• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

AVALIAÇÃO DA CAPACIDADE DE POLIMERIZAÇÃO E ELEVAÇÃO DE TEMPERATURA PRODUZIDA POR APARELHOS FOTOPOLIMERIZADORES / Curing efficiency and temperature increasement produced by photo-activation devices

Godoy, Eloisa de Paula 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1 EloisaPaula.pdf: 3565954 bytes, checksum: a85195d4f7c3955efe156f512ceaeccf (MD5) Previous issue date: 2008-02-26 / This study evaluated the curing efficiency and the temperature increasement produced by curing units during the photo-activation of the composite, Filtek™Z250 (3M ESPE) and Filtek™Z350 (3M ESPE). At the same time, the emission spectrum and power of the curing units were tested using the spectrometer USB2000 (Ocean Optics) and the Power Meter (Ophir). The light intensity was determined by the reason between power and active top light area of each unit. The curing units used were a halogen lamp Optilux 401 (Demetron) and three light emitting diode devices (LED), LEDemetron I (Kerr), Bluephase (Ivoclar Vivadent) and Elipar Freelight (3M ESPE), with light intensity of 661 mW/cm2, 627 mW/cm2, 1229 mW/cm2 and 330 mW/cm2, respectively. The curing efficiency was evaluated by Vickers hardness, determined on bottom surface the specimens prepared in steal mold, which it was filled with the selected composite, and stored during a period of 24 hours. Using a thermocouple type-K, placed under a dentin disk with 0,5 mm thickness, it was observed The temperature increasement produced by the four devices was measured during the photo-activation of the adhesive system and of an increment of 2 mm of thickness of composite, which were activated for 20 and 40 seconds, respectively. The results of Vickers hardness and of temperature increasement were submitted to the statistical analysis ANOVA 2 way and post test Bonferroni with 5% significance. For the composite Filtek™Z250 (3M ESPE) the four units curing devices assessed did not present statistical differences in the superficial hardness. For the composite Filtek™Z350 (3M ESPE), the unit curing Elipar Freelight (3M ESPE) produced statistical lower hardness (p < 0,05), whereas it has not statistical differences in hardness among the units curing devices. The composite Filtek™Z250 (3M ESPE) presented higher hardness than resin Filtek™Z350 (3M ESPE) (p <0,05). The unit curing light emitting diode Bluephase (Ivoclar Vivadent) and the unit curing of halogen lamp Optilux 401 (Demetron) emitted the same temperature increasement statistically, reaching (17,6°C), duri ng the photo-activation of the adhesive system. The lower value of temperature increase was registered for the unit curing Elipar Freelight (3M ESPE) in the adhesive system (7,2°C) (p < 0,001) and in the composite (3,1°C) (p < 0,05). Statistically, th e temperature increasement registered during the activation of the composite was lower than the temperature increasement registered during the activation in the adhesive system (p < 0,001). / Este estudo avaliou a capacidade de polimerização e a elevação de temperatura produzida por aparelhos fotopolimerizadores na polimerização das resinas compostas, Filtek™Z250 (3M ESPE) e Filtek™Z350 (3M ESPE). Paralelamente foi determinado o comprimento de onda e a potência dos aparelhos, utilizando-se um espectrômentro USB2000 (Ocean Optics) e um Power Meter (Ophir). A intensidade de luz foi obtida pela razão entre potência e área da ponta ativa de cada aparelho. Foram testados um aparelho fotopolimerizador de lâmpada halógena Optilux 401 (Demetron) e três aparelhos à base de LEDs: LEDemetron I (Kerr), Bluephase (Ivoclar Vivadent) e Elipar Freelight (3M ESPE), que apresentaram intensidades de luz de 661 mW/cm2, 627 mW/cm2, 1229 mW/cm2 e 330 mW/cm2, respectivamente. A capacidade de polimerização foi registrada através do teste de microdureza Vickers, avaliando a superfície de base de corpos-de-prova confeccionados em matrizes metálicas, nas quais foram inseridas as resinas compostas selecionadas, e armazenados durante 24 horas. Utilizando-se de um termopar tipo-K, posicionado sob um disco de dentina de 0,5 mm de espessura verificou-se a elevação de temperatura produzida pelos 4 aparelhos durante a fotopolimerização do sistema adesivo e de um incremento de 2 mm de espessura de resina composta, fotopolimerizados por 20 e 40 segundos, respectivamente. Os resultados de microdureza superficial e de elevação de temperatura foram submetidos à análise estatística ANOVA 2 critérios e pós teste de Bonferroni com 5% de significância. Para a resina composta Filtek™Z250 (3M ESPE), os quatro aparelhos avaliados não apresentaram diferenças estatísticas na microdureza superficial. Para a resina composta Filtek™Z350 (3M ESPE), o aparelho Elipar Freelight (3M ESPE) apresentou os menores valores de microdureza superficial (p<0,05), não havendo diferença estatística entre os demais aparelhos. A resina composta Filtek™Z250 (3M ESPE) apresentou maiores valores de microdureza Vickers do que a resina Filtek™Z350 (3M ESPE) (p<0,05). O aparelho à base de LED Bluephase (Ivoclar Vivadent) emitiu estatisticamente a mesma elevação de temperatura que o aparelho de lâmpada halógena Optilux 401 (Demetron) (17,6°C) durante a polimerização do sistema adesivo. O menor valor de elevação de temperatura foi registrado para o aparelho Elipar Freelight (3M ESPE), tanto no sistema adesivo (7,2°C) (p<0,001) como na resina composta (3,1°C) (p<0,05). As elevaç ões de temperatura registradas durante a polimerização das resinas compostas foram estatisticamente menores que as elevações de temperatura registradas durante a polimerização no sistema adesivo (p<0,001).
2

Avaliação da microdureza de resina composta polimerizada com fontes de luz halógena e LED, em função da densidade de energia luminosa irradiada / Knoop hardness analisys of a resin composite activated by halogen lamp and LED, varying the luminous density

Pereira, Rosana Aparecida 08 July 2009 (has links)
No presente estudo, avaliou-se a microdureza da resina composta Z250 (3M ESPE), quando ativada em diferentes tempos (s), diferentes densidades de potência (mW/cm²), em relação à quantidade de energia irradiada (8, 12 e 16 J/cm²), com a finalidade de estabelecer uma densidade de energia luminosa mínima capaz de polimerizar adequadamente os compósitos. Foi utilizado um aparelho com fonte de luz halógena Degulux-Degussa, com 600 mW/cm² e dois aparelhos de fonte de luz LED, Ultraled XP (Dabi-Atlante) com 150 mW/cm² e LED Ultrablue-IS (DMC) com 300 mW/cm² e 600 mW/cm². Duas matrizes bipartidas de PTFE, de 1 e de 2 mm de espessura e um orifício central de 5 mm de diâmetro, foram usadas para confeccionar 60 corpos-de-prova, 5 em cada grupo. As duas partes da matriz foram contidas em um anel metálico com as mesmas espessuras. O material foi inserido na matriz e fotoativado de acordo com os diferentes tempos e a quantidade de densidade de energia luminosa para cada fonte de luz. Para obter os valores de microdureza Knoop, os espécimes foram levados ao microdurômetro Shimadzu HMV-2, com carga estática de 300 g por 5 segundos, para aferir as superfícies exposta (topo) e oposta (base) à fonte de luz, totalizando 120 medições. Os resultados foram submetidos aos testes ANOVA e Tukey, com nível de significância de 5%. Com os dados obtidos foi possível concluir que, com valores a partir de 16 J/cm² e 12 J/cm² de densidade de energia luminosa, espessuras de 2 mm de resina composta podem ser adequadamente polimerizadas utilizando-se fonte de luz halógena (600 mW/cm²) e LED (a partir de 300 mW/cm²) respectivamente. Contudo, estudos clínicos adicionais ainda são necessários para complementar este estudo / At this study it was evaluated the microhardness of the Z250 (3M ESPE) resin composite, when light cured for different periods of time (s), with different power densities (mW/cm²), related to the irradiated luminous energy density (8 J/cm², 12 J/cm² and 16 J/cm²), in order to establish a minimal energy density capable of adequately polymerize the composites. One halogen light curing unit Degulux- Degussa, with 600 mW/cm² of power density and two light-emitting diodes curing units Ultraled XP (Dabi-Atlante) with 150 mW/cm² and LED Ultrablue-IS (DMC) with 300 mW/cm² and 600 mW/cm² were used. Two bipartite PTFE matrices, with 1 and 2 mm of depth and a central orifice of 5 mm diameter, were used to make 60 specimens, 5 per group. The halves of the matrix were positioned inside a brass ring with both depths to prepare the specimens. The resin composite was inserted and light-activated according to the different periods and energy densities of each lightcuring unit. To evaluate Knoop microhardness, specimens were taken to a microdurometer Shimadzu HMV-2 with a static load of 300 g for 5 seconds, evaluating both exposed to light (surface) and opposite to light (base) exposition surfaces, totalizing 120 measurements. Results were submitted to ANOVA and Tukeys test with 5% significance level. Based on the obtained results, it was concluded that, starting from 16 J/cm² and 12 J/cm² of energy luminous density, 2 mm depth resin composite can be adequately polymerized utilizing halogen (600 mW/cm²) and LED ( starting from 300 mW/cm²) curing-units respectively. However, additional clinical studies are necessary to complement this investigation.
3

Avaliação da microdureza de resina composta polimerizada com fontes de luz halógena e LED, em função da densidade de energia luminosa irradiada / Knoop hardness analisys of a resin composite activated by halogen lamp and LED, varying the luminous density

Rosana Aparecida Pereira 08 July 2009 (has links)
No presente estudo, avaliou-se a microdureza da resina composta Z250 (3M ESPE), quando ativada em diferentes tempos (s), diferentes densidades de potência (mW/cm²), em relação à quantidade de energia irradiada (8, 12 e 16 J/cm²), com a finalidade de estabelecer uma densidade de energia luminosa mínima capaz de polimerizar adequadamente os compósitos. Foi utilizado um aparelho com fonte de luz halógena Degulux-Degussa, com 600 mW/cm² e dois aparelhos de fonte de luz LED, Ultraled XP (Dabi-Atlante) com 150 mW/cm² e LED Ultrablue-IS (DMC) com 300 mW/cm² e 600 mW/cm². Duas matrizes bipartidas de PTFE, de 1 e de 2 mm de espessura e um orifício central de 5 mm de diâmetro, foram usadas para confeccionar 60 corpos-de-prova, 5 em cada grupo. As duas partes da matriz foram contidas em um anel metálico com as mesmas espessuras. O material foi inserido na matriz e fotoativado de acordo com os diferentes tempos e a quantidade de densidade de energia luminosa para cada fonte de luz. Para obter os valores de microdureza Knoop, os espécimes foram levados ao microdurômetro Shimadzu HMV-2, com carga estática de 300 g por 5 segundos, para aferir as superfícies exposta (topo) e oposta (base) à fonte de luz, totalizando 120 medições. Os resultados foram submetidos aos testes ANOVA e Tukey, com nível de significância de 5%. Com os dados obtidos foi possível concluir que, com valores a partir de 16 J/cm² e 12 J/cm² de densidade de energia luminosa, espessuras de 2 mm de resina composta podem ser adequadamente polimerizadas utilizando-se fonte de luz halógena (600 mW/cm²) e LED (a partir de 300 mW/cm²) respectivamente. Contudo, estudos clínicos adicionais ainda são necessários para complementar este estudo / At this study it was evaluated the microhardness of the Z250 (3M ESPE) resin composite, when light cured for different periods of time (s), with different power densities (mW/cm²), related to the irradiated luminous energy density (8 J/cm², 12 J/cm² and 16 J/cm²), in order to establish a minimal energy density capable of adequately polymerize the composites. One halogen light curing unit Degulux- Degussa, with 600 mW/cm² of power density and two light-emitting diodes curing units Ultraled XP (Dabi-Atlante) with 150 mW/cm² and LED Ultrablue-IS (DMC) with 300 mW/cm² and 600 mW/cm² were used. Two bipartite PTFE matrices, with 1 and 2 mm of depth and a central orifice of 5 mm diameter, were used to make 60 specimens, 5 per group. The halves of the matrix were positioned inside a brass ring with both depths to prepare the specimens. The resin composite was inserted and light-activated according to the different periods and energy densities of each lightcuring unit. To evaluate Knoop microhardness, specimens were taken to a microdurometer Shimadzu HMV-2 with a static load of 300 g for 5 seconds, evaluating both exposed to light (surface) and opposite to light (base) exposition surfaces, totalizing 120 measurements. Results were submitted to ANOVA and Tukeys test with 5% significance level. Based on the obtained results, it was concluded that, starting from 16 J/cm² and 12 J/cm² of energy luminous density, 2 mm depth resin composite can be adequately polymerized utilizing halogen (600 mW/cm²) and LED ( starting from 300 mW/cm²) curing-units respectively. However, additional clinical studies are necessary to complement this investigation.
4

Inversor fotovoltaico não isolado NPC intercalado / Transformerless photovoltaic interleaved NPC inverter

Finamor, Gustavo Andres 04 March 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Throughout the twentieth century, the supply of electricity, mainly obtained from fossil fuels like oil and coal, it has supported the growth and transformation of the world economy. In the early years of this century, the scenario has changed to a new reality, the need for sustainable development. In other words, the challenge is to gradually replace the traditional sources of electricity from renewable energy sources, in which the solar photovoltaic energy has highlighted. Photovoltaic inverters may be constituted in different ways, presenting in recent decades a high research progress. The main study efforts focus on getting high efficiency, high power density and high reliability, to increase the overall performance of the photovoltaic installation. In this direction, this Master Thesis aims to propose, analyze, design and implement a single-phase grid-tied photovoltaic inverter, which provides high efficiency and high power density. This circuit is called Transformerless Photovoltaic Interleaved Multilevel NPC Inverter , that use uncoupled inductors, Gallium Nitride power transistors and employs interleaving strategy beside the LCL filter, synthesizing 9 levels. Are introduced studies on the operation, modulation and design methodology of power stages, considering the static performance. Results are presented for the 1 kW, in order to support the validity of the proposed topology in conjunction with the standard aspects, especially in relation to THD (Total Harmonic Distortion) of grid current, leakage current, efficiency and power density. / Durante todo o século XX, a oferta de energia elétrica, obtida principalmente a partir dos combustíveis fósseis como petróleo e o carvão mineral, deu suporte ao crescimento e as transformações da economia mundial. Já nos primeiros anos do século atual, o cenário mudou para uma nova realidade, a necessidade do desenvolvimento sustentável. Em outras palavras, o desafio é substituir gradativamente as fontes tradicionais de energia elétrica por fontes de energia renovável, onde a energia solar fotovoltaica tem destaque. Os conversores eletrônicos para sistemas fotovoltaicos, também chamados de inversores, podem ser constituídos de diversas maneiras, apresentando nas últimas décadas um acentuado progresso de pesquisa. Os principais esforços de estudo tem se concentrado em obter alto rendimento, alta densidade de potência e alta confiabilidade, de modo a aumentar o desempenho global da instalação fotovoltaica. Neste horizonte, esta dissertação tem por objetivo propor, analisar, projetar e implementar um inversor fotovoltaico monofásico, para aplicação conectada à rede, de alto rendimento e alta densidade de potência. Esta estrutura é denominada de Inversor Fotovoltaico NPC Multinível Intercalado sem Transformador , que utiliza indutores não acoplados, interruptores de Nitreto de Gálio e emprega a técnica interleaving junto ao filtro LCL, sintetizando 9 níveis. No decorrer do trabalho são introduzidos estudos relativos à operação, modulação, metodologia de projeto e estágios de potência, estabelecendo critérios, enquanto considera a performance estática. São apresentados resultados, observando a potência de 1 kW, com a finalidade de corroborar a validade da topologia proposta juntamente as normativas e aspectos que norteiam a aplicação, especialmente com respeito à THD (Total Harmonic Distortion) da corrente da rede, corrente de fuga, rendimento e densidade de potência.

Page generated in 0.0592 seconds