• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 3
  • 1
  • Tagged with
  • 12
  • 12
  • 9
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Apport des nouvelles technologies du sommeil en réanimation médicale, dans l’exploration de la maladie d’Alzheimer, du syndrome d’apnée du sommeil et en conditions extrêmes / Contribution of new technologies in sleep medicine in intensive care units, in Alzheimer exploration, in sleep apnea syndrome and in extremes conditions

El Baz, Maxime 14 January 2016 (has links)
Les technologies du sommeil connaissent une révolution numérique à laquelle nous avons apporté une validation avec pour objectif une meilleure analyse des troubles du sommeil en Unité de Soins Intensifs, dans la maladie d’Alzheimer et dans l’évaluation de l’hypovigilance en vol de longue durée en milieu militaire. Ainsi, nous avons évalué le temps de sommeil sur 24 heures en relation avec les nuisances sonores en soins intensifs. Cette évaluation a été réalisée à l’aide d’un nouveau polysomnographe l’Actiwave couplé à un polygraphe Nox T3 qui ont permis d’enregistrer les cycles du sommeil et les niveaux sonores sur les 24 heures dans une Unité de Soins Intensif. Nous avons montré que l’Actiwave est un outil performant pour enregistrer le sommeil dans de telles conditions. Combiné au Nox T3, il permet d’explorer l’impact des niveaux sonores sur la qualité et quantité du sommeil. Nous avons retrouvé un Temps Total de Sommeil médian de 6 heures par nuit et de 2,5 heures pendant la journée, la qualité de sommeil étant plus perturbée que sa quantité. Nous avons démontré que 60% des éveils intra-sommeil étaient associés à un bruit supérieur à 77 dB et identifié les sources sonores principales qui agissent sur la pathogénèse des troubles du sommeil en Unité de Soins Intensif, à savoir les alarmes des respirateurs mécaniques avec un risque relatif de 10.9 (9.8-11.9) et les alarmes des constantes vitales avec un risque relatif de 9.8 (8.6-11.3). Une deuxième étude, l’évaluation de l’hypovigilance en vol de longue durée, a été réalisée à l’aide de l’ActiWave. Pour cela, nos équipes ont conçu un algorithme d’analyse automatique de détection du sommeil. Nous avons montré que l’ActiWave est un polysomnographe fiable en conditions extrêmes, l’analyse automatique montrant une bonne concordance avec l’analyse manuelle de deux experts du sommeil (Kappa>80%). Nous démontrons donc qu’il est possible de coder automatiquement les stades de sommeil à l’aide du ratio (+)/ sur la région occipitale O1-M2 vs C3-M2 (p<0.05). Nous avons validé un nouvel actimètre le MotionWatch 8 pour l’évaluation du temps de sommeil chez 208 patients présentant la maladie d’Alzheimer. Ce travail a permis de montrer que le MotionWatch 8 est un outil fiable avec de bonnes sensibilité et spécificité dans l’évaluation des troubles du sommeil chez ces patients. Le Temps Total de Sommeil est dans la norme (TTS moyen 7h35 minutes) et est significativement associé au score d’apathie (7h46 minutes vs 7h26 minutes ; p=0.04). Le marqueur chrono-biologique SIJ est également associé à l’apathie (p=0.04) ainsi qu’aux troubles cognitifs (p=0.02). Finalement, la fragmentation de rythmes veille/sommeil (VIJ) est associée au score du handicap de la maladie d’Alzheimer (p=0.02). Dans une quatrième étude, nous nous sommes intéressés à la nouvelle technologie de télé-observance dans le traitement du syndrome d’apnées du sommeil par pression positive continue, qui permet d’alerter le médecin de la compliance du patient. Nous avons validé un nouveau dispositif médical de télé-observance du traitement du syndrome d’apnées du sommeil, le NOWAPI. Nous montrons que le NOWAPI mesure avec précision et de manière fiable les niveaux de pressions et de débits des PPC disponibles sur le marché et qu’il permet de calculer les indicateurs d'observance des patients souffrants du syndrome d’apnées du sommeil (IAH Nowapi de 2,5 (-1.4 ; 3.6)/h vs IAH Polygraphie respiratoire de 2,3 (1.2 ;3.4)/h). En conclusion, les études présentées ici mettent en exergue l’importance de l’innovation technologique dans le domaine du sommeil pour une meilleure prise en charge des patients. A l’ère du 21ème siècle, une nouvelle médecine commence à émerger, la médecine 2.0, avec pour corollaire l’eSanté. (...) / Scientific research into sleep over the past thirty years has progressed so speedily that it is now possible to speak of “Sleep Medicine”. This specialty is placed incontestably at the frontier of Science and Medicine. The issues have been recently driven by the advances in the technology of recording biological parameter and analysis of the data, in parallel with a deeper understanding of the physiopathology and therapeutic advances in sleep disorders. The subject of this thesis lies at the crossover of two areas of professional expertise; sleep technology and bio-engineering, with notably the aim of validating new tools in research as well as in the diagnosis and treatment of sleep disorders. We have tested a miniaturized polysomnographic new technology, the Actiwave, capable of detecting sleep and alert states in extreme conditions, notably in patients hospitalized in Intensive Care Units and in aircraft pilots in long duration military flights. In intensive care units, we have explored the relation between sleep and noise in the immediate environment of the patients. In brief, Total Sleep Time was not disturbed whereas the sleep quality was altered. Wake episodes after sleep onset were mostly associated with noise over 77 dB, and the main disturbances were triggered by the alarms of breathing machines and those from vital parameters. In military flights of long duration, we have explored the presence of hypovigilance episodes. This allowed us to validate the Actiwave for polysomnography in extreme conditions. In a third study, we have analyzed the sleep patterns in a total of 202 patients with Alzheimer’s disease by using a new actimeter, the MotionWatch8. We have shown that the latter device has a good sensitivity and specificity or evaluating sleep-wake parameters in these patients. In particular, we find that the TST is in the normal range and is associated with the aptathy score. The SIJ score is associated with the apathy score and also with the cognitive impairments. Finally, the sleep fragmentation is associated with the disability status. In a last study, we explored the parameter of sleep apneas in patients with SAS using the NOWAPI. We validated this new device by demonstrating that it provides on-line reliable data about pressure and flow levels of various CPAP. In conclusion, this thesis considers possible future avenues of research into sleep technology and discusses the crucial importance of a scientific approach capable of leading the development of appropriate and lasting diagnostic and therapeutic tools. The next step will be the era of the 2.0 medicine for which I am developing the iSommeil application that will allow patients to be the actual actors of their disease and also to facilitate the diagnostic and the prevention of sleep disorders.
12

Simulation numérique de la viscosité de liquides : effets des paramètres d'interaction, de la température et de la pression sous conditions ambiantes et extrêmes / Numerical simulation of the viscosity of liquids : effects of interaction parameters, temperature and pressure under ambient and extreme conditions

Meyer, Nadège 20 December 2017 (has links)
Ce travail est consacré à l'étude de la viscosité de cisaillement par simulation numérique de dynamique moléculaire classique à l'équilibre avec une attention particulière à l'influence des hautes pressions sur cette propriété. La viscosité est obtenue à partir des trajectoires générées par ces simulations et en appliquant la formule de Green-Kubo. Un large panel de systèmes a été étudié, allant de fluides atomiques purs à un liquide moléculaire, en passant par des mélanges binaires. En premier lieu, nous nous sommes focalisés sur les métaux alcalins. La conclusion majeure de cette étude est que la viscosité des alcalins a un comportement universel sur une large plage du diagramme de phases. Par ailleurs, sur cet intervalle, la relation universelle que nous avons proposée permet de prédire la valeur de la viscosité de n'importe quel élément avec une incertitude inférieure à 10%. La validité de la relation de Stokes-Einstein, reliant le coefficient d'autodiffusion à la viscosité, a également été vérifiée. Une étude systématique a ensuite été menée sur des mélanges modèles de type Lennard-Jones an de tester l'influence des paramètres d'interaction sur le comportement de la viscosité. Une estimation théorique basée sur le modèle de fluide effectif pur a été proposée. D'autre part, la relation de Stokes-Einstein a été étendue aux mélanges avec succès. Ces observations ont été confrontées aux cas de deux alliages réels : K-Cs et Li-Bi. Pour finir, une étude préliminaire a été entreprise sur l'eau en modélisant les interactions par deux potentiels : SPC/E, non polarisable, et BK3, polarisable. L'effet de l'introduction de la polarisabilité sur le calcul de la viscosité a été étudié. La validité des relations de Stokes-Einstein et de Stokes-Einstein-Debye, faisant intervenir la rotation de la molécule, a été évaluée à très haute pression / This work is devoted to the study of the shear viscosity by numerical simulation of equilibrium classical molecular dynamics with a particular attention to the influence of high pressures on this property. From trajectories generated by these simulations and using the Grenn-Kubo formula, the viscosity is obtained. A broad range of systems has been studied, covering from pure atomic fluids to a molecular liquid, as well as binary mixtures. First, we focused on alkali metals. The main outcome of this study is that the viscosity of these metals has a universal behavior over a wide range of phase diagram. Furthermore, over this interval, the universal relation that we have proposed permits the prediction of the viscosity value of any elements with an uncertainty lower than 10%. The validity of the Stokes-Einstein relation, connecting the self-diffusion coefficient and the viscosity, has also been verified. Then, a systematic study has been carried out on model mixtures of Lennard-Jones fluids to test the influence of interaction parameters on the viscosity behavior. A theoretical estimation based on the effective one-component fluid model has been proposed. Moreover, the Stokes-Einstein relation has been successfully extended to mixtures. These observations have been compared with two real alloys: K-Cs and Li-Bi. Lastly, a preliminary study on water has been undertaken by modeling the interactions with two models: SPC/E, non-polarizable and BK3, polarizable. The effect of the introduction of the polarizability on the viscosity has been studied. The validity of Stokes-Einstein and Stokes-Einstein-Debye, involving the rotation of the molecule, has been evaluated under very high pressure

Page generated in 0.1078 seconds