• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • Tagged with
  • 8
  • 8
  • 6
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influência da fonte de fotoativação sobre a resistência de união entre um pino de fibra de vidro e um cimento resinoso, em diferentes profundidades.

Freitas, Gustavo Pinheiro de January 2007 (has links)
82f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T18:03:32Z No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T12:35:27Z (GMT) No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) / Made available in DSpace on 2013-05-08T12:35:27Z (GMT). No. of bitstreams: 1 Dissertacao Gustavo de Freitas.pdf: 4255443 bytes, checksum: e1c6da0abf59a84ad236924bb2db824b (MD5) Previous issue date: 2007 / O objetivo deste trabalho foi avaliar a resistência de união entre um pino de fibra de vidro e um cimento resinoso. Trinta cilindros de resina composta foram confeccionados e pinos de fibra de vidro (ReforPost - Angellus) cimentados em seu interior com um cimento resinoso dual (RELY-X – 3M). A fotoativação do cimento foi feita variando-se as fontes de luz (Halógena e LED). Cada um dos 30 cilindros foi cortado em três partes (terço cervical, médio e apical), resultando 90 discos que foram divididos em 09 grupos (n=10): Grupo 1- Oc: Optlight Plus – GNATUS, terço cervical; Grupo 2-Om: Optlight Plus – GNATUS, médio; Grupo 3-Oa: Optlight Plus – GNATUS, apical; Grupo 4-RC: RADII – SDI, cervical; Grupo 5 Rm: RADII – SDI, médio; Grupo 6-RC: RADII – SDI, apical; Grupo 7- Ec: Elipar Freelight2 – 3M, cervical; Grupo 8-Em: Elipar Freelight2 – 3M, médio; Grupo 9- Ea: Elipar Freelight2 – 3M, apical. Todos os grupos foram submetidos ao ensaio de tração diametral (DTS) em uma máquina de ensaios (EMIC 2000) até a fratura. As médias dos grupos em Mpa foram: G1-Oc: 25,08 (4,20); G2-Om: 23,44 (4,64); G3-Oa: 20,88 (3,62) G4- Rc: 22,86 (5,93); G5-Rm: 22,12 (6,72); G6-Ra: 22,04 (5,61); G7-Ec: 26,01 (3,33); G8-Em: 19,81 (6,09); G9-Ea: 17,74 (4,14). A análise estatística dos dados permitiu concluir que, o grupo G 9–Ea apresentou a menor resistência à tração diametral demonstrando diferença estatisticamente significante quando comparado com os grupos G7-Ec e G1-Oc e não houve influência das diferentes fontes de luz. Com base nestes resultados também podemos afirmar que o aparelho LED (RADII – SDI) apresentou valores de DTS constantes em todos os terços analisados. / Salvador
2

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz

Conti, Elaine Cristina Guerbach [UNESP] January 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2006Bitstream added on 2014-06-13T20:41:44Z : No. of bitstreams: 1 conti_ecg_dr_arafo.pdf: 812838 bytes, checksum: c0f89cff921f9b0a2343ffde10308ae3 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5.
3

Evaluation of multiple and single emission peak light emitting diode light curing units effect on the degree of conversion and microhardness of resin-based pit and fissure sealant

Alqahtani, Saleh Ali M. January 2017 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / Objective: The objective was to assess a multiple emission peak light-emitting-diode (LED) light-curing unit (LCU) by measuring the polymerization efficiency through the degree of conversion (DC) and Knoop microhardness (KHN) of a resin-based pit and fissure sealant at various light curing times and two distances compared to a single emission peak LED LCU. Method: Sixty disks of resin-based pit and fissure sealant (Delton, DENTSPLY, York, PA) samples (6x1mm) were fabricated (n=5/LCU/group). Prepared samples were polymerized using 10, 20 and 40 second curing time at 2 or 4 mm curing distances. The irradiance and radiant exposure received on the top/bottom surfaces of the samples were measured using the Managing Accurate Resin Curing-Resin Calibrator (MARC-RC) system. The samples were stored at 37°C for one hour. Then, the DC (n=3/surface) and KHN (n=5/surface) measurements were collected on the top and bottom surfaces using Attenuated Total Reflection-Fourier Transform Infrared Spectroscopy (ATR-FTIR) and a microhardness tester (Instron) utilizing 25-gm at 10 seconds dwell time, respectively. Multiple-way ANOVA was performed followed by Tukey test (α=0.05). Result: The irradiance from the multiple emission peak LED LCU was significantly higher than the single emission peak LED LCU (1312.6 and 768.3 mW/cm2) respectively. Moreover, the multiple emission peak LED LCU displayed significantly higher DC (82.5%) and microhardness (26.2 KHN) compared to the single emission peak LED LCU (75.5% DC and 21.2 KHN) when curing samples at 2 and 4 mm curing distances assessed using 10, 20 and 40-second curing times. The 10 second cure at 4 mm showed significantly lower DC and KHN values compared to the other groups. Conclusion: The multiple emission peak LED LCU demonstrated significantly higher irradiance, DC and KHN compared to the single emission peak LED LCU on a resin-based pit and fissure sealant at 2 and 4 mm curing distances and 10, 20 and 40 second curing times. Therefore, the multiple emission peak LED LCU performed higher than the single emission peak LED LCU.
4

Avaliação por microdureza Vickers da profundidade de polimerização de cimentos resinosos na cimentação de pinos de fibra de vidro empregando diferentes fontes de luz /

Conti, Elaine Cristina Guerbach. January 2006 (has links)
Orientador: José Roberto Cury Saad / Banca: Patrícia dos Santos Jardim / Banca: Luiz Alberto Plácido Penna / Banca: Osmir Batista de Oliveira Júnior / Banca: Marcelo Ferrarezi de Andrade / Resumo: O objetivo desse estudo foi avaliar a microdureza Vickers de um cimento resinoso químico (C&B Cement - Bisco) e um de ativação dual (RelyX ARC - 3M ESPE), fotopolimerizado por diferentes fontes de luz, em função de diferentes profundidades do canal radicular, na cimentação de pinos de fibra de vidro. Os aparelhos fotopolimerizadores empregados foram: Optilux 360 (Demetron) - luz halógena; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. Nenhuma diferença estatisticamente significante foi observada nos valores de microdureza Vickers, dos terços cervical, médio e apical do canal radicular, para o cimento resinoso químico (G1), e os terços cervicais do cimento resinoso dual, para todos os aparelhos fotopolimerizadores (G2, G3 e G4) (p>0.05). Porém, o aparelho de luz halógena (G2) e o LED UltraLume 5 (G4) apresentaram comportamentos semelhantes, proporcionando uma diminuição gradativa nos valores médios de microdureza do cimento resinoso dual, do terço cervical para o apical (p<0.001). Os menores valores de microdureza foram encontrados nos terços apical do sistema RelyX ARC fotopolimerizado com luz halógena ou com LED UltraLume 5. / Abstract: This study evaluated the Vickers microhardness of a chemically cured resin cement (C&B Cement - Bisco) and a dual cure cement (RelyX ARC - 3M ESPE), light cured by different light sources, according to the different root canal depths, for luting of glass fiber posts. The light curing units employed were Optilux 360 (Demetron) - halogen lamp; Radii (SDI) - LED; UltraLume 5 (Ultradent) - LED. No statistically significant difference was observed in Vickers microhardness values at the cervical, middle and apical root thirds for the chemically cured resin cement (G1), and at the cervical third for the dual resin cement, for all light curing units (G2, G3 and G4) (p>0.05). However, the halogen lamp unit (G2) and LED UltraLume 5 (G4) presented similar performance, providing gradual reduction in mean microhardness values for the dual resin cement from the cervical to the apical third (p<0.001). The lowest microhardness values were found at the apical third for the system RelyX ARC light cured with halogen lamp or LED UltraLume 5. / Doutor
5

Efeito da fonte de luz e enxaguatórios bucais na microdureza longitudinal de resinas compostas diretas. Análise complementar por espectroscopia Raman / Effect of the light curing units and mouthrise in the longitudinal microhardness of direct composite resins. Backing analysis for Ramam spectroscopy

Silva, Flaviane Renó Gonzaga 26 June 2009 (has links)
Neste estudo foi realizada avaliação longitudinal da microdureza Vickers e análise complementar do grau de conversão, de resinas compostas diretas, pelo método de espectroscopia Raman. As resinas compostas estudadas (M1: Charisma, M2: Z100 e M3: Filtek Supreme) foram fotopolimerizadas por diferentes fontes de luz (F1: Diodo emissor de F2: Luz e Halógena) e submetidos à ação de diferentes enxaguatórios bucais (S1: Saliva artificial, S2: Listerine e S3: Cepacol) e analisadas nas diferentes profundidades (P1 = 2mm, P2 = 4mm e P3 = 6mm). Para análise de microdureza Vickers - VHN (kg/cm3) foram confeccionados 07 corpos-de-prova (cp) para cada condição experimental (total = 180) por meio de matrizes em teflon, constituídas de dois dispositivos, o primeiro contendo uma cavidade de 02X04X06mm de base arredondada e um segundo dispositivo de superfície lisa que foi contraposto ao primeiro, as leituras foram realizadas 24 horas após a confecção dos cp por meio do microdurômetro Shimadzu HMV-200. A análise espectroscópica foi realizada por espectroscopia Raman (espalhamento Raman) (GC), para tal foram selecionadas aleatoriamente 06 amostras de cada resina estudada, das condições experimentais propostas (dentre as utilizadas para o teste de microdureza) e obtidos 06 cp para cada profundidade (total = 18 para cada resina), conforme metodologia preconizada pelo Laboratório do Departamento de Química da FFCLRP-USP. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar que para o fator Profundidade os valores de VHN e GC foram maiores para P1 e menores para P3 nas resinas R1 e R3; para o fator Fonte F2 determinou maiores valores de VHN para R1 e R2 e maiores valores de GC para todas as resinas analisadas; para o fator Solução S3 determinou maiores valores de VHN para todas as resinas, no entanto, não houve diferença no GC entre as Soluções; entre as resinas R2>R3>R1 para VHN e para DC R3>R1>R2. Logo, todos os fatores analisados influenciaram a microdureza e o grau de conversão das resinas. / In this study was made longitudinal evaluation of the microhardness Vickers and backing analysis of the conversion degree was accomplished, of direct composite resins, by the method of Raman spectroscopy. The composite resins studied (M1: Charisma, M2: Z100 and M3: Filtek Supreme) was photopolymerized by different sources of light (F1: light emitting diode and F2:quartz-tungsten-halogenous) and submitted to the action of different mouthrise (S1: Artificial saliva, S2: Listerine and S3: Cepacol) and analysed in the different depths (P1= 2mm, P2= 4mm e P3= 6mm). For analysis of microhardness Vickers - VHN (kg/cm3) were confectioned 07 samples for each experimental condition (total = 180) by means of matrix in teflon, constituted of two devices, first containing a socket of 02X04X06mm of rounded base and a second dispositive of smooth surface that was opposed to first, the readings were accomplished 24 hours after the confection of sample by means of the equipmente Shimadzu HMV-200. The spectroscopic analysis was accomplished by Raman spectroscopy (Raman scattering) (DC), for such 06 samples of each studied resin were selected randomly, of the experimental conditions proposals (amongst the used ones for the microhardness test) e obtained 06 samples for each depth (total=18 for each resin), as methodology praised for the Laboratory of the Department of Chemistry of the FFCLRP-USP. The obtained values were submitted to the analysis of variance (ANOVA) and, for the individual matchings, were accomplished the test of Tukey (p<0,05). The results had allowed to observe that for the factor Depth the values of VHN and DC were bigger for P1 and lesser for P3 in the resins R1 and R3; for the factor F2 Source it determined greaters values of VHN for R1 and R2 and greaters values of DC for all the analysed resins; for the factor S3 Solution it determined greaters values of VHN for all the resins, however, it did not have difference in the DC between the Solutions; between resins R2>R3>R1 for VHN and for DC R3>R1>R2. Soon, all the analysed factors had influenced the microhardness and the degree of conversion of resins.
6

Efeito da fonte de luz e enxaguatórios bucais na microdureza longitudinal de resinas compostas diretas. Análise complementar por espectroscopia Raman / Effect of the light curing units and mouthrise in the longitudinal microhardness of direct composite resins. Backing analysis for Ramam spectroscopy

Flaviane Renó Gonzaga Silva 26 June 2009 (has links)
Neste estudo foi realizada avaliação longitudinal da microdureza Vickers e análise complementar do grau de conversão, de resinas compostas diretas, pelo método de espectroscopia Raman. As resinas compostas estudadas (M1: Charisma, M2: Z100 e M3: Filtek Supreme) foram fotopolimerizadas por diferentes fontes de luz (F1: Diodo emissor de F2: Luz e Halógena) e submetidos à ação de diferentes enxaguatórios bucais (S1: Saliva artificial, S2: Listerine e S3: Cepacol) e analisadas nas diferentes profundidades (P1 = 2mm, P2 = 4mm e P3 = 6mm). Para análise de microdureza Vickers - VHN (kg/cm3) foram confeccionados 07 corpos-de-prova (cp) para cada condição experimental (total = 180) por meio de matrizes em teflon, constituídas de dois dispositivos, o primeiro contendo uma cavidade de 02X04X06mm de base arredondada e um segundo dispositivo de superfície lisa que foi contraposto ao primeiro, as leituras foram realizadas 24 horas após a confecção dos cp por meio do microdurômetro Shimadzu HMV-200. A análise espectroscópica foi realizada por espectroscopia Raman (espalhamento Raman) (GC), para tal foram selecionadas aleatoriamente 06 amostras de cada resina estudada, das condições experimentais propostas (dentre as utilizadas para o teste de microdureza) e obtidos 06 cp para cada profundidade (total = 18 para cada resina), conforme metodologia preconizada pelo Laboratório do Departamento de Química da FFCLRP-USP. Os valores obtidos foram submetidos à análise de variância (ANOVA) e, para as comparações individuais, foi realizado o teste de Tukey (p<0,05). Os resultados permitiram observar que para o fator Profundidade os valores de VHN e GC foram maiores para P1 e menores para P3 nas resinas R1 e R3; para o fator Fonte F2 determinou maiores valores de VHN para R1 e R2 e maiores valores de GC para todas as resinas analisadas; para o fator Solução S3 determinou maiores valores de VHN para todas as resinas, no entanto, não houve diferença no GC entre as Soluções; entre as resinas R2>R3>R1 para VHN e para DC R3>R1>R2. Logo, todos os fatores analisados influenciaram a microdureza e o grau de conversão das resinas. / In this study was made longitudinal evaluation of the microhardness Vickers and backing analysis of the conversion degree was accomplished, of direct composite resins, by the method of Raman spectroscopy. The composite resins studied (M1: Charisma, M2: Z100 and M3: Filtek Supreme) was photopolymerized by different sources of light (F1: light emitting diode and F2:quartz-tungsten-halogenous) and submitted to the action of different mouthrise (S1: Artificial saliva, S2: Listerine and S3: Cepacol) and analysed in the different depths (P1= 2mm, P2= 4mm e P3= 6mm). For analysis of microhardness Vickers - VHN (kg/cm3) were confectioned 07 samples for each experimental condition (total = 180) by means of matrix in teflon, constituted of two devices, first containing a socket of 02X04X06mm of rounded base and a second dispositive of smooth surface that was opposed to first, the readings were accomplished 24 hours after the confection of sample by means of the equipmente Shimadzu HMV-200. The spectroscopic analysis was accomplished by Raman spectroscopy (Raman scattering) (DC), for such 06 samples of each studied resin were selected randomly, of the experimental conditions proposals (amongst the used ones for the microhardness test) e obtained 06 samples for each depth (total=18 for each resin), as methodology praised for the Laboratory of the Department of Chemistry of the FFCLRP-USP. The obtained values were submitted to the analysis of variance (ANOVA) and, for the individual matchings, were accomplished the test of Tukey (p<0,05). The results had allowed to observe that for the factor Depth the values of VHN and DC were bigger for P1 and lesser for P3 in the resins R1 and R3; for the factor F2 Source it determined greaters values of VHN for R1 and R2 and greaters values of DC for all the analysed resins; for the factor S3 Solution it determined greaters values of VHN for all the resins, however, it did not have difference in the DC between the Solutions; between resins R2>R3>R1 for VHN and for DC R3>R1>R2. Soon, all the analysed factors had influenced the microhardness and the degree of conversion of resins.
7

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado

Firoozmand, Leily Macedo [UNESP] 29 July 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-07-29Bitstream added on 2014-06-13T20:11:59Z : No. of bitstreams: 1 firoozmand_lm_me_sjc.pdf: 463529 bytes, checksum: fe72af5f2a85d677bf7c84e0aa8b1439 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness.
8

Avaliação da microdureza superficial da resina composta fotopolimerizada por aparelho de luz halógena e de diodo(LED) em função de opacidade e ação do flúor fosfato acidulado /

Firoozmand, Leily Macedo. January 2005 (has links)
Orientador: Maria Amélia Máximo de Araújo / Banca: Maria Amélia Máximo de Araújo / Banca: Maria Antonia Pereira / Banca: João Carlos da Rocha / Resumo: O objetivo deste trabalho foi verificar a influência da opacidade de cor, tipos de aparelhos fotopolimerizadores (luz halogena X led azul) e aplicação tópica do FFA 1,23% na microdureza da resina composta. A resina composta Esthet-X (Dentisply), nas cores A2 e A2-O foram inseridas em uma matriz de aço-inoxidável em cavidades de 5mm de diâmetro e 2mm de profundidade e fotopolimerizadas por aparelhos; de luz halogena, XL 3000 (3M) ou de LED azul, Optilight LD II (Gnatus), por 40s. Formaram-se 4 grupos com trinta amostras, sendo analisadas a superfície e a base das amostras. Estas foram armazenadas em água destilada, por 24h e posteriormente embutidas em RAAQ. Realizou-se a leitura da microdureza inicial em Microdurômetro Digital Vickers, utilizando 50g de carga por 30s de permanência. A seguir, foi aplicado o FFA 1,23% por 48 min e uma segunda leitura da microdureza foi realizada. O teste estatístico de ANOVA e Tukey (5%) demonstrou que a microdureza da superfície foi sempre maior que a da base. O aparelho de luz halógena apresentou maiores valores médios de microdureza da resina (57,61 HV) que o aparelho de LED (42,53 HV). Foram encontradas diferenças significantes entre os valores médios de microdureza ao se variar a opacidade, sendo que em profundidade, a resina A2-O apresentou os menores valores. A aplicação do FFA 1,23% promoveu menores valores de microdureza na resina. A opacidade da resina composta, o tipo e fonte polimerizadora, bem como a utilização tópica do FFA 1,23% influenciam no grau de microdureza resina. / Abstract: The aim of this study was to verify the influence of resin opacity, light curing units (halogen light X blue LED) and topic application of 1.23% acidulated phosphate fluoride (APF) on the resin hardness. The composite resin Esthet-X (Dentsply), shade A2 and A2-O was put in stainless steel molds of 5 mm diameter and 2 mm depth, and cured with a halogen light curing unit, XL 3000 (3M) or a blue LED unit, Optilight LD II (Gnatus), for 40s. Four groups with thirty samples were separated and the top and bottom of samples were analyzed. They were stored for 24h and afterwords, built-in acrylic resin. Vickers hardness measurements were made in Vickers Digital Microhardmeter, using 50g load and 30s time. The APF 1.23% was applied for 48 min and a second hardness measurement was done. Statistic test ANOVA and Tukey (5%) demonstrated that top hardness were always higher than bottom. The halogen unit presented higher hardness values (57.61 HV) than LED unit (42.53 HV). Significant differences were found between the hardness values when the opacity was varied, and depth wise the A2-O resin presented the lowest values. The use of 1.23% APF on the resin resulted in the lowest values of hardness. The resin opacity, the light curing unit and the use of 1.23% APF have all influence on the resin hardness. / Mestre

Page generated in 0.0615 seconds