• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 22
  • 1
  • Tagged with
  • 23
  • 11
  • 6
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação da resistência adesiva e características da zircônia após diferentes tratamentos de superfície /

Fernandes Júnior, Virgílio Vilas Boas. January 2017 (has links)
Orientador: Maria Filomena Rocha Lima Huhtala / Banca: Eduardo Bresciani / Banca: João Maurício Ferraz da Silva / Banca: Caio Gorgulho Zanet / Banca: Rogério de Lima Romeiro / Resumo: O objetivo desse estudo in vitro foi avaliar a resistência adesiva, rugosidade superficial, ângulo de contato e o espectro infravermelho da zircônia, após diferentes tratamentos de superfície. Para isso, blocos (n=9) de zircônia Y-TZP (e.max ZirCad - Ivoclar, Schann, Liechtenstein) foram seccionados em 39 fatias (12 x 11x 3 mm) divididas em grupos de acordo com cada teste. Para resistência adesiva, 20 fatias foram divididos em: 2 grupos controle; JAT, jateamento com óxido de alumínio e sílica + primer (Monobond Plus - Ivoclar, Schann, Liechtenstein); HFP, condicionamento com ácido fluorídrico 10% + primer, e 3 experimentais: PL, plasma (Plasma Não Térmico de Superfície - modelo SAP); PLP, plasma + primer; HFPLP, ácido fluorídrico + plasma + primer. Cada fatia de zircônia foi cimentada (Multilink N - Ivoclair, Schann, Liechtenstein) a um bloco pré-polimerizado de resina composta. Após a cimentação os espécimes foram seccionados, e 48 palitos com área adesiva de 1 mm2 foram obtidos em cada grupo para o ensaio de microtração (μTBS). Quatro outras fatias foram submetidas à análise de rugosidade superficial e 12 fatias submetidas à análise do ângulo de contato, após os seguintes tratamentos de superfície: sem tratamento (AV), aplicação de ácido fluorídrico a 10% (AHF), aplicação de plasma (AP) e jateamento (AJ), sendo que para o ângulo de contato foram feitas medições imediatamente após o tratamento, após 12 e 24 horas. Os resultados foram submetidos à análise estatística Anova e ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The purpose of this in vito study was to evaluate zirconia bond strength, surface roughness, contact angle and to mesure infrared spectrum after different surface treatments. Y-TZP zirconium (e.max ZirCAD - Ivoclair, Schann, Liechtenstein) blocks (n=9) were sliced into 36 discs (12 x 11 x 3 mm) and divided (n=4) into surface treatment groups as following: two control groups: JAT, airborneparticle abrasion and HFP, 10% hydrofluoric acid etching + primer (Monobond Plus - Ivoclair, Schann, Liechtenstein)application,and three experimental groups: PL, non-thermal plasma (Surface Non-Thermal Plasma SAP model) application; PLP non-thermal plasma + primer application, and HFPLP, 10% hydrofluoric acid etching + non-thermal plasma + primer application. Each zirconia disk was cemented (Multilink N - Ivoclair, Schann, Liechtenstein) to a pre-polymerized resin block (Filtek Z350 - 3M, St Paul, MN, USA). After cementation the specimens were sectioned and 48 sticks with adhesive area of 1 mm2 obtained from each group for micro-tensile testing (µTBS). Four discs were submitted to surface roughness analysis and 12 discs to contact angle analysis, after the following surface treatments: no treatment (AV), 10% hydrofluoric acid etching (AHF), non-thermal plasma application (AP); and airborne- particle abrasion (AJ). The results were submitted to ANOVA and Tukey's test (p < 0.05). Zirconia surface chemical bonds spectrum was determined in infrared spectroscopy for three specimens after the conditions: no treatment; airborne- particle abrasion and hydrofluoric acid etching + non-thermal plasma application. The results showed no statistically significant differences between the groups JAT and HFPLP, but these two groups were statistically superior to HFP, PL and PLP. Airborne- particle abrasion resulted in a significant increase of surface roughness compared to the other groups...(Resumo completo, clicar acesso eletrônico abaixo) / Doutor
2

Estudo de propriedades físico-químicas de um novo cimento obturador endodôntico

Santos, Alaílson Domingos dos [UNESP] 17 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-17Bitstream added on 2014-06-13T20:42:51Z : No. of bitstreams: 1 santos_ad_dr_bauru.pdf: 5050501 bytes, checksum: 953944123d570eb83506e96c96c8073d (MD5) / Os cimentos odontológicos a base de Cimento Portland, vêm desde a década passada sendo exaustivamente analisados em pesquisas científicas. Comercialmente como exemplo, temos o ProRoot MTA (Tulsa Dental, Oklahoma - USA) e o MTA-Angelus (Angelus Soluções Odontológicas, Londrina - Brazil). Ambos possuem inúmeras qualidades, porém tem inadequado tempo de presa e uma consistência que dificulta o seu manuseio por parte dos clínicos. O Grupo Vidros e Cerâmicas da UNESP - Ilha Solteira desenvolveu um cimento com as mesmas aplicações clínicas do MTA. Estudos recentes mostram que este material (denominado CER), possui propriedades físico-químicas semelhantes àquelas apresentadas pelo MTA. Atualmente tem-se tentado utilizar o cimento MTA como cimento obturador endodôntico, porém, características físicas dificultam seu uso para este fim. A proposta deste trabalho foi mostrar o desenvolvimento de um novo cimento obturador endodôntico, partindo da formulação do CER e testar algumas propriedades físico químicas deste material, tendo como comparação o cimento endodôntico comercial Sealer 26® (Dentsply Ind. E Com. Ltda., Petrópolis-Brazil). Os resultados obtidos mostraram que o cimento CEOE comparado com o Sealer 26®, tem um tempo de presa menor, maior liberação de íons, maior dureza e semelhante adesividade, solubilidade e selabilidade. / In the last decade, the dental cements based on Portland cement have been exhaustively investigated scientifically. Commercially is available the ProRoot MTA (Tulsa Dental, Oklahoma - USA) and MTA-Angelus (Angelus Soluções Dental, Londrina - Brazil) cements. In spite of the excellent physical, chemical and biological properties, one of the main disadvantages with using MTA is its extended setting time and difficult handling. Recently, the Glass and Ceramics group developed an experimental cement with the same clinical applications of MTA. Recent investigations showed that this material (entitled CER) it has physico-chemical properties similar those of the MTA. At present its biological properties are being investigated. One of the principal functions of the MTA is to seal the communications between the root and extern surface of the teeth. Recent studies have been showing that the physical characteristics of the MTA make difficult his use as root-filling cement. The purpose of this study was to developed new endodontic cement based on the formulation of the CER material. The properties evaluate in this study were: setting time, ions release, adhesion, hardness, solubility and sealing ability. The obtained results were compared with the Sealer 26® (Dentsply Ind. e Com. Ltda, Petrópolis-Brazil).
3

Avaliação ex vivo da resistência de união de cimento à base de resina epóxica na dentina humana irradiada com laser Er,Cr:YSGG / Ex vivo bond strength of an epoxy resin-based root canal sealer to human root dentin irradiated with Er,Cr:YSGG laser

Franceschini, Keila de Almeida 26 February 2015 (has links)
O objetivo do presente estudo foi avaliar, ex vivo, a influência da irradiação do laser Er,Cr:YSGG na resistência de união do material obturador à base de resina epóxica à dentina radicular, por meio do teste de push-out, e na interface dentina/material obturador, por meio de microscopia confocal a laser. Avaliou-se, ainda, a variação de temperatura externa da dentina radicular durante irradiação. Para tanto, 96 caninos foram instrumentados com sistema rotatório K3 até #45/.02 e irrigados com 2 mL de água destilada e deionizada entre os instrumentos utilizados. Os espécimes foram distribuídos em 3 grupos (n=32) em função do protocolo de irrigação final (10 mL): água destilada e deionizada, NaOCl 1% e EDTAC 17%. Em seguida, foram redistribuídos em 4 subgrupos (n=8), de acordo com a irradiação do laser: não irradiado, 2 W/20 Hz, 3 W/20 Hz e 4 W/20 Hz. Durante a irradiação, foram aferidos os valores máximo e mínimo de temperatura na parede radicular externa nos terços cervical, médio e apical e no ápice radicular. Após irradiação, os espécimes foram obturados com cimento AH Plus e guta-percha pela técnica de condensação lateral. Decorridos três vezes o tempo de endurecimento o tempo de do cimento, as raízes foram seccionadas transversalmente em slices de 1 mm de espessura. Dois slices de cada terço foram submetidos ao push-out em máquina universal de ensaios e o tipo de falha foi analisado em lupa estereoscópica e classificado em: adesiva ao material obturador, adesiva à dentina, mista, coesiva no material obturador e coesiva na dentina. O slice restante foi submetido à análise em microscopia confocal a laser, onde avaliou-se a porcentagem de perímetro da secção transversal do canal radicular com tags de cimento e a profundidade dos tags na interface dentina/material obturador de forma quali-quantitativa. Os dados de resistência de união (Mpa) e porcentagem de perímetro com tags foram analisados por meio do teste ANOVA; enquanto os dados da variação de temperatura (ºC) e profundidade dos tags (&mu;m) por meio do teste de Kruskal-Wallis, ambos seguidos de teste de Tukey. A irradiação do laser Er,Cr:YSGG aumentou a resistência de união do cimento obturador à dentina, independente da irrigação final, sendo que os maiores valores foram obtidos para as potência de 3 W (4,02±1,32) e 4 W (4,18±0,98) e os menores valores para o grupo não irradiado (2,64±0,58) (p<0,05). A potência de 2 W (3,28±0,91) apresentou valores intermediários. A irrigação final com EDTAC 17% resultou em maiores valores de resistência de união (4,01±1,02) quando comparado à água destilada (3,11±1,09) e ao NaOCl 1% (3,47±1,18) (p<0,05). Em relação aos terços radiculares, o terço cervical (4,01±1,21) apresentou valor de resistência de união estatisticamente maior que o terço apical (3,04±0,89), enquanto o terço médio apresentou valores intermediários (3,54±1,15) (p<0,05). Em todos os grupos foi observado maior percentual de falhas adesivas e mistas. Nos grupos irradiados com 3 W [21,1 (14,1-27,7)] e 4 W [17,8 (11,9-23,7)] foi observado maior profundidade de tags do material obturador quando comparado ao grupo não irradiado [12,9 (9,0-20,0)]; a potência de 2 W promoveu valores intermediários [15,6 (11,7-23,3)] de profundidade de tags. Os maiores percentuais de perímetro com tags foram observados para os grupos irradiados, não havendo diferença estatística entre eles (p>0,05). O aumento da temperatura foi proporcional ao aumento da potência do laser, não excedendo 3 ºC. Concluiu-se que o laser Er,Cr:YSGG promoveu aumento da resistência de união do cimento à base de resina epóxica à dentina radicular, com maior formação de tags em todas as potências estudadas, principalmente quando associado à irrigação final com EDTAC 17%; o aumento da temperatura durante a irradiação não foi considerado elevado a ponto de prejudicar os tecidos adjacentes. / The aim of this study was to evaluate ex vivo the influence of Er,Cr:YSGG laser irradiation on the bond strength of an epoxy resin-based root canal sealer to root dentin, using the push-out test, and on the dentin/filling material interface, using confocal laser microscopy. The temperature variation on the outer root dentin during irradiation was also evaluated. For this purposes, 96 canines were instrumented with K3 rotary system up to the #45/.02 instrument, irrigating with 2 mL of distilled and deionized water at each change of instrument. The specimens were randomly assigned to 3 groups (n=32), according the final irrigation protocol (10 mL): distilled and deionized water, 1% NaOCl and 17% EDTAC. They were next reassigned into 4 subgroups (n=8), according to the laser irradiation parameters: non-irradiated, 2 W/20 Hz, 3 W/20 Hz and 4 W/20 Hz. During irradiation, the maximum and minimum temperatures were measured on the outer root dentin wall in the cervical, middle and apical thirds as well in the root apex. Following irradiation, the canals were filled with lateral condensation of AH Plus sealer and gutta-percha cones. After a period three times longer than the sealers setting time, the roots were sectioned transversally to obtain 1-mm-thick slices. Two slices from each third were subjected to a push-out test in a universal testing machine and the failure mode was analyzed with stereoscopic lens and classified as: adhesive to the filling material, adhesive to dentin, mixed, cohesive in the filling material and cohesive in dentin. The remaining slice was analyzed by confocal laser microscopy to evaluate the percentage of the perimeter of the root canal cross-section with sealer tags. The depth of tags at the dentin/filling material interface was evaluated in a quali-quantitative manner. Bond strength (MPa) data and the percentage of perimeter with tags were analyzed by ANOVA, while temperature variation (ºC) and tag depth (&mu;m) were analyzed by Kruskal-Wallis test, both followed by Tukeys test. The Er,Cr:YSGG laser irradiation increased sealer bond strength to dentin, regardless of the final irrigation protocol. The highest values were obtained for 3 W (4.02±1.32) and 4 W (4.18±0.98) powers and the lowest for the non-irradiated group (2.64±0.58) (p<0.05). The use of 2 W power (3.28±0.91) resulted in intermediate values. Final irrigation with 17% EDTAC provided higher bond strength (4.01±1.02) compared with distilled water (3.11±1.09) and 1% (NaOCl 3.47±1.18) (p<0.05). Regarding the root thirds, the cervical third (4.01±1.21) presented significantly higher bond strength than the apical third (3.04±0.89), while the middle third presented intermediate values (3.54±1.15) (p<0.05). In all groups, there was a greater percentage of adhesive and mixed failures. In the groups irradiated with 3 W [21.1 (14.1-27.7)] and 4 W [17.8 (11.9-23.7)], it was observed a greater depth of filling material tags compared with the non-irradiated group [12.9 (9.0-20.0)]; 2 W power produced intermediate tag depth values [15.6 (11.7-23.3)]. The greatest percentage of canal perimeter with sealer tags was observed in the irradiated groups, with no statistically significant difference among them (p>0.05). The temperature rise was proportional to the increase of laser power, not surpassing 3 °C. It was therefore concluded that Er,Cr:YSGG laser irradiation increased the bond strength of an epoxy resin-based sealer to root dentin, with greater formation of sealer tags when for all tested powers, especially if combined with final irrigation with 17% EDTAC; temperature rise during irradiation was not considered high enough to cause harmful effects to the adjacent tissues.
4

Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário

Araújo, Taylane Soffener Berlanga de [UNESP] 15 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-15Bitstream added on 2014-06-13T19:01:40Z : No. of bitstreams: 1 araujo_tsb_dr_arafo.pdf: 876638 bytes, checksum: 4edaacd253f53829f5fdb7d87cab5c0b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um Software-Image Tool, no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region.
5

Avaliação ex vivo da resistência de união de cimento à base de resina epóxica na dentina humana irradiada com laser Er,Cr:YSGG / Ex vivo bond strength of an epoxy resin-based root canal sealer to human root dentin irradiated with Er,Cr:YSGG laser

Keila de Almeida Franceschini 26 February 2015 (has links)
O objetivo do presente estudo foi avaliar, ex vivo, a influência da irradiação do laser Er,Cr:YSGG na resistência de união do material obturador à base de resina epóxica à dentina radicular, por meio do teste de push-out, e na interface dentina/material obturador, por meio de microscopia confocal a laser. Avaliou-se, ainda, a variação de temperatura externa da dentina radicular durante irradiação. Para tanto, 96 caninos foram instrumentados com sistema rotatório K3 até #45/.02 e irrigados com 2 mL de água destilada e deionizada entre os instrumentos utilizados. Os espécimes foram distribuídos em 3 grupos (n=32) em função do protocolo de irrigação final (10 mL): água destilada e deionizada, NaOCl 1% e EDTAC 17%. Em seguida, foram redistribuídos em 4 subgrupos (n=8), de acordo com a irradiação do laser: não irradiado, 2 W/20 Hz, 3 W/20 Hz e 4 W/20 Hz. Durante a irradiação, foram aferidos os valores máximo e mínimo de temperatura na parede radicular externa nos terços cervical, médio e apical e no ápice radicular. Após irradiação, os espécimes foram obturados com cimento AH Plus e guta-percha pela técnica de condensação lateral. Decorridos três vezes o tempo de endurecimento o tempo de do cimento, as raízes foram seccionadas transversalmente em slices de 1 mm de espessura. Dois slices de cada terço foram submetidos ao push-out em máquina universal de ensaios e o tipo de falha foi analisado em lupa estereoscópica e classificado em: adesiva ao material obturador, adesiva à dentina, mista, coesiva no material obturador e coesiva na dentina. O slice restante foi submetido à análise em microscopia confocal a laser, onde avaliou-se a porcentagem de perímetro da secção transversal do canal radicular com tags de cimento e a profundidade dos tags na interface dentina/material obturador de forma quali-quantitativa. Os dados de resistência de união (Mpa) e porcentagem de perímetro com tags foram analisados por meio do teste ANOVA; enquanto os dados da variação de temperatura (ºC) e profundidade dos tags (&mu;m) por meio do teste de Kruskal-Wallis, ambos seguidos de teste de Tukey. A irradiação do laser Er,Cr:YSGG aumentou a resistência de união do cimento obturador à dentina, independente da irrigação final, sendo que os maiores valores foram obtidos para as potência de 3 W (4,02±1,32) e 4 W (4,18±0,98) e os menores valores para o grupo não irradiado (2,64±0,58) (p<0,05). A potência de 2 W (3,28±0,91) apresentou valores intermediários. A irrigação final com EDTAC 17% resultou em maiores valores de resistência de união (4,01±1,02) quando comparado à água destilada (3,11±1,09) e ao NaOCl 1% (3,47±1,18) (p<0,05). Em relação aos terços radiculares, o terço cervical (4,01±1,21) apresentou valor de resistência de união estatisticamente maior que o terço apical (3,04±0,89), enquanto o terço médio apresentou valores intermediários (3,54±1,15) (p<0,05). Em todos os grupos foi observado maior percentual de falhas adesivas e mistas. Nos grupos irradiados com 3 W [21,1 (14,1-27,7)] e 4 W [17,8 (11,9-23,7)] foi observado maior profundidade de tags do material obturador quando comparado ao grupo não irradiado [12,9 (9,0-20,0)]; a potência de 2 W promoveu valores intermediários [15,6 (11,7-23,3)] de profundidade de tags. Os maiores percentuais de perímetro com tags foram observados para os grupos irradiados, não havendo diferença estatística entre eles (p>0,05). O aumento da temperatura foi proporcional ao aumento da potência do laser, não excedendo 3 ºC. Concluiu-se que o laser Er,Cr:YSGG promoveu aumento da resistência de união do cimento à base de resina epóxica à dentina radicular, com maior formação de tags em todas as potências estudadas, principalmente quando associado à irrigação final com EDTAC 17%; o aumento da temperatura durante a irradiação não foi considerado elevado a ponto de prejudicar os tecidos adjacentes. / The aim of this study was to evaluate ex vivo the influence of Er,Cr:YSGG laser irradiation on the bond strength of an epoxy resin-based root canal sealer to root dentin, using the push-out test, and on the dentin/filling material interface, using confocal laser microscopy. The temperature variation on the outer root dentin during irradiation was also evaluated. For this purposes, 96 canines were instrumented with K3 rotary system up to the #45/.02 instrument, irrigating with 2 mL of distilled and deionized water at each change of instrument. The specimens were randomly assigned to 3 groups (n=32), according the final irrigation protocol (10 mL): distilled and deionized water, 1% NaOCl and 17% EDTAC. They were next reassigned into 4 subgroups (n=8), according to the laser irradiation parameters: non-irradiated, 2 W/20 Hz, 3 W/20 Hz and 4 W/20 Hz. During irradiation, the maximum and minimum temperatures were measured on the outer root dentin wall in the cervical, middle and apical thirds as well in the root apex. Following irradiation, the canals were filled with lateral condensation of AH Plus sealer and gutta-percha cones. After a period three times longer than the sealers setting time, the roots were sectioned transversally to obtain 1-mm-thick slices. Two slices from each third were subjected to a push-out test in a universal testing machine and the failure mode was analyzed with stereoscopic lens and classified as: adhesive to the filling material, adhesive to dentin, mixed, cohesive in the filling material and cohesive in dentin. The remaining slice was analyzed by confocal laser microscopy to evaluate the percentage of the perimeter of the root canal cross-section with sealer tags. The depth of tags at the dentin/filling material interface was evaluated in a quali-quantitative manner. Bond strength (MPa) data and the percentage of perimeter with tags were analyzed by ANOVA, while temperature variation (ºC) and tag depth (&mu;m) were analyzed by Kruskal-Wallis test, both followed by Tukeys test. The Er,Cr:YSGG laser irradiation increased sealer bond strength to dentin, regardless of the final irrigation protocol. The highest values were obtained for 3 W (4.02±1.32) and 4 W (4.18±0.98) powers and the lowest for the non-irradiated group (2.64±0.58) (p<0.05). The use of 2 W power (3.28±0.91) resulted in intermediate values. Final irrigation with 17% EDTAC provided higher bond strength (4.01±1.02) compared with distilled water (3.11±1.09) and 1% (NaOCl 3.47±1.18) (p<0.05). Regarding the root thirds, the cervical third (4.01±1.21) presented significantly higher bond strength than the apical third (3.04±0.89), while the middle third presented intermediate values (3.54±1.15) (p<0.05). In all groups, there was a greater percentage of adhesive and mixed failures. In the groups irradiated with 3 W [21.1 (14.1-27.7)] and 4 W [17.8 (11.9-23.7)], it was observed a greater depth of filling material tags compared with the non-irradiated group [12.9 (9.0-20.0)]; 2 W power produced intermediate tag depth values [15.6 (11.7-23.3)]. The greatest percentage of canal perimeter with sealer tags was observed in the irradiated groups, with no statistically significant difference among them (p>0.05). The temperature rise was proportional to the increase of laser power, not surpassing 3 °C. It was therefore concluded that Er,Cr:YSGG laser irradiation increased the bond strength of an epoxy resin-based sealer to root dentin, with greater formation of sealer tags when for all tested powers, especially if combined with final irrigation with 17% EDTAC; temperature rise during irradiation was not considered high enough to cause harmful effects to the adjacent tissues.
6

Avaliação da resistência adesiva e características da zircônia após diferentes tratamentos de superfície / Bond strength and surface characteristics evaluation of zirconia after different treatments

Fernandes Júnior, Virgílio Vilas Boas [UNESP] 01 September 2017 (has links)
Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T17:19:32Z No. of bitstreams: 1 Tese FInal .pdf: 39214788 bytes, checksum: 9123d03a17e8efd22b18caf0276a31db (MD5) / Rejected by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br), reason: Solicitado pelo autor. on 2017-10-25T18:25:54Z (GMT) / Submitted by Virgílio Vilas Bôas Fernandes Júnior (virgiliovilas@hotmail.com) on 2017-10-25T19:32:12Z No. of bitstreams: 1 Tese Final pdf 3.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-10-30T17:58:25Z (GMT) No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) / Made available in DSpace on 2017-10-30T17:58:25Z (GMT). No. of bitstreams: 1 fernandesjunior_vvb_dr_sjc.pdf: 39239343 bytes, checksum: a57241186129e7ab3539248847265232 (MD5) Previous issue date: 2017-09-01 / O objetivo desse estudo in vitro foi avaliar a resistência adesiva, rugosidade superficial, ângulo de contato e o espectro infravermelho da zircônia, após diferentes tratamentos de superfície. Para isso, blocos (n=9) de zircônia Y-TZP (e.max ZirCad - Ivoclar, Schann, Liechtenstein) foram seccionados em 39 fatias (12 x 11x 3 mm) divididas em grupos de acordo com cada teste. Para resistência adesiva, 20 fatias foram divididos em: 2 grupos controle; JAT, jateamento com óxido de alumínio e sílica + primer (Monobond Plus - Ivoclar, Schann, Liechtenstein); HFP, condicionamento com ácido fluorídrico 10% + primer, e 3 experimentais: PL, plasma (Plasma Não Térmico de Superfície - modelo SAP); PLP, plasma + primer; HFPLP, ácido fluorídrico + plasma + primer. Cada fatia de zircônia foi cimentada (Multilink N - Ivoclair, Schann, Liechtenstein) a um bloco pré-polimerizado de resina composta. Após a cimentação os espécimes foram seccionados, e 48 palitos com área adesiva de 1 mm2 foram obtidos em cada grupo para o ensaio de microtração (μTBS). Quatro outras fatias foram submetidas à análise de rugosidade superficial e 12 fatias submetidas à análise do ângulo de contato, após os seguintes tratamentos de superfície: sem tratamento (AV), aplicação de ácido fluorídrico a 10% (AHF), aplicação de plasma (AP) e jateamento (AJ), sendo que para o ângulo de contato foram feitas medições imediatamente após o tratamento, após 12 e 24 horas. Os resultados foram submetidos à análise estatística Anova e teste de Tukey a 5% (p< 0,05). Os espectros das ligações químicas da superfície da zircônia foram determinados em 3 outras amostras após as seguintes condições: sem tratamento (AV), jateamento (JAT) e aplicação de ácido fluorídrico 10% seguido da aplicação do plasma (AHFP). Em termos de adesão, não houve diferença estatística significante entre os grupos JAT e HFPLP, porém esses 2 foram estatisticamente superiores ao grupos HFP, PL e PLP. O jateamento demonstrou aumentar significantemente a rugosidade superficial em relação aos demais grupos. O plasma demonstrou diminuir o ângulo de contato da superfície da zircônia imediatamente e ao longo de 48 horas. / The purpose of this in vito study was to evaluate zirconia bond strength, surface roughness, contact angle and to mesure infrared spectrum after different surface treatments. Y-TZP zirconium (e.max ZirCAD - Ivoclair, Schann, Liechtenstein) blocks (n=9) were sliced into 36 discs (12 x 11 x 3 mm) and divided (n=4) into surface treatment groups as following: two control groups: JAT, airborneparticle abrasion and HFP, 10% hydrofluoric acid etching + primer (Monobond Plus - Ivoclair, Schann, Liechtenstein)application ,and three experimental groups: PL, non-thermal plasma (Surface Non-Thermal Plasma SAP model) application; PLP non-thermal plasma + primer application, and HFPLP, 10% hydrofluoric acid etching + non-thermal plasma + primer application. Each zirconia disk was cemented (Multilink N - Ivoclair, Schann, Liechtenstein) to a pre-polymerized resin block (Filtek Z350 - 3M, St Paul, MN, USA). After cementation the specimens were sectioned and 48 sticks with adhesive area of 1 mm2 obtained from each group for micro-tensile testing (μTBS). Four discs were submitted to surface roughness analysis and 12 discs to contact angle analysis, after the following surface treatments: no treatment (AV), 10% hydrofluoric acid etching (AHF), non-thermal plasma application (AP); and airborne- particle abrasion (AJ). The results were submitted to ANOVA and Tukey's test (p < 0.05). Zirconia surface chemical bonds spectrum was determined in infrared spectroscopy for three specimens after the conditions: no treatment; airborne- particle abrasion and hydrofluoric acid etching + non-thermal plasma application. The results showed no statistically significant differences between the groups JAT and HFPLP, but these two groups were statistically superior to HFP, PL and PLP. Airborne- particle abrasion resulted in a significant increase of surface roughness compared to the other groups. Non-thermal plasma was shown to decrease the contact angle of the surface, within 48 hours.
7

Resistência de união, por push-out, de pinos de fibra fixados à dentina bovina com diferentes agentes cimentantes / Bond strength, by push-out the pins of fibers is fixed bovine dentin with different luting agents

Rodrigo Asfury Rodrigues 24 September 2010 (has links)
O grau de adesividade do cimento resinoso dual é, quase sempre, superior ao oferecido pelo sistema de adesão química e pelo cimento ionomérico. Objetivo: foi proposta deste estudo avaliar a resistência de união, por push-out, de pinos de fibra de vidro cimentados a dentina bovina com diferentes agentes cimentantes. Método: foram selecionados trinta dentes bovinos e suas coroas removidas imediatamente abaixo da junção cemento-esmalte. As polpas dentais foram retiradas com lima tipo k n 80 e os condutos irrigados com soro fisiológico 0,9% e secos com cones de papel absorvente. Em seguida, com auxílio da broca que acompanha o pino de fibra de vidro, foram preparados com comprimento de trabalho de 11mm, novamente irrigados com soro fisiológico 0,9% e secos com cones de papel absorvente. As raízes dos dentes bovinos foram divididas em três grupos de acordo com o material utilizado para a cimentação: grupo I (n=10) - ionômero de vidro (fuji), grupo II (n=10) - cimento resinoso dual relyx (3m espe) e grupo III (n=10) - cimento resinoso quimicamente ativado multilink (ivoclar/vivadent). Anteriormente a cimentação, realizada seguindo as recomendações dos fabricantes, todos os pinos foram limpos com ácido fluorídrico a 10% por 30s e os pinos dos grupos II e III silanizados. As raízes dentárias foram seccionadas transversalmente em três terços: cervical, médio e apical e cada segmento obtido foi submetido ao teste push-out em máquina de ensaio universal (versat 2000). Após o ensaio de push-out, o tipo de falha ocorrido nos espécimes foi analisado em estereomicroscópio. Resultados: os dados obtidos foram submetidos à análise estatística utilizando os testes anova one-way e Tuckey (p<0,05), com auxílio do programa biostat 15.0. Na análise intra-grupo, diferença significativa foi evidenciada entre os terços cervical e apical e médio e apical para todos os cimentos utilizados e entre os terços cervical e médio quando utilizado o cimento Relyx. Com relação à análise inter-grupos, diferença significativa foi observada na região cervical entre os grupos III e I, III e II, I e II. Nos terços médio e apical, diferença significativa foi observada entre os grupos III e II, I e II. Conclusões: foi observada diferença significativa entre o grau de adesividade apresentado pelos diferentes agentes cimentantes utilizados e entre os diferentes seguimentos radiculares. Os maiores valores de resistência adesiva foram apresentados pelo cimento resinoso Relyx, seguido do cimento de ionômero de vidro Fuji e cimento resinoso quimicamente ativado Mmultilink, respectivamente. Valores de resistência de união superiores foram verificados no terço cervical independentemente do grupo avaliado (p<0,05). / The degree of adhesion of dual resin cement is higher than those offered by the system of chemical bonding or glass ionomer cement. Objective: was proposed in this study to evaluate the bond strength, for push-out pins of the interface of glass fiber / bovine dentin with different luting agents. Method: The conduits thirty bovine teeth were accessed with file type K # 80, irrigated with saline 0.9% and dried with absorbent paper cones. Were then prepared with the aid of the drill that comes with the pin of fiberglass, with the working length of 11mm, irrigated with 0.9% and again dried with absorbent paper cones. Then, the bovine teeth were divided into three groups according to the material used for cementation: Group I - glass ionomer (Fuji), group II - dual resin cement RelyX (3M Espe) and group III - chemically activated resin cement Multilink (Ivoclar / Vivadent). In all groups, the pins were cleaned with 10% hydrofluoric acid for 30s and cemented following the operating instructions supplied by the cement manufacturers. Before cementation groups II and III were silanized. Subsequently, the tooth roots were sectioned into three thirds: the cervical, middle and apical and each segment was obtained before the push-out test in a universal testing machine (EMIC DL 2000). Results: The results were tabulated and analyzed statistically using one-way ANOVA and Tukey (p <0.05). Statistical analysis was performed in Biostat 15.0. With differences in intra-group and inter-groups. Conclusions: we concluded that there was no difference in the degree of adhesiveness Significativo with different groups of cements and in different root segments, with significant strength values for cement RelyX, followed by glass ionomer cement Fuji and chemically activated Multilink, respectively. With values of bond strength statistically significant at the cervical regardless of the group assessed.
8

Viabilidade do uso de soluções de extratos naturais no tratamento restaurador da dentina / Viability of using natural extracts solutions in dentin restorative treatment

Ziotti, Isabella Rodrigues 29 January 2016 (has links)
Este estudo teve por objetivo avaliar, in vitro, a viabilidade do uso de soluções de extratos naturais no tratamento restaurador da dentina, por meio do ensaio de resistência à microtração e análise qualitativa da superfície dentinária e interface adesiva em microscopia eletrônica de varredura (MEV). A amostra foi composta de 90 fragmentos de dentina bovina. Os fragmentos foram planificados, polidos e condicionados com ácido fosfórico 37% e, em seguida, divididos de acordo com o tratamento da dentina em 5 níveis: GI Sem tratamento (controle), GII Solução de extrato de Camellia sinensis (chá verde), GIII Solução de extrato de Punica granatum (romã), GIV Solução de extrato de Vitis vinifera (semente de uva), GV Solução de extrato de Lycium barbarum (goji berry). Os espécimes que foram utilizados na análise da resistência de união e interface adesiva tiveram as superfícies restauradas com adesivo (Adper Single Bond 2 - 3M) e resina composta (Filtek Z250 - 3M). Os 60 fragmentos utilizados para o teste de microtração (6 mm x 6 mm x 6 mm) foram seccionados em palitos de aproximadamente 1 mm&sup2, obtendo-se 4 palitos por dente (n=12). Após o teste, o padrão de falhas foi analisado em microscopia de varredura confocal a laser (MVCL). Para análise da interface adesiva, 15 fragmentos (6 mm x 3 mm x 3 mm) foram tratados com as soluções (n=3), restaurados e preparados para MEV. Os 15 fragmentos (3 mm x 3 mm x 3 mm) destinados à análise da superfície foram tratados com as soluções (n=3) e preparados para MEV. Os dados do teste de microtração (MPa) foram submetidos à ANOVA e teste de Tukey (p=0,05). Os maiores valores médios de resistência adesiva (p < 0,05) foram obtidos nos grupos controle (sem tratamento, GI - 25,69 ± 6,32), extrato de Camellia sinenis (chá verde, GII - 28,14 ± 7,66) e extrato de Vitis vinifera (semente de uva, GIV - 25,55 ± 4,00), sendo estes iguais entre si (p > 0,05). Os fragmentos tratados com o extrato de Punica granatum apresentaram os menores valores médios (p < 0,05) de resistência adesiva (Romã, GIII - 17,42 ± 4,82). Os fragmentos que receberam o extrato de Lycium barbarum apresentaram valores intermediários (Goji Berry, GV - 23,44 ± 6,78), ora similares aos dos grupos com maiores médias, ora iguais ao grupo de menor média de resistência adesiva (p > 0,05). Falhas adesivas foram predominantes nos grupos experimentais. Na análise em MEV da superfície dentinária, verificou-se superfície regular, sem camada de smear e com abertura dos túbulos dentinários em todos os grupos analisados. Na análise da interface adesiva, houve boa hibridização da embocadura dos canais, e presença de tags resinosos na maioria dos túbulos dentinários, sugerindo formação de camada hibrida. As soluções de Camellia sinensis, Vitis vinifera e Lycium barbarum não interferiram negativamente na resistência de união quando comparados ao grupo controle, sem tratamento. / This study aimed to evaluate, in vitro, the viability of using natural extracts solutions in dentin restorative treatment, by microtensile bond strength test and qualitative analysis of dentin morphology surface and adhesive interface under scanning electron microscopy (SEM). Sample was composed of 90 fragments of intracoronary bovine dentin. The fragments were flattened, etched with 37% phosphoric acid and then were divided according to the dentin treatments: GI - Untreated (control), GII - Camellia sinensis extract solution (green tea), GIII - Punica granatum extract solution (pomegranate), GIV - Vitis vinifera extract solution (grape seed), GV - Lycium barbarum extract solution (goji berry). Specimens that were used on the bond strength test and adhesive interface analysis were restored with adhesive (Single Bond 2 - 3M) and composite resin (Filtek Z250 - 3M). The 60 fragments used to microtensile test (MPa) (6mm x 6mm x 6mm) were sectioned at approximately 1mm2 sticks, 4 destined to the bonding interface analysis (n=12). After the test, the failure pattern was analyzed in confocal laser scanning microscopy (CLSM). For adhesive interface analysis, 15 pieces (6mm x 3mm x 3mm) were treated with solutions, restored and prepared for SEM (n=3). The 15 fragments (3mm x 3mm x 3mm) destined for surface analysis were treated with solutions and prepared for SEM (n=3). The microtensile test (MPa) data were submitted to ANOVA and Tukey test (p=0.05). The highest values of bond strength (p<0.05) were obtained in the control groups (untreated, GI - 25.69 ± 6.32), Camellia sinenis extract (green tea, GII - 28.14 ± 7. 66) and Vitis vinifera extract (grape seed, GIV - 25.55 ± 4.00), which are equal to each other (p>0.05). The fragments treated with Punica granatum extract (Pomegranate, GIII - 17.42 ± 4.82) showed lowest values of bond strength (p <0.05). Fragments treated with Lycium barbarum extract showed intermediate values (Goji Berry, GV - 23.44 ± 6.78), similar to those of groups with higher values and to the lower values group of bond strength (p>0.05). Adhesive failures were predominant in all groups. The SEM analysis of the dentin surface demonstrated that there was a regular surface, without smear layer and open dentinal tubules in all groups analyzed. The adhesive interface analysis, showed that there was good hybridization of the entrance of dentinal tubules, and presence of resin tags in most dentinal tubules, suggesting formation of hybrid layer. The extracts solutions of Camellia sinensis, Vitis vinifera and Lycium barbarum did not interfere negatively on the bond strength when compared to the control group without treatment.
9

Efeito de inibidores da atividade proteolítica na resistência de união de pino de fibra de vidro à dentina radicular após 12 meses / Effect of proteolytic activity inhibitors on bond strength of glass-fiber post to radicular dentin up to 12 months

Chaves, Larissa Pinceli 19 August 2016 (has links)
O estabelecimento de uma camada híbrida adequada no canal radicular representa um dos principais desafios clínicos devido à dificuldade de acesso. Dessa forma, o uso de inibidores proteolíticos poderia tornar-se um recurso favorável. O objetivo deste estudo foi avaliar o efeito de inibidores proteolíticos na união de pino de fibra de vidro fixado com cimento adesivo, considerando os terços radiculares e tempos distintos, por meio da resistência de união (RU). Cento e quarenta e quatro raízes bovinas foram selecionadas e divididas em 6 grupos de tratamento, e redivididas em 3 subgrupos de acordo com os tempos de avaliação de 24 horas, 6 e 12 meses (n=8). Após o tratamento endodôntico e desobturação padronizados, as raízes foram cimentadas com pinos de fibra de vidro cônicos (Exacto/Angelus). As raízes foram tratadas com sistema adesivo convencional de três passos, Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) e cimento dual RelyX ARC/ 3M ESPE. Após prévia divisão, foram alocadas em grupos CN (Controle Negativo- sem pré tratamento associado), CP (Controle Positivo- com agentes ativador e catalisador), EDTA (ácido etilenodiamino tetra-acético a 17%), CHX (digluconato de clorexidina a 2%), E-5 (E- 64 a 5 M) e E-10 (E-64 a 10 M). Após 24 horas, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias de 1 mm de espessura (cervical, médio e apical), que foram armazenadas em saliva artificial para serem testadas. Todas as fatias foram submetidas ao teste de extrusão (push-out) na máquina de teste universal (Instron) com célula de carga de 50 N a 0,5 mm/min. Os dados foram analisados pelo teste de ANOVA a três critérios e comparações múltiplas com Tukey, ambos com p<0,05. Após 24 horas, não se observou diferenças entre os tratamentos. Após 6 meses, a CHX demonstrou melhor desempenho, cujo efeito não se prorrogou até os 12 meses. O uso de inibidores proteolíticos não foram capazes de preservar a resistência de união dos pinos intrarradiculares até o tempo de 12 meses. / The adequate establishment of hybrid layer in the root canal on bonding process is still a clinical challenge due to its hard access. Thus, the use of proteolytic inhibitors could become a favorable tool. The aim of this study was to evaluate the effect of proteolytic inhibitors in the bonding of a glass- fiber post fixed with a luting cement, regarding the root thirds and different times through the bond strength. One hundred and forty four bovine roots were selected and divided into 6 treatment groups, and subdivided according to the time of evaluation of 24 hours, 6 and 12 months (n=8). After endodontic treatment and standardized removal procedure, the roots were cemented with tapered glass fiber posts (Exacto/ Angelus). The roots were treated with three-step etch-and-rinse adhesive system Adper Scotchbond Multipurpose/ 3M ESPE (SBMP) and dual cement RelyX ARC/ 3M ESPE. After previous division, CN (negative- control without pre associated treatment), CP (Control positive- with activator and catalyst agents) EDTA (17% ethylenediaminetetraacetic acid) CHX (2% chlorhexidine digluconate) E-5 (5M E-64) and E-10 (10M E-64). After 24h, the roots were sectioned perpendicular to the long axis and identified according to third in 1mm thick slices (cervical, middle and apical), which were stored in artificial saliva to be tested. All slices were subjected to extrusion tests (push-out) in the universal test machine (Instron) at 50 N load cell at 0.5 mm/min. Data were analyzed with three-way ANOVA and multiple comparisons with Tukey test, both with p <0.05. After 24 hours, no differences were observed between treatments. After 6 months, CHX showed better performance, which did not last up 12 months. The proteolytic inhibitors performed differently in the bonding process over time; only CHX promoted inhibition at 6 months. The use of proteolytic inhibitors were not able to maintain the bond strength of intraradicular posts up time of 12 months.
10

ANÁLISE DE SEQUÊNCIA ALTERNATIVA PARA RESTAURAÇÃO LAMINADA:CIMENTO DE IONÔMERO DE VIDRO E RESINA COMPOSTA / Alternative sequence analysis for sandwich technique: glass ionomer cement and composite resin

Queiroz, Vania Aparecida Oliveira 06 December 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:28Z (GMT). No. of bitstreams: 1 Vania Aparecida Oliveira Queiroz.pdf: 2334313 bytes, checksum: edfd28d0622cb45ff6c0fde23b982588 (MD5) Previous issue date: 2012-12-06 / Evaluate an alternative sequence for the sandwich technique using the microtensile bond strength testing on glass-ionomer cement (GIC)-dentin and GICcomposite resin (CR) interfaces (in 7 days), and to analyze the mechanical properties (hardness and modulus of elasticity) of GIC-RC interface (in 7 days and 24 months), by the use of nano-indentation. Methods: For that, class I cavities were cut into 60 extracted human molars. The cavities were filled using two diferent sequences of closed sandwich technique with conventional glass-ionomer cement (CGIC) (KetacTM Fil Plus/3M), and resin-modified glass-ionomer cement (RMGIC) (VitrebondTM/3M).The sequences were called, convencional sequence (CS) (etching GICs surface) and alternative sequence (AS) (without etching GICs surface), and they were used in all groups RMGIC-CR, RMGIC-dentin, CGIC-CR, and CGIC-dentin. After storage period, the teeth were horizontally sectioned, along vestibular wall of the class I cavities, for the bond strength of GICs-dentin tests. For analysis of the mechanical properties and bond strength of GICs-CR, the teeth were longitudinally sectioned.The specimens intended for mechanical properties testing have been removed from the sandwich restorations center areas. For the adhesion tests, the beams were aligned, and attached to a jig employing the active gripping method and stressed in tension (MPa). For the mechanical test, the specimens were embedded, and polished, and submitted to nano-indentation (GPa). The data were analyzed by Kruskal-Wallis, Dunn, and Chi-square tests (p<0.05). Results: The GICRM presented better adhesion to dentin and CR, and the CGIC presented better mechanical properties. When was used the RMGIC, both sequences did not present differences in adhesion (dentin and CR), and in mechanical properties (RMGIC,interface, and CR) in 7 days and 24 months. Concerning CGIC-dentin and CGIC-CR,also did not find a significant difference between both sequences, despite the adhesion means difference CGIC-CR between the CS (0.96 MPa) and AS (5.78 MPa). The CS presented a significant number of spontaneously debonded beams at interface with the CR before testing (77.33%) than AS (16%). The mechanical properties analysis of CGIC-interface-CR, in 7 days and 24 months, showed significant differences between techniques. At seven days, no GICC-RC interface data was obtained due to deteriorating condition, while AS showed 0.42 GPa (hardness) and 7.50 GPa (modulus of elasticity) values. After 24 months, AS showed hardness and modulus of elasticity, respectively, 1.24 e 20.96 GPa (CGIC), and 0.40 e 7.05 GPa (interface), while CS showed 0.51 e 8.14 GPa (CGIC) without any interface value. Conclusion: The AS has performed a good option for laminate or sandwich technique when RMGIC was used, and it was the best option when a CGIC was used. / Avaliar uma sequência alternativa para a técnica do sanduíche pela análise da resistência adesiva por microtração nas interfaces cimento de ionômero de vidro (CIV)-dentina e CIV-resina composta (RC) (aos 7 dias) e pela análise das propriedades mecânicas (dureza e módulo de elasticidade) por nanoendentação na interface CIV-RC (aos 7 dias e 24 meses). Material e métodos: Para isto, foram preparadas cavidades de classe I em 60 molares humanos extraídos. As cavidades foram restauradas utilizando duas sequências técnicas diferentes para o sanduíche fechado: com cimento de ionômero de vidro convencional (CIVC) (KetacTM Fil Plus/3M) e com cimento de ionômero de vidro modificado por resina (CIVMR) (VitrebondTM/3M). As técnicas foram denominadas, sequência convencional (SC) (com condicionamento superficial do CIV) e sequência alternativa (SA) (sem condicionamento superficial do CIV), e empregadas em todos os grupos de CIVMRRC, CIVMR-dentina, CIVC-RC e CIVC-dentina. Após períodos de armazenamento, os dentes foram seccionados horizontalmente, ao longo da parede vestibular do preparo de classe I, para o teste de resistência adesiva CIV-dentina. Para análise das propriedades mecânicas e para o teste de resistência adesiva CIV-RC, os dentes foram seccionados longitudinalmente. Os espécimes destinados às análises das propriedades mecânicas foram retirados do centro das restaurações de sanduíche. Para o teste de resistência adesiva, os palitos foram alinhados e colados ao dispositivo da máquina de tração pelo método de fixação ativo e estressados em tensão (MPa). Para análise das propriedades mecânicas, os espécimes foram fixados com parafina no suporte de teste, polidos e submetidos a nanoendentação (GPa). Os testes Kruskal-Wallis, Dunn e Qui-Quadrado foram utilizados para análise dos dados (p<0,05). Resultados: O CIVMR demonstrou maior adesão, à dentina e à RC, e o CIVC demonstrou melhores propriedades mecânicas. Quando foi utilizado o CIVMR, as duas sequências técnicas estudadas não apresentaram diferenças na resistência adesiva (à dentina e à RC) e nas propriedades mecânicas, aos 7 dias e 24 meses. Quanto à resistência adesiva CIVC-dentina e CIVC-RC, também não houve diferenças significantes entre as sequências estudadas, apesar da diferença de médias de adesão CIVC-RC entre a SC (0,96 MPa) e SA (5,78 MPa). A SC também apresentou significante maior número de palitos deslocados espontaneamente na interface com a RC antes do teste (77,33%) que a SA (16%). A análise das propriedades mecânicas, aos 7 dias e 24 meses, demonstrou diferenças significantes entre as técnicas. Aos 7 dias, não foi possível obter valores na interface CIVC-RC na SC devido ao grau de deterioração existente enquanto a SA apresentou valores 0,42 GPa (dureza) e 7,50 GPa (módulo de elasticidade). Após 24 meses, a SA apresentou valores de dureza e módulo de elasticidade, respectivamente, 1,24 e 20,96 GPa (CIVC), e 0,40 e 7,05 GPa (interface), enquanto a SC apresentou 0,51 e 8,14 GPa (CIVC) e nenhum valor para interface.Conclusão: A SA apresentou-se como boa opção para a técnica laminada ou do sanduíche quando foi utilizado o CIVMR, e como a melhor opção quando foi utilizado o CIVC.

Page generated in 0.6215 seconds