Mesure de distance et transmission de données inter-véhicules par phares à LED / Vehicle-to-Vehicle Visible Light Range-Finding and Communication Using the Automotive LED Lighting

Bechadergue, Bastien 10 November 2017 (has links)
En réponse aux problèmes croissants liés aux transports routiers - accidents, pollutions,congestions - les véhicules à faibles émissions, équipés de systèmes de transports intelligents (ITS)sont progressivement développés. Si la finalité de cette démarche est le véhicule entièrementautonome, on peut néanmoins s'attendre à voir d'abord sur nos routes des véhicules automatisés surdes phases de conduite spécifiques. C'est le cas du convoi automatisé, qui permet à plusieursvéhicules de rouler en convois de manière automatique et donc d'augmenter la capacité des voies decirculation tout en réduisant la consommation de carburant. La fiabilité de cet ITS repose surplusieurs briques technologiques, et en particulier sur la mesure de distance et la transmission dedonnées véhicule-véhicule (V2V).De nombreux systèmes permettent de réaliser ces deux fonctions vitales comme, par exemple, lesradars ou lidars pour la mesure de distance et la technologie IEEE 802.11p pour la communicationvéhiculaire. Si ces différents dispositifs présentent de très bonnes performances, ils sont néanmoinsparticulièrement sensibles aux interférences, qui ne cessent de se multiplier à mesure que le nombrede véhicules équipés augmente et que le trafic est dense. Pour pallier les dégradations deperformances induites par de telles situations, des technologies complémentaires pourraient donc êtreutiles. Le récent développement des diodes électroluminescentes (LED) blanches, en particulier pourl'éclairage automobile, a permis l'émergence des communications optiques visibles sans fil (VLC).Les phares à LED sont alors utilisés pour transmettre des données entre véhicules et avec lesinfrastructures. Malgré la puissance limitée de ces éclairages, plusieurs études ont montré qu'unetransmission de qualité est possible sur quelques dizaines de mètres, faisant de la VLC uncomplément particulièrement intéressant à l'IEEE 802.11p, en particulier pour les convoisautomatisés. Par analogie, on peut alors se demander si les phares ne pourraient pas être aussi utiliséspour mesurer la distance V2V.Le but de cette thèse est donc de proposer et évaluer un système dédié aux situations de convoisautomatisés qui, à partir des phares avant et arrière des véhicules, transmet des données et mesuresimultanément la distance V2V. Dans un premier temps, une étude détaillée de l'état de l'art de laVLC pour la communication V2V est effectuée afin de déterminer l'architecture de base de notresystème. La fonction de mesure de distance est ensuite ajoutée, après une revue des différentestechniques usuelles. Une fois l'architecture générale du système établie, elle est dans un premiertemps validée par des simulations avec le logiciel Simulink. En particulier, les différents paramètressont étudiés afin de déterminer leur impact sur la résolution de mesure de distance et les performancesen transmission de données, puis afin de les optimiser. Si ces simulations fournissent des indicateursimportants pour la compréhension du système, elles ne peuvent cependant remplacer les tests d'unprototype réel. L'implémentation de ce prototype est alors détaillée ainsi que les tests réalisés dansdifférentes configurations. Ces différents tests démontrent l'intérêt des solutions proposées pour lamesure de distance et la communication V2V en convois automatisés. / In response to the growing issues induced by road traffic - accidents, pollution, congestion- low-carbon vehicles equipped with intelligent transportation systems (ITS) are being developed.Although the final goal is full autonomy, the vehicles of the near future will most probably be selfdrivingin certain phases only, as in platooning. Platooning allows several vehicles to moveautomatically in platoons and thus to increase road capacity while reducing fuel consumption. Thereliability of this ITS is based on several core technologies and in particular on vehicle-to-vehicle(V2V) distance measurement and data transmission.These two vital functions can be implemented with several kinds of systems as, for instance, radars orlidars for range-finding and IEEE 802.11p-based devices for vehicular communication. Althoughthese systems provide good performances, they are very sensitive to interferences, which may be agrowing issue as the number of vehicles equipped will increase, especially in dense traffic scenario.In order to mitigate the performance degradation occurring in such situations, complementarysolutions may be useful. The recent developments of white light-emitting diodes (LED), especiallyfor the automotive lighting, has allowed the emergence of visible light communication (VLC). WithVLC, the vehicle headlamps and taillights are used to transmit data to other vehicles orinfrastructures. Despite the limited optical power available, several studies have shown thatcommunication over tens of meters are possible with a low bit error rate (BER). VLC could thus bean interesting complement to IEEE 802.11p, especially in platooning applications. By analogy, onecould wonder if the automotive lighting can also be used for V2V range-finding.The goal of this thesis is thus to propose and evaluate a system dedicated to platooning configurationsthat can perform simultaneously the V2V distance measurement and data transmission functionsusing the headlamps and taillights of the vehicles. The first step of this study is thus a detailed stateof-the art on VLC for V2V communication that will lead to a first basic architecture of our system.Then, the range-finding function is added, after a careful review of the classical techniques. Once thegeneral architecture of the system is drawn, it is validated through simulations in the Simulinkenvironment. The different degrees of freedom in the system design are especially studied, in orderfirst to evaluate their impact on the measurement resolution and the communication performances,and then to be optimized. Although these simulations provide crucial keys to understand the system,they cannot replace real prototype testing. The implementation of the prototype is thus fullydescribed, along with the results of the different experiments carried out. It is finally demonstratedthat the proposed solution has a clear interest for V2V range-finding and communication inplatooning applications.
2

Infrared and visible wireless optical technology for body sensor connectivity / Technologie optique sans fil infrarouge et visible pour la connectivité de capteurs corporels

Hoang, Thai Bang 11 July 2019 (has links)
Cette thèse est axée sur le domaine de la communication optique sans fil en intérieur pour la surveillance de la santé basée sur des capteurs corporels. L’état de l'art des communications optique sans fil dans les domaines infrarouge, visible et UV ainsi que l'analyse des systèmes liés à la santé utilisant cette technologie ont été fournis. Cela a permis de définir les objectifs et l'orientation de cette thèse. Nous avons étudié l'utilisation de la technologie infrarouge pour la transmission de données entre un capteur porté par un patient et des récepteurs situés aux coins d'un panneau d'éclairage central au plafond de l'environnement. Un lien en visible a été utilisé pour la transmission de données du luminaire vers le patient portant un smartphone équipé d'un décodeur. Les principaux défis étaient la robustesse des liens infrarouge et visible en ce qui concerne la mobilité du patient et l'impact du corps de l'utilisateur en raison de l'emplacement du capteur. Les simulations de canaux réalisées grâce à la technique de Ray-Tracing associée à la méthode de Monte-Carlo ont permis de déterminer le gain de canal qui est le paramètre principal représentant la performance. En raison de la mobilité du patient, l'analyse a été réalisée de manière statistique et en tenant compte de différents emplacements du capteur sur le corps, de la cheville à l'épaule. Les paramètres physiques et géométriques optimaux relatifs aux émetteurs et aux récepteurs afin de garantir les meilleures performances ont été déduites. Il a été démontré qu’il est essentiel de modéliser la présence du corps pour les deux liaisons montante et descendante. Les performances globales du système ont mis en évidence le potentiel des transmissions sans fil entièrement optiques pour la surveillance médicale basée sur des capteurs corporels. Cela a été en partie confirmé par des expérimentations menées à partir de prototypes de capteur communicant en infrarouge et de produits commerciaux pour la liaison en visible. / This thesis is focused on the field of indoor optical wireless communication for health monitoring based on body sensors. The state of the art of optical wireless in the infrared, visible and UV domains as well as the analysis of health related systems using this technology have been provided. This helped to define the objectives and orientations of this thesis. We have studied the use of infrared technology for data transmission between a sensor worn by a patient and receivers located at the corners of a central lighting panel at the ceiling of the environment. A link in visible was used for the transmission of data from the luminaire to the patient carrying a smartphone equipped with a decoder. The main challenges were the robustness of the infrared and visible links with regard to patient mobility and the impact of the user's body due to the location of the sensor. The channel simulations performed using the Ray-Tracing technique associated with the Monte-Carlo method allowed determining the channel gain, which is the main parameter representing the performance. Due to the patient mobility, the analysis was performed statistically and taking into account different locations of the sensor on the body, from the ankle to the shoulder. The optimal physical and geometrical parameters for transmitters and receivers to ensure the best performance have been deduced. It has been shown that it is essential to model the presence of the body for both uplink and downlink. The overall performance of the system has highlighted the potential of fully optical wireless transmissions for medical surveillance based on body sensors. This has been partly confirmed by experiments carried out from infrared communicating sensor prototypes and commercial products for the visible link.
3

Conception d’un système d’évaluation à distance de la dépense énergétique liée à une activité physique : Application à la supervision de la dépense énergétique de patients en post - AVC / Design of a remote control system for the energy expenditure related to physical activity : Application for supervision of energy expenditure of post - stroke patients

Toumieux, Pascal 17 December 2015 (has links)
Ce mémoire décrit la conception d’un dispositif, communicant sans fil, estimant la dépense énergétique liée à une activité physique (DEAP) de patients présentant de faibles niveaux d’activité physique (post-AVC) dans un milieu sensible comme les hôpitaux en associant fiabilité et sécurité. La nécessité d’une nouvelle conception s’appuie sur les résultats d’études préalables et de tests des dispositifs commercialisés dans ce domaine basés sur des accéléromètres. Pour limiter l’impact des radiofréquences, nous utilisons une technologie optique sans fil avec un émetteur porté par le patient en mouvement (plateforme existante associée à un accéléromètre et un système d’émission par diode infrarouge) et des récepteurs fixés au plafond reliés via Ethernet à un ordinateur distant permettant l’analyse des données. La probabilité de coupure d’un lien mobile en optique sans fil par transmission diffuse a été établie théoriquement en considérant un débit faible et une haute qualité de service classique dans le domaine médical. La mesure du nombre de pertes de trame durant la communication a permis de valider les performances théoriques de la technologie optique sans fil et d’établir la fiabilité de ce type de transmission infrarouge en fonction du nombre de récepteurs. Le calcul de la DEAP a été effectué à partir d’un pré-étalonnage sur deux personnes en comparant les résultats obtenus avec ceux donnés par calorimétrie et ceux donnés par un dispositif commercial. Nous avons optimisé l’étalonnage en réalisant un protocole d’essais avec un échantillon de personnes plus vaste puis avec un échantillon de onze personnes post-AVC pour valider le prototype. / This thesis describes the design of a wireless device, communicating and estimating the energy expenditure (EE) related to physical activity of patients with low levels of physical activity (post stroke) in a sensitive environment such as hospitals by combining reliability and safety. The necessity of a new device is based on the results of preliminary studies and tests of commercially available devices (for the same use) based on accelerometers. To limit the impact of radio frequencies, we use optical technology with a wireless transmitter worn by a mobile patient (existing platform combined with an accelerometer and a system of transmission with infrared diode) and receiver fixed on the ceiling and connected via Ethernet to a remote computer for data analysis. The outage probability of a mobile wireless diffuse optical transmission was theoretically established by considering a low speed and a high quality of service in the conventional medical area. Measuring the number of frame losses during communication validates the theoretical performance of the optical wireless technology and proves the reliability of this type of mobile infrared transmission according to the number of receivers. The calculation of the EE has been performed on a pre-calibration from two people by comparing the results with those given by calorimetry and those given by a commercial device. We optimized the calibration by performing a test protocol with a larger sample of people and with a sample of eleven stroke people to validate the prototype.
4

Système de télésurveillance médicale utilisant la technologie de transmission optique sans fil / Medical telesurveillance system using optical wireless communication technology

Le Bas, Clément 30 November 2017 (has links)
Cette thèse s’intéresse à l’utilisation de techniques de communications bidirectionnelles par optique sans fil pour le suivi à distance des données médicales d’un patient. Plus précisément, un lien infrarouge est considéré pour la voie montante entre un dispositif porté par le patient et plusieurs récepteurs disposés au plafond. Pour la voie descendante, on étudie un lien en lumière visible, lié aux sources d’éclairage de l’environnement. Afin d’illustrer le potentiel de la technologie pour ce type d’application, la contribution principale est l’étude des performances des canaux de communication infrarouge et visible en considérant le fait que le dispositif est porté par un patient en mouvement dans l’environnement. Après la description générale des communications par optique sans fil, les principes de base et les différentes caractéristiques sont plus particulièrement détaillés dans le domaine du visible dont le composant clé est la source LED pour la double fonction d’éclairage et de communication. La méthode utilisée pour la simulation du canal optique sans fil est basée sur un logiciel de lancer de rayons associé à la technique de Monte-Carlo qui permet une modélisation complexe du scénario de télésurveillance. L’étude du canal en visible a ainsi montré que pour prédire les performances avec fiabilité, il était important de modéliser la présence du corps du patient ainsi que les variations induites par son mouvement sur la position et l’orientation du dispositif porté. De plus, l’impact des propriétés de réflectivité optique du corps ne peut être négligé. La performance globale du lien bidirectionnel Infrarouge/Visible a ensuite été discutée en termes de probabilité de rupture pour les différentes contraintes en débit et en qualité de service associées à la plupart des applications médicales. Les différents résultats illustrent la faisabilité du scénario étudié et donc le potentiel de l’optique sans fil en alternative aux radiofréquences pour des applications de télésurveillance médicale. Pour conclure, des expérimentations en infrarouge permettent de valider les résultats du lien montant. Pour le lien descendant, un premier banc expérimental est présenté, permettant d’envisager de nombreuses perspectives. / This thesis focuses on bidirectional optical wireless communication techniques for the indoor monitoring of medical patient data. More precisely, the uplink uses infrared transmissions between a device carried by the patient and several receivers dispatched on the ceiling. For the downlink, the study deals with Visible Light Communications (VLC) using the lighting of the environment. In order to illustrate the potential of this technology for medical monitoring, the main contribution of this study consists in the evaluation of the infrared and visible channel performance considering a wearable device and patient mobility in the environment. After a general description of optical wireless communications, the thesis focuses on basic principles and characteristics of VLC, in particular the LED which is the key component allowing to provide both lighting and communication. The method used for the optical channel simulation is based on ray-tracing method associated with Monte-Carlo technique permitting a complex modeling of the studied scenario. From VLC channel study, it is shown that in order to carefully predict performance, it is important to model the presence of the patient’s body and to consider the variations induced by its movement on the position and the orientation of the wearable device. Moreover, the impact of body’s reflectivity optical properties cannot be neglected. The overall performance of the Infrared/Visible bidirectional link is then discussed in terms of outage probability for several data rates and qualities of services corresponding to several medical data types. The results highlight the feasibility of the considered monitoring scenario and the potential of optical wireless communication as an alternative for radiofrequencies regarding remote transmission. To conclude, some experimentations contribute to validation for the infrared uplink. Finally, the development of an experimental test bed on the visible downlink opens the way for future tests in order to validate the overall theoretical performances.