• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1888
  • 48
  • 45
  • 45
  • 45
  • 31
  • 24
  • 23
  • 22
  • 14
  • 12
  • 8
  • 1
  • 1
  • 1
  • Tagged with
  • 1948
  • 1948
  • 792
  • 681
  • 347
  • 219
  • 195
  • 184
  • 166
  • 152
  • 144
  • 133
  • 120
  • 116
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
311

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Honda, Cristiane Jordão de Carvalho 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.
312

Desenvolvimento e validação de método analítico empregando cromatografia gasosa ultrarrápida para quantificação de teor total de ésteres em amostras de biodiesel /

Tercini, Antonio Carlos Bergamaschi. January 2014 (has links)
Orientador: José Eduardo de Oliveira / Banca: Danilo Luiz Flumignan / Banca: Carlos Eduardo Domingues Nazario / Resumo: Com a busca por novas fontes de energia renovável, o biodiesel foi introduzido na matriz energética brasileira, e com isso a ANP assumiu a atribuição de regular e fiscalizar a qualidade do biodiesel. Quimicamente, o biodiesel é uma mistura de ésteres metílicos de ácidos graxos, derivados de óleos vegetais e gorduras animais, geralmente produzidos por uma reação de transesterificação, em que a matéria prima reage com um álcool, na presença de um catalisador. É a principal alternativa ao diesel fóssil e as principais vantagens de seu uso é o fato de que é um recurso renovável não tóxico, e que diminui as emissões de gases poluentes quando adicionado ao diesel, tornando-o importante não apenas do ponto de vista energético, mas também ambiental. A ANP estabelece 25 parâmetros que devem ser analisados para certificar a qualidade do biodiesel, e os métodos analíticos que devem ser usados para sua determinação. Dentre esses, o teor total de ésteres pode ser considerado o principal parâmetro, e os métodos oficiais de análise são por cromatografia gasosa convencional e apresentam por volta de 31 minutos de corrida cromatográfica. Este trabalho relata o uso de cromatografia gasosa ultra-rápida para determinar o teor total de ésteres do biodiesel, diminuindo o tempo de análise em 15 vezes (1,5 min). A diferença entre a CG-UR e a CG-C está no menor comprimento da coluna capilar, de 2 a 10m, diâmetro interno reduzido, entre 0,05 e 0,10mm, aquecimento resistivo da coluna, ao invés do uso do forno convencional e taxa elevada de aquecimento da coluna. Através da elaboração de uma curva analítica e posterior validação foi possível quantificar o teor total de ésteres em biodiesel de soja em um curto intervalo de tempo, com a mesma confiabilidade. / Abstract: With the search for new sources of renewable energy, biodiesel was introduced in the Brazilian energy matrix, and the ANP took the assignment to regulate and supervise the quality of biodiesel . Chemically, Biodiesel is a mixture of a fatty acids methyl esters, derived from vegetable oils and animal fats, usually produced by a transesterification reaction in which the feedstock is reacted with an alcohol in the presence of a catalyst. It is the main alternative to fossil diesel and the main advantages of its use is the fact that it is a non-toxic renewable resource, and reduces greenhouse gas emissions when added to diesel, making it important not only from the point of view of energy but also environmental . The ANP provides 25 parameters that must be analyzed to ensure the quality of biodiesel and analytical methods to be used for its determination. Among these , the total ester content can be considered the main parameter and the official methods of analysis is by conventional gas chromatography and feature around 31 minutes into the chromatographic run . This paper reports the use of ultra -fast gas chromatography (GC- UF) to determine the total ester content of biodiesel , reducing analysis time by 15 times (1.5 min). The difference between the UF with GC- GC- C is the smaller capillary column length of 2 to 10m, reduced internal diameter between 0.05 and 0.10 mm , resistive heating of the column, rather than the use of the oven conventional and high rate of heating of the column. Through the development of an analytic curve and subsequent validation was possible to quantify the total ester content in biodiesel from soybean in a short period of time, with the same reliability. / Mestre
313

Sistema de screening para detecção de furfural e hidroximetilfurfural em amostras de cachaça por espectroscopia de reflectância difusa /

Milani, Maria Izabel. January 2016 (has links)
Orientador: Helena Redigolo Pezza / Banca: Edilene Cristina Ferreira / Banca: Orlando Fatibello Filho / Resumo: Cachaça é a denominação dada à aguardente de cana - de - açúcar produzida no Brasil com teor alcóolico entre 38 - 48% (v/v) . Um dos parâmetros de qualidade determinado neste tipo de amostra é a somatória de furfural e hidroximetilfurfural, com máximo em 5 mg para cada 100 m L de etanol anidro. Essas substâncias, além de conferir sabor desagradável à bebida possuem potencial mutagênico/ carcinogênico. As metodologias de análise geralmente utilizadas para determinação destes analitos se utilizam de técnicas cromatográficas que, além do elevado custo do equipamento e de manutenção, requem operadores capacitados e utiliza m solventes orgânicos tóxicos, nocivos à saúde do operador e ao meio ambiente. Sendo assim, em sua maioria, as técnicas cromatográficas são contrárias aos princíp ios da Química Verde. Dessa maneira, n o presente trabalho foi desenvolvida uma nova metodologia para determinação de furfural e hidroximetilfurfural em amostras de cachaça que seja mais rápida, barata e ambientalmente mais amigável que as metodologias crom atográficas usualmente utilizadas, com detecção por espectroscopia de reflectância difusa . O método desenvolvido apresentou duas curvas analíticas, sendo a do furfural A R = 27,117 C 1/2 - 0,0271 com R = 0,997 e a do hidroximetilfurfural A R = 15,822 C 1/2 - 0,0263 com R = 0,998 . Os limites de quantificação obtidos para cada um dos ana litos determinados foram de 7,70 x 10 - 6 mol L - 1 para o furfural e de 1,00 x 10 - 5 mol L - 1 para o hidroximetilfurfural. Os testes para avaliação de interferência da matriz apresenta ram resultados de recuperação entre 89,5 e 108 %, co ncluindo que a matriz não influencia de maneira significativa na determinação dos analitos. A metodologia desenvolvida foi comparada com um método já descrito na literatura, os resultados obtidos foram com parados estatisticamente pelo teste... / Abstract: Cachaça is the name given to sugarcane spirits produced in Brazil with alcohol content from 38 to 48% (v/v) . One of the quality parameters analyzed is the sum of furfural and hydroxymethylfurfural, with a maximum value of 5 mg per each 100 mL of anhydrous ethanol. These two substances have a mutagenic/carcinogenic power, besides they give a bad flavor to the beverages. The methodologies usually used to determinate the anlytes a re chromatographic techniques that, besides the high cost of the equipaments and its maintenance, they need toxic organic solvents that are harmful to operators and the environment. Therefore, chromatographic techniques are mostly against Green Chemistry p rinciples. In this way, the present study aims to develop a new methodology to determinate furfural and hydroxymethylfurfural in cachaça samples that is faster, cheaper and more eco - friendly than the chromatographic methods usually used, with detection by diffuse reflectance spectroscopy. In the method here described, it was obtained two analytical curves; furfural curve is A R = 27. 117 C 1/2 - 0. 0271 with R = 0,997 and hydroxymethylfurfural curve is A R = 15. 822 C 1/2 - 0. 0263 with R = 0,998 . Limits of quanti fication for each analyte were determined as 7.70 x 10 - 6 mol L - 1 to furfural and 1.00 x 10 - 5 mol L - 1 to hydroxymethylfurfural . The test to evaluate matrix interference sho ws a recovery result between 89,5 and 108%, indicating that the matrix does not have a si gnificant interference in analytes determination. The develop methodology was compared against a methodology already described in literature; the results were compared statically by Studant's t - test, the calculated values for t - test were numerically lower then the table value, indicating that there is no significant statistic difference between values found by both methods. / Mestre
314

Avaliação da evolução e estratégias para controle da concentração do dióxido de carbono em uma sala de aula /

Odisi, Francisco, 1958-, Reinehr, Edelberto Luiz, 1957-, Noriler, Dirceu, 1978-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Química. January 2013 (has links) (PDF)
Orientador: Edelberto Luiz Reinehr. / Co-orientador: Dirceu Noriler. / Dissertação (mestrado) - Universidade Regional Blumenau, Centro de Ciências Tecnológicas, Programa de Pós-Graduação em Engenharia Química.
315

Qualidade de serviços na saúde :análise comparativa entre a prestação do serviço público e privado /

Dannenhauer, Andréia Michele, 1985-, Carvalho, Luciano Castro de, 1978-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Ciências Contábeis e Administração. January 2016 (has links) (PDF)
Orientador: Luciano Castro de Carvalho. / Dissertação (Mestrado em Administração) - Programa de Pós-Graduação em Administração, Centro de Ciências Sociais Aplicadas, Universidade Regional de Blumenau, Blumenau.
316

Estudo comparativo de metodologias de digitalização de mapas e seu controle de qualidade geométrica. / Comparative studying of map digitizing methods and the geometric quality control.

Marcelo Antonio Nero 18 December 2000 (has links)
O objetivo deste trabalho é estudar os métodos de digitalização de bases cartográficas na escala de 1:50.000, bem como analisar formas de realizar o controle de qualidade do produto final. No processo de digitalização foram empregadas as seguintes metodologias: digitalização em mesa, em tela (heads-up), semi-automática e automática. O emprego de tais metodologias de digitalização prevê a possível utilização da base cartográfica digital em um sistema de informação geográfica, necessitando assim de alguns cuidados adicionais. Em todo esse processo, deverão ser levados em conta variáveis como: tipo e qualidade do mapa original, equipamentos, programas, recursos especiais oferecidos e uma avaliação dos tempos de digitalização e edição. Também foi dada atenção ao controle de qualidade geométrica, propondo-se um roteiro para avaliar o padrão de exatidão cartográfico (PEC), seguindo as normas vigentes no país e utilizando nesse processo pontos de controle com coordenadas obtidas das folhas 1:10.000 do IGC e de levantamentos GPS. / The purpose of this work is to study digitizing methods for cartographic bases in 1:50.000 scale, as well as to analyse ways to carry out the quality control for the final products. During the digitizing process, have been the following methods employed: tablet digitizing, screen (heads-up), semi automatic and automatic raster/vector conversion. These methodologies foresees the introduction of this cartographic base in a geographic information system, which asks for some further care. All this process shall be considered variables such as: kind of map, original quality of map, equipment, programs, special resources and an evaluation of time spent in digitzing and edition. Attention has also been given to the geometric quality control by observing cartographic accuracy standard (CAS) result, based on the standards used in Brazil and, for this, taking into account control points with coordinates obtained from 1:10.000 IGC maps and GPS surveying.
317

Aplicação de câmaras de ionização especiais para controle de qualidade em mamografia / Application of special ionization chambers for quality control in mammography

Cristiane Jordão de Carvalho Honda 19 August 2015 (has links)
A mamografia é um exame realizado no mamógrafo, que utiliza raios X para obter imagens da anatomia interna da mama. Para que esta imagem seja capaz de fornecer um diagnóstico correto, é necessário que os equipamentos passem constantemente por programas de controle de qualidade para que se possa garantir que as pacientes submetidas a este exame não estejam recebendo dose além da necessária, evitando-se assim possíveis efeitos biológicos indesejados. As câmaras de ionização são detectores muito utilizados para se realizar o controle de qualidade de equipamentos que utilizam radiação, como os mamógrafos. No presente trabalho foram utilizadas quatro câmaras de ionização desenvolvidas no Laboratório de Calibração de Instrumentos do IPEN LCI/IPEN, que foram submetidas a testes de caracterização em feixes padrões de radiação X do LCI. Elas apresentaram resultados satisfatórios, dentro dos limites estabelecidos pelas normas nacionais e internacionais. Como aplicação, estas câmaras de ionização foram utilizadas para testes de controle de qualidade em quatro mamógrafos clínicos de diferentes instituições quanto à repetibilidade e linearidade da taxa de kerma no ar. Os resultados obtidos nestes testes encontram-se dentro dos limites recomendados pelas normas nacionais e internacionais. / Mammography is an examination in mammography, which uses X-rays to obtain images of the internal anatomy of the breast. To provide a correct diagnosis, it is necessary that the equipment constantly undergo quality control programs to ensure that patients submitted to this examination do not receive more than the necessary dose, thus avoiding unwanted possible biological effects. The ionization chambers are widely used detectors to perform the quality control program of equipment with radiation, as mammographers. In the present study, four different special ionization chambers, developed at the Calibration Laboratory of Instruments of IPEN - LCI / IPEN, were submitted to the characterization tests in standard X radiation beams at the LCI. The results were satisfactory, within the limits estabilished by national and international standards. As an application, the ionization chambers were used for quality control tests in four mammography clinics from different institutions, as the repeatability and linearity of the air kerma rate. The results obtained in these tests were within the limits recommended by national and international standards.
318

"Elaboração e Implementação de Testes de Controle de Qualidade em Equipamentos de Angiografia por Subtração Digital" / Elaboration and Implementation of Quality Control Tests in Digital Subtraction Angiography Equipments

Patricia Lammoglia 20 November 2001 (has links)
Foram elaborados e implementados testes de controle de qualidade em equipamentos de angiografia por subtração digital. Estes testes foram baseados em normas nacionais e internacionais e foram implementados em cinco equipamentos de três instituições diferentes. Estes testes avaliam os parâmetros de desempenho dos equipamentos e são utilizados para a determinação da taxa de kerma no ar na entrada da pele do paciente e do corpo clínico. Os testes foram realizados utilizando dispositivos, simuladores de pacientes e câmaras de ionização. Os testes convencionais e do sistema de subtração digital indicaram que os equipamentos avaliados encontravam-se em bom estado de desempenho. Os testes para verificação da taxa de kerma no ar indicaram que um dos equipamentos avaliados apresentou altas taxas de kerma no ar na entrada da pele do paciente em modo fluoroscopia. Este problema foi notificado, e as devidas providências foram imediatamente tomadas pela gerência do hospital. / Quality control tests were elaborated and implementated in digital subtraction angiography equipments. These tests were elaborated based in national and international standards, and they were implementated in five equipments of three different institutions. These tests are utilized to evaluate the performance of these equipments and to determine the patient entrance and personnel air kerma rates. The tests were performed using test tools, patient phantoms e ionization chambers. The conventional tests and the tests of the digital subtraction systems indicated that the evaluated equipments presented a good performance. The tests implementated to determine the air kerma rates presented, in one case (fluoroscopy equipment), high patient entrance skin air kerma rate. This problem was notified, and the providences were promptly taken by the hospital administration.
319

Aceite, comissionamento e controle de qualidade em radiocirurgia / Acceptance, commissioning and quality control in radiosurgery

Dalila Luzia Toreti 01 December 2009 (has links)
A Radiocirurgia Estereotática é a técnica de tratamento que usa feixes estreitos de radiação focalizados com grande exatidão em uma lesão pequena. A introdução dos colimadores micro multi-lâminas (mMLC) permite que essa técnica alcance um maior grau de conformação de dose na lesão alvo, possibilitando uma menor irradiação das estruturas críticas e dos tecidos normais. Este trabalho visa apresentar os resultados dos testes de aceite e do comissionamento de um acelerador linear Varian ® 6EX dedicado à Radiocirurgia, associado com o colimador multi-lâminas da BrainLab ® instalado no Hospital das Clínicas da Faculdade de Medicina da USP (HC-FMUSP) e estabelecer um Programa de Garantia de Qualidade que seja exequível para os serviços que pretendem implantar essa técnica especial. Os resultados dos testes de aceitação mostraram-se coerentes e satisfatórios com as especificações definidas pelo fabricante e os testes de comissionamento ficaram dentro das recomendações internacionais. Os testes e as medidas que compõem o processo de controle de qualidade devem ser específicos para cada unidade de tratamento, assim como a necessidade, a frequência e os níveis de tolerância. / Stereotactic Radiosurgery is a treatment technique that uses narrow beams of radiation focused with great accuracy in a small lesion. The introduction of micro multileaf collimators (mMLC) allows this technique to reach a higher degree of dose conformation of the target lesion allowing a smaller irradiation of critical structures and normal tissues. This paper presents the results of the acceptance tests and commissioning of a Varian ® 6EX linear accelerator dedicated to radiosurgery associated with the BrainLab ® micro multileaf collimator installed in the Hospital das Clínicas da Faculdade de Medicina da USP (HC-FMUSP) and establish feasible quality assurance program for the services that employ this special technique. The results of the acceptance tests were satisfactory and are willing with the specifications provided by the manufacturer and the commissioning tests were within the international recommendations. The tests and measures that are part of quality control process should be specific to each treatment unit, and the need, frequency and levels of tolerance.
320

Desenvolvimento de uma metodologia de calibração \"in situ \" de medidores de atividade / Development of an \"in situ\" calibration methodology to activity meters

Lilian Toshie Kuahara 28 June 2017 (has links)
O desempenho de uma prática segura e eficiente de um serviço de medicina nuclear depende, entre outros fatores, de um programa de controle de qualidade completo, principalmente em se tratando dos instrumentos medidores de atividade dos radionuclídeos, os ativímetros. Um programa de controle de qualidade completo deve incluir a calibração de todos os instrumentos de medição utilizados no procedimento. No entanto, no Brasil, a atual norma que estabelece os requisitos de proteção radiológica para serviços de medicina nuclear (SMN), não inclui, ainda, a calibração do ativímetro. Considerando que estes instrumentos, por diversas razões, são de difícil remoção para envio a um serviço de calibração, o propósito deste trabalho foi desenvolver uma metodologia de calibração de medidores de atividades que possa ser aplicada \"in situ\", para o principal radiofármaco utilizado atualmente, o 99mTc. Foram definidos os parâmetros de influência que devem ser levados em conta durante a calibração, assim como uma logística de transporte dos radiofármacos. Um programa de controle de qualidade foi aplicado aos ativímetros do Laboratório de Calibração de Instrumento (LCI). Neste trabalho foram desenvolvidas três metodologias diferentes de calibração, considerando a logística disponível e também a origem da fonte de referência. Na primeira metodologia poderá ser aplicada nos casos em que o LCI envia uma fonte de referência ao SMN. Na segunda o SMN envia uma fonte previamente medida ao LCI que determinará sua atividade real. A terceira metodologia foi aplicada para calibração dos ativímetros pertencentes ao setor de produção de radiofármacos do IPEN. Neste caso a fonte de referência foi enviada ao LCI após uma medição prévia pelo setor de produção. Foi possível aplicar as metodologias em alguns instrumentos pertencentes a clínicas e ao setor de produção. Em todos eles foram encontrados coeficientes de calibração diferentes entre si. A maior variação encontrada foi de 5%, indicando que a medição com este ativímetro está menor em 5% do que é necessário aplicar no paciente. Verificou-se que a troca de recipientes deixa um resíduo que não tem sido considerado nas medições clínicas, podendo acrescentar uma diferença de até 3% nas medições. / The performance of a safety and efficient practice of a nuclear medicine service depends, among other factors, on a complete quality control program, especially in the case of the radionuclide activity measuring instrument, the activimeter. A complete quality control program should include the calibration of all measurement instruments used in the procedure. However, in Brazil, the actual standard that establishes the requirements of radiological protection for nuclear medicine services (NMS), does not include the calibration of the activimeter. Considering that these instruments, for various reasons, are difficult to remove for sending to a Calibration Service, the purpose of this work is to develop a methodology for activimeter calibration that can be applied \"in situ\" to the most used radiopharmaceutical, 99mTc. The parameters of influence that should be taken in into account during the calibration were defined, as well as a transport logistics of the radiopharmaceuticals. A quality control program was applied to LCI activimeters. In this study, three calibration methodologies have been established, considering the available logistics and the reference source origin. The first can be applied in cases that LCI sends the reference sample to the NMS. In the second, the NMS sends an already measured sample to the LCI that will determine its real activity. The third methodology was developed to be applied to the activimeters belonging to the radiopharmaceutical sector of IPEN. In this case, the reference source was sent to the LCI after a previous measurement by the production sector. It was possible to apply the methodologies in some instruments belonging to clinics and the production sector. In all of them, different calibration coefficients were found. The largest variation found was 5%, indicating that the measurement with this activimeter is 5% lower than that required for the patient. It was found that the exchange of containers leaves a residue that has not been considered in clinical measurements, and may add a difference of up to 3% in the measurements.

Page generated in 0.1826 seconds