• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 6
  • 1
  • 1
  • Tagged with
  • 23
  • 23
  • 10
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

[en] DESIGN OF HYDROMETER BASED ON A THIN-FILM RESISTIVE SENSOR FOR MEASURING / [pt] PROJETO DE HIDRÔMETRO BASEADO EM UM SENSOR RESISTIVO DE FILME FINO PARA MEDIÇÃO DE CONSUMO DE ÁGUA EM UNIDADES AUTÔNOMAS

LAIS DOS SANTOS GONCALVES 01 September 2022 (has links)
[pt] Em consequência de modificações econômicas, populacionais e nos padrões de consumo, a utilização de água doce aumentou significativamente nos últimos 100 anos. Notoriamente, a medição mostra-se primordial para estimular a conservação da água. Sendo assim, esta dissertação tem por intuito contribuir para o aprimoramento das tecnologias dos hidrômetros, mais especificamente para medição do volume de água escoado em uma tubulação de unidades autônomas em edifícios. Com isso, o presente estudo objetiva avaliar a aplicabilidade de um sensor resistivo de filme fino (bend sensor), com diferentes revestimentos e comprimentos, para implementação em sistemas de medição individualizada de água. Além disso, a motivação deste trabalho é propor um hidrômetro utilizando as válvulas de controle de fluxo que, normalmente, já estão presentes nas instalações hidráulicas condominiais, evitando, assim, a necessidade de obras maiores em prédios antigos, que possuem medição coletiva de consumo de água. Metodologicamente, apresenta-se o sistema desenvolvido para as caracterizações eletromecânica e térmica do sensor, a simulação computacional do sensor realizada por meio do software Ansys e do circuito eletrônico feita no software LTspice (marca registrada) , o treinamento de uma rede neural artificial e as estimativas de volume a partir de pulsos trapezoidais. Os resultados obtidos permitiram avaliar, levando em consideração o tipo de revestimento, que o sensor revestido com poliéster possui um melhor comportamento para o hidrômetro proposto. Além disso, esta avaliação permitiu concluir que o bend sensor demonstrou viabilidade para ser utilizado como transdutor deste medidor volumétrico, podendo ser facilmente inserido dentro de algum componente hidráulico, como uma válvula de controle de fluxo, por exemplo. / [en] As a result of economic, population, and consumption patterns changes, the use of freshwater has increased significantly in the last 100 years. Notably, measurement is essential to encourage water conservation. Therefore, this dissertation aims to contribute to the advancement of water meter technologies, specifically for measuring the volume of water drained in a pipeline of autonomous units in buildings. Thus, the present study aims to evaluate the applicability of a thin-film resistive sensor (bend sensor) with different coatings and lengths for implementation in individualized water measurement systems. In addition, the motivation of this work is to propose a volumetric meter using flow control valves that, ordinarily, are already present in the buildings hydraulic installations, thus avoiding the need for large-scale works in old buildings, which have collective measurement of water consumption. Methodologically, it is presented the system developed for the electromechanical and thermal characterization of the sensor, the computational simulation of the sensor performed using the Ansys software, and of the electronic circuit designed in LTSpice (trademark) software, the training of artificial neural network and the volume estimates from trapezoidal pulses. The results obtained allowed us to assess that, taking into account the type of coating, the sensor coated with polyester has better behavior for the proposed hydrometer. In addition, this evaluation allowed to conclude that the bend sensor demonstrated the feasibility to be used as a transducer of this volumetric meter and can be easily inserted inside a hydraulic component, as a flow control valve, for example.
22

Nous processos d'urbanització i consum d'aigua per a usos domèstics. Una exploració de relacions a l'àmbit gironí

Garcia Acosta, Xavier 16 October 2012 (has links)
This thesis aims to expand knowledge about the management of domestic water consumption. Among the various factors that influence water consumption, price and other economic variables have already been addressed by much research on this topic, obviously because of their implications for demand management. However, other factors such as the dominant urban model, the demographic structure and certain social values may also play a very important mediating role. This thesis aims to explore the factors (demographic, regional, socioeconomic, cultural, etc.) that influence domestic water consumption in two different but complementary scales: a local scale (municipalities in the Girona counties of Alt Empordà, Baix Empordà, Gironès, Pla de l’Estany and Selva) and a household scale (in suburban areas in the municipalities of Blanes, Caldes de Malavella, Lloret de Mar, Maçanet de la Selva, Santa Coloma de Farners, Sils, Tossa de Mar, Vidreres and Vilobí d’Onyar) / La present tesi té com a objectiu principal ampliar els coneixements la gestió de l’aigua per a usos domèstics. Entre els diferents factors que influeixen en el consum d’aigua, els preus i altres variables econòmiques han estat objecte de bona part de les investigacions sobre el tema. No obstant això, altres factors com, per exemple, el model d’ocupació urbana dominant, l’estructura demogràfica o certs valors socials, poden tenir també un rol molt rellevant. En aquesta tesi es proposa aprofundir sobre els factors (demogràfics, territorials, socioeconòmics, culturals, etc.) que incideixen en la demanda d’aigua per a usos domèstics, a dues escales diferents però complementàries: la municipal (municipis de les comarques gironines de l’Alt Empordà, Baix Empordà, Gironès, Pla de l’Estany i La Selva) i la llar (urbanitzacions dels municipis de Blanes, Caldes de Malavella, Lloret de Mar, Maçanet de la Selva, Santa Coloma de Farners, Sils, Tossa de Mar, Vidreres i Vilobí d’Onyar)
23

Diseño de una obra de captación : evaluación y propuesta de mejora de las obras de conducción para fines de riego en el centro poblado de hornillos, en el distrito de Colquioc, en la provincia de Bolognesi, en el departamento de Ancash

Yaco Siancas, Cesar Neerlin, Carrion Aranda, Philips Raul 29 October 2024 (has links)
Hornillos está constituido por aproximadamente 1000 habitantes y cuenta con una junta de regantes de 35 personas quienes en conjunto tienen un total de 62 hectáreas de terreno dedicados para la siembra; sin embargo, no cuentan con un adecuado sistema de captación y conducción de agua, por lo que la producción anual se ve afectada principalmente en los meses de estiaje. Por ello, se plantea como solución el diseño de una obra de captación de agua y la mejora del sistema de conducción de agua para riego, con la finalidad de disminuir las pérdidas de agua en la conducción y aumentar la oferta de agua para así tener una mayor área de cultivo. Para esto, se necesita realizar una evaluación diagnóstica para conocer la demanda de agua de la población y estudios de ingeniería que ayudarán a realizar el diseño a nivel de detalle de la obra de captación, además de evaluar el sistema de conducción existente para así plantear mejoras a los problemas de los canales. Para ello, se realizó la recolección de datos de diferentes entidades gubernamentales y mediante trabajos de campo, con la finalidad de conocer la demanda y oferta de agua de Hornillos, mediante los softwares: Cropwat, HEC – HMS, Arcgis, Hidroesta, Google Earth y hojas de cálculo. Todos los cálculos y metodologías usados, se basaron en lo descrito por: Lutz Schols, Penman Monteith – FAO, S.C.S, normativas del ANA, el MIDAGRI y el MTC. Con los resultados obtenidos se pudo realizar el diseño de la toma tirolesa y las mejoras del canal, esto mediante la metodología descrita por la PRONAR y Krochin. Finalmente se puede concluir que, con un adecuado sistema de captación de agua (toma tirolesa) y un eficiente sistema de conducción satisface a las 62 Ha de cultivo, que demandan de 0.44 m3/s contra la oferta de 1.13 m3/s agua, además se puede aumentar el área de cultivo de la manzana hasta 140 Ha en los meses de lluvia, lo que repercute de manera positiva a las actividades económicas del centro poblado de Hornillos.

Page generated in 0.0578 seconds