Spelling suggestions: "subject:"Dental codels"" "subject:"Dental 2models""
1 |
An appraisal of 803 models of adult occlusions in terms of prevalence of malocclusion and need for treatment from a public health viewpointBergeron, Donald D. Boettner, Victor A. January 1900 (has links)
Thesis (M.S.)--University of Michigan, 1952.
|
2 |
Avaliação in vitro da precisão de técnicas de moldagens para implantes osseointegrados / In vitro evaluation of the accuracy of techniques of moldings for osseointegrated dental implantsBraga, Francisco Pantoja 16 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-16T00:42:59Z (GMT). No. of bitstreams: 1
Braga_FranciscoPantoja_M.pdf: 1746788 bytes, checksum: 2e92ba56c05af0022643d89add3ac42c (MD5)
Previous issue date: 2010 / Resumo: Este estudo In vitro teve como objetivo avaliar a precisão de quatro técnicas de moldagens para implantes ósseo integrados. A partir de uma matriz metálica contendo três implantes foi construída uma supraestrutura simulando uma prótese. As quatro técnicas estudadas foram assim separadas: Grupo A - 10 moldagens com transferentes cônicos (sem união) em moldeiras individuais fechadas; Grupo B - 10 moldagens com transferentes quadrados isolados em moldeiras abertas; Grupo C - 10 moldagens com transferentes quadrados unidos com resina autopolimerizável em moldeiras individuais abertas; Grupo D - 10 moldagens com transferentes quadrados unidos com resina composta Bis-acrílica autopolimerizável em moldeiras individuais abertas. O material de moldagem para todos os grupos foi o silicone de adição Honigum Mono (DMG) e o gesso utilizado para a fabricação dos modelos foi Resin Rock (Whip Mix-USA). Desajustes marginais foram avaliados entre a supra estrutura metálica parafusada aos modelos de trabalho obtidos a partir das moldagens utilizando-se microscópio óptico (aumento de 120X), assim como as tensões induzidas à supraestrutura, avaliadas por extensometria. Para a comparação dos grupos foi utilizado o teste não-paramétrico de Kruskal-Wallis com nível de significância de 5%, para a verificação de existência de diferença significativa entre os grupos com respeito às duas variáveis estudadas. Utilizou-se comparações múltiplas não-paramétricas, para indicar qual ou quais os grupos que levaram à significância estatística. O teste de Kruskal-Wallis para a variável tensão apresentou valor de p= 0,0043 e para a variável desajuste o p encontrado foi igual a 0,6073. Sendo 5% o nível fixado, foi possível observar que apenas para a variável tensão os grupos apresentaram diferença significativa entre si. Foi calculado o coeficiente de correlação de Pearson para as variáveis tensão e desajuste, indicando correlação positiva entre as variáveis. Esta correlação foi altamente significativa (p=0,0074). Os demais valores encontrados não apresentaram significância
estatística. Concluiu-se que a mais precisa dentre as quatro técnicas estudadas foi a que usou transferentes quadrados esplintados com bastões de resina pré- fabricados e que houve correlação direta entre desajuste marginal e tensões geradas à supraestrutura / Abstract: The main objective of this study in vitro is to evaluate the accuracy of four techniques of moldings implants osseointegrated. Starting from a metallic matrix with three implants, simulating a clinical situation, was constructed one super structure simulating one prosthesis. The four studied techniques were separated like this: Group A - 10 impressions with conic transfer in closed custom tray; Group B- 10 impressions with square transfer isolated in open custom tray; Group C- 10 impressions with square transfer splinted with autopolymerizing acrylic resin; Group D- 10 impressions taken with square transfer splinted with composite resin Bis-acrilic autopolymerizing in open custom tray. The impression taken material for all groups was vinyl polysiloxane Honigum (DMG), and the gypsum used was Resin Rock (Whip Mix-USA). Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope. The non-parametric test of Kruskal-Wallis was used to compare the 4 groups with a 5% level of significance to verify the significant difference among the groups with respect of the two studied variables. Multiple comparisons were used and they were non-parametric to indicate which group or groups will carry significance to statistics. The Kruskal-Wallis test as far as tension is concerned presented the value of p= 0.0043 and as far as misfit is concerned the p found was 0.6073. Being 5% the level established it is possible to observe that only the variable of tension in the groups show a significant difference among themselves. The correlated coefficient of Pearson was calculated between tension and misfit to each set of data in all the groups evaluated in the research, indicating positive correlation between tension and misfit. This correlation is highly significant (p-value 0.0074). The other values were not statistically significant. Conclusion: The most precise technique of the four was the one that used squared splinted transfers with prefabricated stick autopolymerizing acrylic resin and it had direct correlation between among misfit and tensions generated in the super structure / Mestrado / Protese Dental / Mestre em Clínica Odontológica
|
3 |
Confiabilidade de medidas realizadas em modelos virtuais obtidos a partir do escaneamento de moldagens e de modelos de gesso convencionais / Reliability of measurements performed on virtual models obtained from scanning of impressions and conventional plaster modelsMoreira, Debora Duarte, 1986- 22 August 2018 (has links)
Orientador: Gláucia Maria Bovi Ambrosano / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T09:24:55Z (GMT). No. of bitstreams: 1
Moreira_DeboraDuarte_M.pdf: 1498990 bytes, checksum: c7b7801745e1bf94bcf13b498805567b (MD5)
Previous issue date: 2013 / Resumo: O objetivo deste estudo foi comparar as medidas obtidas em modelos virtuais das moldagens e em modelos virtuais dos modelos de gesso com as obtidas em modelos de gesso. Os modelos virtuais foram obtidos pelo escaneamento da moldagem e do modelo de gesso em um scanner de superfície a laser (R700; 3Shape, Copenhage, Dinamarca) e as medidas foram realizadas com o software OrthoAnalyser (3Shape, Copenhage, Dinamarca). Os modelos de gesso convencionais foram mensurados com a utilização de um paquímetro digital. A amostra foi constituída de 26 pacientes selecionados aleatoriamente que foram submetidos a uma moldagem das arcadas superior e inferior com alginato e um registro de mordida com cera utilidade. As mensurações nos modelos de gesso, virtual da moldagem e virtual do modelo foram realizadas por três avaliadores devidamente treinados. Os dados foram tabulados e submetidos à análise estatística de correlação intraclasse para verificar a concordância das medidas intraavaliador e interavaliador e ao teste ANOVA para analisar diferenças nas medidas obtidas dos modelos virtuais da moldagem e do modelo. Os resultados mostraram existir diferença estatística significante (p?0,05) de 0,09 mm a 0,43 mm para dentes da região posterior e da região anterior e de 0,51 mm a 1,13 mm para perímetro do arco superior e distância intercaninos inferior, se comparados os modelos virtuais com os modelos de gesso; porém essas diferenças foram consideradas clinicamente aceitáveis. Foi possível concluir que os modelos digitais são uma alternativa confiável aos modelos de gesso / Abstract: The aim of this study was to compare measurements of digital models obtained from plaster models scans, alginate impression scans to those obtained from conventional plaster models. The plaster models and alginate impressions were scanned using a optical surface scanner (R700; 3Shape, Copenhage, Dinamarca) and the measurements were performed using proprietary software OrthoAnalyser (3Shape, Copenhagen, Denmark). The plaster models ware measured by using a caliper. The sample was comprised of 26 pacients randomly selected to have impressions of their upper and lower jaws taken using alginate and their bite registration using a wax bite. The measurements on the plaster model, digital impression and digital model were performed by three observers calibrated. The data was analyzed statistically by the intraclass correlation to assess the agreement of the measurements for the intra and inter-observers. ANOVA test was used to analyze the differences between the three different objects (plaster model, digital model from plaster and digital model from impression). The results showed there is a statistically significant difference (p?0,05) 0,09 mm to 0,43 mm to the posterior teeth and the anterior region, and 0,51 mm to 1,13 mm to upper arch length and lower inter-canine distance if compared digital models with plaster models, but these differences were found to be clinically acceptable. We concluded that the measurements taken from digital models can be a reliable alternative to conventional plaster models for orthodontic diagnosis purposes / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
|
4 |
Morfoanálise tridimensional dos arcos dentários de crianças com fissura completa de lábio e palato unilateral / 3D morphology of dental arches in children with complete cleft lip and unilateral palateBerbert, Christiane Camargo Villela 03 December 2018 (has links)
O objetivo deste trabalho foi realizar uma avaliação das áreas e das medidas lineares dos arcos dentários de crianças com fissura de lábio e palato unilateral (FLPU), aos cinco anos de idade. A amostra foi composta de 60 modelos digitais de maxila e de mandíbula de crianças com FLPU (p=30) (Grupo 1) e pacientes sem fissura (p=30) (Grupo 2). Os modelos de gesso foram digitalizados, por meio do Scanner 3 Shapes R700TM. Foram avaliadas as medidas lineares transversais (C-C) e ( M-M), lineares longitudinais (I-2MD), (I-2ME) e perpendicular (I-CC) e (I-MM) pelo Software Appliance Designer. As aferições das áreas total e parciais dos arcos dentários nos grupos de estudo foram pontuados e avaliados pelo Software do Sistema Estereofotogrametria. Para as análises dos resultados foi aplicado o Teste t , para verificar as alterações ocorridas entre os grupos, considerando o nível de significância de 5%. Os resultados demonstraram nas crianças com FLPU, um efeito retrusivo maxilar, pela menor dimensão linear I-CC e I-MM. Também um menor crescimento maxilar transversal anterior (C-C) e menores dimensões oblíquas anteriores direita (I-C) e esquerda(I-C) e oblíquas antero-posteriores (I-M e I-M). Pela avaliação das áreas maxilares, verificou-se uma menor área total e parcial anterior no grupo FLPU, comprovando que a retrusão maxilar ocorre preponderante na região da pré maxila. Um maior crescimento mandibular tanto pelas maiores medidas lineares transversal anterior (C-C), como pelas maiores medidas (I.C-C e I.M-M), além de maior área total e parcial posterior, comprovando a tendência de crescimento protrusivo inferior. Pela sobreposição de medidas de área total maxilo-mandibulares, constatou-se a restrição do crescimento maxilar e um excesso de crescimento mandibular no grupo FLPU. A comparação entre as medidas dos lados com e sem no grupo FLPU, permitiu verificar que na maxila, as medidas anterior e total do lado sem fissura são maiores do que as do lado com fissura. Na mandíbula, as medidas posterior (O.C-M ) e antero-posterior (O. I-M) foram maiores do lado sem fissura. Na avaliação da simetria entre os lados, o grupo FLPU demonstrou, na mandíbula, assimetria estatisticamente significante para maior do lado oposto à fissura maxilar. Isso permite denotar diferenças no crescimento latero-lateral pós cirurgias de queiloplastia e de palatoplastia na maxila e na mandíbula de crianças com FLPU, aos cinco anos de idade. Conclusão: Pode-se contabilizar alterações no crescimento de crianças com FLPU operadas, aos cinco anos de idade. Representado por: 1) Uma retrusão maxilar, dado pela menor área parcial anterior (AMaxA)(p<0,001). 2) Uma protrusão mandibular, pela maior área parcial posterior (AMandP)(p<0,001). 3) Um crescimento assimétrico maxilar, maior do lado com fissura. 4) Um significante crescimento assimétrico mandibular, mais acentuado no lado contrário à fissura (p<0,001 para C-M e para I-M). / The objective of this study was to perform an evaluation of the total and partial areas and linear, transverse, longitudinal and oblique measurements of the dental arches of children with cleft lip and unilateral palate (FLPU) at five years of age. The sample consisted of 60 digital models of maxilla and mandible of children with FLPU (p = 30) (Group 1) and patients without fissure (p = 30) (Group 2). Gypsum models were scanned using Scanner 3 Shape\'s R700TM. The measurements of the dimensions of the dental arches were: linear (C-C \') and (M-M\'), linear (I-2MD), (I-2ME) and perpendicular I-MM \') by Software Appliance Designer. The measurements of the total and partial areas of the dental arches in the study groups were scored and evaluated by the Software of the Stereophotogrammetry System. For the analysis of the results the Test t was applied to verify the changes that occurred between the groups. The level of significance of 5% was considered. The results showed in children with FLPU, a maxillary retrusive effect, by the smaller linear dimension I-CC \'and I-MM\'. Also lower anterior transverse maxillary growth (C-C \') and smaller anterior oblique dimensions (IC) and left anterior (I-C\') and oblique antero-posterior anterior. (I-M and I-M \'). By the evaluation of the maxillary areas, there was a smaller total and partial anterior area in the FLPU group, proving that maxillary retrusion preponderates in the premax region. A higher mandibular growth was observed in both the greater anterior (C-C \') linear measurements and the larger measures (IC-C\' and IM-M \'), as well as a larger posterior and partial area, denoting the protrusive growth tendency overlapping of maxillomandibular total area measurements, the restriction of maxillary growth and an excess of mandibular growth in the FLPU group were found. The comparison between the left and right side measurements in the FLPU group showed that in the maxilla, anterior and total measurements on the non-cleft side are greater than those on the cleft side. In the mandible, the posterior (O.C-M) and anteroposterior (O.I-M) measurements were larger on the non-cleft side. Conclusion: It was possible to denote differences in laterolateral and sagital growth after surgery of cheiloplasty and palatoplasty in the maxilla and in the mandible of children with FLPU at five years of age. Accounted by: 1) A maxillary retrusion, given by the smallest anterior partial area (AMaxA) (p <0.001). 2) A mandibular protrusion, by the largest posterior partial area (AMandP) (p <0.001). 3) Asymmetric maxillary growth, greater on the cleft side. 4) A significant asymmetric mandibular growth, more pronounced on the opposite side to the cleft (p <0.001 for CM and for I-M).
|
5 |
A stereophotogrammetric study of displaced mucosal tissue a thesis submitted in partial fulfillment ... in denture prosthesis ... /Cotter, Wilfred A. January 1969 (has links)
Thesis (M.S.)--University of Michigan, 1969.
|
6 |
A stereophotogrammetric study of displaced mucosal tissue a thesis submitted in partial fulfillment ... in denture prosthesis ... /Cotter, Wilfred A. January 1969 (has links)
Thesis (M.S.)--University of Michigan, 1969.
|
7 |
Accuracy and reliability of plaster models vs electronic modelsBerchtold, Thomas E. January 2010 (has links) (PDF)
Thesis (M.S.)--University of Alabama at Birmingham, 2010. / Title from PDF title page (viewed on June 25, 2010). Includes bibliographical references (p. 29-31).
|
8 |
Exatidão, precisão e reprodutibilidade de medidas dentárias em modelos de gessso e imagem tridimensionalGrehs, Betina [UNESP] 18 September 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:35Z (GMT). No. of bitstreams: 0
Previous issue date: 2009-09-18Bitstream added on 2014-06-13T18:50:52Z : No. of bitstreams: 1
grehs_b_me_arafo.pdf: 379410 bytes, checksum: 286c0b5c362ef542816e44d51525ebed (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O presente projeto desenvolvido em dois estudos visa avaliar: 1- a exatidão, precisão e reprodutibilidade de medições obtidas em modelos de gesso utilizando diferentes instrumentos de medidas e 2 –avaliar a influência do posicionamento da moldeira durante o tempo de presa do gesso na distorção dos modelos. Trinta modelos de gesso foram selecionados de maneira aleatória, preenchendo os seguintes requisitos de inclusão da amostra: 1)Presença dos incisivos, caninos, pré-molares e os primeiros molares permanentes em ambas as arcadas maxilar e mandibular; 2) Todos os dentes dos modelos terão que exibir morfologia normal; 3)Ausência de irregularidades no gesso proveniente de lesões cariosas e restaurações que possam afetar o diâmetro mésio-distal ou buco-lingual da coroa dentária; 4) Nenhum tratamento ortodôntico prévio. No estudo 1 as medições foram realizadas com três instrumentos: 1-Paquímetro digital da marca Mitutoyo Digimatic®, Mitutoyo (UK) Ltd, com os modelos posicionado sobre uma superfície plana; 2- Sistema MicroScribe 3DX (Immersion, San Jose, Calif): é um scanner 3D que grava a localização do ponto identificado com a extremidade de uma caneta. Colocando essa caneta em vários pontos do objeto a ser medido, o usuário pode coletar as coordenadas destes pontos e criar um modelo tridimensional. A digitalização é realizada com os modelos fixos num dispositivo preso a uma superfície plana. 3- Sistema O3d (widialabs©) no qual os modelos de gesso são escaneados utilizando-se um scanner de varredura produzindo uma imagem tridimensional. Com auxílio do software do programa os pontos a serem medidos são identificados e as medidas automaticamente registradas. As medidas lineares foram: tamanho dos dentes, trespasse horizontal, trespasse vertical, comprimento do arco, largura... / The objective of the present work separated in two parts: 1- is to assess accuracy, precision and reproducibility of measurements obtained from plaster models by means of different instruments; 2 – evaluate the influence of tray position during the setting time of gypsum at model distortion. Thirty plaster models will be randomly chosen according to the inclusion requirements of the sample as follows: 1) Presence of incisors, canines, pre-molars and the permanent first molars in both maxillary and mandibular arches; 2) Normal morphology on every tooth of the models; 3) Absence of irregularities on the plaster due to carious lesions and restorations which may affect the mesiodistal or buccolingual diameter of the dental crown; 4) No previous orthodontic treatment. Three instruments will be used to make the measurements: 1- Mitutoyo Digimatic® digital pachymeter, Mitutoyo (UK) Ltd: position models on a flat surface and measure them manually; 2- MicroScribe 3DX System (Immersion, San Jose, Calif.) : with MicroScribe , a 3D scanner , register the location of a selected point marked with one end of a pen. By placing the pen on different points of the object to be measured, one can collect the coordinates and make a three dimensional model. Digitizing is performed by fixing the models on a device fixed on a flat surface. 3- O3d System (widialabs©): the plaster models image is scanned by means of a scanning scanner, thus creating a three dimensional image. With the help of the program software the points to be measured are identified and the measurements are automatically recorded. Linear measurements to be assessed are as follows: size of teeth, horizontal overlap, vertical overlap, arch length and arch width. From the collected data, dependability of both Little irregularity index and Bolton analysis will... (Complete abstract click electronic access below)
|
9 |
Precisão das técnicas de moldagem e vazamento para próteses implantossuportadasDel'Acqua, Marcelo Antonialli [UNESP] 03 May 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-05-03Bitstream added on 2014-06-13T19:37:32Z : No. of bitstreams: 1
delacqua_ma_me_arafo.pdf: 2803470 bytes, checksum: c3da6f0cf6b27aff80e479e792d68cd7 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo... / Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below)
|
10 |
Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados /Muñoz Chávez, Alejandro. January 2007 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: Sergio Sualdini Nogueira / Banca: Mauro Antônio de Arruda Nóbilo / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below) / Mestre
|
Page generated in 0.0679 seconds