• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 8
  • 2
  • Tagged with
  • 38
  • 38
  • 26
  • 25
  • 14
  • 12
  • 12
  • 12
  • 10
  • 9
  • 9
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Análise comparativa da distribuição de tensões em incisivo central superior, restaurado com diferentes sistemas de pinos intra-radiculares

Oliveira, Luana Cristina Araújo de [UNESP] 25 February 2002 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:08Z (GMT). No. of bitstreams: 0 Previous issue date: 2002-02-25Bitstream added on 2014-06-13T18:20:14Z : No. of bitstreams: 1 oliveira_lca_me_arafo.pdf: 6998958 bytes, checksum: 84e0be5fadd238e2fd976b220d028362 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho é proposto analisar a distribuição de tensões produzidas na dentina radicular do incisivo central superior restaurado com diferentes sistemas de pinos intra-radiculares, através dos Métodos de Fotoelasticidade e Elementos Finitos. Esta análise foi realizada para os seguintes sistemas de pinos intra-radiculares: fibra de carbono, fibra de vidro, zircônio, aço inoxidável, titânio e metálico fundido (Liga de Cu-Al), o dente hígido foi utilizado como controle. Em ambos método foi construído um modelo bidimensional representativo do incisivo central superior e aplicada uma carga de 100 N no terço incisal da região palatina com um inclinação de 45º em relação aoa longo eixo do dente. Os resultados foram expressos em função da Tensão de Von Mises - Se e Sy, e valor da Ordem de Franja, para o Método de Elementos Finitos e Fotoelasticidade, respectivamente. Através da análise dos resultados, concluiu-se que houve diferenças significativas na distribuição de tensão entre os seis sistemas de pinos testados, sendo que, os pinos de zircônio, aço inoxidável, titânio e metálico fundido, promoveram uma alta concentração de tensões na região conduto radicular ao longo da interface pino/dentina. Nos pinos de fibra de vidro e fibra de carbono houve uma distribuição de tensões uniforme ao longo de toda a superfície radicular, não se verificou áreas de concentração de tensões produzidas por estes sistemas de pinos. Os pinos de zircônio, aço inoxidável, titânio e metálico fundido apresentaram propriedades mecânicas diferentes da estrutura dental, promovendo alterações significativas no comportamento mecânico do dente. De acordo com estes resultados, concluímos que os pinos não metálicos atendem de maneira satisfatória os requisitos necessários para proporcionarem um comportamento mais semelhante à estrutura dental, a compatibilidade... . / This work proposes a study about the distribution of mechanical stresses in the radicular dentin of restored with different posts systems, by means of the photoelastic and the finite element techniques. This analysis is conducted for the following posts systems: carbon fiber, fiberglass, zirconium, stainless steel, titanium and cast metal (Cu-Al alloy) and the healthy tooth (control). For this purpose, representative two-dimensional models of the central upper incisor are built for both methods. These models are subject to a 100N load applied at the tip of the crown, at 45º from the axle along the tooth. The results are expressed in terms of the Von Mises and Sy stresses and the fringe order, for the finite element and photoelastic methods, respectively. Through the analysis of these results, it can be concluded that significant stress distribution differences arise between the six different pin systems tested, so that those made of zirconium, stainless steel, titanium and cast metal produced high stress concentration at the post/dentin interface region. In the cases of the carbon fiber and fiberglass pins, on the other hand, the stress distribution along the radicular surface is uniform, lacking stress concentration areas. The zirconium, stainless steel, titanium and cast metal pins present mechanical properties which are different from those of the tooth structure, resulting in significant alterations over the mechanical behavior of the dental structure. The non-metallic pins comply more satisfactorily with the requirements necessary to provide a mechanical behavior more similar to that of the dental structure, the compatibility among the mechanical properties found in these system and the dentin providing a biomimetic behavior, reducing the risk of failure or root fractures.
12

Análise comparativa da distribuição de tensões em incisivo central superior, restaurado com diferentes sistemas de pinos intra-radiculares /

Oliveira, Luana Cristina Araújo de. January 2002 (has links)
Resumo: Neste trabalho é proposto analisar a distribuição de tensões produzidas na dentina radicular do incisivo central superior restaurado com diferentes sistemas de pinos intra-radiculares, através dos Métodos de Fotoelasticidade e Elementos Finitos. Esta análise foi realizada para os seguintes sistemas de pinos intra-radiculares: fibra de carbono, fibra de vidro, zircônio, aço inoxidável, titânio e metálico fundido (Liga de Cu-Al), o dente hígido foi utilizado como controle. Em ambos método foi construído um modelo bidimensional representativo do incisivo central superior e aplicada uma carga de 100 N no terço incisal da região palatina com um inclinação de 45º em relação aoa longo eixo do dente. Os resultados foram expressos em função da Tensão de Von Mises - Se e Sy, e valor da Ordem de Franja, para o Método de Elementos Finitos e Fotoelasticidade, respectivamente. Através da análise dos resultados, concluiu-se que houve diferenças significativas na distribuição de tensão entre os seis sistemas de pinos testados, sendo que, os pinos de zircônio, aço inoxidável, titânio e metálico fundido, promoveram uma alta concentração de tensões na região conduto radicular ao longo da interface pino/dentina. Nos pinos de fibra de vidro e fibra de carbono houve uma distribuição de tensões uniforme ao longo de toda a superfície radicular, não se verificou áreas de concentração de tensões produzidas por estes sistemas de pinos. Os pinos de zircônio, aço inoxidável, titânio e metálico fundido apresentaram propriedades mecânicas diferentes da estrutura dental, promovendo alterações significativas no comportamento mecânico do dente. De acordo com estes resultados, concluímos que os pinos não metálicos atendem de maneira satisfatória os requisitos necessários para proporcionarem um comportamento mais semelhante à estrutura dental, a compatibilidade... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: This work proposes a study about the distribution of mechanical stresses in the radicular dentin of restored with different posts systems, by means of the photoelastic and the finite element techniques. This analysis is conducted for the following posts systems: carbon fiber, fiberglass, zirconium, stainless steel, titanium and cast metal (Cu-Al alloy) and the healthy tooth (control). For this purpose, representative two-dimensional models of the central upper incisor are built for both methods. These models are subject to a 100N load applied at the tip of the crown, at 45º from the axle along the tooth. The results are expressed in terms of the Von Mises and Sy stresses and the fringe order, for the finite element and photoelastic methods, respectively. Through the analysis of these results, it can be concluded that significant stress distribution differences arise between the six different pin systems tested, so that those made of zirconium, stainless steel, titanium and cast metal produced high stress concentration at the post/dentin interface region. In the cases of the carbon fiber and fiberglass pins, on the other hand, the stress distribution along the radicular surface is uniform, lacking stress concentration areas. The zirconium, stainless steel, titanium and cast metal pins present mechanical properties which are different from those of the tooth structure, resulting in significant alterations over the mechanical behavior of the dental structure. The non-metallic pins comply more satisfactorily with the requirements necessary to provide a mechanical behavior more similar to that of the dental structure, the compatibility among the mechanical properties found in these system and the dentin providing a biomimetic behavior, reducing the risk of failure or root fractures. / Orientador: Maria Salete Machado Cândido / Coorientador: Sônia Aparecida Goulart Oliveira / Banca: Jesuânia Maria Guardiero Azevedo Pfeifer / Banca: Welingtom Dinelli / Mestre
13

Efeitos dos protocolos de irrigação durante o preparo do espaço protético sobre a adesão de pino de fibra na dentina radicular /

Ramos, Anna Thereza Peroba Rezende. January 2019 (has links)
Orientador: Milton Carlos Kuga / Resumo: Objetivo: avaliar a influência do protocolo de irrigação: sem irrigação (WI), com irrigação alternada (AI) ou com a irrigação contínua (CI), em diferentes situações que influência diretamente na qualidade de adesão do pino de fibra de vidro ao substrato dentinário, para isso analisamos presença de resíduos, quantidade de túbulos dentinários abertos; resistência de união do sistema de cimentação na dentina; padrão de fratura da adesão e penetrabilidade dentinária. Material e métodos: raízes de incisivos bovinos foram obturadas, submetidas ao preparo para pino de fibra e distribuídas em grupos, de acordo com o protocolo de irrigação: (WI); (AI) e (CI), e o cimento utilizado (Allcem Core RelyX Ultimate). Após a conclusão do preparo, as raízes foram subdivididos em grupos (n=10), onde foram avaliadas em MEV para avaliar a presença de resíduos, em MEV para incidência de túbulos dentinários abertos na superfície dentinária, Microscopia Confocal a laser para avaliar a penetrabilidade, Estereomicroscopio para avaliar o padrão de fratura. Pinos de fibra foram cimentados com sistema de cimentação (RelyX Ultimate) nos demais espécimes (n=10) e submetidos ao teste de push-out e avaliação do padrão de fratura. Resultados: Em todas as avaliações os grupos que tiveram irrigação contínua no preparo do pino apresentaram valores significativamente melhores em relação ao que estava sendo analisado em especifico (P > 0,05). Os terços cervical e médio também apresentaram melhores resultado compar... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective: The aim of this study was to assess the influence of the irrigation protocol: without irrigation (WI), alternate irrigation (AI) or continuous irrigation (CI), in different situations that directly influence the adhesion quality of the fiber post to the dentin substrate, for this we analyzed the residues presence, the number of open dentinal tubules; bonding strength of the cementation system in dentin; adhesion failure pattern and dentin penetrability. Material and methods: roots of bovine were obturated, submitted to preparation for fiber post and distributed in groups, according to the irrigation protocol: (WI); (AI) and (CI), and the cement used (Allcem Core RelyX Ultimate). After the preparation was completed, the roots were subdivided into groups (n = 10), where they were evaluated in SEM to evaluate the residues, in SEM for incidence of open dentinal tubules on the dentin surface, Confocal laser microscopy to evaluate the penetrability, stereomicroscope to evaluate the failure pattern. Posts were cemented with cementation system (RelyX Ultimate) in the other specimens (n = 10) and submitted to the push-out test and evaluation of the failure pattern. Results: In all evaluations, the groups that had continuous irrigation in the preparation of the post showed significantly better values than the one being analyzed in specific (P> 0.05). The cervical and middle thirds also presented better results compared to the apical thirds. Conclusion: WI caused a greater p... (Complete abstract click electronic access below) / Doutor
14

Avaliação in vitro da resistência à fratura de raízes dentais fragilizadas reabilitadas com núcleos de preenchimento associados a pinos de fibra de vidro / In vitro evaluation of fracture strength of dental weakened roots rehabilitated with cores associated with fiberglass posts

Clavijo, Érika Manuela Asteria, 1986- 22 August 2018 (has links)
Orientador: Caio Cezar Randi Ferraz / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T04:14:56Z (GMT). No. of bitstreams: 1 Clavijo_ErikaManuelaAsteria_M.pdf: 12544846 bytes, checksum: e5ccc90481f71cac564a4038b3f3cc5f (MD5) Previous issue date: 2013 / Resumo: Este trabalho avaliou in vitro a resistência à fratura de raízes de incisivos bovinos com 3 espessuras de dentina, nas quais, foram cimentados pinos de fibra de vidro com e sem reembasamento com resina composta. 180 raízes bovinas foram padronizadas em 14 mm. Os espécimes foram divididos em 3 grupos de acordo com a espessura da parede dentinária: Grupo1 (G1) = 1 milímetro de espessura (n=60); Grupo 2 (G2): 2 milímetros de espessura (n=60) e Grupo Controle (G3)= raízes sem fragilização (n=60). Os 4 mm apicais dos canais radiculares foram selados com Coltosol® e as raízes foram inseridas em um material de moldagem a base de poliéter e resina acrílica para simulação ligamento periodontal. Em seguida, cada grupo foi subdividido em 2 sub-grupos (n=30): raízes que receberam cimentação de pino de fibra de vidro somente (P) e raízes que receberam cimentação com pino reembasado com resina composta (PR). O cimento Relyx ARC ® foi utilizado para cimentação dos retentores intrarradiculares. Os corpos-de-prova foram submetidos ao teste de resistência à fratura em máquina de ensaio com aplicação de carga em ângulo de 135º com o longo eixo do espécime por lingual (n= 90) e por vestibular (n=90). Os valores foram registrados em Newtons (N) submetidos à Análise de variância e teste de Tukey. As fraturas foram avaliadas em microscópio clínico e classificadas quanto à possibilidade de reabilitação pós-fratura em favoráveis e desfavoráveis. O dado obtido deste estudo mostrou não haver diferença estatística significativa entre os grupos avaliados (p>0,05) com relação ao teste de resistência a fratura com forças aplicadas por vestibular. Por lingual, o grupo G1PR apresentou diferença estatística quando comparado aos grupos G2P e G3P (p<0,05). No teste por vestibular, os espécimes do grupo PR que tiveram fratura radicular, tiveram a incidência de fraturas favoráveis em G1: 87,5%, G2: 80% e G3: 83,3%. Por Lingual, o grupo G3PR apresentou fraturas apenas nos núcleos de preenchimento, não havendo fraturas em raiz. O G1PR e o G1P apresentaram 80% dos espécimes com fraturas radiculares, das quais 91,67% e 66,67% foram classificadas como favoráveis. As diferentes espessuras de dentina não interferiram na resistência à fratura, sugerindo que dentes com paredes fragilizadas são passíveis de serem restaurados. No ensaio realizado por Lingual G1PR apresentou maior resistência a fratura. A maioria das fraturas radiculares, ocorridas nas raízes restauradas com pinos de fibra de vidro e núcleos de preenchimento em resina composta, foram consideradas favoráveis / Abstract: The aim of this is study was to evaluate in vitro fracture strength of weakened roots with 3 thicknesses of dentin, in which were cemented fiberglass posts and anatomic fiber posts (fiberglass post with composite resin). 180 freshly extracted bovine incisors were used. The crowns and apices of were sectioned to create the samples with 14 mm of root. The samples were divided into 3 groups: Group 1 (G1) = dentin walls with 1 mm thickness (n = 60), Group 2 (G2): dentin walls with 2 mm thickness (n = 60) and Control Group (G3) = roots without weakening (n = 60). 4mm apical root canal was sealed with Coltosol ®, and the samples were inserted into artificial periodontal ligament with an impression material and acrylic resin. Then, each group was divided into two subgroups (n = 30) that received roots luting of glass fiber post only (P) and roots receiving cementing anatomic fiber post (PR). The cement Relyx ARC ® was used for cementation of intracanal retainers. The samples were tested for fracture strength in a universal testing machine with load application angle of 135 degrees with the long axis of the specimen by palate (n = 90) and vestibular (n = 90). The values were recorded in Newtons (N) and statistically analyzed by ANOVA. The fractures were evaluated in clinical microscope and classified after fracture as favorable and unfavorable. Results from this study showed no statistically significant difference among the groups (p > 0.05) to the fracture strength test with forces applied by vestibular. On the lingual face there was statistically significant difference between groups G1PR and G1P when compared to CPR (p< 0.05). On the vestibular face the specimens restored with anatomic post that had root fracture from groups G1, G2 and G3 had the incidence of favorable fractures in 87.5%, 80% and 83.3% of the cases. By lingual the CPR group had fractures only in filling cores, with no root fractures. The G1PR and G1P showed 80% of specimens with root fractures, of which 91.67% and 66.67% were classified as favorable. The different thicknesses of dentin did not affect the fracture strength, suggesting that teeth with weakened walls are easily restorable. By Lingual. The anatomic post showed higher resistance to fracture. Most root fractures, when occur in teeth restored with fiberglass posts are considered favorable / Mestrado / Endodontia / Mestra em Clínica Odontológica
15

Efeito de inibidores da atividade proteolítica na resistência de união de pino de fibra de vidro à dentina radicular após 12 meses / Effect of proteolytic activity inhibitors on bond strength of glass-fiber post to radicular dentin up to 12 months

Chaves, Larissa Pinceli 19 August 2016 (has links)
O estabelecimento de uma camada híbrida adequada no canal radicular representa um dos principais desafios clínicos devido à dificuldade de acesso. Dessa forma, o uso de inibidores proteolíticos poderia tornar-se um recurso favorável. O objetivo deste estudo foi avaliar o efeito de inibidores proteolíticos na união de pino de fibra de vidro fixado com cimento adesivo, considerando os terços radiculares e tempos distintos, por meio da resistência de união (RU). Cento e quarenta e quatro raízes bovinas foram selecionadas e divididas em 6 grupos de tratamento, e redivididas em 3 subgrupos de acordo com os tempos de avaliação de 24 horas, 6 e 12 meses (n=8). Após o tratamento endodôntico e desobturação padronizados, as raízes foram cimentadas com pinos de fibra de vidro cônicos (Exacto/Angelus). As raízes foram tratadas com sistema adesivo convencional de três passos, Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) e cimento dual RelyX ARC/ 3M ESPE. Após prévia divisão, foram alocadas em grupos CN (Controle Negativo- sem pré tratamento associado), CP (Controle Positivo- com agentes ativador e catalisador), EDTA (ácido etilenodiamino tetra-acético a 17%), CHX (digluconato de clorexidina a 2%), E-5 (E- 64 a 5 M) e E-10 (E-64 a 10 M). Após 24 horas, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias de 1 mm de espessura (cervical, médio e apical), que foram armazenadas em saliva artificial para serem testadas. Todas as fatias foram submetidas ao teste de extrusão (push-out) na máquina de teste universal (Instron) com célula de carga de 50 N a 0,5 mm/min. Os dados foram analisados pelo teste de ANOVA a três critérios e comparações múltiplas com Tukey, ambos com p<0,05. Após 24 horas, não se observou diferenças entre os tratamentos. Após 6 meses, a CHX demonstrou melhor desempenho, cujo efeito não se prorrogou até os 12 meses. O uso de inibidores proteolíticos não foram capazes de preservar a resistência de união dos pinos intrarradiculares até o tempo de 12 meses. / The adequate establishment of hybrid layer in the root canal on bonding process is still a clinical challenge due to its hard access. Thus, the use of proteolytic inhibitors could become a favorable tool. The aim of this study was to evaluate the effect of proteolytic inhibitors in the bonding of a glass- fiber post fixed with a luting cement, regarding the root thirds and different times through the bond strength. One hundred and forty four bovine roots were selected and divided into 6 treatment groups, and subdivided according to the time of evaluation of 24 hours, 6 and 12 months (n=8). After endodontic treatment and standardized removal procedure, the roots were cemented with tapered glass fiber posts (Exacto/ Angelus). The roots were treated with three-step etch-and-rinse adhesive system Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) and dual cement RelyX ARC/ 3M ESPE. After previous division, CN (negative- control without pre associated treatment), CP (Control positive- with activator and catalyst agents) EDTA (17% ethylenediaminetetraacetic acid) CHX (2% chlorhexidine digluconate) E-5 (5M E-64) and E-10 (10M E-64). After 24h, the roots were sectioned perpendicular to the long axis and identified according to third in 1mm thick slices (cervical, middle and apical), which were stored in artificial saliva to be tested. All slices were subjected to extrusion tests (push-out) in the universal test machine (Instron) at 50 N load cell at 0.5 mm/min. Data were analyzed with three-way ANOVA and multiple comparisons with Tukey test, both with p <0.05. After 24 hours, no differences were observed between treatments. After 6 months, CHX showed better performance, which did not last up 12 months. The proteolytic inhibitors performed differently in the bonding process over time; only CHX promoted inhibition at 6 months. The use of proteolytic inhibitors were not able to maintain the bond strength of intraradicular posts up time of 12 months.
16

Resistência à fratura de técnicas de colagem empregadas para restauração de dentes fraturados com ou sem tratamento endodôntico / Fracture strength of different techniques for re-attachment of teeth submitted or not to endodontic treatment

Scarpati, Alexander Otto Eduardo Kraul 28 September 2007 (has links)
O objetivo deste estudo foi comparar à resistência à fratura de três técnicas de colagem usadas para restaurar dentes fraturados hígidos e com tratamento endodôntico associado ou não a colocação de pino de fibra de vidro. Noventa incisivos humanos foram aleatoriamente divididos em três grupos de 30 dentes cada. No grupo A, os dentes não foram tratados endodonticamente, enquanto os dentes dos grupos B e C foram submetidos ao tratamento endodôntico, seguido de restauração da câmara pulpar com resina composta. Todos os dentes foram fraturados por uma carga axial aplicada na superfície vestibular para obter fragmentos dentais. Os dentes de cada grupo foram novamente subdivididos em três subgrupos: colagem simples [CS], chanfro vestibular [CV] e chanfro circunferencial [CC]). Antes da colagem dos fragmentos, pinos de fibra de vidro foram colocados nos dentes do grupo C. Todos os fragmentos dos dentes (grupos A, B e C) foram colados utilizando um cimento de dupla ativação (Duo- Link, Bisco Inc). No grupo CS, nenhum preparo adicional foi realizado após colagem, porém no restante dos dentes realizou-se uma canaleta vestibular (grupo CV) ou uma canaleta circunferencial ao redor da linha de colagem (CC) com aproximadamente 1,0 mm de profundidade. As canaletas foram restauradas com resina composta microhíbrida. Por fim, os espécimes foram submetidos a mesma carga axial no mesmo ponto pré-determinado. A resistência à fratura após o procedimento restaurador foi expressa em porcentagem de resistência do dente íntegro. Os dados foram submetidos a uma análise de variância de dois fatores (Grupo vs. Técnica de colagem) e teste de Tukey (?=0,05). Somente o fator principal Técnica de colagem foi estatisticamente significante (p<0,05). Nenhuma das técnicas de colagem empregadas conseguiu restabelecer a resistência à fratura do dente hígido. A confecção de uma canaleta vestibular e circunferencial proporcionaram uma recuperação de resistência similar (p>0,05) entre si e superior ao alcançado pela técnica de colagem simples (p<0,05). Concluiu-se que o uso de pino de fibra de vidro não é essencial para reforço da estrutura dental antes da colagem de fragmentos de dentes tratados endodonticamente. As técnicas de chanfro vestibular e chanfro circunferencial devem ser preferidas ao se realizar a colagem de fragmentos devido a maior recuperação da resistência do dente hígido em relação a técnica de colagem simples. / The aim of this study was to compare the fracture strength of three techniques used to reattach tooth fragments in sound and endodontically-treated fractured teeth either associated or not with fiber post placement. Ninety human lower incisors were randomly divided into three groups of 30 teeth each. In group A teeth were not subjected to endodontic treatment; while teeth from groups B and C were endodontically treated and the pulp chamber restored with a composite resin. All teeth were fractured by an axial load applied to the buccal area in order to obtain tooth fragments. Teeth from each group were divided again into three subgroups: bonded only [BO], buccal chamfer [BC] and circumferential chamfer [CC]). Before the re-attachment procedures, fiber posts were placed in teeth from group C. All teeth (groups A, B and C) had the fragments re-attached using a dual cure resin luting cement (Duo-Link, Bisco Inc., Itasca, IL). In the BO group, no additional preparation was made. Teeth from groups BC and CC groups had a 1.0 mm-depth chamfer placed in the fracture line either on buccal surface [group BC] or along the buccal and lingual surfaces [group CC]. Increments of microhybid composite resin were used in subgroups BC and CC to restore the chamfer. The specimens were loaded until fracture in the same pre-determined area. The force required to detach each fragment was recorded and a percentage of fracture strength recovery calculated for each tooth. The data was subjected to a two-way analysis of variance (Group vs. Re-attachment technique) and Tukey\'s test (?=0.05). Only the main factor Re-attachment technique was statistically significant (p<0.05). None of the techniques used for teeth re-attachment restored the fracture strength of the intact teeth. The placement of buccal and circumferential chamfer yielded statistically similar (p>0.05) fracture strength recovery, which was superior to the bonded only technique (p<0.05). The use of fiber post is not mandatory for the reinforcement of the tooth structure before reattachment of fragments in endodontically-treated teeth. When bonding a fractured fragment, the buccal or circumferential re-attachment techniques should be preferable in comparison with the simple re-attachment without any additional preparation.
17

Resistência de incisivos centrais superiores irrigados com EDTA e portadores de retentores intra-radicular.

Pineda, Ana Raquel Pineda January 2006 (has links)
71f. / Submitted by Suelen Reis (suziy.ellen@gmail.com) on 2013-04-23T13:53:14Z No. of bitstreams: 3 Biblioteca- Ana Raquel3.pdf: 296421 bytes, checksum: 7fbbfec8c50b5ea955fca6011a25673c (MD5) Biblioteca- Ana Raquel2.pdf: 393653 bytes, checksum: 73570d5c5d748db504cd3d04b5bb01b7 (MD5) Biblioteca- Ana Raquel1.pdf: 128471 bytes, checksum: f09e83f242a8a3cce146311a97024814 (MD5) / Approved for entry into archive by Rodrigo Meirelles(rodrigomei@ufba.br) on 2013-05-08T11:48:59Z (GMT) No. of bitstreams: 3 Biblioteca- Ana Raquel3.pdf: 296421 bytes, checksum: 7fbbfec8c50b5ea955fca6011a25673c (MD5) Biblioteca- Ana Raquel2.pdf: 393653 bytes, checksum: 73570d5c5d748db504cd3d04b5bb01b7 (MD5) Biblioteca- Ana Raquel1.pdf: 128471 bytes, checksum: f09e83f242a8a3cce146311a97024814 (MD5) / Made available in DSpace on 2013-05-08T11:48:59Z (GMT). No. of bitstreams: 3 Biblioteca- Ana Raquel3.pdf: 296421 bytes, checksum: 7fbbfec8c50b5ea955fca6011a25673c (MD5) Biblioteca- Ana Raquel2.pdf: 393653 bytes, checksum: 73570d5c5d748db504cd3d04b5bb01b7 (MD5) Biblioteca- Ana Raquel1.pdf: 128471 bytes, checksum: f09e83f242a8a3cce146311a97024814 (MD5) Previous issue date: 2006 / Foi realizado um estudo in vitro para avaliar a resistência de dentes anteriores tratados endodonticamente, que foram irrigados com EDTA 17%, pH 7,0 durante 1 e 3 minutos e portadores de retentor intra-radicular, fundido em liga de Níquel-Cromo. Foram utilizados 30 incisivos centrais superiores de dimensões semelhantes. As raízes foram instrumentadas pela técnica escalonada e a irrigação final foi feita com a solução em estudo. Posteriormente os retentores foram cimentados com fosfato de zinco e os corpos de prova levados à máquina de ensaio Instrom 1122, com velocidade de 0,5 mm/min, para ser submetidos a teste de compressão. Os resultados foram avaliados, usando-se a Análise de Variância (ANOVA), o Teste de Tukey, o teste t de Student e o teste de Kolmogorov-Smirnov, mostrando que houve diferença, estatisticamente significante (p= 0.014), entre o grupo irrigado com EDTA 1 min e o grupo irrigado com detergente. / Salvador
18

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro

Lima, Luiz Rafael Calixto [UNESP] 03 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:07Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-03Bitstream added on 2014-06-13T18:51:40Z : No. of bitstreams: 1 lima_lrc_me_arafo.pdf: 301269 bytes, checksum: e249a410590b65d0ca0f202c5160930d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... / The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey’s test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs.
19

Influência de soluções irrigadoras na resistência adesiva de pinos de fibra de vidro utilizando cimento resinoso: avaliação através do teste de push-out

Figueiredo, Mariana Diehl [UNESP] 01 June 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:24:37Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-06-01Bitstream added on 2014-06-13T20:12:41Z : No. of bitstreams: 1 figueiredo_md_me_sjc.pdf: 1643333 bytes, checksum: 28c65af70a60c705d107f1d4b9fc61c6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Atualmente, os pinos de fibra de vidro têm surgido como uma alternativa para restaurar dentes tratados endodonticamente. Entretanto, a perda da retenção do pino é uma das principais causas de falhas. Portanto, o objetivo deste estudo foi avaliar a resistência de união e o tipo de falha adesiva, em diferentes regiões da raiz, de pinos de fibra de vidro transparente cimentados no canal radicular com cimento de cura dual, variando-se a solução irrigadora utilizada durante o preparo dos canais, através do teste de push-out. Para o estudo, foram utilizados 30 dentes humanos, todos igualmente preparados. No momento da cimentação dos pinos, as soluções irrigadoras foram: solução de soro fisiológico, hipoclorito de sódio 2,5% e solução de clorexidina 2%; e o cimento resinoso utilizado foi de cura dual. Após a cimentação, os espécimes foram seccionados, obtendo-se 2 fatias de aproximadamente 2 mm cada, suas faces cervicais foram marcadas, e então, submetidas ao teste de push-out. Foram realizados os testes ANOVA e Tukey, com nível de significância de 5 %, para a análise do ensaio mecânico e realizada análise qualitativa do tipo de falha ocorrida. Pôde-se observar que o grupo irrigado com hipoclorito de sódio 2,5% apresentou menor valor da média de resistência adesiva (3,870 ± 3,799 MPa), comparado com o grupo da clorexidina 2% (4,215 ± 2,098 MPa) e com o grupo do soro (4,510 ± 1,186 MPa). Já em relação aos terços, a região média foi a que apresentou maior valor da média de resistência adesiva (4,803 ± 3,14 MPa) quando comparado com a região cervical (3,593 ± 1,717 MPa), porém não houve diferença estatística significante, nem entre as regiões e nem entre as soluções irrigadoras. A maioria das falhas ocorridas foram do tipo adesiva 70%, enquanto que 23,33% foram fraturas coesivas, e 6,66% foram do tipo mistas. Assim, é possível concluir que os... / Currently, the fiberglass posts have emerged as an alternative to restore endodontically treated teeth. However, the loss of retention of the pin is a major cause of failure. Therefore, the aim of this study was to evaluate and compare the bond strength of transparent fiberglass posts, using a dual cure cement, varying the irrigating solution used during the preparation of the root canals through the push-out test and then a qualitative analysis of types of adhesion failures was made by reading into a stereomicroscope. For the study, 30 human teeth were used, all equally prepared. At the time of cementation of the posts, the irrigating solutions were: normal saline solution, sodium hypochlorite 2.5%, and 2% chlorhexidine solution, and the resin cement used was dual-curing. After cementation, specimens were sectioned, yielding two slices of about 2 mm each, their cervical faces were marked, and then subjected to push-out test, the data obtained were analyzed by descriptive and inferential statistics. The tests performed were ANOVA and Tukey, with a significance level of 5% for the analysis of mechanical test, and the type of failure occurred was qualitatively evaluated. It could be observed that the group irrigated with sodium hypochlorite 2.5% showed the lowest mean bond strength (3.870 ± 3.799 MPa), compared with 2% chlorhexidine group (4.215 ± 2.098 MPa) and the normal saline solution group (4.510 ± 1.186 MPa). In relation to the thirds, the middle region showed the highest value of bond strength average (4.803 ± 3.14 MPa) compared with the cervical (3.593 ± 1.717 MPa), but differences were not statistically significant, nor between regions nor between irrigating solutions. Most failures were adhesive type 70%, while 23.33% were cohesive fractures, and 6.66% were mixed type. Thus, we conclude that the irrigation protocols evaluated in this study did not exert effects on the bond ... (Complete abstract click electronic access below)
20

Influência do sistema de cimentação adesiva e da fonte de luz fotoativadora na resistência à extrusão de pinos de fibra de vidro /

Lima, Luiz Rafael Calixto. January 2009 (has links)
Resumo: A retenção de pinos pré-fabricados de fibra de vidro, utilizados na restauração de dentes com tratamento endodôntico, é baseada na sua união às superfícies das paredes do canal radicular, por meio dos agentes de fixação resinosos. O tipo de pino utilizado, assim como a fonte de luz fotoativadora do cimento, também pode influenciar nessa retenção, principalmente nas regiões mais críticas do canal, como o terço apical, onde há uma grande dificuldade de acesso dessa luz ativadora. Assim, o propósito deste trabalho foi avaliar comparativamente a influência de diferentes sistemas de cimentação (químico convencional; dual convencional, químico com adesivo auto-condicionante, dual com adesivo auto-condicionante e cimento dual auto-adesivo), na resistência à extrusão (push-out) de pinos de fibra de vidro, nos diferentes terços do canal (cervical, médio, aplical). Foi avaliada também a influência do tipo de fonte de luz fotoativadora do cimento: luz halógena (Optilux 501) e LED (Ultraled). O tipo de falha foi avaliado através de microscopia. Foram utilizadas 240 unidades experimentais, em forma de discos, com aproximadamente 1 mm de espessura, retirados de 80 raízes bovinas, restauradas com retentores intraradiculares. Foi utilizada uma máquina de ensaios universais, MTS 810 Material Test System, à velocidade de 0,5 mm/min-1, com célula de carga de 50 Kg, para avaliação da resistência push-out nos diferentes terços de cada corpo-de-prova. Os valores de resistência em kgf, foram convertidos para MPa e analisados por meio de Análise de Variância e teste de Tukey, com nível de significância de 5%. Os resultados mostraram baixos valores de retenção para os grupos com os cimentos autoadesivos,independente da fonte de luz utilizada. Os cimentos de condicionamento ácido total e os de adesivos auto-condicionantes parecem ser opções viáveis no processo... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The retention of prefabricated glass fiber posts, used for the restoration of endodontically-treated teeth, is based on adhesive systems and resin luting cements. The type of posts used, as well as the type of activation of the cement can also influence this retention, mainly in more critical areas of the radicular dentin, such as the apical root segments, where there is a great difficult access of the light curing units. Thus, the purpose of this study was to evaluate the influence of different resin cements (Chemical-cure total-etch; dual-cure total-etch; chemicalcure and self-etch bonding system, dual-cured and self-etch bonding system; and dual-cure self-adhesive cement) on the bond strength (push-out) of glass fiber posts on the different thirds of the root (cervical, middle and apical). The influence of the light curing unit was evaluated by halogen LCU (Optilux 501) and by LED LCU (LEC II 470) use. The failure mode was evaluated by stereoscopic microscope. Disks of the samples (n=240) were used, with approximately 1 mm of thickness of 80 bovine roots restored with glass fiber posts. A universal testing machine (MTS 810 Material Test System) was used with a 1 mm diameter steel rod at cross-head speed of 0,5 mm/min until post extrusion, with load cell of 50 kg, for evaluation of the push-out strength in different thirds of each sample. The pushout strength values in kgf were converted to MPa and analyzed through Analysis of Variance and Tukey's test, with significant level of 5%. The results of the present study showed that the self-adhesive cements group resulted in low retention values, in every light source utilized. The total-etch cements and the self-etch bonding systems seem to be a viable alternative in the glass fiber posts cementation process, with either halogen light or LEDs. / Orientador: Marcelo Ferrarezi de Andrade / Coorientador: Alessandra Nara de Souza Rastelli / Banca: José Roberto Cury Saad / Banca: Edson Alves de Campos / Mestre

Page generated in 0.0446 seconds