• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 18
  • 18
  • 18
  • 18
  • 14
  • 14
  • 14
  • 14
  • 12
  • 6
  • 4
  • 3
  • 2
  • Tagged with
  • 473
  • 249
  • 127
  • 116
  • 54
  • 54
  • 53
  • 51
  • 51
  • 45
  • 44
  • 40
  • 33
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Valores de referência e confiabilidade de testes clínicos para avaliação funcional lombopélvica / Reference values and reliability for tests of lumbopelvic functional assessment

Isadora Orlando de Oliveira 16 September 2016 (has links)
Introdução: Força, resistência e atividade muscular são uma área importante de pesquisa e avaliação contribuindo para um melhor entendimento de aspectos musculoesqueléticos de mecanismos de dor e lesão. No entanto, a utilização de testes que avaliem a região lombopélvica ainda é controversa, pois apesar de muitos testes clínicos estarem disponíveis na literatura, ainda não estão estabelecidos quais os mais confiáveis na prática clínica. Objetivos: Estabelecer valores de referência, determinar confiabilidade intra e interexaminador e as medidas de erro de um conjunto de testes clínicos que avaliam a região lombopélvica em indivíduos assintomáticos de diferentes gêneros, faixas etárias e níveis de atividade física. Materiais e Métodos: Para os valores de referência, 152 indivíduos (79 homens, 73 mulheres) estratificados por gênero, faixa etária e nível de atividade física realizaram um conjunto de nove testes clínicos: força isométrica máxima de abdutores, extensores, flexores e rotadores laterais de quadril, resistência nas posições de ponte lateral, ponte frontal, flexores e extensores lombares e atividade muscular da região lombopélvica. Para a confiabilidade, 33 indivíduos foram avaliados por dois examinadores em um intervalo de 3 a 7 dias, onde realizaram aleatoriamente o mesmo conjunto de testes. As medidas de confiabilidade foram avaliadas pelo Coeficiente de Correlação Interclasse (CCI2,1) e as medidas de erro definidas pelo Erro Padrão da Medida (EPM) e pela Mínima Mudança Detectável (MMD). Resultados: Foram observadas diferenças significativas (p<0.05) nos testes clínicos para as variáveis: gênero, faixa etária e nível de atividade física e estabelecidos valores de referência para cada grupo. Todos os testes apresentaram valores de confiabilidade excelente com CCI (IC 95%) maior que 0.8 para as confiabilidades intra e interexaminador; os valores da MMD foram superiores à média do EPM em todos os testes. Conclusão: Os resultados do presente estudo apontam valores de referência que contribuem com o estabelecimento de referências para auxiliar na tomada de decisões clínicas. Além disso, este conjunto de 10 testes apresentou confiabilidade intra e interexaminador bem como valores de EPM e MMD, confirmando a possibilidade de seu uso na prática clínica. / Background: The assessment of the lumbopelvic region is useful for many musculoskeletal dysfunctions. Several clinical tests are commonly used to assess this region, however, reference values for clinical assessments and results concerning method, reliability and error measurements of these tests have not been reported. Objectives: To establish reference values and to determine intra and interrater reliability, standard error of measurement (SEM) and minimum detectable change (MDC) of a set of clinical tests used for assessing the lumbopelvic region in asymptomatic volunteers of different gender, age groups and physical activity levels. Methods: For reference values, 152 subjects (79 men, 73 women) divided by gender, age group and physical activity levels, performed nine clinical tests: Maximum voluntary isometric strength of hip abductors, extensors, flexors and lateral rotators, transversus abdominis(TrA) muscle activity (using a Pressure Biofeedback Unit), prone and side bridges, trunk flexor and extensor endurance tests. To measure reliability, 33 individuals performed the same set of tests, in random order within a week period. Intrarater and interrater analysis were assessed using the Intraclass Correlation Coefficient (ICC) and the error measurements were defined by using the SEM and the MDC. Results: Reference values were established for each group and our results showed significant (p<0.05) differences concerning gender, age group and physical activity levels in clinical tests. In general, strength differences were related to gender and physical activity levels and endurance results could be related to interactions between gender, age group and physical activity levels. All tests presented good reliability indices with an ICC (95%CI) higher than 0.8 for the intrarater and interrater reliability; MDC values were greater than mean of SEM in all tests, confirming its usage for clinical practice assessments. Conclusion: Reference values are necessary to help clinicians in the evaluation of subjects and these results can contribute for clinical practice in providing clinical training targets. Also, this set of tests presented good intra and interrater reliability measures of strength, endurance and TrA muscle activity test as well as SEM and MDC values, confirming its use for assessing the lumbopelvic region.
162

Estudo retrospectivo dos achados radiogr?ficos em coluna vertebral de c?es com altera??es na marcha / Retrospective study of radiographic findings in spine of dogs with gait changes

SILVA, Andr? Luiz Blaschikoff da 28 August 2015 (has links)
Submitted by Jorge Silva (jorgelmsilva@ufrrj.br) on 2017-04-26T19:09:52Z No. of bitstreams: 1 2015 - Andr? Luiz Blaschikoff da Silva.pdf: 1045335 bytes, checksum: cb54caf676d135e9a9256f6ecd05072c (MD5) / Made available in DSpace on 2017-04-26T19:09:52Z (GMT). No. of bitstreams: 1 2015 - Andr? Luiz Blaschikoff da Silva.pdf: 1045335 bytes, checksum: cb54caf676d135e9a9256f6ecd05072c (MD5) Previous issue date: 2015-08-28 / CAPES / With the growing of complementary imaging tests, evaluation of patients at the clinic of small animals obtained great progress, given that these media provide better identification of structures and increase accuracy in the diagnosis of diseases of different organ systems. The routine of do radiographs also provides a series of findings without value to the current patient's clinical and in some cases, non-visualization of the primary pathology limitations related to diagnostic method employed. With this work, was made a study investigating possible radiographic findings in patients who have a disability in walking (motor or sensory pathways), whether those findings could explain the clinical conditions of the patients. This kind of study is used in clinical trials, where a small number of individuals are in. Survey was conducted radiographic reports requests related to Spinal dogs, September 2013 to August 2014, at the radiology department of a Veterinary Clinic, located in Rio de Janeiro City, in the West Zone, September 2013 to December 2014 of the Small Animal Veterinary Hospital at the Federal Rural University of Rio de Janeiro (UFRRJ) and from a veterinary radiologist. The assessment covered all reports related to any of the segments of the spine. At the end of the evaluation, we obtained the percentage of pathological changes in radiographs that were described in the reports, in relation to clinical complaints on requests after clinical examination. The reports were about spines of 280 dogs, 148 (52.86%) males and 132 (47.14%) females, with the average age of females was 8.1 years and the males was 7,5 years. Vertebral regions most X-rayed during the period under study were isolated lumbar and thoracic with lumbar and the most frequent alteration was reduction of the intervertebral space, totaling 40.1% of cases in which they had found. The study found that the racial mixture, known as Mixed Breed Dog (MBD), is widespread in the domestic environment in large quantities, and this breed best imaged with 36.79% of the reports. / Com o surgimento dos exames complementares por imagem, a avalia??o dos pacientes na cl?nica m?dica de pequenos animais obteve grande evolu??o, tendo em vista que esses meios proporcionam melhor identifica??o de estruturas e aumentam a acur?cia nos diagn?sticos de afec??es dos diferentes sistemas org?nicos. A rotina de realiza??o de radiografias simples tamb?m propicia a casu?stica de achados sem valor para a atual cl?nica do paciente e, em alguns casos, a n?o visualiza??o da patologia prim?ria por limita??es relacionadas ao m?todo diagn?stico empregado. Com a realiza??o do presente trabalho, foi realizado um estudo de casos, investigando-se os poss?veis achados radiogr?ficos em pacientes que possuem algum tipo de defici?ncia na marcha, (motora ou sensitiva), verificando se tais achados podem justificar os quadros cl?nicos dos pacientes. Este tipo de estudo, ? empregado na ?rea cl?nica, onde um pequeno n?mero de indiv?duos ? inclu?do para avalia??o. Foi realizado levantamento de laudos radiogr?ficos de solicita??es relacionadas ? Coluna Vertebral de c?es, de Setembro de 2013 a Agosto de 2014, do setor de radiologia de uma Cl?nica Veterin?ria, localizada na Zona Oeste da Cidade do Rio de Janeiro, de Setembro de 2013 a Dezembro de 2014 do Hospital Veterin?rio de Pequenos Animais da Universidade Federal Rural do Rio de Janeiro (UFRRJ) e de veterin?rio particular. A avalia??o abrangeu todos os laudos relacionados a quaisquer uns dos segmentos da coluna vertebral. Ao final da avalia??o, obteve-se o percentual das altera??es patol?gicas visualizadas nas radiografias que foram descritas nos laudos, em rela??o ?s queixas cl?nicas nas solicita??es ap?s exame cl?nico. Os laudos radiogr?ficos eram de colunas vertebrais de 280 c?es, sendo 148 (52,86%) machos e 132 (47,14%), f?meas, sendo que a m?dia de idade das f?meas foi de 8,1 anos e dos machos foi de 7,5 anos. As regi?es vertebrais mais radiografadas durante o per?odo em estudo foram a Lombar isolada e Tor?cica com lombar e a altera??o mais frequente foi Redu??o do Espa?o intervertebral, totalizando 40,1% dos casos em que haviam achados. O trabalho verificou que a mistura racial, conhecida como Sem ra?a definida (SRD), est? difundida no meio nacional em grande quantidade, sendo esta mistura racial foi a mais radiografada, com 36,79% dos laudos.
163

Perfil de citocinas em pacientes com espondilite anquilosante

Rabelo, Cristina Ferreira 25 August 2016 (has links)
Submitted by Setor de Tratamento da Informa??o - BC/PUCRS (tede2@pucrs.br) on 2016-10-10T17:55:13Z No. of bitstreams: 1 DIS_CRISTINA_FERREIRA_RABELO_COMPLETO.pdf: 3960045 bytes, checksum: 1fdef0c1c7079201f764fd94d443d2a3 (MD5) / Made available in DSpace on 2016-10-10T17:55:13Z (GMT). No. of bitstreams: 1 DIS_CRISTINA_FERREIRA_RABELO_COMPLETO.pdf: 3960045 bytes, checksum: 1fdef0c1c7079201f764fd94d443d2a3 (MD5) Previous issue date: 2016-08-25 / Introduction.Ankylosing spondylitis (AS) is a chronic disease featuring axial changes, peripheral arthritis and systemic involvement. Proinflamammatory cytokines are probably involved in AS pathogenesis. The relationship of circulating cytokines with instruments of AS evaluation is an open field. We herein compared serum levels of cytokines in AS patients and healthy controls, and searched for correlations of cytokines with indexes of disease activity and quality of life. Methods. In this cross-sectional study, 32 AS patients and 32 age-and-sex matched controls were evaluated. BASDAI, BASFI, BASMI, ASDAS-CRP, MASES, ASQol and PGA were measured in AS patients. The soluble cytokines IL-6, IL-8, IL-1, IL-10, TNF-?, IL-12p70 and IL-17 were quantified by flow cytometry. IL-23 concentrations were obtained in an ELISA. Results. Overall, AS patients were predominantly males (59.4%) and Caucasians (96.9%). Mean age was 46.9?10.7 years. HLA B27 was present in 70% of cases. Concentrations of IL-6, IL-8, IL-10 and TNF-? were higher in AS cases than controls. Mean concentration of IL-6 correlated with the BASMI, an index of axial mobility (rs= 0.354, p=0.047). Anti-TNF intake (present in 21 patients, 65.6%) associated with a high BASMI (p=0.042) and lower quality of life as measured by the ASQol (p=0.009). Conclusions. A proinflammatory cytokine profile predominated in AS patients, but interestingly the IL-10 concentrations were also elevated, pointing to an attempt of a suppressive control of inflammation. A defined correlation of serum IL-6 with the BASMI suggests a role for this cytokine in axial disease. Anti-TNF users had more axial activity and lower quality of life. / Introdu??o. A espondilite anquilosante (EA) ? uma doen?a inflamat?ria cr?nica que acomete predominantemente o esqueleto axial (coluna vertebral e articula??es sacril?acas); observa-se tamb?m artrite perif?rica e manifesta??es sist?micas. Citocinas pr?-inflamat?rias provavelmente est?o envolvidas na patog?nese da EA. A correla??o entre as concentra??es s?ricas de citocinas com instrumentos de avalia??o cl?nica na EA ? tema em aberto. Nesta pesquisa comparamos n?veis s?ricos de citocinas em pacientes com EA e controles saud?veis e correlacionamos com ?ndices de atividade de doen?a e qualidade de vida. M?todos. Estudo transversal, controlado, incluiu 32 pacientes pareados por idade e sexo com 32 controles saud?veis. Os instrumentos de avalia??o cl?nica BASDAI, ASDAS-PCR, BASFI, BASMI, MASES, ASQoL e AGP foram aplicados nos pacientes com EA. As citocinas sol?veis IL-6, IL-8, IL1?, IL-10, TNF-?, IL-12p70 e IL-17 foram quantificadas por citometria de fluxo. As concentra??es de IL-23 foram obtidas por ELISA. Resultados. Os paciente com EA eram predominantemente homens (59.4%) e caucasianos (96.9%). A idade m?dia foi de 46.9 (?10.7 anos). O HLA-B27 estava presente em 70% dos casos. Concentra??es de IL-6, IL-8, TNF-? e IL-10 estavam mais elevadas nos pacientes com EA em rela??o aos controles. As concentra??es m?dias de IL-6 se correlacionaram com o BASMI, um ?ndice que avalia a mobilidade axial (rs=0.354, p=0.047). O uso de medica??es anti-TNF (presente em 21 pacientes, 65.6%) foi associado a um BASMI elevado (p= 0.042), significando pior mobilidade axial, e baixa qualidade de vida avaliada pelo ASQoL (p=0.009). Conclus?es. Um perfil de citocinas pr?-inflamat?rias predominou nos pacientes com EA; de forma intrigante a IL-10, uma citocina anti-inflamat?ria, tamb?m estava elevada, indicando uma tend?ncia a um controle supressivo da inflama??o. A correla??o significativa da IL-6 com o BASMI sugere a participa??o desta citocina na les?o axial. Usu?rios de anti-TNF tiveram mais les?o axial e pior qualidade de vida.
164

Ação da acupuntura auricular chinesa sobre a dor crônica em pessoas com distúrbios musculoesqueléticos na coluna vertebral: ensaio clínico randomizado

MOURA, Caroline de Castro 26 August 2016 (has links)
A dor crônica é uma das principais queixas das pessoas com distúrbios relacionados ao sistema musculoesquelético; produz impacto negativo na qualidade de suas vidas, além de consequências econômicas e sociais. Diante disso, as Práticas Integrativas e Complementares têm sido utilizadas com a finalidade de reduzir a experiência dolorosa crônica, em que se destaca a acupuntura auricular. Essa intervenção consiste em uma técnica terapêutica da acupuntura e trabalha com a estimulação de pontos reflexos específicos no pavilhão auricular para aliviar sinais e sintomas de diversas doenças e, dentre estas, a dor. Logo, o objetivo deste estudo foi avaliar a ação da acupuntura auricular chinesa sobre a dor crônica em pessoas com distúrbios musculoesqueléticas na coluna vertebral. Trata-se de um ensaio clínico randomizado realizado entre os meses de junho de 2015 e março de 2016. A amostra final foi constituída por 110 pessoas com dor crônica na coluna vertebral há, no mínimo, três meses, que estavam cadastradas na lista de espera da Clínica de Fisioterapia e no Centro Integrado de Assistência ao Servidor da UNIFAL-MG. Por meio da randomização, após a avaliação inicial, os participantes foram alocados em três grupos: Grupo Tratado (n = 37), que recebeu 05 sessões de acupuntura auricular fundamentada nos preceitos da Medicina Tradicional Chinesa; Grupo Placebo (n=36), que foi submetido à acupuntura auricular com estímulo de pontos que não tinham ligação com o foco de observação; e Grupo Controle (n=37), que não recebeu a intervenção auricular. Todos os participantes foram avaliados por um profissional treinado, em três momentos: inicialmente (antes de qualquer intervenção); uma semana após a última sessão de acupuntura auricular, e 15 dias após a segunda avaliação (Follow up). Para isso, foram utilizados o Instrumento de caracterização do sujeito, o Inventário breve de dor, o Questionário de incapacidade de Roland Morris, além da avaliação do limiar nociceptivo frente ao estímulo mecânico, realizado com o auxílio de um algômetro digital, e da avaliação da temperatura tissular, aferida por meio de uma câmera termográfica. Os dados foram analisados por intenção de tratar e o tratamento estatístico foi realizado por meio dos testes: Qui-quadrado, Kruskal-Wallis, seguido pelo Student-Newman Keuls quando necessário; McNemar e Wilcoxon emparelhado. Os resultados demonstraram que a severidade e a interferência da dor nas atividades cotidianas reduziram nos grupos tratado e placebo durante o período de tratamento, e permaneceram as mesmas na avaliação follow up somente para o grupo placebo. Além disso, a acupuntura auricular também proporcionou alívio significativo da dor para esses dois grupos; contudo, este diminuiu no grupo tratado na avaliação follow up e permaneceu para o grupo placebo. Houve, ainda, redução na incapacidade física, para os grupos tratado e placebo, que foi mais expressiva para o grupo tratado, e permaneceu na avaliação follow up para os dois grupos. Por sua vez, obteve-se aumento da temperatura tissular entre as avaliações final e follow up para os grupos tratado e placebo. O grupo controle não sofreu influência significativa dessas variáveis. O limiar nociceptivo frente ao estímulo mecânico não apresentou variações consideráveis. Diante disso, percebe-se a efetividade da acupuntura auricular chinesa sobre os parâmetros comportamentais e fisiológicos da dor crônica na coluna vertebral. / Chronic pain is one of the main complaints of people with disorders related to the musculoskeletal system; it produces negative impact on the quality of their lives, besides economic and social consequences. Thus, integrative and complementary practices have been used, highlighting auricular acupuncture, in order to reduce chronic painful experience. This intervention consists of an acupuncture therapy technique that works stimulating specific reflex points in the ear, relieving signs and symptoms of various diseases, among them pain. Therefore, the aim of this study was to evaluate the effect of Chinese auricular acupuncture on chronic pain in people with musculoskeletal disorders in the spine. This is a randomized clinical trial held between June 2015 and March 2016. The final sample consisted of 110 people with chronic pain in the spine, for at least three months, registered on the waiting list of the physical therapy clinic and server’s integrated assistance center at UNIFAL-MG. After the initial evaluation, the participants were divided into three groups through randomization: A treated group (n = 37), which received 05 auricular acupuncture sessions based on the precepts of Traditional Chinese Medicine; a placebo group (n = 36) who underwent auricular acupuncture with stimulation points that did not have any connection with the observation focus; and a control group (n = 37) who did not receive the intervention headset. A trained professional evaluated all participants, in three stages: first (before any intervention); a week after the last session of auricular acupuncture, and 15 days after the second evaluation (follow up). The subject characterization instrument, Brief Pain Inventory, and Roland Morris Disability Questionnaire were used, besides the nociceptive threshold in front of mechanical stimulation’s assessment, carried out with the aid of a digital algometry, and tissue temperature evaluation measured by means of a thermo-graphic camera. Data were analyzed with the intention of treating and the statistical analysis was performed through the following tests: Chi-square, Kruskal-Wallis, followed by the Student-Newman Keuls, when necessary; as well as paired McNemar and Wilcoxon. The results showed that pain severity and its interference with daily activities decreased in the treated and placebo groups during the treatment period and remained the same in the follow-up assessment only for the placebo group. Moreover, auricular acupuncture also provided a significant pain relief in these two groups; however, this decreased in the treated group in the follow up evaluation but stayed the same for the placebo group. There was also a reduction in physical disability, for both treated and placebo groups, being more significant for the treated group, and remained the same in the follow up evaluation for both. Furthermore, there was increased tissue temperature between the final and follow-up assessments for both treated and placebo groups. The control group did not show any significant influence for these variables. The nociceptive threshold in front of mechanical stimulation showed no significant variations. Thus, the effect of Chinese auricular acupuncture is clear in behavioral and physiological parameters of chronic pain in the spine. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES
165

Desenvolvimento de colunas capilares e aplicação de programação de temperatura em cromatografia líquida capilar / Development of capillary columns and application of temperature programming in capillary liquid chromatography

Vivane Lopes Leal 23 November 2018 (has links)
O presente estudo visa o desenvolvimento de pesquisas em uma área altamente promissora da cromatografia líquida moderna, denominada genericamente de cromatografia líquida capilar (cLC). Sua principal característica é o uso de instrumentação miniaturizada, cujos benefícios em relação à HPLC são fartamente documentados. O Grupo de Cromatografia do IQSC-USP vem desenvolvendo, há vários anos, instrumentação e colunas para esta área, havendo construído um sistema, para micro e nano LC, completo. O objetivo deste trabalho foi ampliar o emprego do mesmo, através do uso de programação de temperatura em cromatografia líquida capilar, fazendo uso de colunas empacotadas e tubulares abertas (OT), desenvolvidas no laboratório. Uma metodologia relativamente simples foi desenvolvida para preparar as colunas capilares com fases estacionárias C18 com boa repetitividade. Para tal, a influência de várias características da coluna, tais como, tamanho da partícula, comprimento, diâmetro interno, tipos de hardwares empregados como corpo da coluna e sistema de bombeamento, foram avaliadas, sendo estabelecida uma relação entre as mesmas e o desempenho da coluna. As microcolunas empacotadas obtidas apresentaram excelente desempenho. Colunas tubulares abertas, OT do tipo WCOT e PLOT (com diferentes tipos de fases, comprimentos e diâmetros internos) foram produzidas e avaliadas, utilizando uma mistura de alquilbenzenos. Os resultados sugerem um desempenho ainda insatisfatório das colunas OTLC, embora os compostos avaliados tenham sido separados indicando, de forma promissora, que uma otimização nas características das colunas poderá contribuir para se alcançar maiores eficiências. Foi aplicada programação de temperatura na separação de diferentes classes de compostos resultando na redução de, pelo menos, metade do tempo de análise com aumento da eficiência de, no mínimo 2 vezes, quando comparado à separação realizada em condição isotérmica. Isto ilustra a importância da utilização da programação de temperatura em cromatografia líquida capilar. Por último, foi avaliado o desempenho de uma coluna capilar empacotada em um sistema cLC comercial e no cLC desenvolvido no laboratório, onde se observou que o desempenho da coluna foi melhor quando utilizada no cromatógrafo líquido capilar desenvolvido pelo grupo (\"homemade\"). / The present study aims to develop research in a highly promising field of general report generation, generally referred to as capillary liquid chromatography (cLC). Its main feature is the use of miniaturized instrumentation, whose benefits in relation to HPLC are well documented. O Grupo de Cromatografia do IQSC-USP vem desenvolvendo, há vários anos, instrumentação e colunas para esta área, havendo construído um sistema, para micro e nano LC, completo. The objective of this work was to extend the use of the same, by using temperature programming in capillary liquid chromatography, making use of packed and open tubular columns (OT), developed in the laboratory. A relatively simple methodology was developed to prepare capillary columns with C18 stationary phases with good repeatability. To do this, the influence of various column characteristics, such as particle size, length, internal diameter, types of hardware used as column body and pumping system, were evaluated, establishing a relationship between them and the performance of the column. The packaged microcolumns obtained showed excellent performance. Open tubular columns, OT WCOT and PLOT (with different types of phases, lengths and internal diameters) were produced and evaluated using a mixture of alkylbenzenes. The results suggest a still unsatisfactory performance of the OTLC columns, although the compounds evaluated were promising, indicating that an optimization of the characteristics of the columns could contribute to higher efficiencies. Temperature programming was applied in the separation of different classes of compounds resulting in the reduction of at least half of the analysis time with increase of the efficiency of at least 2 times when compared to the separation realized in isothermal condition. This illustrates the importance of using temperature programming in capillary liquid chromatography. Finally, the performance of a capillary column packed in a commercial cLC system and in the cLC developed in the laboratory was evaluated, where it was observed that the performance of the column was better when used in the liquid capillary chromatograph developed by the group (\"homemade\").
166

Estudo da correlação biomecânica entre desordens oclusais e desvio de coluna no plano sagital / Study of biomechanics correlaction between oclusal disorders and spine deviation in the sagital plane

Bittar, Ana Elise Lobo 12 November 2007 (has links)
Este estudo avaliou biomecanicamente o efeito da força resultante, em região de coluna cervical, exercida por um aparelho odontológico ortopédico mecânico, instalado em um paciente tipo classe III de Angle, durante o período de 06 meses. Para isso, selecionou-se um paciente de 10 anos e 04 meses de idade, leucoderma, do sexo masculino, para servir de modelo para este estudo. Ao exame intra-oral foram observadas chave de molares em classe III de Angle, mordida cruzada anterior, dentição mista e arcada superior atrésica. Na avaliação radiográfica, juntamente com análises de USP, Mac Namara, Bimler e Petrovic, foram constatadas maloclusão tipo classe III e potencial de crescimento mandibular maior que maxilar. Na análise de modelos, observaram-se, discrepâncias positivas tanto no sentido transversal como ântero-posterior nas duas arcadas. Foram solicitados exames radiográficos panorâmico, tele-radiografia lateral e de coluna torácica para elaboração do diagnóstico e plano de tratamento. Após isso, foi proposta a disjunção da arcada superior através de disjuntor de Mc Namara modificado e tracionamento da maxila com máscara facial de Petit, utilizando para isso, elásticos extra-orais com tração de força média (400gf). Após o uso da máscara por 06 meses, numa média de 14 horas por dia, foram feitas novas radiografias crânio cervicais para a avaliação da nova situação. O que se pode observar, além da correção da mordida cruzada anterior (clinicamente), foi, radiograficamente, a flexão da coluna do paciente com uma extensão compensatória do crânio e encurtamento de alguns músculos extensores da coluna cervical, analisados em seus marcos ósseos de origem e inserção. / This study has evaluated biomechanicaly the effect of the resultant strength at the cervical column developed by an odonthologic orthopedical mechanic appliance installed in a class III of Angle patient during 6 months. The model for this study is a 10 years and 4 months old patient, during six months. The model for this study is a 10 years and 4 months old patient, male and white. By the intra-oral exam it was possible to observe that the patient had molars in class III of Angle, previous crossed bite, mixed teething and the superior arcade is atresical. By the radiographic evaluation with analysis from USP, Mac Namara, Bimler e Petrovic, was detected a malocclusion class III and a potential of bigger mandibular growth then jaw. By the model analysis, a positive differences in the transversal as well as in the antero-posterior region of both arcades. Panoramic radiological exams, lateral and thoracic vertebral column teleradiografic exams were done in order to elaborate a diagnosis and a treatment plan. Afterwards a disjunction from the superior arcade through a modified disjunctor was proposed and a maxilla tracking through a Petit facial mask, with intra oral gummy strings with a medium strength force (400gf). After using this mask for 6 months, about 14 hours a day, other cranial-cervical x rays were done to evaluate the new results. It\'s possible to observe that not only the crossed bite was corrected (clinically) but also the cervical column flexion from the patient with a compensatory cranial extension. A shortening of some extensor muscles of cervical column, analyzed in its osseous marks of origin and insertion, was also observed.
167

Valores de referência e confiabilidade de testes clínicos para avaliação funcional lombopélvica / Reference values and reliability for tests of lumbopelvic functional assessment

Oliveira, Isadora Orlando de 16 September 2016 (has links)
Introdução: Força, resistência e atividade muscular são uma área importante de pesquisa e avaliação contribuindo para um melhor entendimento de aspectos musculoesqueléticos de mecanismos de dor e lesão. No entanto, a utilização de testes que avaliem a região lombopélvica ainda é controversa, pois apesar de muitos testes clínicos estarem disponíveis na literatura, ainda não estão estabelecidos quais os mais confiáveis na prática clínica. Objetivos: Estabelecer valores de referência, determinar confiabilidade intra e interexaminador e as medidas de erro de um conjunto de testes clínicos que avaliam a região lombopélvica em indivíduos assintomáticos de diferentes gêneros, faixas etárias e níveis de atividade física. Materiais e Métodos: Para os valores de referência, 152 indivíduos (79 homens, 73 mulheres) estratificados por gênero, faixa etária e nível de atividade física realizaram um conjunto de nove testes clínicos: força isométrica máxima de abdutores, extensores, flexores e rotadores laterais de quadril, resistência nas posições de ponte lateral, ponte frontal, flexores e extensores lombares e atividade muscular da região lombopélvica. Para a confiabilidade, 33 indivíduos foram avaliados por dois examinadores em um intervalo de 3 a 7 dias, onde realizaram aleatoriamente o mesmo conjunto de testes. As medidas de confiabilidade foram avaliadas pelo Coeficiente de Correlação Interclasse (CCI2,1) e as medidas de erro definidas pelo Erro Padrão da Medida (EPM) e pela Mínima Mudança Detectável (MMD). Resultados: Foram observadas diferenças significativas (p<0.05) nos testes clínicos para as variáveis: gênero, faixa etária e nível de atividade física e estabelecidos valores de referência para cada grupo. Todos os testes apresentaram valores de confiabilidade excelente com CCI (IC 95%) maior que 0.8 para as confiabilidades intra e interexaminador; os valores da MMD foram superiores à média do EPM em todos os testes. Conclusão: Os resultados do presente estudo apontam valores de referência que contribuem com o estabelecimento de referências para auxiliar na tomada de decisões clínicas. Além disso, este conjunto de 10 testes apresentou confiabilidade intra e interexaminador bem como valores de EPM e MMD, confirmando a possibilidade de seu uso na prática clínica. / Background: The assessment of the lumbopelvic region is useful for many musculoskeletal dysfunctions. Several clinical tests are commonly used to assess this region, however, reference values for clinical assessments and results concerning method, reliability and error measurements of these tests have not been reported. Objectives: To establish reference values and to determine intra and interrater reliability, standard error of measurement (SEM) and minimum detectable change (MDC) of a set of clinical tests used for assessing the lumbopelvic region in asymptomatic volunteers of different gender, age groups and physical activity levels. Methods: For reference values, 152 subjects (79 men, 73 women) divided by gender, age group and physical activity levels, performed nine clinical tests: Maximum voluntary isometric strength of hip abductors, extensors, flexors and lateral rotators, transversus abdominis(TrA) muscle activity (using a Pressure Biofeedback Unit), prone and side bridges, trunk flexor and extensor endurance tests. To measure reliability, 33 individuals performed the same set of tests, in random order within a week period. Intrarater and interrater analysis were assessed using the Intraclass Correlation Coefficient (ICC) and the error measurements were defined by using the SEM and the MDC. Results: Reference values were established for each group and our results showed significant (p<0.05) differences concerning gender, age group and physical activity levels in clinical tests. In general, strength differences were related to gender and physical activity levels and endurance results could be related to interactions between gender, age group and physical activity levels. All tests presented good reliability indices with an ICC (95%CI) higher than 0.8 for the intrarater and interrater reliability; MDC values were greater than mean of SEM in all tests, confirming its usage for clinical practice assessments. Conclusion: Reference values are necessary to help clinicians in the evaluation of subjects and these results can contribute for clinical practice in providing clinical training targets. Also, this set of tests presented good intra and interrater reliability measures of strength, endurance and TrA muscle activity test as well as SEM and MDC values, confirming its use for assessing the lumbopelvic region.
168

Controlador IHMPC robusto com otimizador linear integrado. / Robust IHMPC control with integrated linear optimizer.

Zampieri, Daniel Henrique Parisi 03 April 2019 (has links)
Este trabalho tem como objetivo estudar as características de uma coluna depropanizadora e propor uma estrutura de controle para esta planta. Essa coluna está localizada na unidade de craqueamento catalítico da Refinaria Presidente Bernardes, em Cubatão. O objetivo de controle é a especificação de um valor máximo de butano e componentes mais pesados (C4+) na corrente de topo e um valor máximo de propano e componentes mais leves (C3-) na corrente de fundo. Uma simulação da planta foi construída por meio do simulador de processos AspenOne® e os modelos referentes a vários pontos de operação e duas composições de carga distintas foram obtidos através da simulação integrada entre o Aspen® e o Simulink®. O software Matlab(TM) foi utilizado para executar o algoritmo de controle. O controlador aqui proposto é um IHMPC (Infinite Horizon Model Predictive Control) adaptado para sistemas com tempo morto e com faixas nas variáveis controladas. As incertezas na modelagem foram representadas por um conjunto de modelos lineares. Adicionalmente o controlador contém, na mesma camada, um componente de otimização econômica linear com o objetivo de minimizar o gasto energético do sistema ou até mesmo maximizar a pureza do destilado. As simulações permitiram que as estratégias de controle pudessem ser testadas e seus resultados discutidos. A análise dos testes mostra que o IHMPC aqui proposto é capaz de controlar a planta nos possíveis pontos de operação com um bom desempenho. / The objective of this work is to study the characteristics of a depropanizer column and to propose a predictive control structure for this plant. This column is located at the fluid catalytic cracking unit of the Presidente Bernardes Refinery, in Cubatão. The control objective of these columns is the specification of a maximum value of butane and heavier components (C4+) in the top stream and the maximum value of propane and lighter components (C3-) in the bottom stream. The plant was represented through the process simulator AspenOne® and the models for several operating points and two different feed compositions were obtained through the integrated simulation of Aspen® and Simulink®. The software Matlab(TM) was used to run the control algorithm. The controller proposed here is based on the IHMPC (Infinite Horizon Model Predictive Control) that was extended to time delayed systems and zone control. The model uncertainties are approximated by a set of linear models. In addition, the controller contains, in the same layer, an economic objective, which aims to minimize the energy contents of the operation and to maximize the purity of the distillate. The simulation allowed that the control strategies could be tested and the results discussed. The analysis of the tests showed that the proposed IHMPC is able to control the plant with acceptable performance.
169

Prevalencia de osteoporose, fraturas vertebrais, ingestao de calcio e deficiencia de vitamina D em mulheres pos-menopausa

Farias, Francisco Alfredo Bandeira e. January 2003 (has links) (PDF)
Doutor -- Escola Nacional de Saude Publica, Rio de Janeiro, 2003.
170

Estudo da aplicação de força durante a técnica de mobilização póstero anterior central na coluna lombar

Muta, Henrique Shimanuki [UNESP] 01 1900 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:34Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-01Bitstream added on 2014-06-13T18:57:57Z : No. of bitstreams: 1 muta_hs_me_guara.pdf: 492160 bytes, checksum: c31427e991b74ee256fe65b5d34cc2ce (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Na fisioterapia existem procedimentos que dependem da percepção manual do fisioterapeuta por estarem relacionados à aplicação de forças graduadas. Alguns estudos demonstraram que há uma grande dificuldade na percepção da força, ocorrendo grande variabilidade em sua aplicação. O objetivo deste estudo foi desenvolver um equipamento portátil para a medida de forças aplicadas por fisioterapeutas durante a realização da técnica de pressão póstero anterior central na coluna lombar e analisar alguns parâmetros envolvidos no método de mobilização articular. Houve variabilidade na forma de aplicação das cargas em diferentes aspectos. Dessa forma, podemos demonstrar com esses resultados, que a percepção manual do fisioterapeuta durante a realização da técnica de pressão póstero anterior central não foi tão precisa comparando os valores estimados com os valores das cargas aplicadas durante o intervalo de coleta. / In Physical Therapy there are some procedures that depend on manual sensibility of physical therapist because that involves graded forces. Some studies have shown that there is a great difficulty in the perception of the force, occuring great variability on the application. The purpose of this study is to develop a portable device to measure the forces applied by physical therapists during the procedure of posteroanterior central pressure in the lumbar spine and to analyze some parameter involved in the method of articular mobilization. There was variability in application of the technique in many ways. Therefore, we can show with these results that the manual sensibility of the physical therapists during the application of the posteroanterior central pressure technique wasnþt accurate comparing the estimated values to the actual results obtained during the experiment interval of time.

Page generated in 0.0238 seconds