• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 25
  • 2
  • 2
  • Tagged with
  • 29
  • 29
  • 25
  • 25
  • 25
  • 23
  • 23
  • 23
  • 22
  • 21
  • 19
  • 6
  • 6
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Elaboração de um sistema de controle externo do fluxo eletrosmótico para eletroforese capilar com detecção condutométrica sem contato / Development of an external electroosmotic flow control system for capillary electrophoresis with contactless conductivity detection

Denis Tadeu Rajh Vidal 19 June 2008 (has links)
A presente dissertação trata da implementação, em um equipamento de eletroforese capilar (CE) com detecção condutométrica sem contato (C4D), de um sistema de controle externo do fluxo eletrosmótico (EOF) via tensão radial externa (Vrad). Através do potencial externo, aplicado diretamente ao capilar, é possível ter o controle do fluxo eletrosmótico de CE, pois, de forma simplificada, esta prática acopla vetorialmente um potencial externo aplicado com o potencial através da solução tampão dentro do capilar. O emprego da técnica possibilitou o aumento de resolução de 2 aminoácidos - Leucina e Isoleucina, cujas mobilidades diferem apenas de 0,12 cm2.V-1.s-1 entre si, em ácido acético 500 mmol.L-1 com pH = 2,55. A estratégia empregada aqui foi a que denominamos de \"coluna capilar infinita\", na qual, com as sucessivas inversões na direção do EOF, conseguimos aprisionar, dentro da coluna capilar, espécies com mobilidade eletroforética menor que a mobilidade do EOF. A literatura descreve que a inversão do EOF se torna mais difícil com o aumento do pH. Foram realizados testes em eletrólitos contendo agentes inversores de fluxo como o CTAB, o CaCl2 e o BaCl2. Ambos os aditivos foram usados em concentrações muito baixas, nas quais foi mantida a direção normal do EOF, sendo que a utilizaçãode tais agentes teve a finalidade apenas de reduzir os grupos silanolatos em soluções de pH acima de 6,0. Tal estratégia proporcionou a reversão do EOF no sistema tampão MES/HIS, cujo pH estava em torno de 6,1. Por fim, a pesquisa gerou uma perspectiva interessante que é a possibilidade de se encontrar combinações de eletrólitos de corrida e surfactantes com o intuito de se estender a faixa de alcance do Vrad para valores altos de pH. / This work presents the implementation, in an equipment for capillary electrophoresis (CE) with contactless conductivity detection (C4D), of a system for external control of the electroosmotic flow (EOF) via external radial voltage (Vrad). Through external potential, directly applied to the capillary, the electroosmotic flow can be controlled, because this practice couples the applied external potential to the zeta potential through the buffer solution within the capillary. The use of the technique allowed the baseline resolution of two amino acids (Leucine and Isoleucine), whose mobilities differ only by 0,12 cm2.V-1.s-1, using acetic acid 500 mmol.L-1 at pH = 2,55 as the running electrolyte. The approach, called \"infinite capillary column\", consists in successive reversals in the direction of the EOF, trapping species within the capillary column with electrophoretic mobility smaller than the EOF mobility. Thus, the two amino acids were retained by a period of approximately 120 minutes in the capillary that was enough to promote the baseline resolution. Previous works describe that the reversion of the EOF becoming more difficult as pH increases. In order to achieve a more effective control of EOF at high pH values (limiting the technique to a narrow performance band), tests were carried out in electrolytes containing flow reversing agents such as CTAB, CaCI2 and BaCI2. These additives were used at very low concentrations, which kept the normal direction of EOF, and the use of such agents had only the purpuse of reducing the density of silanolate groups in solutions of pH above 6,0. This approach allowed the reversion of the EOF using MES/HIS buffer, which pH was 6,1. Finally, this research has generated an interesting perspective about the possibility of finding combinations of electrolytes and surfactants aiming the Vrad range´s extension at high pH values.
22

Stanovení proteinogenních aminokyselin vysokoúčinnými separačními technikami / Determination of proteinogenic amino acids by high-performance separation techniques

Hodek, Ondřej January 2019 (has links)
(EN) Proteinogenic amino acids are key components of living organisms. Thus, the latest metabolomics research has focused on developing fast and sensitive methods for the determination of amino acids. In this context, this thesis contains two studies describing development of high-performance separation techniques for the quantification of amino acids. In the first study, a capillary electrophoresis method was developed for the determination of free amino acids in tobacco plants, particularly focusing on optimizing the extraction of amino acids from solid plant materials. The extraction procedure was optimized using design of experiments (DoE) to obtain the highest possible extraction yield of amino acids. Factors such as volume and concentration of the extraction solvent (hydrochloric acid) were assessed as the most significant. Subsequently, the optimal values of these factors were determined using response surface methodology (RSM). Lastly, proteinogenic amino acids were quantified using capillary electrophoresis with contactless conductivity detection and calibration with internal standard, which improved the precision of the method. The second study aimed at developing a supercritical fluid chromatography method for the determination of free proteinogenic amino acids in human plasma. The most...
23

Investigação por eletroforese capilar com detecção condutométrica sem contato sobre a formação e as propriedades de monoalquil carbonatos em meio aquoso / Investigation by capillary electrophoresis with contactless conductivity detection on the formation and properties of monoalkyl carbonates in aqueous medium

Vidal, Denis Tadeu Rajh 24 November 2011 (has links)
A formação dos monoalquil carbonatos (MACs) em meio aquoso - produzidos pela reação de um álcool e bicarbonato foi investigada por eletroforese capilar (CE) com detecção condutométrica sem contato (C4D). Foram estudadas ao todo 29 substâncias, das quais 25 apresentaram formação de adutos aniônicos monocarregados e 2 delas, adutos aniônicos com dupla carga. A eletroforese capilar proporcionou a obtenção de medidas de propriedades físico-químicas. Através do tempo de migração, foram obtidos mobilidade, coeficiente de difusão e raio iônico hidratado. Para os n-álcoois de 1 a 5 átomos de carbono, os adutos apresentaram raio iônico hidratado entre 216 pm e 310 pm. Os MACs têm raio iônico proporcional ao do álcool gerador, sendo sistematicamente maiores devidos à anexação do grupo carbonato. Quando comparado a ácidos carboxílicos de cadeia carbônica similar, os MACs possuem menor raio iônico hidratado. A obtenção dos valores da cinética de formação e hidrólise foi possível pela utilização de dupla detecção condutométrica, a qual permitia determinar a concentração do MAC em dois momentos diferentes ao longo da coluna. Devido à impossibilidade de uma calibração direta - já que os sais de MACs se decompõem em água - foi introduzida uma nova técnica de calibração que dispensa o uso de uma solução padrão do analito em favor de uma com espécie de mobilidade similar. As constantes cinética e termodinâmica foram comparadas com aquelas disponíveis na literatura, mostrando boa concordância, como no caso dos adutos para o metanol e etanol (a 25 ºC em meio aquoso), cujos valores da constante termodinâmica sugeridos pela literatura são de 3,57 e 1,80, respectivamente, enquanto que os valores calculados em nosso trabalho são de 4,2 e 2,3, a 25ºC. De forma similar ao ácido carbônico, os ácidos alquilcarbônicos (ACAs) se decompõem em meio ácido, o que dificulta a determinação da verdadeira constante de dissociação. Ainda assim, estudos em pH de 3 a 9, permitiram estimar os valores de pKa dos ácidos derivados de metanol, etanol e propanol como estando algo abaixo de 4, o que estaria em acordo com o valor de 3,6 do ácido carbônico. A formação de MACs também foi observada para dióis, como o etileno glicol e polióis, como o glicerol e manitol. Foi também possível observar, por eletroforese capilar, a formação de adutos aniônicos monovalentes para açúcares, tais como a sacarose, glicose e frutose. Por fim, a pesquisa revelou a possibilidade da formação de adutos com dupla carga - os bis(carbonatos) - para alguns dióis: o 1,4-butanodiol e o 1,6-hexanodiol. Esta é a primeira vez que estas espécies foram observadas. Estes resultados sugerem a formação de adutos aniônicos para várias outras classes de compostos, as quais possuam a hidroxila na cadeia carbônica. Embora, em meio predominantemente aquoso, estas espécies não estejam em alta concentração, trata-se de um novo conjunto de espécies a serem consideradas quando se trabalha em condições propícias. / The formation of monoalkyl carbonates (MACs) in aqueous medium - resulting from an alcohol and bicarbonate - was investigated by using capillary electrophoresis with capacitively coupled contactless conductivity detection (C4D). Twenty nine substances were studied. The mono-charged anionic adducts were observed for 25 of them and double-charged species were observed for 2. Capillary electrophoresis allowed us to obtain some physical-chemical properties. The migration time was used to calculate the ionic mobility, coefficient of diffusion, and hydrodynamic radius. The radii ranged from 216 to 310 pm for the adducts formed from the n-alcohols of 1 to 5 carbon atoms, respectively. The MACs have radii proportional to the size of the alcohol, being systematically greater because of the attached carbonate group. When compared to carboxylic acids of similar carbonic chain, the MACs have smaller radii. The calculation of the kinetic constants was possible due to the double C4D detection, which allows quantitation of the MAC at two different moments along the capillary. Due to the decomposition of the MAC salt in water, a direct quantitation was not possible. Thus an indirect calibration approach was introduced, where the analyte is substituted by a stable species of similar mobility. Good agreement was obtained between the kinetic and thermodynamic constants obtained by this method and those ones available in literature. For instance, the methanol and ethanol adducts were 4.2 and 2.3 (at 25 ºC), respectively, while the literature\'s values are 3.57 and 1.80. Similarly to carbonic acid, the alkyl carbonic acids (ACAs) decompose in acid medium, which impairs the determination of the dissociation constant. Even so, studies from pH between 3 and 9 allowed us to estimate that the pKa values of the adducts for methanol, ethanol, and propanol are somewhat below 4, which is in agreement with the value 3.6 for the carbonic acid. MACs were also observed for diols and polyols as well as for sugars. Finally, double-charged species bis(carbonates) were formed with 1,4-butanediol and 1,6-hexanediol. This is the first time that these species are reported. Although the concentrations of these species are not high in an aqueous medium, they form a new set of substance to be considered in aqueous solution when the conditions are favorable.
24

Fundamentos, produção e aplicações de marcas térmicas em eletroforese capilar / Fundamentals, production, and applications of thermal marks in capillary electrophoresis

Saito, Renata Mayumi 08 August 2011 (has links)
Em eletroforese capilar, a reprodutibilidade depende essencialmente da manutenção do sinal e no tempo de migração das espécies. A alteração do fluxo eletrosmótico (EOF) entre corridas é um dos principais fatores que afetam esses parâmetros. Nesse trabalho, é proposto um sistema de monitoramento do EOF baseado em marcas térmicas (TMs), que consistem em sinais presentes em um eletroferograma devido a uma perturbação do eletrólito de corrida ocasionada por um breve aquecimento (da ordem de 100 ms) de uma pequena porção do capilar (aproximadamente 1 mm), sob ação do campo elétrico. O dispositivo responsável pelo aquecimento que se mostrou mais eficiente consistiu em um resistor SMD de 15 Ω sobre o qual 5 V eram aplicados para gerar aquecimento. Estudos sobre a origem das TMs sugerem que o fenômeno está relacionado às mudanças do número de transporte das espécies devido à variação de temperatura. Essas conclusões foram baseadas na comparação do perfil dos sinais de TM com valores de número de transporte, além de estudos envolvendo simulação computacional. Diversas aplicações para as marcas térmicas foram propostas: correção de variação de tempo de migração devido a alterações do EOF, medida direta do EOF e para otimização de parâmetros do detector condutométrico sem contato. As TMs revelaram-se, então, um sistema prático e de fácil implementação, que pode ser utilizado como uma espécie de padrão interno. Adicionalmente, o emprego das TMs em um novo sistema de injeção de amostra, chamado de injeção térmica, foi também proposto. A vantagem desse tipo de injeção consiste na minimização de problemas de contínua introdução de amostra no canal de separação em microchip-CE. Para realizar essa injeção, o capilar é preenchido com a amostra diluída em um eletrólito de corrida e a injeção ocorre quando uma TM é gerada. Estudos com soluções de NaCl apresentaram faixa de resposta linear entre 10 µmol L-1 e 1 mmol L-1 para sódio. Entretanto, problemas de interferência sobre a sensibilidade e a mobilidade dos analitos foram obstáculos enfrentados. Também foi alvo de estudo o emprego da injeção térmica em uma técnica de multiplexação para aumento de relação sinal/ruído, baseado em um novo algoritmo. Embora o modelamento matemático tenha sido eficiente para decodificação de sinais, não foi possível obter o aumento na relação sinal/ruído almejado, pois o tempo de análise seria excessivamente longo. No entanto, a utilização da injeção térmica nesse tipo de estratégia mostrou-se bastante adequada, pois ela requer que diversas injeções sejam realizadas sequencialmente sem a interrupção do potencial de corrida, característica que esse sistema de injeção permite. Posteriormente, a implementação de estratégias que gerassem TMs em tempos mais curtos poderiam viabilizar a técnica. Finalmente, a utilização de TMs como ferramenta para obtenção de constantes físico-químicas, como pKa e mobilidade por exemplo, utilizando a eletroforese capilar mostra-se como uma grande perspectiva para a técnica / In capillary electrophoresis, reproducibility depends essentially on the maintenance of the signal and the migration time when the analysis of the same sample is repeated. Variations in the electroosmotic flow (EOF) between runs are one of the major factors affecting these parameters. In this work, a new approach to monitor the EOF based on thermal marks (TMs) is proposed. TM consists in a signal present in the electropherogram caused by heating (typically 100 ms) a small portion of the capillary (approximately 1 mm), while the electric field is applied. The most effective device to promote the heating was a 15-Ω SMD resistor, powered at 5 V. Studies about the origin of TMs suggest that the phenomenon is related to variations in the transport number of the species due to alterations in the temperature. This conclusion was based on comparison between the TM profile and the transport numbers values, as well as results from computer simulation. The proposed applications for TM include: correction in variations of migration times with alterations on EOF, EOF measurement and optimization of the parameters of contactless conductivity detection. Additionally, a new sample injection procedure, called thermal injection, was also proposed. The advantage of this injection consists in minimization of leakage problems related to the continuous introduction of the sample in the separation channel in microchip-CE. To perform the thermal injection, the capillary is completely filled with the sample diluted in a BGE and the injection occurs with the generation of a TM. Studies with NaCl solutions presented extensive linear response range from 10 µmol L-1 to 1 mmol L-1. However, interference problems on sensibility and analytes mobilities appeared. The use of low-concentration solutions diminishes these problems. However, the analytical signal is also diminished, needing a strategy to raise the sensitivity. Thus, a multiplexing technique based on a new algorithm was also introduced in order to improve signal-to-noise ratio. Although the efficiency of the mathematic modeling on the signals decoding, the desired improvement of signal/noise ratio was not obtained, because the analysis time would be excessively high. However, the employment of the thermal injection seems to be very suitable for multiplexing, due to the possibility of performing several sequential injections with no interruption of the electric field. Afterwards, the implementation of fast velocity devices to generate TMs would enable the technique. Finally, the great perspective to applications of TM concerns in the use of TMs to obtain physical chemical constants, such as pKa and ionic mobilities. The present work describes values of ionic mobilities calculated to monopropyl carbonate, monoisopropyl carbonate, and hydronium.
25

Desenvolvimento de métodos para coleta e determinação de poluentes em fase gasosa da atmosfera utilizando amostragem por difusão com membranas capilares microporosas / Development of methods for sampling and determination of gaseous pollutants in the atmosphere using diffusional microporous capillary membrane scrubber

Coelho, Lúcia Helena Gomes 23 November 2009 (has links)
A tese enfatiza o desenvolvimento e aplicação de amostradores difusionais para pré-concentração de traços de poluentes gasosos e sua conjugação com técnicas de separação e determinação, especialmente, a eletroforese capilar. Foram implementadas novas aplicações para um amostrador com múltiplos filamentos microporosos de polipropileno, previamente desenvolvido pelo grupo de pesquisa, e para o novo dispositivo de coleta de dimensões reduzidas, composto por monofilamento microporoso de polipropileno (CMDS) com volume interno de 30 µL. Para o estabelecimento da vazão estável em 1,0 µL min-1 de fase aceptora pelo capilar poroso, recorreu-se à pressurização do reservatório com uma bomba pneumática de aquário e regulagem de vazão por um capilar de sílica fundida e uma válvula de agulha. Outra bomba pneumática foi utilizada para aspirar o fluxo de ar amostrado. As amostras foram coletadas seqüencialmente em frascos de 200 µL, mantidos sob temperatura reduzida em unidade de refrigeração do tipo Peltier acoplado ao amostrador. O CMDS monofilamentar, mais compacto e robusto, apresentou alta eficiência de coleta para a pré-concentração de formaldeído (CH2O), ácidos fórmico e acético e amônia da fase gasosa da atmosfera. Para as espécies com elevada constante de Henry, água deionizada serviu como fase aceptora, enquanto que para amônia, recorreu-se ao deslocamento do equilíbrio por um aceptor ácido, de modo a reter o analito na forma de NH4 +. A concentração das espécies em fase líquida foi determinada posteriormente por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Os limites de detecção, em fase líquida, para formiato, acetato, formaldeído (determinado na forma do aduto hidroximetanosulfonato HMS) e amônio foram estimados em 1,0, 1,5, 1,2 e 1,2 µmol L-1, respectivamente (equivalentes à 0,9, 3,0, 1,0 e 0,7 µg m-3 dessas espécies na atmosfera, respectivamente). Para a determinação de CH2O por injeção em fluxo (FIA) acoplada à detecção amperométrica em eletrodo de ouro platinizado, fez-se uso do coletor multifilamentar, por atender melhor à necessidade de volume de amostra. A interferência de espécies comumente presentes na atmosfera, como H2O2 e SO2, pôde ser contornada realizando coletas em presença de peróxido de hidrogênio para promover a oxidação do S(IV) à S(VI) e, posteriormente, destruindo o oxidante em reator contendo enzima catalase imobilizada. A determinação de CH2O foi implementada com sucesso por FIA com detecção por amperometria em eletrodo de ouro platinizado. Um CMDS portátil que funciona à pilha, próprio para amostragens em campo, foi desenvolvido utilizando, para o deslocamento do ar amostrado, uma bomba de pistão retirada de aparelho automático para medida de pressão arterial. O amostrador foi empregado na coleta de H2S, SO2 e alquil-mercaptanas em fase gasosa da atmosfera, utilizando fase aceptora alcalina para promover a desprotonação e conseqüente fixação das espécies em meio líquido. Os analitos foram determinados por CE-C4D ou por microextração em fase sólida (SPME) seguida de determinação por GC. O uso conjunto do antioxidante ascorbato para conservação das amostras e de etanol para fixação dos compostos voláteis em meio aquoso permitiu o estabelecimento de um protocolo completo para coleta e detecção dessas espécies reduzidas de enxofre, com sensibilidade suficiente para monitorar emissões de origem biogênica, o que foi exemplificado na prática coletando amostras próximo a um córrego contaminado com esgoto. A perfeita combinação do diminuto volume de fase aceptora do CMDS com a demanda de nanolitros de amostra da CE-C4D culminou com o desenvolvimento de um sistema de análise total (TAS) com gerenciamento de fluidos baseado em propulsão por bombas de aquário (de baixo custo e alta durabilidade) e válvulas solenóide de estrangulamento, controladas por computador. Como exemplo de aplicação inovador e bem sucedido do TAS desenvolveu-se a análise concomitante e em tempo quase real de ácidos fórmico e acético no ar, com freqüência de 10 pares de dados por hora. As vantagens do sistema CMDS-CE-C4D incluem simplicidade, versatilidade, consumo de reagentes e amostra e geração de resíduos minimizada, robustez e rapidez enquanto uma amostra é coletada, o eletroferograma da anterior é adquirido sem necessidade de bombas de alta pressão ou colunas dispendiosas como as requeridas para HPLC / The development and application of porous membrane diffusion samplers for fast and efficient pre-concentration of an array of trace air pollutants was emphasized in this thesis, in conjunction with compatible separation and determination techniques, especially capillary electrophoresis. New applications were found for a formerly developed diffusion scrubber based on a bundle of microporous hollow polypropylene capillary membranes and for a scaled down version with a single core capillary membrane diffusion scrubber (CMDS) comprising an internal volume of 30 µL, were used for sampling of the trace level pollutants to an adequate liquid acceptor. The low-flow of acceptor solution, 1.0 µL min-1, required by the CMDS was satisfied by pressurization of the reservoir with an aquarium pump combined with flow regulation by a silica capillary as hydrodynamic resistor and a needle valve. Another aquarium pump was used for the aspiration of the sampled air through the sampler. The low volumes collected in the CMDS were stored in 200 µL vials inserted in a cooling plate of a Peltier device. The robust and compact system was used for sampling of formaldehyde (CH2O), formic acid, acetic acid and ammonia in the gaseous phase of the atmosphere. For chemical species with high Henry´s constant, deionized water suffices as acceptor phase. Otherwise, equilibria displacement to a non-volatile ion, like NH4 + for NH3 sampling, promoted quantitative retention in the acceptor phase. The concentrations of the analytes in the liquid phase were determined by capillary electrophoresis with capacitively coupled contactless conductometric detection (CEC4D). The detection limits obtained in the liquid phase for formate, acetate, formaldehyde (in the form of the adduct hydroxymethanesulfonate HMS) and ammonium were 1,0, 1,5, 1,2 e 1,2 µmol L-1 respectively (what corresponds to 0,9, 3,0, 1,0 e 0,7 µg m-3 of the respective gaseous species in the air). The higher volume of acceptor phase provided by the sampler with a bundle of microporous membrane capillaries (~600 µL) are in tune with the needs of flow injection analysis (FIA), as demonstrated for amperometric detection of CH2O on a platinized gold electrode. The interferences from SO2 and H2O2 were overcome by adding H2O2 to the acceptor solution to promote the oxidation of S(IV) to S(VI) and destruction of the oxidant afterwards in a column with immobilized catalase enzyme. The aquarium pump used for gas aspiration was substituted to a piston pump, taken from arterial blood pressure meter fed with 8 V D.C., to turn possible field collections with the CMDS device. The system was used for the sampling of H2S, SO2 e alkyl-mercaptans in the gaseous phase of the atmosphere. To succeed on that, the samplings were performed in alkaline media to promote deprotonation of the species (and stabilization in non-volatile forms). The collected analytes were determined by CE-C4D or by solid phase microextraction (SPME) followed by GC analysis. The joint use of the antioxidant ascorbate for sample preservation and ethanol for fixation of the volatile compounds allowed the establishment of a complete protocol for sampling, storage and detection of the sulfur reduced species with enough sensitivity for monitoring biogenic emissions from waste discharge. Perfect matching of the low-volume characteristics of the CMDS device and the CE-C4D equipment led to the conception of a low-cost automatic CMDS-CE-C4D total analysis system (TAS) and its innovative and successful application to near-realtime simultaneous analysis of formic acid and acetic acid in air. During the evaluation of one sample, the TAS collects a new one, with valves, pumps and high voltage delivery under software control. Advantages include rapidity (10 data points per hour for each analyte), high preconcentration efficiency, simplicity and versatility, minimum sample and reagent consumption and residue generation (green analytical method), no need of costly high pressure pumps and separation columns like those used in HPLC
26

Plataformas alternativas para sistemas eletroforéticos integrados com detecção condutométrica sem contato / Alternative platforms for electrophoretic systems integrated with contactless conductivity detection

Lobo Júnior, Eulício de Oliveira 10 March 2016 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2016-10-03T14:17:36Z No. of bitstreams: 2 Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2016-10-03T14:18:22Z (GMT) No. of bitstreams: 2 Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2016-10-03T14:18:22Z (GMT). No. of bitstreams: 2 Dissertação - Eunício de Oliveira Lobo Junior - 2016.pdf: 5628245 bytes, checksum: cb5cfdfdb21a0a9bed0292decf6c094f (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-03-10 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / This report describes the development of two alternative platforms for electrophoretic runs in microsystems. Firstly, the development of a hybrid capillary system that dispenses microfabrication steps is presented using fused silica capillaries interconnected by a commercial crossed shape interface. This hybrid system was coupled with contactless conductivity detector (C4D) to allow the determination of inorganic cations in biological samples. Electrokinetic sample injection was performed through gated mode approach for the first time in this arrangement. Operational parameters such as: (i) wave frequency and amplitude applied in C4D system, (ii) electrical potential applied in injection, (iii) injection time, (iv) detection point, (v) effect of capillary conditioning as well as and (vi) recovery percentage were extensively investigated and optimized. Better separations of cationic mixture containing NH4+, K+, Na+, Ca2+ and Mg2+ were achieved using a buffer system composed of 50 mM Lactic Acid, 20 mM Histidine and 3 mM 18-crown-6 on a capillary with effective length of 14.5 cm. . Addition of internal standard was used to ensure analytical reproducibility and allow the recording of merit figures. Linear behaviors were observed in concentration ranges between 10 and 100 M for NH4+, K+, Ca2+ e Mg2+, and 20-200 M for Na+. The limit of detection values calculated were 3.75 μM (NH4+), 3.70 μM (K+), 7.50 μM (Na+), 5.00 μM (Ca2+) and 5.35 μM (Mg2+). The concentration levels achieved for cations in biological samples ranged from 4,1 μM to 200 μM. Besides the hybrid system, this report also describes the development of an alternative methodology for the fabrication of high-relief masters for soft-lithography in poly(dimethylsiloxane) (PDMS) substrate. One of the innovative features makes reference to the use of low cost commercial photoresist from textile industry - poly(vinyl acetate) (PVAc) - which exhibits low toxicity. PVAc films were deposited on printed cirtuitry boards through the use of a homemade spincoater developed by desktop cooler, with rotation time control. This methodology allowed the production of high relief masters and PDMS channels with width and depth of 50 μm and 40 μm, respectively. Channels and masters profiles They were characterized with the following techniques: scan electron microscopy, perfilometry, optical and electrical. PDMS electrophoresis devices were successfully used for the separation of major inorganic cations. / Esta dissertação descreve o desenvolvimento de duas plataformas alternativas para a realização de eletroforese em microssistemas. Inicialmente é descrita um sistema eletroforético híbrido que dispensa etapas de microfabricação utilizando capilares de sílica fundida, conectados por uma interface comercial com formato em cruz. Este sistema capilar híbrido foi acoplado com detecção condutométrica sem contato (C4D) e aplicado na determinação de cátions inorgânicos (NH4+, K+, Na+, Ca2+, Mg2+) em amostras biológicas. A injeção de amostras foi realizada eletrocineticamente no modo gated, sendo o primeiro estudo em capilares utilizando esta modalidade de injeção. Foram avaliados os parâmetros operacionais de funcionamento do sistema incluindo (i) frequência e amplitude da onda senoidal aplicada ao sistema de detecção, (ii) potencial elétrico aplicado na injeção, (iii) tempo de injeção, (iv) composição do tampão, (v) ponto de detecção, (vi) efeito do condicionamento do capilar e (vii) recuperação. As melhores separações para uma mistura contendo os cátions inorgânicos foram obtidas usando-se um sistema tamponante composto de ácido lático 50 mM, histidina 20 mM e éter coroa (18-crown-6) 3 mM em um capilar com comprimento efetivo de 14,5 cm. As figuras de mérito analítico foram obtidas a partir da adição do íon Li+ como padrão interno, o qual assegurou confiabilidade nas análises quantitativas. A partir da otimização dos parâmetros analíticos, as curvas analíticas para os íons NH4+, K+, Ca2+ e Mg2+ exibiram comportamento linear (R2>0,99) na faixa de 10-100 M enquanto a curva analítica para o íon Na+ proporcionou resposta linear na faixa de 20-200 M. Os limites de detecção encontrados para os cinco cátions foram entre 3,75 μM (NH4+), 3,75 μM (K+), 7,50 μM (Na+), 5,00 μM (Ca2+) e 5,35 μM (Mg2+). O sistema desenvolvido foi explorado para a determinação dos cátions inorgânicos em amostras de urina, saliva e lágrimas. As concentrações encontradas nas amostras biológicas variaram de 4,1 μM a 200 μM. Além do sistema híbrido, a dissertação também apresenta uma metodologia de baixo custo para produção de moldes em alto relevo para litografia suave em poli(dimetilsiloxano) (PDMS). A principal inovação é o uso de fotoresiste de baixo custo, que se trata de uma emulsão fotossensível de poli(acetato de vinila) (PVAc) utilizada na indústria têxtil e que apresenta baixa toxicidade. Outra inovação é o controle da altura dos moldes utilizando um spincoater de produção própria, com controle de tempo de rotação. Com esta metodologia foram produzidos moldes em alto relevo, e microchips em PDMS com 50 μm de largura e 40 μm de altura. Foram realizadas separações eletroforéticas dos cátions NH4+,K+,Na+,Ca2+,Mg2+e Li+. As eficiências de separação variaram entre 73.000 e 120.000 pratos/m. O que comprova que a metodologia alternativa apresenta aplicabilidade microfluídica
27

Fundamentos, produção e aplicações de marcas térmicas em eletroforese capilar / Fundamentals, production, and applications of thermal marks in capillary electrophoresis

Renata Mayumi Saito 08 August 2011 (has links)
Em eletroforese capilar, a reprodutibilidade depende essencialmente da manutenção do sinal e no tempo de migração das espécies. A alteração do fluxo eletrosmótico (EOF) entre corridas é um dos principais fatores que afetam esses parâmetros. Nesse trabalho, é proposto um sistema de monitoramento do EOF baseado em marcas térmicas (TMs), que consistem em sinais presentes em um eletroferograma devido a uma perturbação do eletrólito de corrida ocasionada por um breve aquecimento (da ordem de 100 ms) de uma pequena porção do capilar (aproximadamente 1 mm), sob ação do campo elétrico. O dispositivo responsável pelo aquecimento que se mostrou mais eficiente consistiu em um resistor SMD de 15 Ω sobre o qual 5 V eram aplicados para gerar aquecimento. Estudos sobre a origem das TMs sugerem que o fenômeno está relacionado às mudanças do número de transporte das espécies devido à variação de temperatura. Essas conclusões foram baseadas na comparação do perfil dos sinais de TM com valores de número de transporte, além de estudos envolvendo simulação computacional. Diversas aplicações para as marcas térmicas foram propostas: correção de variação de tempo de migração devido a alterações do EOF, medida direta do EOF e para otimização de parâmetros do detector condutométrico sem contato. As TMs revelaram-se, então, um sistema prático e de fácil implementação, que pode ser utilizado como uma espécie de padrão interno. Adicionalmente, o emprego das TMs em um novo sistema de injeção de amostra, chamado de injeção térmica, foi também proposto. A vantagem desse tipo de injeção consiste na minimização de problemas de contínua introdução de amostra no canal de separação em microchip-CE. Para realizar essa injeção, o capilar é preenchido com a amostra diluída em um eletrólito de corrida e a injeção ocorre quando uma TM é gerada. Estudos com soluções de NaCl apresentaram faixa de resposta linear entre 10 µmol L-1 e 1 mmol L-1 para sódio. Entretanto, problemas de interferência sobre a sensibilidade e a mobilidade dos analitos foram obstáculos enfrentados. Também foi alvo de estudo o emprego da injeção térmica em uma técnica de multiplexação para aumento de relação sinal/ruído, baseado em um novo algoritmo. Embora o modelamento matemático tenha sido eficiente para decodificação de sinais, não foi possível obter o aumento na relação sinal/ruído almejado, pois o tempo de análise seria excessivamente longo. No entanto, a utilização da injeção térmica nesse tipo de estratégia mostrou-se bastante adequada, pois ela requer que diversas injeções sejam realizadas sequencialmente sem a interrupção do potencial de corrida, característica que esse sistema de injeção permite. Posteriormente, a implementação de estratégias que gerassem TMs em tempos mais curtos poderiam viabilizar a técnica. Finalmente, a utilização de TMs como ferramenta para obtenção de constantes físico-químicas, como pKa e mobilidade por exemplo, utilizando a eletroforese capilar mostra-se como uma grande perspectiva para a técnica / In capillary electrophoresis, reproducibility depends essentially on the maintenance of the signal and the migration time when the analysis of the same sample is repeated. Variations in the electroosmotic flow (EOF) between runs are one of the major factors affecting these parameters. In this work, a new approach to monitor the EOF based on thermal marks (TMs) is proposed. TM consists in a signal present in the electropherogram caused by heating (typically 100 ms) a small portion of the capillary (approximately 1 mm), while the electric field is applied. The most effective device to promote the heating was a 15-Ω SMD resistor, powered at 5 V. Studies about the origin of TMs suggest that the phenomenon is related to variations in the transport number of the species due to alterations in the temperature. This conclusion was based on comparison between the TM profile and the transport numbers values, as well as results from computer simulation. The proposed applications for TM include: correction in variations of migration times with alterations on EOF, EOF measurement and optimization of the parameters of contactless conductivity detection. Additionally, a new sample injection procedure, called thermal injection, was also proposed. The advantage of this injection consists in minimization of leakage problems related to the continuous introduction of the sample in the separation channel in microchip-CE. To perform the thermal injection, the capillary is completely filled with the sample diluted in a BGE and the injection occurs with the generation of a TM. Studies with NaCl solutions presented extensive linear response range from 10 µmol L-1 to 1 mmol L-1. However, interference problems on sensibility and analytes mobilities appeared. The use of low-concentration solutions diminishes these problems. However, the analytical signal is also diminished, needing a strategy to raise the sensitivity. Thus, a multiplexing technique based on a new algorithm was also introduced in order to improve signal-to-noise ratio. Although the efficiency of the mathematic modeling on the signals decoding, the desired improvement of signal/noise ratio was not obtained, because the analysis time would be excessively high. However, the employment of the thermal injection seems to be very suitable for multiplexing, due to the possibility of performing several sequential injections with no interruption of the electric field. Afterwards, the implementation of fast velocity devices to generate TMs would enable the technique. Finally, the great perspective to applications of TM concerns in the use of TMs to obtain physical chemical constants, such as pKa and ionic mobilities. The present work describes values of ionic mobilities calculated to monopropyl carbonate, monoisopropyl carbonate, and hydronium.
28

Investigação por eletroforese capilar com detecção condutométrica sem contato sobre a formação e as propriedades de monoalquil carbonatos em meio aquoso / Investigation by capillary electrophoresis with contactless conductivity detection on the formation and properties of monoalkyl carbonates in aqueous medium

Denis Tadeu Rajh Vidal 24 November 2011 (has links)
A formação dos monoalquil carbonatos (MACs) em meio aquoso - produzidos pela reação de um álcool e bicarbonato foi investigada por eletroforese capilar (CE) com detecção condutométrica sem contato (C4D). Foram estudadas ao todo 29 substâncias, das quais 25 apresentaram formação de adutos aniônicos monocarregados e 2 delas, adutos aniônicos com dupla carga. A eletroforese capilar proporcionou a obtenção de medidas de propriedades físico-químicas. Através do tempo de migração, foram obtidos mobilidade, coeficiente de difusão e raio iônico hidratado. Para os n-álcoois de 1 a 5 átomos de carbono, os adutos apresentaram raio iônico hidratado entre 216 pm e 310 pm. Os MACs têm raio iônico proporcional ao do álcool gerador, sendo sistematicamente maiores devidos à anexação do grupo carbonato. Quando comparado a ácidos carboxílicos de cadeia carbônica similar, os MACs possuem menor raio iônico hidratado. A obtenção dos valores da cinética de formação e hidrólise foi possível pela utilização de dupla detecção condutométrica, a qual permitia determinar a concentração do MAC em dois momentos diferentes ao longo da coluna. Devido à impossibilidade de uma calibração direta - já que os sais de MACs se decompõem em água - foi introduzida uma nova técnica de calibração que dispensa o uso de uma solução padrão do analito em favor de uma com espécie de mobilidade similar. As constantes cinética e termodinâmica foram comparadas com aquelas disponíveis na literatura, mostrando boa concordância, como no caso dos adutos para o metanol e etanol (a 25 ºC em meio aquoso), cujos valores da constante termodinâmica sugeridos pela literatura são de 3,57 e 1,80, respectivamente, enquanto que os valores calculados em nosso trabalho são de 4,2 e 2,3, a 25ºC. De forma similar ao ácido carbônico, os ácidos alquilcarbônicos (ACAs) se decompõem em meio ácido, o que dificulta a determinação da verdadeira constante de dissociação. Ainda assim, estudos em pH de 3 a 9, permitiram estimar os valores de pKa dos ácidos derivados de metanol, etanol e propanol como estando algo abaixo de 4, o que estaria em acordo com o valor de 3,6 do ácido carbônico. A formação de MACs também foi observada para dióis, como o etileno glicol e polióis, como o glicerol e manitol. Foi também possível observar, por eletroforese capilar, a formação de adutos aniônicos monovalentes para açúcares, tais como a sacarose, glicose e frutose. Por fim, a pesquisa revelou a possibilidade da formação de adutos com dupla carga - os bis(carbonatos) - para alguns dióis: o 1,4-butanodiol e o 1,6-hexanodiol. Esta é a primeira vez que estas espécies foram observadas. Estes resultados sugerem a formação de adutos aniônicos para várias outras classes de compostos, as quais possuam a hidroxila na cadeia carbônica. Embora, em meio predominantemente aquoso, estas espécies não estejam em alta concentração, trata-se de um novo conjunto de espécies a serem consideradas quando se trabalha em condições propícias. / The formation of monoalkyl carbonates (MACs) in aqueous medium - resulting from an alcohol and bicarbonate - was investigated by using capillary electrophoresis with capacitively coupled contactless conductivity detection (C4D). Twenty nine substances were studied. The mono-charged anionic adducts were observed for 25 of them and double-charged species were observed for 2. Capillary electrophoresis allowed us to obtain some physical-chemical properties. The migration time was used to calculate the ionic mobility, coefficient of diffusion, and hydrodynamic radius. The radii ranged from 216 to 310 pm for the adducts formed from the n-alcohols of 1 to 5 carbon atoms, respectively. The MACs have radii proportional to the size of the alcohol, being systematically greater because of the attached carbonate group. When compared to carboxylic acids of similar carbonic chain, the MACs have smaller radii. The calculation of the kinetic constants was possible due to the double C4D detection, which allows quantitation of the MAC at two different moments along the capillary. Due to the decomposition of the MAC salt in water, a direct quantitation was not possible. Thus an indirect calibration approach was introduced, where the analyte is substituted by a stable species of similar mobility. Good agreement was obtained between the kinetic and thermodynamic constants obtained by this method and those ones available in literature. For instance, the methanol and ethanol adducts were 4.2 and 2.3 (at 25 ºC), respectively, while the literature\'s values are 3.57 and 1.80. Similarly to carbonic acid, the alkyl carbonic acids (ACAs) decompose in acid medium, which impairs the determination of the dissociation constant. Even so, studies from pH between 3 and 9 allowed us to estimate that the pKa values of the adducts for methanol, ethanol, and propanol are somewhat below 4, which is in agreement with the value 3.6 for the carbonic acid. MACs were also observed for diols and polyols as well as for sugars. Finally, double-charged species bis(carbonates) were formed with 1,4-butanediol and 1,6-hexanediol. This is the first time that these species are reported. Although the concentrations of these species are not high in an aqueous medium, they form a new set of substance to be considered in aqueous solution when the conditions are favorable.
29

Desenvolvimento de métodos para coleta e determinação de poluentes em fase gasosa da atmosfera utilizando amostragem por difusão com membranas capilares microporosas / Development of methods for sampling and determination of gaseous pollutants in the atmosphere using diffusional microporous capillary membrane scrubber

Lúcia Helena Gomes Coelho 23 November 2009 (has links)
A tese enfatiza o desenvolvimento e aplicação de amostradores difusionais para pré-concentração de traços de poluentes gasosos e sua conjugação com técnicas de separação e determinação, especialmente, a eletroforese capilar. Foram implementadas novas aplicações para um amostrador com múltiplos filamentos microporosos de polipropileno, previamente desenvolvido pelo grupo de pesquisa, e para o novo dispositivo de coleta de dimensões reduzidas, composto por monofilamento microporoso de polipropileno (CMDS) com volume interno de 30 µL. Para o estabelecimento da vazão estável em 1,0 µL min-1 de fase aceptora pelo capilar poroso, recorreu-se à pressurização do reservatório com uma bomba pneumática de aquário e regulagem de vazão por um capilar de sílica fundida e uma válvula de agulha. Outra bomba pneumática foi utilizada para aspirar o fluxo de ar amostrado. As amostras foram coletadas seqüencialmente em frascos de 200 µL, mantidos sob temperatura reduzida em unidade de refrigeração do tipo Peltier acoplado ao amostrador. O CMDS monofilamentar, mais compacto e robusto, apresentou alta eficiência de coleta para a pré-concentração de formaldeído (CH2O), ácidos fórmico e acético e amônia da fase gasosa da atmosfera. Para as espécies com elevada constante de Henry, água deionizada serviu como fase aceptora, enquanto que para amônia, recorreu-se ao deslocamento do equilíbrio por um aceptor ácido, de modo a reter o analito na forma de NH4 +. A concentração das espécies em fase líquida foi determinada posteriormente por eletroforese capilar com detecção condutométrica sem contato (CE-C4D). Os limites de detecção, em fase líquida, para formiato, acetato, formaldeído (determinado na forma do aduto hidroximetanosulfonato HMS) e amônio foram estimados em 1,0, 1,5, 1,2 e 1,2 µmol L-1, respectivamente (equivalentes à 0,9, 3,0, 1,0 e 0,7 µg m-3 dessas espécies na atmosfera, respectivamente). Para a determinação de CH2O por injeção em fluxo (FIA) acoplada à detecção amperométrica em eletrodo de ouro platinizado, fez-se uso do coletor multifilamentar, por atender melhor à necessidade de volume de amostra. A interferência de espécies comumente presentes na atmosfera, como H2O2 e SO2, pôde ser contornada realizando coletas em presença de peróxido de hidrogênio para promover a oxidação do S(IV) à S(VI) e, posteriormente, destruindo o oxidante em reator contendo enzima catalase imobilizada. A determinação de CH2O foi implementada com sucesso por FIA com detecção por amperometria em eletrodo de ouro platinizado. Um CMDS portátil que funciona à pilha, próprio para amostragens em campo, foi desenvolvido utilizando, para o deslocamento do ar amostrado, uma bomba de pistão retirada de aparelho automático para medida de pressão arterial. O amostrador foi empregado na coleta de H2S, SO2 e alquil-mercaptanas em fase gasosa da atmosfera, utilizando fase aceptora alcalina para promover a desprotonação e conseqüente fixação das espécies em meio líquido. Os analitos foram determinados por CE-C4D ou por microextração em fase sólida (SPME) seguida de determinação por GC. O uso conjunto do antioxidante ascorbato para conservação das amostras e de etanol para fixação dos compostos voláteis em meio aquoso permitiu o estabelecimento de um protocolo completo para coleta e detecção dessas espécies reduzidas de enxofre, com sensibilidade suficiente para monitorar emissões de origem biogênica, o que foi exemplificado na prática coletando amostras próximo a um córrego contaminado com esgoto. A perfeita combinação do diminuto volume de fase aceptora do CMDS com a demanda de nanolitros de amostra da CE-C4D culminou com o desenvolvimento de um sistema de análise total (TAS) com gerenciamento de fluidos baseado em propulsão por bombas de aquário (de baixo custo e alta durabilidade) e válvulas solenóide de estrangulamento, controladas por computador. Como exemplo de aplicação inovador e bem sucedido do TAS desenvolveu-se a análise concomitante e em tempo quase real de ácidos fórmico e acético no ar, com freqüência de 10 pares de dados por hora. As vantagens do sistema CMDS-CE-C4D incluem simplicidade, versatilidade, consumo de reagentes e amostra e geração de resíduos minimizada, robustez e rapidez enquanto uma amostra é coletada, o eletroferograma da anterior é adquirido sem necessidade de bombas de alta pressão ou colunas dispendiosas como as requeridas para HPLC / The development and application of porous membrane diffusion samplers for fast and efficient pre-concentration of an array of trace air pollutants was emphasized in this thesis, in conjunction with compatible separation and determination techniques, especially capillary electrophoresis. New applications were found for a formerly developed diffusion scrubber based on a bundle of microporous hollow polypropylene capillary membranes and for a scaled down version with a single core capillary membrane diffusion scrubber (CMDS) comprising an internal volume of 30 µL, were used for sampling of the trace level pollutants to an adequate liquid acceptor. The low-flow of acceptor solution, 1.0 µL min-1, required by the CMDS was satisfied by pressurization of the reservoir with an aquarium pump combined with flow regulation by a silica capillary as hydrodynamic resistor and a needle valve. Another aquarium pump was used for the aspiration of the sampled air through the sampler. The low volumes collected in the CMDS were stored in 200 µL vials inserted in a cooling plate of a Peltier device. The robust and compact system was used for sampling of formaldehyde (CH2O), formic acid, acetic acid and ammonia in the gaseous phase of the atmosphere. For chemical species with high Henry´s constant, deionized water suffices as acceptor phase. Otherwise, equilibria displacement to a non-volatile ion, like NH4 + for NH3 sampling, promoted quantitative retention in the acceptor phase. The concentrations of the analytes in the liquid phase were determined by capillary electrophoresis with capacitively coupled contactless conductometric detection (CEC4D). The detection limits obtained in the liquid phase for formate, acetate, formaldehyde (in the form of the adduct hydroxymethanesulfonate HMS) and ammonium were 1,0, 1,5, 1,2 e 1,2 µmol L-1 respectively (what corresponds to 0,9, 3,0, 1,0 e 0,7 µg m-3 of the respective gaseous species in the air). The higher volume of acceptor phase provided by the sampler with a bundle of microporous membrane capillaries (~600 µL) are in tune with the needs of flow injection analysis (FIA), as demonstrated for amperometric detection of CH2O on a platinized gold electrode. The interferences from SO2 and H2O2 were overcome by adding H2O2 to the acceptor solution to promote the oxidation of S(IV) to S(VI) and destruction of the oxidant afterwards in a column with immobilized catalase enzyme. The aquarium pump used for gas aspiration was substituted to a piston pump, taken from arterial blood pressure meter fed with 8 V D.C., to turn possible field collections with the CMDS device. The system was used for the sampling of H2S, SO2 e alkyl-mercaptans in the gaseous phase of the atmosphere. To succeed on that, the samplings were performed in alkaline media to promote deprotonation of the species (and stabilization in non-volatile forms). The collected analytes were determined by CE-C4D or by solid phase microextraction (SPME) followed by GC analysis. The joint use of the antioxidant ascorbate for sample preservation and ethanol for fixation of the volatile compounds allowed the establishment of a complete protocol for sampling, storage and detection of the sulfur reduced species with enough sensitivity for monitoring biogenic emissions from waste discharge. Perfect matching of the low-volume characteristics of the CMDS device and the CE-C4D equipment led to the conception of a low-cost automatic CMDS-CE-C4D total analysis system (TAS) and its innovative and successful application to near-realtime simultaneous analysis of formic acid and acetic acid in air. During the evaluation of one sample, the TAS collects a new one, with valves, pumps and high voltage delivery under software control. Advantages include rapidity (10 data points per hour for each analyte), high preconcentration efficiency, simplicity and versatility, minimum sample and reagent consumption and residue generation (green analytical method), no need of costly high pressure pumps and separation columns like those used in HPLC

Page generated in 0.1171 seconds