• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 260
  • 65
  • 20
  • 12
  • 12
  • 12
  • 12
  • 11
  • 10
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 370
  • 370
  • 260
  • 242
  • 199
  • 69
  • 57
  • 55
  • 51
  • 47
  • 45
  • 41
  • 40
  • 38
  • 37
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Estudo in vitro sobre a remineralização de lesões cariosas com o uso de materiais resinosos contendo partículas de fosfato dicálcico dihidratado funcionalizadas com TEGDMA / Remineralization potential of resin composites containing TEGDMA-functionalized calcium phosphate particles

Alania Salazar, Yvette Alania 27 April 2017 (has links)
O objetivo deste estudo foi avaliar o efeito de compósitos experimentais contendo nanopartículas de fosfato dicálcico dihidratado (DCPD) na remineralização de lesões artificiais em esmalte, em função do conteúdo de partículas de DCPD e da funcionalização destas com dimetacrilato de trietileno glicol (TEGDMA). Cinco compósitos contendo uma concentração equimolar de dimetacrilato de glicidila bisfenol A (BisGMA) e TEGDMA e 60 vol% de partículas foram manipulados. A fase inorgânica foi constituída por partículas de vidro de bário silanizadas e 0% (controle: Sem DCPD), 10% ou 20% (em volume) de partículas de DCPD, funcionalizadas (F) ou não (NF) com TEGDMA. Foram produzidas lesões artificiais subsuperficiais em fragmentos de esmalte humano mediante a imersão destes em 30 ml de solução desmineralizante (pH 5.0) por 12 dias a 37°C. Os blocos de esmalte foram divididos em 6 grupos (n=6 - 10), de acordo ao compósito aplicado na lesão: Sem DCPD, 20% DCPD NF, 20% DCPD F, 10% DCPD NF, 10% DCPD F além de um grupo sem a aplicação do compósito (Sem tratamento, ST) e expostos a ciclagem de pH (16 dias, 4 h em solução desmineralizante/pH=5 e 20 h em solução remineralizante/pH=7). As soluções foram trocadas a cada 4 dias, e coletadas para calcular o conteúdo de cálcio e fosfato mediante espectrofotometria. Os corpos de prova foram seccionados longitudinalmente e avaliados mediante microradiografia transversal (TMR). Os parâmetros analisados foram a profundidade da lesão (LD, ?m), a perda mineral integrada (?Z, vol%.?m) e a média da perda mineral (R). Foi calculado o ??Z (%, [100x(?Zinitial - ?Ztreatment)/?Zinitial]) para estimar a porcentagem de remineralização. Os dados foram submetidos a análise de variância (ANOVA) a um critério e o teste de Tukey para comparações múltiplas (alfa = 0.05). Todos os grupos restaurados mostraram recuperação mineral entre 3 a 23%. Houve diferencia significativa entre o ??Z do grupo ST e os contendo DCPD funcionalizado. No entanto, devido à alta dispersão de dados (particularmente no grupo Sem DCPD), não foi observada diferença significativa entre os grupos cuja lesão foi recoberta por compósito. Todos os grupos contendo DCPD mostraram maior recuperação mineral nos terços médio e profundo da lesão. O grupo ST mostrou desmineralização adicional. A concentração de íons cálcio e fosfato no meio de imersão não foi influenciada pela presença de DCPD, independentemente da funcionalização ou da porcentagem de DCDP no compósito. Concluiu-se que os compósitos contendo DCPD foram capazes de promover a recuperação mineral nas áreas mais profundas da lesão. / The aim of the study was to evaluate the effect of experimental composites containing dicalcium phosphate dihydrate (DCPD) nanoparticles on remineralization of artificial enamel lesions, as a function of DCPD particle content and their functionalization with triethylene glycol dimethacrylate (TEGDMA). Five composites containing equal parts (in mols) of bisphenol A glycidyl methacrylate (BisGMA) and TEGDMA and 60 vol% of filler content were manipulated. Filler phase was constituted by silanized barium glass (BG) and 0% (control: no DCPD), 10% or 20% (by volume) of DPCD particles, either functionalized (F) or non-functionalized (NF) with TEDGMA. Artificial subsurface lesions were produced in human enamel fragments by immersing them in 30 ml of demineralization solution (pH 5.0) for 12 days at 37°C. Fragments were divided into six groups (n= 6 - 10), according to the composite applied on the lesion: no DCPD, 20% DCPD NF, 20% DCPD F, 10% DCPD NF, 10% DCPD F plus an unrestored group (non treated, NT) and exposed to pH cycling (16 days, 4 h in demineralization solution/pH=5 and 20 h in remineralization solution/pH=7). Every 4 days the solutions used were changed and collected to calculate calcium and phosphate content through spectrophotometry. Specimens were sectioned longitudinally and evaluated using transverse microradiography (TMR) for lesion depth (LD, in ?m) and integrated mineral loss (?Z, vol%.?m). ??Z% [100x(?Zinitial - ?Ztreatment)/?Zinitial] was used to estimate remineralization. Data were analyzed by one-way ANOVA/Tukey test (alpha: 0.05 for all tests). All restored groups showed enamel remineralization, ranging from 3% to 23%. Significant differences were observed between NT group and groups containing functionalized DCPD. However, due to high data scattering (particularly in the group without DCPD), no statistically significant differences were found between the groups that had their lesions covered by composite. Groups containing DCPD showed more mineral recovery in the middle and the deepest third of the lesion. NT group showed further demineralization. Calcium and phosphate ion concentrations were not influenced by the DCPD particle content or its functionalization with TEGDMA. In conclusion, all composites containing DCPD particles were able to promote mineral recovery of the enamel lesion, mainly on the deeper areas of the lesion.
132

Análise da estabilidade de cor e microdureza de uma resina composta extraclara fotoativada com diferentes fontes de luz

Souza, Julianna Cristina de 20 February 2006 (has links)
Made available in DSpace on 2017-07-24T19:22:10Z (GMT). No. of bitstreams: 1 Julianna Cristiana de Souza.pdf: 923524 bytes, checksum: a0504c08fbd282509bf0da8d63b96e96 (MD5) Previous issue date: 2006-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O propósito deste estudo foi avaliar; através da aceleração de envelhecimento; a estabilidade de cor intrínseca e a microdureza Vickers da resina composta Charisma – (Heraeus-Kulzer) nas cores A2 e SL em relação à fonte de luz utilizada. Foram confeccionados 60 corpos-de-prova com 17mm de diâmetro e 1mm de espessura com auxílio de matrizes metálicas; divididos em 4 grupos: grupo 1- cor A2/ luz halógena ; grupo 2- cor SL/ luz halógena; grupo 3- cor A2/ aparelho à base de LEDs e grupo 4- cor SL/ aparelho à base de LEDs . Os espécimes foram submetidos à imersão em água deionizada a 60°C (30 dias) armazenados ao abrigo da luz. Realizaram-se duas leituras de cor uma inicial; 24 hs após a confecção dos corpos-de-prova; e uma final ao término do período experimental; após 30 dias. Utilizou-se espectrofotometria de reflectância (Espectrofotômetro Cary-Varian 100) com espectro entre 360 e 720 nm; espaço de cor CIE-Lab para a análise da alteraçào de cor. Na seqüência os corpos-de-prova foram submetidos ao teste de microdureza Vickers através do microdurômetro MMT-3 digital HMV-Shimadzu. A variável dependente microdureza foi avaliada pelo teste de Análise de Variância (ANOVA) a dois critérios; tendo como variáveis independentes: fonte de luz (halógena ou LEDs) e cor (A2 ou SL). Quando houve diferença entre os grupos pelo teste de ANOVA; o teste de Tukey foi utilizado para verificar entre quais grupos houve diferença. Para a alteração de cor; os resultados mostraram que não houve diferença estatística significativa entre os grupos estudados. No entanto; para o teste de microdureza houve diferença estatística significante para o grupo 2; apresentando os maiores valores. Concluiu-se que: o aparelho à base de LEDs utilizado neste experimento foi eficiente em proporcionar estabilidade de cor intrínseca da resina composta testada; o aparelho de lâmpada halógena proporcionou os maiores resultados de microdureza Vickers; e a cor SL apresentou melhores estabilidade de cor e microdureza quando comparada a cor A2; mesmo a maior alteração de cor encontrada neste estudo está dentro dos valores aceitáveis clinicamente.
133

ANÁLISE DE SEQUÊNCIA ALTERNATIVA PARA RESTAURAÇÃO LAMINADA:CIMENTO DE IONÔMERO DE VIDRO E RESINA COMPOSTA / Alternative sequence analysis for sandwich technique: glass ionomer cement and composite resin

Queiroz, Vania Aparecida Oliveira 06 December 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:28Z (GMT). No. of bitstreams: 1 Vania Aparecida Oliveira Queiroz.pdf: 2334313 bytes, checksum: edfd28d0622cb45ff6c0fde23b982588 (MD5) Previous issue date: 2012-12-06 / Evaluate an alternative sequence for the sandwich technique using the microtensile bond strength testing on glass-ionomer cement (GIC)-dentin and GICcomposite resin (CR) interfaces (in 7 days), and to analyze the mechanical properties (hardness and modulus of elasticity) of GIC-RC interface (in 7 days and 24 months), by the use of nano-indentation. Methods: For that, class I cavities were cut into 60 extracted human molars. The cavities were filled using two diferent sequences of closed sandwich technique with conventional glass-ionomer cement (CGIC) (KetacTM Fil Plus/3M), and resin-modified glass-ionomer cement (RMGIC) (VitrebondTM/3M).The sequences were called, convencional sequence (CS) (etching GICs surface) and alternative sequence (AS) (without etching GICs surface), and they were used in all groups RMGIC-CR, RMGIC-dentin, CGIC-CR, and CGIC-dentin. After storage period, the teeth were horizontally sectioned, along vestibular wall of the class I cavities, for the bond strength of GICs-dentin tests. For analysis of the mechanical properties and bond strength of GICs-CR, the teeth were longitudinally sectioned.The specimens intended for mechanical properties testing have been removed from the sandwich restorations center areas. For the adhesion tests, the beams were aligned, and attached to a jig employing the active gripping method and stressed in tension (MPa). For the mechanical test, the specimens were embedded, and polished, and submitted to nano-indentation (GPa). The data were analyzed by Kruskal-Wallis, Dunn, and Chi-square tests (p<0.05). Results: The GICRM presented better adhesion to dentin and CR, and the CGIC presented better mechanical properties. When was used the RMGIC, both sequences did not present differences in adhesion (dentin and CR), and in mechanical properties (RMGIC,interface, and CR) in 7 days and 24 months. Concerning CGIC-dentin and CGIC-CR,also did not find a significant difference between both sequences, despite the adhesion means difference CGIC-CR between the CS (0.96 MPa) and AS (5.78 MPa). The CS presented a significant number of spontaneously debonded beams at interface with the CR before testing (77.33%) than AS (16%). The mechanical properties analysis of CGIC-interface-CR, in 7 days and 24 months, showed significant differences between techniques. At seven days, no GICC-RC interface data was obtained due to deteriorating condition, while AS showed 0.42 GPa (hardness) and 7.50 GPa (modulus of elasticity) values. After 24 months, AS showed hardness and modulus of elasticity, respectively, 1.24 e 20.96 GPa (CGIC), and 0.40 e 7.05 GPa (interface), while CS showed 0.51 e 8.14 GPa (CGIC) without any interface value. Conclusion: The AS has performed a good option for laminate or sandwich technique when RMGIC was used, and it was the best option when a CGIC was used. / Avaliar uma sequência alternativa para a técnica do sanduíche pela análise da resistência adesiva por microtração nas interfaces cimento de ionômero de vidro (CIV)-dentina e CIV-resina composta (RC) (aos 7 dias) e pela análise das propriedades mecânicas (dureza e módulo de elasticidade) por nanoendentação na interface CIV-RC (aos 7 dias e 24 meses). Material e métodos: Para isto, foram preparadas cavidades de classe I em 60 molares humanos extraídos. As cavidades foram restauradas utilizando duas sequências técnicas diferentes para o sanduíche fechado: com cimento de ionômero de vidro convencional (CIVC) (KetacTM Fil Plus/3M) e com cimento de ionômero de vidro modificado por resina (CIVMR) (VitrebondTM/3M). As técnicas foram denominadas, sequência convencional (SC) (com condicionamento superficial do CIV) e sequência alternativa (SA) (sem condicionamento superficial do CIV), e empregadas em todos os grupos de CIVMRRC, CIVMR-dentina, CIVC-RC e CIVC-dentina. Após períodos de armazenamento, os dentes foram seccionados horizontalmente, ao longo da parede vestibular do preparo de classe I, para o teste de resistência adesiva CIV-dentina. Para análise das propriedades mecânicas e para o teste de resistência adesiva CIV-RC, os dentes foram seccionados longitudinalmente. Os espécimes destinados às análises das propriedades mecânicas foram retirados do centro das restaurações de sanduíche. Para o teste de resistência adesiva, os palitos foram alinhados e colados ao dispositivo da máquina de tração pelo método de fixação ativo e estressados em tensão (MPa). Para análise das propriedades mecânicas, os espécimes foram fixados com parafina no suporte de teste, polidos e submetidos a nanoendentação (GPa). Os testes Kruskal-Wallis, Dunn e Qui-Quadrado foram utilizados para análise dos dados (p<0,05). Resultados: O CIVMR demonstrou maior adesão, à dentina e à RC, e o CIVC demonstrou melhores propriedades mecânicas. Quando foi utilizado o CIVMR, as duas sequências técnicas estudadas não apresentaram diferenças na resistência adesiva (à dentina e à RC) e nas propriedades mecânicas, aos 7 dias e 24 meses. Quanto à resistência adesiva CIVC-dentina e CIVC-RC, também não houve diferenças significantes entre as sequências estudadas, apesar da diferença de médias de adesão CIVC-RC entre a SC (0,96 MPa) e SA (5,78 MPa). A SC também apresentou significante maior número de palitos deslocados espontaneamente na interface com a RC antes do teste (77,33%) que a SA (16%). A análise das propriedades mecânicas, aos 7 dias e 24 meses, demonstrou diferenças significantes entre as técnicas. Aos 7 dias, não foi possível obter valores na interface CIVC-RC na SC devido ao grau de deterioração existente enquanto a SA apresentou valores 0,42 GPa (dureza) e 7,50 GPa (módulo de elasticidade). Após 24 meses, a SA apresentou valores de dureza e módulo de elasticidade, respectivamente, 1,24 e 20,96 GPa (CIVC), e 0,40 e 7,05 GPa (interface), enquanto a SC apresentou 0,51 e 8,14 GPa (CIVC) e nenhum valor para interface.Conclusão: A SA apresentou-se como boa opção para a técnica laminada ou do sanduíche quando foi utilizado o CIVMR, e como a melhor opção quando foi utilizado o CIVC.
134

Avaliação clínica retrospectiva de restaurações diretas e indiretas com recobrimento de cúspides / A retrospective clinical evaluation of direct and indirect restorations with cuspal replacement

Berwanger, Carolina dos Santos January 2016 (has links)
Introdução: A crescente demanda por restaurações estéticas possibilitou novas escolhas de tratamento para restaurar dentes posteriores com extensa destruição coronária. Os tratamentos destes dentes podem envolver restaurações diretas com resina composta ou indiretas do tipo onlays, fabricadas com cerâmica pura ou resina composta. Porém, dados clínicos sobre a longevidade de restaurações com recobrimento de cúspides comparando as técnicas direta e indireta e os materiais resina composta e cerâmica são raros. Objetivo: Realizar uma avaliação clínica retrospectiva de restaurações diretas (resina composta) e indiretas (resina composta e cerâmica) com envolvimento de cúspides utilizando o método FDI. Metodologia: Foram avaliadas 229 restaurações em 121 pacientes (37 homens e 84 mulheres) que receberam pelo menos uma restauração direta de resina composta com recobrimento de pelo menos uma cúspide ou uma onlay de cerômero ou cerâmica entre os anos de 2003 e 2016. A avaliação visual foi feita por um examinador previamente calibrado pelo coeficiente Kappa, utilizando-se os critérios do método FDI. Os dados foram analizados através do método Kaplan-Meier, da análise de regressão de Cox multivariada e do teste Kruskal-Wallis (p <0.05). Resultados: Entre as restaurações avaliadas foram detectadas 69 falhas. As restaurações obtiveram uma taxa de sucesso de 69,9%, com taxa anual de falha (AFR) de 8,0%. Restaurações diretas de resina composta apresentaram 34,1% de falha, com AFR de 9,6%. Onlays em cerômero apresentaram 27,3% de falha, com AFR de 7,1%. Onlays de cerâmica apresentaram 28,8% de falha com AFR de 7,6%. Restaurações em homens falharam mais do que em mulheres. A causa mais comum de falha foi fratura e retenção, ocorrendo em 48 casos (69,56% das falhas). Conclusão: Restaurações diretas de resina composta e indiretas de cerômero ou cerâmica demonstraram longevidade semelhante, independente do número de cúspides envolvidas. Restaurações indiretas tiveram menor índice de falha anual do que restaurações diretas, apresentando melhor desempenho na avaliação qualitativa. Pacientes mulheres apresentaram menor prevalência e menor risco de falha de restaurações do que pacientes do sexo masculino. / Introduction: The increasing demand for aesthetic restorations had enabled new treatment choices to restore posterior teeth with extensive coronary destruction. The treatments of these teeth involve direct composite restoration or indirect onlays, made with ceramic or composite. However, clinical data on the longevity of cuspal restorations comparing direct or indirect techniques and the materials are rare. Objective: To perform a retrospective clinical evaluation of direct restorations (composite resin) and indirect restorations (composite resin and ceramics) with cuspal involvement using the FDI criteria. Methodology: 229 restorations were evaluated in 121 patients (37 men and 84 women) who received at least one direct composite restoration with envolvement of at least one cusp or ceramic and composite onlays among the years 2003 and 2016. The visual evaluation was done by an examiner previous calibrated by the Kappa coefficient, using the FDI criteria. Data were analyzed by the Kaplan-Meier method, multivariated Cox regression analysis and Kruskal-Wallis test (p<0.05). Results: Among the evaluated restorations, 69 failures were detected. Restorations achieved a survival rate of 69.9%, with annual failure rate (AFR) of 8.0%. Direct composite restorations presented a 34.1% failure, with AFR of 9.6%. Composite onlays presented 27.3% of failure, with AFR of 7.1%. Ceramic onlays showed a 28.8% failure rate with AFR of 7.6%. Restorations in men have failed more than in women. The most common reason for failure was fracture of the material and retention, occuring in 48 cases (69.56% of failures). Conclusion: Direct and indirect restorations showed similar longevity, regardless of the number of cusps involved. Indirect restorations had lower annual failure rate than direct restorations, presenting better performance in the qualitative analisys. Female patients presented lower prevalence and lower risk of failure of restorations than male.
135

Estudo da dureza e do grau de conversão de resinas compostas: efeito de fonte de luz e material

Ribeiro, Benícia Carolina Iaskieviscz [UNESP] 23 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:05Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-03-23Bitstream added on 2014-06-13T19:40:56Z : No. of bitstreams: 1 ribeiro_bci_dr_arafo.pdf: 5110465 bytes, checksum: 9456c5ff12e39d6e87024eccdba81454 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A evolução dos materiais odontológicos, a interação de resinas compostas e aparelhos fotopolimerizadores motivaram a realização deste estudo. Foram selecionadas quatro resinas compostas fotopolimerizáveis indicadas para restaurações diretas, sendo três microhíbridas: Vit-l-escenceTM (Ultradent®), Amelogen® Plus (Ultradent®) e Opallis (FGM) e outra de nanopartículas: FiltekTM Z350 (3M ESPE Dental Products), todas indicadas para dentina e na cor A2. Construiram-se corpos-de-prova com dimensões de 4 mm de diâmetro e 2 mm de profundidade (ISO 4049), os quais foram polimerizados por diferentes aparelhos fotoativadores. Para o primeiro estudo, utilizou-se o Led Ultra Lume Led 2 (Ultradent®) e uma luz halógena (Ultralux - Dabi Atlante), esta com diferentes ponteiras condutoras de luz. Decorridas 24 horas, os corpos-de-prova foram submetidos ao ensaio de dureza utilizando-se um aparelho MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA), com o qual foram realizadas quatro aferições na superfície do topo da amostra (dureza 1) e mais quatro na superfície de base (dureza 2) oposta à fonte de luz. Para o segundo estudo, novos corpos-de-prova foram confeccionados da mesma maneira, utilizando-se a luz halógena (Ultralux Dabi Atlante) com ponteira de vidro, um LED de terceira geração (Ultra Lume Led 5 Ultradent®) e dois leds de segunda geração: Radii-Cal (SDI) e Elipar Free LightTM 2 da 3M ESPETM. Os corpos-deprova foram submetidos ao mesmo teste, em dois tempos: imediato e após 24 horas. Para a terceira pesquisa, pela qual se avaliou o grau de conversão por FT-IR, empregando-se o espectrofotômetro Nexus FT- IR, confeccionou-se do mesmo modo outros corpos-de-prova e, decorridas 24 horas, estes foram triturados e misturados com KBr para a obtenção de pastilhas. Como parâmetro, confeccionou-se mais 20 pastilhas com resinas não curadas... / Our study was motivated by the evolution of dental materials, and the interaction between composite resin and light curing units. We selected four light-curing composite resins suitable for direct restorations, in shade A2, three microhybrid (Vit-l-escenceTM - Ultradent®) (Amelogen® Plus - Ultradent ®) (Opallis - FGM) and one nanoparticles (FiltekTM Z350 - 3M ESPE Dental Products), all indicated for dentin. All specimens were built with dimensions of 4mm diameter and 2mm deep, (ISO 4049) which were irradiated by different light-curing units. For the first study, we used the Led Ultra Lume Led 2 (Ultradent®), and a halogen light (Ultralux - Dabi Atlante) with the last having different conductive tips of light. At 24 hours, samples were tested in microhardness through the device MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA) where 4 measurements were performed in the top surface (hardness 1) and 4 more in the base area (hardness 2), opposite to the source of light. For the second study, new specimens were prepared in the same way, using the Light Halogen (Ultralux Dabi Atlante) with a glass pipette, a third-generation led (Ultra Lume Led 5 Ultradent®) and two second-generation LEDs: Radii-Cal (SDI) and Elipar Free LigthTM 2 (3M ESPETM). The samples were subjected to the same test in two stages: immediate and after 24 hours. For the third study, which evaluated the degree of conversion by FT-IR, using the spectrophotometer Nexus FT-IR, samples were built in the same manner and after 24 hours they were powdered and mixed with KBr, to obtain tablets. As a parameter, 20 more tablets were prepared with uncured resin. Data were collected and subjected to statistical analysis. In the first study, it was concluded that the led device (second generation) allowed polymerization and the resulting hardness values were equivalent to the halogen unit for three of the four... (Complete abstract click electronic access below)
136

Avaliação da influência da terapia fotodinâmica antimicrobiana na alteração de cor da estrutura dentária e de uma resina composta / Influence of antimicrobial photodynamic therapy in the color change of the tooth structure and a resin composite

Lorenzetti, Camila Cruz [UNESP] 05 March 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:04Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-03-05 / O objetivo deste trabalho, dividido em dois estudos, foi avaliar: (1) a influência da terapia fotodinâmica antimicrobiana na alteração de cor da dentina utilizando azul de metileno e curcumina como fotossensibilizadores nas concentrações de 20, 40 e 60 µM e nos tempos de pré-irradiação de 2 e 5 minutos, irradiados com fonte de luz LED; e (2) a influência do mesmo tratamento antimicrobiano com os mesmos fotossensibilizadores, concentrações e tempos de pré-irradiação utilizados no estudo anterior, porém sobre alteração de cor em uma resina composta microhíbrida. No primeiro estudo foram confeccionados 130 espécimes a partir de dentes humanos extraídos, os quais foram seccionados em máquina de cortes Isomet. Após a imersão nos fotossensibilizadores, avaliou-se as alterações de cor através de um espectrofotômetro de colorimetria em quatro momentos: antes do início da imersão nas soluções dos fotossensibilizadores (L0), após imersão nos fotossensibilizadores (L1), após irradiação (L2), após 10 dias (L3), após 30 dias (L4) e após 60 dias (L5). Observou-se uma variação alta das médias de ∆E nos grupos com azul de metileno independentemente da concentração e do tempo de exposição, diminuindo a partir da leitura de 10 dias. Com os grupos com curcumina, houve uma variação inicial sem diferença significativa do controle, mantendo-se próxima a ele nas leituras seguintes. Ambos fotossensibilizadores apresentaram alterações significantes clinicamente em dentina segundo a classificação da ―National Bureau of Standards‖ (NBS), sendo a alteração com a curcumina menor que do azul de metileno. No segundo estudo foram confeccionados 130 espécimes de resina composta microhíbrida (Filtek Z250XT) utilizando uma matriz de aço (10x2mm). Após a confecção dos espécimes, estes foram imersos...(Resumo completo, clicar acesso eletrônico abaixo) / This study, divided in two studies, was to evaluate: (1) the influence of antimicrobial photodynamic therapy in color change dentin using methylene blue and curcumin as photosensitizers in concentrations of 20, 40 and 60 uM and pre irradiation times 2 to 5 minutes, irradiated with a LED light source; and (2) the effect of the same antimicrobial treatment with the same photosensitizers, concentrations and pre-irradiation times used in the previous study, but on color change in a microhybrid composite. In the first study were produced 130 specimens from extracted human teeth, which were cut in Isomet cuts machine. After immersion in the photosensitizers, the color changes were evaluated using a spectrophotometer colorimeter in four stages: before the immersion in solutions of photosensitizers (L0) after immersion in photosensitizers (L1) after irradiation (L2), after 10 days (L3) after 30 days (L4) and 60 days (L5). There was a high variation of ΔE averages of the methylene blue groups independently of the concentration and exposure time, decreasing from a reading of 10 days. With curcumin groups, there was no significant difference initial variation control, remaining next to it in the subsequent readings. Both photosensitizers showed clinically significant changes in dentin according to the classification of ―National Bureau of Standards‖ (NBS), with a lowest change to curcumin that of methylene blue. In the second study were made 130 specimens microhybrid composite resin (Filtek Z250XT) using a steel matrix (10x2mm). After preparation of the specimens, they were immersed in solutions of photosensitizers and subsequently evaluated with a spectrophotometer Colorimetry in the same color reading moments performed in the previous study (initial, after immersion, after light irradiation, after 10, 30 and 60 days). In methylene blue groups was no statistically significant difference... (Complete abstract access below)
137

Quantificação de unidades formadoras de colônias de Streptococcus mutans em restaurações oclusais e selantes em dentes mediante a técnica da moldeira. Estudo clinico cego / Counting colony forming unit of Streptococcus mutans on occlusal restorations and sealants of teeth by tray technique. Blind clinical study

Vildósola Grez, Patricio Agustin [UNESP] January 2015 (has links) (PDF)
Made available in DSpace on 2017-03-14T14:10:06Z (GMT). No. of bitstreams: 0 Previous issue date: 2015. Added 1 bitstream(s) on 2017-03-14T14:42:48Z : No. of bitstreams: 1 000874703_20170916.pdf: 127430 bytes, checksum: 6c7f9d658a64027218edeedd8022d757 (MD5) Bitstreams deleted on 2017-09-22T12:16:27Z: 000874703_20170916.pdf,. Added 1 bitstream(s) on 2017-09-22T12:17:18Z : No. of bitstreams: 1 000874703.pdf: 1294999 bytes, checksum: 1c6b907cb99545ab91c73127d7a207c0 (MD5) / As restaurações e selantes podem sofrer cárie como qualquer material, devido à possibilidade das bactérias de aderir-se a suas superfícies. Objetivo principal foi colher e quantificar (contagem) das unidades formadoras de colônias de S. mutans de forma direta pela técnica da moldeira (TR) em restaurações de resina composta (RC), amálgama (AM) e em selantes de fóssulas e fissura. Material e método: Recrutaram-se 40 pacientes para o estudo de avaliação da TR, 65 para a comparação das restaurações de AM e RC e 38 para o selante. Critérios inclusão: pacientes 18-50 anos, mínimo 28 dentes na boca, pelo menos uma restauração oclusal de RC e de AM avaliadas alfa pelo critério Ryge (Kappa 0,8), e um dente com indicação de selante. Numa primeira parte, no mesmo paciente foram realizadas amostragem de saliva, impressões de RC ou AM com a TR e a técnica toothpick (TT). Na segunda e terceira etapa num mesmo paciente foram realizadas impressões de RC ou AM com a TR e no caso de selante num mesmo dente foi realizado antes e após da aplicação. TR foi feita numa moldeira de fluoreto com ágar tripticase, extrato levedura, L-cisteína, sacarose e bacitracina (TYCSB) preparada previamente. As amostras foram incubadas a 37ºC durante 48 horas, após uma contagem de unidades formadoras de colônias (UFC) foi realizado por um operador calibrado. Os resultados foram analisados com um nível de confiança do 95%. Resultados: TR foi capaz de colher e isolar S. mutans, e ter uma correlação positiva significativa (r = 0,95) com TT. Não houve correlação significativa entre TR e grupo saliva (r = 0,47). RC tive diferença estatística significativa com maior número de UFC de S. mutans do que AM (p< 0,05). A mediana de UFC/cm2 foi de 111,00 para antes aplicação de selante e 22,00 após aplicação(p< 0,05). Conclusões : TR pode colher UFC de S. mutans desde as superfícies ... (Resumo completo, clicar acesso eletrônico abaixo) / The restorations suffer secondary decay as anything material, because of the possibility of bacteria from adhering to theirs surfaces. Therefore the aim of the study is quantified (count) the colonies forming units (CFU) of S. mutans by tray technique in resin composite (RC), amalgam (AM) restorations and sealants of pits and fissures. Material and Method: 40 patients were selected to assess the tray technique, 65 patients to compare AM restorations and RC and 38 patients for sealant. Inclusion criteria: Patients 18 - 50 years old, with 28 teeth, at least one occlusal restorations with RC and AM, evaluated alfa Ryge criteria (Kappa 0.8), and at least with one teeth with indication of occlusal sealant. First study, int the same patient was taken saliva samples, for RC or AM took the impression by TR and toothpick technique (TT). The second and third parts in the same patient were taken RC and AM impression by TR and the sealant of study in the same tooth was performed before and after the sealant application. This method was performed with a fluoride tray previously loaded with a solid tripticase yeast extract cysteine sucrose and bacitracin agar. The samples were incubated at 37°C for 48 hours, after the colonies forming units (CFU) were quantified by a calibrated operator (Kappa 0.8). The results were analyzed with a confidence level of 95%. Results: TR was able to recover and isolated S. mutans, and had a positive correlation (r= 0.95) with TT. There was no significant correlation between TR and saliva (r= 0.47). RC restorations, there was statistical significant difference, with higher number of CFU of S. mutans than AM (p< 0.05). The median CFU/cm2 was 111,00 before the sealant application and 22,00 after sealant application (p< 0.05). Conclusion: The TR was be able recover CFU of S. mutans from occlusal restorations with positive correlation and significant with TT...(Complete abstract electronic access below)
138

Estudo da dureza e do grau de conversão de resinas compostas : efeito de fonte de luz e material /

Ribeiro, Benícia Carolina Iaskieviscz. January 2010 (has links)
Orientador: José Roberto Cury Saad / Banca: Margareth Oda / Banca: Anísio Lima da Silva / Banca: Celso Luiz de Angelis Porto / Banca: José Cláudio Martins Segalla / Resumo: A evolução dos materiais odontológicos, a interação de resinas compostas e aparelhos fotopolimerizadores motivaram a realização deste estudo. Foram selecionadas quatro resinas compostas fotopolimerizáveis indicadas para restaurações diretas, sendo três microhíbridas: Vit-l-escenceTM (Ultradent®), Amelogen® Plus (Ultradent®) e Opallis (FGM) e outra de nanopartículas: FiltekTM Z350 (3M ESPE Dental Products), todas indicadas para dentina e na cor A2. Construiram-se corpos-de-prova com dimensões de 4 mm de diâmetro e 2 mm de profundidade (ISO 4049), os quais foram polimerizados por diferentes aparelhos fotoativadores. Para o primeiro estudo, utilizou-se o Led Ultra Lume Led 2 (Ultradent®) e uma luz halógena (Ultralux - Dabi Atlante), esta com diferentes ponteiras condutoras de luz. Decorridas 24 horas, os corpos-de-prova foram submetidos ao ensaio de dureza utilizando-se um aparelho MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA), com o qual foram realizadas quatro aferições na superfície do topo da amostra (dureza 1) e mais quatro na superfície de base (dureza 2) oposta à fonte de luz. Para o segundo estudo, novos corpos-de-prova foram confeccionados da mesma maneira, utilizando-se a luz halógena (Ultralux Dabi Atlante) com ponteira de vidro, um LED de terceira geração (Ultra Lume Led 5 Ultradent®) e dois leds de segunda geração: Radii-Cal (SDI) e Elipar Free LightTM 2 da 3M ESPETM. Os corpos-deprova foram submetidos ao mesmo teste, em dois tempos: imediato e após 24 horas. Para a terceira pesquisa, pela qual se avaliou o grau de conversão por FT-IR, empregando-se o espectrofotômetro Nexus FT- IR, confeccionou-se do mesmo modo outros corpos-de-prova e, decorridas 24 horas, estes foram triturados e misturados com KBr para a obtenção de pastilhas. Como parâmetro, confeccionou-se mais 20 pastilhas com resinas não curadas... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Our study was motivated by the evolution of dental materials, and the interaction between composite resin and light curing units. We selected four light-curing composite resins suitable for direct restorations, in shade A2, three microhybrid (Vit-l-escenceTM - Ultradent®) (Amelogen® Plus - Ultradent ®) (Opallis - FGM) and one nanoparticles (FiltekTM Z350 - 3M ESPE Dental Products), all indicated for dentin. All specimens were built with dimensions of 4mm diameter and 2mm deep, (ISO 4049) which were irradiated by different light-curing units. For the first study, we used the Led Ultra Lume Led 2 (Ultradent®), and a halogen light (Ultralux - Dabi Atlante) with the last having different conductive tips of light. At 24 hours, samples were tested in microhardness through the device MMTT-3 Microhardness Tester (Buehler Lake Bluff, Illinois USA) where 4 measurements were performed in the top surface (hardness 1) and 4 more in the base area (hardness 2), opposite to the source of light. For the second study, new specimens were prepared in the same way, using the Light Halogen (Ultralux Dabi Atlante) with a glass pipette, a third-generation led (Ultra Lume Led 5 Ultradent®) and two second-generation LEDs: Radii-Cal (SDI) and Elipar Free LigthTM 2 (3M ESPETM). The samples were subjected to the same test in two stages: immediate and after 24 hours. For the third study, which evaluated the degree of conversion by FT-IR, using the spectrophotometer Nexus FT-IR, samples were built in the same manner and after 24 hours they were powdered and mixed with KBr, to obtain tablets. As a parameter, 20 more tablets were prepared with uncured resin. Data were collected and subjected to statistical analysis. In the first study, it was concluded that the led device (second generation) allowed polymerization and the resulting hardness values were equivalent to the halogen unit for three of the four... (Complete abstract click electronic access below) / Doutor
139

Avaliação comparativa de resinas compostas fluidas em relação a resistência à abrasão (escovação simulada). / Abrasion resistance of flowable resin composites by comparative analysis of simulated toothbrushing.

Fernanda Cristina Pimentel Garcia 02 March 2001 (has links)
O presente estudo procurou analisar, através de um teste de abrasão in vitro por escovação simulada, a perda de massa e a alteração da rugosidade superficial em resinas compostas "fluidas" e resinas compostas controles. As marcas comerciais utilizadas foram: Aeliteflo-Bisco (A), Natural Flow-DFL (N), Wave-SDI (W), Flow-It Lf-Jeneric/Pentron (FLf) e Flow-It-Jeneric/Pentron (F). Uma resina composta de partículas híbridas Z100-3M (Z) e uma de micropartículas Silux Plus-3M (S) foram utilizadas como controle. Foram confeccionados 84 corpos-de-prova, de 5mm de diâmetro e 3mm de espessura, sendo 12 para cada marca comercial utilizada. Para o acabamento e o polimento dos corpos-de-prova foram utilizados discos Sof-Lex (3M) nas granulações fina (cor azul média) e superfina (cor azul claro), por tempo médio de 15/20 segundos, para cada granulação, em baixa velocidade. Para os ensaios de abrasão, foi utilizada uma máquina apropriada associada à escova Colgate Classic Infantil (Colgate-Palmolive) de cerdas macias e solução do creme dental, Colgate Proteção Anticáries com MFP (Colgate-Palmolive), diluído em água deionizada na proporção de 1:2. No teste in vitro, foram realizados aproximadamente100.000 ciclos. A determinação do desgaste dos materiais foi verificada pela quantidade de massa perdida após os ensaios, com a utilização de uma balança analítica Sartorius. A rugosidade foi determinada quantitativamente na superfície dos corpos-de-prova, com o auxílio de um rugosímetro Hommel Tester T 1000, comparando a diferença obtida após os testes de escovação e, qualitativamente, por microscopia eletrônica de varredura. Os resultados foram analisados pela variância a um critério ANOVA e pelo Teste de Tukey com p<0,05. Pelo coeficiente de Pearson não foi verificada correlação (r=-0,0296) entre porcentagem de perda de massa e rugosidade de superfície. Os materiais não apresentaram diferenças estatisticamente significantes quanto à alteração de massa, somente quanto à rugosidade superficial. A resina A apresentou a maior alteração de massa, (3,77%), seguida da resina de micropartículas S (3,04%). Em contrapartida, a resina híbrida convencional Z apresentou a menor alteração de massa (1,29%), ficando o restante das resinas "fluidas" com alteração intermediária a estas três resinas. A maior alteração de rugosidade foi verificada para a resina W (1,1720mm), com diferenças estatisticamente significantes em relação às outras resinas testadas: S (0,2749mm), Z (0,2495mm), FLf (0,1597mm), F (0,1217mm), N (0,0620mm) e A (0,0505mm). / This research aimed to assess the wear of flowable resin composites through an in vitro simulated toothbrushing abrasion test. The weight loss and surface roughness analysis were performed using five commercial brands: Aeliteflo, Flow-It, Flow-It Lf, Natural Flow and Wave. Hybrid Z-100 and Microfilled Silux Plus composites have been included as controls. Twelve samples (discs) of each material were prepared with 5mm thickness and 3mm in diameter. The test was performed up to 100.000 cicles with an appropriate machine containing soft bristles tips, dentifrice solution and deionized water in order to simulate toothbrushing. The weight loss was determined by the differences between the initial and final weights ( before and after toothbrushing) using a Sartorius analytical scale. After 5 readings, in a T 1000 Hommel testing machine, the evaluation of surface roughness was obtained by the differences between initial and final means. The analyzed ( ANOVA and Tukey, p< 0,05) results showed that Silux Plus, Flow-it, Wave, Flow-It Lf and Natural Flow had an intermediate weight loss (3,04; 2,70; 2,19; 2,12 and 2,04% respectively). Z-100 exhibited the lowest (1,29%) weight loss, whereas Aeliteflo, the highest (3,77%). Wave showed the highest surface roughness variation (1,1720mm), statistically different from the other groups, which exhibited the following differences: Silux Plus (0,2749mm), Z-100 (0,2495mm), Flow-it Lf (0,1597mm), Flow-It (0,1217mm), Natural Flow (0,0620mm) and Aeliteflo (0,0506mm). Aeliteflo presented the highest weight loss and the lowest surface roughness difference; on the other hand, Wave showed the highest surface roughness difference and an intermediate weight loss when compared with the other tested resins.
140

Avaliação in vitro da rugosidade superficial de resinas compostas, comparando diferentes sistemas de acabamento e polimento e após a profilaxia com jato de bicarbonato / In vitro evaluation of surface roughness of different composite resins, comparing different finishing and polishing systems and after prophylaxis with bicarbonate jet

Alves, Carol Brandt 04 October 2012 (has links)
A presente pesquisa in vitro teve como objetivo avaliar a ocorrência de alterações superficiais em três resinas compostas disponíveis comercialmente quando submetidas a tratamentos de polimento e jato de bicarbonato. As alterações foram quantificadas através de análises rugosimétricas e qualificadas através de microscopia eletrônica de varredura. Foram testadas três resinas compostas:nanoparticulada Z350 (3M ESPE, Saint Paul- MN, EUA), microhíbrida Z250 (3M ESPE, Saint Paul- MN, EUA) emicroparticulada Durafill (Heraeus Kulzer, Germany). Para cada resina foram confeccionados quinze corpos de prova com o auxílio de uma matriz aço inox com 7mm de diâmetro e 3 mm de espessura em dois incrementos e fotoativadas seguindo as orientações do fabricante. Os corpos de prova foram mantidos em água destilada a 37°C por 24 horas. Em seguida foram sub divididos em três grupos de acordo com protocolos de acabamento e polimento sendo avaliados o polimento com pontas Enhance® + PoGo (Dentsply, Konstanz, Germany), pontas Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) e discos Sof Lex Pop On (3M ESPE, Saint Paul- MN, EUA). Todos os espécimes foram submetidos à ciclagem térmica de 5 a 55 °C com tempo de imersão 1 minuto por 1000 ciclos. Após a ciclagem os espécimes foram submetidos a jato de bicarbonato (equipamento Ortusonic Ortus, Campo Mourão, PR, Brasil) por 30 segundos. A rugosidade de superfície foi avaliada com o auxílio de uma aparelho rugosímetro ( Mitutoyo SJ- 201P Mitutoyo Tokyo, Japão) em três momentos, sendo a primeira leitura, baseline, realizada após 24hs da confecção dos corpos de prova. A segunda, após o polimento dos corpos de prova e a terceira, após a profilaxia com jato de bicarbonato. A rugosidade foi medida em cinco locais diferentes em cada espécime. Os resultados foram analisados levando em consideração a rugosidade média (Ra), em micrômetros (m). Posteriormente foram realizadas análises ao microscópio eletrônico de varredura. De acordo com a metodologia empregada, conclui-se que a resina que apresentou maior rugosidade de superfície foi a microparticulada (Durafill), as menores rugosidades foram observadas nas resinas compostas nanoparticulada (Z350) e microhibrida (Z250). Os discos Sof Lex Pop On e as pontas Enhance e PoGo produziram superfícies mais lisas do que o sistema de polimento com as pontas Astropol, tais resultados podem ser confirmados com a análise em Microscopia Eletrônica de Varredura (M.E.V). / This in vitro study aimed to evaluate the occurrence of surface changes in three commercially available resin composites when subjected to polishing treatments and bicarbonate jet. The changes were quantified through roughness analysis and qualified by scanning electron microscopy. We tested three composites: nanoparticulated Z350 (3M ESPE, St. Paul, MN, USA), microhybrid Z250 (3M ESPE, St. Paul, MN, USA) e microparticuladed Durafill (Heraeus Kulzer, Germany). For each resin were prepared fifteen test specimens with the aid of a stainless steel matrix with 7mm diameter and 3 mm thick and photoactivated in two increments following the manufacturer\'s instructions. The specimens were kept in water at 37 ° C for 24 hours. Then were divided into three groups according to protocols being evaluated finishing and polishing polishing tips with Enhance ® + PoGo (Dentsply, Konstanz, Germany), tips Astropol (Ivoclar Vivadent, Schaan, Lienchtenstein) and Sof Lex Pop On disks (3M ESPE, St. Paul, MN, USA). All specimens were subjected to thermal cycling 5-55 ° C with a soak time of 1 minute per 1000 cycles. After cycling the specimens underwent bicarbonate jet (Ortusonic Ortus equipment, Campo Mourao, Parana, Brazil) for 30 seconds. The surface roughness was evaluated with the aid of a machine rugosimeter (Mitutoyo Mitutoyo SJ-201P Tokyo, Japan) in three stages, with the first reading, baseline, performed 24 hours after the making of the specimens. The second, after polishing the samples and the third, after prophylaxis with bicarbonate jet. The roughness was measured at five different locations on each specimen. The results were analyzed taking into account the average roughness (Ra) in micrometers (mm). Later analyzes were performed by scanning electron microscope. According to the methodology, it is concluded that the resin with the highest surface roughness was microparticulated (Durafill), the lowest roughness was observed in nanoparticled composites (Z350) and microhybrid (Z250). The Sof Lex Pop On disks and tips Enhance and PoGo produced smoother surfaces than polishing system with tips Astropol, these results can be confirmed with the analysis in Scanning Electron Microscopy (SEM).

Page generated in 0.0716 seconds