• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 449
  • 18
  • 18
  • 18
  • 18
  • 14
  • 14
  • 14
  • 14
  • 12
  • 6
  • 4
  • 3
  • 2
  • Tagged with
  • 473
  • 249
  • 127
  • 116
  • 54
  • 54
  • 53
  • 51
  • 51
  • 45
  • 44
  • 40
  • 33
  • 29
  • 27
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Análise teórica e experimental de ligações em aço entre pilar tubular de seção circular e viga de seção I / Theoretical and experimental analysis of steel connections between circular hollow section column and I section beam

Calil Zumerle Masioli 15 April 2011 (has links)
O atrativo estético proporcionado pela forma arredondada é o fator que na maioria das vezes determina a utilização de estruturas tubulares circulares. É crescente a concepção de pórticos formados por colunas tubulares e as tradicionais vigas de seção I. Esse tipo de ligação ainda é pouco estudado no Brasil, e esse trabalho busca avançar no entendimento do comportamento estrutural dessas ligações. Foram realizados estudos analíticos, numéricos e experimentais em quatro configurações de ligação, com diafragmas externos transversais, chapa de alma, soldas, parafusos e enrijecedor. Avaliou-se a relação M-\'fi\' (momento-rotação) das ligações estudadas e os parâmetros envolvidos como resistência, rigidez e ductilidade, evidenciando-se o modo de colapso das ligações. O estudo analítico foi desenvolvido baseado nas recomendações do Eurocode 3 (2005), com a utilização do Método das Componentes. A análise numérica, através do Método dos Elementos Finitos, foi realizada por meio dos programas computacionais TRUEGRID® e ANSYS®. Os modelos numéricos consideram as características mecânicas do aço, como plastificação, encruamento e não-linearidades geométricas e de contato. As formulações do Eurocode 3 (2005), adaptadas para a determinação da resistência das ligações viga-coluna, apresentaram resultados coerentes e a análise numérica foi representativa frente aos resultados experimentais. A utilização de diafragmas externos conectados à viga apresentou boa funcionalidade, ajudando na distribuição das tensões na região da ligação, melhorando o comportamento da coluna. / The aesthetic appeal provided by the round shape is the factor that mostly determines the use of circular tubular structures. There is an increasing conception of structures formed by hollow columns and traditional beams of section I. This type of connection hasn\' t been sufficiently studied in Brazil, and this paper tries to advance the comprehension of the structural behavior of these connections. Analytical, numerical, and experimental study were performed in four connections configurations, with transverse external diaphragms, web plate, welds, bolts and stiffener. The relation M-\'fi\' (moment-rotation) of the studied connections and the parameters involved such as strength, stiffness and ductility were evaluated, evidencing the failure mode of connections. The analytical study was developed based on recommendations of Eurocode 3 (2005) using the Method of Components. The numerical analysis using the Finite Element Method was performed with the computer programs TRUEGRID® and ANSYS®. The numerical models consider the mechanical characteristics of steel, such as yielding and hardening, and also the geometric and contact nonlinearity. The formulations of Eurocode 3 (2005), adapted for determining the strength of beam-column connections, showed coherent results and the numerical analysis was representative compared to experimental results. The use of external diaphragm connected to the beam showed good functionality, helping in the distribution of stress in the region of connection, improving the behavior of the column.
232

Desenvolvimento de um macromodelo biomecânico tridimensional da coluna vertebral durante tarefas de levantamento

La Torre, Marcelo January 2009 (has links)
As atividades desenvolvidas pelo ser humano traduzem-se em grandes esforços internos, sobre as mais variadas estruturas corporais. O conhecimento da magnitude destes esforços pode auxiliar profissionais da área da saúde em atividades como prescrição de exercícios, reabilitação e prevenção de lesões. A magnitude dos esforços internos pode ser obtida por meio de um método direto ou indireto. O método direto esbarra em questões éticas e limitações tecnológicas, enquanto que o método analítico indireto por meio do conhecimento de parâmetros biomecânicos externos pode inferir sobre os esforços internos. Assim o objetivo deste estudo foi implementar um Macromodelo biomecânico tridimensional da coluna vertebral (MM3D), para cálculo das forças internas, articular e muscular resultantes, durante diferentes tarefas de levantamento de carga. O MM3D implementado consiste de um modelo de segmentos articulados (MSA-3D) o qual é composto por dezesseis segmentos rígidos conectados associados a um Modelo de distribuição (MDFMA) o qual fornece as forças musculares (FM) e articulares (FA) resultantes em três níveis da coluna vertebral (superior, médio e inferior). No MSA-3D as forças e momentos proximais líquidos são obtidos a partir da resolução das equações de movimento de Newton-Euler por meio da solução inversa. Com base nas forças e momentos proximais líquidos obtidos do MSA-3D o MDFMA baseado em técnicas de otimização e dados da literatura fornece as FM e FA resultantes na coluna vertebral. A tarefa avaliada consistiu do levantamento de um objeto com 20% da massa corporal do indivíduo em três diferentes técnicas de levantamento. Para registro cinemático foram utilizadas cinco câmeras digitais, com freqüência de amostragem de 25 Hz. O registro cinético foi realizado por meio da utilização de uma plataforma de força, a base de strain-gauges. Os resultados do MM3D implementado foram avaliados por meio da estimativa da acurácia da medida tridimensional obtida pela cinemetria, pela comparação dos resultados do MSA-3D com os valores mensurados pela plataforma de força, pela comparação da FRP e MP calculados pela via superior e inferior do MSA-3D nos segmentos da coluna vertebral e literatura. Os resultados obtidos sugerem uma coerência do MM3D com informações de mensurações diretas e estimativas indiretas obtidas da literatura. Assim o MM3D se mostrou capaz de avaliar e comparar as FM e FA nos três segmentos da coluna vertebral durante diferentes tarefas de levantamento. / Activities performed by the human being can be translated in large internal loads in the most varied body structures. Knowledge of these loads' magnitude may help health area professionals in activities such as prescription of exercises, rehabilitation and prevention of injuries. Internal load's magnitude may be obtained through direct or indirect methods. Direct method stumbles in ethical questions and technology limitations, while indirect analytic method through knowledge of external biomechanics parameters may deduce internal loads. Thus the objective of this study was to implement a tridimensional biomechanical macromodel of the spine (MM3D) to calculate internal forces, joint and muscular resultants, during different tasks of weight lifting. The implemented MM3D consists of an articulated segments model (MSA-3D) composed by sixteen rigid segments connected associated to a distribution Model (MDFMA) that provides resultant muscle (FM) and joint (FA) forces in three levels of the spine (superior, medium and inferior). At the MSA-3D liquid forces and proximal moments are obtained from the resolution of Newton-Euler movement equations through inverse solution. Based in the MSA-3D liquid forces and proximal moments obtained, the MDFMA, based in optimization techniques and data from literature, provides spine resultants FM and FA. The evaluated task consisted of lifting an object with 20% of the subjects' body weight using three different lifting techniques. For kinematics records five digital video cameras were used, with sampling frequency of 25 Hz. Kinetic record was performed using a force platform (strain-gauges based). MM3D implemented results were evaluated through accuracy estimation of the tridimensional measures obtained from kinematics, through comparison of the MSA-3D results and values measured by the force platform, through comparison of spine's segments calculated proximal resultant force and proximal moment calculated through upper and lower ways of MSA-3D and literature. Results suggest a coherence of direct measured information of MM3D and indirect estimative obtained from literature. Thus MM3D showed capable of evaluating and comparing FM and FA at the spine's three segments during different lifting tasks.
233

Modelo biomecânico tridimensional para análise das forças internas atuantes na coluna cervical superior e inferior durante o ciclismo

Pasini, Maicon January 2009 (has links)
Elevados índices de dor cervical e lombar têm sido reportados em ciclistas. Fatores como a postura adotada na bicicleta, a ativação dos músculos extensores da coluna e a ação de cargas mecânicas nas estruturas da coluna tem sido apontados como possíveis causas da dor. Embora relatados e aparentemente aceitos, poucos estudos objetivaram investigar estes fatores. Em adição, a dor crônica não específica é frequentemente diagnosticada em ciclistas, pois poucas evidências de anormalidade são observadas quando realizados exames radiológicos clínicos. O emprego de métodos biomecânicos de investigação, como a estimativa da magnitude da força muscular dos extensores da coluna e da força articular em diferentes níveis da coluna poderia contribuir para avaliação do risco de lesão e dor em decorrência do ciclismo, além de auxiliar na criação de estratégias de prevenção e programas de reabilitação. Assim, este estudo teve como objetivo quantificar e comparar as forças internas atuantes na coluna cervical durante o ciclismo em diferentes posturas, por meio do desenvolvimento e aplicação de um modelo biomecânico tridimensional in vivo. O modelo biomecânico proposto foi composto por dois segmentos rígidos (coluna cervical superior e inferior) conectados. O segmento coluna cervical superior compreende a cabeça, C1 e C2. O segmento coluna cervical inferior compreende as vértebras cervicais de C3 a C7. No segmento coluna cervical superior são considerados dois vetores de força muscular: FM1 (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis superior e obliquus capitis inferior) e FM2 (semispinalis capitis e splenius capitis). Já no segmento coluna cervical inferior estão inclusos os vetores FM3 (semispinalis cervicis) e FM4 (splenius cervicis). A resolução das equações de movimento de Newton-Euler é realizada por meio da solução inversa. Os parâmetros cinemáticos foram obtidos utilizando imagens externas da cabeça e coluna cervical, adquiridas por meio de quatro câmeras de vídeo digital com frequencia de amostragem de 25 Hz. Para estimar a localização dos centros de rotação (C2-3 e C6-7) foram realizados exames radiológicos convencionais estáticos. Os parâmetros de massa e centro de massa foram retirados de tabelas antropométricas da literatura. Participaram do estudo 12 ciclistas com pelo menos dois anos de experiência competitiva cada. O estudo foi aprovado pelo Comitê de Ética em Pesquisa da Universidade Federal do Rio Grande do Sul e os sujeitos assinaram um termo de consentimento livre e esclarecido. Cada participante foi avaliado utilizando sua própria bicicleta acoplada a um ciclossimulador magnético, em duas etapas realizadas no mesmo dia. Inicialmente foi mensurada a massa corporal total do individuo e em seguida identificados e marcados 14 pontos anatômicos de interesse com uma caneta dermatográfica. Durante as avaliações foram fixos marcadores revestidos com papel reflexivo e contendo chumbo no interior em todos os pontos anatômicos de interesse. Na Etapa I os sujeitos pedalaram durante 2 minutos em cada postura (ereta, descanso, intermediária, ataque e cotovelos flexionados), sendo coletados dados cinemáticos durante os últimos 30 segundos de cada uma. Na Etapa II foram realizados exames radiológicos estáticos em cada uma das 5 posturas analisadas (ereta, descanso, intermediária, ataque e cotovelos flexionados) e em flexão e extensão máximas da coluna cervical. Os resultados indicam que as forças internas atuantes nas estruturas da coluna cervical apresentaram maiores magnitudes nas posturas que envolvem a prática do ciclismo (descanso, intermediária, ataque e cotovelos flexionados), quando comparadas a postura de referência (ereta). Observando somente as posturas que envolvem o ciclismo, as forças internas aumentaram gradativamente a medida que os ciclistas transferiram o apoio de suas mãos da região superior para a região inferior do guidão, adotando as posturas descanso, intermediária e ataque, respectivamente. Entretanto, as maiores magnitudes das forças internas foram observadas quando os ciclistas efetuaram o apoio das mãos envolvendo os manetes e flexionaram a articulação do cotovelo (postura cotovelos flexionados). Proporcionalmente os maiores aumentos das forças internas ocorreram na coluna cervical superior, porém as maiores magnitudes das forças internas foram alcançadas na coluna cervical inferior. O processo de avaliação demonstrou que o modelo biomecânico tridimensional da coluna cervical proposto foi considerado capaz de representar de maneira confiável o sistema de interesse. Os resultados encontrados são coerentes, sendo o modelo um instrumento adequado para estimar as forças internas atuantes na coluna cervical durante o ciclismo em diferentes posturas. / High index of cervical and lumbar pain had been registered in cyclists. Factors as a posture adopted on bicycle, the activity of spine extensor muscles and the action of mechanical load in the spine structures had been put like possible causes of pain. Although related and apparently accepted, few studies investigate these factors. In addition, the non-specific chronic pain is frequently diagnosed in cyclists, because few evidences of abnormalities are investigated when clinic radiologics exams are done. The use of biomechanical methods of investigation, like the estimate of muscular force magnitude of extensors of spine and of joint force in different levels of spine can be contributed to evaluation of injury risk and pain caused by cycling, beyond the assist in strategies of prevention and rehabilitation programs. Therefore, this study had like objective to quantify and compare the active internal forces in the cervical spine during cycling in different postures, through development and application of three dimensional in vivo biomechanical model. The biomechanical model suggested was compound by two rigid segments (upper and lower cervical spine) connected. The upper cervical spine segment include head, C1 and C2. The lower cervical spine segment include cervical vertebraes of C3 to C7. In the upper cervical spine segment are considered two vectors of muscular force: FM1 (rectus capitis posterior major, rectus capitis posterior minor, obliquus capitis superior e obliquus capitis inferior) and FM2 (semispinalis capitis e splenius capitis). In the lower cervical spine segment are included the vectors FM3 (semispinalis cervicis) and FM4 (splenius cervicis). The resolution of movement equation of Newton-Euler is done through inverse dynamics. The kinematic parameters were obtained using external images of head and cervical spine, acquired by four digital video cameras with sampling frequency of 25 Hz. To estimate the location of rotation centers (C2-3 and C6-7) statics conventional radiologic exams were done. The parameters of mass and center of mass were removed of anthropometric tables of literature. 12 cyclists with at least two years of competitive experience each one participated of the study. The study was approved by Ethics Committee in Researches of Federal University of Rio Grande do Sul and the subjects signed a free and clear consent term. Each participant was assessed using your bicycle attached in a magnetic cycle simulator, in two stages done in the same day. Initially the total body mass of subjects was measured and then 14 anatomic points of interest were identified and marked with a dermatography pen. During the evaluation markers encased with reflective paper and containing lead inside of these markers were fixed in all anatomic points of interest. In the stage I the subjects rode a bicycle during 2 minutes in each posture (upright neutral, rest, intermediate, attack and flexed elbows). The kinematic data were collected during the last 30 seconds of each one. In the stage II static radiologic exams were done in each of 5 analyzed postures (upright neutral, rest, intermediate, attack and flexed elbows) and in maxim flexion and extension of cervical spine. The results indicate that the internal forces active in the structures of cervical spine presented more magnitudes in the postures that involve the cycling practice (rest, intermediate, attack and flexed elbows), when compared to reference posture (upright neutral). Observing just the postures that involve the cycling, the internal forces gradually increased as cyclists transferred the your hands from upper to lower region of handlebar, adopting the rest, intermediate and attack postures, respectively. However, the greater magnitude of internal forces were observed when the cyclists hands involving the brake levers and flexed the elbow joints (flexed elbows posture). Proportionally the greatest increase of internal forces occurred in the upper cervical spine, however the greatest magnitudes of internal forces were reached in the lower cervical spine. The evaluation process demonstrated that the three dimensional biomechanical model of cervical spine was considered able to represent of reliable way the interest system. The results found are coherent, the model is an adequate instrument to estimate the internal forces active in the cervical spine during cycling in different postures.
234

Alterações nas variáveis mecânicas e energéticas da caminhada decorrentes da dor lombar crônica inespecífica : estudo observacional transversal

Carvalho, Alberito Rodrigo de January 2012 (has links)
Introdução: A dor lombar gera alterações motoras que podem comprometer a caminhada. Contudo, pouco se sabe sobre suas repercussões sobre a cinemática e energética da caminhada. Objetivo: Verificar: a) a correlação entre variáveis cinemáticas da caminhada (intensidade do deslocamento e velocidade horizontal) e variáveis neurofisiológicas e psicossociais da dor lombar (intensidade da dor e nível de incapacidade, respectivamente); b) o efeito da dor lombar crônica sobre parâmetros cinemáticos e metabólicos da caminhada. Métodos: A amostra foi composta por voluntários com dor lombar crônica inespecífica, (GL/ n=6) e indivíduos saudáveis (GC/ n-7). O nível de incapacidade foi obtido pelo Índice de Incapacidade de Oswestry e a intensidade da dor pela escala visual analógica (EVA). As variáveis cinemáticas foram determinadas por cinemetria, e as variáveis metabólicas por análise de gases enquanto os sujeitos caminharam em esteira rolante. A bateria de teste foi dividida em três blocos de acordo com a intensidade do esforço (preferida, abaixo e acima da preferida). Resultados: Não foram observadas correlações entre as variáveis cinemáticas da caminhada e as variáveis neurofisiológicas e psicossocias da dor. Também não se observou efeito da dor lombar sobre os parâmetros cinemáticos. Embora não houvesse diferença entre os grupos nos parâmetros metabólicos, os lombálgicos foram mais econômicos nas velocidades mais baixas. Conclusão: Embora a dor lombar crônica não tenha influenciado os parâmetros mecânicos da caminhada, e não se tenha observado diferenças nos parâmetros metabólicos entre os grupos, a velocidade ótima de caminhada nos lombálgicos parece estar nas baixas velocidades. / Introduction: Low back pain causes motor abnormalities that may impair walking. However, little is known about its effects on the kinematics and energetics of walking. Objectives: To check: a) the correlation between kinematic variables of walking (intensity of displacement and horizontal velocity) and neurophysiological and psychosocial variables of low back pain (pain intensity and disability level, respectively), b) the effect of chronic low back pain on kinematic and metabolic parameters walk. Methods: The sample consisted of patients with chronic nonspecific low back pain, (GL / n=6) and healthy subjects (GC / n=7). The level of disability was obtained by the Oswestry Disability Index and pain intensity by visual analog scale (VAS). The kinematic variables were determined by kinematics, and metabolic variables for gases analysis while the subjects walked on a treadmill. The battery test was divided into three blocks according to the intensity of the effort (preferably above and below the preferred). Results: There were no correlations between the kinematic variables of the walk and the neurophysiological and psychosocial variables of low back pain. Also there was no effect of back pain on the kinematic parameters. Although there was no difference between the groups in metabolic parameters, the lumbar group were more economical in lower speeds. Conclusion: Although chronic back pain did not influence the mechanical parameters of the walk, and has not been seen differences in metabolic parameters between groups, the optimal speed of walking on person with low back pain seems low speeds.
235

Validação de um sistema de escaneamento 3d para avaliação das curvaturas da coluna vertebral de crianças em diferentes perfis nutricionais

Sedrez, Juliana Adami January 2013 (has links)
A presente dissertação de mestrado teve como objetivo verificar a validade concorrente, a repetibilidade, a reprodutibilidade interavaliador, a sensibilidade e a especificidade do sistema Vert 3D na avaliação das curvaturas frontais e sagitais de crianças com diferentes perfis nutricionais. Inicialmente foram realizadas duas revisões sistemáticas da literatura com o objetivo de investigar a existência de evidências científicas sobre os instrumentos de avaliação não invasiva da escoliose, cifose torácica e lordose lombar. A partir dessas revisões sistemáticas foi possível observar que, em geral, os instrumentos apresentaram condições satisfatórias para a avaliação não invasiva das curvaturas da coluna vertebral. Além disso, parece haver consenso na literatura sobre a aplicabilidade dos instrumentos não invasivos, os quais são indicados para o acompanhamento clínico, com o objetivo de reduzir a exposição frequente aos Raios-X sem, no entanto, possibilitar a substituição da radiografia. No entanto, ainda há carência na literatura de estudos com forte evidência científica no que tange a validação dos instrumentos não invasivos de avaliação da coluna vertebral, e por esse motivo, desenvolveu-se um estudo original com a finalidade de investigar os aspectos de validação do sistema Vert 3D. Foram avaliadas 115 crianças, as quais foram submetidas à radiografia panorâmica da coluna vertebral sagital e frontal, além de cinco avaliações com o sistema Vert 3D, por três avaliadores treinados. Os resultados demonstraram que o sistema Vert 3D: (1) apresentou excelentes níveis de repetibilidade e reprodutibilidade interavaliador para os ângulos de cifose torácica e lordose lombar; (2) apresentou fraca correlação com o ângulo de Cobb para cifose torácica e correlação moderada para lordose lombar; (3) para avaliação do plano frontal, o sistema Vert 3D apresentou nível moderado de repetibilidade para flechas à esquerda e nível fraco a moderado para flechas à direita; (4) a reprodutibilidade interavaliador apresentou nível moderado para as flechas escolióticas à direita e à esquerda; (5) não houve correlação significativa entre as flechas à direita e os ângulos Cobb para a direita e houve correlação fraca entre as flechas à esquerda e os ângulos Cobb a esquerda; (6) a repetibilidade e reprodutibilidade interavaliador manteve bons níveis de correlação independente do perfil nutricional avaliado, nos dois planos investigados. Conclui-se que o sistema Vert 3D apresentou adequados níveis de repetibilidade e reprodutibilidade interavaliador para a avaliação de crianças de todos os perfis nutricionais, podendo dessa forma, ser utilizado no acompanhamento clínico das curvaturas da coluna vertebral nos planos frontal e sagital. No entanto, até o presente momento não é possível utilizar esse sistema para o diagnóstico de alterações posturais, nem mesmo para estimar o ângulo de Cobb, já que não foram encontradas adequadas correlações e concordâncias com os exames radiográficos. Ainda, o sistema Vert 3D não tem a pretensão de substituir o exame radiológico, mas pode ser utilizado como uma importante ferramenta no fornecimento de informações adicionais à cerca do posicionamento da superfície do dorso, possibilitando ampliar o conhecimento da avaliação postural, visando um planejamento adequado de intervenções pelos profissionais da saúde. Além disso, com a utilização desse sistema, pode-se reduzir a exposição frequente aos Raios-X. / This master degree dissertation had the objctive of verify the concurrent validity, repeatability, reproducibility interrater, the sensitivity and the specificity of the Vert 3D system in the evaluation of frontal and sagittal curvatures in children with different nutritional profiles. Initially it was performed two systematic reviews of the literature with the purpose of investigate the existence of scientific evidence regarding the instruments of noninvasive evaluation of scoliosis, thoracic kyphosis and lumbar lordosis. Based on these systematic reviews it was possible to observe that, in general, the instruments showed satisfactory conditions for noninvasive evaluation of spinal curvatures. Furthermore, there seems to be a consensus in the literature about the applicability of noninvasive instruments, which are indicated for clinical monitoring, in order to reduce the frequent exposure to X-rays without, however, allowing the replacement of radiography. However, there is still a lack of studies in literature with a strong scientific evidence Regarding the validation of noninvasive evaluation instruments of the spine, and for this reason, it was developed an original study in order to investigate aspects of the validation of the Vert 3D system. It was evaluated 115 children, who underwent panoramic radiography of the spine in sagittal and frontal planes, and five assessments with the Vert 3D system, by three trained raters. The results showed that the the Vert 3D system: (1) showed excellent levels of repeatability and reproducibility Interrater for angles of thoracic kyphosis and lumbar lordosis; (2) showed a weak correlation with the Cobb angle for thoracic kyphosis and moderate correlation for lumbar lordosis; (3) to evaluate the frontal plane the Vert 3D system presented a moderate level of repeatability for arrows to the left and weak to moderate for arrows to the right; (4) the interrater reproducibility showed a moderate level to the scoliosis arrows to the right and left; (5) there was no significant correlation between the arrows to the right and Cobb angles to the right and there was a weak correlation between the arrows to the left and the left Cobb angles; (6) the repeatability and the interrater reproducibility maintained good levels of correlation independent of nutritional status evaluated in the two plans investigated. It is concluded that the Vert 3D system presented adequate levels of repeatability and Interrater reproducibility for the evaluation of children of all nutrient profiles, and can this way it can be used in the clinical monitoring of spinal curvatures in the sagittal and frontal planes. However, until this moment it is not possible to use this system for the diagnosis of postural alterations, not even to estimate the Cobb angle, since were not found appropriate correlations and concordances with radiographs. Still , the Vert 3D system does not intend to replace the radiological examination, but can be used as an important tool in providing information about the positioning of the back surface, making it possible to enhance the knowledge about postural evaluation, seeking a proper planning of interventions by health care professionals. Furthermore, by using this system one can reduce frequent exposure to X-rays.
236

Transporte de \'CU POT.2+\' em liners compostos de solo argiloso compactado (CCL) e geocomposto bentonítico (GCL) / \'CU POT.2+\' transport in composite liners made with compacted clay soil (CCL) and geosynthetic clay liner (GCL)

Paola Bruno Arab 06 September 2011 (has links)
Neste trabalho foi avaliado o desempenho de liners compostos frente a soluções de \'CU\'\'CL IND.2\'.2\'H IND.2\'\'O\'. Foram utilizados um solo argiloso compactado (CCL) da Formação Corumbataí (interior do estado de São Paulo) e um geocomposto bentonítico (GCL) de fabricação nacional. Quatro corpos de prova foram preparados para a realização do ensaio de percolação em coluna, sendo dois montados com CCL sobre GCL e outros dois com GCL sobre CCL. Os corpos de prova com configurações distintas foram submetidos à percolação de duas soluções de \'CU POT.2+\': uma com concentração de 0,024M e outra com 0,012M. Após o início da percolação da solução contaminante houve aumento da condutividade hidráulica, porém os valores mantiveram-se na ordem de \'10 POT.-11\' m/s, compatíveis com as exigências requeridas em diversas legislações ambientais. O liner composto mostrou-se mais eficiente como barreira de controle de fluxo comparado com Musso (2008), que estudou ambos materiais separadamente. A configuração dos liners não influenciou os valores de Rd obtidos, ao contrário da concentração das soluções. Observou-se que os resultados de Rd são inversamente proporcionais às concentrações utilizadas. Neste trabalho, os valores de Rd obtidos foram maiores que em Musso (2008), evidenciando a vantagem de se combinar diferentes materiais para a contenção de íons. / This research evaluated composite liners performance when permeated by \'CU\'\'CL IND.2\'.2\'H IND.2\'\'O\' solution. It were used a compacted clayey soil (CCL) samples from Formação Corumbataí (state of São Paulo) and a geosynthetic clay liner (GCL) manufactured in Brazil. Four specimens were prepared to column percolation tests. A pair of them was made with CCL on top of GCL and the other two with GCL on top of CCL. Specimens with different configurations were subjected to two \'CU POT.2+\' solutions: one with a concentration of 0,024M and other with 0,012M. Just after solution percolation began, there was an increase of hydraulic conductivity, but remaining around \'10 POT.-11\' m/s, in accordance with environmental laws. The composite liners demonstrated to be more efficient as barrier when compared to Musso (2008), which has analyzed both materials separately. The configuration of the liners did not influenced Rd values, unlike solutions concentration. It was observed that Rd results are inversely proportional to used concentrations. Rd values were larger than those obtained in Musso (2008), showing the advantage of matching different materials aiming ions retention.
237

Elaboração de modelos de elementos finitos da coluna vertebral cervical de dogue alemão

BONELLI, Marília de Albuquerque 30 March 2017 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-02-22T12:56:00Z No. of bitstreams: 1 Marilia de Albuquerque Bonelli.pdf: 1903907 bytes, checksum: 8de429c7dc9abc6c230fc38f56331819 (MD5) / Made available in DSpace on 2018-02-22T12:56:00Z (GMT). No. of bitstreams: 1 Marilia de Albuquerque Bonelli.pdf: 1903907 bytes, checksum: 8de429c7dc9abc6c230fc38f56331819 (MD5) Previous issue date: 2017-03-30 / Finite element models aid in understanding dynamic processes in the study of diseases and treatments. Cervical spondylomyelopathy (CSM), also called wobbler syndrome, is a disease that affects mainly large- and giant-breed dogs, and seems to have a static and dynamic component in its pathophysiology. The present objective was to create a finite element model representing the C2-C7 segment of the vertebral column of a Great Dane dog without abnormalities, as well as the adaptation of this model to represent a dorsal laminectomy and a hemilaminectomy at C5-C6. This is expected to contribute to the investigation of the biomechanical component of CSM, as well as allow a comparison of the various surgical methods proposed for treatment of this syndrome. A 2-year-old Great Dane dog without neurologic or imaging changes in the cervical region of the vertebral column was selected. Computed tomography images from this dog were processed to construct a finite element model representing vertebrae, intervertebral discs, and ligaments. Material properties were adapted from the literature. Range of motion of the model under 2Nm for flexion, extension, axial rotation, and lateral bending were compared with literature. Range of motion was observed to be lesser than cited for cadavers of a different breed. This difference could be considered as resulting from differences between breeds and the use of human material properties. When comparing the intact model with the modified laminectomy and hemilaminectomy models, an influence of the hemilaminectomy was observed in range of motion, especially in axial rotation to the side opposite the simulated procedure. Construction of these models would be the first step to applying finite element analysis to the study of CSM in Great Danes. / Modelos de elementos finitos ajudam a entender processos dinâmicos no estudo de doenças e tratamentos. Espondilomielopatia cervical (EMC), também chamada de síndrome de wobbler, é uma doença que afeta principalmente cães de raças grandes e gigantes, e que parece ter um componente estático e dinâmico na sua fisiopatogenia. Objetivou-se criar um modelo de elementos finitos representando o segmento de C2 a C7 da coluna vertebral de um dogue alemão sem alterações, assim como adaptar esse modelo para representar uma laminectomia dorsal e hemilaminectomia em C5-C6. Espera-se com isso contribuir para a investigação do componente biomecânico da EMC, além de permitir a comparação dos diversos métodos cirúrgicos propostos para o tratamento dessa síndrome. Foi selecionado um cão de 2 anos de idade, da raça Dogue alemão, sem alterações neurológicas ou de imagem na região cervical da coluna vertebral. Imagens de tomografia computadorizada deste cão foram processadas para construir um modelo de elementos finitos representando as vértebras, discos intervertebrais e ligamentos. As propriedades materiais foram adaptadas da literatura. A amplitude de movimento do modelo sob 2Nm para flexão, extensão, rotação axial e flexão lateral foram comparadas com a literatura. Observou-se que a amplitude de movimento do modelo foi menor do que a citada para cadáveres de outra raça. Considera-se que essa diferença possa advir de diferenças entre raças e do uso de propriedades materiais adaptadas de humanos. Ao comparar o modelo intacto com os modificados com laminectomia e hemilaminectomia, observou-se que houve influência da hemilaminectomia na amplitude de movimento, principalmente na rotação axial contralateral ao procedimento simulado. A construção desses modelos seria o primeiro passo para aplicar o uso do método de elementos finitos para o estudo da espondilomielopatia cervical em Dogues alemães.
238

Estudo biomecânico da corpectomia lateral parcial isolada e suas associações com pediculectomia e hemilaminectomia, com e sem estabilização vertebral, em cães da raça Dachshund

ARAÚJO, Bruno Martins 16 February 2017 (has links)
Submitted by Mario BC (mario@bc.ufrpe.br) on 2018-02-23T14:11:52Z No. of bitstreams: 1 Bruno Martins Araújo.pdf: 3670671 bytes, checksum: 5567c06513fec20fdccb68ace85b0be4 (MD5) / Made available in DSpace on 2018-02-23T14:11:52Z (GMT). No. of bitstreams: 1 Bruno Martins Araújo.pdf: 3670671 bytes, checksum: 5567c06513fec20fdccb68ace85b0be4 (MD5) Previous issue date: 2017-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / The objective of this study was to compare the levels of displacement versus force in techniques of partial lateral corpectomy (PLC), PLC associated with pediculectomy and PLC associated with pediculectomy and hemilaminectomy, with and without vertebral stabilization, during rotational movements, flexion, extension, lateral flexion and axial compression, to establish whether there is significant difference between these techniques in the referred breed. When vertebral stabilization was not performed, in all analyzes, the means of displacement were lower in the assessment of normal vertebra, followed by increases in the means of PLC, PLC associated with pediculectomy and hemilaminectomy. In the evaluation of the differences between the means of each technique in relation to the evaluation performed before the decompression procedures, there was an increase in the means concomitantly with an increase in the number of associated decompression procedures. In the analysis of the force versus displacement curve, there was an increase of the neutral zone in the flexion, lateral flexion and rotation movements after PLC and in the associations with the different decompression techniques. When analyzing the influence of vertebral stabilization, the mean values were higher in the evaluation of the intact vertebra and lower after the PLC, increasing the degree of displacement as it was associated with decompression techniques and vertebral stabilization in the variables axial compression, flexion, right and left lateral flexion. In the other parameters, the values were variable. In comparison between the techniques with and without pedicular screw, the means were higher when only the decompression procedures were performed and smaller after the stabilization with pedicular screws. The results suggested that spinal stabilization is not necessary in Dachshund dogs submitted to PLC and PLC associated with pediculectomy. However, PLC associated with pediculectomy and hemilaminectomy in this type of patients should be performed with caution, due to a significant increase in the range of motion. When this association is required, vertebral stabilization is indicated and was efficient in maintaining the vertebral displacement close to the values of normal displacement of intact vertebra in Dachshund dogs. / Objetivou-se comparar em cadáveres de Dachshunds os níveis de deslocamento versus força nas técnicas de corpectomia lateral parcial (CLP), CLP associada à pediculectomia e CLP associada à pediculectomia e hemilaminectomia, com e sem estabilização vertebral, durante a realização dos movimentos de rotação, flexão, extensão, flexão lateral e compressão axial, para estabelecer se há diferença significante entre estas técnicas na referida raça. Quando não se realizou a estabilização vertebral, em todas as análises, as médias do deslocamento foram menores na avaliação da vértebra normal, seguidas com acréscimos das médias da CLP, CLP associada à pediculectomia e após a realização da hemilaminectomia. Na avaliação das diferenças entre as médias de deslocamento de cada técnica em relação à avaliação realizada antes dos procedimentos descompressivos, houve o aumento do deslocamento concomitantemente com aumento do número de procedimentos descompressivos associados. Nas análises da curva de força versus deslocamento, houve aumento da zona neutra nos movimentos de flexão, flexão lateral e rotação após a realização da CLP e nas associações com as diferentes técnicas descompressivas. Ao analisar a influência da estabilização vertebral, o deslocamento foi maior na avaliação da vértebra intacta e menor após a realização da CLP, aumentando o grau de deslocamento conforme se associava as técnicas descompressivas e estabilização vertebral nas variáveis compressão axial, flexão, flexão lateral direita e esquerda. Nos demais parâmetros, os valores foram variáveis. Na comparação entre as técnicas sem e com uso de parafuso pediculares, as médias foram maiores quando foram realizados apenas os procedimentos descompressivos e menores após a estabilização com os parafusos pediculares. Os resultados sugeriram que a estabilização da coluna vertebral não é necessária em cães da raça Dachshund submetidos à CLP e CLP associada à pediculectomia. No entanto, a CLP associada à pediculectomia e à hemilaminectomia nesse tipo de pacientes deve ser realizada com precaução, devido ao aumento significativo na amplitude do movimento. Quando for necessária esta associação, a estabilização vertebral é indicada e foi eficiente na manutenção do deslocamento vertebral próximo dos valores de deslocamento normal da vértebra intacta em cães da raça Dachshund.
239

Adaptação cultural do instrumento "The low back pain disability owestry questionnaire" / Cross-cultural adaptation of oswerstry disability index

Vigatto, Ricardo 22 February 2006 (has links)
Orientador: Neusa Maria Costa Alexandre / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-06T13:14:18Z (GMT). No. of bitstreams: 1 Vigatto_Ricardo_M.pdf: 4076945 bytes, checksum: edca34fee371b306dd3b9984b10e2154 (MD5) Previous issue date: 2006 / Resumo: A literatura tem identificado a necessidade de utilização de instrumentos de medida padronizados e confiáveis que avaliam a dor lombar. O questionário Oswestry tomou-se um dos principais instrumentos utilizados para avaliar os distúrbios da coluna vertebral. O objetivo desse estudo foi traduzir e adaptar a versão do questionário Oswestry para o português e avaliar sua validade e confiabilidade. A adaptação cultural foi realizada de acordo com a metodologia recomendada internacionalmente, usando as seguintes fases: tradução, retro-tradução, revisão por um comitê de especialistas e pré-teste. Primeiramente, o questionário foi traduzido para o português por dois tradutores bilíngües, de uma forma independente. Posteriormente, dois outros tradutores profissionais que possuíam como língua materna o inglês, fizeram a retro-tradução independentemente um do outro. Um comitê composto por seis especialistas revisou as versões obtidas e desenvolveram a versão final do instrumento. Essa versão foi pré-testada em 40 pacientes com lombalgia. A confiabilidade foi avaliada através da estabilidade (teste-resteste) e da consistência interna. A validade foi obtida comparando-se a pontuação do Oswestry com outros instrumentos de medida: o questionário Roland-Morris, o questionário SF-36 e uma escala numérica de dor. As propriedades psicométricas da versão traduzida foram avaliadas aplicando o questionário em 120 sujeitos com dor lombar. Os resultados mostraram uma boa validade e consistência interna (Alfa de Cronbach=0,87). No teste-resteste os resultados apontaram uma alta correlação intraclasse (r=0,99). O questionário Oswestry demonstrou possuir uma moderada correlação com a dor, usando-se uma escala numérica de dor (r=0,66). Uma correlação relativamente alta foi encontrada entre as pontuações do Oswestry e do Roland-Morris (r=0,81). Houve uma correlação significante (p<0,001) entre a pontuação do Oswestry e as oito dimensões do questionário SF-36. Os coeficientes de correlação mais altos foram com a capacidade funcional (r=0,83), com a dor (r=0,58) e com os aspectos físicos (r=0,53). Este estudo demonstrou que o processo usado para a adaptação do questionário Oswestry foi realizado com sucesso e que a versão adaptada possui excelentes propriedades psicométricas / Abstract: Reports in the literature have identified a need for internationally standardized and reliable measurements to analyse back pain. The Oswestry questionnaire has become one of the principal outcome measures used in the management of spinal disorders. The objective of this study was to translate and adapt a version of the Oswestry questionnaire into Brazilian Portuguese and evaluate its reliability. The cross-cultural adaptation was performed according to the internationally recommended methodology, using the following guidelines: translation, back-translation; revision by an expert committee and pretesting. First the questionnaire was independently translated into Portuguese by two bilingual translators. Second, two other professional translators whose mother tongue was English performed a back-translation independently from one another. A committee consisting of six specialists was brought together and developed a final version. This version was pretested on 40 subjects suffering from low back pain. Reliability was estimated through stability (test-retest) and homogeneity assessment. The validity was tested comparing scores of the Oswestry with the following measures: The Roland-Morris Disability Questionnaire, the SF-36 questionnaire and a numerical pain scale. The psychometric properties of the translated version were evaluated by administering the questionnaire to 120 subjects with back pain. Results indicated good content validity and internal consistency (Cronbach alpha = 0.87). Intraclass correlation coefficient for test-retest reliability was r = 0.99. The Oswestry questionnaire showed moderate correlation with pain measure using a numerical pain scale (r = 0 66). Relatively high correlation was also found between the Oswestry and the Roland - Morris scores (r = 0.81). There was significant correlation (p< 0.001) between the Oswestry scores and the eight scales of the SF - 36 questionnaire. The highest correlation coefficients were for physical functioning (r = 0,83); bodily pain (r = 0,58) and role physical (r = 0,53). This study confirmed that the process used for adaptation of the Oswestry questionnaire was well succeeded and that this version had excellent psychometrical properties / Mestrado / Enfermagem e Trabalho / Mestre em Enfermagem
240

Purificação de oligossacarideos utilizando coluna de leito fixo de zeolitas / Oligossacarides purification using fixed bed column of zeolites

Kuhn, Raquel Cristine 13 September 2006 (has links)
Orientador: Francisco Maugeri Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-07T02:51:20Z (GMT). No. of bitstreams: 1 Kuhn_RaquelCristine_M.pdf: 869149 bytes, checksum: 29e524283c358cff48f2049cd6406f50 (MD5) Previous issue date: 2006 / Resumo: Os frutooligossacarídeos (FOS) são considerados ingredientes naturais de alimentos devido aos efeitos benéficos na proliferação de bifidobactérias no cólon humano, sendo classificados como prebióticos. Estudos recentes demonstram que a separação cromatográfica de monossacarídeos e misturas de dissacarídeos pode melhorar através da utilização de zeólitas Y, sendo também promissoras na separação de oligossacarídeos. Neste estudo, colunas com zeólitas foram utilizadas na separação de oligossacarídeos. A enzima produtora dos frutooligossacarídeos foi isolada de Rhodotorula sp., produzindo seletivamente GF2 (kestose), GF3 (nistose) e GF4 (frutofuranosilnistose). O rendimento de frutooligossacarídeos produzidos foi de 52% quando foi utilizada sacarose 50% como substrato. A separação dos frutooligossacarídeos foi realizada através de coluna empacotada com zeólitas Y trocadas com íons Ba2+. A eficiência de separação foi utilizada como critério para caracterizar a separação. Efeitos de temperatura (400C a 500C), quantidade de amostra injetada (1 a 3 mL), vazão (0,08 a 0,12 mL.min-1) e composição do desorvente (etanol 40 a 60%) foram analisados, através de um planejamento experimental fracionário, onde a vazão se mostrou significativa. O estudo de separação dos açúcares demonstrou que a condição mais favorável para a separação foi com duas colunas em série com etanol 60% como desorvente, temperatura de 500C, vazão de 0,08 mL.min-1 e quantidade de amostra injetada de 1 mL. Os valores de eficiência de separação foram de 0,60 para oligossacarídeos e glicose, 1,00 para oligossacarídeos e frutose, 0,22 para oligossacarídeos e sacarose, 0,43 para glicose e frutose, 0,82 para glicose e sacarose e 1,23 para frutose e sacarose / Abstract: Fructooligosaccharides (FOS) are nowadays considered natural food ingredients because of their beneficial effects in proliferating bifidobactéria in human colon; FOS are classified as prebiotics. Some recent studies show that the chromatographic separation of monosaccharides and a mixture of the disaccharides can be improved by using Y-zeolites, being promising in the separation of oligosaccharides. In this study, a column packed with zeolite was used to study the separation of oligosaccharides. The enzyme, which produces FOS from sucrose, was isolated from Rhodotorula sp., produced selectively GF2 (kestose), GF3 (nystose) and GF4 (frutofuranosyl nystose). The final yield of FOS was 52% when 50% sucrose was used as substrate. For the separation of fructooligosaccharides was used column packed with Ba2+ - exchanged Y zeolites. Efficiency of separation was used as a criterion to characterize the effectiveness of the separation. Effects of temperature (400C a 500C), amount of mixture injection (1 a 3 mL), flow rate (0,08 a 0,12 mL.min-1) and desorbent composition (ethanol 40 a 60%) were investigated, the according to a fractionary fatorial design; the flow rate was a significant factor under the response of efficiency of separation. The study of separation of sugars showed that the most favorable conditions for this separation were with utilization of two columns in series with ethanol 60% as desorbent, temperature of 500C, flow rate of 0,08mL.min-1 and amount of mixture injection of 1 mL. The values for the separation efficiency were 0,60 for oligosaccharides-glucose, 1,00 for oligosaccharides-fructose, 0,22 for oligosaccharides-sucrose, 0,43 for glucose-fructose, 0,82 for glucose-sucrose and 1,23 for fructose-sucrose / Mestrado / Mestre em Engenharia de Alimentos

Page generated in 0.0564 seconds