• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 36
  • 15
  • 1
  • 1
  • 1
  • Tagged with
  • 129
  • 52
  • 23
  • 22
  • 17
  • 15
  • 14
  • 14
  • 13
  • 12
  • 12
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliação in vitro e in situ do efeito dos íons ferro na erosão da superfície dentária bovina e humana / In vitro and in situ evaluation of the effect of iron ions on the erosion of bovine and human dental surface

Melissa Thiemi Kato 05 March 2007 (has links)
O objetivo geral deste estudo foi avaliar o efeito do íon ferro na inibição da erosão de dentes bovino e humano provocada por bebidas ácidas, em estudos in vitro e in situ. O estudo foi realizado em três etapas. No 1° subprojeto, foi avaliado, in vitro, o efeito de concentrações crescentes de ferro na dissolução do pó de esmalte bovino, quando adicionado à Coca-Cola® e à Sprite Zero®. A concentração de ferro, para a qual foi observada inibição de perda de fósforo, foi utilizada nos experimentos seguintes. Para se determinar a quantidade de esmalte dissolvido foi analisado o fósforo por método colorimétrico. Os dados foram analisados por ANOVA e teste de Tukey (p<0,05). No 2º subprojeto (in vitro), blocos de esmalte bovino foram expostos a 4 ciclos de desmineralização em Coca-Cola®, contendo ou não 10 mmol/L de ferro (experimental e controle, respectivamente). Cada ciclo de desmineralização foi seguido por um ciclo de remineralização em saliva artificial. O 3º subprojeto foi constituído por um estudo in situ, cruzado, no qual 10 voluntários utilizaram dispositivos palatinos, contendo 2 blocos de esmalte e 2 de dentina humanos durante 2 fases de 5 dias cada. A diferença entre estas fases foi a adição ou não de ferro a 10 mmol/L ao refrigerante tipo cola, antes da imersão do dispositivo na mesma. Os voluntários imergiram os dispositivos por 5 minutos em 150 mL de Coca-Cola®, contendo ou não ferro, 4 vezes ao dia. O efeito do ferro na inibição da erosão, tanto do 2º como do 3º subprojetos, foi avaliado pela %PDS e análise de desgaste. Os dados foram analisados usando teste t (p<0,05). Resultados: Subprojeto 1- quando ferro a 30 e 60 mmol/L foi adicionado à Coca-Cola®, uma redução na dissolução do pó de esmalte foi observada quando comparado ao controle (11 e 17%, respectivamente), enquanto concentrações menores não tiveram nenhum efeito. Com relação à Sprite Zero®, concentrações de ferro acima de 10 mmol/L não tiveram efeito significativo, enquanto concentrações maiores aumentaram significativamente a dissolução do pó de esmalte. Subprojeto 2- O ferro a 10 mmol/L reduziu significativamente o desgaste, mas aumentou significativamente a %PDS dos blocos de esmalte submetidos à erosão in vitro pela Coca-Cola®. Subprojeto 3- Para o esmalte, houve uma redução significativa no desgaste e uma redução não significativa na %PDS, quando o ferro foi utilizado foi diminuída, embora não significativamente. Para a dentina, houve redução significativa no desgaste e aumento significativo na %PDS quando da utilização do ferro. Assim, concluiu-se que o íon ferro pode reduzir a erosão de dentes bovino e humano provocada por bebidas ácidas, sendo esta ação dependente do tipo de ácido presente na bebida. / The general aim of this study was to evaluate the effect of iron ion on inhibition of the erosion of bovine and human teeth submitted to acidic drinks, using in vitro and in situ protocols. The study was conducted in 3 steps. At the first subproject, it was evaluated, in vitro, the effect of increasing iron concentrations on the dissolution of bovine enamel powder when added to Coke® or Sprite Zero®. The iron concentration for which an inhibition of enamel dissolution was observed was used in the subsequent experiments. The average concentration of phosphate released was analysed spectrophotometrically. Data were analyzed using ANOVA and Tukey?s test (p<0.05). In the second subproject, 24 specimens of bovine enamel were randomly assigned to 2 groups (experimental and control). They were exposed in vitro to 4 cycles of demineralization in Coke® containing or not 10 mmol/L of iron (experimental and control groups, respectively). Each demineralization cycle was followed by a remineralization cycle in artificial saliva. As for the third subproject, in an in situ crossover protocol, 10 volunteers wore palatal devices containing human 2 enamel and 2 dentin blocks during two 5-day crossover phases. The difference between these phases was the addition or not of iron at 10 mmol/L in Coke® before the immersion of the devices. The volunteers immersed the devices for 5 minutes in 150 mL of cola drink, containing or not iron, 4 times per day. The effect of iron on the inhibition of erosion in subprojects 2 and 3 was evaluated by %SMH and wear analysis. Data were analyzed using t test (p<0.05). Results: Subproject 1 - when iron at 30 and 60 mmol/L was added to Coke®, a significant reduction in the dissolution of powdered enamel was observed when compared to control (11 and 17%, respectively), while lowering iron concentrations did not have any effect on enamel powder dissolution. Regarding Sprite Zero®, iron concentrations up to 10 mmol/L had no significant effect, while higher concentrations significantly increased enamel powder dissolution. Subproject 2- Iron at 10 mmol/L significantly reduced the wear, but significantly increased the %SMH of enamel blocks submitted to in vitro erosion by Coke®. Subproject 3- For enamel, when iron was used, a significant reduction in the wear and a non-significant reduction in the %SMH were observed. For dentin, the use of iron significantly reduced the wear but significantly enhanced the %SMH. Hence, we concluded that iron ion may reduce the erosion of bovine and human teeth caused by acidic drinks, depending on the type of acid present in the beverage.
72

Sensibilidade dolorosa e efetividade do clareamento dental de consultório

Bortolatto, Janaína Freitas [UNESP] 22 March 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-03-22Bitstream added on 2014-06-13T19:30:41Z : No. of bitstreams: 1 bortolatto_jf_me_arafo.pdf: 330387 bytes, checksum: ca6d863c0f12ef0d2257d1ee26cbdeb4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Vários aspectos da técnica de clareamento dental de consultório permanecem controversos. Neste trabalho foram estudadas a sensibilidade dolorosa e a efetividade determinadas por diferentes tratamentos clareadores. Participaram deste estudo 60 voluntários de ambos os gêneros, com idades variando de 18 a 25 anos que foram aleatoriamente distribuídos em 3 grupos. GI: peróxido de hidrogênio a 35% sem ativação por luz, GII: o mesmo peróxido ativado por dispositivo de luz conjugada LED/LASER e GIII: gel clareador a 15% contendo nanopartículas de óxido de titânio nitrogenado ativado por luz conjugada LED/LASER. A sensibilidade dos pacientes durante as sessões de clareamento foi avaliada utilizando uma escala VAS modificada. A alteração de cor determinada pelos protocolos de clareamento foi mensurada por espectroscopia de reflectância (Vita Easy Shade®,Vident, Brea, CA, USA). Os valores de ΔL (luminosidade), ΔE (variação de cor) e sensibilidade provocada pelos tratamentos (S) foram analisados por meio do método de equações de estimação generalizadas (GEE), comparações múltiplas ad Hoc de Bonferroni com significância de 5%. No estudo 1, realizado para avaliar a eficiência da utilização da luz conjugada LED/Laser, os voluntários de GI relataram maior freqüência e intensidade de sensibilidade provocada pelo tratamento clareador (37,6 ± 5,9% para GI contra 11,1 ± 3,3% de GII). O clareamento em GII foi mais eficiente que em GI (p>0,05). No estudo 2, a utilização do gel clareador H2O2 a 15% contendo TiO_N resultou em menor freqüência e intensidade de sensibilidade provocada que em GI (37,6 ± 6,1% para GI contra 11,9 ± 5,0% de GII) e maior eficiência de clareamento (p>0,05). Concluiu-se que o método de fototermo catalisação com luz conjugada LED/Laser utilizada em conjunto com agente clareadores... / Several aspects of in-office dental bleaching remain controversial. In this study, we studied the painful sensitivity and effectiveness determined using different bleaching techniques. The study included 60 volunteers of both genres, with ages ranging from 18 to 25 years who were randomly divided into 3 groups. GI: hydrogen peroxide 35% without activation by light, GII: the same peroxide-activated device LED / Laser and GIII: 15% whitening gel containing nanoparticles of titanium oxide nitrogen activated by coupled light LED / Laser. The sensitivity of the patients during the bleaching treatments was evaluated using a modified VAS scale. The color change determined by the protocols of bleaching was measured by reflectance spectroscopy (Vita Easy Shade ®, Seer, Brea, CA, USA). The values of ΔL (brightness), ΔE (color variation) and sensitivity caused by the treatments (S) were analyzed by the method of generalized estimating equations (GEE), multiple comparisons with Bonferroni ad hoc 5% significance. In study 1, conducted to evaluate the efficacy of use of coupled light LED/Laser, GI volunteers reported a higher frequency and intensity of sensitivity caused by bleaching treatment (37.6 ± 5.9% for GI against 11.1 ± 3.3% of GII). The Bleaching was more efficient in GII than GI (p> 0.05). In study 2, the use of gel co 15% H2O2 containing TiO_N resulted in a lower frequency and intensity of sensitivity caused in GI (37.6 ± 6.1% for GI vs. 11.9 ± 5.0% of GII) and greater efficiency of bleaching (p> 0.05). It was concluded that the method of catalyzing photothermo reaction with coupled light LED/Laser used in conjunction with bleaching agent type homogenous advanced oxidation process (POAHo) allows both the reduction of sensitivity caused as time of treatment and the agent of lower concentration reduces sensitivity, increasing safety of tooth whitening, with the same efficiency as the traditional agent
73

Influência do método de preparo cavitário, alta rotação e laser de Er:YAG, sobre a espessura da camada híbrida de diferentes sistemas adesivos, com diferentes filosofias adesivas / Influence of cavity preparation method, high speed turbine and Er:YAG laser, on hybrid layer thickness of different adhesive systems

Marcos de Oliveira Barceleiro 11 October 2006 (has links)
O objetivo deste estudo foi promover uma comparação entre as espessuras de camadas híbridas formadas entre os sistemas adesivos Scotchbond Multi-Uso Plus, Single Bond 2, Prime & Bond 2.1 e Xeno III, e a superfície dentinária, preparada com dois métodos de preparo cavitário, a ponta diamantada montada em turbina de alta rotação, e o laser de Er:YAG, utilizado com dois parâmetros de energia (200 e 400 mJ) e dois parâmetros de freqüência (4 e 6 Hz). Para a realização deste experimento, foram realizados tratamentos superficiais com os dois métodos descritos em fragmentos de dentina superficial aplainada, retirados de vinte terceiros molares humanos recém-extraídos, seguido de preparo da dentina com os sistemas adesivos. Após a aplicação e fotoativação de uma camada de compósito sobre a dentina preparada, os corpos de prova foram cortados, polidos e preparados para visualização em MEV, meio pelo qual foram realizadas cinco medidas da espessura da camada híbrida formada em cada corpo de prova. Os resultados obtidos foram tratados estatisticamente por ANOVA e teste de Student-Newnan-Keuls, em um nível de significância de 95%, e por Kruskal Wallis e Mann Whitney, também em um nível de significância de 95%, através do programa SPSS for Windows release 5.0. A análise foi realizada levando-se em consideração dois fatores de estudo, a presença ou não de camada híbrida e a espessura da camada híbrida. Em relação ao fator espessura da camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por ANOVA e Student-Newman-Keuls levou a formação de quatro grupos homogêneos, sendo Grupo I (ponta diamantada) > Grupo II (Laser 200 mJ / 4 Hz) = Grupo III (Laser 200 mJ / 6 Hz) > Grupo IV (Laser 400 mJ / 4 Hz) > Grupo V (Laser 400 mJ / 6 Hz). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Em relação ao fator presença de camada híbrida, quando se avaliou o tipo de preparo realizado, a análise estatística por Kruskal Wallis e Mann Whitney levou a formação de três grupos homogêneos (Grupo I _ Grupo II = Grupo III = Grupo IV _ Grupo V). Quando se avaliou o tipo de sistema adesivo utilizado, não se encontrou diferença estatisticamente significante. Quando se realizou o cruzamento tipo de preparo x sistema adesivo, a análise estatística mostrou a formação de sete grupos distintos. Pela análise dos resultados obtidos neste estudo in vitro, foi possível concluir que em dentina preparada com ponta diamantada em alta rotação, os quatro sistemas adesivos testados formaram camadas híbridas de formato regular e presentes de forma constante, com espessura média de 2,90 1,71 m, e em dentina preparada com laser de Er:YAG, os quatro sistemas adesivos testados formaram camadas híbridas de formato irregular e presentes de forma intermitente, com espessura média variando entre 0,41 1,00 m e 2,06 2,49 m. Além disso, concluiu-se que o laser de Er:YAG com os parâmetros testados influencia negativamente a formação da camada híbrida, e que os métodos de preparo cavitário influenciam na espessura da camada híbrida. / The objective of this study was to compare the thickness of the hybrid layer formed using Scotchbond Multipurpose Plus, Single Bond 2, Prime & Bond 2.1 and Xeno III on dentine surface, prepared with a diamond bur in a high speed handpiece, or prepared with an Er:YAG laser, used with two parameters of pulse energy (200 and 400 mJ) and two parameters of frequency (4 and 6 Hz). Flat dentine surfaces obtained from twenty third molars human teeth were treated with the two methods, and then were prepared with the dentine adhesive systems, according to manufacturers instructions. After a layer of composite was applied, specimens were sectioned, flattened, polished and prepared for Scanning Electronic Microscopy observation. Five different measurements of hybrid layer thickness were obtained along the bonded surface in each specimen. Results were statistically analyzed using analysis of variance and Student-Newman-Keuls tests (p &#8804; 0.05), and using Kruskal Wallis and Mann Whitney tests (p &#8804; 0.05). The statistical analysis was made considering two observations parameters, the presence of the hybrid layer, and its thickness. When analyzing the hybrid layer thickness, and comparing the cavity preparation method, four groups were formed, Group I (diamond bur) > Group II (Laser 200 mJ / 4 Hz) = Group III (Laser 200 mJ / 6 Hz) > Group IV (Laser 400 mJ / 4 Hz) > Group V (Laser 400 mJ / 6 Hz). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the presence of hybrid layer, and comparing the cavity preparation method, three groups were formed (Group I &#8800; Group II = Group III = Group IV &#8800; Group V). When comparing the dentine adhesive systems, it was not found any statistically significant difference. When analyzing the hybrid layer thickness, and comparing the cavity preparation method x the dentine adhesive systems, it was found seven different groups. These results showed that the four tested dentine adhesive systems produce a 2.90 1.71 &#956;m hybrid layer in dentine prepared with diamond bur. This hybrid layer was regular and constantly found. In the laser groups, the dentine adhesive systems produced hybrid layers ranging from 0.41 1.00 &#956;m to 2.06 2.49 &#956;m, which were very irregular and were not found constantly. It was also concluded that Er:YAG laser with the parameters used in this experiment, is a negative influence to the hybrid layer formation, and that cavity preparation methods do influence the hybrid layer formation.
74

Análise molecular vibracional da interface adesivo-dentina após aplicação de múltiplas camadas de sistemas adesivos convencionais de dois passos / Dentine-adhesive molecular vibrational analysis of multi-layer applications of one step etch and rinse adhesive systems

Marcelo José Braga Pinhão 28 February 2008 (has links)
O propósito do presente estudo foi analisar o efeito da aplicação de múltiplas camadas consecutivas de dois sistemas adesivos convencionais de dois passos na difusão resinosa e padrão de distribuição dos componentes monoméricos resinosos. Dezesseis terceiros molares humanos hígidos foram tratados com os sistemas adesivos convencionais de dois passos de acordo com as instruções dos fabricantes ou com aplicações em múltiplas camadas consecutivas. Os espécimes foram seccionados paralelamente aos túbulos dentinários e as superfícies submetidas ao polimento com lixas 600, 1200, 1800, 2000 e 4000. Os espectros Raman foram coletados ao longo de uma linha perpendicular a interface adesivo-resina em intervalos de 1 ou 2 m. As medidas de difusão da resina adesiva e distribuição dos componentes monomériccos foram avaliadas pelos picos Raman de 1113 cm-1, 1609 cm-1 e 1454 cm-1. O gradiente de desmineralização usado na determinação da região de hibridização foi avaliado pelo pico de 960 cm-1 da apatita. De acordo com os resultados obtidos, a aplicação de múltiplas camadas apresentou uma tendência de homogeneização dos componentes poliméricos, dependente da composição química da resina adesiva. / The present study analyzed the effect of multiple consecutive adhesive coatings on the pattern of resin diffusion and distribution of monomer components through demineralised dentin after application of two total-etch adhesives. Resin bonded dentin specimens were prepared using two total-etch adhesives (Prime&Bond NT2.1 and Adper Single Bond). The specimens were sectioned parallel to dentinal tubules and the surfaces were polished using 600, 1200, 1800, 2000 and 4000 silicon-carbide papers. Raman spectra were recorded along a line perpendicular to the dentin-resin interface in steps of 1 or 2 m. The measurements of resin diffusion and distribution of monomer components were made on a relative basis by comparing the bands 1113, 1609 and 1454 cm-1. The gradient of dentin demineralization, designed to 960 cm-1, was used to determine the extent of hybridization. From the results of the present study the application of multiple coatings of adhesive showed a trend to produce a homogeneous hybrid layer.
75

Avaliação através da microscopia eletrônica de varredura e transmissão da dentina bovina após uso de diferentes protocolos de irrigação

Wagner, Márcia Helena January 2014 (has links)
O objetivo deste estudo foi analisar, através de microscopia eletrônica de varredura (MEV) e transmissão (MET), a ultraestrutura dentinária após a utilização de diferentes protocolos de irrigação. Trinta e nove incisivos inferiores bovinos após ter suas coroas amputadas e polpas dentárias removidas, foram divididos randomicamente em 13 grupos (n=3). Nos grupos 2 ao 13 as paredes dos canais foram regularizadas com brocas Gates-Glidden e padronizado o diâmetro apical no tamanho correspondente a uma lima K #70. Todas as raízes foram clivadas longitudinalmente em duas metades. As seis hemirraízes pertencentes ao grupo controle foram imersas em água destilada, em cuba de ultrassom, acionada durante dois intervalos de 5 minutos. As demais foram imersas em EDTA 17%, ultrassonificadas por 5 minutos e em seguida, por mais 5 minutos, imersas em água destilada, para padronização das amostras. As hemirraízes, reunidas ao respectivo par, receberam o protocolo de irrigação específico para cada grupo: Grupo 1 (G1): água destilada (controle); G2: soro; G3: soro e EDTA 17%; G4: soro + AUP; G5: soro + AUP + EDTA; G6: NaOCl 2,5%; G7: NaOCl + EDTA; G8: NaOCl + AUP; G9: NaOCl + AUP + EDTA; G10: CHX 2%; G11: CHX + EDTA; G12: CHX + AUP; G13: CHX + AUP + EDTA. Uma hemirraiz de cada espécime foi preparada e avaliada através de MEV e, uma de cada grupo, através de MET. Os resultados da análise descritiva através da MET evidenciaram a degeneração na estrutura orgânica dentinária, caracterizada pelo afilamento das fitas de colágeno, causada pelo NaOCl, potencializado pelo EDTA e/ou AUP. A análise através da MEV mostrou que o NaOCl com AUP provocou erosão da dentina peritubular significativamente maior que todos os demais grupos (P<0,05), seguido do NaOCl com EDTA e NaOCl com EDTA e AUP, nesses três grupos também ocorreu erosão na dentina intertubular. O NaOCl 2,5% favoreceu melhor limpeza, causou erosão da dentina peri e intertubular e promoveu alterações ultraestrturais no colágeno dentinário, potencializado pelo EDTA e/ou AUP. / The aim of this study was to analyze, by scanning, and transmission electron microscopy the dentin ultrastructure after using different irrigation protocols. Thirty-nine bovine incisors after amputated their dental crowns and pulp removed, were randomly divided into 13 groups (n = 3). In groups 2-13 the root canal walls were regularized with Gates-Glidden drills and standardized apical diameter up to a size #70 K-file. All roots were split longitudinally into two halves. The six halves belonging to the control group were immersed in distilled water in the ultrasonic tank, actived during two intervals of 5 minutes. The others halves were immersed in 17% EDTA, actived for 5 minutes and then, for 5 minutes, immersed in distilled water for samples standardization. After the halves were reassembled, they received the irrigation protocol specific for each group: G1, distilled water (control); G2, 0.9% saline; G3, saline + 17% EDTA; G4, saline + PUI; G5, saline + PUI + EDTA; G6, 2.5% NaOCl; G7, NaOCl + EDTA; G8, NaOCl + PUI; G9, NaOCl + PUI + EDTA; G10, 2% CHX; G11, CHX + EDTA; G12, CHX + PUI; G13, CHX + EDTA + PUI. One half of each specimen was prepared and evaluated by SEM, and one of each group, by TEM. The results of the descriptive analysis by TEM showed changes in the dentin organic ultrastructure, characterized by thinning of the collagen fibrils, caused by 2,5% NaOCl, potentiated by 17% EDTA and/or PUI. The analysis by SEM showed that the PUI with NaOCl caused peritubular dentin erosion significantly higher than all other groups (P <0.05), followed by NaOCl with EDTA and by NaOCl with EDTA and PUI, in these three groups also occurred intertubular dentine erosion. The 2,5% NaOCl favored better cleaning, caused erosion of the peritubular and intertubular dentin and promoted ultrastructural alterations in the dentin collagen which were potentilaized by EDTA and/or PUI.
76

Estudo da viabilidade bacteriana em dentina cariada selada / Study of bacterial viability in carious dentin sealed

Firmino, Luciana Bitello January 2011 (has links)
Na literatura não existe consenso em relação à quantidade de dentina cariada que deve ser removida durante o preparo cavitário. Desta forma, este estudo teve como objetivo comparar os microorganismos remanescentes após a remoção total de tecido cariado e selamento e a remoção parcial de tecido cariado e selamento. Molares permanentes com lesões de cárie primárias ativas localizadas no terço médio da dentina e apresentando polpa vital foram divididos aleatoriamente em dois grupos: grupo teste - remoção parcial de tecido cariado (n=18), ou grupo de controle - remoção total de tecido cariado (tratamento restaurador convencional) (n=18). Os desfechos analisados foram a quantificação microbiana e a freqüência de isolamento microbiano. Amostras de dentina foram obtidas com duas brocas de baixa rotação estéreis n º 4, após a remoção da cárie e após 3 meses de proteção com cimento de hidróxido de cálcio e selamento das cavidades com cimento de ionômero de vidro. As amostras foram armazenadas em um recipiente estéril contendo 1,2 ml de RTF e submetidas a diluições decimais. Análises microbiológicas foram realizadas para Streptococcus spp., estreptococos do grupo mutans, Lactobacillus spp. e contagem total de anaeróbios.Antes do selamento, uma maior contagem de microrganismos foi detectada no grupo teste, em comparação ao grupo controle. No grupo de teste, uma redução significativa foi encontrada, após o selamento, na contagem de anaeróbios totais, Streptococcus spp. e Lactobacillus spp. Após 3 meses de selamento, não foi detectada diferença no crescimento microbiano entre os grupos para qualquer um dos microrganismos estudados. Portanto, a semelhança observada entre a infecção microbiana após a escavação convencional e remoção parcial de tecido cariado sugere que não há necessidade de realizar a remoção total do tecido cariado baseada em critérios clínicos convencionais de dureza. / In the literature there is no consensus on the amount of carious dentin to be removed during the cavity preparation. Thus, this study aimed to compare the remaining microorganisms after complete caries removal and sealing to partial caries removal and sealing. Permanent molars with active primary carious lesions located in the middle third of dentin and vital pulp were randomly divided into two groups of 18: test group - partial caries removal, or control group – complete caries removal (conventional restorative treatment). The outcomes analyzed were microbial quantification and frequency of microbial isolation. Dentin samples were obtained with two sterile n° 4 round burs after caries removal and after 3 months of protection with calcium hydroxide cement and sealing of the cavities with glass ionomer cement. The samples were stored in a sterile container with 1.2 ml of RTF and submitted to decimal dilutions. Microbiological analyses were performed to the Streptococcus spp., Mutans streptococci, Lactobacillus spp. and total anaerobes counts. Before sealing, a higher microorganism counts were detected in the test group compared to the control group. In the test group, significant reduction was found after sealing in the total anaerobes count, Streptococcus spp. and Lactobacillus spp. After 3 months of sealing, no difference was detected in microbial growth between groups for any of the microorganisms studied. Therefore, the observed similarity between the microbial infection after conventional excavation and partial caries removal suggests that there is no need to perform complete caries removal based on conventional clinical criteria of hardness.
77

Effect of frequency of intake and amount of fluoride in milk on enamel and dentine caries: in situ study / Efeito da frequência de ingestão e quantidade de fluoreto no leite sobre cárie de esmalte e dentina: estudo in situ

Luiza de Paula Silva Cassiano 12 September 2014 (has links)
This study analysed the effect of frequency of intake and amount of fluoride in milk on the remineralisation of artificial enamel and dentine caries lesions in situ. Predemineralised bovine enamel and dentine slabs were randomly allocated to 5 in situ phases. Twenty-three subjects wore removable appliances with 2 enamel and 2 dentine slabs for 7 days each phase (separated by a 7-day washout period), following a crossover double-blind protocol. In each phase, treatment was performed with milk containing 2.5 ppm fluoride (F) everyday (T1), 2.5 ppm F every other day (T2), 5.0 ppm F every day (T3), 5.0 ppm F every other day (T4) or no treatment (control; T5). The subjects were instructed to immerse the appliance in 100 ml of milk for 5 minutes and then drank 200 ml of the respective milk. The enamel alterations were quantified by surface hardness (%SHR) and transversal microradiography (TMR, Z) and dentine by TMR only. Data were analysed by repeated-measures ANOVA/Tukey´s tests (p<0.05). For enamel, the highest %SHR was found for groups treated with fluoridated milk every day compared to control, without significant differences between T1 and T3. All groups showed positive values of Z, except for T4; significant differences were seen between T1/T3 and T4. For dentine, the only group that presented remineralisation was T2. Fluoridated milk every day seems to have better remineralising effect on enamel than its use every other day, but no dose-response effect was seen. Dentine, however, does not seem to benefit from every day use of fluoridated milk. / O presente estudo teve como objetivo analisar o efeito do leite fluoretado com concentrações e frequências diferentes na remineralização de lesões de cárie de esmalte e dentina produzidas artificialmente in situ. Blocos de esmalte e dentina bovino previamente desmineralizados foram distribuídos aleatoriamente em cinco grupos. Vinte e três indivíduos usaram aparelhos removíveis contendo 2 blocos de esmalte e 2 blocos de dentina por 7 dias em cada fase (separadas por um período de washout de 7 dias), seguindo um protocolo duplo-cego, cruzado. Em cada fase, o tratamento realizado foi com leite contendo 2,5 ppm de flúor (F), todos os dias (T1), 2,5 ppm de F em dias alternados (T2), 5,0 ppm F todos os dias (T3), 5,0 ppm F em dias alternados (T4) ou sem tratamento (T5). Os sujeitos foram instruídos a mergulhar o aparelho em 100 ml de leite por 5 minutos e, em seguida, beberam 200 ml do mesmo leite. As alterações no esmalte foram quantificadas por dureza superficial e microradiografia transversal (TMR), e dentina apenas por microradiografia transversal. Os dados foram analisados por medidas repetidas ANOVA / Tukey (p <0,05). Para o esmalte, o mais alto valor de porcentagem de recuperação de dureza superficial foi encontrado para os grupos tratados com leite fluoretado todos os dias em relação ao controle, sem diferenças significativas entre T1 e T3. Todos os grupos apresentaram valores positivos de Z, com exceção de T4; foram observadas diferenças significativas entre T1/T3 e T4. Para a dentina, o único grupo que apresentou remineralização foi T2. O leite fluoretado todos os dias parece ter melhor efeito remineralizante sobre o esmalte do que seu uso em dias intercalados, mas nenhum efeito dose-resposta foi visto. A dentina, no entanto, não parece se beneficiar do uso diário de leite fluoretado.
78

Avaliação da estabilidade da aplicação de um híbrido experimental em diferentes concentrações sobre a dentina sensível - in vitro / Evaluation of the stability of application of an experimental hybrid on the sensitive dentin in differents concentrations - in vitro

Tatiane Alexandre de Oliveira 08 November 2016 (has links)
O objetivo deste estudo foi avaliar, in vitro, quantitativamente e qualitativamente, a estabilidade de um híbrido experimental em duas concentrações diferentes (concentrado e diluído) aplicado sobre a simulação de uma dentina sensível. Dentes molares humanos foram selecionados e tiveram suas coroas seccionadas abaixo do sulco oclusal de forma a obter espécimes de discos de dentina que foram planificados e polidos até atingirem a espessura de 1,0 milímetro. Os espécimes foram divididos em 4 grupos (n=9) de acordo com os tratamentos de superfície propostos: saliva artificial (SAL), adesivo dentinário autocondicionante (AD), híbrido experimental concentrado (TC) e híbrido experimental diluído na proporção de 1:3 (TD). Dois métodos foram empregados para avaliar a estabilidade: condutância hidráulica (permeabilidade dentinária) e microscopia eletrônica de varredura. Foi realizada a leitura da permeabilidade dentinária em 6 tempos experimentais: Mínima (sem tratamento), Máxima (com túbulos abertos), Tratamento (após aplicação dos respectivos tratamentos), Erosão (após 5 minutos de imersão em ácido cítrico 0,05M pH 3,8), Escovação (após escovação de 3900 ciclos) e Erosão Pós (repetição da erosão após o processo de escovação). A microscopia eletrônica de varredura foi realizada em espécimes de dentina com área central de aplicação dos tratamentos e tecido natural nas laterais para evidenciar as características da película aplicada. As leituras foram feitas após a aplicação dos tratamentos, após a erosão, após a escovação e após a erosão pós escovação, para todos os 4 tratamentos propostos. O teste de análise de variância (ANOVA) de Medidas Repetidas com 2 fatores de variação foi aplicado juntamente com o teste de comparações múltiplas pareadas (Tukey). Para permeabilidade dentinária todos os tratamentos reduziram a condutância hidráulica (Lp) em relação à Máxima. TC e TD apresentaram os menores valores (24% e 15%) respectivamente. O TD continuou apresentando valores semelhantes estatisticamente após a Erosão (36%), sendo estatisticamente semelhante ao TC (55%).. No tempo Escovação o TD apresentou Lp estatisticamente semelhante aos tempos Tratamento e Erosão. Todos os grupos apresentaram-se estatisticamente semelhantes entre os tratamentos nos tempos Escovação e Erosão Pós. A análise das MEVs evidencia túbulos dentinários com conteúdo no seu interior nos grupos TC e TD, mantendo-se durante todos os tempos experimentais. O AD apresentou uma película evidente, que começou a se destacar e exibir falhas a partir do tempo Erosão. Conclui-se que o TD apresentou o melhor comportamento sendo capaz de diminuir a permeabilidade dentinária, formando uma película fina, transparente, imperceptível, capaz de vedar (totalmente ou parcialmente) e penetrar dentro dos túbulos dentinários, resistindo aos desafios erosivos e abrasivos. / The aim of this study was to evaluate, in vitro, quantitatively and qualitatively, the stability of an experimental hybrid with two different concentrations (concentrated and diluted) applied at a simulation of a sensitive dentin. Human molar teeth were selected and their crowns were sectioned below the occlusal groove in order to obtain specimens of dentine disks that were ground flat and polished to achieve a thickness of 1.0 millimeter. The specimens were divided into 4 groups (n = 9) in accordance with proposed surface treatments: Artificial saliva (SAL) dentinal self-etching adhesive (AD), concentrated experimental hybrid (TC) and experimental hybrid diluted in the ratio 1: 3 (TD). Two methods were used to assess the stability: hydraulic conductance (dentin permeability) and scanning electron microscopy. The dentin permeability in 6 experimental times was carried out: Minimum (no treatment), Maximum (with open tubules), treatment (after application of their treatments), erosion (after 5 minutes of immersion in citric acid 0.05M pH 3, 8), brushing (brushing after 3900 cycles) and Post erosion (erosion was repeated after brushing). The scanning electron microscopy was performed on dentin specimens with a central area of application of treatments and natural tissues on the sides to show the film characteristics applied. Readings were made after application of treatments, after erosion, after brushing and after erosion after brushing, for all 4 treatments proposed. The analysis of variance (ANOVA) for repeated measures with two variation factors was applied with the multiple comparisons paired test (Tukey). For dentin all treatments reduced hydraulic conductance (Lp) in relation to Maximum. TC and TD showed the lowest values (24% and 15%) respectively. The TD continued to show statistically similar values after erosion (36%), being statistically similar to TC (55%). In brushing time the TD Lp was statistically similar to Treatment and erosion times. All groups were statistically similar between treatments in brushing and Post Erosion times. The analysis of SEM shows dentinal tubules with content inside on the TC and TD groups, remaining during all experimental period. AD presented a clear film, which began to stand out and show failure from erosion time. It follows that the TD had better behavior being able to decrease permeability of dentin by forming a thin film transparent, imperceptible, capable of sealing (fully or partially) and penetrate within the dentine tubules, resisting the erosive and abrasive challenges.
79

"Contribuição para o estudo da propagação da luz atráves do esmalte e da dentina humanos" / A Contribution for the Study of the Propagation of Light through the Human Enamel and Dentine

Washington Steagall Junior 01 June 2005 (has links)
Este trabalho estuda a propagação da luz no esmalte e dentina humanos, através da transmitância direta e absorbância no intervalo de comprimento de onda de 200 a 3200nm, e através da transmitância total no intervalo de onda de 380 a 760nm. Foram utilizadas secções de 30 molares humanos íntegros, que foram seccionados nos sentidos VL (vestíbulo – Lingual), MD (mésio distal) e OC (ocluso cervical). As espessuras utilizadas foram de 0,5mm e 0,25mm. Foram agrupados 5 dentes para cada sentido para cada espessura. Esmalte e dentina estavam presentes de maneira simultânea na mesma amostra. A absorbância foi calculada, a partir dos espectros de transmitância direta, aplicando-se a Lei e Beer-Lambert. Os espectros de transmitância total foram obtidos no espectro visível, e comparados, em média, com os espectros de transmitância direta no mesmo intervalo, para obter a energia difusa das amostras. Os espectros UV (Ultravioleta), VIS (Visível) e IV (Infravermelho), foram tratados separadamente para cada tecido e espessura. No infravermelho foram identificados os picos de transmitância e absorbância para ambos os tecidos. Os valores de transmitância e absorbância para cada faixa espectral foram tratados pela ANOVA, e os grupos comparados pelo teste de intervalo de confiança (95%). Os resultados mostraram que, as propriedades ópticas do esmalte e dentina diferem no que diz respeito as 3 faixas espectrais testadas. Os resultados também mostram que as propriedades ópticas são dependentes da espessura e do sentido de seccionamento dos dentes. A pesar das diferenças apresentadas entre os espectros, as curvas espectrais mostraram um padrão semelhante para todas as amostras de dentina e de esmalte, independente da espessura. Este comportamento possibilitou a identificação de picos comuns nos espectros estudados. / This research studies the propagation of light in the human enamel and dentine, through direct transmittance and absorbance in the 200 to 3200nm wavelength interval, and through total transmittance in the 380 to 760nm wavelength interval. The study employed sections of 30 human integral molars, which were sectioned in the VL directions (vestibule – Lingual), MD (mesio distal), and OC (occlusion cervical). The thicknesses used were from 0.5mm to 0.25mm. Five teeth were grouped in each direction for each thickness. Enamel and dentine were simultaneously present in the same sample. Absorbance was calculated from the direct transmittance specters, applying the Beer-Lambert Law. Total transmittance specters were obtained in the visible specter, and compared, on average, with the Total transmittance specters in the same interval, to obtain the diffuse energy of the samples. UV (Ultraviolet), VIS (Visible), and IV (Infrared) specters, were treated separately for each tissue and thickness. In infrared, the transmittance and absorbance peaks were identified for both tissues. The transmittance and absorbance spectral range were treated by ANOVA, and the groups compared by the confidence interval test (95%). The results showed that the optical properties of the enamel and dentine differ with regard to the three tested spectral ranges. The results also showed that the optical properties are dependent on the thickness and the direction of the sectioning of the teeth. Despite the differences found between the specters, the special curves showed a similar pattern for all samples of dentine and enamel, independently of the thickness. This behavior allowed the identification of common peaks in the specters under study.
80

Avaliação através da microscopia eletrônica de varredura e transmissão da dentina bovina após uso de diferentes protocolos de irrigação

Wagner, Márcia Helena January 2014 (has links)
O objetivo deste estudo foi analisar, através de microscopia eletrônica de varredura (MEV) e transmissão (MET), a ultraestrutura dentinária após a utilização de diferentes protocolos de irrigação. Trinta e nove incisivos inferiores bovinos após ter suas coroas amputadas e polpas dentárias removidas, foram divididos randomicamente em 13 grupos (n=3). Nos grupos 2 ao 13 as paredes dos canais foram regularizadas com brocas Gates-Glidden e padronizado o diâmetro apical no tamanho correspondente a uma lima K #70. Todas as raízes foram clivadas longitudinalmente em duas metades. As seis hemirraízes pertencentes ao grupo controle foram imersas em água destilada, em cuba de ultrassom, acionada durante dois intervalos de 5 minutos. As demais foram imersas em EDTA 17%, ultrassonificadas por 5 minutos e em seguida, por mais 5 minutos, imersas em água destilada, para padronização das amostras. As hemirraízes, reunidas ao respectivo par, receberam o protocolo de irrigação específico para cada grupo: Grupo 1 (G1): água destilada (controle); G2: soro; G3: soro e EDTA 17%; G4: soro + AUP; G5: soro + AUP + EDTA; G6: NaOCl 2,5%; G7: NaOCl + EDTA; G8: NaOCl + AUP; G9: NaOCl + AUP + EDTA; G10: CHX 2%; G11: CHX + EDTA; G12: CHX + AUP; G13: CHX + AUP + EDTA. Uma hemirraiz de cada espécime foi preparada e avaliada através de MEV e, uma de cada grupo, através de MET. Os resultados da análise descritiva através da MET evidenciaram a degeneração na estrutura orgânica dentinária, caracterizada pelo afilamento das fitas de colágeno, causada pelo NaOCl, potencializado pelo EDTA e/ou AUP. A análise através da MEV mostrou que o NaOCl com AUP provocou erosão da dentina peritubular significativamente maior que todos os demais grupos (P<0,05), seguido do NaOCl com EDTA e NaOCl com EDTA e AUP, nesses três grupos também ocorreu erosão na dentina intertubular. O NaOCl 2,5% favoreceu melhor limpeza, causou erosão da dentina peri e intertubular e promoveu alterações ultraestrturais no colágeno dentinário, potencializado pelo EDTA e/ou AUP. / The aim of this study was to analyze, by scanning, and transmission electron microscopy the dentin ultrastructure after using different irrigation protocols. Thirty-nine bovine incisors after amputated their dental crowns and pulp removed, were randomly divided into 13 groups (n = 3). In groups 2-13 the root canal walls were regularized with Gates-Glidden drills and standardized apical diameter up to a size #70 K-file. All roots were split longitudinally into two halves. The six halves belonging to the control group were immersed in distilled water in the ultrasonic tank, actived during two intervals of 5 minutes. The others halves were immersed in 17% EDTA, actived for 5 minutes and then, for 5 minutes, immersed in distilled water for samples standardization. After the halves were reassembled, they received the irrigation protocol specific for each group: G1, distilled water (control); G2, 0.9% saline; G3, saline + 17% EDTA; G4, saline + PUI; G5, saline + PUI + EDTA; G6, 2.5% NaOCl; G7, NaOCl + EDTA; G8, NaOCl + PUI; G9, NaOCl + PUI + EDTA; G10, 2% CHX; G11, CHX + EDTA; G12, CHX + PUI; G13, CHX + EDTA + PUI. One half of each specimen was prepared and evaluated by SEM, and one of each group, by TEM. The results of the descriptive analysis by TEM showed changes in the dentin organic ultrastructure, characterized by thinning of the collagen fibrils, caused by 2,5% NaOCl, potentiated by 17% EDTA and/or PUI. The analysis by SEM showed that the PUI with NaOCl caused peritubular dentin erosion significantly higher than all other groups (P <0.05), followed by NaOCl with EDTA and by NaOCl with EDTA and PUI, in these three groups also occurred intertubular dentine erosion. The 2,5% NaOCl favored better cleaning, caused erosion of the peritubular and intertubular dentin and promoted ultrastructural alterations in the dentin collagen which were potentilaized by EDTA and/or PUI.

Page generated in 0.0327 seconds