• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 325
  • 66
  • 14
  • 14
  • 12
  • 5
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 490
  • 490
  • 433
  • 390
  • 314
  • 310
  • 280
  • 279
  • 64
  • 63
  • 62
  • 57
  • 54
  • 53
  • 52
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Diseño y puesta a punto de un método cefalométrico en 3D para el estudio de la población ortodóncica

Zamora Martínez, Natalia 07 July 2011 (has links)
Introducción: La introducción de la tomografía computarizada de haz cónico (CBCT) y su aplicación clínica a la imagen craneofacial tridimensional (3D) supone una herramienta diagnóstica esencial para el clínico. Objetivos: 1-Evaluar la reproducibilidad en la localización de puntos cefalométricos pertenecientes a tejidos duros del cráneo sobre imágenes escaneadas con un equipo CBCT 2-Comprobar si los valores de diferentes mediciones de las reconstrucciones 3D del CBCT se pueden comparar a las mediciones realizadas sobre imágenes 2D de la telerradiografía lateral de cráneo y comparar también si existen diferencias entre dos tipos diferentes de software de CBCT. 3-Diseñar un método cefalométrico 3D y determinar tres planos de referencia en cada uno de los ejes del espacio. Aplicar dicho análisis sobre una muestra de pacientes a los que se les ha realizado un CBCT. Material y Método: Se recogió una muestra global de 90 pacientes que tenían realizado un CBCT i-Cat®. 1-Para hallar la reproducibilidad, 15 CBCTs fueron seleccionados. Dos observadores localizaron 41 puntos en 3 ocasiones con el software NemoCeph 3D®. Se calcularon los Coeficientes de Correlación Intraclase (ICC) intra e interexaminador y se hallaron los errores de localización y asociados al método de medida de cada uno de los puntos. 2-Se seleccionaron 8 casos que tenían realizado además del CBCT, una telerradiografía lateral de cráneo convencional. Las telerradiografías se tomaron con el cefalostato Orthophos Plus DS® y se evaluaron con el software Dental Studio NX®, mientras que las reconstrucciones 3D (CBCT) se evaluaron con dos software diferentes, NemoCeph 3D® e InVivo5®. Un observador midió en dos ocasiones 10 medidas angulares y 3 lineales en cada uno de los registros, hallándose las correlaciones entre los tres tipos de métodos. 3-Se diseñó una cefalometría 3D y se empleó la muestra de los 90 CBCT para hallar los valores cefalométricos descriptivos de cada una de las variables creadas en cada una de las áreas de estudio: patrón facial, clase esquelética, relación maxilo-mandibular, medidas transversales, asimetrías, proporción facial y análisis dentoalveolar; mediante el cálculo de medias y desviaciones típicas, así como correlaciones de las diferentes variables entre sí y en función de la edad y del sexo. Resultados: 1-La reproducibilidad en la localización de los puntos cefalométricos para todos los ejes fue elevada (ICC ≥0.9) en las medidas intraobservador e interobservador. Analizando cada uno de los puntos por separado se encontró que el valor promedio de su desviación típica en todos los ejes fue igual a 1.0 mm. 2-No se encontraron diferencias estadísticamente significativas para ninguna de las medidas entre la telerradiografía lateral de cráneo y los CBCT, siendo los niveles de significación para todas las mediciones ICC>0.65. 3-Se ha creado un plano vertical de referencia (Na, S, Ba) así como diversos planos auxiliares y medidas lineales. Se han establecido las medias y desviaciones típicas de cada una de las variables del análisis 3D estudiadas, estableciendo así mismo diferentes correlaciones que nos sirven para la posterior creación de una base de datos. Conclusiones: 1-Se encontró elevada reproducibilidad en la localización de todos los puntos cefalométricos. Los puntos nasion, silla, basion, suturas frontocigomáticas, puntos anteriores de la rama, primer molar superior izquierdo e incisivo superior se pueden considerar como puntos altamente reproducibles para poder ser empleados en los análisis cefalométricos tridimensionales. 2-Es posible emplear la mayor parte de los valores establecidos en 2D para las mediciones 3D. Así mismo, las mediciones 3D no difieren entre NemoCeph 3D e InVivo5®, pudiéndose realizar las mediciones indistintamente en cualquiera de los dos software. 3-Se ha diseñado un método cefalométrico tridimensional dividido por áreas de interés que puede servir como punto de partida para la evaluación y medición de las características craneofaciales de todos aquellos pacientes que precisen como registro diagnóstico un CBCT. / Introduction: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The aims were 1-To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2-To assess whether the values of different measurements taken on 3D reconstructions from CBCT are comparable with those taken on 2D images from conventional lateral cephalometric radiographs (LCR) 3-To introduce planes of reference and create a cephalometric analysis appropriated to the 3D reality. Study design: 90 patients who had a CBCT (i-Cat®) as a diagnostic register were selected. 1-To assess the reproducibility 15 CBCT were analysed. 41 landmarks were defined on the three spatial axes (X,Y,Z) and located by two observers at different times with the NemoCeph 3D® software. 2-To compare 13 measurements between LCR (Orthophos Plus DS®) and CBCT, 8 patients who had both registers were selected. Measurements were done with softwares Dental Studio NX® (LCR), NemoCeph 3D® (CBCT) e InVivo5® (CBCT). 3-To create and evaluate three spatial planes and a 3D analysis divided in different areas of interest, the 90 CBCT were selected. Results: 1- Intra- and inter-examiner reliability was high, both being ICC ≥ 0.99, with the best frequency on axis Z. 2- No statistically significant differences were found for the angular and linear measurements between the LCR and the CBCTs for any measurement being the correlation levels ICC<0.65. 3- Mean values, standard deviations and correlations of each one of the measurements defined on the 3D analysis were evaluated for all patients. Conclusions: 1-High reliability was found for all the landmarks. The most reliable ones were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. 2-No statistically significant differences were found between measurements taken on the LCR and CBCT and in those taken between the two CBCTs. 3-A new 3D analysis has been created and can be applied to measure and evaluate those patients who require a CBCT as a diagnostic register.
372

Tomographie par rayons X : correction des artefacts liés à la chaîne d'acquisition

Wils, Patricia 17 November 2011 (has links) (PDF)
L'imagerie cone-beam computed tomography (CBCT) est une méthodologie de contrôle non destructif permettant l'obtention d'images volumiques d'un objet. Le système d'acquisition se compose d'un tube à rayons X et d'un détecteur plan numérique. La recherche développée dans ce manuscrit se déroule dans le contexte industriel. L'objet est placé sur une platine de rotation et une séquence d'images 2D est acquise. Un algorithme de reconstruction procure des données volumiques de l'atténuation de l'objet. Ces informations permettent de réaliser une étude métrologique et de valider ou non la conformité de la pièce imagée. La qualité de l'image 3D est dégradée par différents artefacts inhérents à la plateforme d'acquisition. L'objectif de cette thèse est de mettre au point une méthode de correction adaptée à une plateforme de micro-tomographie par rayons X d'objets manufacturés poly-matériaux. Le premier chapitre décrit les bases de la physique et de l'algorithmie propres à la technique d'imagerie CBCT par rayons X ainsi que les différents artefacts nuisant à la qualité de l'image finale. Le travail présenté ici se concentre sur deux types d'artefacts en particulier: les rayonnements secondaires issus de l'objet et du détecteur et le durcissement de faisceau. Le second chapitre présente un état de l'art des méthodes visant à corriger le rayonnement secondaire. Afin de quantifier le rayonnement secondaire, un outil de simulation basé sur des techniques de Monte Carlo hybride est développé. Il permet de caractériser le système d'acquisition installé au laboratoire de façon réaliste. Le troisième chapitre détaille la mise en place et la validation de cet outil. Les calculs Monte Carlo étant particulièrement prohibitifs en terme de temps de calcul, des techniques d'optimisation et d'accélération sont décrites. Le comportement du détecteur est étudié avec attention et il s'avère qu'une représentation 2D suffit pour modéliser le rayonnement secondaire. Le modèle de simulation permet une reproduction fidèle des projections acquises avec le système réel. Enfin, le dernier chapitre présente la méthodologie de correction que nous proposons. Une première reconstruction bruitée de l'objet imagé est segmentée afin d'obtenir un modèle voxélisé en densités et en matériaux. L'environnement de simulation fournit alors les projections associées à ce volume. Le volume est corrigé de façon itérative. Des résultats de correction d'images tomographiques expérimentales sont présentés dans le cas d'un objet mono-matériaux et d'un objet poly-matériaux. Notre routine de correction réduit les artefacts de cupping et améliore la description du volume reconstruit.
373

The production and detection of optimized low-Z linear accelerator target beams for image guidance in radiotherapy

Parsons, David, Parsons, David 22 August 2012 (has links)
Recent work has demonstrated improvement of image quality with low atomic number (Z) linear accelerator (linac) targets and energies as low as 3.5 MV compared to a standard 6 MV therapeutic beam. In this work, the incident electron beam energy has been lowered to energies between 1.90 and 2.35 MeV. The improvement of megavoltage planar image quality with the use of carbon and aluminum linac targets has been assessed compared to a standard 6 MV therapeutic beam. Common electronic portal imaging devices contain a 1.0 mm copper conversion plate to increase detection efficiency of a therapeutic megavoltage spectrum. When used in imaging with a photon beam generated with a low-Z target, the conversion plate attenuates a substantial proportion of photons in the diagnostic range, thereby reducing the achievable image quality. Image quality as a function of copper plate thickness has been assessed for planar imaging and cone beam computed tomography.
374

The validity, reliability and time requirement of study model analysis using cone-beam computed tomography generated virtual study models

Luu, Nghe S. Unknown Date
No description available.
375

Evaluation of dose and image quality parameters for cone-beam CT localization protocols in radiation therapy

Jacome, Victor Roland. January 2009 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves 152-154.
376

Estudo da identificação humana por meio da imaginologia dos seios frontais.

Almeida, Manuella Santos Carneiro 13 March 2012 (has links)
Made available in DSpace on 2015-05-14T12:56:00Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 2176646 bytes, checksum: 1bc824e5cb69d2fcdee753f80f5eb8df (MD5) Previous issue date: 2012-03-13 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to verify the applicability of parameters for human identification using the frontal sinuses, used by Tatlisumak et al. (2007), using axial and coronal reconstructions of CBCT and extraoral radiographs. From 58 dry disjointed skulls existing in the Management of Legal Medicine of Paraiba (PB-GEMOL) and University Center of Joao Pessoa, UNIPÊ, 26 skulls were selected. The acquisition of anteroposterior radiographs of the skull and lateral view were obtained through X-ray machine pan Rotograph Plus ® (Dabi Atlante Ltda., Ribeirão Preto, São Paulo, Brazil) and the CT at New iCAT device Generation ® (Imaging Sciences International, Pennsylvania, USA), adopting a specific methodology in order to standardize the tests to obtain and ensure the reproducibility of the study. The images were evaluated by two examiners calibrated in darkened environment and in two different times, with a minimum interval of one week. Assessments of axial and coronal reconstructions were performed with the aid of a 23 "program and iCat Vision (Imaging Sciences International, Pennsylvania, USA). For evaluation of extraoral radiographs were traced on paper made using ultrafan of 600 lux light box with mask and measurements with the aid of a high precision digital caliper Mitutoyo series 167 (Mitutoyo, Suzano, Brazil). Categorical variables were discrete and analyzed using the kappa test and continuous variables by Correlation Coefficient of Concordance Lin. Methods of analysis by cone beam CT and radiographic were mostly consistent, with only a few variables with unsatisfactory results (capd, and dpele dpontalt). For categorical variables and discrete intra-and inter-was great-perfect for both methods, as continuous variables showed moderate to excellent results. It is concluded that: the methodology proposed in this paper, using the parameters of the job Tatlisumak et al. (2007), are applicable and reliable in extraoral radiographs (X-rays AP and lateral radiographs of the skull face) and axial and coronal reconstructions of CBCT for human identification by frontal sinus, intra-and inter the parameters used by Tatlisumak et al. (2007) with CBCT imaging modality varies from substantial to excellent, and moderate to excellent radiographic images, there is a greater power of reproducibility and accuracy of the proposed method using the axial and coronal reconstructions of CBCT taking extraoral radiographs also reliability , the least consistent variable in the analysis by the images of CBCT is a measure capd (poor agreement), while the radiographic images and are dpele dpontalt (bad matches). This result indicates that these parameters are more susceptible to errors by evaluators, since it needs to use multiple points of reference for their measurements. / O objetivo neste estudo foi verificar a aplicabilidade de parâmetros de identificação humana por meio dos seios frontais, utilizados por Tatlisumak et al. (2007), com auxílio das reconstruções axiais e coronais de tomografia computadorizada de feixe cônico (TCFC) e radiografias extrabucais. De um universo de 58 crânios secos desarticulados existentes na Gerência Executiva de Medicina e Odontologia Legal da Paraíba (GEMOL-PB) e Centro Universitário de João Pessoa, Unipê, foram selecionados 26 crânios. As aquisições das imagens radiográficas póstero-anterior de crânio e lateral de face, foram obtidas por meio do aparelho de raios X panorâmico Rotograph Plus® (Dabi Atlante Ltda., Riberão Preto, São Paulo, Brasil) e as tomográficas, pelo aparelho iCAT New Generation® (Imaging Sciences International, Pennsylvania, EUA), adotando-se uma metodologia específica como forma de padronizar a obtenção dos exames e garantir a reprodutibilidade do estudo. As imagens foram avaliadas por dois examinadores previamente calibrados, em ambiente escurecido e em dois tempos distintos, com um intervalo mínimo de uma semana. As avaliações das reconstruções axiais e coronais foram realizadas com o auxílio de um monitor de 23 e programa iCat Vision (Imaging Sciences International, Pennsylvania, EUA). Para avaliação das imagens radiográficas extrabucais, foram realizados traçados em papel ultrafan utilizando negatoscópio de 600 lux com máscara e as mensurações com auxílio de um paquímetro digital de alta precisão Mitutoyo série 167 (Mitutoyo Sul Americana, Suzano, Brasil). As variáveis categóricas e discretas foram analisadas por meio do teste kappa e as variáveis contínuas pelo Coeficiente de Correlação de Concordância de Lin. Os métodos de análise pelas tomografias de feixe cônico e radiográficas foram em sua maioria concordantes, apresentando apenas algumas variáveis com resultados insatisfatórios (capd, dpele e dpontalt). Para as variáveis categóricas e discretas houve concordância intra e interexaminadores de ótima a perfeita em ambos os métodos, já as variáveis contínuas apresentaram resultados de moderada a excelente. Conclui-se que: a metodologia proposta no presente trabalho, utilizando os parâmetros do trabalho de Tatlisumak et al. (2007), são aplicáveis e confiáveis em radiografias extrabucais (radiografias PA de crânio e radiografias laterais de face) e reconstruções axiais e coronais de TCFC para a identificação humana pelos seios frontais; a concordância intra e interexaminador nos parâmetros utilizados por Tatlisumak et al. (2007) com a modalidade de imagem TCFC varia de boa a excelente; e de moderada a excelente nas imagens radiográficas; há um maior poder de reprodutibilidade e precisão do método proposto utilizando as reconstruções axiais e coronais de TCFC, tendo as radiografias extrabucais também confiabilidade; a variável menos concordante na análise pelas imagens de TCFC é a medida capd (concordância ruim); já pelas imagens radiográficas são dpele e dpontalt (concordâncias ruins). Tal resultado indica que estes parâmetros são mais passíveis de erros por parte dos avaliadores, uma vez que deve-se utilizar vários pontos de referência para suas mensurações.
377

Avaliação tridimensional do côndilo mandibular em indivíduos pós-surto de crescimento pubertário após uso de Herbst bandado. / Three-dimensional evaluation of the mandibular condyle in individual post-pubertal growth outbreak after banded herbst use.

Almeida, Kélei Cristina de Mathias 17 March 2017 (has links)
Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-05T16:47:11Z No. of bitstreams: 1 TESE Doutorado Kélei.pdf: 2128690 bytes, checksum: 6d32a1eacad944a350a690a474e3afa7 (MD5) / Rejected by Ana Cristina Jorge null (anacris@fclar.unesp.br), reason: Solicitamos que faça as seguintes correções: 1) O sumário deve conter todas as seções e subseções da sua tese (Ex. 2.1 Articulação temporomandibular (ATM) , 2.2.......e demais subseções); 2) As keywords devem ser as apresentadas no DECS. As suas palavras chaves em inglês no DECs são : Malocclusion, Angle class II Orthotic devices Cone-beam computed tomography Imaging, three-dimensional 3) Na ficha catalográfica o número correto de páginas é 108 f ; 4) Nos metadados você assinalou que não recebeu financiamento. Porém, na sua tese você agradece ao apoio financeiro da Capes e da Fapesp. Lembre-se que no caso da Fapesp é obrigatório informar também o número do processo; 5) Você não preencheu o nome do seu Programa de pós graduação no metadados; 6) Também não preencheu no metadados a área de concentração. Atenciosamente on 2018-09-05T18:58:25Z (GMT) / Submitted by Kelei Cristina De Mathias Almeida (keleimathias.almeida@gmail.com) on 2018-09-12T02:42:13Z No. of bitstreams: 1 TESE Doutorado Kélei Almeida.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-09-12T13:08:39Z (GMT) No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) / Made available in DSpace on 2018-09-12T13:08:39Z (GMT). No. of bitstreams: 1 almeida_kcm_dr_arafo_int.pdf: 2132229 bytes, checksum: f4f99b7fff170f591582b5ec78cec062 (MD5) Previous issue date: 2017-03-17 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo prospectivo foi avaliar tridimensionalmente a remodelação e o deslocamento do côndilo mandibular na fossa articular nos indivíduos, pós-surto de crescimento pubertário, tratados com aparelho Herbst bandado. A amostra foi constituída por 24 indivíduos, de ambos os gêneros, leucodermas, com idade cronológica média de 16 anos e 1 mês. Os indivíduos foram tratados com aparelho Herbst bandado por um período de 8 meses (média da amostra: 9,8 meses). Para a avaliação da remodelação do côndilo mandibular foram utilizadas tomografias computadorizadas de feixe cônico (TCFC) em dois tempos, denominados de T1 (antes da colocação do aparelho e T2 (após a remoção do mesmo). As tomografias foram obtidas pelo tomógrafo i-CAT Classic e os dados foram exportados no formato DICOM (Digital Image and Comunication in Medicine) e avaliados no programa Dolphin® Imaging 11.5 Premium. As medidas foram analisadas nas imagens dos cortes multiplanares (planos coronal, sagital e axial) por um observador, previamente calibrado. Os dados obtidos foram calculados pelo sistema de coordenadas cartesianas tridimensionais em um programa de software Matlab desenvolvido pelo Departamento de Física e Biofísica, da Faculdade Estadual Paulista – UNESP de Botucatu. Para avaliar o grau de concordância entre as mensurações empregouse o coeficiente de correlação intraclasse (ICC). À exceção das medidas FOE (eixo Z), C1E (no eixo X) e C2-T2 em ambos os lados, todas as demais medidas apresentaram alto grau de reprodutibilidade, denotando que o erro do método pode ser desprezado. O deslocamento dos côndilos, no sistema de coordenadas cartesianas, foi calculado com o Ponto Zero na Base do crânio; a remodelação foi calculada com o Ponto Zero na média da distância dos forames mentuais direito e esquerdo, forneceu uma análise quantitativa e qualitativa e distâncias euclidianas. Com relação a base do crânio, o côndilo direito se deslocou de forma moderada (0,71mm) para baixo e de forma relevante (0,91mm) para frente; o côndilo esquerdo se deslocou de forma relevante (0,93mm) para baixo e de forma moderada (0,73mm) para frente. O côndilo direito remodelou de forma relevante 1,08mm para trás e se distanciou da média da distância dos forames mentuais de forma relevante (1,19mm); o côndilo esquerdo remodelou de forma relevante 0,98mm para cima e se distanciou da média da distância dos forames mentuais de forma relevante (0,93mm). Foram mensurados os espaçamentos entre os pontos nos côndilos direito e esquerdo, em relação a fossa articular, sendo observado aumento de forma média, do espaçamento superior do côndilo esquerdo (0,34mm). O tratamento não promoveu alterações significantes nas medidas no eixo X, constatando que não houve movimento de lateralidade. Conclui-se que, com relação a base do crânio, os côndilos direito e esquerdo se deslocaram para baixo e para frente. O côndilo direito remodelou para trás enquanto que o côndilo esquerdo remodelou para cima. / The aim of this prospective study was to evaluate in 3-D the remodeling and displacement of the mandibular condyle in the glenoid fossa in the individuals, post-pubertal growth outbreak, treated with the banded Herbst appliance. The sample consisted of 24 individuals of both genders, leucoderma, with a mean chronological age of 16 years and 1 month. Subjects were treated with banded Herbst appliance during 8 months. Cone beam computed tomography (CBCT) was performed in two times to evaluate the condylar remodeling: T1 (prior to placement of the device) and T2 (after removal).) CT scans were obtained by i-CAT tomography Classic and the data were exported in DICOM (Digital Image and Communication in Medicine) format and evaluated in the Dolphin® Imaging 11.5 Premium program. The measurements were analyzed in multiplanar sections images (coronal, sagittal and axial planes) by an observer, previously calibrated. The data obtained were calculated by 3-D Cartesian coordinate system in a Matlab software, developed by the Department of Physics and Biophysics, UNESP Botucatu. To evaluate the agreement degree between the measurements, the intraclass correlation coefficient (ICC) was used. With the exception of the measurements FOE (Z axis), C1E (X axis) and C2-T2 on both sides, all other measurements showed a high degree of reproducibility, denoting that the error of the method can be neglected. The displacement of the condyles in the Cartesian coordinate system was calculated with the Zero Point in the skull base; the remodeling was calculated with the Point Zero in the mean distance of the right and left mental foramina, provided a quantitative and qualitative analysis and Euclidean distances. In relation to skull base, the right condyle moved moderately (0.71 mm) downwards and significantly (0.91 mm) forward; the left condyle shifted significantly (0.93mm) downwards and moderately (0.73mm) forward. The right condyle significantly remodeled 1.08mm behind and distanced itself from the mean distance of the mental foramina significantly (1.19mm); the left condyle significantly reshaped 0.98mm upward and distanced itself from the mean distance of the mental foramina significantly (0.93mm). The spacing between the points on the right and left condyles were measured, in relation to the glenoid fossa; there was a mean increase in the superior space of the left condyle (0.34 mm). The treatment did not promote significant changes in the measurements on the X axis, noting that there was no laterality movement. It was concluded that, with respect to the skull base, the right and left condyles moved downwards and forward. The right condyle remodeled backwards while the left condyle remodeled upward. / 2010/17934-8
378

AVALIAÇÃO DAS ALTERAÇÕES DENTOESQUELÉTICAS DECORRENTES DO TRATAMENTO DA MALOCLUSÃO DE CLASSE II COM O APARELHO FORSUS&#63194; POR MEIO DE TOMOGRAFIA COMPUTADORIZADA / DENTOALVEOLAR AND SKELETAL EFFECTS OF FORSUS APPLIANCE IN THE TREATMENT OF CLASS II MALOCCLUSION, EVALUATED BY COMPUTED TOMOGRAPHY

Sakuno, Antonio Carlos 22 March 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:15Z (GMT). No. of bitstreams: 1 Antonio Carlos Sakuno.pdf: 1476502 bytes, checksum: 802e1bb3fa7e7785095586a6debaa817 (MD5) Previous issue date: 2011-03-22 / This study aimed to evaluate cephalometrically, by means of Cone Beam Computed Tomography (CBCT), the dentoalveolar and skeletal effects of Class II correction ith the Forsus® appliance. Study group was composed by 10 patients, 7 males and 3 females, with initial mean age of 16,1 years, with at least ½ Class II, minimum overjet of 5mm, no supernumeraries, anodontia or permanent teeth loss. Facial pattern should be meso or brachyfacial. Patients were evaluated and it was shown they were at stage IV or V of bone maturation, seen by cervical vertebrae. Forsus utilization period was 7,16 years on average, with a CBCT (T1) before and another one (T2) after the removal of Forsus. Paired t-test was used for statistical analysis. Results showed a decrease of SNA and a small grown of mandible, what improved maxillomandibular relationship; there was a counter-clockwise mandibular rotation and a clockwise rotation of the occlusal plane. Upper incisors were retruded, retroclined and extruded, and upper molars showed distal angulation. Lower incisors were proclined and intruded, and lower molars were mesialized and extruded. So, Forsus appliance showed to be effective in Class II correction, proportioning more dentoalveolar alterations than skeletal changes. / Este estudo teve como objetivo avaliar cefalometricamente as alterações dentoesqueléticas decorrentes do tratamento da maloclusão de Classe II, divisão 1, com o aparelho Forsus®, por meio de Tomografia Computadorizada de Feixe Cônico (TCFC). O grupo avaliado foi composto por 10 pacientes, sendo 7 do sexo masculino e 3 do sexo feminino, com idade média de 16,1 anos, maloclusão com severidade mínima de 1/2 Classe II, trespasse horizontal mínimo de 5 mm, padrão facial meso ou braquifacial. Estes jovens se encontravam no estágio IV ou V de maturação óssea, verificada pelas vértebras cervicais. O tempo de uso do aparelho Forsus foi de 7,16 meses (média), período de avaliação compreendido entre a aquisição da primeira teleradiografia gerada através da TCFC (T1 - pré-Forsus) e da segunda teleradiografia (T2 - pós-Forsus). Para análise estatística foi utilizado o teste-t pareado. Os resultados mostraram um pequeno crescimento mandibular que, juntamente com uma diminuição do SNA levaram a uma melhora da relação maxilomandibular. Houve uma rotação no sentido anti-horário da mandíbula e do plano oclusal no sentido horário. Os incisivos superiores foram retruídos, verticalizados e extruídos e os molares superiores distalizaram por inclinação. Houve vestibularização, protrusão e intrusão dos incisivos inferiores, além de mesialização e extrusão dos molares inferiores. Desta maneira, conclui-se que o aparelho Forsus foi efetivo na correção da maloclusão de Classe II, propiciando maiores alterações dentoalveolares do que esqueléticas.(AU)
379

AVALIAÇÃO TOMOGRÁFICA DA ANGULAÇÃO DOS PRIMEIROS E SEGUNDOS MOLARES E DO ESPAÇO PARA O TERCEIRO MOLAR SUPERIOR APÓS O USO DO APARELHO FORSUS®. / EVALUATION OF UPPER FIRST AND SECOND MOLARS ANGULATION AND THE SPACE FOR THIRD MOLAR AFTER USING THE FORSUS® APPLIANCE.

Lima, Carolina Souto 29 March 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:16Z (GMT). No. of bitstreams: 1 1 CAPA E FOLHA DE ROSTO.pdf: 8768 bytes, checksum: 995763bdcb7f03d5aae11a4cf0972b49 (MD5) Previous issue date: 2011-03-29 / The present study aimed to assess the mesiodistal angle, upper first and second molars distalization and the space for upper third molars in patients treated with Forsus® associated to fixed appliance. Sample consisted of 44 lateral cephalograms (22 right side, and 22 left side) obtained from 11 Cone-Bean Computed Tomography (CBCT) of 11 patients, in two phases: before (T1) and after (T2) the Forsus®. appliance. After obtaining the lateral cephalograms, points, lines and planes were marked, to measure the variables of interest. For evaluation of the space for upper third molars, it was used a reference line (PTVR), from point PTV, perpendicular to Frankfurt plane, measuring the distance until the distal face of first and second upper molars. To evaluate the long axis of upper first and second molars, it was measured the angle formed between such teeth and the palatal plane. The software used was Radiocef Studio 2 and for statistical analysis it was used paired "t" test. Results showed there was distalization and distal tipping of upper first and second molars, with a greater magnitude in first molars. Alterations in right and left sides were similar. It was also noticed that there was a reduction in the probability of eruption of third molars. / A presente pesquisa avaliou a angulação mésio-distal e a distalização dos primeiros e dos segundos molares superiores permanentes em pacientes tratados com o aparelho Forsus® em conjunto com o aparelho ortodôntico fixo. A amostra foi composta por 44 teleradiografias, (22 do lado direito e 22 do lado esquerdo), obtidas por meio de 11 tomografias computadorizadas, de 11 pacientes, realizadas em dois tempos: antes (T1) e após (T2) a instalação do aparelho Forsus®, tratados na clínica de Pós-Graduação em Odontologia, área de Ortodontia, da Universidade Metodista de São Paulo. Após a obtenção dos cortes tipo telerradiografia, foi realizada a marcação dos pontos, linhas e planos, e realizada a mensuração das variáveis de interesse. Para avaliação do espaço para os terceiros molares superiores, utilizou-se uma linha referencial (linha PTVR), demarcada a partir do ponto PTV, perpendicular ao plano de Frankfurt. O espaço avaliado compreendeu entre a Linha PTVR, até a face distal do primeiro molar e do segundo superior permanente. Para avaliar o longo eixo dos primeiros e segundos molares superiores, mensurou-se o ângulo formado entre esses dentes e o plano palatino. Para auxílio das mensurações, foi utilizado o software Radiocef Studio 2. Na análise estatística usou-se o teste t pareado. Concluiu-se que houve distalização e aumento da angulação distal dos primeiros e segundos molares superiores, sendo que nos segundos molares a distalização e angulação distal da coroa ocorreram em menor quantidade; os efeitos do lado direito e esquerdo foram semelhantes; pode-se também constatar que ocorreu uma redução na probabilidade de erupção dos terceiros molares superiores.
380

AVALIAÇÃO DAS TÁBUAS ÓSSEAS VESTIBULARES E LINGUAIS DOS DENTES ANTERIORES INFERIORES E MOLARES SUPERIORES APÓS O TRATAMENTO COM OS APARELHOS FUNCIONAIS FIXOS FORSUS E TWIN FORCE BITE CORRECTOR / EVALUATION OF THE PLATES OF BONE BUCCAL AND LINGUAL LOWER ANTERIOR TEETH AND UPPER MOLARS AFTER TREATMENT WITH FUNCTIONAL FIXED APPLIANCES FORSUS AND TWIN FORCE BITE CORRECTOR

Bach, Cleimar Carlos 08 April 2011 (has links)
Made available in DSpace on 2016-08-03T16:31:16Z (GMT). No. of bitstreams: 1 Cleimar Carlos Bach.pdf: 2938306 bytes, checksum: 2ce02c5aa2704ece779a1f47c260b32b (MD5) Previous issue date: 2011-04-08 / Because the consequences of the use of fixed orthopedic appliances on buccal and lingual periodontal bone are still a mystery to the orthodontist and to the clinical research, this study aimed to evaluate, using cone beam computed tomography (CBCT) changes in thickness plates of buccal and lingual bone in first molars and lower incisors and canines, after the use of fixed appliances and Twin Force (Group A) or Forsus (group B) appliances for the treatment of Class II, Division 1 malocclusion. To this end, we obtained a sample of 22 young adults, divided into two groups, according to the mandible s propulsion device. The experimental group A: 11 patients, six male and five female, mean age of 15.09 years in the Twin Force installation, and 11 patients, seven male and four female, mean age of 15.45 years in the installation of Forsus. The average time of using the Twin Force was 3.73 months and Forsus, 7.09 months. Group A had CBCT before starting the treatment (T1), before installing the Twin Force (T2), after removing the Twin Force (T3) and in group B just before the installation of Forsus (T2) and after removal it (T3). For comparison between times T2 and T3 was used paired t test, and between times T1, T2 and T3 was used analysis of variance (ANOVA) one-criterion and a Tukey s post-hoc test. For comparison between groups was used the t -test. In the inter-groups comparison between the results showed no statistically significant difference between changes in bone thickness of buccal and lingual plates; on the other hand, in the intra-group evaluation, in 48 measures evaluated, in group A, were statistically significant reductions in the buccal cervical thirds of lower anterior teeth and upper first molars, and increased cervical and middle thirds on lingual lower anterior teeth, totaling 25 significant measures. In group B, there was a significant increase in lingual bone plate on lower anterior teeth and reduction on buccal upper molars, totaling only seven significant measures, but there was more significant measures of reduction bone in buccal cervical and middle thirds in the first upper molars, in comparison with group A. There was no significant difference between the measurements obtained with voxel 0.2 mm and 0.4 mm and no sexual dimorphism. The reductions on alveolar bone thickness, especially in cervical and middle thirds buccal teeth evaluated in this study is an alert to the clinician to do this periodontal diagnostic approach before starting the orthodontic treatment. / Pelo fato das consequências do uso de aparelhos ortopédicos fixos sobre o periodonto ósseo vestibular e lingual ainda serem uma incógnita para o ortodontista clínico e pesquisador, este estudo teve como objetivo avaliar, por meio de tomografia computadorizada de feixe cônico (TCFC) as alterações em espessura das tábuas ósseas vestibulares e linguais em primeiros molares superiores e incisivos e caninos inferiores, após a utilização de aparelhagem fixa e dos aparelhos Twin Force (grupo A) e Forsus (grupo B) para o tratamento da maloclusão de Classe II, 1ª divisão. Para tanto, obteve-se uma amostra de 22 pacientes jovens adultos, divididos em dois grupos, de acordo com o aparelho propulsor da mandíbula. Grupo experimental A: 11 pacientes, 6 masculinos e 5 femininos, com idade média de 15,09 anos na instalação do Twin Force, e 11 pacientes, 7 masculinos e 4 femininos, com idade média de 15,45 anos na instalação do Forsus. O tempo médio de uso do aparelho Twin Force foi de 3,73 meses e do Forsus, 7,09 meses. O grupo A realizou TCFC antes do início do tratamento (T1), antes da instalação do Twin Force (T2), após a remoção do Twin Force (T3); e o grupo B somente antes da instalação do Forsus (T2) e após a remoção do Forsus (T3). Para comparação entre os tempos T2 e T3 foi utilizado o teste t pareado e entre os tempos T1, T2 e T3 foi utilizada a Análise de Variância (ANOVA) a um critério e o teste post-hoc de Tukey. Para comparação entre os grupos foi utilizado o teste t . Na comparação intergrupos os resultados evidenciaram que não houve diferença estatisticamente significante entre as alterações das espessuras das tábuas ósseas vestibular e lingual; por outro lado, na avaliação intra-grupo, de 48 medidas avaliadas, no grupo A houve reduções estatisticamente significantes nos terços cervical e médio por vestibular, nos dentes anteroinferiores e nos primeiros molares superiores e aumento nos terços cervical e médio, por lingual nos dentes anteriores inferiores, totalizando 25 medidas significantes. Já no grupo B, houve aumento significante da tábua óssea lingual nos dentes anteriores inferiores e redução em vestibular nos molares superiores, totalizando apenas sete medidas significantes, mas com mais medidas significantes de redução óssea vestibular em terços cervical e médio nos primeiros molares superiores, em comparação com o grupo A. Não houve diferença significante entre as medições obtidas com voxel 0,2 mm e 0,4 mm e nem dimorfismo entre os gêneros. As reduções em espessura óssea alveolar, principalmente em terços cervicais e médios vestibulares nos dentes avaliados neste estudo são um alerta ao clínico, para que realize essa abordagem diagnóstica periodontal antes de iniciar o tratamento ortodôntico.

Page generated in 0.0632 seconds