Spelling suggestions: "subject:"corrosao."" "subject:"borroso.""
71 |
Efeito do ácido fórmico na eletrodeposição de ligas Zn-Ni em substrato de açoPedroza, Graziella Aguiar Gomes 05 September 2013 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-04-11T18:01:53Z
No. of bitstreams: 1
Tese de Doutorado 2013_Graziella Pedroza.pdf: 5171330 bytes, checksum: b58915250d2789a638d82513ac7a363e (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-04-11T18:02:10Z (GMT) No. of bitstreams: 1
Tese de Doutorado 2013_Graziella Pedroza.pdf: 5171330 bytes, checksum: b58915250d2789a638d82513ac7a363e (MD5) / Made available in DSpace on 2016-04-11T18:02:10Z (GMT). No. of bitstreams: 1
Tese de Doutorado 2013_Graziella Pedroza.pdf: 5171330 bytes, checksum: b58915250d2789a638d82513ac7a363e (MD5) / A utilização dos depósitos de Zn-Ni eletrodepositados para melhorar a resistência à corrosão de chapas de aço revestidas tem atraído um interesse crescente porque oferece uma alternativa particularmente promissora para o Zn puro, devido às suas melhores propriedades mecânicas e de resistência à corrosão. Portanto, os estudos sobre os fatores que aumentam a eficiência de deposição e resistência à corrosão de eletrodepósitos das ligas Zn-Ni são altamente relevantes. Este trabalho descreve uma investigação sobre o efeito da adição de ácido fórmico (0,03; 0,07; 0,13; 0,20; 0,26; 0,40 e 0,53 mol/L) para o banho de revestimento de Zn-Ni, com teores de 10 e 18% de Ni, sobre a eficiência de deposição e resistência à corrosão em soluções de NaOH 2 M e NaCl 0,5 M. A adição de ácido fórmico no banho de deposição, independentemente do pH, promove um aumento da eficiência de deposição que está relacionado com a diminuição do pH e elevação da condutividade do banho de deposição causada pela adição do ácido fórmico. Foi observado um aumento da resistência à corrosão do depósito apesar do fato de que a adição de ácido fórmico diminui o teor de Ni nos depósitos. Também foi observado que a adição de ácido fórmico promove a evolução significativa de hidrogênio para concentrações superiores a 0,07 mol/L de ácido fórmico. Através da realização de ensaios de tração, foi constatado que a adição de ácido fórmico não altera as propriedades mecânicas do substrato, não ocorrendo, portanto, a fragilização por hidrogênio.
|
72 |
Estudo de Corrosão em Tubulações de Gás de CoqueriaVIEIRA, W. P. 17 December 2004 (has links)
Made available in DSpace on 2016-08-29T15:33:00Z (GMT). No. of bitstreams: 1
tese_632_Wander Pacheco.pdf: 3680408 bytes, checksum: cc6233e3fc39d64b4a351a4fbf59fbf6 (MD5)
Previous issue date: 2004-12-17 / Dentro do processo siderúrgico integrado, são produzidos diversos tipos de gases, sendo o mais importantes, sob o ponto de vista do valor energético, aqueles provenientes da produção de coque e de gusa, denominados, respectivamente, gás de coqueria (COG- Coke Oven Gas) e de Alto-Forno (BFG - Blast Furnace Gas). Estes Gases, se não forem adequadamente tratados, apresentam como característica uma atividade corrosiva intensa, devido à presença de umidade e de agentes corrosivos. Como resultados, as tubulações de aço para o transporte destes gases falham por entupimento e perfuração, como no caso do gás de Coqueira. Foram imensos em condensado, por até seis meses, corpos de prova em aço ASTM 283-C no interior de potes de selagem da tubulação de gás COG. A taxa de corrosão e a perda total de espessura foram determinadas por ensaios químicos de perda de massa. Acaracterização da composição do produto de corrosão foi realizada pela difratometria de raios-X, espectrofotometria no infravermelho, espectrometria de fluorescência, espectroscopia Mössbauer e pelas microscopias eletrônica de varredura e óptica.
Palavra chave: Corrosão, Gás de Coqueria, condensado
|
73 |
Obtenção de nanocompósitos na forma de filmes finos a partir do processo sol-gel, para proteção anticorrosiva de magnetos de NdFeB empregados em ortodontia.Itabaiana Sobrinho, Sisenando January 2014 (has links)
Programa de Pós-Graduação em Engenharia de Materiais. Rede Temática em Engenharia de Materiais, Pró-Reitoria de Pesquisa e Pós-Graduação, Universidade Federal de Ouro Preto. / Submitted by Maurílio Figueiredo (maurilioafigueiredo@yahoo.com.br) on 2014-07-17T19:48:25Z
No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
TESE_ObtençãoNanocompósitosForma.pdf: 7430806 bytes, checksum: 070da0f0ebdd2a474ee2b066590fb71b (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-07-18T17:55:21Z (GMT) No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
TESE_ObtençãoNanocompósitosForma.pdf: 7430806 bytes, checksum: 070da0f0ebdd2a474ee2b066590fb71b (MD5) / Made available in DSpace on 2014-07-18T17:55:21Z (GMT). No. of bitstreams: 2
license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5)
TESE_ObtençãoNanocompósitosForma.pdf: 7430806 bytes, checksum: 070da0f0ebdd2a474ee2b066590fb71b (MD5)
Previous issue date: 2014 / A despeito do êxito clínico dos magnetos na movimentação ortodôntica é relevante inibir através de um revestimento seguro o processo corrosivo decorrente das interações do meio bucal com os materiais magnéticos. Buscou-se neste estudo a obtenção de filmes finos obtidos pelo processo sol-gel a partir de soluções alcoólicas contendo isopropóxido de titânio (IV) como precursor do TiO2 e AgNO3 como precursor da prata metálica além do ácido metacrílico (AMA). Almejou-se com os filmes finos, uma melhor perfomance anticorrosiva dos magnetos NdFeB em ambiente ácido simulando o meio bucal. No sol formado foi empregada uma luz ultravioleta (UV-C) para promover a redução dos íons (Ag+ - Ago) com a finalidade antibacteriana do filme Ag/TiO2. Os filmes foram confeccionados pelo método dip-coating variando de 1 a 4 camadas e em seguida tratados termicamente a diferentes temperaturas. Para selecionar a solução mais apropriada a ser depositada na superfície dos substratos magnéticos, testou-se previamente os nanocompósitos híbridos Ag/TiO2, Ag/TiO2/AMA e TiO2/AMA depositados sobre lâminas de aço austenítico da série 316L e também sobre os magnetos NdFeB. Os filmes finos obtidos foram analisados com o auxílio de técnicas de microscopia de alta resolução que forneceram informações composicionais (EDS), morfológicas, topográficas e espessura do filme fino (MEV e microscopia de força atômica) e sobre a cristalinidade dos mesmos (difração de raios X). Foram realizados testes de resistência mecânica do filme TiO2/AMA por meio de nanoindentação. A eficácia anticorrosiva dos filmes finos TiO2/AMA depositados sobre os magnetos NdFeB foi testada analisando o comportamento do campo magnético das amostras e a microestrutura após a imersão dos mesmos em solução de ácido lático 1% por um período amostral de 70 dias. Empregou-se um teste estatístico ANOVA para avaliar a variação das médias dos mesmos. Os resultados mostraram que os magnetos revestidos em TiO2/AMA praticamente não sofreram corrosão, quando comparados com o controle, podendo os mesmos serem empregados na clínica ortodôntica para a movimentação dentária. No caso clínico ortodôntico relatado, os magnetos revestidos em TiO2/AMA, mostraram-se eficientes na geração de forças ortodônticas, bem como uma eficiência anticorrosiva corroborando as análises in vitro. __________________________________________________________________________________________ / ABSTRACT: Despite the clinical success of the magnets in orthodontic movement is relevant inhibit via a secure coating the corrosion process resulting from interactions of the oral environment with magnetic materials. In this study we attempted to obtain thin films obtained by the sol-gel process from alcoholic solutions containing titanium isopropoxide (IV) as the precursor of TiO2 and AgNO3 as silver metal precursor addition of methacrylic acid (AMA). Craved with thin films, better corrosion performance of NdFeB magnets in acidic environment simulating the oral environment. In the formed sol was used an ultraviolet light (UV-C) to promote the reduction of ions (Ag + - Aug) for the purpose of antibacterial film Ag/TiO2. The films were prepared by the dip-coating method ranging from 1 to 4 layers and then heat treated at different temperatures. To select the most appropriate solution to be deposited on the surface of the magnetic substrates, we tested previously Ag/TiO2 hybrid nanocomposites, Ag/TiO2/AMA TiO2/AMA and deposited on 316L austenitic steel series and also on the NdFeB magnets. The thin films were analyzed with the aid of microscopy techniques that provide high resolution information compositional (EDS), morphology, topography and thickness of thin film (SEM and atomic force microscopy) and the crystallinity of the same (ray diffraction X). Tests of mechanical strength of the film TiO2/AMA by nanoindentation. Later the thin film Ag/TiO2 was tested for its antibacterial and anticorrosive simultaneously. The effectiveness of corrosion TiO2/AMA thin films deposited on the NdFeB magnet was tested by analyzing the behavior of the magnetic field of the samples after soaking in solution of the same lactic acid 1% for a sample period of 70 days. Employed is an ANOVA to assess the variation of the averages of them. The results showed that the magnets coated TiO2/AMA hardly undergo corrosion when compared with the control, the same may be employed in orthodontic treatment for tooth movement. In orthodontic clinical case reported, the magnets coated in TiO2/AMA, were effective in generating orthodontic forces, as well as an anticorrosive efficiency corroborating the in vitro assays.
|
74 |
Efeitos de diferentes concentrações de dextrose e lipopolissacarídeo no comportamento corrosivo da liga Ti-6Al-4V com superfície usinada e tratada com duplo ataque ácidoFaverani, Leonardo Perez [UNESP] 26 August 2013 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-08-26Bitstream added on 2014-06-13T19:01:27Z : No. of bitstreams: 1
000737176.pdf: 2233924 bytes, checksum: be9f98eec022d58f2c75519afa00ec37 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivos: Avaliar o comportamento corrosivo da liga Ti-6Al-4V em função de sua superfície polida ou condicionada por meio de duplo ataque ácido, em simulador de fluidos corporais (SFC) com diferentes concentrações de dextrose (0; 5mM; 7,5 mM e 15 mM) e lipopopolissacarídeo (LPS) (0; 0,15 μg/mL; 15 μg/mL; 150 μg/mL), usados isolados ou associados. Materiais e Métodos: Discos de liga Ti-6Al-4V (2 mm de espessura e 15 mm de diâmetro) foram confeccionados com diferentes padrões de superfície. Para o ensaio eletroquímico (n=3), testes padrões como potencial de circuito aberto, espectroscopia de impedância eletroquímica (EIE) e teste potenciodinâmico foram conduzidos em solução de fluido corpóreo (SBF) com diferentes concentrações de dextrose e LPS. As superfícies dos discos foram caracterizadas pela microscopia eletrônica de varredura (MEV), microscopia de força atômica (MFA), e por meio da rugosidade de superfície e da microdureza. Os dados quantitativos foram analisados pelo teste de correlação de Pearson e T-teste independente, com nível de significância de 5%. Resultados: Nos parâmetros de corrosão, houve forte correlação do LPS com os valores de Ipass (densidade de corrente de passivação), Cdl (capacitância) e Rp (resistência de polarização) (p<0,05) para o titânio (Ti) com tratamento de superfície por duplo ataque ácido. A associação de dextrose e LPS foi correlacionada com Icorr (densidade de corrente de corrosão) e Ipass (p<0,05). Em relação à cinética de corrosão, os grupos tratados com ácido apresentaram aumento significante nos valores de Cdl e redução nos valores de Rp (P<0,05, T-teste). Quanto à topografia, houve aumento da rugosidade de superfície para ambas as superfícies (R2=0,726, p=0,0001 para Ti polido; R2=0,405, p=0,036 para Ti ácido). A microdureza do Ti polido diminuiu (p<0,05) e do Ti ácido aumentou (p=0,0001). A MFA... / Objectives: To analyse the corrosion behavior of Ti-6Al-4V with different surfaces (machined and modified by treatment with double acid-etching), on simulator body fluids (SBF) with different concentrations of dextrose (0; 5 mM, 7.5 mM and 15 mM) and lipopolysaccharide (LPS) (0; 0.15 μg/mL; 15 μg/mL; 150 μg/mL), used isolated or in combination. Materials and Methods: Ti-6Al-4V disks (2 mm in thickness and 15 mm in diameter) were fabricated with different surfaces. For electrochemical assay (n = 3), open circuit potential, electrochemical impedance spectroscopy (EIS) and potentiodynamic tests were conducted in SBF with different concentrations of dextrose and LPS. The surfaces of the disks were characterized by scanning electron microscopy (SEM), atomic force microscopy (AFM) and by surface roughness and microhardness. Data were analyzed by Pearson correlation and independent t-test at a significant level of 5%. Results: For the corrosion parameters, a strong correlation of LPS with Ipass (passivation current density), Cdl (capacitance) and Rp (polarization resistance) values (P <.05) for Ti surface treated by double acid- etching was noted. The combination of dextrose and LPS was correlated with Ipass and Icorr (corrosion current density) (P <.05). Regarding the corrosion kinetics the acid-treated groups showed significant increase in Cdl values and reduced values of Rp (P <.05, T-test). In terms of topography, there was an increase in surface roughness for both surfaces (R2 = 0.726, p = 0.0001 for machined Ti, R2 = 0.405, p = 0.036 for Ti acid). The machined Ti exhibited reduction in microhardness (P <.05), while Ti acid showed increased microhardness (p = 0.0001) vs baseline. The AFM showed changes in the microstructure of Ti by increasing the thickness of surface mainly in the association of dextrose and LPS. Conclusions: The combination of dextrose ...
|
75 |
Estudo do comportamento eletroquímico e da resistência à corrosão de eletrodepósitos de zinco e ligas de zinco em solução de NaCL e na presença de oxi-ânions do grupo VIBDutra, Conceição Aparecida Matsumoto [UNESP] 22 October 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:50Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-10-22Bitstream added on 2014-06-13T19:06:58Z : No. of bitstreams: 1
dutra_cam_dr_guara.pdf: 4819005 bytes, checksum: 73e78233a4fdf5d98fd8f747070d5fdc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os revestimentos de zinco são os mais amplamente utilizados na proteção do aço contra a corrosão. Atualmente, estes vêm sendo substituídos por ligas, como o Zn- Ni, pois têm revelado melhores propriedades mecânicas, maior resistência à corrosão quando comparados aos revestimentos de zinco de mesma espessura, além de poderem ser aplicados em temperaturas mais elevadas. Outros revestimentos de ligas de zinco formados com elementos do grupo VIIIB têm se mostrado promissores por apresentarem propriedades semelhantes e protegerem o aço por ação galvânica. Neste trabalho, eletrodepósitos de Zn, Zn-12%Ni, Zn-0,6%Co e Zn-<3%Fe-0,6%Co obtidos sobre aço SAE 1010, a partir de banhos alcalinos comerciais foram tratados por cromatização e caracterizados quanto às propriedades mecânicas, morfologia, comportamento eletroquímico e resistência à corrosão em solução de NaCl 3,5% e na presença de oxi-ânions do grupo VIB. Os estudos foram realizados através de medidas de microdureza, rugosidade, MEV, EDS, DRX e técnicas eletroquímicas. Dentre os eletrodepósitos estudados, o de Zn-Ni mostrou maior valor de rugosidade, enquanto os demais apresentaram resultados próximos aos do substrato de aço. As ligas Zn-Ni e Zn-Fe-Co apresentaram maior dureza em relação ao Zn. Através de DRX foi verificado que os eletrodepósitos são cristalinos, sendo identificada na liga Zn-Ni a presença das fases g (Ni5Zn21) e d (Ni3Zn22), responsáveis pela sua maior resistência à corrosão. As ligas tratadas por cromatização revelaram maior resistência à corrosão, tanto nos ensaios de salt spray, como nos ensaios eletroquímicos. O principal produto de corrosão encontrado sobre os eletrodepósitos, após os ensaios de salt spray e de imersão em solução de NaCl 3,5 %, foi o Zn5(OH)8Cl2.H2O, não sendo detectados óxidos ou hidróxidos formados... / The zinc coatings are the most widely used in protecting steel against corrosion. Currently, these are being replaced with alloys such as Zn-Ni, for they have shown better mechanical properties, higher corrosion resistance when compared to zinc coatings of equal thickness, and can be applied at higher temperatures. Other zinc alloys coatings formed with elements of group VIIIB were shown to be promising because they have similar properties and protect the steel by galvanic action. In this study, electrodeposited Zn, Zn-12% Ni, Zn-0.6%Co and Zn-<3% Fe-0.6% Co coatings obtained on steel SAE 1010, from alkaline baths have been treated with commercial chromate and characterized by the mechanical properties, morphology, electrochemical behavior and corrosion resistance in NaCl 3.5% and in presence of oxy-anions of group VIB. The studies have been performed by measurements of hardness, roughness, optical microscopy, SEM, EDS, XRD and electrochemical techniques. Among the studied electrodeposits, Zn-Ni showed higher roughness, while others showed results similar to the steel substrate. Ni-Zn and Zn-Fe-Co alloys showed higher hardness in relation to Zn. By XRD it has been observed that electrodeposits are crystalline, being identified in Zn-Ni alloy phases presence of g (Ni5Zn21) and d (Ni3Zn22), responsible for its higher corrosion resistance. Alloys treated by chromate have revealed greater corrosion resistance both in salt spray tests and in electrochemical tests. The main corrosion product found on electrodeposits, after salt spray and immersion in 3.5 % NaCl solution tests, was Zn5(OH)8Cl2.H2O, not being detected oxides or hydroxides formed with metals. All electrodeposits protect steel by galvanic action, for they have presented corrosion potentials more negative than that of steel. Chromate or molybdate addition to the electrolyte further extends the stability range, which shows... (Complete abstract click electronic access below)
|
76 |
Estudo morfológico e cinético da corrosão por pites em liga de alumínio 1050Pereira, Marinalda Claudete [UNESP] 24 November 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:51Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-11-24Bitstream added on 2014-06-13T21:05:03Z : No. of bitstreams: 1
pereira_mc_dr_guara.pdf: 4232710 bytes, checksum: ea4f89d3947bfa85e4d906d61f044116 (MD5) / O objetivo deste trabalho foi estudar as características morfológicas da corrosão localizada na liga de alumínio 1050 e a cinética de crescimento em tamanho dos pites induzidos por ensaios de imersão estática em solução de NaCl, pH 6,0, aerada naturalmente à temperatura ambiente. As amostras foram examinadas antes e após o ensaio de corrosão por microscopia ótica e microscopia eletrônica de varredura e, posteriormente foram analisadas através de um método de captura, processamento digital e análise de imagens, recentemente desenvolvido pelo grupo de Corrosão e Eletroquímica da FEG/UNESP. Exames na superfície da liga após 168h de imersão em NaCl 0,0043 mol/L indicaram um ataque localizado na matriz adjacente às partículas Al:Fe:Si e Al:Fe as quais revelaram um caráter catódico. Mediante análise da variação temporal dos parâmetros obtidos concluiu-se que a área dos pites não muda significativamente enquanto a densidade e a fração de área corroída aumentam com o tempo. A variação temporal indicou que velocidade de corrosão, em termos de propagação superficial, diminui com o tempo de imersão. As características morfológicas e os tamanhos dos pites nos perfis da superfície corroída foram estudados. Os pites induzidos não podem ser representados por uma única geometria, senão pela distribuição morfológica seguinte: i) sem exclusão das cavidades: hemisférico > transição A > transição B > irregular > cônico > cilíndrico; ii) com exclusão das cavidades: hemisférico > transição A > transição B > irregular ~cônico, sem evidências dos pites cilíndricos. Os pites mais profundos foram encontrados especialmente na classe de transição B. A velocidade de crescimento em profundidade (P) ou em largura (L) dos pites foi melhor representada, após a exclusão das cavidades, mediante a lei cinética seguinte:... / This work aim has beem to study the morphologic characteristics of localized corrosion on aluminum alloy 1050 and the growth kinetics in size of pits induced by static immersion tests in NaCl solution, pH 6.0, naturally aerated at room temperature. The samples have been examined before and after the corrosion test by optical microscopy and scanning electron microscopy and subsequently analyzed by a capturing method, digital processing and image analysis, recently developed by the Corrosion and Electrochemistry group of FEG / UNESP. Investigations on the alloy surface after 168h immersion in NaCl 0.0043 mol / L has showed a localized attack on the matrix adjacent to the particles Al: Fe: Si and Al: Fe which have disclosed a cathodic character. By analyzing the temporal variation of obtained parameters it has been concluded that pits area does not change significantly while density and corroded area fraction increase with the time. Temporal variation has indicated that corrosion rate in terms of propagating surface, decreases with immersion time. The morphological characteristics and pits sizes in the corroded surface profiles have been studied. The induced pits may not be represented by a unique geometry, but by the following morphologic distribution: i) without cavities exclusion: hemispheric > transition A > transition B > irregular > conical > cylindrical ii) excluding cavities: hemispheric > transition A > transition B > irregular ~ conical, without cylindrical pits evidence. The deepest pits have been found particularly in transition B class. The pits growth rate in depth (P) or in width (L) has been better represented, after cavities exclusion, by the following kinetics law: P or L = ktm, with k and m empirical values that depend on a combination of different factors
|
77 |
Estudo de corrosão das fases componentes de amálgamas dentáriosAcciari, Heloisa Andréa [UNESP] January 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:05Z (GMT). No. of bitstreams: 0
Previous issue date: 2001Bitstream added on 2014-06-13T18:46:14Z : No. of bitstreams: 1
acciari_ha_dr_araiq.pdf: 3985367 bytes, checksum: 669d0836181f115365689e398ad14653 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Este trabalho consistiu de um estudo da resistência à corrosão relativa de um amálgama dentário comercial e de suas principais fases constituintes, pelo uso de técnicas eletroquímicas, em meio salino e aerado que simula a agressividade do ambiente bucal. Os amálgamas dentários são formados pela reação do mercúrio com uma liga original em pó que contém predominantemente Ag, Sn e Cu, podendo também conter Zn ou outros elementos em menores proporções, resultando numa estrutura metalúrgica complexa e multifásica, com a presença das seguintes fases: γ1-Ag2Hg3 - matriz; γ-Ag3Sn - a segunda fase mais proeminente na microestrutura dos amálgamas dentários; γ2-Sn7-8Hg - a mais suscetível à corrosão dentre todas aquelas que compõem a microestrutura dos amálgamas dentários, de acordo com a literatura especializada; a composição eutética Ag-Cu (72%Ag, 28%Cu) - um componente adicionado às ligas mais modernas com o objetivo de reduzir a quantidade de γ2-Sn7Hg formada durante a reação de amalgamação e, neste sentido, aumentar a resistência à corrosão no meio bucal; e as fases do sistema Cu-Sn, ε-Cu3Sn e η'-Cu6Sn5 presentes em menor quantidade. Dada a natureza multifásica da microestrutura de amálgamas dentários, para este estudo foram elaboradas ligas metálicas binárias com composições químicas correspondentes às fases presentes em sua microestrutura. As ligas que contêem mercúrio, γ1-Ag2Hg3 e γ2- Sn7Hg, foram preparadas de acordo com as normas contidas na Especificação n. 1 para amálgamas dentários, da Associação Dentária Americana (ADA). As demais, correspondentes aos sistemas Ag-Cu, Ag-Sn e Cu-Sn foram preparadas pelos processos metalúrgicos convencionais de fundição, com o propósito de se reproduzir as principais fases que podem estar presentes na estrutura metalúrgica dos amálgamas... / Dental amalgams are formed by the reaction of mercury with a powder alloy containing mainly Ag, Sn, Cu and Zn, and have a complex metallurgical structure which can contain up to six phases. Their observed corrosion is thus a complex process, which involves contributions from each of the phases present as well as intergranular corrosion. It is thus of interest to investigate the corrosion of individual phases present in dental amalgams. Some of the products of the reaction are particles of the original alloy which did not react during the amalgamation process such as, γ-Ag3Sn and the Ag-Cu eutectic. Other products are the γ- phase of the silver-mercury system, designated γ1-Ag2Hg3, the γ-phase of the tin-mercury system, designated γ2-Sn7-8Hg, and intermetallic compounds of the tin-copper system, ε-Cu3Sn and η'-Cu6Sn5. The purpose of this work was to evaluate the corrosion resistance of the phase components of dental amalgams: the matrix phase of the microstructure, γ1-Ag2Hg3; the second more prominent, γ-Ag3Sn; the phase most susceptible to corrosion in the oral cavity, according to the literature, γ2-Sn7Hg; and spherical particles of the Ag-Cu eutectic (72% Ag, 28% Cu), a component of the more modern powder alloys, the objective being to reduce the quantity of γ2-Sn7Hg formed during the amalgam reaction and in this way increase its corrosion resistance. The Ag-Hg and Sn-Hg alloys were made in the correct stoichiometric proportions, taking into account the phase diagrams, by mechanical amalgamation and moulding under high pressure following the criteria adopted by the American Dental Association, Specification No. 1. The commercial dental amalgam employed in this study was Dispersalloy, a copper enriched alloy, type blended. The Ag-Sn, Ag-Cu and Cu-Sn alloys were prepared by heating the components until they were completely melted, and then the melt was poured into a mould...(Complete abstract click electronic access below)
|
78 |
Estudo da carburização de tubos de ligas de Fe-Cr-Ni aplicadas em fornos de piróliseBiehl, Luciano Volcanoglo January 2002 (has links)
Durante sua utilização, tubos que operam na pirólise de substâncias orgânicas sofrem degradação estrutural resultante dos mecanismos de carburização que, em geral, levam à falha dos tubos. A carburização decorre da quantidade de carbono disponível na pirólise, que chega a formar uma camada intensa de coque no interior dos tubos. Para a retirada do coque, é introduzido vapor no intuito de queimá-lo que, adicionalmente, deixa carbono na superfície para a carburização. Este trabalho analisa os aspectos metalúrgicos envolvidos no ataque das liga Fe-Cr- Ni através da carburização, onde falhas catastróficas podem ocorrer devido às tensões térmicas geradas nas paradas de retirada do coque formado. Os tubos usados são fabricados com as ligas HP40 e HPX. Ligas ricas em cromo e níquel são utilizados; no caso do níquel a estabilização da estrutura austenítica e do cromo pela formação de uma camada protetora de óxido. No entanto, tempos prolongados de emprego da liga pode gerar quebra da barreira protetora e, então, proporcionar a difusão do carbono para o material, causando mudanças microestuturais que irão afetar as propriedades metalúrgicas. Neste trabalho foram analisadas microestruturas de ligas com 25% Cr e 35% Ni que operaram por 20.000 e 37.000 horas, bem como a realização de uma série de tratamentos térmicos com ligas 25% Cr 35% Ni e 35% Cr 45% Ni sem uso, a fim de se estabelecer à relação existente entre a difusão do carbono e a microestrutura resultante. De posse destes dados, foram realizadas análises em microscopia, ensaios mecânicos, dilatometria e modelamento das tensões térmicas geradas nas paradas de decoking. Foi, também, desenvolvido uma metodologia capaz de relacionar a espessura da camada difundida de carbono com o magnetismo existente na superfície interna causada pela formação de precipitados magnéticos.
|
79 |
Estudo do efeito inibidor do solicato de sódio na corrosão de uma liga de ali-mg-si, em meio de diferentes concentrações de cloretoSouza, Júpiter Palagi de January 1979 (has links)
No presente trabalho, estudou-se o efeito inibidor do silicato de sódio na corrosão de uma liga de AI-Mg-Si em meio arejado e desarejado, contendo quantidades variadas de Ion cloreto no pW = 10,O . Nos diferentes tipos de ensaios realizados, tais como, traçado de curvas de polarização, ensaios galvanostáticos e com par galvânico, utilizou-se corpos de prova anodizados ou polidos. Os resultados experimentais mostraram que 1 g/l de silicato de sódio neutro de composição Na2O : 3.3 SiO2, demonstrou total efeito inibidor da corrosão da liga de A1-Mg-Si, em solução contendo até 60 p.p.m. de NaC1. Em concentrações de 1060 p.p,m. e maiores de NaC1, o silicato mostrou apenas efeito retardador da corrosão, com diminuição da incidência de pites. A análise dos produtos de corrosão, formadas sobre a superficie dos pites, feita usando-se raio-X e espectroscopia de infravermelho, mostrou que esses produtos têm estrutura amorfa e contêm silicato e grupos hidroxila. Finalmente, medidas de capacitância da dupla camada, confirmaram a existência de uma película que se forma sobre a superfície da liga de alumínio, quando em solução de silicato. / The present work analyses the inhibitor effect of sodium silicate on the corrosion of an A1-Mg-Si alloy in aereated and deaereated solutions containing varying amounts of chlorfde ions, at pH = 10.0 . Anodized and polished especimens were used in all kinds of experiments performed so as polarization curves, galvanostatic tests and galvanic couple. The experimental results showed that 1 g/l of neutral sodium silicate, whose composition was Na20: 3.3 SiO2 , presented a total inhibiting effect on the corrosion of the A1-Mg-SI alloy in aqueous solutions containing up to 60 p.p.m. NaCl. In concentrations of 1060 p.p.m. NaCl, and higher, the silicate showed only a partial inhibiting effect, diminishing pitting nucleation and propagation. Analyses of the corrosion products fomed over the effects, using X-rays and infrared spectroscopy, showed that these products were amorphous, and confirmed the presence of silicate and OH- groups. Measurements of double layer capacitance pointed to the existence of a film (probably containing aluminum silicate) that grew on the aluminum surface when imersed in a silicate solution.
|
80 |
Corrosão de vários materiais metálicos em álcool etílico hidratado combustível e sua inibição a 25 graus CAmaral, Solange Teresinha Guidali January 1984 (has links)
Estudou-se o comportamento à corrosão de diversos materiais metálicos como aço, cobre, latão e pares galvânicos (aço-latão) em álcool etilico combustível (91.1 - 93.9 -INPM) adicionado de várias substâncias a fim de avaliar possíveis efeitos inibidores ou aceleradores da corrosão. Foi verificado a influência na corrosão, de ion cloreto, acetato de sódio, ácido benzóico, trietanolamina, butinodiol e um inibidor comercial. O acetato de sódio seguido do produto comercial se revelaram os melhores aditivos sob o ponto de vista da inibição da corrosão. A adição de cloreto, como um possível contaminante foi estudada e obteve-se um aumento bastante grande na taxa de corrosão. A adição de perclorato de potássio ao álcool combustível normalmente utilizado para aumentar a condutividade da solução nos ensaios eletroquímicos, mostrou ser prejudicial por modificar apreciavelmente as características do comportamento à corrosão dos materiais ensaiados, aumentando-a ou diminuindo-a conforme o caso. / A study has been made on the corrosion of several metallic materials steel, copper, brass and galvanic couples (steel-brass) in combustible ethyl alcohol (911 - 93.9' INPM), with small additions of different substances to evaluate possible effects Of inhibition or stimulation of corrosion. The influence of chloside ions, sodium acetate, benzoic acid, triethanolamine, butynediol and a commercial inhibitor was verified. Under the corrosion inhibition point of view, sodium acetate and the commercial inhibitor in this order have demonstrated to be the best additives. Chloride addition as principal contaminant was investigated and resulted in a large increase of the corrosion rate. Potassium perchlorate, usualy added to combustible alcohol to increase solution conductivity in eletrochemical tests, demonstrates to be disadvantageous, modifying appreciably the behavior towards corrosion of tested materials increas,ing or decreasing it according each case.
|
Page generated in 0.0412 seconds