• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 46
  • 17
  • 5
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 79
  • 79
  • 38
  • 37
  • 35
  • 33
  • 27
  • 25
  • 24
  • 21
  • 17
  • 17
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Efeito dos novos antiagregantes plaquetários prasugrel e ticagrelor administrados upstream sobre os achados angiográficos da angioplastia primária / Effect of new antiplatelet prasugrel and ticagrelor upstream therapy, on angiographic results of primary percutaneous coronary intervention

José Ronaldo Mont\'Alverne Filho 03 August 2015 (has links)
Introdução. A dupla antiagregação plaquetária traz benefícios no tratamento do infarto agudo do miocárdio com supradesnivelamento do segmento ST (IAMSST). Há variabilidade intra e interindividual no uso do clopidogrel e isso influencia no benefício do seu uso nesse grupo de pacientes. O objetivo desta pesquisa foi avaliar os efeitos de novo antiagregantes plaquetários (prasugrel e ticagrelor) administrados na sala de emergência (\"upstream\") sobre o resultado angiográfico da angioplastia primária, levando em conta o fluxo coronariano TIMI, o blush miocárdico e a carga de trombo. Métodos. Foi realizado um ensaio clínico, randomizado, cego, com 131 pacientes admitidos com IAMSST. Todos os pacientes receberam ácido acetilsalicílico (AAS). Os pacientes foram randomizados para receber clopidogrel (n=44), prasugrel (n=41) ou ticagrelor (n=46) como dose de ataque ainda na emergência. Todos os pacientes foram submetidos a aspiração manual de trombos. Ao término do procedimento, o resultado angiográfico foi avaliado quanto ao fluxo TIMI, o blush miocárdico e a carga de trombo. Resultados. O fluxo coronariano TIMI >= 1 antes do procedimento foi observado mais frequentemente com o uso de ticagrelor (n = 10, 21,7%) do que com o clopidogrel (n = 1, 2,3%) e prasugrel (n = 5, 12,2%; p = 0,019). O fluxo TIMI coronária no fim do procedimento não diferiu significativamente entre os grupos (p = 0,101). Melhor resultado no que diz respeito ao blush miocárdico foi observada com prasugrel, que produziu um grau de blush III em 85,4% (n = 35) dos pacientes, em comparação com o clopidogrel (54,5%; n = 24) e ticagrelor (67,4%; n = 31; p = 0,025). A carga de trombo pré-procedimento foi maior no grupo de clopidogrel, em que 97,7% (n = 43) dos casos denotaram carga de trombo grau 4/5, enquanto 87,8% (n = 36) do grupo prasugrel tiveram respostas semelhantes, e 80,4% (n = 37) foram observadas no grupo ticagrelor (p = 0,03). Conclusão. Os novos antiagregantes plaquetários ticagrelor e prasugrel parecem exercer efeito sobre o resultado angiográfico dos pacientes submetidos a angioplastia primária. O uso do ticagrelor propiciou menor carga de trombo e um fluxo TIMI melhor no pré-procedimento e o uso do prasugrel ensejou melhor perfusão miocárdica analisada pelo blush miocárdico. Não houve diferença no fluxo angiográfico TIMI pós procedimento / Introduction. Dual antiplatelet therapy has benefits in the treatment of acute myocardial infarction with ST-segment elevation (STEMI). There is variability intra and inter individual in the use of clopidogrel and this influences the benefit of its use in this group of patients. The objective of this research was to evaluate the angiographic results of Upstream Clopidogrel, Prasugrel, or Ticagrelor For Patients Treated With Primary Angioplasty. Methods. A clinical trial was conducted, randomized, double blind, with 131 patients admitted with STEMI. All patients received acetylsalicylic acid (ASA). Patients were randomized to receive clopidogrel (n = 44), prasugrel (n = 41) or ticagrelor (n = 46) as loading dose even in emergency. All patients were submitted to manual thrombus aspiration. At the end of the procedure, the angiographic result was evaluated for TIMI flow, myocardial blush and thrombus burden. Results. A coronary TIMI flow >= 1 before the percutaneous procedure was observed more frequently with the use of ticagrelor (n=10, 21.7%) than with clopidogrel (n=1, 2.3%) and prasugrel (n=5, 12.2%; p=0.019). The coronary TIMI flow at the end of the procedure did not significantly differ between the groups (p=0.101). A better result with respect to myocardial blush was observed with prasugrel, which yielded a blush grade of III in 85.4% (n=35) of patients, compared with clopidogrel (54.5%; n=24) and ticagrelor (67.4%; n=31; p=0.025). The pre-procedural thrombus burden was found to be of a higher grade in the clopidogrel group, in which 97.7% (n=43) of the cases exhibited thrombus burdens grade 4/5, whereas 87.8% (n=36) of the prasugrel group had similar responses, and 80.4% (n=37) were observed in the ticagrelor group (p=0.03). Conclusions. The novel antiplatelet agents represented by ticagrelor and prasugrel appear to have effect on the angiographic outcome of patients undergoing primary angioplasty. The use of ticagrelor led to a smaller thrombus burden and better TIMI flow at the beginning of the procedure and the use of prasugrel produced a better myocardial perfusion analyzed by myocardial blush. There was no difference in post angioplasty TIMI flow
42

Noninvasive evaluation of the effects of coronary artery bypass grafting on myocardial function /

Hedman, Anders, January 2006 (has links)
Diss. (sammanfattning) Stockholm : Karolinska institutet, 2006. / Härtill 4 uppsatser.
43

Contrast-induced nephropathy in coronary angiography patients when using Ioversol and Iomeprol : a meta-analysis

Chipere, Tawanda Alfred Gilbert 06 1900 (has links)
Ioversol and Iomeprol are radiological contrast media commonly used interchangeably in many South African imaging facilities for coronary angiography. Despite differences in chemical composition, they are presumed to have similar renal safety profiles. However, no studies directly compare the renal safety of these two contrast media for coronary angiography in a predominantly healthy population. A systematic review was performed to establish which contrast medium is safer. Articles were sourced from Medline, CINAHL, Scopus, Science Direct, and PubMed Clinical Queries databases. Eligible studies were peer-reviewed articles of coronary angiography examinations carried out on a healthy adult population, where Ioversol or Iomeprol or both were administered, with contrast-induced nephropathy as an end-point. Six articles with a total population of 2431 patients were selected. The Cochrane Risk of Bias Tool was used in evaluating included articles. Pooling studies using the random effects model did not show a statistically significant reduction in contrast-induced nephropathy when Iomeprol was administered (Risk ratio 1.14, 95% confidence interval 0.797-1.643, p = 0.466). Moderate heterogeneity (I2=54.21%) across the studies was observed. Study limitations included potential bias during data extraction because this was performed by a single reviewer, and language restrictions to include only English titles. Iomeprol may be better for use in the clinical setting because of more a predictable renal safety profile. / Health Studies / M. P. H. (Health Studies)
44

Estudo dos determinantes de doença arterial coronária grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de estenose de artéria rena / Determinants of severe coronary artery disease in hypertensive patients with indications of renal angiography for suspected renal artery stenosis

Thiago Andrade de Macêdo 23 April 2012 (has links)
INTRODUÇÃO: Em pacientes hipertensos com suspeita de doença arterial coronária (DAC), indicações para a realização de arteriografia renal no mesmo procedimento da cinecoronariografia estão bem estabelecidas. Entretanto, em hipertensos com suspeita de estenose de artéria renal (EAR) com indicação de arteriografia renal, não estão bem definidos os determinantes da presença de DAC grave. OBJETIVOS: Avaliar a prevalência e os determinantes de DAC grave em pacientes hipertensos com indicação de arteriografia renal por suspeita de EAR. METODOLOGIA: Oitenta e dois pacientes com suspeita clínica de EAR foram submetidos à cinecoronariografia e arteriografia renal no mesmo procedimento. Lesão arterial significativa em artérias renal e/ou coronária foi definida por obstrução luminal maior ou igual a 70%. RESULTADOS: Obstrução luminal significativa, tanto em artéria coronária quanto em renal, foi encontrada em 39% dos pacientes. Os pacientes com DAC grave apresentaram idade mais avançada (63±12 vs. 56±13 anos; p=0,03), maior prevalência de angina (41 vs. 16%; p=0,013), maior diâmetro do átrio esquerdo (44,7 vs. 40,6mm; p=0,005) e maior velocidade de onda de pulso (12,6 vs. 10,7 m/s, p=0,02), comparados com os pacientes sem DAC grave. A presença de EAR significativa esteve associada a uma maior prevalência de DAC grave comparada a pacientes sem a lesão (66% vs. 22%; p<0,001). A análise multivariada demonstrou que EAR70% esteve associada com DAC grave de maneira independente (OR: 11,48; 95%CI 3,2-40,2; p<0,001), mesmo em pacientes sem angina (OR: 13,48; 95%CI 2,6-12,1; p<0,001). CONCLUSÃO: Há elevada prevalência de doença coronária grave em pacientes hipertensos com estenose de artéria renal significativa. A presença de estenose maior ou igual a 70%, verificada em arteriografia renal, é preditor forte e independente para a presença de DAC grave, mesmo na ausência de angina / INTRODUCTION: In patients with suspected coronary artery disease (CAD), indications for performing coronary and renal angiography at the same setting are well established. However, in hypertensive patients with suspected renal artery stenosis (RAS) with indication for renal angiography, it is not well defined the determinants of the presence of severe CAD. OBJECTIVES: We aimed to evaluate the prevalence and determinants of severe CAD in hypertensive patients referred to renal angiography for the diagnosis of RAS. METHODS: Eighty-two consecutive patients with high clinical risk for RAS systematically underwent renal angiography and coronary angiography at the same procedure. Significant RAS and CAD were defined as arterial luminal obstruction 70%. RESULTS: Either significant RAS or significant CAD were present in 32/82 patients (39%). Patients with severe CAD were older (63±12 vs. 56±13 years, p=0.03), had more angina (41 vs. 16%; p=0.013), higher left atrial diameter (44.7 vs. 40,6mm; p=0.005), and higher pulse wave velocity (12.6 vs. 10.7 m/s); p=0.02) compared to patients without significant CAD. Significant RAS was associated with an increased prevalence of severe CAD compared to patients without the lesion (66% vs. 22%, respectively; p<0.001). Binary logistic regression analysis showed that RAS 70% was independently associated with severe CAD (OR: 11.48; 95%CI 3.2-40.2; p<0.001), even in patients without angina (OR: 13.48; 95%CI 2.6-12.1; p<0.001). CONCLUSION: The prevalence of severe CAD in hypertensive patients with significant RAS is high. The presence of RAS 70%, diagnosed by renal angiography, is a strong and useful predictor to identify severe CAD, independently of the presence of angina
45

Comparação entre tomografia das artérias coronárias e ultrassonografia intracoronária na avaliação de pacientes submetidos a implante de suporte vascular bioabsorvível polimérico radiolucente / Comparison between computed tomography coronary angiography and intravascular ultrasound in measuring coronary segments of patients treated with a radiolucent bioresorbable vascular scaffold

Jorge Augusto Nunes Guimarães 22 April 2014 (has links)
Introdução: A tomografia das artérias coronárias (ANGIO-TC) tem o potencial de medir as dimensões dos vasos e pode ser opção, aos métodos invasivos, para análises quantitativas em intervenções coronárias com suportes vasculares bioabsorvíveis (SVB) poliméricos radiolucentes. Objetivos: Medidas quantitativas pela ANGIO-TC do lúmen de segmentos coronários de pacientes submetidos a implante de um SVB com eluição de novolimus (DESolve®) foram comparadas às do ultrassom intracoronário (USIC). Os objetivos primários foram a comparação da área mínima e do volume do lúmen do SVB. Outros objetivos incluíram medidas nas margens do dispositivo, de referências do vaso e dos percentuais de estenose do SVB. A precisão de identificação do local de menor dimensão foi estimada pela distância entre este e a borda proximal do SVB. Método: Vinte e um pacientes submetidos a implante de um SVB DESolve e que foram reestudados após 6 meses com cinecoronariografia e USIC realizaram, também, ANGIO-TC. Sem conhecimento dos valores um do outro, um operador, em cada método, efetuou as medidas de volume, área e diâmetro mínimos do lúmen do SVB, de áreas e diâmetros mínimos do lúmen nas margens proximal e distal do SVB, de diâmetros e áreas de referência luminais e dos percentuais de estenose de diâmetros e áreas do SVB. Diferenças entre as médias foram significativas quando testes resultaram o valor de p< 0,05. Coeficientes de correlação foram calculados e a concordância foi analisada pelo método de Bland-Altman. Resultados: Os métodos não se mostraram correlacionados ao medirem área mínima do lúmen do SVB e a ANGIO-TC subestimou significativamente os valores em relação ao USIC (diferença de médias= -1,27 mm2; p= 0,004). As medidas do volume do lúmen do SVB mostraram correlação (r= 0,58; p= 0,006) e foram equivalentes (diferença de mediana= 5,4 mm3; p= 0,14). Em ambas, houve ampla variabilidade entre as medidas (variação percentual do erro de 128% para a área e de 119% para o volume). Os métodos mostraram correlações significativas para todas as demais variáveis. As médias das medidas de diâmetros, pela ANGIO-TC, não mostraram diferenças significativas em relação ao USIC. A ANGIO-TC subestimou significativamente as medidas da área mínima do lúmen no segmento distal ao SVB (diferença= -1,09 mm2; p = 0,017) e da área de referência dos vasos (diferença = -1,34 mm2; p = 0,008). Apesar do viés mínimo, os métodos mostraram ampla variação ao identificar o ponto de menor dimensão do SVB (erro percentual = 186%). A ANGIO-TC, assim como o USIC, não identificou casos de reestenose. Os métodos mostraram melhor nível de concordância ao medirem diâmetros e maiores discrepâncias ao estimarem percentuais de estenose. Conclusões: Em segmentos coronários com SVB polimérico, a ANGIOTC não obteve correlação e subestimou a área mínima do lúmen em relação ao USIC. Quantificações do volume do lúmen foram equivalentes e correlacionadas. Independentemente do nível de correlação, o padrão de concordância das medidas evidenciou um nível de acurácia insatisfatório para a ANGIO-TC substituir o USIC para quantificações de lumens em estudos com SVB radiolucentes, embora permaneça útil para análises visuais na prática clínica. / Computed tomography coronary angiography (CTA) is able to quantify vessel dimensions and might potentially be an alternative to substitute invasive methods for quantitative analysis in percutaneous coronary interventions with bioresorbable vascular scaffolds (BVS). This study compared quantitative measurements derived from CTA images to intravascular ultrasound (IVUS) in coronary segments implanted with radiolucent DESolve(TM) novolimuseluting BVS. Primary objectives were comparisons of BVS minimal luminal area and luminal volume in BVS. Secondary objectives included comparisons of minimal luminal areas and diameters in proximal and distal segments to the BVS, luminal vessel reference areas and diameters and BVS percent area and diameter stenosis. Precision of identifying BVS luminal minimal area were assessed by measuring distance from this point to proximal BVS border. Twenty-one patients underwent both CTA and IVUS, six months after BVS deployment. Each method was performed by an experienced operator, blinded to other\'s quantifications. Correlation coefficients were calculated and mean differences with 95% limits of agreement were assessed by Bland-Altman analysis. A p-value less than 0.05 were considered statistically significant. CTA did not show correlation to IVUS and significantly underestimated minimal luminal area in BVS (mean differences = -1.27 mm2; p = 0.004). Quantitative measurements of luminal volume in BVS were equivalent (median difference = 5.4 mm3; p = 0.14) and showed modest correlation (r= 0.58; p= 0.006). Both variables showed wide limits of agreement (percent error = 128% in minimal luminal area and 119% in luminal volume). Correlations were significant in all other variables. Both methods did not show significant differences quantifying all-segment diameters, and percent area and diameter stenosis. CTA significantly underestimated measurements of minimal luminal area in distal segment after BVS (mean difference = -1,09 mm2; p = 0,017) and luminal reference area (mean difference = -1,34 mm2; p = 0,008). CTA and IVUS showed nonsignificant bias to identify BVS luminal minimal area, but very wide limits of agreement (percent error= 186%). Both methods agreed in showing no cases of binary restenosis. Regardless of correlations or mean differences, all measures showed high variability, caracterized by wide limits of agreement. The least variations resulted from diameter quantifications, whereas estimated percent stenosis presented more disparities. These discrepancies between both methods showed that CTA analysis is still not fully developed to replace IVUS in the assessment of quantitative measurements in vessels treated with BVS. It remains, however, clinically useful for visual qualitative analysis.
46

Avaliação tardia dos stents liberadores de Biolimus A9® pela tomografia de coerência óptica: análise da cobertura tecidual e da aposição das hastes / Long-term follow-up Biolimus A9TM stents with optical coherence tomography: strut apposition and tissue coverage analysis

Rodolfo Staico 04 July 2011 (has links)
Introdução: Os stents farmacológicos (SF) de primeira geração surgiram com o intuito de reduzir as taxas de reestenose intra-stent e de revascularização da lesão-alvo, sendo mais eficazes quando comparados aos stents não-farmacológicos (SNF), porém com aumento de risco de trombose do stent (TS) muito tardia. A cobertura tecidual incompleta e a má aposição tardia das hastes dos stents podem estar vinculadas à TS. O SF de segunda geração BioMatrix®, que utiliza um polímero bioabsorvível, surgiu na expectativa de redução da TS. Devido à alta acurácia e reprodutibilidade e à análise precisa da cobertura tecidual e da aposição das hastes dos stents, a tomografia de coerência óptica (TCO) vem se tornando um método útil na análise desses aspectos. O objetivo desse estudo foi avaliar a cobertura tecidual e a aposição das hastes do SF BioMatrix® após longo período do implante. Métodos: Vinte pacientes submetidos ao implante do SF BioMatrix® (n = 15) ou do SNF S-Stent® (n = 5) foram acompanhados por um período mínimo de cinco anos e avaliados por meio da angiografia coronária quantitativa (ACQ), da ultrassonografia intracoronária (USIC) e da TCO. Para a análise estatística, foram utilizados os programas SPSS® versão 16.0 e SAS versão 9.2. O valor de p < 0,05 era considerado estatisticamente significante. As variáveis categóricas foram expressas em números absolutos e porcentuais e comparadas pelo teste exato de Fisher. As variáveis contínuas foram expressas em média e desvio padrão e/ou mediana e intervalo interquartílico e foram comparadas pelo teste não paramétrico de Mann-Whitney. Resultados: A ACQ demonstrou diferença, porém não significativa na perda tardia da luz entre o SF BioMatrix® e o S-Stent® [0,40 (0,21; 0,77) mm vs 0,68 (0,66; 0,82) mm, p = 0,205]. Os pacientes tratados com o SF BioMatrix® apresentaram porcentual de obstrução do stent significativamente menor quando comparados àqueles que receberam o S-Stent® [5,6 (4,4; 9,7)% vs 28,6 (24,7; 29,0)%, p =0,001]. A análise da TCO demonstrou 126 (8,7%) hastes não cobertas nos stents BioMatrix® e 23 (4,0%) nos S-Stents® (p = 0,297), estando a maioria delas bem apostas (117/126 e 21/23, respectivamente, p = 0,292). Apenas nove (0,6%) hastes nos SF e duas (0,4%) hastes nos SNF estavam simultaneamente sem cobertura tecidual e mal apostas (p = 0,924). No grupo BioMatrix®, apenas 1 (11,1%) paciente teve todas as hastes cobertas. Já no grupo S-Stent, 66,7% dos pacientes (2/3) apresentaram cobertura completa das hastes (p = 0,127). Conclusões: A avaliação tardia do SF BioMatrix® pela TCO mostrou cobertura tecidual e aposição em quase a totalidade de suas hastes, de maneira similar àquela encontrada nos SNF S-Stents®. / Introduction: First generation drug-eluting stents (DES) have emerged as a strategy to prevent in-stent restenosis and the need of target-vessel revascularization when compared to bare metal stents (BMS); but at the expense of a higher risk of very late stent thrombosis (ST). Uncovered and malapposed struts may be associated with both late and very late ST. It has been postulated that the second generation DES, the biolimus-eluting stent BioMatrixTM with biodegradable polymer, may reduce the incidence of ST. Given its high accuracy and reproducibility with precise analysis of the complete strut apposition and strut coverage, the optic coherence tomography (OCT) has been extensively used for stent analysis. The aim of this study was to assess the struts coverage and apposition of DES BioMatrixTM in a long-term follow up. Methods: Twenty patients undergoing a BioMatrixTM (n = 15) or BMS S-StentTM (n = 5) implantation were followed up for a period of at least five years and evaluated by means of OCT, quantitative coronary angiography (QCA) and intravascular ultrasound (IVUS). All statistical analyses were performed using SPSSTM (v.16.0) and SAS (v.9.2) software. Statistical significance was considered at p values < 0.05. Categorical variables were expressed as counts and percentages, and continuous variables as mean SD and/or median and interquartile range. For per-patient level comparison, the difference between two stent types was evaluated by nonparametric Mann-Whitney U test while categorical variables were evaluated by the Fisher exact test. Results: QCA analysis showed no differences in the occurrence of intrastent late loss between the groups [0.40 (0.21; 0.77) mm vs 0.68 (0.66; 0.82) mm, p = 0.205 for BioMatrixTM and S-StentsTM, respectively]. The vessel, stent and lumen volumes assessed by IVUS after the procedure and 5 years later were similar between the two groups. Patients treated with BioMatrixTM had significantly less stent obstruction percentage when compared to those treated with S-StentTM [5.6 (4.4; 9.7)% vs 28.6 (24.7; 29.0)%, p = 0.001]. OCT analysis demonstrated 126 (8.7%) uncovered struts in the BioMatrixTM group compared to 23 (4.0%) in the S-StentsTM group (p = 0.297), being the majority of them well apposed (117/126 and 21/23, respectively, p = 0.292). Only 9 (0.6%) struts in the DES and 2 (0.4%) struts in the BMS groups were imultaneously uncovered and malapposed (p = 0.924). Among the BioMatrixTM patients, 55.6% (5/9) had more than 95% of covered struts and in only 1 (11.1%) patient all struts were covered. On the other hand, among the S-StentTM patients, 66.7% (2/3) had complete covered struts (p = 0.127). Conclusion: Long term assessment of DES BioMatrixTM by OCT showed tissue coverage and apposition in almost all struts, similary to those found in the BMS S-StentsTM.
47

Remodelamento tardio da artéria torácica interna bilateral na revascularização do miocárdio: Influência do leito coronariano esquerdo / Late remodeling of bilateral internal thoracic artery in coronary artery bypass graft surgery: influence of left coronary bed

Bruno da Costa Rocha 20 February 2006 (has links)
O enxerto de artéria torácica interna tem demonstrado capacidade de remodelamento devido a interação com o leito arterial coronariano. O objetivo deste estudo foi analisar a influência dos fatores clínicos e angiográficos no remodelamento dos enxertos, definido como variação no calibre vascular. Casuística e métodos: No período entre 1983 e 1999, 356 pacientes realizaram cirurgia de revascularização do miocárdio utilizando a artéria torácica interna esquerda para o ramo interventricular anterior e a artéria torácica interna direita para um ramo da circunflexa. Trinta e dois pacientes foram submetidos a cineangiocoronariografia pós-operatória, a qual foi posteriormente analisada com o aplicativo CASS II®. Este estudo observacional apresentou acompanhamento médio de 42 meses(6-204 meses). As variáveis angiográficas analisadas foram os diâmetros proximal e distal dos enxertos arteriais (variável dependente), área coronariana, pontuação de fluxo TIMI, diâmetro de estenose proximal, fluxo dominante distal e ramos patentes. Fatores de risco cardiovascular também foram incluídos. Resultados: O modelo de regressão linear múltiplo demonstrou um R2ajustado=0,69 (p=0,0001) para o modelo a direita e R2ajustado=0,46 (p=0,002) para a esquerda. Os enxertos apresentaram diâmetros proximal e distal de 2,67mm ±0,085 e 2,232mm ±0,085 à esquerda; 2,458mm ±0,088 e 2,010mm ± 0,091 (média±EP) à direita, respectivamente (p>0,05). Nenhuma variável clínica obteve correlação significante estatisticamente. A área coronariana apresentou coeficiente de beta=0,42 (0,14-0,6/IC-95%) e diâmetro de estenose proximal de 0,55 (0,40-0,65/IC-95%) para o remodelamento do lado direito. A área coronariana demonstrou coeficiente de beta=0,54 (0,3- 0,68/IC-95%) para o remodelamento do lado esquerdo. Conclusões: A artéria torácica interna não demonstrou diferença de calibre em relação a lateralidade (esquerda vs direita). O diâmetro de estenose proximal da artéria coronária revascularizada demonstrou correlação positiva com o remodelamento dos enxertos do lado direito. A área da artéria coronária revascularizada foi a única variável de influência para o remodelamento bilateral dos enxertos / Internal thoracic artery grafts has demonstrated capacity for remodeling due to interaction with the coronary artery bed. The goal was to analysis the influence of clinical and angiographic factors in this remodeling as defined as grafts caliber variation. Methods: In a period from 1983 to 1999, 356 patients underwent to coronary artery bypass surgery using the left internal thoracic artery anastomosed to interventricular anterior branch and the right internal thoracic artery to circumflex branches. Thirty two patients were submitted to postoperative coronary angiography which was further analysed by CASS II® software. The mean follow-up of this observational study was 42 months(6- 204 months). Angiographic variables analyzed was proximal and distal diameters of arterial grafts(dependent variable), coronary area, TIMI flow grade, proximal stenosis diameter, dominant distal flow and patent branches. Cardiovascular risk factors were included indeed. Results: The multiple regression model demonstrated R2adjusted=0.69 (p=0.0001) for right side and R2adjusted=0.46 (p=0.002) for left side. The grafts presented proximal and distal diameters of 2.67mm ±0.085 and 2.232mm ±0.085 from left side; 2.458mm ±0.088 and 2.010mm ±0.091 (mean±SE) from right side respectively (p > 0,05). None of the clinical variables had statistical significant correlation. The coronary area presented as a beta coefficient=0.42 (0.14-0.6/CI-95%) and proximal stenosis diameter of 0.55 (0.40-0.65/CI-95%) for right side remodeling. The coronary area shown a beta coefficient=0.54 (0.3- 0.68/CI-95%) for left side remodeling. Conclusions: The internal thoracic artery did not demonstrate difference in caliber about its laterality (left vs right). The proximal stenosis degree of the bypassed coronary artery demonstrated positive correlation with remodeling for the right side grafts. Bilateral grafts remodeling was only explained by positive correlation with the bypassed coronary area
48

Análise do grau de lesão obstrutiva coronária e sua correspondente parede miocárdica como fatores preditivos de perviedade e remodelamento da artéria radial na revascularização do miocárdio / Analysis of coronary obstruction and irrigated myocardial wall as predictive factors for patency and remodeling of radial artery grafts in coronary artery bypass surgery

Luciano Jannuzzi Carneiro 17 February 2009 (has links)
A artéria radial (AR) constitui valiosa opção de enxerto na revascularização do miocárdio (RM), desde a retomada de seu uso, nos anos 1990. O objetivo deste estudo foi avaliar perviedade e remodelamento dos enxertos de AR e sua relação com lesão obstrutiva pré-operatória e parede miocárdica revascularizada, observando-se também os enxertos de artéria torácica interna (ATI). CASUÍSTICA E MÉTODO: Entre 1994 e 2007, 3.964 pacientes foram operados com uso da AR, no InCor/HCFMUSP. Foram selecionados os reestudos angiográficos (12 meses) de 100 pacientes, sendo 11 deles reestudados em duas épocas diferentes. Em 92 pacientes foi utilizada a ATI. Foram determinados os diâmetros médios de AR e ATI, através do software CASS-II®. RESULTADOS: O tempo médio de reestudo foi de 70,53 ±33,18 meses. Em 82 casos (82,0%), a AR revascularizou uma única coronária, mais freqüentemente (50,83%) os ramos marginal esquerdo (ME) ou ventricular posterior (VP/CX). As obstruções pré-operatórias entre 90 e 99% foram as mais prevalentes (39,0%). A perviedade observada foi de 80 casos para AR (80,0%) e 80 para ATIE (86,96%). Houve correlação entre as maiores obstruções pré-operatórias e maior perviedade da AR (p=0,024). Os diâmetros médios dos enxertos foram de 2,302mm ±0,479 (AR) e 2,262mm ±0,409 (ATI). Observaram-se AR maiores do que a média (>2,30mm) nas obstruções pré-operatórias de 100%, em comparação com as demais (p=0,017). As AR que revascularizaram a parede lateral apresentaram os maiores diâmetros, em comparação às demais (p=0,04). Nos 11 pacientes com 2 reestudos, os diâmetros médios das AR foram de: 2,482mm ±0,424 (primeiro reestudo) e 2,599mm ±0,532 (segundo reestudo)(p=n/s). Para as ATIE, observaram-se: 2,308mm ±0,459 (primeiro reestudo) e 2,326mm ±0,531 (segundo reestudo) (p=n/s). No segundo reestudo, observou-se maior número de AR com diâmetros maiores, relacionados às obstruções entre 90-100% (p=0,013). A parede miocárdica revascularizada não interferiu nos diâmetros dos enxertos. CONCLUSÕES: A obstrução pré-operatória interfere na perviedade e nos diâmetros dos enxertos de AR, especialmente nas obstruções de 90% ou mais. A parede miocárdica revascularizada não interfere na perviedade da AR, porém interfere nos diâmetros dos enxertos. Foi observado remodelamento dos enxertos de AR, estando as obstruções mais graves relacionadas aos maiores aumentos de diâmetros dos enxertos comportamento semelhante às ATI. / The radial artery (RA) is an invaluable option for coronary artery bypass grafting (CABG), since its re-introduction in the late 1990 s.The objective of this study was to assess patency and remodeling of RA grafts regarding the interference of pre-operative coronary obstruction and grafted myocardial wall, also observing the internal thoracic artery grafts (ITA). METHODS: Between 1994 and 2007, 3,964 patients were operated with RA grafts, at Heart Institute, University of São Paulo, Brazil. Post-operative coronary angiographies (12 months)of 100 patients were obtained, including 11 patients with two post-op exams, at different periods. In 92 patients the ITA was also used.The grafts medium diameters were obtained using the CASS-II® software. RESULTS: Mean time of post-op angiography was 70,53 ±33,18 months. In 82 cases (82,0%) the RA grafted a single coronary, more frequently (50,83%) the left marginal (LM) or posterior ventricular (PV) branches. Pre-op obstructions between 90 and 99% were more prevalent (39,0%). Patency was of 80 cases for the RA (80,0%) and 80 cases for the ATI grafts (86,96%). There was a correlation between more severe pre-op obstructions and greater patency of the RA grafts (p=0,024). The mean diameters were 2,302mm ±0,479 (RA) and 2,262mm ±0,409 (ITA). RA diameters were above the mean value (>2,30mm) in pre-op obstructions of 100%, compared to the rest (p=0,017). The RA grafting the lateral wall showed the larger diameters, compared to the rest (p=0,04). For the 11 patients with 2 post-op angiographies, mean diameters of RA grafts were: 2,482mm ±0,424 (first) and 2,599mm ±0,532 (second)(p=n/s). For ITA grafts, mean diameters were: 2,308mm ±0,459 (first) and 2,326mm ±0,531 (second)(p=n/s). For the second angiographies, RA grafts exhibited larger diameters, related to pre-op obstructions between 90 and 100% (p=0,013). The grafted myocardial wall showed no interference with graft diameter. CONCLUSIONS: Pre-op coronary obstruction interferes in patency and diameters of RA grafts, more evidently for obstructions of 90% or greater. The grafted myocardial wall does not interfere with RA patency, although it does interfere with graft diameter. Remodeling was observed in RA grafts, correlating greater pre-op coronary obstructions and more evident increase in graft diameter similarly to the ITA grafts.
49

Análise quantitativa da doença arterial coronariana obstrutiva por tomografia computadorizada de 64 detectores e pela cinecoronariografia e sua correlação com o equivalente isquêmico detectado pela cintilografia de perfusão miocárdica = Quantitative coronary artery stenosis assessment by multidetector CT and invasive coronary angiography for identifying patients with myocardial perfusion abnormalities / Quantitative coronary artery stenosis assessment by multidetector CT and invasive coronary angiography for identifying patients with myocardial perfusion abnormalities

Godoy, Gustavo Khattar de, 1978- 25 August 2018 (has links)
Orientadores: Celso Darío Ramos, João Augusto Lima / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-25T22:27:02Z (GMT). No. of bitstreams: 1 Godoy_GustavoKhattarde_D.pdf: 2269934 bytes, checksum: b16ad3f63241f0e2537f807b8c45d497 (MD5) Previous issue date: 2014 / Resumo: Este trabalho consiste na comparação de diferentes métodos de imagem utilizados na prática clínica para a detecção da doença coronariana isquêmica, umas das maiores causas de mortalidade nos países desenvolvidos, utilizando como base o estudo multicêntrico Internacional, Core 64. Através de uma análise retrospectiva foram selecionados 63 pacientes de um total de 405 do estudo principal Core 64 que tinham realizado, além da Tomografia Computadorizada e da Cinecoronariografia, a Cintilografia de Perfusão Miocárdica com o objetivo principal de avaliar a correlação anatomofisiológica entre os diferentes métodos de imagem na avaliação da patologia coronariana de causa obstrutiva. Para isto, foram identificados através da avaliação anatômica quantitativa, tanto pela tomografia quanto pela cinecoronariografia, a presença de estenoses coronarianas causando obstruções entre 30 e 80% do lúmen arterial e correlacionados com a presença de defeitos perfusionais quantificados pela cintilografia de perfusão miocárdica equivalentes ao mesmo território coronariano. Após a análise estatística constatou-se que tanto a tomografia como a cinecoronariografia apresentam sensibilidade e especificidade apenas moderadas para prognosticar as alterações perfusionais detectadas pela cintilografia de perfusão miocárdica, no entanto, ambos os métodos são complementares e de fundamental importância na prática clínica para a manejamento diagnóstico e terapêutico dos pacientes portadores da doença coronariana isquêmica / Abstract: This work is related to a comparison between different modalities of imaging in the detection of obstructive coronary artery disease causing myocardial ischemia one of the biggest cause of death in developed countries using as base a multicenter trial Core 64. A retrospective analysis was performed using a subgroup of 63 patients of a total of 405 to evaluate the diagnostic accuracy of Multi-Detector Computed Tomography Angiography (MDCTA) and Conventional Coronary Angiography in detecting myocardial ischemia identified by Myocardial Perfusion Imaging (SPECT). Threshold of 30-80% of coronary artery stenosis identified by MDCTA and conventional coronary angiography were settled and correlated to the presence of myocardial ischemia of the same coronary artery territory. After statistical analyses a similar modest accuracy for quantitative coronary arterial stenosis assessment by both QCTA and QCA for identifying patients with myocardial perfusion were found, however either MDCTA, conventional coronary angiography and SPECT are complementary methods and play an import roll not only diagnosing but guiding clinical treatment in patients with coronary artery disease / Doutorado / Clinica Medica / Doutor em Clínica Médica
50

Interventioner för patientinformation för att minska ångest hos patienter som ska genomgå kranskärlsröntgen eller perkutan koronar intervention / Interventions for patient information to reduce anxiety in patients undergoing coronary angiography or perkutaneous coronary intervention

Woldamanuel, Yohannes January 2020 (has links)
Bakgrund: Kranskärlsröntgen eller perkutan koronar intervention är en av de mest avancerade diagnostiska och interventionella verktyg som har förbättrat livet för miljontals patienter med hjärt- och kärlsjukdom. Ingreppet är dock kopplat till en viss mängd komplikationer eller oönskade biverkningar. Trots att det är låg risk för dödlighet finns det betydande problematik kring psykologiska besvär både inför, under och efter ingreppen. Icke-farmalogiska interventioner som kan minska psykiskt lidande för patienter som genomgår Kranskärlsröntgen eller PCI är en viktig del i sjuksköterskans arbete.  Syfte: Syftet var att beskriva interventioner för patientinformation med syfte att minska ångest hos patienter som ska genomgå kranskärlsröntgen eller perkutan koronar intervention. Metod: En litteraturstudie, där artikelsökningar utfördes i databaserna PubMed, CINAHL, samt genom manuella sökningar från Google Scholar. Femton empiriska originalartiklar inkluderades. Dessa granskades och analyseras genom en integrerad analys. Resultat: Videobaserade informationsinterventioner visade sig vara effektiva för att minska ångestnivån i samband med kranskärlsröntgen eller perkutan koronar intervention i sex av studierna. Det fanns sju studier som använde multimodal utbildningsintervention och de minskade patientens ångestnivå före proceduren kranskärlsröntgen eller perkutan koronar intervention. Även erfarenhetsutbyte interventioner har visat statistisk signifikant skillnad på att minska ångest hos patienterna före proceduren. Slutsats: Litteraturöversikten visade att videobaserad och multimodal information och per-leed undervisning användes som interventioner för patientinformation med syfte att minska ångest hos patienter som genomgick kranskärlsröntgen och PCI. Vidare ger litteraturöversikten stöd för att användningen av interventioner för patientinformation i form av videobaserad information, stödd av broschyrer och muntlig diskussion med sjuksköterskeledda inlärningstillfällen har en betydande minskning av ångestnivån innan kranskärlsröntgen eller PCI procedurer. / Background: Coronary angiography or percutaneous coronary intervention is one of the most advanced diagnostic and interventional tools that has improved the lives of millions of cardiovascular patients. However, the procedure is linked to a certain amount of complications or unwanted side effects. Even though there is a low risk of mortality due to the procedure, there are significant problems regarding psychological distress both before, during and after the intervention. Non-pharmacological interventions that can reduce this psychological distress for patients undergoing angiography or percutaneous coronary intervention are an important part of the nurse's duty.  Aim: The aim was to describe interventions for patient information with the aim of reducing anxiety in patients undergoing coronary angiography or percutaneous coronary intervention.  Method: Three databases were chosen based on research by relevant scientific evidence identified during the pilot search test. PUBMED, CINAHL and Google Scholar are the databases used in the literature search. The selection resulted in a total of 15 articles on which this literature review is based.  Result: Video-based information interventions were found to be effective in reducing anxiety levels associated with coronary angiography or percutaneous coronary intervention in six of the studies. There were seven studies that used multimodal educational intervention for patients who underwent coronary angiography or percutaneous coronary intervention, which have shown a reduction in the anxiety level of patients prior to the procedure. Also, experience exchangeinterventions have shown statistically significant difference in reducing anxiety in patients prior to the procedure.  Conclusion: This literature review showed that video-based and multimodal information and per-leed instruction were used as interventions for patient information with the aim of reducing anxiety in patients who underwent coronary angiography and PCI. Furthermore, the literature review supports that the use of interventions for patient information in the form of video-based, supported by brochures and discussion with nurse-led learning opportunities has a significant reduction in anxiety levels before coronary angiography or PCI procedures.

Page generated in 0.0907 seconds