareadores usados são efetivos no clareamento dental. O uso de condicionamento ácido prévio ao clareamento aumenta o grau clareamento dos dentes. / Objectives: This study was evaluated color change and stability and tooth sensitivity in patients submitted to different bleaching techniques. Methods: Forty five patients were selected according to inclusion/exclusion criteria and divided in five groups (n=15). A half-mouth design was conducted to compare two in-office bleaching techniques with the same product and the effect of acid condition before treatment. G1: 35% hydrogen peroxide (HP) (Lase Peroxide, DMC Equipments) + hybrid light (LED + Diode Laser) Whitening Lase II (DMC equipments); G2: 35%HP; G3: 38%HP, X-tra Boost (Ultradent) + hybrid light; G4: 38%HP and G5: 20% Carbamide Peroxide (PC), Opalescence PF (Ultradent). For G1 and G2, PH was applied on the enamel surface for three consecutive times and activated by hybrid light during 6 min; G2 and G4, PH was applied on the enamel surface for three consecutive times during 15min and interval of 15min; G5, 15% PC for 2 hours daily during 10 days at home. The spectrophotometer VITA Easyshade (VITA) was used for color change, before the treatment and 24h, 1 week, 1, 6 and 12 months after. Color differences (_E) were assessed by means of the CIELab Program. VAS questioner was used for sensitivity tooth before the treatment and immediately, 24h and 1 week after. Results: The statistical analysis did not reveal any significant difference between activated or not by hybrid light. Statistical difference was observed between the results after 24h, 1 week and 1, 6 and 12 months, for both experimental groups. In-office bleaching with Lase Peroxide showed significant increase tooth sensitivity compared to home bleaching. Lase Peroxide with hybrid light and acid condition showed a significant increase in color change. Conclusion: It could be concluded that all the techniques and bleaching agents used are effective for dental bleaching. The use of acid condition before bleaching increase color chance.
810

Avaliação da estabilidade de cor e rugosidade superficial de resinas compostas micro-híbridas, submetidas ao processo de envelhecimento artificial acelerado, em função da fotoativação com lâmpada halógena e LED / Color stability and surface roughness of micro hybrids resins polymerized by LED or halogen light irradiation after accelerated aging.

Malaspina, Odirlei Arruda 14 September 2009 (has links)
O estudo avaliou, in vitro, as variáveis relacionadas à alteração de cor e à rugosidade superficial das resinas compostas micro-híbridas: Charisma (Heraeus-Kulzer), Filtek Z-250 (3M - Espe), Herculite XRV (Kerr), Opallis (FGM), TPH Spectrum (Dentsply) e W3D (Wilcos), antes e após o envelhecimento artificial acelerado, tendo como fatores de variação duas fontes de luz, lâmpada halógena e LED, com densidades de potência de 300 mW/cm2 ou 600 mW/cm2. Foram confeccionados 240 corpos-de-prova distribuídos em grupos de 10 unidades para cada condição de estudo totalizando 24 grupos constituídos por 4 protocolos de fotoativação para cada marca de resina composta. Estes corpos-de-prova foram armazenados em água deionizada, ao abrigo de luz e a temperatura de 37oC por 1 semana quando então receberam polimento superficial com discos Diamondpro (FGM). Sequencialmente, os mesmos foram submetidos às análises iniciais de rugosidade superficial (rugosímetro Hommle Tester T1000 basic) e de cor (Espectrofotômetro EasyShade). Decorridas 24 horas, os espécimes foram submetidos ao Sistema de Envelhecimento Acelerado para materiais não metálicos C-UV por 384 horas quando então foram novamente realizadas as leituras de rugosidade e cor. Os valores de rugosidade superficial e alteração de cor das resinas compostas, após o processo de envelhecimento acelerado, demonstraram alterações significativas, sendo os valores de E muito superiores ao considerado clinicamente aceitável (E3,3). De forma geral, o efeito exercido pelos protocolos de fotoativação não permitiu distinguir a influência direta das irradiâncias das fontes de luz no comportamento das diferentes resinas compostas, observando-se uma correlação positiva média entre rugosidade superficial e a alteração de cor. / This study aimed to evaluate changes in color and surface roughness, before and after artificial accelerated aging of six micro hybrids composites resins (comparable to Vita shade A2) cured by quartz tungsten halogen (H) or a light emitting diode (L) polymerization unit with 300 mW/cm2 or 600 mW/cm2. Forty disc specimens (7 x 2 mm) were prepared for each composite (Charisma®, Filtek Z-250®, Herculite XRV®, Opallis®, TPH Spectrum®, W3D®), being 10 specimens for each condition (Q 300/600 mW/cm2 or L 300/600 mW/cm2). After cured, each specimen was evaluated by color (Easy Shade® spectrophotometer) according to CIE L*a*b* color scale and by surface roughness (Hommelwerke GmbH ) Ra values before and after submitting to artificial accelerated aging (4 h UV-B/4 h condensing vapor) for 384 hours total. The surface roughness and color change values of composite resins, after the process of accelerated aging, showed significant changes. Also, the values of E after accelerated aging were much higher than the values considered clinically acceptable (E 3.3). In general, the protocols curing effects showed varied influence over different composite resins and a positive correlation between average change in surface roughness and color change after accelerated aging process.

Page generated in 0.0444 seconds