• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 227
  • 23
  • 1
  • Tagged with
  • 253
  • 87
  • 59
  • 51
  • 44
  • 36
  • 31
  • 31
  • 29
  • 29
  • 28
  • 27
  • 27
  • 23
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Modelagem e simulação dinâmica de colunas de destilação

Staudt, Paula Bettio January 2007 (has links)
A pesquisa acerca da modelagem de colunas de destilação não é mais uma novidade nos dias de hoje. Os primeiros trabalhos, com metodologias propostas para a solução de sistemas de separação modelados prato a prato, surgiram na década de 30. Porém, só a partir da década de 50, com o advento do computador digital, foram realizados investimentos sólidos no desenvolvimento de novos algoritmos e simuladores. Apesar deste investimento, apenas modelos simplificados eram utilizados devido à baixa capacidade de processamento. A partir da década de 70, os primeiros simuladores comerciais começaram a ser introduzidos na indústria e o desenvolvimento de modelos rigorosos não parou mais. Dentro deste contexto, este trabalho tem como objetivo o desenvolvimento de um modelo rigoroso de coluna de destilação, genérico, dinâmico e de fácil aplicação nos mais variados tipos de estudos, desde simples simulações de operação até otimizações e previsões de comportamentos de parada e partida de plantas. Ou seja, um modelo projetado para situações onde uma representação fiel do comportamento dinâmico é necessária. Os modelos gerados neste estudo foram implementados na linguagem de modelagem do simulador EMSO e fazem parte da biblioteca EML (EMSO Model Library). Esta biblioteca é distribuída no conceito de software livre, disponibilizando todos os modelos via internet e sem custo. Para a validação dos modelos desenvolvidos foram utilizados dois exemplos: uma coluna de destilação reativa com dados provenientes da literatura e uma coluna deisobutanizadora industrial da PETROBRAS com 80 pratos que separa o isobutano de uma mistura de 13 componentes. Este último problema resulta em um sistema com mais de 6300 variáveis, provando que o simulador utilizado é muito eficiente para a resolução de problemas de grande escala. Os resultados da validação foram satisfatórios, assim como o desempenho do simulador EMSO quanto à eficiência computacional e à robustez na solução do problema. / Nowadays, modeling and simulation of distillation columns are not a new research subject anymore. It was around the 1930’s that the first methodologies were proposed to solve staged separation systems. However, it was in 1950’s, with the advent of digital computers that most important investments were made for the development of new algorithms and simulators. In spite of these investments, only very simple models were used due to the low speed of the computers available at that time. In the 1970’s, the industry started to use the first commercial simulators and the development of rigorous models for distillation columns has not stopped since then. Inside this context, the main goal of this work is the development of a rigorous, generic, dynamic and easy-to-use model of distillation column to be applied on diferent targets, from operation simulations to dynamic optimizations and the prediction of the start up and shut down plant behaviour. To do so, the model must represent the dynamic performance of the unit. The models generated were implemented in the EMSO simulator environment with its own modeling language and are part of the EMSO Model Library (EML), which is distributed under the Free Software concept. In order to analyze the model performance, two examples were chosen: a reactive distillation column from the literature and an 80 tray deisobutanizer column from PETROBRAS which separates isobutane of a 13 component mixture. The solution of the last problem generates a 6300 variable system, that is used to confirm the great efficiency of EMSO to solve large scale problems. The validation results have been as satisfactory as the model prediction and the EMSO simulator performance in computational efficiency and robustness.
92

Avaliação da eficiência de pratos valvulados de dois passes com downcomer de uma coluna de destilação industrial

Invernici, Pedro Luís January 2009 (has links)
Este trabalho aborda a predição da eficiência de pratos valvulados de dois passes, de escoamento cruzado com downcomers de uma coluna de destilação industrial, através do uso de diferentes modelos com e sem o uso do método Stagnant Regions Model proposto por Lockett em 1986. Contrariando o esperado, poucos artigos foram publicados sobre as principais características de pratos valvulados e bem menos sobre eficiência de pratos valvulados de dois passes. Os resultados encontrados sugerem que a correlação de O'Connell, o modelo de Chan e Fair aplicado aos pratos valvulados de dois passes convertidos para um passe e o modelo de Chan e Fair com uso do método SRM são os que melhor predizem a eficiência de pratos valvulados de dois passes, de escoamento cruzado com downcomers, no caso estudado.Em consonância com os estudos prévios, a correlação de O'Connell subestima o valor da eficiência, mostrando-se levemente conservativa, enquanto as predições pelo uso do modelo de Chan e Fair e do modelo modificado de Chan e Fair com uso do comprimento equivalente proposto por Klemola e Ilme superestimam o valor da eficiência, mostrando-se levemente não-conservativas. / This work approaches the prediction of the efficiency of two passes, crossflow valve trays with downcomers of an industrial distillation column, through the use of different models with and without the use the Stagnant Regions Model, method proposed by Lockett in 1986.Contradicting what it could be expected, few papers were published about the main characteristics of valve trays and fewer about efficiency of two passes valve trays. The results suggest that the O'Connell's correlation, the model of Chan and Fair applied to the two passes valve trays converted for one pass valve tray and the model of Chan and Fair with SRM method are those that best predict the efficiency of two passes, crossflow valve trays with downcomers. In consonance with the previous published studies, the O'Connell'correlation underestimates the value of the efficiency, showing a slightly conservative value, while the predictions using Chan and Fair model and the modified Chan and Fair model with equivalent length proposed by Klemola and Ilme overestimates the value of the efficiency, showing a slightly non-conservative results.
93

COBET : abordagem termodinâmica para a otimização e o controle de processos

Paim, Ágata January 2013 (has links)
O aumento do custo e da demanda de energia, juntamente com a escassez de recursos não renováveis e o crescente apelo para a sustentabilidade dos processos, incentiva o desenvolvimento de equipamentos e sistemas mais eficientes mediante a otimização e o controle dos recursos energéticos disponíveis. A proposta deste trabalho consiste em estabelecer uma abordagem termodinâmica para o controle e a otimização de processos visando o aumento da eficiência na operação dos mesmos. Para tanto, foi desenvolvido um problema de controle ótimo formulado com base no critério de eficiência termodinâmica de acordo com a 2ª Lei, com o objetivo de otimizar a transição entre estados com respeito a taxa de geração de entropia do sistema, mantendo as variáveis controladas como restrições de desigualdade dependentes do tempo. A estratégia proposta, chamada COBET (controle baseado na eficiência termodinâmica), foi aplicada a uma coluna de destilação binária para controlar a pureza do destilado e do produto de fundo, manipulando a razão de refluxo e a taxa de transferência de calor do refervedor. O COBET apresentou ajuste simples, tempo computacional razoável e desempenho de controle aceitável, quando comparado com controladores convencionais. Foi proposta uma estratégia alternativa, de modo a aprimorar o COBET, chamada R-COBET, que consiste no uso de restrições adicionais que garantem que as variáveis de controle permaneçam entre o estado inicial e final. O R-COBET obteve um desempenho aceitável, menor integral do erro quadrático das variáveis de controle e maior lucro, quando comparado ao COBET. A fim de demonstrar a aplicabilidade da metodologia proposta a outras funções objetivo, uma função empírica de eficiência baseada na 1ª Lei da Termodinâmica foi determinada e utilizada no problema de controle ótimo, sujeito às mesmas restrições consideradas no controlador R-COBET. Também se aplicou a metodologia proposta a um reator CSTR com o intuito de controlar a temperatura e a concentração do produto, considerando-se o controlador na forma R-COBET, e obteve-se um desempenho similar ao do estudo da coluna de destilação. Com estas análises, concluiu-se que a metodologia proposta pode ser aplicada com sucesso a problemas de controle ótimo com estados final e inicial definidos. / The increasing demand of energy and its rising costs, in addition to the non-renewable resources depletion and to the growing interest in the sustainability in industrial processes, stimulate the development of equipment and systems that are more efficient through the control and optimization of available energy resources. The purpose of this work is to establish a thermodynamic approach to process control and optimization, in order to improve operational efficiency. To this end, it is developed in this work an optimal control problem formulated on the basis of a thermodynamic efficiency criterion, as dictated by the 2nd Law. The principle is to optimize the transition between states with respect to thermodynamic efficiency – regarded as the square of entropy generation rate – while maintaining the controlled variables as time dependent inequality constraints. The proposed strategy, called here TEBC (Thermodynamic Efficiency Based Control) was applied to a binary distillation column in order to control distillate and bottom product purities within specifications while manipulating the reflux ratio and reboiler heat transfer rate. When compared to other controllers, TEBC presented practical tuning, reasonable computational time and acceptable control performance. An alternative strategy was also proposed in order to improve TEBC, called R-TEBC, which considers additional constraints to ensure that control variables remain between the initial and final states. The R-TEBC achieved acceptable performance, smaller integral squared error in the control variables and larger profit, when compared to TEBC. In order to demonstrate the applicability of the proposed methodology to other objective functions, an empirical efficiency function was proposed for the distillation column example and used in the optimal control problem, in the form of a R-TEBC controller. Moreover, an exothermic CSTR reactor with product concentration and reactor temperature as controlled variables was also studied, using additional constraints (R-TEBC), and the results was similar to those obtained in the distillation column. With this analysis, it was concluded that the proposed methodology can be applied to optimal control problems of this kind with fixed initial and final states.
94

Estudo de estabilidade de perfis pultrudados de materiais PRFV

Pierin, Igor January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2013-07-15T22:53:43Z (GMT). No. of bitstreams: 1 222480.pdf: 2330597 bytes, checksum: 8a3afefb03ded064d7f6e0f6ba13a443 (MD5)
95

A tensão dos domínios no Caderno Letras da Folha de São Paulo (críticos, jornalistas, escritores e mercado no limiar dos anos 90)

Copetti, Rafael Zamperetti January 2005 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão. Programa de Pós-Graduação em Literatura / Made available in DSpace on 2013-07-16T00:58:22Z (GMT). No. of bitstreams: 0 / Esta dissertação é resultado da leitura, indexação e análise do caderno cultural Letras, que circulou junto às edições de sábado do jornal Folha de S. Paulo entre abril de 1989 e fevereiro de 1992. A coleção de Letras, composta por 150 fascículos, é pensada a partir de três polêmicas surgidas nas páginas do caderno as quais sintetizam importantes tensões que o permeiam: a coexistência de objetos de análise oriundos de diversos domínios; a disputa entre o crítico jornalista, o crítico acadêmico e o escritor no que tange à legitimidade para o exercício da crítica; e a relação entre Letras e o mercado editorial.
96

Práticas de informação e leitura: mediação e apropriação da informação nas cartas de leitores de um jornal popular do interior de São Paulo

Guaraldo, Tamara de Souza Brandão [UNESP] 20 March 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2013-03-20Bitstream added on 2014-06-13T21:04:29Z : No. of bitstreams: 1 guaraldo_tsb_dr_mar.pdf: 1667522 bytes, checksum: 6a4728cbc5d52220ad15b61ca33eef1b (MD5) / O presente estudo trata sobre o sujeito leitor em sua prática de informação e leitura no jornal popular BOM DIA Bauru lançado em 2005 no interior paulista. No Brasil, na primeira década do Século XXI, houve um aumento de 24,93% na circulação de jornais, com destaque para a imprensa popular. Neste sentido, essa tese propôs estudar a questão do leitor e sua prática de informação e leitura cotidiana, por isso, levantamos os dados referentes à leitura, e de modo particular, a leitura de jornal no mundo e no Brasil, assim como a própria constituição da imprensa. Dessa maneira, o objetivo principal foi conhecer o sujeito leitor em sua prática de leitura de um jornal popular, numa mediação em que efeitos de sentido são produzidos a partir da apropriação da informação. E como objetivos específicos, analisamos as práticas de leitura e informação pelo sujeito leitor na chamada Sociedade da Informação, inseridas num contexto social, político, econômico, que permitem o acesso, a circulação e o uso dos meios de leitura; investigamos a imagem (posição) que a sociedade atual produz do leitor e de sua leitura; discorremos sobre as especificidades do meio jornal enquanto meio de informação e leitura e sua inserção na história e sociedade; discutimos as abordagens sobre o leitor de um ponto de vista empírico e teórico, com vistas à análise de sua prática de leitura em um jornal específico; buscamos verificar a imagem desse leitor no jornal BOM DIA; investigamos como o leitor constitui a sua prática de leitura, o que é relevante para ele; além da posição que deve ocupar para ser o sujeito leitor do referido jornal. Para atingir os objetivos propostos, utilizamos como metodologia a técnica de Análise de Discurso. Foram selecionados textos do jornal e 30 cartas de leitores tendo como tema a mudança de layout e editorias do periódico em setembro de 2010... / The present study is intended for approaching the readers as subject in their practice of information and reading BOM DIA, a popular newspaper launched in 2005 in the inland São Paulo city of Bauru. In Brazil, in the first decade of the 21st century, there was an increasing of 24.93% in newspaper sales, especially popular publications. In this manner, this paper proposes a study on the reader and their practice of information and everyday reading. It was gathered data on reading, in particular as for reading habits in Brazil and worldwide, as well as the constitution of the press itself. The main purpose was to know the reader subject when reading a popular newspaper in some interposition in which meaning effects are produced from the appropriation of information, while the specific purposes involve analyzing the practices of reading and information in the so-called Information Society, inserted in a social, political, and economical context, which allows access, circulation and use of means of reading. We investigated the image (position) the current society produces on readers and their reading habits, explained about the specificities of the newspaper as mean of information and reading and its insertion in history and society, discussed approaches about the reader by an empirical and theoretical point of view in order to analyze the practice of reading a specific newspaper, verified the reader image in the BOM DIA newspaper, and investigated how readers constitute their reading practice and what they consider relevant, besides the position they must occupy to be the reader subject of that newspaper. In order to achieve the purposes, the methodology used is Discourse Analysis. It was selected texts from the newspaper and thirty reader’s letters whose theme was the change of layout and articles published in September 2010... (Complete abstract click electronic access below)
97

Quantificação dos metabólitos do albendazol em plasma bovino por cromatografia líquida quiral de alta eficiência, com injeção direta de amostras / Quantification of albendazole metabolites in bovine plasma by high performance liquid chromatography, using direct injection of samples

Belaz, Katia Roberta Anacleto 17 August 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:12Z (GMT). No. of bitstreams: 1 1930.pdf: 1937842 bytes, checksum: 666b965ef3ad7a4749933d0037305ce3 (MD5) Previous issue date: 2007-08-17 / Universidade Federal de Minas Gerais / This work presents the development and validation of a sensitive and enantioselective multidimensional high performance liquid chromatography (HPLC) method for determination of albendazole metabolites: albendazole sulphoxide, chiral compound, albendazole sulphone and albendazole 2-aminesulphone in bovine plasma. The compounds, (±)- albendazole sulphoxide, albendazole sulphone and 2-aminesulphone were extracted from bovine plasma using a octyl restricted access media bovine serum albumin column (C8-RAM-BSA) (5.0 x 0.46 cm i.d.) and analyzed on a chiral column containing amylose tris(3,5-dimethylphenylcarbamate) coated onto APS-Nucleosil support, as stationary phase (15.0 x 0.46 cm i.d.). The chromatographic separations of all target compounds were achieved using a mobile phase composed of phosphate buffer (0.01 M; pH 7.5):acetonitrile (60:40 v/v), flow rate of 0.5 mL/min and fluorescence detection at 290 nm and 320 nm, excitation and emission, respectively. The calibration curves were linear in the concentration range of 40.00-1280 ng/ml for each albendazole sulphoxide enantiomer, 10.0-320 ng/mL for albendazole sulphone and 10.0-320 ng/mL for albendazole 2-aminesulphone. The validated method showed linearity, precision, accuracy and adequate sensitivity, allowing it to be appropriate for pharmacokinetics studies after administration of albendazole by different routes. Moreover, two metabolites of albendazole, the albendazole sulphoxide and albendazole sulphone, were synthesized by oxidation reaction using the aquo(N-oxo of piridine) molybdenum (VI) oxo diperoxo complexe. / Este trabalho apresenta o desenvolvimento e validação de um método, sensível e enantiosseletivo, por Cromatografia Líquida Multidimensional de Alta Eficiência, para a determinação dos metabólitos do albendazol: o albendazol-sulfóxido, metabólito quiral, albendazol-sulfona e albendazol-2-aminosulfona, em plasma bovino. Os compostos (±)-albendazol-sulfóxido, albendazolsulfona e 2-amino-sulfona foram extraídos do plasma bovino através do emprego de uma coluna extratora da fase hidrofóbica C8, do tipo fase de acesso restrito de albumina sérica bovina (C8-RAM-BSA) (5,0 x 0,46 cm d.i.) e analisados em uma coluna quiral tris(3,5-dimetilfenilcarbamato) de amilose em sílica APS-Nucleosil (15,0 x 0,46 cm d.i.). A separação cromatográfica de todos os compostos de interesse foi obtida através do uso de uma fase móvel composta por tampão fosfato (0,01 M; pH 7,5):acetonitrila (60:40 v/v), com vazão de 0,5 mL/min e detecção por fluorescência, λexc e λem de 290 e 320 nm, respectivamente. As curvas de calibração foram lineares nas faixas de 40,00-1280 ng/mL para cada enantiômero do albendazol-sulfóxido, de 10,00-320,0 ng/mL para o albendazolsulfona e de 20,00-320,0 ng/mL para o albendazol-2-amino-sulfona. O método validado mostrou linearidade, precisão, exatidão e sensibilidade adequada para ser utilizado em estudos farmacocinéticos após administração do albendazol por diferentes vias. Ainda neste trabalho, foi realizada a síntese de dois dos metabólitos do albendazol, o albendazol-sulfóxido e albendazol-sulfona, através da oxidação do sulfeto com emprego do complexo aquo(N-óxido de piridina) oxo diperoxo molibdênio (VI).
98

Determinação do coeficiente cromatográfico de partição, log kw, de inibidores da bomba H+/K+ - ATPase / Determination of chromatographic partition coefficient, Log kw, of h+/k+- atpase pump inhibitors

Coimbra, Mariana 15 March 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:13Z (GMT). No. of bitstreams: 1 1927.pdf: 15439861 bytes, checksum: a37ec11edf9b18931913f9fd214dc363 (MD5) Previous issue date: 2007-03-15 / Financiadora de Estudos e Projetos / The relative retention and enantioselectivity of a homologue series constituted by five benzimidazoles, K+/H+ - ATPase pump inhibitors, was determined for three amylose tris-phenylcarbamate chiral stationary phases (CSP), under reverse and normal phase modes of elution, using ethanol as a organic modifier. It was verified similar retention profiles for the benzimidazoles homologue series on the three evaluated chiral phases, under reversed mode of elution. The switch between reversed to polar organic mode of elution, under same conditions of reversed mode, and even with a percentage of water, in the mobile phase, around 15% it is clearly observed and discussed. Also, the benzimidazoles series retention profiles on three chiral columns were similar when in the normal elution mode. However, a switch from normal to polar organic mode is slow, indicating that retention/separation mechanisms, that operate in both elution modes, are very comparable. The discrimination chiral capacity of these stationary phases was differentiated when ethanol was used as organic modifier on three elution modes. The amylose tris (3,5 dimethylphenylcarbamate) phase (CSP-2) showed high resolution (Rs) power (0.90 ¡Ü Rs ¡Ü 3.46 and 1.25 ¡Ü á ¡Ü 2.24) for omeprazole enantiomers on the three elution modes. The amylose tris [(S)-phenyethyllcarbamate) phase (CSP-3), in turn, display resolution capacity for all series of homologous enantiomers in normal mode of elution. Herein, it was established for first time a relation between normal and reversed elution mode through the isoelution point determination. Under the same percentage of ethanol, in normal mode, and water in reversed mode, the retentions are similar, when polysaccharides phases are used as chiral selectors. The enantiomeric separations of enantiomers series were carried out in multimilligram scale, and the determination of its elution order was evaluated in the three elution modes. The omeprazole enantiomers separation was performed in multimilligram scale, as a model, using the solid-phase injection technique. The results were compared with those obtained from the separation by means of classical volume injection of sample. These results are presented and discussed. / A retenção relativa e a enantiosseletividade de uma séria homóloga de cinco benzimidazóis, inibidores da bomba K+/H+-ATPase, foram determinados em três fases quirais de tris-fenilcarbamatos de amilose, no modo reverso e normal de eluição, utilizando etanol como modificador orgânico. Foram verificados perfis de retenção similares para a série homóloga de benzimidazóis, nas três fases quirais avaliadas no modo reverso de eluição. A passagem do modo reverso para o modo polar-orgânico de eluição, mesmo sob condições de modo reverso, e ainda com porcentagem de água, na fase móvel, em torno de 15% é claramente observada e discutida. Os perfis de retenção da série de benzimidazóis nas três colunas quirais também foram similares quando a eluição foi no modo normal. Entretanto, a mudança do modo normal para o modo polar-orgânico é lenta, indicando que os mecanismos de retenção/separação, que operam nos dois modos de eluição, são mais próximos. A capacidade de discriminação quiral destas fases estacionárias foi diferenciada quando se utilizou etanol como modificador orgânico nos três modos de eluição. A fase tris (3,5 dimetilfenilcarbamato) de amilose (CSP-2) mostrou alto poder de resolução (0,90 . Rs . 3,46 e 1,25 . α . 2,24) para os enantiômeros do omeprazol nos três modos de eluição. A fase tris [(S)-feniletilcarbamato] de amilose (CSP-3.1), por sua vez, apresentou capacidade de resolução para todos os enantiômeros da série homóloga no modo normal de eluição. Neste trabalho, foi estabelecida, pela primeira vez, uma relação entre o modo normal e reverso de eluição através da determinação do ponto de isoeluição. Numa mesma porcentagem de etanol, no modo normal, e de água, no modo reverso, as retenções são similares, quando se utilizam as fases de polissacarídeos como seletores quirais. Foram realizadas as separações enantioméricas dos enantiômeros da série em escala multi-miligramas, e a determinação da ordem de eluição dos mesmos foi avaliada nos três modos de eluição. A separação dos enantiômeros do omeprazol foi feita em escala multi-miligrama, como modelo, usando a técnica de injeção em fase sólida. Os resultados foram comprados com os obtidos da separação utilizando o modo clássico de injeção de amostras. Estes resultados são apresentados e discutidos.
99

Desenvolvimento de um método para qualificação simultânea de sulfametoxazol e trimetoprima em ovos de galinha utilizando a cromatografia liquida de alta eficiência bidimensional / Development of a method for simultaneous quantification of sulfamethoxazole and trimethoprim in hens eggs using bidimensional high performance liquid chromatography

Paula, Fernando Campos Costa Rodrigues de 13 April 2007 (has links)
Made available in DSpace on 2016-06-02T20:36:15Z (GMT). No. of bitstreams: 1 1911.pdf: 1095367 bytes, checksum: 719fee66f02d6939f843c1b2cf2be7d9 (MD5) Previous issue date: 2007-04-13 / Universidade Federal de Sao Carlos / This work reports the investigation of a series of bovine serum albumin (BSA) restricted access media columns (RAM) for on-line egg samples deproteinization. High exclusion percentage of egg s proteins were obtained with the three RAM BSA columns prepared (C8, C18 and phenyl) using only water as eluent. However, an increase of pressure of the chromatographic system was observed at each injection, which made unfeasible the use of these columns for direct injection of the egg samples. To prolong the life-time of the RAM-BSA columns, acetonitrile was used as a protein precipitate agent. This clean-up procedure allowed the repetitive injection of 300 µL of whole egg samples. For the simultaneous quantification of sulfamethoxazole (SMX) and trimethoprim (TMP) in eggs samples, RAM-BSA columns, in different lengths (10 and 5 cm) sizes and different chromatographic conditions were thoroughly evaluated. A bidimensional higher performance liquid chromatography configuration having a RAM C18 BSA column in the first dimension, and a C18 analytical column in the second dimension were used for simultaneous quantification of these antibiotics. The developed method showed good selectivity, accuracy and precision with limits of quantification 80 ng/mL for both compounds. Thus, the validated method is reliable and sensitive for monitoring residues in whole eggs samples. / Neste trabalho foi preparada e avaliada uma série de colunas de acesso restrito (RAM) de albumina sérica bovina (BSA) para a desproteinização on-line de amostras de ovo. As três colunas preparadas (C8, C18 e fenil) mostraram elevada percentagem de exclusão de proteínas do ovo, usando somente água como eluente. No entanto, foi observado aumento da pressão no sistema cromatográfico, a cada injeção, o que tornou inviável a injeção direta das amostras de ovo, nas condições inicialmente avaliadas. Para prolongar a vida útil das colunas RAM-BSA foi necessário a utilização de um agente de precipitação de proteínas, e dentre os agentes avaliados, acetonitrila mostrou-se o solvente mais eficiente, permitindo a injeção repetitiva de volumes de 300µL de amostras de ovo, sem alteração da pressão no sistema cromatográfico. Para o desenvolvimento do método de análise simultânea dos antibióticos sulfametoxazol (SMX) e trimetoprima (TMP) em ovos, no modo multidimensional, foram também avaliadas colunas RAM-BSA de diferentes comprimentos (10 e 5 cm) e em diferentes condições cromatográficas. O sistema, composto por uma coluna RAM C18-BSA, acoplada a uma coluna analítica C18, permitiu o desenvolvimento do método com excelente precisão, exatidão e com adequada sensibilidade. Os limites de quantificação foram de 80 ng/mL, para ambos compostos. Desta forma, o método desenvolvido poderá ser utilizado para o monitoramento de resíduos destes antibióticos em amostras de ovo.
100

Métodos para a determinação enantiomérica dos fármacos omeprazol, lansoprazol e pantoprazol em águas residuais e de estuário / Methods for the enantiomeric determination of omeprazole, lansoprazole and pantoprazole drugs in estuarine and wastewaters

Vanzolini, Kenia Lourenço 17 April 2009 (has links)
Made available in DSpace on 2016-06-02T20:36:22Z (GMT). No. of bitstreams: 1 2537.pdf: 7032312 bytes, checksum: 58b8058ab3f086b95831d5fd832c5897 (MD5) Previous issue date: 2009-04-17 / Universidade Federal de Sao Carlos / The use of restricted access media columns for direct injection of samples chemically complex is consolidated, but not for environmental samples. This work describes the conditions for exclusion of aquatic fulvic and humic acids. The analyses were performed comparing the areas obtained after direct injection of standards in a chromatography column of gel permeation (Tsk gel® G3000PWXL), and those obtained in in-line mode with the RAM-BSA. Through a calibration curve, using standards of sodium polystyrene sulfonates of different molecular weights, in order of the 18000 Da, the molecular weight of eluted fractions were determined. This work reports the development, validation and application of sensitive, precise and accuracy methods, by high performance liquid chromatography with direct injection of samples for the enantioselective determination of omeprazole, lansoprazole and pantoprazole drugs in environmental matrices (wastewater from the city of São Carlos, Brazil and estuarine water of the River Douro, Porto-Portugal). The methods were developed by multidimensional liquid chromatography using an octyl restricted access media bovine serum albumin column (RAM-BSA C8) in the first dimension for the exclusion of macromolecules and extraction of drugs. The enantiomeric separation of omeprazole was achieved in the second dimension with a chiral column, amylose tris (3,5-dimetylphenylcarbamate) coated onto APS-Nucleosil support, and the chiral column amylose tris (3,5- dimethoxyphenylcarbamate) coated onto APS-Nucleosil support it was used for simultaneous enantiomeric separation of lansoprazole and pantoprazole. Aliquots of 500μL of the samples were injected directly into the multidimensional chromatographic system with detection for ultraviolet-visible spectroscopy (UV-vis). The quantification limits obtained for the enantiomers of omeprazole were 15μg.L-1, and for the enantiomers of lansoprazole and pantoprazole 5.0 and 7.5μg.L-1, respectively. Lower quantification limits were obtained for the enantiomers of lansoprazole (0,60μg.L-1) and pantoprazole (0,40μg.L-1) by replacement of the UV-vis detector for the mass spectrometer in a multiple reaction monitoring (MRM) mode and increasing the injection volume for 1000μL. / O uso de colunas de fases de acesso restrito para injeção direta de amostras quimicamente complexas está consolidado, mas não para amostras ambientais. Este trabalho descreve as condições para exclusão de ácidos húmicos e fúlvicos aquáticos. As análises foram feitas comparando as áreas obtidas após injeção direta dos padrões numa coluna cromatográfica de permeação em gel (Tsk gel® G3000PWXL), e as obtidas no modo in-line com as colunas RAM-BSA. Através de uma curva de calibração utilizando padrões de poliestirenos sulfonatos de sódio com diferentes pesos moleculares foi determinado, na ordem de 18000 Da, o peso molecular das frações eluídas. Este trabalho reporta o desenvolvimento, validação e aplicação de métodos sensíveis, precisos e exatos, por cromatografia líquida de alta eficiência com injeção direta de amostras para a determinação enantiosseletiva dos fármacos omeprazol, pantoprazol e lansoprazol, em matrizes ambientais (água residual da cidade de São Carlos-Brasil e água do estuário do Rio Douro, Porto-Portugal). Os métodos foram desenvolvidos por cromatografia liquida multidimensional utilizando-se uma coluna de fase acesso restrito de albumina sérica bovina (RAM-BSA C8), na primeira dimensão, para exclusão das macromoléculas e para extração dos fármacos. A separação enantiomérica do omeprazol foi realizada na segunda dimensão com uma coluna quiral, tris (3,5-dimetilfenilcarbamato) de amilose em APS-Nucleosil e, para os métodos envolvendo a separação enantiomérica simultânea do lansoprazol e pantoprazol foi utilizada a coluna quiral tris (3,5- dimetoxifenilcarbamato) de amilose em APS-Nucleosil. Alíquotas de 500μL das amostras foram injetadas diretamente no sistema cromatográfico multidimensional com detecção por espectroscopia na região do ultravioletaxix visível (UV-vis). Os limites de quantificação obtidos para os enantiômeros do omeprazol foram de 15μg.L-1, e para os enantiômeros do lansoprazol e pantoprazol 5,0 e 7,5μg.L-1, respectivamente. Limites inferiores de quantificação foram obtidos para os enantiômeros do lansoprazol (0,60μg.L-1 ) e pantoprazol (0,40μg.L-1), pela substituição do detector de UV-vis por um espectrômetro de massas, no modo MRM (Multiple Reaction Monitoring), e aumento do volume de injeção para 1000μL.

Page generated in 0.0299 seconds