Spelling suggestions: "subject:"computerassisted image processing"" "subject:"computer.assisted image processing""
1 |
Computer-assisted quantitative image analysis of cell proliferation, angiogenesis and stromal markers in experimental and laryngeal tumor developmentLaitakari, J. (Jaakko) 07 March 2003 (has links)
Abstract
Automated quantitative computer-assisted morphometric analysis of immunohistochemical expression of markers of neoplastic development and progression in experimentally induced and in human neoplasms showed very high sensitivity and reproducibility, allowing analysis of large numbers of cell and tissue components. Totals of 26 million pixels, 25,000 cells and 1500 vessels were examined, with a sensitivity exceeding 99% and reproducibility exceeding 99%.
The total expression of proliferating cell nuclear antigen (PCNA) and p53 increased consistently during 7H-dibenz[c, g] carbazole (DBC)-induced formation of dysplasias and squamous cell carcinomas (SCC:s) in hamster lung. In dysplasia, nuclear size and PCNA staining intensity increased; in SCC:s nuclear size decreased. In a retrospective study on archival material of human laryngeal squamous cell carcinomas, the occurrence and location of PCNA-positive cells were specifically related to the degree of differentiation. In SCC:s nuclear size decreased, while shape alterations and PCNA staining intensity increased in relation to degree of malignancy.
In DBC-induced respiratory carcinogenesis increased collagen matrix synthesis occurred prior to neoplasm development. Among squamous cell carcinomas, in well-differentiated tumors, collagen deposition increased, as did fiber size, in moderately differentiated tumors collagen synthesis and the deposition of new collagen decreased. The increase in transforming growth factor beta expression in differentiated cells and in the matrix was isoform-specific.
Increased angiogenesis in laryngeal tumor development occurred in preneoplastic states and in SCC: s, inversely related to the degree of differentiation. In well-differentiated neoplasms the vessels were lying in the direction of the BM, in moderately differentiated neoplasms vessels were lying in the direction of tumor invasion and in poorly differentiated neoplasms irregular, partly abnormal vessels intermixed with tumor cells. Small regular vessels predominated in benign conditions and large, irregular vessels in malignant conditions.
Experimental models provided the advantage of examining homogenous, well-characterized neoplasm progression without interfering with the process. Morphometric methods provided detailed information on large numbers of cells, useful for studies of tumor behavior and with potential clinical applications.
|
2 |
Signal-to-noise ratios in nuclear magnetic resonance imagingKing, Kevin Franklin. January 1983 (has links)
Thesis (Ph. D.)--University of Wisconsin--Madison, 1983. / Typescript. "January 1983"--Cover of photocopy. Two p. of original are reproduced on 1 p. of photocopy. eContent provider-neutral record in process. Description based on print version record. Includes bibliographical references (leaves 151-152).
|
3 |
Fotogrametria e Antropometria direta da região mamária / Photogrammetric and direct anthropometry of the breast regionFerrara, Soraia Francisco [UNIFESP] 28 April 2010 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-04-28 / Introdução: A documentação fotográfica vem sendo utilizada como ferramenta de avaliação das características morfológicas, tornando-se fonte de informação objetiva quando comparada à observação visual. A importância de mensurações na região mamária se deve tanto na esfera científica quanto envolvendo aspectos de origem jurídica, auxiliando desta forma, como mais um instrumento de avaliação pré e pós-operatória. A mensuração por antropometria direta é rotineiramente utilizada na prática clínica, contudo a análise por fotogrametria permite alcançar precisões centesimais. Objetivo: Comparar as medidas da região mamária obtidas por fotogrametria computadorizada e antropometria direta. Métodos: 40 voluntárias do gênero feminino com idades entre 18 a 60 anos, tiveram demarcado sobre a região mamária e braços 14 pontos, 6 anatômicos e 8 antropométricos. A união destes pontos formaram 8 segmentos lineares e 1 angular para cada hemicorpo. As voluntárias foram fotografadas de maneira padronizada, como: distanciamento, enquadramento fotográfico e escala numérica para a calibração do software. Estas fotografias foram mensuradas por meio de fotogrametria computadorizada com auxílio do software Image tool. Estes segmentos também foram avaliados de maneira padronizada por antropometria direta, utilizando-se fita métrica, compasso e transferidor. Resultados: Houve diferença significante entre as medidas de todos os segmentos obtidos quando comparado com os 2 métodos analisados. Conclusão: Não houve correspondência entre as medidas coletadas por antropometria direta e fotogrametria, entretanto a análise das medidas intra-avaliador mostrou alto valor de predição para a fotogrametria. / The standard photography documentation has been used as a tool of morphology assessment, becoming a source of objective information when compared with the visual site. The importance of the measurements in the front part of the breast area is due to scientific and juridical aspects, being another auxiliary method of evaluation before and after surgery. The measurement by direct anthropometry (measuring tape, compass …) are routinely used in clinical practice, however the analysis for photogrammetry allows accurate results. Objective: Compare breast measurements by digital photogrammetry and direct anthropometry. Methods: 40 volunteers from female gender, (age range 18-60) had their breasts and arms marked with 14 points, 6 anatomic and 8 anthropometric points. From the points were traced 8 linear segments and 1 angular to each hemi-body. The volunteers were photographed in the standard manner as positioning, framing photographic, correct perspective and scales to software calibration. The photos were then measured by computerized photogrammetry evaluated by direct anthropometry using a tape-measure, compass and protractor. Results: There were differences in all of the measurements taken using the three methods analyzed. Conclusions: There were no equivalencies between the measurements taken by direct anthropometry and computerized photogrammetry; however the analysis of intra examiner showed high predictive value for photogrammetry. / TEDE / BV UNIFESP: Teses e dissertações
|
4 |
QuantificaÃÃo de angiogÃnese corneana in vivo atravÃs de processamento de imagens digitais / In vivo quantification of corneal angiogenesis using digital image processingFrancisco Vagnaldo Fechine Jamacaru 24 November 2006 (has links)
CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior / Um programa de computador foi desenvolvido especificamente para a segmentaÃÃo e quantificaÃÃo de angiogÃnese corneana em imagens digitais capturadas in vivo. O propÃsito foi estabelecer um mÃtodo automÃtico para quantificar, de forma rÃpida, objetiva e acurada, a progressÃo temporal da resposta angiogÃnica. Desenvolveu-se ainda um modelo de angiogÃnese corneana inflamatÃria em coelhos, induzida por uma cauterizaÃÃo alcalina pontual, onde a resposta angiogÃnica foi avaliada, conforme cinco mÃtodos manuais, nos dias 3, 6, 9, 12, 15, 18 e 21 apÃs a cauterizaÃÃo, ocasiÃes em que tambÃm foram obtidas, de maneira padronizada, imagens digitais da cÃrnea. O software à composto de cinco mÃdulos, com funÃÃes especÃficas, que identificam e segmentam automaticamente os neovasos e quantificam a resposta angiogÃnica mediante a determinaÃÃo de trÃs parÃmetros principais: Ãrea de neovascularizaÃÃo, comprimento vascular total e nÃmero de vasos sangÃÃneos. Assim, o sistema dispensa a rotulaÃÃo prÃvia da neovascularizaÃÃo, propiciando, por conseguinte, o monitoramento espacial e temporal da resposta angiogÃnica in vivo. A avaliaÃÃo da validade do mÃtodo automÃtico proposto envolveu a determinaÃÃo do grau da correlaÃÃo entre cada um dos quantificadores automÃticos e os cinco parÃmetros manuais. Compreendeu ainda a comparaÃÃo do reconhecimento automÃtico dos vasos sangÃÃneos realizado pelo software em 50 subimagens com o reconhecimento manual efetuado, consensualmente, por trÃs examinadores (padrÃo-ouro), determinando-se entÃo a sensibilidade, especificidade e o coeficiente de concordÃncia kappa. Para avaliar a confiabilidade, trÃs examinadores utilizaram o mÃtodo automÃtico para analisar 50 imagens em dois momentos. A concordÃncia intra e interexaminadores foi medida pelo coeficiente de correlaÃÃo intraclasse. Para ilustrar a utilidade do mÃtodo automÃtico, delineou-se um ensaio que avaliou o efeito dos fÃrmacos prednisona, talidomida, Ãcido acetilsalicÃlico, etoricoxib e celecoxib no modelo de angiogÃnese corneana inflamatÃria. A anÃlise dos grÃficos dos quantificadores manuais e automÃticos revelou que a evoluÃÃo temporal da resposta angiogÃnica no modelo de angiogÃnese corneana inflamatÃria seguiu um padrÃo bifÃsico: crescimento exponencial atà o dia 12 (fase de proliferaÃÃo), seguido de crescimento linear atà o dia 21 (fase de maturaÃÃo). Constatou-se uma forte correlaÃÃo linear positiva estatisticamente significante entre os quantificadores automÃticos e manuais, denotando que o mÃtodo automÃtico mensurou a resposta angiogÃnica de forma anÃloga à realizada pelo mÃtodo manual. A sensibilidade do mÃtodo automÃtico foi 85,32%, enquanto sua especificidade foi 96,37%. A concordÃncia entre o reconhecimento manual e o reconhecimento automÃtico dos vasos sangÃÃneos foi classificada pela estatÃstica kappa como quase perfeita. A concordÃncia interexaminadores foi avaliada em seis situaÃÃes, sendo classificada como excelente em quatro delas e como boa nas outras duas. A concordÃncia intra-examinador foi mensurada em nove situaÃÃes, sendo classificada como boa em apenas uma e como excelente nas demais. AlÃm disso, o sistema automÃtico foi capaz de identificar diferenÃas na intensidade do efeito antiangiogÃnico dos diferentes fÃrmacos avaliados, possibilitando graduar a atividade inibitÃria em plena (prednisona), parcial (talidomida, Ãcido acetilsalicÃlico e etoricoxib) e insuficiente (celecoxib), demonstrando, assim, o seu valor como mÃtodo para anÃlise quantitativa de angiogÃnese. Portanto, tais dados demonstram que o sistema automÃtico proposto constitui um mÃtodo de quantificaÃÃo de angiogÃnese acurado e reprodutÃvel. / A software was developed specifically for segmentation and quantification of corneal angiogenesis in digital images acquired in vivo. The purpose was to establish an automatic method to quantify the corneal progression of the neovascular response in a rapid, objective and accurate manner. It was also developed a model of inflammatory corneal angiogenesis in rabbits induced by a punctual alkaline cauterization. Angiogenic response was evaluated at days 3, 6, 9, 12, 15, 18 and 21 after cauterization. At these occasions, digital images of cornea were also captured in a standardized fashion. The software is composed of five modules, each with specific functions, which automatically identify and segment the neovessels and quantify the neovascular response through the calculation of three main parameters: neovascularization area, total vascular length and blood vessels number. Thus, the system does not require previous enhancement of the neovascularization, so that it provides the temporal and spatial monitoring of the angiogenic response in vivo. To assess the validity of the automatic method, it was determined the correlation degree between each automatic parameters and the five manual variables. It was also evaluated by comparing automatic recognition of blood vessels performed by the software on 50 subimages with the manual recognition performed by three raters by consensus (gold-standard) and then calculating the sensitivity, specificity and kappa coefficient. To assess reliability, three raters used the automatic method for analysing 50 images at two moments. The intra and inter-raters agreement was assessed by calculating intraclass correlation coefficient. To illustrate the utility of the automatic method, it was designed an assay that evaluated the effect of prednisone, thalidomide, acetylsalicylic acid, etoricoxib and celecoxib in the model of inflammatory corneal angiogenesis. The analysis of the graphics of the manual and automatic parameters showed that the temporal progression of the neovascular response in this model followed a biphasic pattern: exponential growth until day 12 (proliferation phase), followed by linear growth until day 21 (maturation phase). It was found a statistically significant positive linear correlation between automatic and manual variables, denoting that both methods measured the angiogenic response in an analogous fashion. The sensitivity of the automatic method was 85.32% and the specificity was 96.37%. The agreement between manual and automatic recognition of blood vessels was classified as almost perfect, according to kappa statistics. The inter-raters agreement was measured in six situations and it was classified as good in two of them and as excellent in the others. Among the nine situations analysed, the intra-rater agreement was classified as good in only one of them and as excellent in the others. Furthermore, the automatic system was able to detect differences in the intensity of the antiangiogenic effect of tested drugs, allowing the inhibitory activity to be graduated as full (prednisone), partial (thalidomide, acetylsalicylic acid and etoricoxib) and insufficient (celecoxib), demonstrating, thus, its value as method for quantitative analysis of angiogenesis. Therefore, such results demonstrate that the proposed automatic system constitutes an accurate and reproducible method of angiogenesis quantification.
|
5 |
Efeito do processamento de reconstruções tridimensionais virtuais para confecção de biomodelos de prototipagem rápida: estudo experimental em mandíbulas secas humanasFerraz, Eduardo Gomes January 2009 (has links)
81f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T16:52:09Z
No. of bitstreams: 1
Dissertacao - Eduardo Gomes Ferraz.pdf: 6518404 bytes, checksum: 23aa21cb9faeb4f359532b341d12f69c (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:05:54Z (GMT) No. of bitstreams: 1
Dissertacao - Eduardo Gomes Ferraz.pdf: 6518404 bytes, checksum: 23aa21cb9faeb4f359532b341d12f69c (MD5) / Made available in DSpace on 2013-05-08T12:05:55Z (GMT). No. of bitstreams: 1
Dissertacao - Eduardo Gomes Ferraz.pdf: 6518404 bytes, checksum: 23aa21cb9faeb4f359532b341d12f69c (MD5)
Previous issue date: 2009 / O presente estudo teve como objetivo avaliar a acurácia de reconstruções tridimensionais virtuais de mandíbulas secas humanas, produzidas com diferentes protocolos de segmentação, suavização e refinamento superficial. Para isto foram construídas 80 imagens tridimensionais virtuais, provenientes do exame de tomografia computadorizada de dez mandíbulas secas, nas quais medidas lineares entre pontos anatômicos pré-determinados foram obtidas e comparadas, para uma probabilidade de erro de 5%. Os resultados obtidos demonstraram diferença significativa entre as medidas obtidas nas mandíbulas originais (padrão ouro) quando comparadas com as imagens confeccionadas a partir da segmentação outline (p<0,05) e all boundary (p<0,001) sem as ferramentas de suavização ou refinamento. Já após a utilização das diferentes formas de segmentação associadas às ferramentas de pós-processamento (suavização e refinamento), não houve diferença entre as medidas dos modelos apenas refinados ou apenas suavizados (p>0,05) com as do padrão ouro. Quando estas duas ferramentas foram aplicadas em conjunto, houve diferença estatística, quando comparadas ao padrão ouro, tanto para a segmentação outline (p<0,001), quanto para a all boundary (p<0,001). Foi avaliado também o erro dimensional dos modelos tridimensionais virtuais obtidos pelos diferentes protocolos utilizados no estudo. Esta análise demonstrou que os melhores resultados ocorreram nos modelos apenas suavizados pela segmentação outline (erro de 2,50 mm /6,52%) e os apenas refinados pela segmentação all boundary (erro de 2,37 mm /6,28%), enquanto que as maiores diferenças foram observadas nos modelos construídos sem pós-processamento, com a segmentação outline (erro de 2,50 mm /7,17%) e naqueles com as duas ferramentas de pósprocessamento a partir da segmentação all boundary (erro de 2,85 mm /7,12%). Avaliada ainda a variabilidade intra e inter-examinador constatou-se uma concordância extremamente forte em ambos os casos (p<0,05), o que demonstra a reprodutibilidade do método. / Salvador
|
6 |
Seguimento tardio de indivíduos com doença arterial coronária: ultrassom intravascular com histologia virtual para a avaliação das características constitucionais e evolutivas da aterosclerose coronária / Late outcomes of patients with coronary artery disease: intravascular ultrasound with virtual histology for the assessment of constitutional and follow-up features of coronary atherosclerosisFalcão, Breno de Alencar Araripe 28 August 2014 (has links)
Introdução: As modificações evolutivas e o impacto clínico da composição da aterosclerose coronária em pacientes sob prevenção secundária permanecem pouco conhecidos. O ultrassom intravascular com histologia virtual (VH-IVUS) permite caracterizar in vivo tais componentes. Os objetivos desse estudo foram avaliar o papel prognóstico da composição da aterosclerose da árvore coronária proximal, bem como descrever o comportamento dinâmico da placa, explorando a relação entre seus componentes e as alterações geométricas do vaso. Métodos: Conduziu-se um estudo prospectivo, observacional e unicêntrico, que incluiu pacientes encaminhados para intervenção coronária percutânea. Durante essa intervenção, realizou-se VH-IVUS tipo \"artéria inteira\" das três coronárias principais para mensurar os parâmetros geométricos do vaso (luz, membrana elástica externa, placa+média e volume percentual do ateroma) e os componentes das placas (fibrótico, fibrolipídico, núcleo necrótico e cálcio denso). Calculou-se o volume indexado de cada parâmetro por paciente, artéria e subsegmento arterial. Avaliou-se a influência dos volumes indexados da árvore coronária proximal (por paciente), sem considerar a categorização fenotípica das placas, na ocorrência de eventos cardíacos adversos maiores (MACE), definidos como óbito, infarto agudo do miocárdio e revascularização miocárdica não planejada, após 4 anos de seguimento. Em um subgrupo de pacientes, VH-IVUS volumétrico seriado foi realizado para estudar variações do ateroma nas artérias e em seus subsegmentos, testando correlações entre componentes da placa e variações geométricas do vaso. Resultados: Foram incluídos 67 pacientes com idade média de 58,9 ± 9,2 anos, 66% do sexo masculino, 42% diabéticos, 69% multiarteriais e 45% com síndrome coronária aguda recente. Obtiveram-se imagens de VH-IVUS para 255 artérias. As médias dos volumes indexados basais da árvore coronária proximal, em escala de cinza, foram: luz 8,8±2,5mm3/mm, membrana elástica externa 15,4±3,5mm3/mm e placa+média 6,6±2,0mm3/mm, com percentual de volume do ateroma de 42,8±8,9%. Quanto aos componentes do ateroma, predominou o fibrótico 2,1 ± 1,0mm3/mm (61,8 ± 6,6%), seguido por núcleo necrótico 0,6±0,4mm3/mm (16,6±6,7%), fibrolipídico 0,5±0,3mm3/mm (14,1±6,0%) e cálcio denso 0,3±0,2mm3/mm (7,6 ± 4,6%). Após 4,9 anos (intervalo interquartil: 4,5 - 5,1 anos) sob prevenção secundária, ocorreram MACE em 18 pacientes, a maioria por reestenose. Não houve correlação entre os volumes indexados basais da árvore coronária proximal e a ocorrência de MACE. VH-IVUS seriado, após 20,6 meses (intervalo interquartil: 9,1 - 23,8 meses), foi realizado em 52 pacientes. Nas artérias desses pacientes, houve redução no volume indexado de luz, redução no volume indexado de membrana elástica externa, sem alteração no volume indexado de placa+média ou no percentual de volume do ateroma. Modificações na composição da placa foram observadas, com incremento absoluto e relativo dos componentes cálcio denso (0,09±0,21mm3/mm p < 0,01; 2,2±7,1% p < 0,01) e núcleo necrótico (0,13±0,47mm3/mm p < 0,01; 3,0 ± 10,9% p < 0,01), redução relativa do componente fibrolipídico (-0,05 ± 0,81mm3/mm p=0,37; -3,7 ± 10,3% p < 0,01) sem variação do componente fibrótico (-0,04 ± 1,00mm3/mm p=0,62; -1,6 ± 13,3% p=0,12). Nos subsegmentos arteriais, a composição basal da placa correlacionou-se com a resposta de remodelamento do vaso. A quantidade total de volume indexado basal dos componentes não calcificados correlacionou-se positivamente com a resposta de remodelamento constrictiva do vaso, que ocorreu menos frequentemente em diabéticos e associou-se a maior incremento do componente cálcio denso durante a evolução. Conclusão: Em coronarianos sob prevenção secundária, a composição média da aterosclerose na árvore coronariana proximal não se associou a ocorrência de eventos cardíacos adversos maiores. O comportamento dinâmico do ateroma foi compatível com estabilização da doença, ocorrendo variação não significativa na quantidade de placa, redução luminal associada a remodelamento negativo do vaso e modificação nos constituintes da placa com desvio de um \"perfil fibrolipídico para um mais calcificado\". A quantidade basal de componentes não calcificados da placa modulou as alterações geométricas direcionadas para o remodelamento constrictivo do vaso / Background: Clinical impact of coronary atherosclerosis composition and their modifications related to secondary prevention remains not well known. Virtual histology intravascular ultrasound (VH-IVUS) allows in vivo characterization of atherosclerotic plaque components. The aim of this study was to evaluate the prognostic value of atherosclerotic plaque composition of proximal coronary tree and to describe the variations in atherosclerotic plaques, exploring the relations of theirs components with geometric modifications of the vessel. Methods: It was conducted a prospective observational single center study, including patients referred to percutaneous coronary intervention. During the interventional procedure, volumetric three vessel \"whole artery\" VH-IVUS was performed to measure geometric vessel (lumen, elastic external membrane, plaque+media, percent atheroma volume) and atheroma compositional parameters (fibrotic, fibrolipid, necrotic core, and dense calcium). It was computed the volumetric index of each parameter in patient, artery, and arterial subsegment level. It was tested the prediction value of the volumetric indexes of proximal coronary tree (patient level), disregarding the phenotypical categorization of plaques, in the occurrence of major adverse cardiac events (MACE) defined by death, acute myocardial infarction, and unplanned myocardial revascularization, after 4 years of follow-up. In a subgroup of patients, serial volumetric VH-IVUS was performed to evaluate the modifications of the atheroma in arteries and their subsegments, testing the correlations between plaque components and geometric variations of the vessel. Results: It was included 67 patients with mean age of 58.9 ± 9.2 yearsold, 66% male, 42% with diabetes, 69% with multivessel coronary disease, and 45% with recent acute coronary syndrome. VH-IVUS was obtained for 255 arteries. The average of volumetric indexes of proximal coronary tree was: lumen 8.8±2.5mm3/mm; elastic external membrane 15.4 ± 3.5mm3/mm; placa+media 6.6 ± 2.0mm3/mm and percent atheroma volume 42.8±8.9%. In terms of composition, the predominant component was fibrotic 2.1 ± 1,0mm3/mm (61.8 ± 6.6%), followed by necrotic core 0.6 ± 0.4mm3/mm (16.6 ± 6.7%), fibrolipid 0.5 ± 0.3mm3/mm (14.1 ± 6.0%) and dense calcium 0.3 ± 0.2mm3/mm (7.6 ± 4.6%). After a 4.9- year (interquartile interval: 4.5 - 5.1) follow-up, MACE occurred in 18 patients, mainly motivated by stent reestenosis. There was no correlation between baseline volumetric indexes of proximal coronary tree and the occurrence of MACE. Serial VH-IVUS, after 20.6 months (interquartile interval: 9.1 - 23.8 months), was performed in 52 patients. In arterial level, there was decrease in lumen index volume, reduction in elastic external membrane index volume, with no variation in placa+media index volume and percent atheroma volume. Changes in plaque composition were observed, with increase in absolute and relative dense calcium (0.09 ± 0.21mm3/mm p < 0.01; 2.2 ± 7.1% p < 0.01) and necrotic core (0.13 ± 0.47mm3/mm p < 0.01; 3.0 ± 10.9% p < 0.01), relative decrease in fibrolipid (-0.05 ± 0.81mm3/mm p=0.37; - 3.7 ± 10.3% p < 0.01), and no modification in fibrotic component (-0.04 ± 1.00mm3/mm p=0.62; -1.6 ± 13.3% p=0.12). In arterial subsegment level, baseline plaque composition correlated with remodeling response of the vessel. Total index volume of non-calcified plaque components positively correlated with a trend toward constrictive remodeling of the vessel, which occurred less frequently in diabetic patients and was associated with greater increase in dense calcium component. Conclusion: In patients with coronary artery disease treated with secondary prevention strategies, mean atherosclerotic plaque composition of the proximal coronary tree was not able to predict major adverse cardiac events. Dynamic behavior of atheroma in these patients was compatible with disease stabilization, related to quantitative plaque steadiness, lumen reduction associated with constrictive remodeling of the vessel, and modifications of plaque components with shifting from \"fibrolipid to more calcified profile\". Total non-calcified plaque components modulated geometric modifications toward constrictive remodeling of the vessel
|
7 |
Seguimento tardio de indivíduos com doença arterial coronária: ultrassom intravascular com histologia virtual para a avaliação das características constitucionais e evolutivas da aterosclerose coronária / Late outcomes of patients with coronary artery disease: intravascular ultrasound with virtual histology for the assessment of constitutional and follow-up features of coronary atherosclerosisBreno de Alencar Araripe Falcão 28 August 2014 (has links)
Introdução: As modificações evolutivas e o impacto clínico da composição da aterosclerose coronária em pacientes sob prevenção secundária permanecem pouco conhecidos. O ultrassom intravascular com histologia virtual (VH-IVUS) permite caracterizar in vivo tais componentes. Os objetivos desse estudo foram avaliar o papel prognóstico da composição da aterosclerose da árvore coronária proximal, bem como descrever o comportamento dinâmico da placa, explorando a relação entre seus componentes e as alterações geométricas do vaso. Métodos: Conduziu-se um estudo prospectivo, observacional e unicêntrico, que incluiu pacientes encaminhados para intervenção coronária percutânea. Durante essa intervenção, realizou-se VH-IVUS tipo \"artéria inteira\" das três coronárias principais para mensurar os parâmetros geométricos do vaso (luz, membrana elástica externa, placa+média e volume percentual do ateroma) e os componentes das placas (fibrótico, fibrolipídico, núcleo necrótico e cálcio denso). Calculou-se o volume indexado de cada parâmetro por paciente, artéria e subsegmento arterial. Avaliou-se a influência dos volumes indexados da árvore coronária proximal (por paciente), sem considerar a categorização fenotípica das placas, na ocorrência de eventos cardíacos adversos maiores (MACE), definidos como óbito, infarto agudo do miocárdio e revascularização miocárdica não planejada, após 4 anos de seguimento. Em um subgrupo de pacientes, VH-IVUS volumétrico seriado foi realizado para estudar variações do ateroma nas artérias e em seus subsegmentos, testando correlações entre componentes da placa e variações geométricas do vaso. Resultados: Foram incluídos 67 pacientes com idade média de 58,9 ± 9,2 anos, 66% do sexo masculino, 42% diabéticos, 69% multiarteriais e 45% com síndrome coronária aguda recente. Obtiveram-se imagens de VH-IVUS para 255 artérias. As médias dos volumes indexados basais da árvore coronária proximal, em escala de cinza, foram: luz 8,8±2,5mm3/mm, membrana elástica externa 15,4±3,5mm3/mm e placa+média 6,6±2,0mm3/mm, com percentual de volume do ateroma de 42,8±8,9%. Quanto aos componentes do ateroma, predominou o fibrótico 2,1 ± 1,0mm3/mm (61,8 ± 6,6%), seguido por núcleo necrótico 0,6±0,4mm3/mm (16,6±6,7%), fibrolipídico 0,5±0,3mm3/mm (14,1±6,0%) e cálcio denso 0,3±0,2mm3/mm (7,6 ± 4,6%). Após 4,9 anos (intervalo interquartil: 4,5 - 5,1 anos) sob prevenção secundária, ocorreram MACE em 18 pacientes, a maioria por reestenose. Não houve correlação entre os volumes indexados basais da árvore coronária proximal e a ocorrência de MACE. VH-IVUS seriado, após 20,6 meses (intervalo interquartil: 9,1 - 23,8 meses), foi realizado em 52 pacientes. Nas artérias desses pacientes, houve redução no volume indexado de luz, redução no volume indexado de membrana elástica externa, sem alteração no volume indexado de placa+média ou no percentual de volume do ateroma. Modificações na composição da placa foram observadas, com incremento absoluto e relativo dos componentes cálcio denso (0,09±0,21mm3/mm p < 0,01; 2,2±7,1% p < 0,01) e núcleo necrótico (0,13±0,47mm3/mm p < 0,01; 3,0 ± 10,9% p < 0,01), redução relativa do componente fibrolipídico (-0,05 ± 0,81mm3/mm p=0,37; -3,7 ± 10,3% p < 0,01) sem variação do componente fibrótico (-0,04 ± 1,00mm3/mm p=0,62; -1,6 ± 13,3% p=0,12). Nos subsegmentos arteriais, a composição basal da placa correlacionou-se com a resposta de remodelamento do vaso. A quantidade total de volume indexado basal dos componentes não calcificados correlacionou-se positivamente com a resposta de remodelamento constrictiva do vaso, que ocorreu menos frequentemente em diabéticos e associou-se a maior incremento do componente cálcio denso durante a evolução. Conclusão: Em coronarianos sob prevenção secundária, a composição média da aterosclerose na árvore coronariana proximal não se associou a ocorrência de eventos cardíacos adversos maiores. O comportamento dinâmico do ateroma foi compatível com estabilização da doença, ocorrendo variação não significativa na quantidade de placa, redução luminal associada a remodelamento negativo do vaso e modificação nos constituintes da placa com desvio de um \"perfil fibrolipídico para um mais calcificado\". A quantidade basal de componentes não calcificados da placa modulou as alterações geométricas direcionadas para o remodelamento constrictivo do vaso / Background: Clinical impact of coronary atherosclerosis composition and their modifications related to secondary prevention remains not well known. Virtual histology intravascular ultrasound (VH-IVUS) allows in vivo characterization of atherosclerotic plaque components. The aim of this study was to evaluate the prognostic value of atherosclerotic plaque composition of proximal coronary tree and to describe the variations in atherosclerotic plaques, exploring the relations of theirs components with geometric modifications of the vessel. Methods: It was conducted a prospective observational single center study, including patients referred to percutaneous coronary intervention. During the interventional procedure, volumetric three vessel \"whole artery\" VH-IVUS was performed to measure geometric vessel (lumen, elastic external membrane, plaque+media, percent atheroma volume) and atheroma compositional parameters (fibrotic, fibrolipid, necrotic core, and dense calcium). It was computed the volumetric index of each parameter in patient, artery, and arterial subsegment level. It was tested the prediction value of the volumetric indexes of proximal coronary tree (patient level), disregarding the phenotypical categorization of plaques, in the occurrence of major adverse cardiac events (MACE) defined by death, acute myocardial infarction, and unplanned myocardial revascularization, after 4 years of follow-up. In a subgroup of patients, serial volumetric VH-IVUS was performed to evaluate the modifications of the atheroma in arteries and their subsegments, testing the correlations between plaque components and geometric variations of the vessel. Results: It was included 67 patients with mean age of 58.9 ± 9.2 yearsold, 66% male, 42% with diabetes, 69% with multivessel coronary disease, and 45% with recent acute coronary syndrome. VH-IVUS was obtained for 255 arteries. The average of volumetric indexes of proximal coronary tree was: lumen 8.8±2.5mm3/mm; elastic external membrane 15.4 ± 3.5mm3/mm; placa+media 6.6 ± 2.0mm3/mm and percent atheroma volume 42.8±8.9%. In terms of composition, the predominant component was fibrotic 2.1 ± 1,0mm3/mm (61.8 ± 6.6%), followed by necrotic core 0.6 ± 0.4mm3/mm (16.6 ± 6.7%), fibrolipid 0.5 ± 0.3mm3/mm (14.1 ± 6.0%) and dense calcium 0.3 ± 0.2mm3/mm (7.6 ± 4.6%). After a 4.9- year (interquartile interval: 4.5 - 5.1) follow-up, MACE occurred in 18 patients, mainly motivated by stent reestenosis. There was no correlation between baseline volumetric indexes of proximal coronary tree and the occurrence of MACE. Serial VH-IVUS, after 20.6 months (interquartile interval: 9.1 - 23.8 months), was performed in 52 patients. In arterial level, there was decrease in lumen index volume, reduction in elastic external membrane index volume, with no variation in placa+media index volume and percent atheroma volume. Changes in plaque composition were observed, with increase in absolute and relative dense calcium (0.09 ± 0.21mm3/mm p < 0.01; 2.2 ± 7.1% p < 0.01) and necrotic core (0.13 ± 0.47mm3/mm p < 0.01; 3.0 ± 10.9% p < 0.01), relative decrease in fibrolipid (-0.05 ± 0.81mm3/mm p=0.37; - 3.7 ± 10.3% p < 0.01), and no modification in fibrotic component (-0.04 ± 1.00mm3/mm p=0.62; -1.6 ± 13.3% p=0.12). In arterial subsegment level, baseline plaque composition correlated with remodeling response of the vessel. Total index volume of non-calcified plaque components positively correlated with a trend toward constrictive remodeling of the vessel, which occurred less frequently in diabetic patients and was associated with greater increase in dense calcium component. Conclusion: In patients with coronary artery disease treated with secondary prevention strategies, mean atherosclerotic plaque composition of the proximal coronary tree was not able to predict major adverse cardiac events. Dynamic behavior of atheroma in these patients was compatible with disease stabilization, related to quantitative plaque steadiness, lumen reduction associated with constrictive remodeling of the vessel, and modifications of plaque components with shifting from \"fibrolipid to more calcified profile\". Total non-calcified plaque components modulated geometric modifications toward constrictive remodeling of the vessel
|
8 |
Validação de índices angiográficos e da angiotomografia computadorizada utilizando o ultrasson intravascular como padrão-ouro para quantificar a extensão da doença aterosclerótica coronariana / Validation of scoring systems derived from coronary conventional invasive and computed tomography angiography, using intravascular ultrasound as gold-standard, to estimate atherosclerotic disease extensionSilva, Rafael Cavalcante e 19 March 2015 (has links)
Introdução: A extensão da doença arterial coronariana (DAC) é um dos mais fortes preditores de eventos cardiovasculares adversos. Estratégias capazes de quantificar acuradamente a gravidade da doença coronária podem implicar em melhora na avalição prognóstica, na orientação terapêutica e na avaliação da progressão da doença. O ultrassom intracoronário (USIC) tornou-se o método padrão-ouro para quantificação da aterosclerose devido à sua habilidade em avaliar diretamente as placas ateroscleróticas. A angiotomografia coronária tem surgido como uma útil alternativa não invasiva ao USIC para avaliação de pacientes com DAC. Entretanto, pouco se sabe a respeito da sua habilidade em estimar, de modo acurado, a carga aterosclerótica coronariana global. Objetivo: Comparar diversos escores angiotomográficos que avaliam a extensão da DAC utilizando o USIC multivascular como padrão-ouro. Métodos: Pacientes com doença coronariana diagnosticada, em programação para intervenção percutânea foram incluídos prospectivamente. Pelo menos uma de três características de alto risco era necessária para inclusão: doença multiarterial, diabetes melitus e/ou síndrome coronária aguda à admissão. Todos os pacientes foram submetidos a ultrassom intracoronário multivascular e angiotomografia coronária. Escore de cálcio e cinco outros escores previamente descritos foram calculados com base na imagem da angiotomografia coronária e comparados com o volume percentual de ateroma (VPA) médio derivado do USIC. Um novo escore angiotomográfico foi criado e também comparado ao USIC. Resultados: Um total de 62 pacientes foram incluídos. Todos com exceção de um escore apresentaram baixa a moderada correlação, estatisticamente significante, com o VPA derivado do USIC. O novo escore angiotomográfico criado demonstrou a mais forte correlação com o VPA ao USIC (ρ=0,73, p < 0,001) e a maior área sob a curva ROC (estatística-C = 0,90) para predizer um VPA médio dicotomizado alto. Conclusões: Enquanto escores angiotomográficos foram capazes de estimar a carga aterosclerótica coronária global, um recém criado escore pode ser uma ferramenta útil para a quantificação da extensão da DAC em pacientes de alto risco. / Background: The extent of coronary artery disease (CAD) is one the most powerful predictors of cardiovascular outcomes. Strategies that accurately quantify coronary artery disease severity are expected to improve prognosis assessment, treatment guidance and evaluation of disease progression. Intravascular ultrasound (IVUS) has become the gold-standard method to quantify atherosclerosis due to its ability to directly analyze atherosclerotic plaques. Coronary computed tomography angiography (CTA) has emerged as a useful non-invasive alternative to IVUS for assessing patients with CAD. Nevertheless, little is known about its ability to accurately estimate global atherosclerotic burden. Objective: To compare several coronary CTA scoring systems assessing CAD extent with gold-standard multivessel intravascular ultrasound. Methods: Patients with diagnosed coronary disease scheduled for percutaneous intervention were prospectively enrolled. For all patients, coronary CTA and multivessel IVUS were obtained. Calcium score and 5 previously reported scores were calculated from coronary CTA imaging and compared to average IVUS-derived percent atheroma volume (PAV). A novel coronary CTA score was constructed and also compared to IVUS. Results: A total of 62 patients were included. All but one previously described scoring system showed a significant low-to-moderate association with IVUS-derived PAV. The newly developed \"soft plaque\" coronary CTA score demonstrated the strongest correlation with IVUS-PAV (ρ=0.73, p<0.001) and the greatest area under the ROC curve (C-statistic = 0.90) to predict a high dichotomized PAV. Conclusions: While coronary CTA scores were able to assess total atherosclerotic burden in patients with coronary disease, a newly described CTA scoring system may be a promising non-invasive tool to quantify disease extent in high-risk patients with known CAD.
|
9 |
Validação de índices angiográficos e da angiotomografia computadorizada utilizando o ultrasson intravascular como padrão-ouro para quantificar a extensão da doença aterosclerótica coronariana / Validation of scoring systems derived from coronary conventional invasive and computed tomography angiography, using intravascular ultrasound as gold-standard, to estimate atherosclerotic disease extensionRafael Cavalcante e Silva 19 March 2015 (has links)
Introdução: A extensão da doença arterial coronariana (DAC) é um dos mais fortes preditores de eventos cardiovasculares adversos. Estratégias capazes de quantificar acuradamente a gravidade da doença coronária podem implicar em melhora na avalição prognóstica, na orientação terapêutica e na avaliação da progressão da doença. O ultrassom intracoronário (USIC) tornou-se o método padrão-ouro para quantificação da aterosclerose devido à sua habilidade em avaliar diretamente as placas ateroscleróticas. A angiotomografia coronária tem surgido como uma útil alternativa não invasiva ao USIC para avaliação de pacientes com DAC. Entretanto, pouco se sabe a respeito da sua habilidade em estimar, de modo acurado, a carga aterosclerótica coronariana global. Objetivo: Comparar diversos escores angiotomográficos que avaliam a extensão da DAC utilizando o USIC multivascular como padrão-ouro. Métodos: Pacientes com doença coronariana diagnosticada, em programação para intervenção percutânea foram incluídos prospectivamente. Pelo menos uma de três características de alto risco era necessária para inclusão: doença multiarterial, diabetes melitus e/ou síndrome coronária aguda à admissão. Todos os pacientes foram submetidos a ultrassom intracoronário multivascular e angiotomografia coronária. Escore de cálcio e cinco outros escores previamente descritos foram calculados com base na imagem da angiotomografia coronária e comparados com o volume percentual de ateroma (VPA) médio derivado do USIC. Um novo escore angiotomográfico foi criado e também comparado ao USIC. Resultados: Um total de 62 pacientes foram incluídos. Todos com exceção de um escore apresentaram baixa a moderada correlação, estatisticamente significante, com o VPA derivado do USIC. O novo escore angiotomográfico criado demonstrou a mais forte correlação com o VPA ao USIC (ρ=0,73, p < 0,001) e a maior área sob a curva ROC (estatística-C = 0,90) para predizer um VPA médio dicotomizado alto. Conclusões: Enquanto escores angiotomográficos foram capazes de estimar a carga aterosclerótica coronária global, um recém criado escore pode ser uma ferramenta útil para a quantificação da extensão da DAC em pacientes de alto risco. / Background: The extent of coronary artery disease (CAD) is one the most powerful predictors of cardiovascular outcomes. Strategies that accurately quantify coronary artery disease severity are expected to improve prognosis assessment, treatment guidance and evaluation of disease progression. Intravascular ultrasound (IVUS) has become the gold-standard method to quantify atherosclerosis due to its ability to directly analyze atherosclerotic plaques. Coronary computed tomography angiography (CTA) has emerged as a useful non-invasive alternative to IVUS for assessing patients with CAD. Nevertheless, little is known about its ability to accurately estimate global atherosclerotic burden. Objective: To compare several coronary CTA scoring systems assessing CAD extent with gold-standard multivessel intravascular ultrasound. Methods: Patients with diagnosed coronary disease scheduled for percutaneous intervention were prospectively enrolled. For all patients, coronary CTA and multivessel IVUS were obtained. Calcium score and 5 previously reported scores were calculated from coronary CTA imaging and compared to average IVUS-derived percent atheroma volume (PAV). A novel coronary CTA score was constructed and also compared to IVUS. Results: A total of 62 patients were included. All but one previously described scoring system showed a significant low-to-moderate association with IVUS-derived PAV. The newly developed \"soft plaque\" coronary CTA score demonstrated the strongest correlation with IVUS-PAV (ρ=0.73, p<0.001) and the greatest area under the ROC curve (C-statistic = 0.90) to predict a high dichotomized PAV. Conclusions: While coronary CTA scores were able to assess total atherosclerotic burden in patients with coronary disease, a newly described CTA scoring system may be a promising non-invasive tool to quantify disease extent in high-risk patients with known CAD.
|
Page generated in 0.1414 seconds