• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 49
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 168
  • 98
  • 76
  • 44
  • 35
  • 35
  • 33
  • 32
  • 30
  • 29
  • 29
  • 28
  • 27
  • 26
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Efeito da imersão em soluções desinfetantes na capacidade de formação de biofilme de C.albicans e características topográficas de uma resina acrílica para base de prótese e um reembasador /

Amaya Arbeláez, Maria Isabel January 2016 (has links)
Orientador: Janaina Habib Jorge / Resumo: O presente estudo teve como objetivo avaliar a capacidade de formação de biofilme de Candida albicans sobre resinas acrílicas para base (Vipi Wave) e reembasamento (Tokuyama Rebase Fast II) de próteses, após imersão diária por períodos de até 6 meses em soluções desinfetantes. Foram confeccionados 360 corpos de prova circulares de cada resina acrílica usando uma matriz metálica (14 x 1,2 mm). As amostras foram imersas overnight durante 0, 1, 3, e 6 meses em 5 soluções desinfetantes: hipoclorito de sódio 0,5%, perborato de sódio 3,8%, digluconato de clorexidina 2%, vinagre de maçã puro (Minhoto®) e água destilada (grupo controle). Após os diferentes períodos de imersão, um biofilme maduro de 48h de C. albicans (cepa ATCC 90028) foi formado sobre os corpos de prova. A capacidade de formação deste biofilme foi analisada utilizando o método de contagem de colônias (UFC/mL) e o ensaio de viabilidade celular Alamar Blue®. Para todos os grupos experimentais, imagens foram obtidas a partir de microscopia eletrônica de varredura (MEV) para avaliação das características topográficas das resinas após a imersão nos diferentes tempos. Todas os experimentos foram realizados em três ocasiões independentes. Análise de variância de três fatores (ANOVA) foi utilizada para avaliar o metabolismo celular (ensaio Alamar Blue®) e os valores de UFC/mL obtidos a partir da formação do biofilme de C. albicans. Foi adotado o nível de significância de 5%. Os resultados de Alamar Blue® mostraram um efeito... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
82

Avaliação eletromiográfica e análise da qualidade de vida de edentados totais antes e após o reembasamento das próteses inferiores / Electromyographic evaluation and oral health related quality of life of edentulous before and after mandibular denture relining

Pisani, Marina Xavier 30 May 2012 (has links)
O presente estudo teve como objetivo geral analisar o impacto do reembasamento de próteses totais com reembasadores rígido e macio na atividade eletromiográfica e na qualidade de vida relacionada à saúde oral (OHRQoL) de pacientes edentados totais. Quarenta e quatro usuários de próteses totais superiores e inferiores foram distribuídos em dois grupos. No grupo 1 (n=22), as próteses inferiores foram reembasadas com reembasador macio à base de silicone (Mucopren Soft) e no grupo 2, com reembasador rígido à base de resina acrílica (Kooliner) pela técnica direta. A avaliação eletromiográfica dos músculos masseter e temporal e análise da OHRQoL foram realizadas antes do reembasamento (baseline-T0) e após 90 dias (T90) da intervenção. Para avaliação da OHRQoL, foi aplicado o questionário OHIP-EDENT, composto por quatro domínios, e três possíveis respostas (escores) às questões: nunca (0), às vezes (1) e quase sempre (2). Após normalização do sinal eletromiográfico, os pacientes foram instruídos a realizarem a máxima contração voluntária em MIH (teste estático), e as variáveis consideradas foram: POC (%), tors (%) e total de atividade eletromiográfica ou impacto (μV / μ V.s %). Em seguida, mastigaram amendoins, barra de cereal e chocolate (teste dinâmico), com as seguintes variáveis: coordenação neuromuscular (%), frequência (Hz) e impacto (μV / μV.s %). Os resultados foram analisados por meio do modelo linear generalizado (p≤0,05). A comparação dos escores da OHRQoL indicou diferença significante entre T0 e T90, independente do grupo, representando uma melhoria nas questões relacionadas à mastigação (domínio 1; p=0,007), dor oral e desconforto (domínio 4; p= 0,047) e no OHIP em geral (p=0,025). Não houve diferença entre os grupos para nenhum dos domínios e para o OHIP em geral. Os resultados do POC dos músculos masseter e temporal não indicaram diferença significante entre os tempos (POCmas p=0,147; POCtem p=0,469) e entre os grupos (POCmas p=0,549; POCtem p=0,104). Para o tors, não foi encontrada diferença significante entre os grupos (p=0,971), e, houve redução do tors em T90 (p=0). Não houve diferença significante entre os grupos (p=0,067), para o impacto, que aumentou em T90 (p=0). A coordenação neuromuscular durante a mastigação de chocolate (p=0), barra de cereal (p=0) e amendoim (p=0) aumentou em T90 e não houve diferença significante entre os grupos (chocolate p=0,087; barra p=0,185; amendoim p=0,472). Não foi encontrada diferença significante entre os grupos (p=0,530) e tempos (p=0,685) para a frequência da mastigação de chocolate. Para o amendoim e barra de cereal, a frequência aumentou em T90 (amendoim p=0,03; barra p=0,007) e não houve diferença entre os grupos (amendoim p=0,566; barra p=0,173). O impacto, durante mastigação de chocolate, aumentou em T90 (p=0), onde o grupo rígido apresentou maior valor (p=0,018). Durante a mastigação de amendoim e barra de cereal, o impacto aumentou em T90 (amendoim p=0; barra p=0) e não houve diferença significante entre os grupos (amendoim p=0,428; barra p=0,590). Conclui-se que o reembasamento, promoveu aumento na atividade eletromiográfica dos músculos avaliados, bem como melhorias na função mastigatória e na OHRQoL. Para a maioria das variáveis não houve diferença significante entre os reembasadores macio e rígido. / The present study aimed to analyze the impact of denture relining with hard and soft denture liners in the electromyographic activity and oral health related quality of life (OHRQoL) of edentulous patients. Forty and four complete denture wearers were distributed in two groups. In group 1 (n=22), the mandibular dentures were relined with a soft silicone based liner (Mucopren Soft) and in group 2, with a hard acrylic based denture liner (Kooliner) by chairside procedures. The electromyography of masseter and temporal muscles and the OHRQoL analysis were assessed before relining (baseline-T0) and after 90 days (T90) of the intervention. The questionnaire OHIP-EDENT, that was used to evaluate the OHRQoL, is composed of four domains, and three possible answers (scores) to the questions: never (0), sometimes (1) and almost always (2). After the normalization of the electromyographic signal, patients had been instructed to perform the maximum voluntary contraction in MIH (static test), and the following variables were considered: POC (%), tors (%) and total of electromyographic activity or impact (μV / μV.s %). After that, they performed masticatory movements by chewing peanuts, cereal bar and chocolate (dynamic test), with the following variables: neuromuscular coordination (%), frequency (Hz) and impact (μV / μV.s %). The results were analyzed by means of the generalized linear model (p≤0,05). The scores comparison of the OHRQoL indicated significant difference among T0 and T90, regardless the group, which represented an improvement in questions related to mastication (domain 1; p=0,007), oral pain and discomfort (domain 4; p= 0,047) and in overall OHIP (p=0,025). There was no significant difference between the groups for none of the domains and for the overall OHIP. Regarding POC of masseter and temporal, no significant differences between times (POCmas p=0,147; POCtem p=0,469) and groups (POCmas p=0,549; POCtem p=0,104) were found. For tors, significant difference between the groups was not found (p=0,971), and, it decreased in T90 (p=0). There was no significant difference between the groups (p=0,067), for the impact, which increased in T90 (p=0). The neuromuscular coordination during chocolate (p=0), cereal bar (p=0) and peanut (p=0) mastication increased in T90 and there was no significant difference between the groups (chocolate p=0,087; cereal p=0,185; peanut p=0,472). Significant difference between the groups (p=0,530) and times (p=0,685) for the frequency during chocolate mastication was not found. For peanut and cereal bar, the frequency increased in T90 (peanut p=0,03; cereal p=0,007) and there was no difference between the groups (peanut p=0,566; cereal p=0,173). The impact, during chocolate mastication, increased in T90 (p=0), and the hard group presented higher values than the soft (p=0,018). For peanut and bar of cereal mastication, the impact increased in T90 (peanut p=0; bar p=0) and there was no significant difference between the groups (peanut p=0,428; bar p=0,590). It can be concluded that the relining increased the electromyographic activity of the evaluated muscles and improved the masticatory function and the OHRQoL. There was no significant differences among the hard and soft denture liners for most of the tested variables.
83

Soluções higienizadoras de prótese total: avaliação da remoção de biofilme e efeito sobre propriedades da resina acrílica termopolimerizável / Denture cleansing solutions: evaluation of the biofilm removal and effect on properties of heat-polymerized acrylic resin

Peracini, Amanda 31 May 2012 (has links)
Este estudo avaliou o efeito de soluções higienizadoras de próteses totais quanto ao controle do biofilme (análise clínica) e à alteração de propriedades da resina acrílica (análise laboratorial). A análise clínica foi realizada em 32 desdentados totais que foram orientados a escovar suas próteses (escova Denture e sabonete líquido) três vezes ao dia e imergí-las (″overnight″) nas soluções: 1) Controle: Água Natural; 2) Pastilha Corega Tabs; 3) Hipoclorito de Sódio 0,5%. Cada solução foi utilizada por 21 dias (03 ciclos de 07 dias). Ao final de cada ciclo, a superfície interna da prótese superior foi evidenciada (vermelho neutro 1%) e fotografada (HX1- Sony). As áreas (total e corada com biofilme) foram medidas (Image Tool 3.00), sendo a porcentagem de biofilme calculada como a relação entre a área do biofilme multiplicado por 100 e área da superfície total da base interna da prótese. Para a análise laboratorial, foram confeccionados 140 corpos de prova de resina acrílica termopolimerizável (Lucitone 550) que foram imersos por 08 horas nas soluções: 1) Controle 1 (sem imersão); 2) Controle 2 (água destilada); 2) Pastilha Corega Tabs; 3) Hipoclorito de sódio 0,5%, simulando uma higienização diária de 03 anos (1095 dias). Antes e após as imersões, os corpos de prova foram avaliados quanto à alteração de cor (Espectrocolorímetro Color Guide 45/0), rugosidade superficial (rugosímetro Surftest SJ-201P) e resistência à flexão (Máquina Universal de Ensaios DL 2000). Os dados de cor foram também calculados de acordo com a National Bureau of Standards (NBS). As análises estatísticas compreenderam o método de equações de estimação generalizadas (GEE) e comparações múltiplas (Teste de Bonferroni - α = 1,67%) para análise clínica; e Análise de Variância (ANOVA) e teste HSD de Tukey (α=0,05) para análise laboratorial. Os resultados clínicos mostraram que a imersão em hipoclorito de sódio 0,5% diminuiu a área coberta por biofilme (8,29 ± 13,26 - B), quando comparado ao controle (18,24 ± 14,91 - A) e à pastilha (18,18 ± 16,62 - A). O hipoclorito (2,75 ± 0,49 - B) e a pastilha (3,01 ± 0,35 - B) provocaram alteração de cor significativamente maior que o controle (0,66 ± 0,29 A), sendo classificadas como perceptível, segundo a NBS. As soluções não alteraram a rugosidade da resina. Houve uma diminuição na resistência à flexão dos grupos pastilha (85,61 ± 10,46 - C) e hipoclorito (82,17 ± 8,47 - C) quando comparados com o controle (sem imersão) (105,4 ± 14,93 - A). O controle (água destilada) apresentou uma redução na resistência à flexão (67,06 ± 11,89 - B). Os achados deste estudo revelaram que a solução de hipoclorito de sódio 0,5% foi a mais efetiva na remoção do biofilme das próteses totais e que ambas as soluções (hipoclorito de sódio 0,5% e peróxido alcalino) não alteraram a rugosidade superficial, porém provocaram alterações de cor classificadas como perceptíveis segundo a NBS, bem como acarretaram uma diminuição da resistência à flexão da resina acrílica termicamente ativada. / This study evaluated the effect of denture cleansers on denture biofilm removal (clinical trial) and changes the properties of acrylic resin (laboratory analysis). A randomized clinical trial was performed in 32 edentulous patients who were instructed to brush their dentures (denture-specific brush and liquid soap) three times a day and to soak them overnight in the solutions: 1) Control: Water; 2) Efervescent Tablet (Corega Tabs); 3) 0.5% Sodium Hypochlorite. Each solution was used for 21 days (03 alternate cycles of 07 days). At the end of each cycle, the inner surfaces of maxillary dentures were disclosed (1% neutral red) and photographed (HX1 Sony). Total and stained biofilm areas were measured (Image Tool 3.00), and the percentage of biofilm calculated as the ratio between the area of the biofilm multiplied by 100 and total surface area of the internal base of the denture. For laboratory analysis, 140 specimens were prepared from heat-polymerized acrylic resin (Lucitone 550) and immersed for 08 hours in the solutions: 1) Control 1 (without immersion); 2) Control 2 (distilled water); 3) Efervescent Tablet Corega Tabs; 4) 0.5% Sodium Hypochlorite, simulating a daily hygiene of 03 years (1095 days). Before and after immersion, specimens were evaluated for color change (portable colorimeter Color Guide 450), surface roughness (Surface Roughness Tester SJ-201P) and flexural strength (universal testing machine DL 2000). Color data were also calculated according the National Bureau of Standards (NBS). Statistical analysis comprised the method of generalized estimating equations (GEE) and multiple comparisons (Bonferroni - α = 1.67%) for clinical analysis, and analysis of variance (ANOVA) and Tukey′s HSD test (α=0.05) for laboratory analysis. Clinical results showed that the immersion in sodium hypochlorite 0.5% reduced the area covered by biofilm (8.3 ± 13.3 - B) compared to the control (18.2 ± 14.9 - A) and tablet (18.2 ± 16.6 - A). Hypochlorite (2.8 ± 0.5 - B) and tablet (3.0 ± 0.4 - B) caused significantly higher color change than the control (0.7 ± 0.3 A); such changes were classified as noticeable, according to NBS. The solutions did not alter the roughness of the resin. There was a decrease in the flexural strength of the groups tablet (85.6 ± 10.5 - C) and hypochlorite (82.2 ± 8.5 - C) compared to control (without immersion) (105.4 ± 14.9 - A). The control (distilled water) showed a reduction in flexural strength (67.1 ± 11.9 - B). The findings revealed that the 0.5% sodium hypochlorite solution was the most effective for biofilm removal from complete dentures and that both solutions (0.5% sodium hypochlorite and alkaline peroxide) did not alter surface roughness, but caused color changes classified as noticeable according to the NBS, and resulted in a decrease of flexural strength of heat-polymerized acrylic resin.
84

Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /

Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
85

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável /

Gonçalves, Alessandro Ribeiro. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Carlos Eduardo Vergani / Banca: João Neudenir Arioli Filho / Banca: Arlindo Abreu de Castro Filho / Banca: Eduardo Miyashita / Resumo: Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below) / Doutor
86

Efeito de tratamentos da superfície de união e materiais reembasadores na resistência ao impacto de resina para base de prótese /

Perez, Luciano Elias da Cruz. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Ana Cláudia Pavarina / Banca: Luiz Antonio Pessan / Resumo: Este estudo avaliou o efeito de tratamentos da superfície de união e de materiais reembasadores na resistência ao impacto de uma resina para base de prótese. Corpos-de-prova foram confeccionados com a resina Lucitone 550 (60x6x2 mm) e reembasados (2 mm) com o mesmo material (L) ou com as resinas para reembasamento imediato Tokuso Rebase (TR) e Ufi Gel Hard (UH). Para o material L, as superfícies de união permaneceram sem tratamento (L/L/ST) ou foram tratadas com o monômero da resina L (metil metacrilato) for 180 segundos (L/L/M). Quando o reembasamento foi realizado com os reembasadores imediatos, os tratamentos de superfície consistiram de aplicação dos agentes adesivos fornecidos pelos fabricantes (L/TR/A - diclorometano e L/UH/A - diclorometano e 2-hidroxietil metacrilato) ou tratamento com o monômero da resina L seguido pelos adesivos (L/TR/MA e L/UH/MA). Corpos-de-prova do material L intacto (60x6x4 mm) também foram confeccionados para se determinar a resistência ao impacto dessa resina. Um total de 140 corpos-de-prova foi confeccionado, sendo 20 para cada condição experimental. Para metade dos corpos-de-prova, os entalhes foram realizados na largura, na superfície correspondente ao material reembasador, com profundidade de 0,8 mm, permanecendo 3,2 mm de material intacto (E1). Para os corpos-de-prova restantes, o entalhe foi realizado na espessura, envolvendo tanto o material reembasador como a resina de base, com profundidade de 1,2 mm (E2), permanecendo 4,8 mm de material intacto. Todos os entalhes, em forma de V, foram realizados na área central do comprimento dos corpos-de-prova. O teste utilizado foi do tipo Charpy, com pêndulo de 0,5 J e distância de 50 mm entre os suportes. Os resultados (kJ/ m2) de cada entalhe foram analisados, separadamente, utilizando-se ANOVA e teste de ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of surface treatments and reline materials on the impact strength of a denture base acrylic resin. Specimens were made using Lucitone 550 resin (60x6x2 mm) and relined (2 mm) with the same material (L) or with the hard chair-side reline resins Tokuso Rebase (TR) and Ufi Gel Hard (UH). For material L, the bond surfaces remained untreated (L/L/ST) or were wetted with resin L monomer (methyl methacrylate) for 180 seconds (L/L/M). When the relining was made with the hard reline materials, the surface treatments consisted of coating with the bonding agents supplied by the manufacturers (L/TR/A - dichloromethane and L/UH/A - dichloromethane and 2-hydroxyethyl methacrylate) or wetting with the resin L monomer followed by bonding agents application (L/TR/MA and L/UH/MA). Material L intact specimens (60x6x4 mm) were also made to determine the impact strength of the bulk resin. A total of 140 specimens were made, 20 for each experimental condition. Half of the specimens were notched across the width to a depth of 0.8 mm, leaving an effective depth under notch of 3.2 mm (E1). For the remaining specimens, the notch was cut across the thickness to a depth of 1.2 mm (E2) leaving an effective depth under notch of 4.8 mm. All the V-notches were machined at the midpoint of the length of the specimens. Impact tests were carried out on a Charpy type pendulum impact tester (0.5 J pendulum; distance between supporting points - 50 mm). Results (kJ/ m2) from each notch depth were analyzed separately using one-way ANOVA and Tukey's HSD tests (a = .05). No significant differences were noted among the mean impact values of L (1.39 kJ/ m2), L/L/ST (1.28 kJ/ m2) and L/L/M (1.20 kJ/ m2) specimens with the E1 notch (P>.05). Similar results were observed (P>.05) for the specimens with the E2 notch (L - 1.00 kJ/ m2; L/L/ST - 0.93 kJ/ m2; ...(Complete abstract, click electronic access below) / Mestre
87

Influência dos sistemas de retenção e da inclinação do rebordo residual em casos de próteses conjugadas Classe I mandibular : análise da distribuição das tensões pelo método da fotoelasticidade /

Ferraço, Renato. January 2009 (has links)
Resumo: A reabilitação de pacientes classe I de Kennedy mandibular através de Prótese Parcial Removível é de difícil resolução devido a diferença de resiliência existente entre o ligamento periodontal dos dentes suportes e a mucosa do rebordo residual. A inclinação do rebordo residual no sentido sagital pode influenciar na distribuição das tensões transmitidas pela incidência de cargas em próteses parciais removíveis de extremidade livre associadas a próteses parciais fixas. Na associação da prótese parcial removível com próteses parciais fixas, o profissional tem como alternativa aos grampos tradicionais, o uso de encaixes extra-coronários que podem melhorar a estética e o funcionamento biomecânico do conjunto. Desse modo, o objetivo desse estudo foi avaliar a característica da distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas; (2) sistema ASC-52; (3) sistema ERA; e (4) encaixe de semi-precisão Score-PD, pela metodologia da fotoelasticidade. E, analisar a distribuição de tensões em próteses parciais removíveis mandibulares de extremidade livre associadas a próteses parciais fixas nos dentes suporte com diferentes sistemas de retenção: (1) grampo por ação de pontas e (2) sistema ERA, variando duas inclinações de rebordo residual: (1) horizontal e (2) descendente distal. Cargas axiais de 100N foram aplicadas sobre os dentes das próteses parciais removíveis. As imagens das aplicações foram capturadas e a distribuição das tensões foi avaliada, pela formação das franjas fotoelásticas. No primeiro estudo, a prótese com encaixes de semi-precisão produziu os maiores níveis de tensão na região de ápice, entre as raízes dos últimos dentes suporte e na porção mais distal do rebordo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The rehabilitation of patients mandibular class I of Kennedy through Removable Partial Denture is difficult to solve because the difference in strength between the periodontal ligament of the abutment teeth and the residual ridge mucosa. The inclination of the residual ridge towards sagital may influence the distribution of stresses transmitted by the incidence of loads in distal extension removable partial dentures associated with fixed partial dentures. In association removable partial denture - fixed partial dentures, the professional has as alternative to the traditional clasps, the use of extra-coronary attachments that can improve the aesthetics and the biomechanics. Therefore, the objective of this study was to evaluate the characteristic distribution of tensions in mandibular distal extension removable partial dentures (1) "I" bar clasps, (2) ASC-52system, (3) ERA system, and (4) semi-precision Score-PD system, by the methodology of photoelasticity. And, analyze the distribution of tensions in mandibular distal extension removable partial dentures associated to the fixed partial dentures in the abutment teeth with different retention systems: (1) "I" bar clasps and (2) ERA system, ranging from two inclinations residual ridge: (1) horizontal and (2) distal descending. Axial loads of 100N were applied on the teeth of removable partial dentures. The images of the applications were captured and distribution of stress was assessed by the formation of the photoelastic fringes. In the first study, the prosthesis with semi-precision attachment produced the highest levels of tension in the region of apex, between the roots of the abutment teeth and in the more distal portion of the residual ridge. The prostheses with resilient attachments showed the largest fringes formations in the cervical-distal of the last abutment tooth. In the second study, horizontal ridge presented... (Complete abstract click electronic access below) / Orientador: Eduardo Piza Pellizzer / Coorientador: Stefan Fiuza de Carvalho Dekon / Banca: Marcelo Coelho Goiato / Banca: Fellippo Ramos Verri / Mestre
88

Candidose associada ao uso de prótese total superior: avaliação demográfica, clínica e microscópica / Candidosis associated with the use of maxillary complete denture: demographic, clinical and microscopic evaluation

Erika Martins Pereira 03 April 2007 (has links)
A estomatite por dentadura representa um processo inflamatório na mucosa oral em contato com a resina acrílica da prótese total ou parcial removível, sendo sua etiologia multifatorial, associada com fatores locais e sistêmicos, incluindo a presença de Candida albicans. O presente trabalho teve como objetivo a realização de uma análise demográfica, clínica e microscópica da candidose, associada ao uso da prótese total superior, nas formas atrófica, hiperplásica papilar e associada à hiperplasia fibrosa inflamatória. Para este fim, as amostras dos arquivos do laboratório de Anatomia Patológica do Departamento de Estomatologia - Área de Patologia - da Faculdade de Odontologia de Bauru, da Universidade de São Paulo, foram avaliadas microscopicamente, por meio das colorações de Hematoxilina e Eosina, Grocott de prata e Periodic Acid Schiffer (PAS), em comparação à mucosa normal de palato, oriunda de pacientes não usuários de prótese total ou removível superior. Foram resgatadas todas as informações contidas nas fichas clínicas correspondentes às amostras. As amostras de candidose bucal, independente do grupo, foram provenientes principalmente de indivíduos idosos, com médias variando de 51 a 60 anos, do gênero feminino e raça branca. Em alguns casos, o diagnóstico clínico da estomatite por dentadura atrófica pode ser difícil, necessitando de biópsia para confirmação. As lesões de hiperplasia papilar são removidas cirurgicamente com mais freqüência que aquelas de estomatite por dentadura atrófica, sendo geralmente reconhecidas pelo profissional clínico como hiperplasia fibrosa inflamatória. A candidose nas hiperplasias fibrosas inflamatórias não apresenta sinais clínicos exclusivos da sua presença; assim, torna-se improvável a suspeita clínica desta associação. De forma diferente da mucosa normal, microscopicamente, na maioria dos casos de candidose bucal, observaram-se revestimento epitelial hiperplásico com cristas alongadas, algumas em forma de tubo de ensaio, com freqüentes áreas de ausência de queratina, pequenos focos de reação liquenóide e de microabscessos, bem como extensas áreas de hiperplasia pseudoepiteliomatosa. Somente a hiperplasia papilar apresentou cristas epiteliais bífidas, revelando ainda maior freqüência de pérolas córneas-like e cristas em forma de tubo de ensaio, quando comparada com as outras formas de candidose bucal. O tecido conjuntivo fibroso subjacente, na candidose bucal, revelou intenso a moderado infiltrado inflamatório mononuclear predominante na lâmina própria e região perivascular. Não se observou marcação fúngica por meio das colorações especiais Grocott de prata e PAS. Assim, o diagnóstico microscópico da candidose bucal não deve depender da visualização do fungo nas camadas mais superficiais do revestimento epitelial. / Denture stomatitis is an inflammatory process affecting the oral mucosa in contact with acrylic resin of complete dentures or removable partial dentures. The disease has a multifactorial etiology, associate with local and systemic factors, including the presence of Candida albicans. The present study aimed to conduct a demographic, clinical and microscopic analysis of candidosis associated with the use of maxillary complete denture, in both atrophic and papillary hyperplastic forms and associated with inflammatory fibroepithelial hyperplasia. For that purpose, specimens from the files of the Anatomical Pathology Laboratory at the Department of Stomatology, Bauru Dental School, University of São Paulo, were microscopically reviewed in sections stained with hematoxylin and eosin (HE), Grocott\'s methenamine silver and periodic acid-Schiff (PAS), and compared to normal palatal tissues obtained from non-denture wearers. Clinical information was obtained and selected from clinical records. Regardless of the group, the specimens of oral candidosis were mainly obtained from aged individuals, with average age of 51 to 60 years, especially females and white individuals. In some cases, the clinical diagnosis of the atrophic denture stomatitis can be difficult and requires biopsy for confirmation. Papillary hyperplasia lesions are removed more frequently than atrophic denture stomatitis lesions, since they are generally recognized by clinicians as inflammatory fibroepithelial hyperplasia. Candidosis in inflammatory fibroepithelial hyperplasia does not present exclusive clinical signs of its presence; thus, clinical suspicion of this association is improbable. Different from the normal mucosa, microscopically, most cases of oral candidosis present hyperplastic epithelial lining with elongated rete pegs, some with \"test tube\" aspect, with frequent areas of absence of keratin, small foci of lichenoid reaction and microabscesses, as well as extensive areas of pseudoepitheliomatous hyperplasia. Only papillary hyperplastic lesions exhibited bifid rete pegs, besides high frequency of keratin pearls-like and long \"test tube\" rete pegs, when compared with the other forms of oral candidosis. The connective tissue underlying the oral candidosis presented moderate to intense mononuclear inflammatory infiltrate, predominantly at the lamina propria and perivascular region. Fungal hyphae and yeasts were not identified by special staining with Grocott\'s methenamine silver and (PAS). Thus, the microscopic diagnosis of oral candidosis should not depend on the visualization of fungal hyphae and yeasts at the most superficial layers of epithelial li pegs, when compared with the other forms of oral candidosis. The connective tissue underlying the oral candidosis presented moderate to intense mononuclear inflammatory infiltrate, predominantly at the lamina propria and perivascular region. Fungal hyphae and yeasts were not identified by special staining with Grocott\'s methenamine silver and (PAS). Thus, the microscopic diagnosis of oral candidosis should not depend on the visualization of fungal hyphae and yeasts at the most superficial layers of epithelial lining.
89

Avaliação in vitro da ação do hipoclorito de sódio e de pastilhas efervescentes quanto à alteração de cor em resinas acrílicas termopolimerizáveis e de microondas / In vitro evaluation of sodium hypochlorite and effervescent tablets actionregarding color alteration of heat and microwave-polymerized acrylic resins

Amanda Peracini 10 July 2008 (has links)
O objetivo deste estudo foi avaliar a alteração de cor de resinas acrílicas termopolimerizáveis (convencional e de microondas) após imersões em soluções químicas higienizadoras de próteses totais em diferentes períodos de tempo. Foram obtidos padrões em cera (15mm de diâmetro e 4mm de espessura), a partir de uma matriz de teflon, que foram incluídos em muflas convencionais e para microondas. Após a eliminação da cera, as resinas foram manipuladas, prensadas e polimerizadas segundo as instruções dos fabricantes. Foram confeccionados 200 corpos-de-prova, 100 de cada marca comercial das resinas Lucitone 550 (L) e Onda Cryl (OC), os quais foram imersos nas soluções: A)Água destilada-3 min.; B)Bony Plus -3 min.; C)Água destilada-5 min.; D)Corega Tabs-5 min.; E)Água destilada-20 min.; F)Hipoclorito de sódio a 0,5%-20 min.; G)Hipoclorito de sódio a 1%-20 min.; H)Água destilada-8 horas; I)Hipoclorito de sódio a 0,5%-8 horas; J)Hipoclorito de sódio a 1%-8 horas. A alteração de cor foi avaliada empregando-se um espectrocolorímetro (Color Guide 45/0 BYK-Gardner) antes e após a simulação de 180 dias de imersão. Os resultados foram comparados por meio da análise de variância (ANOVA) para dois fatores, seguida pelo teste de Student-Newman Keuls, com nível de significância de 0,05. Para correlacionar as diferenças de cor para o ambiente clínico, os dados foram calculados de acordo com as unidades da National Bureau of Standards (NBS). Os resultados mostraram que a resina Lucitone 550 (ΔE = 0,47±0,18) apresentou-se mais estável que a Onda-Cryl (ΔE = 0,53±0,31). Para ambas as resinas, as pastilhas, os hipocloritos por 20 minutos (0,5% e 1%) e por 08 horas (0,5%) não provocaram alterações maiores que seus respectivos controles (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). As soluções de hipoclorito a 1% (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) causaram maiores alterações que seus respectivos controles. As soluções empregadas por 08 horas (água e Hipocloritos a 0,5% e 1%) provocaram alterações classificadas como leves, segundo o sistema NBS. Os achados deste estudo revelaram que as pastilhas efervescentes, quando usadas de acordo com as instruções dos fabricantes, e o hipoclorito de sódio (0,5% e 1%) por 20 minutos apresentaram menores valores de alteração de cor nas resinas acrílicas após um período de uso simulado de 180 dias. Médias mais elevadas foram obtidas quando um regime de 8 horas foi simulado. / The aim of this study was to evaluate color alteration of heat-polymerized acrylic resins (conventional and microwave-polymerized), after immersion in chemicals solutions of denture cleansers for different periods of time. Wax patterns were obtained (15 mm in diameter and 4 mm thickness) from a teflon matrix and were invested in metallic or microwavable flasks. The wax had been eliminated and the resins were mixed, packed and polymerized according to the manufacturers instructions. Two hundred specimens were made, 100 specimens of each commercial resin Lucitone 550 (L) e Onda Cryl (OC), which were immersed in the solutions: A)Distilled water-3 min.; B)Bony Plus-3 min.; C)Distilled water-5 min.; D)Corega Tabs-5 min.; E) Distilled water -20 min.; F) 0,5% Sodium Hypochlorite-20 min.; G) 1% Sodium Hypochlorite-20 min.; H)Distilled water-8 hours; I)0,5% Sodium Hypochlorite-8 hours; J)1% Sodium Hypochlorite -8 hours. Color alteration was assessed by a spectrocolorimeter (Color Guide 45/0 (BYKGardner) before and after 180 days simulation. The results were analyzed statistically by a two-way analysis of variance (ANOVA), and Student Newman-Keuls test, with significance level of 0.05. To relate the color differences to a clinical environment, the data were quantified by National Bureau of Standards (NBS) units. The results showed that the resin Lucitone 550 (ΔE=0,47±0,18) was more stable than the resin Onda-Cryl (ΔE=0,53±0,31). For both resins, the tablets, the hypochlorite by 20 minutes (0,5% e 1%) and by 8 hours (0,5%) did not produce higher alterations than the respective controls (L-A: 0,27 ±0,10; L-B: 0,44±0,21; L-C: 0,48±0,21; L-D: 0,46±0,13; L-E: 0,29±0,07; L-F: 0,37±0,08; L-G: 0,47±0,10; L-H: 0,61±0,11; L-I: 0,55±0,10; OC-A: 0,22±0,08; OC-B: 0,43±0,32; OC-C: 0,65±0,35; OC-D: 0,41±0,11; OC-E: 0,31±0,11; OC-F: 0,29±0,07; OC-G: 0,37 ±0,11; OC-H: 0,78±0,10; OC-I: 0,79±0,08). The 1% hypochlorite solutions (L-J: 0,74±0,09; OC-J: 1,06 ±0,13) produced higher alterations than the respective controls. The solutions employed by 8 hours (water and 0,5% and 1% hipochlorite) produced alterations classified as slight, according to the NBS system. The findings of this study showed that the effervescent tablets, used according to the manufacturer´s instructions, and the sodium hypochlorite (0,5% and 1%) used by 20 minutes presented lower values of color alterations in acrylic resins after a period of 180 days simulation. Higher mean averages were obtained when a period of 8 hours was simulated.
90

Avaliação do posicionamento de caninos superiores permanentes na fase da dentadura mista em relação à largura do arco dentário e ao espaço na região anterior / Evaluation of the maxillary canines position in mixed-dentition and width and anterior space relationship

Selma Sano Suga 19 March 2008 (has links)
Este estudo avaliou o posicionamento de caninos superiores permanentes em relação à largura do arco dentário superior e ao espaço na região anterior em pacientes na fase da dentadura mista. Foram analisados radiografias panorâmicas e modelos de estudo pré-tratamento de pacientes sem caninos deslocados (n = 68; 34 do gênero masculino; 34 do gênero feminino). A amostra foi dividida em idade e gênero. A largura do arco dentário e o espaço na região anterior entre os incisivos permanentes foram medidos. A posição e a inclinação do canino na radiografia panorâmica foram avaliadas em relação à linha mediana. Os resultados deste estudo mostram que não houve diferenças no posicionamento dos caninos permanentes em relação às variáveis analisadas. A média da angulação do canino superior em relação à linha mediana foi 6,2o e 10o para o gênero feminino e 9,2o e 11o para o masculino, respectivamente para o lado direito e esquerdo. / This study investigated the correlation between maxillary dental arch width, anterior space and the position of canines in patients during the mixed-dentition stage. Pretreatment Panoramic radiographs and dental casts were evaluated of randomly selected patients in the mixed dentition without maxillary canines displaced (n = 68; male, 34; female, 34). This sample was matched according to sex and age. Arch widths between the maxillary canines deciduous and anterior space between permanent incisors were measured and recorded. The position and inclination of canine on panoramic radiography was investigated. The results of this study showed that there are similarities in the position of the permanent canines in all cases and in both gender. The average of the canine\'s angulation to the mid-sagital plane was 6,2o and 10o for female and 9,2o and 11o for male, respectively to the right and left side.

Page generated in 0.0406 seconds