• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 114
  • 9
  • 9
  • 9
  • 9
  • 8
  • 8
  • 4
  • 4
  • 1
  • Tagged with
  • 114
  • 114
  • 85
  • 45
  • 34
  • 34
  • 32
  • 25
  • 24
  • 23
  • 22
  • 18
  • 16
  • 15
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação do tipo de procedimento odontológico, cirurgia x dentística restauradora, na variabilidade do tempo de duração de dois anestésicos : bupivacaína x prilocaína /

Santos, Lúcio Murilo dos. January 1997 (has links)
Orientador: Sigmar de Mello Rode / Banca: Fernando Ricardo Xavier da Silveira / Banca: Antenor Araujo / Resumo: Os anestésicos locais devido ao seu grande uso na odontologia, têm sido causa de inúmeros estudos na literatura odontológica, contudo a grande maioria destes avalia tão somente o tempo de duração destas drogas, ou tece comentários sobre seus efeitos tóxicos e interações sistêmicas. Com este estudo procura-se observar a existência de alteração na variação do tempo de duração de dois anestésicos, quando usados com a mesma técnica anestésica, porém em procedimentos odontológicos distintos. A metodologia consistiu na formação de dois grupos com 14 pacientes cada, sendo que o grupo um era formado por pacientes que necessitavam de bloqueio ptérigo-mandibular para exodontia dos terceiros molares inferiores, e o grupo dois constituía-se de 14 pacientes que foram submetidos à mesma técnica anestésica com intuito de tratamento em dentística restauradora. Os resultados foram analisados segundo o diagrama Blox-Plot, teste "t" de Student e Mann-Whitney. A análise dos resultados revelou que: a variabilidade no tempo de duração da Bupivacaína (Neocaína) e da Prilocaína (Citocaína) é grande, porém todos os valores se incluem nas suas respectivas amostras; o tempo de duração do dois anestésicos não se encaixam na curva de distribuição normal; o tempo de duração anestésica da Bupivacaína a 0,5% com adrenalina a I:200.000 é, através do estudo das medianas, 2,2 vezes maior que da Prilocaína a 3% com Felipressina a 0,03 UI/ml; e que o tipo de procedimento odontológico, cirúrgico ou restaurador, não influi na variabilidade do tempo de duração dos dois anestésicos utilizados neste estudo / Abstract: The local anesthetics due to because of the large use in dentistry have been motive of a great number of researchs, however the focus of these studies is the duration time, toxic effects and sistemic interactions. With this research we have the pourpose to observe if have alteration in the time of duration between two anesthetics when used with the same anesthetics techinic, but with distinct dental procedure. Two groups with 14 subjects each were formed: one with a necessity of lower wisdom teeth surgery, and the other that need restourative dentistry. The results obtained were analysed by the Blox-Plot diagram, "t" test of Student and Mann-Whitney test. The data analysis show that have a significative variability of the duration time of bupivacaine and prilocaine, but all the datas are include in the same group; the duration time of both anesthetics don't follow the normal distribution courve; the anesthetic duration of bupivacaine 0,5% with epinephrine I: 200.000 is, in the median study, 2,2 major time that the prilocaine 3% with felipressin 0,03 UI/ml; and that the odontologic procedure mode, make no difference in the variability of duration time of two anesthetics used in this study / Mestre
12

Avaliação da adaptação marginal de dois sistemas cerâmicos, IPS Empress e Cerec inLAB, em restaurações MOD

Delbons, Flávia Barros January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-22T23:39:21Z (GMT). No. of bitstreams: 1 239121.pdf: 2514154 bytes, checksum: ff184df500667299038e586fa05a2f70 (MD5) / Este estudo teve como objetivo avaliar, in vitro, a adaptação marginal de dois sistemas cerâmicos, IPS Empress e Cerec inLab, em restaurações indiretas do tipo MOD. Para isso, foram realizados 10 preparos convencionais para inlays cerâmicos MOD, em molares hígidos. Para cada dente preparado, foram confeccionadas duas peças cerâmicas, uma de cada sistema. A análise da adaptação marginal de cada dente com a sua respectiva peça cerâmica antes e após o ajuste, quando esse se fez necessário e de cada peça no seu respectivo modelo de gesso, foi realizada em um microscópio óptico com um aumento de 70 vezes. De acordo com os resultados obtidos, pôde-se concluir que, em preparos MOD para incrustações cerâmicas, o sistema IPS Empress, além de oferecer maior adaptação marginal, requer menos ajustes da peça, quando comparado com o sistema Cerec
13

Restauração de dentes tratados endodonticamente

Melo, Tiago Spezia de January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-23T04:23:16Z (GMT). No. of bitstreams: 1 241995.pdf: 5149493 bytes, checksum: 241e01a69ea2e9e686a74e63bf6fbc9b (MD5) / O objetivo deste estudo in vitro foi comparar o desempenho mecânico de três abordagens indicadas para restauração de dentes posteriores desvitalizados, por meio da avaliação da resistência e do padrão de fratura. Para isso, quarenta terceiros-molares hígidos foram selecionados e divididos em quatro grupos (n=10): endocrown cerâmica (G1); núcleo de preenchimento / coroa cerâmica (G2); pino fibro-resinoso / núcleo de preenchimento / coroa cerâmica (G3). Para facilitar a comparação dos resultados, também foi incluído um grupo controle, formado por dentes hígidos (G4). Nos grupos G1, G2 e G3, os dentes foram tratados endodonticamente e preparados para restaurações cerâmicas, que foram usinadas a partir de blocos CEREC ProCAD e cimentadas adesivamente a cada um dos preparos. Após a termociclagem, os corpos-de-prova foram montados em uma máquina universal de ensaios, na qual foram submetidos a uma carga de compressão até a ocorrência de fratura. A avaliação estatística identificou diferenças significantes entre os grupos, tanto em relação à resistência quanto ao padrão de fratura. A maior média de resistência foi detectada no G4 (2951,49 N), porém esse valor não foi estatisticamente diferente da média do G2 (2057,02 N). Os menores valores foram observados no G1 (1670,74 N), ao passo que o G3 (1989,59 N) ocupou posição intermediária ao G1 e G2. Em relação ao padrão de fratura, foi observado um aumento progressivo de complexidade do G4 para o G2 e G3, e destes para o G1 (G4 < G2 e G3 < G1). Esses resultados indicam que o desempenho mecânico de restaurações mistas, que associam cerâmica e compósito, é superior ao desempenho de restaurações exclusivamente cerâmicas. The aim of this in vitro study was to compare the fracture strength and fracture pattern of three restorative approaches recommended for restoring non-vital posterior teeth. Forty extracted third molars were selected and randomly assigned to four groups (n=10), according to the following outline: ceramic endocrowns (G1); composite core / ceramic crown (G2); fiber post / composite core / ceramic crown (G3); non-restored teeth (G4). Groups G1, G2 and G3 were endodontically treated and prepared for ceramic restorations, which were milled from CEREC ProCAD blocks and bonded to each prepared tooth. After thermocycling, the specimens were loaded to fracture in a universal testing machine. Statistical analysis showed significant differences between the groups, for both the fracture strength and fracture pattern. The highest resistance to fracture was detected on G4 (2951.49 N), even though this value was statistically similar to G2 (2057.02 N). The lowest average strength was detected in G1 (1670.74 N), with G3 (1989.59 N) showing values intermediate to G1 and G2. Regarding the fracture pattern, a progression of the complexity was observed from G4 to G2 and G3, and from these to G1 (G4 < G2 and G3 < G1). These results indicate that the mechanical performance of restorations that combine composite and ceramic is superior to the mechanical performance of purely ceramic restorations.
14

Avaliação da resistência ao desgaste abrasivo de resinas compostas universais

Ferreira, Kazuza Bueno January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2012-10-23T04:36:43Z (GMT). No. of bitstreams: 1 240718.pdf: 16827340 bytes, checksum: e14907b15a3d3f3305fd3177beba3780 (MD5) / O objetivo desse estudo, in vitro, foi avaliar a resistência ao desgaste abrasivo das resinas compostas universais Charisma/CH (Heraeus Kulzer), Esthet-X/EX (Dentsply Caulk), Fill Magic/FM (Vigodent), Filtek Supreme/SU (3M ESPE), Filtek Z100/ Z1 (3M ESPE), Filtek Z250/Z2 (3M ESPE), Herculite XRV/HE (Kerr Dental), Opallis/OP (FGM), Te-econom/TN (Ivoclar Vivadent) e Tetric Ceram/TC (Ivoclar Vivadent). Foram confeccionados 8 corpos-de-prova, na cor A2, com formatos cilíndricos (8,0 mm de diâmetro X 2,0 mm de espessura) de cada material. A resistência ao desgaste abrasivo foi avaliada através de análises das alterações na massa e na rugosidade superficial das amostras submetidas à escovação simulada. As mensurações iniciais (pré-escovação simulada) e finais (pós-escovação simulada) de massa foram obtidas através de balança eletrônica com precisão de 0,0001g. As aferições iniciais e finais da rugosidade superficial foram feitas com uma sonda mecânica de 5µm acoplada ao rugosímetro Perthometer S8P (Mahr), com velocidade constante de 0,15mm/s e força de 0,8mN, utilizando o parâmetro de medição Ra expresso em µm, com cut-off de 0,25mm e comprimento de avaliação de 1,25mm. O teste abrasivo foi realizado em uma máquina de escovação simulada, utilizando escovas dentais de cerdas macias e pontas arredondadas, sob 200g de carga, com velocidade de 374 ciclos/min e solução de dentifrício e água deionizada na proporção de 1:2. As amostras foram submetidas a 50.000 ciclos de escovação. As escovas foram substituídas a cada 25.000 ciclos e a solução foi constantemente reposta durante o teste. Para a avaliação das alterações decorrentes do teste abrasivo foram calculadas as diferenças entre as médias finais e iniciais de massa e de rugosidade superficial e os valores obtidos foram convertidos em porcentagem. Os dados foram analisados estatisticamente através dos testes t pareado, ANOVA, Scheffé e correlação de Pearson (p<0,05). Os resultados demonstraram que todos os materiais apresentaram redução estatisticamente significante da massa e aumento estatisticamente significante da rugosidade superficial após a escovação simulada (p < 0,0001). Considerando as alterações na massa, a ordem crescente de resistência à abrasão dos materiais avaliados foi (OP=Z2) > Z1 > TC > (HE=CH) > FM > TN > SU > EX. Com relação às alterações na rugosidade superficial, a ordem crescente de resistência à abrasão dos materiais avaliados foi EX > (HE = SU = TC = CH = FM) > (TC = CH = FM = OP) > (OP = Z2 = TN = Z1). Os métodos de avaliação de resistência ao desgaste não possuem correlação. Com base nos resultados concluiu-se que dentre as resinas compostas universais avaliadas existem diferenças na resistência à abrasão, entretanto, todas desgastam e ficam mais rugosas em conseqüência de forças abrasivas por escovação simulada. As alterações de massa e de rugosidade superficial das resinas compostas não estão correlacionadas.
15

Compósito reforçado com fibra de vidro pré-tracionada

Schlichting, Luís Henrique January 2007 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-23T11:32:09Z (GMT). No. of bitstreams: 1 238783.pdf: 5278756 bytes, checksum: f23141ac3300d385b1b74fcd95605538 (MD5) / O objetivo deste estudo foi avaliar a influência da protensão nas propriedades flexurais de duas resinas compostas, uma de uso direto (Quixfil) e outra de uso indireto (Adoro), reforçadas com fibra de vidro pré-tracionada. Foram realizados testes preliminares de resistência à compressão, para as resinas, e de aderência interfacial entre a fibra e as resinas (pull-out). Nos grupos experimentais, os espécimes foram reforçados com dois feixes de fibra, simetricamente posicionados próximo da base e do topo, pré-tracionados sob uma carga equivalente a 73,5% da resistência à tração (0,496KN). Nos grupos controle, os feixes foram posicionados exatamente como nos grupos experimentais, entretanto sem qualquer tração prévia. Adicionalmente, foram incluídos mais dois grupos, com as mesmas dimensões (2x2x25 mm), porém sem reforço de fibra. Após armazenagem de 24 h, os espécimes foram submetidos ao teste flexural de três pontos para determinar o módulo flexural, a deflexão correspondente à falha inicial e à resistência flexural. Os dados foram analisados pelo testes de análise de variância e Tukey HSD. Os resultados demonstraram que a protensão aumentou discretamente o módulo flexural da resina de uso indireto Adoro, enquanto para a resina de uso direto Quixfil não foram observadas alterações significativas. Os espécimes protendidos precisaram alcançar deflexões maiores do que os espécimes com reforço convencional para o início do processo de falha (um aumento de 33% para Quixfil e 58% para Adoro). A protensão também determinou incrementos significantes na resistência flexural dos espécimes (28,3% para Adoro e 33,5% para Quixfil). The purpose of this study was to evaluate the influence of prestressing on the flexural properties of two composite resins, a direct composite resin (Quixfil) and an indirect composite resin (Adoro), reinforced with pre-tensioned fiber glass. It was accomplished a preliminary compressive strength test of composite resins and the interfacial adherence test among fiber glass and composite resins (pull-out). In the experimental groups, specimens were reinforced with two fiber bundles symmetrically positioned along the bottom and top, pre-tensioned under a load equivalent to 73.5% of tensile strength (0.496 kN). In the control groups, the bundles were positioned exactly as in the experimental groups, except with no previous stress. Additionally, two groups were included in this study with the same dimensions (2x2x25 mm), except with no fiber reinforcement. After 24h storage, specimens were subjected to a three point flexural bending test to establish the flexural module, the deflection regarding the initial failure and the flexural strength. Data were analyzed using ANOVA and Tukey HSD tests. The results showed that prestressing increased slightly the flexural module of indirect composite resin Adoro, while direct composite resin Quixfil didn't demonstrate significant changes. The prestressed specimens needed to reach greater deflection than specimens with conventional reinforcement for the beginning of failure process (an increase of 33% for Quixfil and 58% for Adoro). The prestressing also determined significant increments on the flexural strength of specimens (28.3% for Adoro and 33% for Quixfil).
16

Influência da reconstrução do ângulo áxio-pulpar na resistência à fratura de molares restaurados com inlays cerâmica

Morelli, Elaine Auxiliadora Vilela Maia January 2005 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-graduação em Odontologia / Made available in DSpace on 2013-07-16T01:49:11Z (GMT). No. of bitstreams: 0 / O presente estudo avaliou a influência da configuração cavitária (reconstruindo ou não o ângulo áxio-pulpar) na resistência à fratura de molares restaurados com inlays cerâmicas. Os resultados demonstraram que não houve diferença estatística na resistência à fratura entre os dentes com preparo MOD convencional (grupo 1 - 1,42kN) e dentes íntegros (grupo 6 - 1,68kN). Os grupos 2 (1,20kN), 3 (1,08kN), 4 (1,01kN) e 5 (1,21kN) apresentaram menor resistência à fratura. Contudo, não apresentaram diferenças estatisticamente significantes entre si. Os resultados sugeriram que o fator mais importante na resistência à fratura foi o volume de estrutura dental remanescente. Ao final do ensaio mecânico, as fraturas mais freqüentes para os grupos 1, 2, 3 e 4 eram os tipos III e IV, ao passo que, no grupo 5, as fraturas severas (tipo V) foram mais predominantes
17

Influência da contaminação pela manipulação durante o procedimento restaurador sobre as propriedades mecânicas de duas resinas compostas fotopolimerizáveis

Heck, Mary A. Pereira January 2006 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde. Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2013-07-16T03:03:32Z (GMT). No. of bitstreams: 1 233708.pdf: 8835447 bytes, checksum: e1300eefa6cf5aba2543b86c418c5354 (MD5) / Avaliou-se, in vitro, o efeito da contaminação pela manipulação digital sobre a microdureza e resistência flexural das resinas Tetric Ceram e Filtek Z250, e identificou-se os agentes contaminantes por meio da microanálise por energia dispersiva. Os resultados mostraram que a manipulação com luva contaminada e luva contaminada limpa com álcool diminuiu a microdureza superficial e a resistência à flexão, independentemente das resinas. A manipulação com luva nova e espátula não levou a alteração. A observação dos corpos de prova com a microssonda do MEV identificou os seguintes agentes contaminantes: magnésio, níquel, cálcio, cloro, potássio e aumento da quantidade de carbono e oxigênio em alguns corpos de prova.
18

Aspectos tradutórios da interação entre modalidades semióticas

Souza, Raquel Ghizzo de January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Comunicação e Expressão. Programa de Pós-Graduação em Estudos da Tradução / Made available in DSpace on 2012-10-22T09:58:50Z (GMT). No. of bitstreams: 1 225335.pdf: 623761 bytes, checksum: 81dfa5390cd2dca360312238a5f67431 (MD5) / Nesta pesquisa, abordam-se textos de natureza técnico-científica, da área da Odontologia, circunscritos na especificidade Dentística. O objetivo seria examinar técnicas de tradução adotadas pelo tradutor no processo de transposição de códigos, a saber: do português para o inglês, e examinar de que forma ocorre a interação entre duas modalidades semióticas diferentes: o texto escrito e a parcela imagística. Esta parcela imagística, freqüentemente, constitui elemento de complementação nocional destes textos, em razão da complexidade da anatomia humana e dos procedimentos cirúrgicos e de manipulação implicados. Para levar a cabo esta proposta de trabalho selecionamos teorias como a Teoria Sistêmico Funcional (HALLIDAY; MATTHIESSEN, 1997, 2004) e a Teoria Semiótico-Social de Representação (KRESS e LEEUWEN, 1996). Além disso, na lingüística contamos com os procedimentos de tradução, como os descritos por Vinay e Darbelnet - que, também, servem de suporte para este estudo. O corpus examinado é constituído por enunciados contidos no livro intitulado: "Dentística/ Procedimentos Preventivos e Restauradores", de autoria do Prof. Dr. Luiz Narciso Baratieri e Cols (1989). Através deste estudo, foi possível constatar que a atividade tradutória de uma língua de especialidade exige, em muitos casos, conhecimentos de natureza técnica, além do domínio de elementos de ordem lingüística tanto do código-fonte quanto do código alvo.
19

Avaliação de LEDs de alta intensidade quanto à eficiência de polimerização de resina composta e variação de temperatura na dentina bovina

Mollica, Fernanda Brandão [UNESP] 29 June 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2007-06-29Bitstream added on 2014-06-13T20:31:06Z : No. of bitstreams: 1 mollica_fb_me_sjc.pdf: 859430 bytes, checksum: 9995882b109a407d775d587ef3cb2f1c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo avaliar a eficiência de polimerização de uma resina composta (RC) e a variação de temperatura na dentina bovina, empregando aparelhos de Diodo Emissor de Luz (LED) de alta intensidade em comparação a um aparelho de Quartzo-Halogênio-Tungstênio (QTH). Os aparelhos utilizados foram: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) e LED Radii (SDI, 1400 mW/cm2) e a RC, a Esthet X (Dentsply). Para o teste de microdureza Vickers, foram confeccionados 84 corpos-de-prova (2 mm x 5 mm) em matriz de teflon bipartida, variando-se o tempo de exposição em 10, 20 e 40 s, sendo que o aparelho XL 3000 foi utilizado para o grupo controle apenas pelo tempo de 40 s. Após 24 h, realizou-se o teste de microdureza no topo e na base dos corpos-de-prova com carga de 50 g e duração de 15 s. Para a medida da variação de temperatura ocasionada pelos aparelhos, foram utilizadas 45 fatias de dentina bovina de 0,7 mm de espessura e termopar tipo T conectado a um sistema de aquisição de dados ADS 2000 IP (Lynx Tecnologia). As fatias foram divididas em três grupos, sendo a variação de temperatura medida em três etapas: 1) durante a fotopolimerização do adesivo (10 s); 2) durante a fotopolimerização da RC (40 s) e 3) após 24 h (40 s). Os valores de microdureza do topo e da base e os dados de temperatura foram submetidos ao teste ANOVA de medidas repetidas e aos testes de Tukey e Dunnet (p=5%). Os resultados revelaram diferença estatística significante de microdureza no topo e na base quando se utilizaram ambos os LEDs por 10 s em relação ao uso do XL 3000 por 40 s, não havendo diferenças estatísticas entre os grupos com os tempos de 20 s e 40 s. A utilização do LED Radii pelos tempos de 10 e 20 s não foi suficiente... / The aim of this study was to evaluate the efficiency of polymerization of a resin composite and the temperature variation in bovine dentine, using two curing units of Light Emitting Diode (LED) of high intensity in comparison to a Quartz-Halogen-Tungsten device (QTH). The light curing units used were: Curing Light XL 3000 (3M, 600 mW/cm2), LED SmartLite PS (Dentsply, 950 mW/cm2) and LED Radii (SDI, 1400 mW/cm2) and the resin composite, Esthet X (Dentsply). For the test of Vickers microhardness, 84 specimens (2 mm X 5 mm) were prepared in bipartite matrix of teflon, varying the time of exposition in 10, 20 and 40 s. The curing unit XL 3000 was used for the control group for 40 s. After 24 h, the microhardness test was made on the top and base of the specimens with 50 g of load and 15 s of duration. For the temperature variation measurement caused by the different curing units, 45 slices of bovine dentine of 0.7 mm thickness and a thermocouple type T hardwired to a system of data acquisition ADS 2000 IP (Lynx Technology) were used. The slices were divided in three groups and the temperature variation was measured in three stages: 1) during the adhesive photopolymerization (10 s); 2) during resin composite photopolymerization (40 s) and 3) after 24 h (40 s). The values of microhardness of the top and the base and the data of temperature variation were submitted to ANOVA of repeated measures test and to the tests of Tukey and Dunnet (p=5%). The results showed statistical significant difference of microhardness for the top and base values when both LEDs were used for 10 s in relation to the use of XL 3000 for 40 s, but no statistical differences were found between the groups when the exposition time was 20 s and 40 s. The use of LED Radii for 10 s and 20 s was not enough to equal statistically ... (Complete abstract, click electronic access below)
20

Estabilidade mecanica de proteses fixas sobre retentores do tipo coroa total

Silva, Wilkens Aurelio Buarque e, 1967- 14 November 1996 (has links)
Orientador: Frederico Andrade e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-21T21:22:32Z (GMT). No. of bitstreams: 1 Silva_WilkensAurelioBuarquee_D.pdf: 4715185 bytes, checksum: 2f0fd4a9ae36d7a9ec0b70f8bd967723 (MD5) Previous issue date: 1996 / Resumo: O objetivo deste trabalho foi avaliar a estabilidade mecânica de pontes fixas, através da variação de forças compressivas verticais, de sentido ocluso cervical, aplicadas nas vertentes oclusais internas dos retentores e pônticos; sendo os corpos de prova adaptados em preparos do tipo coroa total, com e sem canaletas axiais proximais e variando-se a convergência das paredes axiais. Os preparos com 5mm de altura cervico-oclusal e ombro maior que 90°, foram confeccionados com as seguintes convergências: 16°, 24° e 32° de convergência total, com e sem canaletas axiais proximais (0,7mm de profundidade e 4mm de altura). Para cada hemi-arco foi confeccionado um corpo de prova com características morfofuncionais de uma ponte fixa, cujos retentores foram o 2° molar e o 2° pré-molar, e pônticos o 1° molar e o 1° pré-molar (pôntico em "cantilever"). Para avaliação da estabilidade mecânica, os corpos de prova adaptados em seus respectivos preparos, foram submetidos à cargas verticais de intensidade 3kg, 5kg, 10kg, 15kg e 20kg em uma máquina de ensaio universal, com velocidade' constante em 1mm/min. O registro dos resultados consistiu em observar a ocorrência ou não de deslocamento dos corpos de prova. Os resultados obtidos revelaram que: a) Os retentores adaptados sobre preparos com 12° e 16° em cada parede axial, sem canaletas axiais proximais, obtiveram médias de deslocamento significativamente superiores aos adaptados em preparos com 8°; b) O aumento na intensidade das forças compressivas diminuiu a estabilidade dos corpos de prova. c) As forças induzidas no "cantilever", proporcionaram as maiores médias de deslocamento; d) As canaletas axiais proximais reduziram significativamente as médias de deslocamentos dos corpos de prova nos grupos com 12° e 16° de convergência em cada parede axial; e) As canaletas axiais proximais não foram devidamente efetivas em antagonizar as forças induzidas no "cantilever" / Abstract: The purpousal of this research, was to evaluate the mechanical stability of full crown preparations, over vertical compressive forces, applied in the occlusal vertents of the pontics and retainers of fixed partial prothesis, with or without the presence of proximal axial grooves, changing the convergence of the axial walls. The preparations with sholder larger than 90°, were made with the following convergences: 8°, 12° and 16° in each of the axial walls, with or without proximal axial grooves, of 0,7mm deep and 4mm length. The cervico-occlusal height of the preparations was 0,5mm. For each hemi-archs, was made a pattern like a four elements fixed partial denture: 2nd. molar (retainer), 1st. molar (pontic), 2nd. pre-molar (retainer) and the 1st.pre-molar (cantilever). To evaluate the resistance form of the preparations, the pattern adjusted in yours respective preparations, were submited to vertical forces of intensity 3kg, 5kg, lOkg, 15kg and 20kg in a universal testing machine, with speed in 1mm/min. The record of the results was to observe the occours of dislodgement of the patterns. The obtained results shows: a) the retainers adjusted in 12° and 16° preparations, had statisticaly higher average of dislocation to the adjusted in 8°; b) The increase of vertical force, decreased the the stability; c) The vertical force induced in the cantilever, provides the higher averages of dislocation; d) The proximal axial grooves decreased the average of dislocation, in 12° and 16° preparations groups; e) The proximal axial grooves, were not completely effective in provides stability, on cantilever pontics / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Page generated in 0.1081 seconds