• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 8
  • 1
  • Tagged with
  • 39
  • 39
  • 28
  • 26
  • 13
  • 13
  • 13
  • 12
  • 11
  • 11
  • 10
  • 9
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Confiabilidade de diferentes métodos de aquisição de modelos dentários digitais / Reliability of different methods of acquiring digital dental casts / Reliability of different methods of acquiring digital dental casts

George Nunes Bueno 29 January 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O uso de modelos de estudo dentários faz parte tanto da prática quanto da pesquisa odontológica e ortodôntica. Com a introdução dos scanners 3D e dos tomógrafos CBCT (cone beam computer tomography) tornou-se possível a obtenção de modelos dentários tridimensionais virtuais das arcadas dentárias. Foram selecionados 56 modelos dentários superiores e escaneados em três tipos diferentes de scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italia), 3Shape R700 3D Scanner (3Shape, Copenhagen, Dinamarca) e o scanner 3Shape TRIOS (3Shape, Copenhagen, Dinamarca). Doze medidas foram realizadas nos modelos dentários de gesso e comparadas com as mesmas medidas realizadas nos modelos dentários digitais por meio do teste de Análise de Variância (ANOVA). Estatisticamente não foram encontradas diferenças significativas entre as medições tradicionais nos modelos dentários de gesso e as medidas realizadas nos modelos dentários digitais. Os três tipos de métodos de aquisição de modelos dentários digitais foram considerados confiáveis para as medições horizontais, transversais e verticais. Os modelos dentários virtuais podem ser indicados como substitutos dos modelos dentários de gesso. / The use of dental study casts is part of the practice and research in dentistry and orthodontics. With the advent of 3D scanners and CBCT (cone beam computer tomography) scanners, it became possible to obtain three-dimensional virtual dental casts of the dental arches. 56 upper dental casts were selected and scanned in three different types of scanners: Maestro 3D Dental Scanner (AGE Solutions, Potedera, Italy), 3Shape R700 3D Scanner (3Shape, Copenhagen, Denmark) and 3Shape TRIOS scanner (3Shape, Copenhagen, Denmark). 12 Measurements were performed on dental plaster models and compared with the same measurements in digital dental models through test Analysis of Variance (ANOVA). No statistically significant differences were found between the traditional measurements in dental plaster models and measurements taken in the digital dental models. The three kinds of methods to acquire digital dental models were considered reliable for horizontal, vertical and cross measurements. The virtual dental models can be indicated as substitutes for dental plaster models.
22

Analysis of accuracy and mechanical properties of 3D-printed polymeric dental materials

Alshaibani, Raghdah Mohammedali 28 May 2024 (has links)
OBJECTIVES: The objective was to investigate the accuracy, storage stability, and mechanical properties of 3D-printed polymeric dental materials. MATERIALS AND METHODS: Three completely dentate models, two maxillary and one mandibular each with their respective die, and three implant models were designed using dental CAD software (3SHAPE DENTAL SYSTEM). A horseshoe-shaped solid base with a posterior horizontal bar was utilized. The models were printed based on the manufacturer's instructions for four weeks using six printers with the corresponding recommended resin materials: Carbon M2 (DPR10), HeyGears A2D4K (Model HP UV2.0), Stratasys J5 (MED610), Stratasys Origin One (DM200), Envision One (E-Model LightDLP), and Asiga Pro4K (VeriModel) with a standard layer thickness of 50 μm (N=72). The models were scanned after printing using Sirona inEOS X5 scanner, while the implant models were scanned using a CT scanner (GE Phoenix V|tome|x metrology edition). The full arch models were randomly assigned to three groups of storage conditions: cold environment (LT, 4 ± 1°C), hot and dry environment (HT, 50 ± 2°C), and room temperature (RT , 25 ± 2°C, serving as the control). Each group was kept under the designated conditions and scanned at 1, 2, 3, 4, and 8 weeks. The generated STL files were imported into a 3D inspection software for comparison with the original STL files. Four sets of reference points (central fossa of first premolars and central fossae of second molars) were selected to determine six distances of inter-arch segments, from which the inter-arch distance trueness and precision deviation were measured. For the second part of the study, maxillary Lucitone Digital Print denture base (DB) (N=5), maxillary Lucitone IPN 3D Premium anterior and posterior teeth (N=6), and maxillary Keystone Keysplint Soft Clear occlusal splint (N=5) were printed using two printers (Carbon M2, Asiga Max UV) with a standard layer thickness of 50 μm for denture base and teeth, and 100 μm for the occlusal splint. The tolerance threshold was set to 50 μm for Lucitone IPN and 100 μm for Lucitone DB and Keysplint Soft. In-tolerance percentage and deviation RMS were obtained and analyzed with multivariate least square mean linear regression using JMP Pro 17 (SAS, Cary, NC) to identify significant effects (α=0.05). The third part investigated the mechanical properties of Lucitone DB and IPN using 2 printers (Carbon M2, Asiga Max UV) as follows: flexural strength (N=10) using a threepoint bend test, fracture toughness (N=10), creep (N=5), Vickers hardness test (N=15), surface roughness (N=15), while Shore A hardness (N=15) and tensile strength (N=10) were performed for Keysplint Soft Clear. Data were analyzed using one-way and multivariate least square mean linear regression followed by Tukey’s HSD test using JMP Pro 17 (SAS, Cary, NC) to identify significant effects (α=0.05). RESULTS: The in-tolerance percentage varied significantly among printers, with Carbon M2 (CAB) showing the highest values. Stratasys (J5) displayed the highest accuracy in term of precision, while HeyGears A2D4K (HGS), Carbon M2 (CAB), and Stratasys (J5) exhibited the highest accuracy in term of trueness. The inter-molar segment showed the highest deviation. No significant difference was observed in in-tolerance percentage across different print weeks except for week 2 in one printer (Stratasys Origin1). CAB exhibited a higher in-tolerance percentage for the DB than Asiga Max UV (ASG), with the fitting surface having the highest in-tolerance percentage. IPN anterior teeth had a higher intolerance percentage than posterior teeth, with ASG showing a higher value than CAB. No statistically significant difference was found in the in-tolerance percentage of Keysplint Soft Clear between ASG and CAB. Resin printed using ASG demonstrated higher flexural strength, Vickers hardness, and creep, while resin printer using CAB exhibited higher fracture toughness, with no significant difference in surface roughness between the two printers. Lucitone IPN had higher flexural strength and Vickers hardness, surface roughness , and lower creep and fracture toughness than Lucitone DB. CAB Keysplint Soft had higher tensile strength than ASG, with no statistically significant difference in Shore A hardness between the two printers. CONCLUSION: Model dimension deviations were impacted by storage conditions and the specific printer utilized, with high-temperature storage exhibiting the least stability. However, no significant difference was noted between low and room temperature storage conditions. Carbon M2 exhibited the highest level of accuracy. The of 3D-printed denture bases and denture teeth varied across different printers. Conversely, no significant difference in accuracy was observed for a soft occlusal splint between two printers. Materials printed using different printers showed statistically significant different mechanical properties.
23

Precisão das técnicas de moldagem e vazamento para próteses implantossuportadas /

Del'Acqua, Marcelo Antonialli. January 2005 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Marcelo Ferrarezi de Andrade / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem e vazamento para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Cônicos, Quadrados e Quadrados unidos) associadas a três técnicas de vazamento (Convencional, com tubos de Látex e com análogos unidos com Duralay) para próteses implantossuportadas. Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de latão simulando um arco inferior desdentado onde foram fixados provisoriamente quatro análogos de pilares Micro-Unit perpendicularmente à superfície e paralelos entre si, sendo denominados análogos A, B, C e D. Uma estrutura metálica foi confeccionada e parafusada a quatro novos análogos. Este conjunto foi cimentado passivamente no modelo mestre com resina epóxica. Foram confeccionadas (com 2 mm de alívio) uma moldeira individual de alumínio para a técnica com os transferentes quadrados unidos e outra para as técnicas com os transferentes cônicos e quadrados. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (Vel-Mix, Kerr), espatulado à vácuo. Foi obtido um total de cinquenta modelos, sendo cinco por técnica. A estrutura metálica foi parafusada com um torque de 10 Ncm em todos os modelos no análogo A, enquanto as medições das fendas formadas foram feitas nos análogos C e D. Este processo foi repetido no análogo D, anotando-se as medidas dos análogos A e B. Estas medições foram feitas por um programa (Leica QWin) que recebia as imagens de uma câmara de vídeo ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Among the countless clinical and laboratories procedures of a prosthetic treatment, the implant impression and pouring techniques for implant-supported restorations are still responsible for great concern and controversy among the researches. This study in vitro investigated the accuracy of a stone Index and of three impression techniques (tapered impression copings, squared impression copings and squared impression copings splinted with Duralay resin) associated to three pouring techniques (Conventional, with tubes of Latex and joining the analogs with Duralay resin) for an osseointegrated implant-supported prostheses. Conexão (Conexão Systems of Prosthesis) prosthetic components were used. A mandibular brass cast was constructed with four stainless steel implant abutments analogs 90° to the surface and parallel among themselves, being denominated analog A, B, C and D. A master framework was made and screwed to four new analogs, which were cemented passively into the model master with epoxy resin. This formed a metal implant cast with a passive implant framework fitted to it. An aluminum custom tray was fabricated for the technique copings splinted with Duralay and other for the techniques tapered and squared copings. Polyether impression material (Impregum Soft medium consistency - 3M ESPE) was used for all impressions. A total of fifty stone casts were formed by carefully vibrating improved dental stone (Vel-Mix, Kerr), mixed under vacuum, being five for technique. The standard framework was seated on each cast and guide pin was tightened in the analog A to 10 Ncm using a torque driver, while the measurements of abutment / framework interface gaps were made in analogs C and D. This process was repeated in analog D, being written down the measures of the analogs ones A and B. These measurements were analyzed using software (Leica QWin) that received the images of a video ...(Complete abstract, click electronic access below) / Mestre
24

Long-term follow up of rapid palatal expansion followed by edgewise orthodontics :

Hall, Bradley S. January 2008 (has links) (PDF)
Thesis--University of Oklahoma. / Bibliography: leaves. 129-134.
25

Avaliação da precisão das técnicas de moldagem para próteses implantossuportadas sobre implantes alinhados e implantes não-alinhados

Muñoz Chávez, Alejandro [UNESP] 28 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:38Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-03-28Bitstream added on 2014-06-13T19:58:14Z : No. of bitstreams: 1 munozchavez_a_me_arafo.pdf: 1098693 bytes, checksum: 17a654ba992a69bd6c38b4699551735e (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão de uma técnica de registro (Index) e de três técnicas de moldagem (transferentes Quadrados, Quadrados unidos e Quadrados com prolongamentos em forma de hélice) associadas a duas situações clinicas (análogos alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Duas estruturas metálicas de três elementos sendo três alinhados e três não-alinhados e vinte e uma moldeiras individuais de resina acrílica foram confeccionadas. O material de moldagem utilizado foi um poliéter (Impregum Soft Média Viscosidade - 3M ESPE) e o gesso empregado foi um gesso tipo IV (FujiRock -GC Corp), espatulado à vácuo. Foi obtido um total de vinte e um modelos, sendo sete por técnica, mais sete registros do index... / The present in vitro study compared the dimensional accuracy of a master cast (control group) with verification jig (Index) and 3 impression techniques (squared impression copings, squared impression copings splinted with autopolymerizing acrylic resin and squared impression copings with prolongations created from autopolymerizing acrylic resin in the vestibule-lingual direction). Materials and Methods. An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas, two passive implant frameworks and twenty-one identical custom impression trays were made with autopolymerizing acrylic resin... (Complete abstract, click electronic access below)
26

Avaliação tridensional da precisão das técnicas de moldagem para próteses implantossuportadas sobre pilares alinhados e não-alinhados /

Munhoz Cháves, Alejandro. January 2009 (has links)
Orientador: Francisco de Assis Mollo Junior / Banca: João Neudenir Arioli Filho / Banca: Sergio Sualdini Nogueira / Banca: Rafael Leonardo Xediel Consani / Banca: Pedro César Garcia de Oliveira / Resumo: Dentre as inúmeras fases clínicas e laboratoriais de um tratamento protético, as técnicas de moldagem para próteses implantossuportadas são ainda responsáveis por grande preocupação e controvérsia entre os pesquisadores. Este estudo in vitro teve como objetivo avaliar a precisão tridimensional das moldagens para próteses sobre implantes, utilizando-se a técnica direta, variando-se os transferentes (transferentes quadrados, transferentes quadrados com extensão vestíbulo-lingual, transferentes quadrados unidos com Duralay, transferentes quadrados unidos com barra de metal e Index), o tipo de material de moldagem (Impregum Soft média viscosidade, Express consistência regular - 3M ESPE) e a disposição dos implantes (alinhados e não-alinhados). Todos os componentes protéticos utilizados foram da empresa Conexão (Conexão Sistemas de Prótese). Foi construído um modelo mestre de resina epóxica simulando um arco inferior parcialmente desdentado onde foram fixados seis análogos de pilares Micro-Unit. Foi obtido um total de cinqüenta e seis modelos, sendo sete por técnica, mais sete registros do index. Estas medições tridimensionais foram feitas por um programa (ReflexSoft 1.0) que recebia as imagens StereoMicroscópio Reflex. Os valores de distorção médios obtidos foram: Index = 25,88μm (±3,41 SD); Quadrado/ Impregum = 80,22μm (±6,36 SD); Quadrado/ Express = 80,72 μm (±4,92 SD); Quadrado Duralay/Impregum = 84,63 μm (±9,22 SD); Quadrado Duralay/ Express =78,73 μm (±6,84 SD); Quadrado hélice/ Impregum = 30,72 μm (±3,53 SD); Quadrado Hélice/ Express = 30,21 μm (±4,08 SD); Quadrado Barra Metálica/Impregum = 57,08 μm (±5,96 SD); Quadrado Barra Metálica/ Express = 50,77 μm (±4,82 SD). Os testes estatísticos utilizados foram Holm-Sidak Method e Mann-Whitney (a=0,05). Pode-se concluir que em relação às técnicas estudadas que: ...(Resumo completo, cliar acesso eletrônico abaixo) / Abstract: An epoxy resin cast of a partially dentulous mandibular was fabricated with 6 abutment replicas. Nine groups were formed: (Index(I); squared impression copings/ Impregum (SI), metal splinted Impression copings/ Impregum (MI), Duralay splinted impression copings/Impregum (DI), Squared modified Impression copings/ Impregum (SMI), squared impression copings/ Express (SE), metal splinted Impression copings/ Express (ME), Duralay splinted impression copings/ Express (DE) and Squared modified Impression copings/ Express (SME) with 7 casts each were formed,. The measurements were analyzed using software that received the images of a video camera coupled Reflex microscope. Data were analyzed with a 1-way analysis of variance at α <.05, followed by the Holm-Sidak Method and Mann-Whitney test (α <.05). Results. The mean values of abutment/framework interface gaps were: I group 25,88μm (±3,41 SD); SI group 80,22μm (±6,36 SD); SE group 80,71μm (±4,92 SD); MI group 57,07μm (±5,96 SD); ME group 50,76μm (±4,82 SD); DI group 84,63μm (±9,22 SD); DE group 78,73μm (±6,84 SD); HI group 30,71μm (±3,53 SD); HE group 30,21μm (±4,08 SD). No significant difference was detected between I group and HI group, and between I group and HE group (P <.05). Did not exist superiority regarding the impression material. / Doutor
27

AVALIAÇÃO POR MEIO DE MODELOS VIRTUAIS TRIDIMENSIONAIS DAS DISTÂNCIAS INTERCANINOS E INTERMOLARES INFERIORES EM TRÊS MOMENTOS / Evaluation through three-dimensional virtual models of the alterations of the inferior intercanine and intermolar widths in patients treated orthodontically.

Viek, Roberto 28 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:11Z (GMT). No. of bitstreams: 1 Roberto Viek.pdf: 731404 bytes, checksum: d2b2835010e2893c6d296bcf98c35971 (MD5) Previous issue date: 2008-02-28 / The purpose of this study was to evaluate the stability of the orthodontic treatment in three distinct moments, by measuring the inferior intercanine and intermolar widths using three-dimensional virtual models as tools. Inferior arch cast models of 19 patients in three distinct phases were selected, pretreatment (T1), post treatment (T2) and minimum of 5 years post-contention (T3), adding up to 57 models, which were digitalized through Scanner 3D SCANTEH ST500 (SCAN technology A/S, CITY, Denmark), to obtain three-dimensional virtual models. In these three-dimensional virtual models, the distances between cuspids of the canines, called intercanine width and the distance between cuspids mesio-buccal of the first molars, called intermolar width, were selected and measured with the help of the software Rapidform (Inus Technology Inc). In order to do a statistical analysis, the analysis of variance of repeated measures was performed, and also, multiple comparisons of Bonferroni at significance level of 5% were performed. The intercanine and intermolar widths, on an average, decreased between T1-T2 and kept on decreasing between T2-T3. After 4 weeks, 20% of the sample was measured again to evaluate the fault of the method, where we can find average values similar to the ones found in the first measuring. In this study, by using threedimensional virtual models, it is possible to notice that there is no stability during and after the orthodontic treatment, concerning intercanine and intermolar widths.(AU) / O propósito desse estudo foi de avaliar a estabilidade do tratamento ortodôntico em três momentos distintos, por meio de mensuração das distâncias intercaninos e intermolares inferiores, utilizando, como ferramenta, modelos virtuais tridimensionais. Foram selecionados modelos de gesso da arcada inferior de 19 pacientes em três fases distintas: pré-tratamento (T1), pós-tratamento (T2) e mínimo de 5 anos pós-contenção (T3), totalizando 57 modelos, os quais foram digitalizados por meio do Scanner 3D SCANTEH ST500 (SCAN technology A/S, Dinamarca), para obtenção dos modelos virtuais tridimensionais. Nesses modelos virtuais tridimensionais foram selecionadas e mensuradas as distâncias entre as pontas de cúspide dos caninos, denominada distância intercaninos e pontas de cúspide mesiovestibulares dos primeiros molares, denominada distância intermolares, com o auxílio do programa Rapidform ( Inus Technology Inc,). Para a análise estatística, foi realizada a análise de variância de medidas repetidas, e realizadas comparações múltiplas de Bonferroni ao nível de significância de 5%. As distâncias intercaninos e intermolares, em média, diminuíram entre T1-T2 e continuaram diminuindo entre T2- T3. Após 4 semanas, 20% da amostra foi novamente mensurada para avaliação do erro do método, onde foram encontrados valores médios semelhantes aos encontrados na primeira mensuração. Nesse trabalho, utilizando-se modelos virtuais tridimensionais, nota-se que não há estabilidade durante e após o tratamento ortodôntico, no tocante às distâncias intercaninos e intermolares.
28

Precisão das técnicas de moldagem para próteses implantossuportadas /

Del'Acqua, Marcelo Antonialli. January 2009 (has links)
Resumo: Desde que não há consenso em relação a técnica de moldagem mais precisa, foi objetivo deste estudo in vitro avaliar a precisão de 1 técnica de registro (Index de resina composta) e de 5 técnicas de moldagem para próteses implantossuportadas (transferentes quadrados, quadrados jateados, quadrados com extensão lateral, quadrados unidos com Duralay e quadrados unidos com barra de metal) empregando-se 3 materiais de moldagem: silicone de polimerização por adição consistência densa/fluida com moldeira de estoque de inox, poliéter média viscosidade e silicone de polimerização por adição consistência regular com moldeira individual. Foram construídos 1 modelo mestre com 4 análogos de pilares Micro-Unit e 1 estrutura metálica. Obteve-se do modelo mestre um total de 45 modelos, sendo 5 por técnica. A estrutura metálica foi parafusada utilizando-se a técnica de mensuração de fendas por um parafuso. Estas medições foram feitas com o auxílio do programa Leica QWin que recebeu as imagens de uma câmara de vídeo acoplada a uma lupa com um aumento de 100 x. Os resultados obtidos foram analisados estatisticamente utilizando o teste de Kruskal-Wallis seguido pelo método de Dunn, !=0,05. Dentro das condições experimentais deste estudo, podese concluir que não houve diferença estatística entre: modelo mestre (31,63 !m), quadrado Impregum (38,03 μm), quadrado jateado Impregum (46,80 μm), Index (45,25 μm) e quadrado com extensão lateral Express consistência densa/fluida (51,20 μm), sendo esta a eleita. Devido aos piores resultados obtidos com as técnicas quadrado Express regular (151,21 μm) e quadrado jateado Express regular (136,59 μm), o material de moldagem Express consistência regular não deve ser empregado, sendo escolhido então para ser utilizado com moldeiras individuais o Impregum viscosidade média. Caso o cirurgião-dentista pretenda realizar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Since there is still no consensus regarding the most accurate impression techniques, it was the purpose of this study compared the dimensional accuracy of stone index and of 5 impression techniques for implant-supported prostheses (squared impression copings, modified squared, !squared sandblasted and coated with impression adhesive, modified squared, Duralay splinted and metal splinted) using 3 impression materials: vinyl polysiloxane putty/light body with a metal stock tray and polyether medium consistency and vinyl polysiloxane regular body were used with a custom aluminum tray. A master cast with 4 parallel implant abutment analogs and a framework were fabricated. Nine groups (n=5) were tested. The gap measurement method employed was just one titanium screw tightened to the framework. Group's measurements were analyzed using LeicaQWin software that received the images of a video camera coupled to a stereomicroscope at x100 magnification. The results were statistically analyzed with Kruskal-Wallis One Way ANOVA on Ranks test followed by Dunn's Method, !=.05. Under the conditions of this study the following conclusions could be drawn: no significant difference was detected among Master Cast (31.63 !m), Squared Impregum (38.03 !m), Sandblasted-Adhesive Squared Impregum (46.80 !m), Index (45.25 μm) and Modified Squared techniques (51.20 μm) (P=.05), being the elected. Due to the worst results with the techniques Squared Express Regular (151.21 μm) and Sandblasted-Adhesive Squared Express Regular (136.59 μm), the Express regular body impression material should not be used, and then chosen to be used Impregum Soft medium consistency with custom tray. If the dentist wishes to perform the technique with splinted copings (Metal Splinted = 68.55 !m and Duralay Splinted = 165.03 !m), the splint should be made with bars of metal. The impression technique using sandblasted-adhesive squared... (Complete abstract click electronic access below) / Orientador: Marco Antonio Compagnoni / Coorientador: Francisco de Assis Mollo Junior / Banca: Wellington Cardoso Bonachela / Banca: Ricardo Faria Ribeiro / Banca: Gelson Luis Adabo / Banca: João Neudenir Arioli Filho / Doutor
29

Comparação da estabilidade dos arcos dentários em pacientes com e sem fissura labiopalatina após tratamento ortodôntico/reabilitador / &nbsp;

Caballero, Jorge Tomasio 03 May 2018 (has links)
O propósito do presente estudo foi comparar as variações das dimensões lineares dos arcos dentários de pacientes com fissura labiopalatina após o tratamento ortodôntico e protético com prótese parcial fixa e pacientes sem fissura labiopalatina imediatamente após a ortodontia e pelo menos um ano após a remoção do aparelho ortodôntico. Este estudo longitudinal retrospectivo, foi composto por uma amostra de 70 modelos digitais, dos quais 30 modelos eram de pacientes com fissura labiopalatina unilateral completa, que receberam uma prótese parcial fixa na região da fissura (n=15), grupo fissura (GF); e 40 modelos de pacientes sem fissura labiopalatina (n=20), grupo controle (GC); com idade entre 18 e 30 anos. Os modelos foram obtidos em dois tempos: (T1) término do tratamento ortodôntico, e (T2) pelo menos 1 ano após a reabilitação protética (GF); e (T1) término do tratamento ortodôntico e (T2) pelo menos um ano após remoção do aparelho ortodôntico (GC). As medidas das dimensões dos arcos dentários foram realizadas diretamente nas imagens escaneadas, por meio do Scanner 3Shapes R700TM e mensuradas pelo Software Appliance Designer. As dimensões avaliadas foram: distância inter-caninos, distância inter-1os. pré-molares, distância inter-molares, e comprimento incisivo-molar. Um examinador previamente calibrado e treinado realizou as avaliações. Foram realizadas comparações entre os grupos, em tempos distintos (T1 e T2); e na diferença entre T2 e T1 nos grupos (GF e GC); utilizando o teste T ou de Mann- Whitney, com um nível de significância de 5% (p<0.05). Houve diferença estatística (p=0,005) no valor da variação de T2-T1 na distância inter-caninos com aumento da distância no GF e diminuição no GC. Na variação da distância inter-prémolar o GF apresentou diminuição do valor e o GC mostrou aumento, com diferença estatisticamente significativa (p=0,008). Nos demais parâmetros (inter-molar e incisivo molar) não houve diferença estatística. Não houve estabilidade no GC na distância inter-caninos e observou-se estabilidade no GF, não houve estabilidade no GF na distância inter-pré molar e houve estabilidade no GC. A Prótese Parcial Fixa estabiliza os resultados obtidos com a ortodontia. / The aim of the present study was to compare the linear dimensions of dental arches of patients with cleft lip and palate following orthodontic and prosthetic treatment with fixed partial denture and patients without cleft lip and palate immediately after orthodontics and at least one year after removal of the orthodontic appliance. This retrospective longitudinal study consisted of a sample of 70 digital models, of which 30 models were from patients with complete unilateral cleft lip and palate, who received a fixed partial prosthesis in the cleft region (n = 15), cleft lip and palate group (CLPG); and 40 patient models without cleft lip and palate (n = 20), control group (CG); aged between 18 and 30 years. The models were obtained in two stages: (T1) end of orthodontic treatment, and (T2) at least 1 year after prosthetic rehabilitation (CLPG); and (T1) end of orthodontic treatment and (T2) at least one year after removal of the orthodontic appliance (CG). Measurements of the dimensions of the dental arches were performed directly on the scanned images, using the 3Shape\'s R700TM Scanner and measured by the Appliance Designer Software. The dimensions evaluated were: inter-canine distance, inter-1st premolars distance, intermolar distance, and incisormolar length. A pre-calibrated and trained examiner performed the assessments. Comparisons were made between the groups at different times (T1 and T2); and in the difference between T2 and T1 in the groups (CLPG and CG); using the T or Mann- Whitney test, with a significance level of 5% (p <0.05). There was a statistical difference (p = 0.005) in the value of the T2-T1 variation in the intercanine distance with increase in the ClG distance and decrease in the CG. In the interprémolar distance variation the ClG presented a decrease in value and the CG showed an increase, with a statistically significant difference (p = 0.008). In the other parameters (intermolar and molar incisors) there was no statistical difference. There was not stability in the CG in the intercanine distance and there was stability in the CLPG, there was stability in the CG in the inter-pre-molar distance and there was no stability in the CLPG. Partial Fixed Prosthesis stabilizes the results obtained with orthodontics.
30

Evaluation of the dental arch in children with cleft lip and palate by means of 3D digital models / Avaliação dos arcos dentários de criança com fissura labiopalatina por meio de modelos digitais tridimensionais

Jorge, Paula Karine 15 July 2014 (has links)
The aim of this study was to evaluate the dimensional alterations of dental arches of cleft lip and palate children after cheiloplasty at two rehabilitation centers. The sample was composed of 94 digital models and divided in two groups: Group I 23 children, assisted at University of Zurich with presurgical orthopedic intervention (Hotz plate); Group II 24 children, assisted at Hospital for Rehabilitation of Craniofacial Anomalies of the University of São Paulo without presurgical orthopedic intervention. The three dimensional images were used to evaluate before lip repair (stage 1) and approximately 1 year old (stage 2). The obtained measures were: intercanine distance, intertuberosity distance, anterior-posterior arch distance, anterior-posterior cleft length, anterior and posterior cleft width. The comparison between stages 1 and 2 was evaluated in group I, group II and between group I and II. The alterations between groups were verified by Independent t test. If the sample did not present a normal distribution, Wilcoxon and Mann-Whitney tests were used. In Group I, the comparisons between stages 1 and 2 showed that the intertuberosity and anterior-posterior arch distance increased and the intercanine, anterior and posterior cleft distances decreased. In Group II, the comparisons between stages 1 and 2 showed that intertuberosity distance increased and intercanine, anteriorposterior cleft length distances, anterior and posterior cleft widths decreased. The comparison of the dimensional alterations of dental arches between the two rehabilitation centers exhibited differences: in the stage 1, the intercanine distance decreased in Group II; in the stage 2, the anterior cleft width, the intercanine distance and the anterior-posterior cleft length decreased in Group II, suggesting the superposition of maxillary segments; in Group II, there was a greater narrowing of the anterior and posterior cleft widths, suggesting that Hotz plate induced a more evenly and equidistant approximation of maxillary segments in Group I. It is worth emphasizing that more studies should be conduct to reduce the variability in treatment protocols for cleft lip and palate patients, thus assuring the best evidencebased treatment. / O propósito deste estudo foi avaliar as alterações dimensionais dos arcos dentários de crianças com fissura de lábio e palato após a queiloplastia em dois centros de reabilitação. A amostra foi composta por 94 imagens digitais de modelos de gesso, e dividida em dois grupos: Grupo I - 23 crianças, tratas na Universidade de Zurique, com intervenção ortopédica pré-cirúrigica (placa de Holtz); Grupo II - 24 crianças tratadas no Hospital de Reabilitação de Anomalias Craniofaciais da Universidade de São Paulo, sem intervenção ortopédica pré-cirúrgica. As imagens tridimensionais dos modelos de gesso foram avaliados antes da queiloplastia (estágio 1) e com aproximadamente 1 ano de idade (estágio 2). As seguintes dimensões foram obtidas: comprimento anteroposterior da fissura, amplitude anterior da fissura, amplitude posterior da fissura, comprimento anteroposterior do arco, distância intercaninos e distância intertuberosidades. As comparações foram realizadas entre os estágios 1 e 2 e entre os grupos I e II. As diferenças entre os grupos foram verificadas pelo teste t independente, os testes de Wilcoxon e Mann-Whitney foram usados. No Grupo I, entre os estágios 1 e 2, as distâncias intertuberosidade aumentou e as distâncias intercaninos, distância anteroposterior da fissura, amplitude anterior e posterior da fissura diminuíram. A comparação entre as alterações dimensionais dos arcos dentários entre os dois centros de reabilitação apresentaram diferenças: no estágio 1, a distância intercaninos foi menor no Grupo II que no Grupo I; e no estágio 2, a amplitude anterior da fissura, a distância intercaninos e o comprimento anteroposterior da fissura foram menos no Grupo II que no Grupo I, sugerindo sobreposição dos segmentos maxilares. No Grupo II, houve maior estreitamento nas amplitudes anterior e posterior da fissura, sugerindo que a placa de Holtz no Grupo I induziu a aproximação dos segmentos maxilares de forma mais uniforme e equidistante. É importante salientar que mais estudos longitudinais precisam ser conduzidos a fim de reduzir a variabilidade de protocolos de tratamento em pacientes com fissura de lábio e palato, garantindo o melhor tratamento baseado em evidências científicas.

Page generated in 0.4065 seconds