• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 139
  • Tagged with
  • 139
  • 139
  • 139
  • 123
  • 118
  • 37
  • 35
  • 28
  • 28
  • 28
  • 26
  • 26
  • 25
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Estudo teórico-experimental de ligação viga-pilar com consolo metálico embutido em estruturas pré-moldadas de concreto / Estudo Teórico-Experimental de Ligação Viga-Pilar com Consolo Metálico Embutido em Estruturas Pré-Moldadas de Concreto

Bachega, Luís Augusto 14 February 2013 (has links)
Made available in DSpace on 2016-06-02T20:09:18Z (GMT). No. of bitstreams: 1 5038.pdf: 12517869 bytes, checksum: 373976ca3c8851e35a4dbd3dd53ff661 (MD5) Previous issue date: 2013-02-14 / Financiadora de Estudos e Projetos / This study aimed to analyze the structural behavior of a beam-column connection with embedded steel member for precast concrete with no current use still in Brazil. Based on the literature review about hidden corbels found in international technical references, a type of hidden corbel with embedded steel section (so called billet) was selected for this research. Although there are many different analytical models for the design of the billet within the available technical literature, the focus of this research was on the revised models found in the most recent design manuals PCI (2010) and FIB (2011). In addition to the analytical study an experimental investigation was conducted, wherein isolated column members with billet corbels were tested primarily to a full scale test of a sub-frame with two beams six meters long and with a central column assembled in cruciform shape. For the isolated model, named PI Model (Isolated steel corbel), the behavior of the steel corbel and its interaction with the column were evaluated. For the full scale test, named LI Model (connection zone model), the behavior of the connection zone and the behavior of the beam were studied interacting together. For both the theoretical and the experimental studies, the selected billet consisted of a rectangular hollow section of 200 mm x 100 mm x 10 mm in height, width and thickness, respectively. For the PI Model test, the billet showed a rigid behavior and it was capable of resist an applied load of 700 kN with no damage within the concrete of the column. For the case of LI Model, the experimental study analyzed the behavior of the whole connection zone, comprising both the steel corbel and the end of the beam near the corbel. For this case, the connection behaved as rigid until the applied shear force at the connection reached between 239,5 kN and 238,3 kN, for which the flexural stiffness of the connection acted as rigid, with fixity factors of 1.0 and 0.96, for the left and right connections, respectively. The failure of the model occurred at the cast in place topping of the composite beam when the shear force reached 473.5 kN. The comparison between the experimental results with the theoretical values demonstrated that the isolate billet showed compatible resistance with the expected but that the region of the beam top end showed premature failure due to lack of reinforcement in the region of the end of the beam. It is believed that this effect occurred because of the fact that the detailing followed from studies conducted in the UK is suitable for hinged connections while the connection analyzed in this research comprised of continuous negative reinforcing bars passing through the columns within the cast in place topping of the composite precast beam. Finally, this study presents further recommendations for improvements of the reinforcement detailing of the precast beam. / O estudo teve como objetivo principal analisar o comportamento estrutural de uma ligação viga-pilar com Consolo Metálico Embutido para estruturas pré-moldadas de concreto com uso ainda não corrente no Brasil. Após uma revisão bibliográfica sobre os principais consolos metálicos embutidos encontrados nas referências técnicas internacionais, escolheu-se um tipo de consolo metálico embutido que emprega um perfil metálico (chamado tarugo metálico). A revisão bibliográfica permitiu encontrar na literatura técnica e acadêmica vários modelos analíticos para o dimensionamento do perfil metálico, mas o estudo no presente trabalho se concentrou nos modelos revisados encontrados nos manuais do PCI (2010) e da FIB (2011). Além do estudo analítico, foram realizados ensaios exploratórios primeiramente em consolos no pilar isolado e em seguida foi ensaiado um modelo em escala real com duas vigas de seis metros e um pilar central. No primeiro modelo, denominado modelo de ensaio PI (Pilar Isolado), estudou-se o comportamento isolado do consolo e sua interação junto ao pilar. No segundo modelo, denominado modelo de ensaio LI (Ligação), estudou-se o comportamento da região da ligação e de interação com a viga. Para o estudo teórico-experimental, o tarugo metálico escolhido teve perfil retangular vazado de 200 mm x 100 mm x 10 mm de altura, largura e espessura respectivamente. No ensaio do modelo PI, o consolo metálico apresentou um comportamento rígido e foi capaz de suportar uma carga aplicada de 700 kN sem danos dentro do concreto do pilar. Já no caso do modelo LI, o estudo experimental analisou o comportamento conjunto da ligação, envolvendo tanto o consolo metálico quanto a extremidade da viga próximo ao consolo. Para este caso, a ligação se comportou como rígida para uma força cortante entre 239,5 kN e 238,3 kN, para a qual se estimou um momento de engastamento variando entre 1,0 e 0,96 para a ligação da esquerda e direita, respectivamente. Ocorreu ruptura por cisalhamento na capa de concreto na extremidade da viga quando a força cortante na seção atingiu 473,5 kN. A comparação dos resultados experimentais com os valores teóricos de cálculo demonstrou que o consolo isolado apresentou resistência compatível com o esperado, mas que a região da capa na extremidade da viga apresentou uma falha prematura devido à falta de armadura de costura na região da extremidade da viga. Acredita-se que este efeito tenha ocorrido em virtude do fato de que o detalhamento seguido a partir de estudos realizados no Reino Unido seja indicado para ligações articuladas, enquanto a ligação analisada consistiu de uma ligação com continuidade na armadura negativa. Por esta razão, este estudo apresenta recomendações para melhorias no detalhamento da viga.
92

Sistema pré-fabricado para aplicação em construções provisórias de canteiros de obras / Prefabricated temporary buildings for use in the construction site system

Knöner, Nery 23 May 2014 (has links)
Made available in DSpace on 2016-06-02T20:09:20Z (GMT). No. of bitstreams: 1 5987.pdf: 3490770 bytes, checksum: 4ec68db087fe4ce9be3c92acb03cd502 (MD5) Previous issue date: 2014-05-23 / Universidade Federal de Sao Carlos / The use of prefabricated elements has become increasing in Brazil, This paper describes the study and the procedures for construction and erection of a building system works on a pavement. Within the concept of technological innovation seeks to show a project in precast concrete that can be applied in facilities construction sites. Enables to meet the market demand for building construction sites in accordance with the requirements of the NR18 and ABNT (NB1367/NBR 12284, 1991), where all the actions of the production of construction happening and where the facilities are usually temporary and precarious. The system proposed solutions such as fast assembly, elimination of waste, and low cost, besides being a constructive process that can be reused in another bed, starting process without any loss of parts that compose it. Attaches itself to the system with one of the solutions that meets the needs of the construction industry in which it is possible to build construction sites, providing the employee satisfactory experiences in the area of enabling a modular installation adapting to the needs and administrative for the proper performance of the employee. / O emprego de elementos pré-fabricados tem se tornado crescente no Brasil, em virtude disso, o presente trabalho visa descrever o estudo e os procedimentos de construção e montagem de um sistema construtivo em obras de um pavimento. Partindo do que se entende como inovação tecnológica, a presente dissertação de mestrado, procura mostrar um projeto em pré-fabricados de concreto que poderá ser aplicado nas instalações de canteiros de obras. Este projeto possibilita que se atendam às demandas de mercado para construção de canteiros de obra de acordo com os quesitos da NR18 2012 e ABNT (NB1367/NBR 12284, 1991), onde todas as ações da produção da construção civil acontecem e onde as instalações normalmente são provisórias e precárias. O sistema pré-fabricado propõe soluções como: rapidez na montagem, eliminação de resíduos e baixo custo, além de utilizar um processo construtivo que pode ser reaproveitado em outro canteiro, iniciando-se todo processo sem perdas das peças que o compõe. Foi possível concluir que o sistema proposto pode representar uma importante solução que vem de encontro às necessidades do setor da construção civil, uma vez que os canteiros de obra podem proporcionar ao trabalhador condições satisfatórias na área de vivência, possibilitando instalação modular adequada às necessidades, refletindo em um bom desempenho por parte dos trabalhadores.
93

Avaliação de propriedades mecânicas de peças pré-moldadas submetidas à cura térmica pelo método da maturidade : estudo de caso /

Peres, Luciano Donizeti Pantano. January 2006 (has links)
Resumo: O Método da Maturidade é um ensaio não-destrutivo utilizado para avaliação das propriedades do concreto que estejam relacionadas ao desenvolvimento do grau de hidratação do material, a partir do seu histórico de temperaturas. O presente trabalho apresenta a aplicação dos conceitos do Método da Maturidade para analisar o desenvolvimento da resistência à compressão de elementos pré-moldados de concreto submetidos à cura térmica, a partir do monitoramento dos dados de tempo e temperatura junto à empresa Protendit, em São José do Rio Preto - SP, assim como a realização de ciclos térmicos no Laboratório CESP de Engenharia Civil (LCEC), em Ilha Solteira - SP, para elaboração da curva de calibração para utilização do método. A determinação da energia aparente de ativação, parâmetro necessário à aplicação do Método da Maturidade relacionado à velocidade da reação, foi realizada segundo o procedimento ASTM C 1074-98, permitindo verificar a influência das temperaturas de cura sobre os valores de energia de ativação determinados experimentalmente. Em conseqüência dos ciclos térmicos realizados na empresa, foi possível avaliar a distribuição de temperaturas nos elementos estruturais, com evidências do aparecimento de gradientes térmicos durante a realização da cura térmica, assim como a validação da aplicação do Método da Maturidade para estimar valores de resistência à compressão ao final do ciclo térmico. / Abstract: The Maturity Method is a non-destructive test used for evaluation of the concrete properties related with the development of concrete hydration degree, calculated from the time and temperature histories. This work presents the application of the Maturity Method concepts to analyze the development of the compression strength for precast concrete elements submitted to steam curing, starting from data of time and temperature acquired in a precast concrete factory, in São José do Rio Preto city - Brazil, as well as the execution of thermal cycles in the CESP Civil Engineering Laboratory (LCEC), in Ilha Solteira city - Brazil, for elaboration of the calibration curves used by Maturity Method. The determination of the apparent activation energy, necessary parameter for use of Maturity Method related to the reaction speed, it was executed according to the ASTM C 1074-98 procedure, allowing to verify the influence of curing temperatures on activation energy values. In consequence of the thermal cycles executed in precast concrete factory, it was possible to evaluate the temperature distribution in the structural elements, with evidences of thermal gradients appearance during steam curing, as well as the validation of Maturity Method application to esteem compression strength values at the end of thermal cycle. / Orientador: Mônica Pinto Barbosa / Coorientador: Roberto Caldas de Andrade Pinto / Banca: Cassio Roberto Macedo Maia / Banca: Marcelo de Araújo Ferreira / Mestre
94

Contribuição ao projeto de dentes de concreto para ligações em estruturas de concreto pré-moldado / Contribution to the design of dapped end beam for connections in precast concrete structures

Caio Cezar Catiste Silva 20 September 2017 (has links)
A presente pesquisa apresenta um estudo comparativo a respeito dos procedimentos para o projeto de dentes de concreto. O dente de concreto é um elemento estrutural bastante utilizado em ligações de estruturas de concreto pré-moldado. Atualmente existem vários procedimentos para o dimensionamento ou estimativa da capacidade resistente dessa ligação, entre os quais destacam-se o da ABNT (NBR 9062 e NBR 6118), PCI, ACI 318-14, Eurocode 2, entre outros. Neste contexto, a presente pesquisa objetiva à análise comparativa desses procedimentos de projeto com resultados experimentais disponíveis. Assim, esses procedimentos de projeto foram aplicados em 38 modelos experimentais de uma base de dados. Normalmente, as ruínas dos dentes de concreto são: a) escoamento da armadura do tirante; b) escoamento da armadura de suspensão; c) ruptura do concreto na região do dente. A relação entre a força de ruína experimental e a força de ruína calculada, designada por Fr,exp/Fr,cal, foi um dos parâmetros utilizados para avaliar as estimativas de força de ruína dos dentes de concreto. Na análise comparativa das estimativas para força de ruína por escoamento da armadura do tirante, a ABNT (NBR 9062 e NBR 6118) apresentou uma média de 1,26 e coeficiente de variação de 16,90%. A ACI 318-14 e o Eurocode 2 forneceram estimativas com uma média de 1,29 e coeficiente de variação de 17,6%. As estimativas do PCI tiveram uma média de 1,12 e coeficiente de variação de 17,9%. Para a ruína por escoamento da armadura de suspensão, as estimativas da ABNT (NBR 9062 e NBR 6118), PCI e ACI 318-14 (Modelos II e III) tiveram uma média de 1,22 e coeficiente de variação de 12,5%. O Eurocode 2 e a ACI 318-14 (Modelo I) apresentaram uma média de 1,87 para as estimativas e coeficiente de variação igual a 17,9%. Para a ruína por ruptura do concreto na região do dente, as estimativas da ACI 318-14 (Modelos II e III) apresetaram uma média de 1,56 e coeficiente de variação de 18,8%. Com o Modelo I, as estimativas da ACI 318-14 tiveram uma média de 1,60 e coeficiente de variação de 19,0%. O Eurocode 2 forneceu estimativas com uma média de 1,63 e coeficiente de variação de 14,6%. O PCI teve a pior estimativa com uma média de 3,29 e coeficiente de variação de 32,4%. O estudo ainda serviu como subsídio para o desenvolvimento de uma proposta para verificação da tensão de compressão no concreto. Para a região do dente, a proposta foi aplicada em 9 modelos experimentais da base de dados e apresentou uma média de 1,33 e um coeficiente de variação de 14,9%. / This research presents a comparative study about procedures for the design of dapped end beam. The dapped end beam is a structural element widely used in connections of precast concrete structures. Currently there are several procedures for the dimensioning or evaluation of the strength capacity of this connection, like as ABNT (NBR 9062 and NBR 6118), PCI, ACI 318-14 and Eurocode 2. In this context, the present research objetives to the comparative analysis of these design procedures with available experimental results. Thus, these design procedures were applied 38 experimental models of a database. Normally, the dapped end beam failures were: a) reinforcement yielding of the tie; b) yielding of the hanger bars; c) concrete rupture in the nib. The relation between the experimental failure force and calculated failure force, designated by Fr,exp/Fr,cal, was one of the parameters used to evaluate the estimates of failure force of dapped end beam. The ABNT (NBR 9062 e NBR 6118) presented an average of 1,26 and a coefficient of variation of 16,90% in the comparative analysis of the estimates for failure by the yielding of the tie. The ACI 318-14 and Eurocode 2 provided estimates with an average of 1,29 and coefficient of variation of 17,6%. The PCI estimates had an average of 1,12 and coefficient of variation of 17,9%. For failure by the yielding of hanger bars, estimates of ABNT (NBR 9062 and NBR 6118), PCI and ACI 318-14 (Models II and III) had an average of 1,22 and a coefficient of variation of 12,5%. Eurocode 2 and ACI 318-14 (Model I) presented an average of 1,87 for the estimates and coefficient of variation equal to 17,9%. For the rupture of concrete in nib, the ACI 318-14 (Models II and III) estimates presented an average of 1,56 and a coefficient of variation of 18,8%. With Model I, the estimates of ACI 318-14 had an average of 1,60 and a coefficient of variation of 19,0%. Eurocode 2 provided estimates with an average of 1,63 and a coefficient of variation of 14,6%. The PCI had the worst estimate with an average of 3,29 and coefficient of variation of 32,4%. The study also served as a subsidy for the development of a proposal for checking the concrete compressive stress. For nib, the simplified proposal was applied in 9 experimental models of the database and presented an average of 1,33 and a coefficient of variation of 14,9%.
95

Contribuição à análise da estabilidade global de estruturas em concreto pré-moldado de múltiplos pavimentos / Contribution in the analysis of global stability of multi-storey precast concrete framed structures

Marcelo Cuadrado Marin 04 December 2009 (has links)
No presente trabalho são avaliados os principais parâmetros de projeto na análise da estabilidade global de estruturas em concreto pré-moldado de múltiplos pavimentos, considerando a não-linearidade física (NLF), não-linearidade geométrica (NLG) e ligações semi-rígidas. Os sistemas estruturais analisados são constituídos por pórticos com ligação viga-pilar semi-rígida e pilares engastados na fundação. As ligações viga-pilar têm sua tipologia definida por chumbadores retos e capa de concreto moldado in loco com armadura de continuidade. A NLF é avaliada segundo a construção dos diagramas M x N x 1/r, onde foi considerado de forma consistente o efeito da força normal, da armadura passiva, da armadura ativa e a reologia do concreto. São propostas funções e definidos coeficientes redutores de rigidez que foram comparados com valores apontados em expressões normativas que contemplam de forma aproximada a NLF. A NLG é avaliada com o auxílio do programa ANSYS e na forma aproximada segundo o coeficiente z e o método da carga lateral fictícia (P-). Apresentam-se modelos analíticos de caracterização de rigidez e resistência de ligações viga-pilar ao momento fletor negativo e positivo. Na análise numérica é feito um estudo de caso completo de uma estrutura típica de múltiplos pavimentos em concreto pré-moldado com o auxílio do programa ANSYS, avaliando-se diferentes formas de consideração da NLF e da NLG. É analisada a distribuição de esforços na estrutura frente às combinações de ações utilizadas e os modelos de comportamento das ligações, para algumas variações de geometria e carregamento. Dentre as conclusões, pode ser citado que os coeficientes redutores obtidos segundo o diagrama M x N x 1/r divergem das indicações normativas para consideração simplificada de NLF. Quanto à consideração simplificada de análise NLG, o coeficiente z apresentou resultados melhores na previsão dos esforços de segunda ordem em relação aos obtidos por 0,95.z. / In this research it was evaluated the main design parameters in the analysis of global stability of multi-storey precast concrete framed structures considering the physical nonlinearity (PNL), geometric nonlinearity (GNL) and semi-rigid connections behavior. The structural systems considered are those consisting of frames with beam-to-column semi-rigid connection and columns inset in the foundation. The beam-to-column connections are defined by two dowels and cast-in-place concrete cap with longitudinal reinforced bars. The PNL is evaluated according the M x N x 1/r diagrams, where are considered the effect of normal force, the reinforcing steel, prestressing steel and creep. Functions are proposed and reducing stiffness coefficients are defined, with were compared with codes that include the approximated PNL. The GNL is evaluated according to ANSYS software by no approximate analisys and its approximate according to the coefficient z and (P-) method. This research presents an analytical model characterization of stiffness and strength of beam-to-column connections to the negative and positive bending moment. In the numerical analysis is made a full case study of a typical multi-storey precast concrete framed structure with the aid of the ANSYS software, evaluating different forms of consideration of the PNL and the GNL. It analysed the bending moment distribution according the combinations of actions used and the behavioral models of connections, for some variations at geometry and loading. The reduction coefficients of flexural rigidity obtained according the M x N x 1/r diagrams differ from normative indications for simplified account of PNL. In GNL simplified analysis, the coefficient z showed better results in predicting the second-order effects with respect to those obtained by the coefficient 0,95. z.
96

Contribuição ao projeto de vigas delgadas de seção \"L\" de concreto pré-moldado / Contribution to the design of precast concrete slender L-shaped beams

Marcus Vinícius Filiagi Pastore 05 August 2015 (has links)
Esta dissertação tem por objetivo contribuir para o projeto estrutural de vigas delgadas de seção \"L\" de concreto pré-moldado, também conhecidas no Brasil como vigas suporte-peitoril. O projeto deste tipo de viga apresenta uma maior complexidade que o de vigas usuais pela seção transversal assimétrica, carregamento excêntrico e as várias possibilidades de ligações viga-pilar e viga-laje. Em função de sua ligação com a laje, o comportamento deste tipo de viga pode apresentar diferentes modelos: a) com torção de equilíbrio; b) sem torção de equilíbrio; e c) com restrição parcial da rotação da laje. É mostrado que para relações altura da viga/largura da mesa inferior maiores que 2,5, a variação da orientação dos eixos principais de inércia com relação aos eixos vertical e horizontal pode ser desprezada. Além disso, o centro de cisalhamento pode ser considerado situado na linha de centro da alma para grandes relações altura da viga/altura da aba. Também são discutidas as ações e efeitos a serem considerados no projeto de vigas de seção \"L\". Em relação ao estado limite último, é mostrado que os procedimentos de dimensionamento de momento fletor e força cortante não diferem dos outros tipos de vigas de concreto, entretanto, o momento de torção pode ser tratado como flexão de placa por um método recomendado na última revisão do ACI-318. O comportamento da ligação alma/aba é considerado como dente de concreto e os seguintes aspectos de seu dimensionamento são apresentados: cálculo do tirante, cálculo da suspensão, cálculo da armadura longitudinal e verificação da biela crítica. Além disso, é levada em conta a resistência à punção da aba para efeito de forças concentradas. Também são discutidas as considerações para a flexão do peitoril que pode ocorrer pela ação lateral do vento e do impacto de veículos. Em relação ao estado limite de serviço, são apresentadas duas situações exclusivas para vigas de seção \"L\" com peitoril alto e delgado: formação de fissuras na extremidade e deformação lateral excessiva. Por fim, um exemplo de aplicação é desenvolvido para ilustrar particularidades no dimensionamento de vigas delgadas de seção \"L\" de concreto pré-moldado. / This thesis aims to contribute to the structural design of precast concrete slender L-shaped beams, also known as facade beams, spandrel beams, L-shaped edge beams and others. The design of these beams shows a greater complexity than usual concrete beams due to the asymmetric cross section, eccentric loads and the various possibilities for beam-column and beam-slab connections. According to their connection with the slab, the beam behavior can be divided into different models: a) with equilibrium torsion; b) without equilibrium torsion; c) with partial restriction of the slab rotation. It is shown that for height-to-total width ratios larger than 2.5, the variation of the orientation of the principal axes with respect to the vertical and horizontal axes can be neglected. Furthermore, the shear center can be considered located at the web center line for high values of the beam height-to-ledge height ratio. It is also discussed the actions and effects to be considered in the design of L-shaped beams. Regarding the ultimate limit state, it is shown that the bending moment and shear force procedures do not differ from other types of concrete beams, however, the torsion can be treated as plate bending by a recent method recommended in the latest ACI-318 revision. The ledge is considered as dapped end beams and the following aspects of its design are presented: transverse bending; hanger requirements; longitudinal bending and shear strength, including punching shear. It is also discussed the considerations for web flexure that may occur by wind action and lateral vehicle impact. Regarding the serviceability limit state, it is presented two unique situations for precast concrete slender L-shaped beams: crack formation at end regions and excessive lateral deflection. Lastly, an example is developed to illustrate particularities of the precast concrete slender L-shaped beam design.
97

Estudo experimental de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos e solda / Experimental study of a precast concrete beam-column connection using welded steel shapes

André Marcon Trotta 03 September 2012 (has links)
Nesta pesquisa estudou-se o comportamento de uma ligação viga-pilar em concreto pré-moldado utilizando perfis metálicos embutidos nos elementos estruturais. O modelo da ligação estudada permite a transmissão de momentos fletores positivo e negativo. Para a continuidade de momento fletor negativo, utilizam-se um consolo metálico com seção \"U\" embutido no pilar e dentes metálicos com seção tubular retangular embutidos nas vigas, soldados. Para a continuidade de momento positivo, utilizam-se cantoneiras metálicas embutidas no pilar que são soldadas à armadura positiva da viga. O estudo consistiu em análise experimental de um modelo cruciforme em duas etapas. Na primeira etapa o modelo foi solicitado a carregamentos cíclicos reversíveis por meio de um atuador servo hidráulico acoplado sobre o topo do pilar. Na segunda etapa, o modelo foi solicitado a carregamento estático monotônico por meio de macacos hidráulicos dispostos sob o pilar para causar a ruptura com momento negativo. O modelo apresentou uma considerável facilidade de montagem, já que na fase transitória a ligação é articulada e o consolo do pilar em perfil \"U\" permite a estabilidade lateral da viga. O consolo metálico embutido no pilar escoou muito antes de atingir a capacidade resistente dos outros componentes da ligação, pois na seção da ligação junto à face do pilar, apenas o consolo resiste à flexão. / In this research the behavior of a beam-column connection in precast concrete system using welded steel shapes built-in structural elements was studied. The model of the studied connection allows transmission of positive and negative moments. For the continuity of negative moment, is used a steel \"U\" shaped corbel inserted in the column welded with tubular section steel hangers inserted in each beam. For the continuity of positive moment, use is made of metal embedded in abutment ledges that are welded to the positive reinforcement of the beam. The study consisted on experimental analysis of a cross-shaped specimen in two steps. In the first step was applied to the specimen a cyclic load using hydraulic actuator coupled to the column head. In the second step was applied in the specimen a static load using hydraulic jack positioned under the column to cause rupture with negative moment. The connection model showed a considerably easy assembly, as in the transitional phase the connection is articulated and the steel \"U\" shaped corbel of the column allows the lateral stability of the beam. The rupture occurred by yielding of the steel U shaped corbel in the section near the column. The steel corbel inserted in the column yielded before reaches the resistant capacity of other components of the connection, because of the section in the connection close of the column, only steel corbel resists the negative moment.
98

Comportamento de chumbadores grauteados de ligações viga-pilar parcialmente resistentes a momento fletor / Behavior of grouted dowel of partial moment resistant beam-to-column connections

Eduardo Aurélio Barros Aguiar 05 May 2010 (has links)
Neste trabalho estudou-se o comportamento dos chumbadores grauteados, usados em ligações viga-pilar parcialmente resistentes a momento fletor. O foco da pesquisa foi a análise teórica e experimental do mecanismo resistente do chumbador inclinado. O programa experimental englobou 15 modelos, sendo que as variáveis analisados foram: a) diâmetros dos chumbadores, de 16 mm, 20 mm e 25 mm; b) inclinações dos chumbadores, de 0º (chumbador normal à interface), 45º e 60º; c) resistência à compressão do concreto adjacente ao chumbador, sendo usado concreto das classes C35 e C50; d) aplicação de força de compressão normal à interface. Os resultados experimentais indicaram aumentos significativos tanto na capacidade última quanto na rigidez a cisalhamento do chumbador. Foram realizadas simulações numéricas, onde foi verificada a sensibilidade dos resultados aos parâmetros inerentes à interface concreto - almofada de apoio, sendo desenvolvidas expressões para estimar tais parâmetros. Com base na análise experimental e em análises numéricas, foram propostos modelos analíticos que conseguiram representar de forma satisfatória a influência da inclinação e demais parâmetros analisados no mecanismo resistente do chumbador. / This research deals with the behavior of grouted dowels, used in partial moment resistant beam-to-column connections. The focus of the research was the theoretical and experimental analysis of dowels resistant mechanism. The experimental program include 15 models, and its variables analyzed were: a) the dowel diameter of 16 mm, 20 mm and 25 mm; b) the dowel inclination of 0° (dowels perpendicular to the interface), 45° and 60°; c) compressive strength of concrete adjacent to the dowels of classes C35 and C50, d) application of compression load, normal to the interface. Experimental results indicated significant increases in ultimate capacity and the shear stiffness of the dowels. Numerical simulations were carried out which identified the sensitivity of results to the parameters of the interface concrete bearing pad, and developed expressions to estimate such parameters are given. Based on experimental and numerical analysis analytical models have been proposed that could adequately represent the influence of inclination and other parameters in the mechanism resistant dowels.
99

Ligações de montagem viga-pilar para estruturas de concreto pré-moldado: estudo de caso / Assembly connections beam-column for structures of precast concrete: case study

Lisiane Pereira Prado 19 September 2014 (has links)
A pesquisa em questão é direcionada ao estudo de uma ligação provisória entre o pilar e a viga pré-moldada para que possa servir de suporte durante a execução da ligação de estrutura, que consiste na utilização de barras de aço salientes do pilar e da viga, traspassando entre si, finalizada por concreto com adição de fibras. O uso de consolo metálico formado por perfil tipo \"U\" e dente metálico constituído de um perfil de seção retangular vazado foi o método proposto para a ligação provisória, na qual a montagem da viga no pilar se dá pelo encaixe dos elementos. O modelo adotado como dente metálico é denominado \"Cazaly Hanger\". Para avaliar o comportamento da ligação estudada foram analisados os modelos analíticos referentes aos elementos da ligação e, posteriormente, foi montado um pórtico estrutural com a ligação provisória em estudo, para analisar o seu comportamento sob um carregamento estático e monotônico. Inicialmente foi aplicada uma força referente a 71,75% da capacidade da ligação, no meio do vão da viga e excêntrico ao seu eixo para analisar a torção na ligação, simulando uma possível força acidental que venha a ocorrer durante a montagem dos elementos. Na segunda etapa foi aplicada uma força a 1/2,94 do vão da viga a fim de determinar a capacidade do dente metálico e, na terceira e última etapa, o carregamento foi aplicado a 1/7,14 do vão da viga, na extremidade oposta a força aplicada na etapa 2, para determinar a capacidade de suporte do consolo metálico. Os resultados dos ensaios mostraram que a capacidade resistida pelo dente metálico foi 33% maior que o determinado no modelo analítico e, o estado limite último do consolo metálico constituído por perfil \"U\" foi caracterizado pela deformação excessiva da alma, na região superior do consolo. Pode-se concluir que o modelo de cálculo usado no trabalho foi coerente com os resultados encontrados para o dente metálico, mas, para os consolos metálicos, os valores teóricos não foram compatíveis com os resultados encontrados no modelo prático. / The research is directed to the study of a beam-column temporary connections to provide support during the execution of structure connection, which consist on using steel bars protruding from the column and beam finalized by addition of concrete with fibers. The use of steel \"U\" shaped corbel in the column and a steel hangers rectangular hollow core section in the beam was proposed for temporary connection method, in which the erecting the beam in the columns occurs by the nest of the elements. To evaluate the behavior of the studied connections it was analyzed the analytical models of connections and, after were building a structural portico with the connection to analyze their behavior under static and monotonic loading. Initially it was applied a load corresponding to 71,75% of the connection capacity, mid-span of the beam and its eccentric to check the torsion moment on the connection, simulating a possible live load that may occur during assembly of the elements. In the second stage was applied a load of 1/2,94 span beam to determine the capacity of steel hanger rectangular hollow core section and the third and last step the load was applied at 1/7,14 span of the beam, the end opposite the load applied in step 2, to determine the ability of the steel \"U\" shaped corbel. The results showed that the steel hanger inserted capacity was 33% higher than determined in the analytical model and the ultimate limit state of the steel \"U\" shaped corbel was characterized by excessive deformation of vertical plate, in the upper region of corbel. Can conclude that the calculation model used in the study was consistent with the results found for the steel hangers rectangular hollow core section, but for the steel \"U\" shaped corbel, the theoretical values were not consistent with the results found in practical model.
100

Instabilidade lateral de vigas pré-moldadas em situações transitórias / Lateral stability of precast concrete beams during transient situations

Pablo Augusto Krahl 30 April 2014 (has links)
O objetivo desta pesquisa é apresentar procedimentos de verificação da estabilidade lateral de vigas de concreto em situações transitórias e com eles realizar análises paramétricas. As fases transitórias estudadas são içamento, transporte e pré-serviço com e sem contraventamento nos apoios. As formulações apresentadas contém cálculo de carga crítica de instabilidade lateral, momento crítico e fator de segurança. São apresentados exemplos numéricos e a partir deles realizadas análises paramétricas com intuito de determinar limites de segurança. Os parâmetros variados foram fck, imperfeições geométricas, vão, largura da mesa comprimida e espessura da alma fazendo uma comparação entre vigas I e retangular. Com os resultados, foram obtidas esbeltezes geométricas limite para fases transitórias, relações entre carga crítica e carga devido ao peso próprio e uma relação entre momento crítico elástico e momento último de flexão para a fase transitória anterior à execução do tabuleiro com contraventamento nos apoios, especificamente. Na comparação entre vigas I e retangular, constatou-se que os dois tipos de seção apresentam limites de segurança distintos. As análises mostraram que os limites de esbeltez geométrica recomendados, como lh/bf², geram elementos, de seção transversal I, muito esbeltos. Este parâmetro apresentou uma variação significativa na tentativa de determinar limites nas análises paramétricas. Portanto, pode ser conservador adotar como limite a menor esbeltez obtida nas análises. Conclui-se que a verificação da segurança por esbeltezes geométricas nem sempre é adequada, pois não são considerados parâmetros como imperfeições geométricas e fck que mostraram serem importantes nas análises paramétricas. A esbeltez representada pela razão entre momento último e momento crítico de instabilidade elástico é mais abrangente e a busca por um valor limite deste parâmetro apresentou resultados com pouca variação para as vigas I. Com relação ao limite clássico de segurança que recomenda uma carga crítica maior que quatro vezes a carga de peso próprio, os resultados mostraram que esta recomendação é conservadora. As análises paramétricas mostraram que para vigas I esta razão igual a dois e meio atende a segurança destes elementos. / The objective of this research is to present a contribution to the verification of lateral stability of concrete beams in transient situations through parametric analyzes. The transient phases studied are lifting, transportation and prior to execution of the deck with braced and unbraced supports. Formulations presented contain calculation of buckling load, buckling moment and factor of safety. Numerical examples are presented and parametric analyzes are performed from these aiming to determine safety limits. The varied parameters were fck, geometric imperfections, span, compression flange width and web width by making a comparison between I-beams and rectangular beams. With the results, slenderness limits were obtained for transient phases, relationships between critical load and load due to self-weight and a relationship between elastic critical moment and ultimate moment to the transient situation before the execution of the deck with braced supports, specifically. In the comparison between I-beams and rectangular beams, it was found that the two types of section present different safety limits. Analyzes showed that the geometric slenderness limits recommended, as lh/bf², generate slender elements of I cross section. This parameter showed a significant variation in an attempt to determine limits on parametric analyzes. Therefore adopt the lower slenderness limit obtained in analyzes may be conservative. It is concluded that the safety verification by geometric slenderness is not always adequate, because they do not consider parameters such as geometric imperfections and fck that showed to be important in the parametric analyzes. The slenderness ratio represented by the ultimate moment and elastic critical moment of instability is more comprehensive and the search for a limiting value of this parameter presented results with little variation for the I-beams. With respect to the classical limit of safety which recommends that the critical load is greater than four times the self-weight load, the results showed that this recommendation is conservative. Parametric analyzes showed that for I-beams this ratio equal to two and a half addresses the safety of these elements.

Page generated in 0.0622 seconds