• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 285
  • 35
  • 8
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 364
  • 364
  • 364
  • 364
  • 282
  • 279
  • 247
  • 246
  • 56
  • 54
  • 53
  • 49
  • 49
  • 46
  • 43
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

IMAGE-BASED RESPIRATORY MOTION EXTRACTION AND RESPIRATION-CORRELATED CONE BEAM CT (4D-CBCT) RECONSTRUCTION

Dhou, Salam 02 May 2013 (has links)
Accounting for respiration motion during imaging helps improve targeting precision in radiation therapy. Respiratory motion can be a major source of error in determining the position of thoracic and upper abdominal tumor targets during radiotherapy. Thus, extracting respiratory motion is a key task in radiation therapy planning. Respiration-correlated or four-dimensional CT (4DCT) imaging techniques have been recently integrated into imaging systems for verifying tumor position during treatment and managing respiration-induced tissue motion. The quality of the 4D reconstructed volumes is highly affected by the respiratory signal extracted and the phase sorting method used. This thesis is divided into two parts. In the first part, two image-based respiratory signal extraction methods are proposed and evaluated. Those methods are able to extract the respiratory signals from CBCT images without using external sources, implanted markers or even dependence on any structure in the images such as the diaphragm. The first method, called Local Intensity Feature Tracking (LIFT), extracts the respiratory signal depending on feature points extracted and tracked through the sequence of projections. The second method, called Intensity Flow Dimensionality Reduction (IFDR), detects the respiration signal by computing the optical flow motion of every pixel in each pair of adjacent projections. Then, the motion variance in the optical flow dataset is extracted using linear and non-linear dimensionality reduction techniques to represent a respiratory signal. Experiments conducted on clinical datasets showed that the respiratory signal was successfully extracted using both proposed methods and it correlates well with standard respiratory signals such as diaphragm position and the internal markers’ signal. In the second part of this thesis, 4D-CBCT reconstruction based on different phase sorting techniques is studied. The quality of the 4D reconstructed images is evaluated and compared for different phase sorting methods such as internal markers, external markers and image-based methods (LIFT and IFDR). Also, a method for generating additional projections to be used in 4D-CBCT reconstruction is proposed to reduce the artifacts that result when reconstructing from an insufficient number of projections. Experimental results showed that the feasibility of the proposed method in recovering the edges and reducing the streak artifacts.
32

Efeito do artefato de \"beam hardening\" na capacidade de identificação das alterações periodontais e peri-implantares / \"Beam Hardening\" artefact effect in identifying capacity of periodontal and peri-implant changes

Noro Filho, Gilberto Araújo 09 December 2015 (has links)
Artefatos ocorrem principalmente, próximos de estruturas de alta densidade como o metal, sendo que essa alteração pode interferir na interpretação das imagens e no diagnóstico. O intuito do presente estudo é avaliar o nível ósseo ao redor de dentes e implantes por meio de dois programas diferentes e a qualidade da imagem na presença de artefatos metálicos. Foram avaliadas imagens de arquivo obtidas através do TCFC Gendex(TM) GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). Os software utilizados foram o Xelis Dental (InfinnitHealthcare, South Korea) e o OsiriX MD (Pixmeo, Geneva, Switzerland) em cortes tomográficos transaxiais de 2 mm. Foram avaliadas 145 imagens de TCFC, sendo incluídos no estudo 35 exames (as idades variaram de 35 a 83 anos), representando um total de 30 Dentes e 30 Implantes, sendo que houve uma distribuição harmônica entre os grupos em relação ao gênero e idade. Três avaliadores treinados realizaram as observações das imagens separadamente em dois períodos distintos e a qualidade da imagem foi classificada em severa, forte, moderada e mínima. Na avaliação da qualidade de imagem os implantes apresentaram uma prevalência maior de artefatos severo e forte. No entanto, as avaliações dos implantes apresentaram uma maior consistência intra-observador, demonstrando, portanto, uma maior dificuldade na classificação dos dentes. Além disso, na avaliação conjunta de dentes e implantes a consistência global dos observadores aumentou. O software OsiriX apresentou desempenho superior nas medidas lineares dos dentes e implantes na avaliação intra-examinador. Embora nenhuma das correlações intraclasse avaliadas tenha sido excelente, a grande maioria foi satisfatória, com valores entre 0,4 e 0,7. Podemos concluir que a presença de artefatos metálicos limita a qualidade da imagem do nível ósseo ao redor dos dentes e implantes, assim como o programa OsiriX apresentou resultados nitidamente superiores na avaliação das medidas lineares. / Artifacts occur mainly near high-density structures, such as metal, this alteration may affect images interpretation and diagnosis. The aim of this study is to evaluate the bone level around teeth and implants through two different software and image quality in presence of metal artefacts. Archival images obtained were evaluated by CBCT Gendex(TM)GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). The software used was Xelis Dental (InfinnitHealthcare, South Korea) and OsiriX MD (Pixmeo, Geneva, Switzerland) in transaxial tomographic slices of 2 mm. We evaluated 145 CBCT images and included in the study 35 exams (ages ranged from 35 to 83 years-old), representing a total of 30 teeth and 30 implants, there was a harmonic distribution between groups in relation gender and age. Three trained examiners made observations of images separately in two distinct periods and the image quality evaluation was classified in severe, strong, moderate and minimal. Evaluation of implants image quality presented a higher prevalence of severe and strong artifacts. However, implants evaluation presented a higher intra-observer consistency, therefore teeth assessment presents a greater difficulty. In addition, joint assessment of teeth and implants increased global consistency of observers. OsiriX software outperformed intra-examiner linear measurements of teeth and implants. Although none of the intraclass correlations evaluated has been excellent, vast majority was satisfactory, with values between 0.4 and 0.7. We conclude that presence of metal artifacts limits the image quality of bone level around teeth and implants as well as software OsiriX presented significantly better results in the evaluation of linear measurements.
33

Avaliação da morfologia craniofaciall de indivíduos com deformidades dentofaciais de classe III por meio de tomografias computadorizadas de feixe cônico / Evaluation of the craniofacial morphology of subjects with dentofacial Class III deformities using cone beam computed tomography

Miasiro Junior, Hiroshi 03 April 2009 (has links)
A deformidade dentofacial de Classe III está associada a importantes alterações funcionais, psicológicas e estéticas. O objetivo neste trabalho foi avaliar a morfologia craniofacial de indivíduos adultos, com deformidades dentofaciais de Classe III comparando-os com um grupo de indivíduos com faces equilibradas com finalidade de diagnóstico e prognóstico ortodôntico e cirúrgico. Foram avaliados 50 indivíduos, os quais foram submetidos ao exame de tomografia computadorizada de feixe cônico (i- Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) com o propósito de avaliação e diagnóstico. A amostra foi dividida em dois grupos, sendo 25 indivíduos com equilíbrio das relações faciais e oclusão dentária excelente e 25 com maloclusão Classe III sendo que estes fazem parte da clínica de preparo ortodôntico para Cirurgia Ortognática da Faculdade de Odontologia da FOUSP. Após a obtenção dos arquivos digitais foram realizadas as reconstruções das imagens em três dimensões nos softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) e Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). Seqüencialmente foram demarcados pontos de referência anatômica e a seguir foram mensuradas grandezas lineares angulares e proporcionais que foram representadas, após avaliação estatística, por média e desvio padrão. Para determinação do erro do método foram calculadas as correlações intraclasses para avaliação da concordância e a fórmula de Dahlberg. Para comparação entre os grupos foi aplicada a Análise de Variância (ANOVA) com dois fatores, destinada a representar a oclusão e gênero. No caso de ocorrência de interação estatisticamente significativa foram realizadas comparações múltiplas de Tukey para verificar em qual dos gêneros dentro de cada grupo ocorreu diferença. O nível de significância adotado foi o de 5%. Com relação ao erro do método foi observada alta reprodutibilidade na avaliação intraoperador nos softwares Dolphin 3D® e Maxilim®. Na comparação cefalométrica 3D entre os grupos avaliados, foram observadas diferenças significativas (p<0,05), sendo que o grupo com deformidades dentofaciais Classe III demonstrou variações para o relacionamento entre altura e largura facial, associada ao aumento da porção inferior da face; rotação horária da mandíbula relacionada à maior inclinação do corpo e do ramo mandibular e pelo predomínio da altura facial anterior em relação à posterior; diminuição do comprimento e do ângulo da base craniana; compensação na altura alveolar da maxila; predominância da dimensão mandibular na configuração ânteroposterior do esqueleto facial e tendências compensatórias verticais que reduziram ao nível alveolar, os desequilíbrios esqueléticos estruturais. / Class III dentofacial deformity is associated with important functional, psychologic and aesthetics changes. The objective of this study was to evaluate the craniofacial morphology of adults, with Class III dentofacial deformity comparing them with a group of subjects with harmonious faces for diagnosis and prognosis in orthodontic and surgical cases. This study evaluated 50 subjects that were submitted to the cone beam computed tomography (i-Cat®/ Cone beam 3-D Dental Imaging System, Imaging Sciences International, Hatfield, USA) with the purpose of diagnosis. The sample was divided in two groups, one with 25 subjects with harmonious faces and excellent occlusion and another with 25 subjects with Class III malocclusion, that are in treatment in the orthodontic clinic for orthognathic surgery in the Faculty of Dentistry of University of São Paulo. After the digital archives were obtained, the 3D reconstruction of images were performed with the softwares Dolphin 3D® (Dolphin Imaging and Management Solutions, Chatsworth, CA EUA) and Maxilim® (Medicim- Medical Image Computing, Mechelen-Bélgica). After demarcation of the reference points, linear, angular and proportional measurements were made and represented in statistical analysis, by mean and standard deviation. To determine the error of method, intraclass correlations were calculated, and Dahlbergs formula was used. To compare both groups the Variance Analyses was applied (ANOVA) with two factors, representing occlusion and gender. When statistical significant differences were observed, Tukeys multiple comparison was performed to evaluate in which gender the variance happened. The level of significance adopted was 5%. The error of method showed high reproducibility for intra-operator evaluation in Dolphin 3D® and Maxilim® softwares. Cephalometric 3D evaluation of the groups, showed significant differences (p<0,05), and the group with Class III dentofacial deformity showed changes in the relationship of height and width, associated with an augmented height of the lower face; clock-wise rotation of the mandible related to an increase of the inclination of the mandible body and ramus and a greater anterior facial height in relation to the posterior facial height; decrease in the size and angulation of the cranial base; compensation in height of dentoalveolar maxilla; predominant mandibular size in anterior-posterior configuration of the facial skull and vertical dentoalveolar compensations that reduced to alveolar level the structural skeletal unbalance.
34

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico e radiografia panorâmica digital / Differentiating soft tissue calcifications in CBCT and panoramic images

Centurion, Bruna Stuchi 29 April 2011 (has links)
A maioria das calcificações em tecidos moles na região de cabeça e pescoço são achados radiográficos incidentais. Com o crescente uso da Tomografia Computadorizada de Feixe Cônico na Odontologia (TCFC) há um aumento do número desses achados, visto que o exame permite a visualização das estruturas em três dimensões. Esse estudo estabeleceu uma metodologia para identificar algumas dessas calcificações. Um observador calibrado analisou 100 exames de TCFC e as respectivas panorâmicas, quanto à presença de Ossificação do Complexo Estilo-Hióideo (OCEH), tonsilólitos e ateromas. Adicionalmente os processos estilóides foram mensurados. As correlações para as radiografias panorâmicas foram estatisticamente significante entre idade e comprimento do processo estilóide. As correlações para os exames de TCFC foram estatisticamente significantes entre idade e tonsilólitos, idade e o comprimento do processo estilóide e idade e ateromas. Houve diferença estatística significante (Wilcoxon p<0,05) entre os exames de TCFC e panorâmicas quanto à presença de tonsilólitos, presença de OCEH e para as mensurações dos processos estilóides. Foi detectada maior quantidade de calcificações em tecidos moles nos exames de TCFC. A identificação das calcificações em tecidos moles é importante no diagnóstico diferencial de muitas patologias incluindo os flebólitos. Portanto o profissional deve ficar atento a correta interpretação dessas estruturas, buscando evitar erros e omissões, para que possa oferecer ao paciente opção correta de tratamento se for necessário. / The most common soft tissue calcifications in head and neck region are incidental findings in radiographic images. The use of Cone Beam Computed Tomography in Dentistry, has increased these incidental findings mainly, because CBCT allows a third dimension view. The goal of this study was to differentiate the styloid chain ossification (SHCO), tonsilloliths and calcified atheromas. Based on a specific methodology, one calibrated observer analysed 100 panoramic and CBCT exams from the same patients regarding these alterations. Afterwards, the styloid process was measured at the same exams. The correlations tests for the panoramic exams were statistically significant between age and styloid process length. The correlations tests for CBCT exams were statistically significant between age and tonsilloliths, age and styloid process length and age and calcified atheromas. There was a difference statistically significant (Wilcoxon p<0.05) between CBCT and panoramic exams regarding: presence of tonsillolith, presence of SHCO and styloid process length. It was detected more quantity of soft tissues calcifications in CBCT exams. The identification of soft tissues calcifications is important for the differential diagnoses of many pathologies including phlebolits. Therefore the professional should be able to do a correct image interpretation in some cases in order to avoid mistakes and offer the patient a treatment if is necessary.
35

Precisão e acurácia de medidas lineares da mandíbula em imagens 3D obtidas por meio da tomografia computadorizada de feixe cônico / Accuracy and reliability of mandibular linear measurements on 3D CBCT images with different voxel sizes

Fernandes, Thais Maria Freire 29 September 2011 (has links)
Objetivo: Avaliar a precisão e a acurácia de medidas lineares da mandíbula por meio da Tomografia Computadorizada de Feixe Cônico (TCFC), alterando o valor do voxel. Material e Métodos: Dez mandíbulas foram submetidas à TCFC seguindo dois protocolos de voxel, 0,2 e 0,4 mm, do aparelho i-CAT Classic. Dez medidas lineares foram realizadas 2 vezes, por 2 examinadores independentes, previamente calibrados, nos cortes multiplanares e nas reformatações 3D no programa Dolphin®. As medidas físicas foram realizadas com um paquímetro digital diretamente nas mandíbulas. Análise de variância para medidas repetidas (ANOVA), coeficiente de correlação intraclasse e o teste de Bland-Altman foram utilizados para avaliar a precisão e a acurácia (p<0,05). Resultados: Excelente precisão intra e boa precisão interexaminadores foi encontrada para todas as variáveis, com exceção da largura interforame mentual entre os dois examinadores nas reformatação 3D. As mensurações realizadas nos cortes multiplanares apresentaram maior acurácia que as mensurações nas reformatações 3D, em relação às medidas físicas. Conclusão: As imagens nos cortes multiplanares em TCFC nos dois protocolos de voxel podem ser utilizadas com precisão e acurácia para a obtenção de medidas lineares quando comparadas com às medidas físicas. Maior cautela deve ser tomada para as reformatações 3D, pois as mensurações neste formato foram precisas, mas não acuradas para todas as variáveis. Um protocolo com menor exposição aos raios X, sem comprometer o diagnóstico, torna-se viável, pois o aumento na resolução das imagens não aumenta a precisão e acurácia na mensuração das medidas lineares avaliadas. / Objective: The purpose of this study was to determine the accuracy and reliability of mandibular linear measurements obtained from 3-dimensional cone-beam computed tomography (CBCT) scans of dry human mandibles using different voxel sizes. Methods: Ten dry human mandibles were scanned at voxel sizes of 0.2 and 0.4 mm. Craniometric anatomical landmarks were identified on the multiplanar reconstructed and on volume rendering images that were generated by the software Dolphin®, independently, by two operators twice. Subsequently, physical measurements were made using a digital caliper. Analysis of variance for repeated measures (ANOVA), Intraclass correlation (ICC) and BlandAltman were used for evaluating accuracy and reliability(p<0.05). Results: Excellent intrarater and good interobserver reliability values were found for linear measurements from CBCT images, with only one exception, interforame width, between observers in volume rendering images. Measurements performed on multiplanar reconstructed images were more accurate than the measurements in volume rendering compared to the gold standard. Conclusion: Linear measurements on multiplanar images of 0.2 and 0.4-voxel are reliable and accurate when compared with direct caliper measurements. Caution should be taken in the volume rendering measurements, because the measurements were reliable, but not accurate for all variables. A protocol with less exposure, without compromising the diagnosis becomes feasible, because an increased voxel resolution did not result in greater accuracy of the measurements and potentially provides increased patient radiation exposure.
36

Estudo de calcificações em tecidos moles em exames de tomografia computadorizada de feixe cônico utilizando diferentes softwares

Pagin, Bruna Stuchi Centurion 22 June 2015 (has links)
O uso crescente da Tomografia Computadorizada de Feixe Cônico (TCFC) na área odontológica tem permitido o aumento dos achados incidentais em exames que são realizados por outros fins. Dentre essas uma, das mais comuns e com impacto na vida dos pacientes é o ateroma calcificado das artérias carótidas (ACAC), e no seu diagnóstico diferencial existem as ossificações das cartilagens da laringe. Para correta identificação dessas calcificações são necessários conhecimentos acerca da localização anatômica, distribuição e sua morfologia, sendo que a TCFC fornece uma localização tridimensional (3D) acurada. Entretanto existem diferentes softwares de pós-processamento de imagens disponíveis no mercado, e não há na literatura estudos sobre a capacidade desses softwares para a visualização dessas estruturas. Esse estudo tem o objetivo de identificar essas calcificações supracitadas, nos softwares de visualização de TCFC, i-Cat Vision® e Invivo5®, nas reconstruções multiplanares e 3D em dois grupos diferentes, sendo um grupo de exames de indivíduos com fissuras labiopalatinas (HRAC) (50 exames de TCFC) e outro sem fissuras labiopalatinas (FOB) (100 exames de TCFC). Foram avaliados 150 exames (112 do gênero feminino e 38 do gênero masculino) de TCFC por dois observadores devidamente treinados e calibrados. Para o grupo sem fissuras labiopalatinas foi encontrada diferença estatística significante entre a idade e a quantidade de calcificações encontradas. Considerando todas as calcificações, foram encontrados 104 indivíduos com alguma calcificação, representando 69,33% da amostra, sendo que o grupo HRAC apresentou 88% e o grupo FOB 59%. Foi possível demonstrar diferença estatística significante ao se comparar a quantidade de calcificações entre os grupos avaliados. Foi assumido nesse trabalho que as reconstruções separadamente do programa Invivo5® seria a padrão- ouro, nesse momento o programa i-Cat Vision® foi considerado mais específico do que sensível. Foram identificados muito falsos positivos no programa i-Cat Vision® e menores resultados para falso-negativos. Esse trabalho não tem o propósito de identificar os ACAC nos exames de TCFC, mas incentivar e demonstrar que é possível visualizar tais calcificações e diferenciá-las umas das outra, lembrando-se da responsabilidade do dentista em prevenir um problema futuro ao paciente que pode levar a quadros de morbidade e mortalidade. / The widespread use of CBCT in Dentistry leads to an increasing of incidental findings regarding exams for different purposes. The most common incidental finding that impacts the patients quality of life is the carotid artery calcifications as well as the ossification of laryngeal cartilage which is the most common differential diagnosis for aterosclerosis. To identify this calcifications/ossification correctly it is necessary to know about its anatomic localization, distribution and morphology once that CBCT images may evidence an accurate 3D location. Therefore many different manipulations imaging software for CBCT technology is available and there is no research in the literature about the capacity of this software to visualize these calcification/ossification structures. This study aimed to identify these calcifications/ossification, in two different visualization softwares: i-Cat Vision® and Invivo5®, both in Multiplanar Reconstruction (MPR) and 3D reconstruction, in two different groups, where one was constituted of cleft lip and palate (50 CBCT exams) patients and the other by patients without cleft lip and palate (100 CBCT exams). Two calibrated and trained observers evaluated 150 CBCT exams (112 were female and 38 male). There was significantly statistical difference when comparing age and calcifications quantity for no cleft lip and palate group. When considering all calcifications in both groups, 104 patients in 150 (total number) showed some calcification/ossification, representing 69,33%. The percentage of calcification/ossification in the cleft lip and palate group were 88% whereas the other one evidenced 59%. And due to this difference, there was significantly statistical difference between these groups. Besides, the Invivo5® software was considered the gold-standard (multiplanar reconstruction and 3D reconstruction) to identify the structures previously mentioned; then i-Cat Vision® software showed more specificity than sensitivity comparing the results with the Invivo5®. Many false positives were identified in i-Cat Vision® and only some false negatives, showing again the characteristics of these softwares. This work was not intended to identify carotid artery calcifications in CBCT exams, but in fact the real purpose was to demonstrate that it is possible to identify calcifications/ossifications and differentiate one of another. It is always important to remember about the dentistry knowledge and responsibility to prevent patient coming disease that may lead to morbidity and mortality situations.
37

Avaliação da precisão da tomografia computadorizada por feixe cônico (cone beam) como método de medição do volume ósseo vestibular em implantes dentários / Evaluation of the accuracy of computed tomography cone-beam (cone beam) as a method of measuring buccal bone volume in dental implants

Shiratori, Lucy Naomi 07 December 2009 (has links)
A monitoração radiográfica das mudanças no nível ósseo fornece sinais valiosos para assegurarmos a longevidade e estética dos implantes. As radiografias periapicais e panorâmicas são importantes instrumentos que permitem esta avaliação, mas tem limitações, pois fornecem imagem bidimensional. As imagens tomográficas fornecem detalhes para estimar dimensões verticais e horizontais, possibilitam a melhor visualização de defeitos ósseos e estruturas anatômicas para o planejamento cirúrgico, além de permitir a monitoração radiográfica pós-cirúrgica ao redor dos implantes. O propósito deste trabalho foi avaliar a precisão da tomografia computadorizada por feixe cônico (TCCB) na medição do volume ósseo vestibular ao redor de implantes. Foram utilizados 8 crânios secos que receberam de 3 a 6 implantes na região da maxila anterior dependendo da disponibilidade óssea, em seguida foi realizada uma TCCB. Por meio dos cortes das imagens, as medições da parede óssea em 3 pontos do implante foram obtidas, analisadas e comparadas às realizadas no modelo do crânio em gesso, que continha implantes da mesma altura e diâmetro, nos mesmos pontos determinados, ou seja, no ápice do implante (A), a 5 mm do ápice (B) e do primeiro contato osso/implante até a plataforma do implante (C). O resultado do estudo mostrou que para os 3 pontos (A, B, C) não houve diferença estatisticamente significante das medidas realizadas no modelo real com a tomografia, ou seja, a TCCB pode ser um instrumento útil para se avaliar longitudinalmente o volume ósseo vestibular, porém, mais estudos clínicos se fazem necessários para ser utilizado na clínica diária. / Monitoring radiographic changes in bone level provides valuable signals to insure the longevity and aesthetics of implants. The panoramic and intra-oral radiographs are important devices for this assessment, but have limitations, they provide twodimensional images. The computed tomographics images provide details to estimate vertical and horizontal dimensions, allow for better visualization of bone defects and anatomical structures important in surgical planning, avoiding anatomical regions that could result in surgical injuries, and allows radiographic monitoring after surgery around implants , a factor of great importance for aesthetics and longevity of implants. The purpose of this study was to evaluate the accuracy of cone beam computed tomography (TCCB) in measuring the buccal bone volume around these implants. 8 skulls were used to install 3 to 6 implants in the anterior maxilla (canine to canine) depending on the availability of bone. These implants were installed in the skull, and then held a TCCB. Through the courts of the images, measurements of the bone wall at 3 points of the implant were obtained, analyzed and compared to those obtained in the model of the skull in plaster. Implants with the same height and diameter were used in the model and the same points determined, ie, the apex of the implant (A), 5 mm from the apex (B) and the first contact implant-bone to the plataform of the implant, were measured. (C).The results showed that for the 3 points (A, B, C) of the implants, no statistically significant difference in measurements obtained from the plaster model and computed tomographics images. Considering the results, TCCB can be a useful tool for assessing buccal bone volume along the implant, however, further studies are needed to be used in clinical practice.
38

Dosimetria em tomografia computadorizada de feixe cônico odontológica / Dental Cone Beam Computed Tomography Dosimetry

Mauro, Rodrigo Antonio Pereira 13 June 2017 (has links)
Os objetivos deste trabalho foram caracterizar os níveis de referência de radiodiagnóstico para a tomografia computadorizada de feixe cônico odontológica e as características de desempenho dos equipamentos como quilovoltaqgem de pico, rendimento, camada semirredutora, etc., com o intuito de conhecer os níveis dosimétricos em que os pacientes estão expostos, permitindo assim identificar protocolos de aquisição de imagem mais adequados, levando-se em consideração os princípios de radioproteção, e também testar a capacidade de tais equipamentos em alcançar uma imagem de qualidade. A Cone Beam Computed Tomography tem se tornado ferramenta extremamente útil na utilização em procedimentos radiológicos na área odontológica, pois, a riqueza de informações que a imagem 3D trás para o planejamento cirúrgico ou em qualquer procedimento, minimiza as possibilidades de erros, possibilita diagnósticos mais confiáveis e claros, tendo influência direta no resultado final esperado pelo paciente. Por se tratar de uma técnica de imagem que utiliza radiação ionizante, deve-se ter uma atenção criteriosa voltada para os níveis de radiação, além de implementar uma rotina de controle de qualidade. O parâmetro dosimétrico mais utilizado em tomografia computadorizada é o Computed Tomography Dose Index, porém, quando aplicado à tomografia odontológica, a geometria cônica do feixe e ainda a extensão do campo de visão tornam essa grandeza inviável e enganosa, assim, faz-se necessária a padronização de uma grandeza dosimétrica mais otimizada, para evitar a subestimação dos níveis de dose em feixes de ampla abrangência. O PKA tem sido utilizado como uma possível grandeza dosimétrica em tomografia odontológica, uma vez que em sua metodologia de medida, todo o feixe é englobado pelo medidor, não depende da distância fonte - detector, além de ser sensível aos parâmetros de exposição. Diante disso, propõe-se o PKA ser utilizado para estabelecimento dos níveis de dose de referência em diagnóstico odontológico. Os valores PKA obtidos para este estudo estão em uma faixa entre 34,6 mGy.cm^2 e 2901,6 mGy.cm^2, com valor médio de 980,7 mGy.cm^2. Os valores encontrados para os níveis de referência de radiodiagnóstico calculados a partir do 3º quartil estão divididos em três classes referentes ao tamanho do campo de visão, onde para campos pequenos, médios e grandes os valores são 1241 mGy.cm^2, 1521 mGy.cm^2 e 1408 mGy.cm^2 respectivamente, e 1446 mGy.cm^2 é o valor global independente do campo de visão. Os testes de controle de qualidade foram todos positivos, com uma atenção para o i-CAT FLX, que excedeu levemente o limite aceitável para a exatidão do kVp. Uma comparação entre CTDI100 e CTDI300, reportou que o CTDI300 é em média 49% maior em relação ao CTI100. Os níveis de referência de radiodiagnóstico são representativos dos níveis de dose otimizados, e servem como base para adequação e otimização dos parâmetros de exposição do equipamento. Os testes de controle de qualidade alertam para possíveis irregularidades no funcionamento do tomógrafo, e deve complementar obrigatoriamente a rotina dos procedimentos clínicos. / The objectives of this study are to characterize the radiodiagnostic reference levels for computed tomography of dental cones and as performance characteristics of equipment such as peak kyvoltage, yield, semi-reducing layer, etc., in order to know the levels of the values in that users are exposed, thus allowing to identify more adequate image acquisition protocols, taking in basic concepts of radioprotection, and also to test the capacity of such equipment in a quality image. The Cone Beam CT scan has become active, useful in medical, medical, dental, on the Internet, in any situation, minimizes as possibilities of errors, allows for more reliable and clear diagnoses, having a direct influence on the final result expected by the patient. Because it is an imaging technique that uses ionizing radiation, careful attention should be given to radiation levels, in addition to implementing a quality control routine. The dosimetric parameter most commonly used in computed tomography is the Computed tomography dose index, however, when applied to dental tomography, the conic geometry of the beam and still the extension of the field of view make this greatness unfeasible and deceptive, so it is done The. standardization of a more optimized dosimetric quantity, to avoid an underestimation of the dose levels in beams of wide range. The PKA has been used as a possible dosimetric magnitude in dental tomography, since in its measurement methodology, the whole beam is encompassed by the meter, it does not depend on the source - detector distance, besides being sensitive to the exposure parameters. Therefore, it is proposed that PKA be used for the establishment of reference dose levels in dental diagnosis. The PKA values obtained for this study ranged from 34.6 mGy.cm^2 to 2901.6 mGy.cm^2, with a mean value of 980.7 mGy.cm^2. The values found for the levels of radiodiagnostic reference values calculated from the 3rd quartile are divided into three classes referring to the size of the field of vision, where for small, medium and large fields are the values are 1241 mGy.cm^2, 1521 mGy.cm^2 and 1408 mGy.cm^2 respectively, and 1446 mGy.cm^2 is the global independent value of the field of view. The quality control tests were all positive, with an attention to the i-CAT FLX, which slightly exceeded the acceptable limit for kVp accuracy. A face between CTDI100 and CTDI300, reported that the CTDI300 is on average 49% higher than the CTI100. Radiodiagnostic reference levels are representative of optimized dose levels and serve as a basis for adequacy and optimization of the exposure parameters of the equipment. The quality control tests alert to possible irregularities in the operation of the tomograph, and develop properly from the clinical process.
39

Análise tridimensional das vias aéreas superiores de pacientes com fissura labiopalatina e discrepância maxilomandibular / Three-dimensional analysis of the upper airways of patients with cleft palate and maxillomandibular discrepancy

Lima, Thiago Freire 02 March 2015 (has links)
Objetivos: As fissuras labiopalatinas constituem a malformação congênita de maior prevalência na espécie humana. O fechamento cirúrgico do lábio e do palato, que visa restaurar a forma e a função, paradoxalmente impacta negativamente sobre o crescimento maxilar e, consequentemente, sobre a morfofisiologia nasal, levando à deformidades como desvio de septo e hipertrofia das conchas nasais. Estas alterações reduzem as dimensões internas da cavidade nasal e aumentam a resistência ao fluxo aéreo respiratório. Assim, foi objetivo do presente estudo avaliar tridimensionalmente o espaço aéreo faríngeo dos pacientes com fissura labiopalatina unilateral completa por meio de tomografia computadorizada de feixe cônico. Material e Métodos: Foram avaliados exames tomográficos de dois grupos de pacientes: 1) Grupo Controle (GC): 30 tomografias de pacientes sem FLP + discrepância maxilomandibular do tipo classe III de Angle, e, 2) Grupo Fissura (GF): 30 tomografias de pacientes com FLP unilateral completa + discrepância maxilomandibular do tipo classe III de Angle. Dois avaliadores treinados e calibrados avaliaram, em dois tempos distintos, as imagens por meio do software Dolphin Imaging 11.0, no qual foram obtidos valores de volume (V) faríngeo e da área seccional mínima faríngea (ASM). Os valores médios da ASM e do V, obtidos nas duas medições do avaliador 1, foram considerados para análise. A reprodutibilidade intra e interexaminador foram calculadas pelo oeficiente de Correlação Intraclasse. A significância das diferenças entre os grupos foram avaliadas pelo teste t de Student para amostras independentes. A correlação entre as variáveis foi aferida pelo Coeficiente de correlação de Pearson. Valores de p<0.05 foram considerados significantes. Resultados: Os valores médios de V (mm3) do GF (20,9±5,0) foram significantemente menores que os do GC (26,9±9,6) (p=0,004). Apesar de estatisticamente não significante, os indivíduos do GF apresentam as ASMs dimensionalmente menores (158,6±99,1) que as do GC (188,8±110,2). Constatou-se forte correlação positiva entre as variáveis ASM e V, nos grupos GC e GF (p<0.001) e forte correlação negativa entre as variáveis ASM e idade, apenas no grupo GF (p=0.017). Conclusão: A faringe do paciente com fissura labiopalatina unilateral completa com discrepância dento-esquelética classe III de Angle é volumetricamente menor que a de indivíduos sem fissura labiopalatina com o mesmo tipo de discrepância dento-esquelética. Este resultado sugere maior chance de colapsabilidade da faringe, e, consequentemente, maior risco para apneia obstrutiva do sono nesta população. / Objective: Cleft lip and palate (CLP) is the most prevalent congenital malformation in humans. Primary plastic surgeries, which main objective is to repair the anatomy and the function of the lip and palate, paradoxically, impair maxillary growth and, consequently, impact negatively on the nasal morphophysiology, leading to deformities such as septal deviation and turbinate hypertrophy. These changes reduce the internal nasal dimensions and increase the resistance to respiratory airflow. The aim of the present study was to evaluate three-dimensionally the pharyngeal airway space of individuals with complete unilateral cleft lip and palate by means of cone beam computed tomography. Materials and Methods: Two groups were evaluated: 1) Control group (CoG): 30 CT scans of individuals without CLP + Angle class III malocclusion, and 2) Cleft group (ClG): 30 CT scans of individuals with CLP + Angle class III malocclusion. Two trained and calibrated examiners assessed the images, in two different moments, by means of Dolphin Imaging 11.0 software. Mean values of pharyngeal volumes (V) and minimal cross-sectional areas (CSA) obtained by examiner 1 were considered for analysis. Intra and inter-examiner reproducibility were assessed by Intraclass correlation coeficiente test. The significance of differences between groups was evaluated by Student \"t\" test for independent samples. The correlation between variables was assessed using Pearson\'s correlation coefficient. P values <0.05 were considered significant. Results: Mean values of V (mm3) for the ClG (20,9±5,0) were significantly lower than for the CoG (26,9±9,6) (p=0,004). Although not statistically significant, individuals from the ClG presented with lower ASMs (158,6±99,1) than the CG individuals (188.8±110,2). A strong positive correlation was observed between the ASM and V variables in both groups (p <0.001) and a strong negative correlation was observed between the variables ASM and age, only for the ClG (p = 0.017). Conclusion: The pharynx of the patients with complete unilateral cleft lip and palate and with Angle Class III malocclusion is volumetrically smaller than that of individuals without cleft lip and palate and with the same type of skeletal discrepancy. This result suggests a greater chance for pharyngeal collapsibility in individuals with cleft lip and palate and, consequently, a greater risk for obstructive sleep apnea in this population.
40

Interferência dos artefatos de imagem causados por acessórios ortodônticos metálicos em sobreposições de imagens de TCFC / Influence of streaking artifacts due to metallic orthodontic accessories in CBCT 3D model superimposition

Silva, Fernando Penteado Lopes da 06 July 2012 (has links)
O objetivo deste estudo foi avaliar, de forma quantitativa e qualitativa, se artefatos de imagem causados por acessórios ortodônticos metálicos interferem em sobreposições tridimensionais (3D) de imagens de Tomografia Computadorizada de Feixe Cônico (TCFC). Dez crânios secos humanos foram submetidos a três aquisições tomográficas: sem acessórios ortodônticos (T1), com braquetes e tubos ortodônticos de aço inoxidável colados às superfícies vestibulares dos dentes superiores e inferiores (T2), e com fios ortodônticos de aço inoxidável inseridos nas canaletas dos referidos acessórios (T3). Os arquivos DICOM originais foram convertidos em arquivos de imagem Analyze, por meio do software Medsquare. O passo seguinte constituiu-se no registro rígido entre os pares de imagens T2-T1 e T3-T1, por meio do software Bioimage. Após o registro, foram então realizadas as sobreposições 3D entre os referidos pares de imagens, utilizando-se o software MeshValmet. Este software realiza uma codificação por mapas de cores, a partir das distâncias obtidas durante o processo de sobreposição. Distâncias positivas são codificadas com tonalidades de vermelho, enquanto que as negativas recebem tonalidades de azul. A ausência de deslocamento entre estruturas sobrepostas recebem o valor 0,0mmm sendo codificadas com a cor verde. As imagens referentes a T2 e T3 foram sobrepostas em relação à T1 no mesmo plano de espaço, para cada crânio da amostra. A partir das referidas sobreposições, foram calculadas as seguintes medidas: Distâncias Máxima, Mínima e Média, Distância Mean Square (MSD), Distância Root Mean Square (RMS) e Mediana. Estas quatro últimas caracterizaram-se como medidas de tendência central, e representaram a faixa de valores de maior concentração de dados. Os acessórios metálicos causaram artefatos de imagem principalmente nas imagens T2 e T3, porém os mesmos não comprometeram o processo de sobreposição das mesmas em relação à T1. As Distâncias Máximas foram comparadas à medida Diagonal (D), calculada a partir das dimensões dos acessórios ortodônticos e representativa dos mesmos (D=7,5mm). Nesta comparação, o teste t de Student não mostrou diferença significativa (p 0,05) indicando, de forma numérica, que os artefatos não se mostraram estatisticamente importantes em relação às dimensões dos corpos metálicos que os causaram. As medidas de tendência central foram então comparadas ao valor 0,0mm, o qual representa ausência total de deslocamento entre as imagens sobrepostas. Neste caso, o teste t também não evidenciou diferença significativa (p 0,05), indicando que a maior concentração de distâncias entre pontos em T2-T1 e T3-T1 localizou-se próxima ao referido valor. Somado a isso, a avaliação qualitativa propiciada pelas imagens corroborou tal constatação. Na comparação entre as medidas em T2-T1 e T3-T1, os coeficientes de Pearson mostraram alta correlação em relação às medidas de tendência central, como Distância Média (r=0.86), MSD (r=0.87), RMS (r=0.97) e Mediana (r=0.74). Mediante a avaliação quantitativa, complementada pela interpretação qualitativa dos dados, concluiu-se que os artefatos de imagem não comprometeram o procedimento de sobreposição de modelos 3D no presente estudo. / The aim of this study was to determine whether the artifacts caused by orthodontic metallic accessories interfere with the accuracy of three-dimensional (3D) Cone Beam Computed Tomography (CBCT) model superimposition. Ten dry human skulls were subjected to 3 CBCT scans: without orthodontic brackets (T1), with stainless steel brackets bonded (T2) and with orthodontic arch wires inserted into the bracket slots (T3). Individual 3D surface models were generated for the T1, T2 and T3 images, and the within-surface distances between T2-T1 and T3-T1 were computed. Superimposition error was calculated assuming CBCT image registration of T2 and T3 with respect to T1 using plain superimposition. The following measures were evaluated: Maximum, Mean and Mean Square Distance (MSD), Root MSD (RMS) and Median. The metallic accessories caused image artifacts primarily in T2 and T3 images which, however, did not compromise the 3D model superimposition. The maximum distances of artifacts image points were compared to the representative measure of orthodontic accessories (7.5mm), and Student t test showed no significant differences (p0.05) between both measures. When measures of T2-T1 and T3-T1 were compared, the Pearson coefficients showed a high correlation regarding the central tendency measures, as follows: Mean Distance (r=0.86), MSD (r=0.87), RMS (0.97) and Median (r=0.74). The statistical findings, which were complemented by qualitative image data obtained from this study, depicted that streaking artifacts did not affect the accuracy of CBCT 3D model superimposition of dry human skulls.

Page generated in 0.1155 seconds