Avaliação ex vivo da resistência de união de cimento à base de resina epóxica na dentina humana irradiada com laser Er,Cr:YSGG / Ex vivo bond strength of an epoxy resin-based root canal sealer to human root dentin irradiated with Er,Cr:YSGG laserFranceschini, Keila de Almeida 26 February 2015 (has links)
O objetivo do presente estudo foi avaliar, ex vivo, a influência da irradiação do laser Er,Cr:YSGG na resistência de união do material obturador à base de resina epóxica à dentina radicular, por meio do teste de push-out, e na interface dentina/material obturador, por meio de microscopia confocal a laser. Avaliou-se, ainda, a variação de temperatura externa da dentina radicular durante irradiação. Para tanto, 96 caninos foram instrumentados com sistema rotatório K3 até #45/.02 e irrigados com 2 mL de água destilada e deionizada entre os instrumentos utilizados. Os espécimes foram distribuídos em 3 grupos (n=32) em função do protocolo de irrigação final (10 mL): água destilada e deionizada, NaOCl 1% e EDTAC 17%. Em seguida, foram redistribuídos em 4 subgrupos (n=8), de acordo com a irradiação do laser: não irradiado, 2 W/20 Hz, 3 W/20 Hz e 4 W/20 Hz. Durante a irradiação, foram aferidos os valores máximo e mínimo de temperatura na parede radicular externa nos terços cervical, médio e apical e no ápice radicular. Após irradiação, os espécimes foram obturados com cimento AH Plus e guta-percha pela técnica de condensação lateral. Decorridos três vezes o tempo de endurecimento o tempo de do cimento, as raízes foram seccionadas transversalmente em slices de 1 mm de espessura. Dois slices de cada terço foram submetidos ao push-out em máquina universal de ensaios e o tipo de falha foi analisado em lupa estereoscópica e classificado em: adesiva ao material obturador, adesiva à dentina, mista, coesiva no material obturador e coesiva na dentina. O slice restante foi submetido à análise em microscopia confocal a laser, onde avaliou-se a porcentagem de perímetro da secção transversal do canal radicular com tags de cimento e a profundidade dos tags na interface dentina/material obturador de forma quali-quantitativa. Os dados de resistência de união (Mpa) e porcentagem de perímetro com tags foram analisados por meio do teste ANOVA; enquanto os dados da variação de temperatura (ºC) e profundidade dos tags (μm) por meio do teste de Kruskal-Wallis, ambos seguidos de teste de Tukey. A irradiação do laser Er,Cr:YSGG aumentou a resistência de união do cimento obturador à dentina, independente da irrigação final, sendo que os maiores valores foram obtidos para as potência de 3 W (4,02±1,32) e 4 W (4,18±0,98) e os menores valores para o grupo não irradiado (2,64±0,58) (p<0,05). A potência de 2 W (3,28±0,91) apresentou valores intermediários. A irrigação final com EDTAC 17% resultou em maiores valores de resistência de união (4,01±1,02) quando comparado à água destilada (3,11±1,09) e ao NaOCl 1% (3,47±1,18) (p<0,05). Em relação aos terços radiculares, o terço cervical (4,01±1,21) apresentou valor de resistência de união estatisticamente maior que o terço apical (3,04±0,89), enquanto o terço médio apresentou valores intermediários (3,54±1,15) (p<0,05). Em todos os grupos foi observado maior percentual de falhas adesivas e mistas. Nos grupos irradiados com 3 W [21,1 (14,1-27,7)] e 4 W [17,8 (11,9-23,7)] foi observado maior profundidade de tags do material obturador quando comparado ao grupo não irradiado [12,9 (9,0-20,0)]; a potência de 2 W promoveu valores intermediários [15,6 (11,7-23,3)] de profundidade de tags. Os maiores percentuais de perímetro com tags foram observados para os grupos irradiados, não havendo diferença estatística entre eles (p>0,05). O aumento da temperatura foi proporcional ao aumento da potência do laser, não excedendo 3 ºC. Concluiu-se que o laser Er,Cr:YSGG promoveu aumento da resistência de união do cimento à base de resina epóxica à dentina radicular, com maior formação de tags em todas as potências estudadas, principalmente quando associado à irrigação final com EDTAC 17%; o aumento da temperatura durante a irradiação não foi considerado elevado a ponto de prejudicar os tecidos adjacentes. / The aim of this study was to evaluate ex vivo the influence of Er,Cr:YSGG laser irradiation on the bond strength of an epoxy resin-based root canal sealer to root dentin, using the push-out test, and on the dentin/filling material interface, using confocal laser microscopy. The temperature variation on the outer root dentin during irradiation was also evaluated. For this purposes, 96 canines were instrumented with K3 rotary system up to the #45/.02 instrument, irrigating with 2 mL of distilled and deionized water at each change of instrument. The specimens were randomly assigned to 3 groups (n=32), according the final irrigation protocol (10 mL): distilled and deionized water, 1% NaOCl and 17% EDTAC. They were next reassigned into 4 subgroups (n=8), according to the laser irradiation parameters: non-irradiated, 2 W/20 Hz, 3 W/20 Hz and 4 W/20 Hz. During irradiation, the maximum and minimum temperatures were measured on the outer root dentin wall in the cervical, middle and apical thirds as well in the root apex. Following irradiation, the canals were filled with lateral condensation of AH Plus sealer and gutta-percha cones. After a period three times longer than the sealers setting time, the roots were sectioned transversally to obtain 1-mm-thick slices. Two slices from each third were subjected to a push-out test in a universal testing machine and the failure mode was analyzed with stereoscopic lens and classified as: adhesive to the filling material, adhesive to dentin, mixed, cohesive in the filling material and cohesive in dentin. The remaining slice was analyzed by confocal laser microscopy to evaluate the percentage of the perimeter of the root canal cross-section with sealer tags. The depth of tags at the dentin/filling material interface was evaluated in a quali-quantitative manner. Bond strength (MPa) data and the percentage of perimeter with tags were analyzed by ANOVA, while temperature variation (ºC) and tag depth (μm) were analyzed by Kruskal-Wallis test, both followed by Tukeys test. The Er,Cr:YSGG laser irradiation increased sealer bond strength to dentin, regardless of the final irrigation protocol. The highest values were obtained for 3 W (4.02±1.32) and 4 W (4.18±0.98) powers and the lowest for the non-irradiated group (2.64±0.58) (p<0.05). The use of 2 W power (3.28±0.91) resulted in intermediate values. Final irrigation with 17% EDTAC provided higher bond strength (4.01±1.02) compared with distilled water (3.11±1.09) and 1% (NaOCl 3.47±1.18) (p<0.05). Regarding the root thirds, the cervical third (4.01±1.21) presented significantly higher bond strength than the apical third (3.04±0.89), while the middle third presented intermediate values (3.54±1.15) (p<0.05). In all groups, there was a greater percentage of adhesive and mixed failures. In the groups irradiated with 3 W [21.1 (14.1-27.7)] and 4 W [17.8 (11.9-23.7)], it was observed a greater depth of filling material tags compared with the non-irradiated group [12.9 (9.0-20.0)]; 2 W power produced intermediate tag depth values [15.6 (11.7-23.3)]. The greatest percentage of canal perimeter with sealer tags was observed in the irradiated groups, with no statistically significant difference among them (p>0.05). The temperature rise was proportional to the increase of laser power, not surpassing 3 °C. It was therefore concluded that Er,Cr:YSGG laser irradiation increased the bond strength of an epoxy resin-based sealer to root dentin, with greater formation of sealer tags when for all tested powers, especially if combined with final irrigation with 17% EDTAC; temperature rise during irradiation was not considered high enough to cause harmful effects to the adjacent tissues.
|
2 |
Avaliação ex vivo da resistência de união de cimento à base de resina epóxica na dentina humana irradiada com laser Er,Cr:YSGG / Ex vivo bond strength of an epoxy resin-based root canal sealer to human root dentin irradiated with Er,Cr:YSGG laserKeila de Almeida Franceschini 26 February 2015 (has links)
O objetivo do presente estudo foi avaliar, ex vivo, a influência da irradiação do laser Er,Cr:YSGG na resistência de união do material obturador à base de resina epóxica à dentina radicular, por meio do teste de push-out, e na interface dentina/material obturador, por meio de microscopia confocal a laser. Avaliou-se, ainda, a variação de temperatura externa da dentina radicular durante irradiação. Para tanto, 96 caninos foram instrumentados com sistema rotatório K3 até #45/.02 e irrigados com 2 mL de água destilada e deionizada entre os instrumentos utilizados. Os espécimes foram distribuídos em 3 grupos (n=32) em função do protocolo de irrigação final (10 mL): água destilada e deionizada, NaOCl 1% e EDTAC 17%. Em seguida, foram redistribuídos em 4 subgrupos (n=8), de acordo com a irradiação do laser: não irradiado, 2 W/20 Hz, 3 W/20 Hz e 4 W/20 Hz. Durante a irradiação, foram aferidos os valores máximo e mínimo de temperatura na parede radicular externa nos terços cervical, médio e apical e no ápice radicular. Após irradiação, os espécimes foram obturados com cimento AH Plus e guta-percha pela técnica de condensação lateral. Decorridos três vezes o tempo de endurecimento o tempo de do cimento, as raízes foram seccionadas transversalmente em slices de 1 mm de espessura. Dois slices de cada terço foram submetidos ao push-out em máquina universal de ensaios e o tipo de falha foi analisado em lupa estereoscópica e classificado em: adesiva ao material obturador, adesiva à dentina, mista, coesiva no material obturador e coesiva na dentina. O slice restante foi submetido à análise em microscopia confocal a laser, onde avaliou-se a porcentagem de perímetro da secção transversal do canal radicular com tags de cimento e a profundidade dos tags na interface dentina/material obturador de forma quali-quantitativa. Os dados de resistência de união (Mpa) e porcentagem de perímetro com tags foram analisados por meio do teste ANOVA; enquanto os dados da variação de temperatura (ºC) e profundidade dos tags (μm) por meio do teste de Kruskal-Wallis, ambos seguidos de teste de Tukey. A irradiação do laser Er,Cr:YSGG aumentou a resistência de união do cimento obturador à dentina, independente da irrigação final, sendo que os maiores valores foram obtidos para as potência de 3 W (4,02±1,32) e 4 W (4,18±0,98) e os menores valores para o grupo não irradiado (2,64±0,58) (p<0,05). A potência de 2 W (3,28±0,91) apresentou valores intermediários. A irrigação final com EDTAC 17% resultou em maiores valores de resistência de união (4,01±1,02) quando comparado à água destilada (3,11±1,09) e ao NaOCl 1% (3,47±1,18) (p<0,05). Em relação aos terços radiculares, o terço cervical (4,01±1,21) apresentou valor de resistência de união estatisticamente maior que o terço apical (3,04±0,89), enquanto o terço médio apresentou valores intermediários (3,54±1,15) (p<0,05). Em todos os grupos foi observado maior percentual de falhas adesivas e mistas. Nos grupos irradiados com 3 W [21,1 (14,1-27,7)] e 4 W [17,8 (11,9-23,7)] foi observado maior profundidade de tags do material obturador quando comparado ao grupo não irradiado [12,9 (9,0-20,0)]; a potência de 2 W promoveu valores intermediários [15,6 (11,7-23,3)] de profundidade de tags. Os maiores percentuais de perímetro com tags foram observados para os grupos irradiados, não havendo diferença estatística entre eles (p>0,05). O aumento da temperatura foi proporcional ao aumento da potência do laser, não excedendo 3 ºC. Concluiu-se que o laser Er,Cr:YSGG promoveu aumento da resistência de união do cimento à base de resina epóxica à dentina radicular, com maior formação de tags em todas as potências estudadas, principalmente quando associado à irrigação final com EDTAC 17%; o aumento da temperatura durante a irradiação não foi considerado elevado a ponto de prejudicar os tecidos adjacentes. / The aim of this study was to evaluate ex vivo the influence of Er,Cr:YSGG laser irradiation on the bond strength of an epoxy resin-based root canal sealer to root dentin, using the push-out test, and on the dentin/filling material interface, using confocal laser microscopy. The temperature variation on the outer root dentin during irradiation was also evaluated. For this purposes, 96 canines were instrumented with K3 rotary system up to the #45/.02 instrument, irrigating with 2 mL of distilled and deionized water at each change of instrument. The specimens were randomly assigned to 3 groups (n=32), according the final irrigation protocol (10 mL): distilled and deionized water, 1% NaOCl and 17% EDTAC. They were next reassigned into 4 subgroups (n=8), according to the laser irradiation parameters: non-irradiated, 2 W/20 Hz, 3 W/20 Hz and 4 W/20 Hz. During irradiation, the maximum and minimum temperatures were measured on the outer root dentin wall in the cervical, middle and apical thirds as well in the root apex. Following irradiation, the canals were filled with lateral condensation of AH Plus sealer and gutta-percha cones. After a period three times longer than the sealers setting time, the roots were sectioned transversally to obtain 1-mm-thick slices. Two slices from each third were subjected to a push-out test in a universal testing machine and the failure mode was analyzed with stereoscopic lens and classified as: adhesive to the filling material, adhesive to dentin, mixed, cohesive in the filling material and cohesive in dentin. The remaining slice was analyzed by confocal laser microscopy to evaluate the percentage of the perimeter of the root canal cross-section with sealer tags. The depth of tags at the dentin/filling material interface was evaluated in a quali-quantitative manner. Bond strength (MPa) data and the percentage of perimeter with tags were analyzed by ANOVA, while temperature variation (ºC) and tag depth (μm) were analyzed by Kruskal-Wallis test, both followed by Tukeys test. The Er,Cr:YSGG laser irradiation increased sealer bond strength to dentin, regardless of the final irrigation protocol. The highest values were obtained for 3 W (4.02±1.32) and 4 W (4.18±0.98) powers and the lowest for the non-irradiated group (2.64±0.58) (p<0.05). The use of 2 W power (3.28±0.91) resulted in intermediate values. Final irrigation with 17% EDTAC provided higher bond strength (4.01±1.02) compared with distilled water (3.11±1.09) and 1% (NaOCl 3.47±1.18) (p<0.05). Regarding the root thirds, the cervical third (4.01±1.21) presented significantly higher bond strength than the apical third (3.04±0.89), while the middle third presented intermediate values (3.54±1.15) (p<0.05). In all groups, there was a greater percentage of adhesive and mixed failures. In the groups irradiated with 3 W [21.1 (14.1-27.7)] and 4 W [17.8 (11.9-23.7)], it was observed a greater depth of filling material tags compared with the non-irradiated group [12.9 (9.0-20.0)]; 2 W power produced intermediate tag depth values [15.6 (11.7-23.3)]. The greatest percentage of canal perimeter with sealer tags was observed in the irradiated groups, with no statistically significant difference among them (p>0.05). The temperature rise was proportional to the increase of laser power, not surpassing 3 °C. It was therefore concluded that Er,Cr:YSGG laser irradiation increased the bond strength of an epoxy resin-based sealer to root dentin, with greater formation of sealer tags when for all tested powers, especially if combined with final irrigation with 17% EDTAC; temperature rise during irradiation was not considered high enough to cause harmful effects to the adjacent tissues.
|
3 |
Avaliação longitudinal da adesão à dentina irradiado pelo laser de Er,Cr:YSGG / Longitudinal evaluation of adherence to dentin irradiated by laser Er, Cr: YSGG.Goldman, Juliana Elston 01 December 2009 (has links)
O laser de Er,Cr:YSGG se apresenta como um aliado aos procedimentos minimamente invasivos. Porém, pouco se sabe sobre a longevidade da resistência de união à dentina irradiada por este equipamento. Dessa forma, o objetivo deste estudo foi avaliar a resistência de união à dentina irradiada após 90 dias de armazenamento. Para tanto, foram utilizados 64 molares humanos hígidos, que tiveram as superfícies oclusais desgastadas até a exposição de uma superfície de dentina. Esta superfície foi tratada com: abrasão com lixa SiC 600# (controle) e irradiação com o laser de Er,Cr:YSGG em 2W (90,9 J/cm2) ou 4W (181,8 J/cm2). Foram utilizados os seguintes sistemas adesivos: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) ou Clearfil S3 (Kuraray), e a confecção de um bloco de resina composta Z250-3MESPE. Os dentes foram seccionados para a obtenção de palitos para o teste de microtração. Metade dos palitos foi ensaiada imediatamente, e a outra metade após 90 dias de armazenamento em água destilada. Os resultados mostraram que em todos os grupos em que foi utilizado o laser Er,Cr:YSGG apresentaram os menores valores de resistência adesiva. Com exceção do grupo controle/Clearfil S3, todos os grupos apresentaram decréscimo nos valores de resistência adesiva após os 90 dias de armazenamento. Entre os sistemas adesivos utilizados, o Single Bond apresentou os melhores valores de resistência adesiva, demonstrando maior estabilidade frente aos 90 dias de desafio/armazenamento. / In the minimally invasive dentistry, the Er,Cr:YSGG laser has been considered as an efficient equipment. However, little is known about the longevity of the bond strength to irradiated dentin. So, the objective of this study was to evaluate the bond strength values to laser irradiated dentin after 90 days storage. Sixty-four sound human molars were used. A flat coronal dentin surface was obtained by removing the oclusal enamel with a slow speed diamond saw. Dentin surfaces were treated with: abrasion with SiC 600# (control group) and laser irradiation with Er,Cr:YSGG in 2W or 4W. Subsequently, adhesive systems were used: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) or ClearfilS3 (Kuraray). After adhesive procedures, a block of Z250-3MESPE composite resin was build up on each tooth. The teeth were sectioned in order to obtain samples for the microtensile bond strength test. Half of the samples was tested immediately, and the other half were stored for 90 days in distilled water. The results showed that all the groups in which laser was used presenter lower bond strength values. With the exception of Clearfil S3/control group, all groups showed weaker bond strength after 90 days of storage. Among all the adhesives systems used, Single Bond presented the best results, showing more stability after 90 days of storage.
|
4 |
Avaliação longitudinal da adesão à dentina irradiado pelo laser de Er,Cr:YSGG / Longitudinal evaluation of adherence to dentin irradiated by laser Er, Cr: YSGG.Juliana Elston Goldman 01 December 2009 (has links)
O laser de Er,Cr:YSGG se apresenta como um aliado aos procedimentos minimamente invasivos. Porém, pouco se sabe sobre a longevidade da resistência de união à dentina irradiada por este equipamento. Dessa forma, o objetivo deste estudo foi avaliar a resistência de união à dentina irradiada após 90 dias de armazenamento. Para tanto, foram utilizados 64 molares humanos hígidos, que tiveram as superfícies oclusais desgastadas até a exposição de uma superfície de dentina. Esta superfície foi tratada com: abrasão com lixa SiC 600# (controle) e irradiação com o laser de Er,Cr:YSGG em 2W (90,9 J/cm2) ou 4W (181,8 J/cm2). Foram utilizados os seguintes sistemas adesivos: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) ou Clearfil S3 (Kuraray), e a confecção de um bloco de resina composta Z250-3MESPE. Os dentes foram seccionados para a obtenção de palitos para o teste de microtração. Metade dos palitos foi ensaiada imediatamente, e a outra metade após 90 dias de armazenamento em água destilada. Os resultados mostraram que em todos os grupos em que foi utilizado o laser Er,Cr:YSGG apresentaram os menores valores de resistência adesiva. Com exceção do grupo controle/Clearfil S3, todos os grupos apresentaram decréscimo nos valores de resistência adesiva após os 90 dias de armazenamento. Entre os sistemas adesivos utilizados, o Single Bond apresentou os melhores valores de resistência adesiva, demonstrando maior estabilidade frente aos 90 dias de desafio/armazenamento. / In the minimally invasive dentistry, the Er,Cr:YSGG laser has been considered as an efficient equipment. However, little is known about the longevity of the bond strength to irradiated dentin. So, the objective of this study was to evaluate the bond strength values to laser irradiated dentin after 90 days storage. Sixty-four sound human molars were used. A flat coronal dentin surface was obtained by removing the oclusal enamel with a slow speed diamond saw. Dentin surfaces were treated with: abrasion with SiC 600# (control group) and laser irradiation with Er,Cr:YSGG in 2W or 4W. Subsequently, adhesive systems were used: Adper Single Bond (3MESPE), Clearfil SE (Kuraray) or ClearfilS3 (Kuraray). After adhesive procedures, a block of Z250-3MESPE composite resin was build up on each tooth. The teeth were sectioned in order to obtain samples for the microtensile bond strength test. Half of the samples was tested immediately, and the other half were stored for 90 days in distilled water. The results showed that all the groups in which laser was used presenter lower bond strength values. With the exception of Clearfil S3/control group, all groups showed weaker bond strength after 90 days of storage. Among all the adhesives systems used, Single Bond presented the best results, showing more stability after 90 days of storage.
|
5 |
Influência do condicionamento da dentina na resistência de união de cimento de ionômero de vidro / Er,Cr:YSGG Laser Dentin Conditioning Influence on Glass Ionomer Cement Bond StrengthGarbui, Bruna Uglik 05 July 2012 (has links)
Objetivos: avaliar o efeito de 3 parâmetros de condicionamento da dentina utilizando o laser de Er,Cr;YSGG (2,78m) na resistência de união (RU) de cimento de ionômero de vidro convencional (CIV). Materiais e métodos: Foram utilizados neste estudo 68 terceiros molares humanos, divididos aleatoriamente em 4 grupos (n=17/ grupo): G1 (grupo controle): nenhum tipo de condicionamento; G2: condicionamento com laser de Er,Cr;YSGG 0,5W, 25mJ, 20Hz ou G3: 1,0W, 50mJ, 20Hz e G4: 1,5W, 75mJ, 20Hz. Dois dentes em cada um dos grupos foram observados em microscopia eletrônica de varredura (MEV) para identificar as características morfológicas dos diferentes condicionamentos de superfície realizados. Os outros 15 dentes/grupo, foram preparados para ensaio de RU, obtendo uma superfície plana de dentina onde foram construídos 3 (n=45/grupo) corpos de prova em forma de cilindro (1mm de diâmetro X 0,5mm de altura) utilizando o ionômero de vidro Ketac Molar Easymix- 3M ESPE. Após o armazenamento em água destilada por 24h a 37oC os espécimes foram ensaiados pelo teste de microcisalhamento. Os valores finais de resistência adesiva foram calculados e expressos em Mega Pascal (MPa). Os dados foram coletados e analisados por ANOVA (p<0,001). Resultados: Os espécimes do G2 apresentaram os maiores resultados de RU (10,50MPa ±0,84), seguido pelo G1 (4.77MPa ±0.59), G3 (3.32MPa ±0.39) e G4 (2,94MPa ±0,50) que não apresentaram diferença estatisticamente significante quanto comparados entre si. A análise em MEV do G1 mostrou camada de smear ao longo de toda a superfície de dentina, enquanto nos outros grupos observou-se túbulos dentinários abertos, característicos na irradiação com laser de Er,Cr:YSGG. Os pulsos do laser no G2 eram facilmente distinguidos, o que não acontecia nos grupos G3 e G4, sugerindo que parâmetros de energia maiores podem causar efeitos mais extensos à estrutura da dentina. Na análise do padrão de fratura, todos os grupos apresentaram maior porcentagem de fratura adesiva G1:73,3%, G2:48,9% G3:66,7% e G4:64,4%. O tipo de fratura mista foi proporcional ao aumento da RU (G1:24,4%, G2:46,7%, G3:20,0% e G4:17,8%). Conclusão: O condicionamento da dentina com o laser de Er,Cr:YSGG na potência de 0,5W aumentou significativamente a RU do CIV à dentina, enquanto os demais parâmetros testados reduziram a RU. / Objective: To evaluate the effect of 3 dentin conditioning parameters of Er,Cr:YSGG laser (2,78 m) on the bond strength (BS) of conventional glass ionomer cement (CGIC). Methods: A total of 68 third molars were divided into four groups and was subjected to one of the following pretreatments: G1- the control group, no pretreatment was realized; G2, G3 and G4 were pretreated with Er,Cr:YSGG laser irradiation at 0.5 W, 25 mJ, 9 J/cm2, and 20 Hz (G2); 1.0 W, 50 mJ, 18 J/cm2, and 20 Hz (G3); and at 1.5 W, 75 mJ, 27 J/cm2, and 20 Hz (G4). A scanning electron microscopy (SEM) evaluation (n=2) of pretreated dentine and a microshear bond strength test (n=15) were performed after 24h of water immersion. To build the specimens (each of which was 1 mm in diameter) for the microshear test, CGIC (Ketac Molar Easy Mix) was used. The data were analysed by one-way ANOVA (p<0.001). Results: The G2 specimens presented the highest BS results (10.50 MPa ± 0.84), and G1 had the next highest average BS values (4.77 MPa ± 0.59). G3 (3.32 MPa ± 0.39) and G4 (2.94 MPa ± 0.50) demonstrated the lowest BS values, although the BS difference between these groups was not statistically significant (p>0.001). The SEM analysis of G1 revealed that the smear layer covered the entire dentine surface, whereas in groups G2, G3, and G4, irregular dentine was detected that possessed the open dentinal tubules and protruded peritubular dentine that are the characteristic results of laser irradiation. Laser pulses could easily be distinguished in G2 but not in G3 and G4, suggesting that higher energy parameters can broadly disrupt dentine structure and thereby affect the bonding of dentine to GIC. Conclusion: Dentine pretreatment with an Er,Cr:YSGG laser at a power of 0.5 W increased the BS of conventional GIC.
|
6 |
Influência do condicionamento da dentina na resistência de união de cimento de ionômero de vidro / Er,Cr:YSGG Laser Dentin Conditioning Influence on Glass Ionomer Cement Bond StrengthBruna Uglik Garbui 05 July 2012 (has links)
Objetivos: avaliar o efeito de 3 parâmetros de condicionamento da dentina utilizando o laser de Er,Cr;YSGG (2,78m) na resistência de união (RU) de cimento de ionômero de vidro convencional (CIV). Materiais e métodos: Foram utilizados neste estudo 68 terceiros molares humanos, divididos aleatoriamente em 4 grupos (n=17/ grupo): G1 (grupo controle): nenhum tipo de condicionamento; G2: condicionamento com laser de Er,Cr;YSGG 0,5W, 25mJ, 20Hz ou G3: 1,0W, 50mJ, 20Hz e G4: 1,5W, 75mJ, 20Hz. Dois dentes em cada um dos grupos foram observados em microscopia eletrônica de varredura (MEV) para identificar as características morfológicas dos diferentes condicionamentos de superfície realizados. Os outros 15 dentes/grupo, foram preparados para ensaio de RU, obtendo uma superfície plana de dentina onde foram construídos 3 (n=45/grupo) corpos de prova em forma de cilindro (1mm de diâmetro X 0,5mm de altura) utilizando o ionômero de vidro Ketac Molar Easymix- 3M ESPE. Após o armazenamento em água destilada por 24h a 37oC os espécimes foram ensaiados pelo teste de microcisalhamento. Os valores finais de resistência adesiva foram calculados e expressos em Mega Pascal (MPa). Os dados foram coletados e analisados por ANOVA (p<0,001). Resultados: Os espécimes do G2 apresentaram os maiores resultados de RU (10,50MPa ±0,84), seguido pelo G1 (4.77MPa ±0.59), G3 (3.32MPa ±0.39) e G4 (2,94MPa ±0,50) que não apresentaram diferença estatisticamente significante quanto comparados entre si. A análise em MEV do G1 mostrou camada de smear ao longo de toda a superfície de dentina, enquanto nos outros grupos observou-se túbulos dentinários abertos, característicos na irradiação com laser de Er,Cr:YSGG. Os pulsos do laser no G2 eram facilmente distinguidos, o que não acontecia nos grupos G3 e G4, sugerindo que parâmetros de energia maiores podem causar efeitos mais extensos à estrutura da dentina. Na análise do padrão de fratura, todos os grupos apresentaram maior porcentagem de fratura adesiva G1:73,3%, G2:48,9% G3:66,7% e G4:64,4%. O tipo de fratura mista foi proporcional ao aumento da RU (G1:24,4%, G2:46,7%, G3:20,0% e G4:17,8%). Conclusão: O condicionamento da dentina com o laser de Er,Cr:YSGG na potência de 0,5W aumentou significativamente a RU do CIV à dentina, enquanto os demais parâmetros testados reduziram a RU. / Objective: To evaluate the effect of 3 dentin conditioning parameters of Er,Cr:YSGG laser (2,78 m) on the bond strength (BS) of conventional glass ionomer cement (CGIC). Methods: A total of 68 third molars were divided into four groups and was subjected to one of the following pretreatments: G1- the control group, no pretreatment was realized; G2, G3 and G4 were pretreated with Er,Cr:YSGG laser irradiation at 0.5 W, 25 mJ, 9 J/cm2, and 20 Hz (G2); 1.0 W, 50 mJ, 18 J/cm2, and 20 Hz (G3); and at 1.5 W, 75 mJ, 27 J/cm2, and 20 Hz (G4). A scanning electron microscopy (SEM) evaluation (n=2) of pretreated dentine and a microshear bond strength test (n=15) were performed after 24h of water immersion. To build the specimens (each of which was 1 mm in diameter) for the microshear test, CGIC (Ketac Molar Easy Mix) was used. The data were analysed by one-way ANOVA (p<0.001). Results: The G2 specimens presented the highest BS results (10.50 MPa ± 0.84), and G1 had the next highest average BS values (4.77 MPa ± 0.59). G3 (3.32 MPa ± 0.39) and G4 (2.94 MPa ± 0.50) demonstrated the lowest BS values, although the BS difference between these groups was not statistically significant (p>0.001). The SEM analysis of G1 revealed that the smear layer covered the entire dentine surface, whereas in groups G2, G3, and G4, irregular dentine was detected that possessed the open dentinal tubules and protruded peritubular dentine that are the characteristic results of laser irradiation. Laser pulses could easily be distinguished in G2 but not in G3 and G4, suggesting that higher energy parameters can broadly disrupt dentine structure and thereby affect the bonding of dentine to GIC. Conclusion: Dentine pretreatment with an Er,Cr:YSGG laser at a power of 0.5 W increased the BS of conventional GIC.
|
7 |
Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laserRamos, Thaysa Monteiro 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
|
8 |
Avaliação in vitro da morfologia e da resistência de união de adesivos à dentina humana hígida ou submetida à ciclagem erosiva e irradiada com os lasers de Er:YAG e Er,Cr:YSGG / In vitro evaluation of the morphology and the bond strength of adhesives to sound and artificially eroded human dentin irradiated with Er:YAG and Er,Cr:YSGG laserThaysa Monteiro Ramos 04 July 2012 (has links)
A erosão dental provoca alterações histológicas complexas na dentina e, apesar do aumento da ocorrência desta patologia na última década, a literatura apresenta poucos estudos sobre a adesão na dentina erodida. Com o aprimoramento da tecnologia e o conhecimento de que os lasers de érbio apresentam grande afinidade pela água e hidroxiapatita, sua utilização tem sido considerada um método alternativo para tratamento da superfície dentinária antes dos procedimentos adesivos. Assim, o objetivo deste trabalho in vitro foi avaliar o efeito de diferentes tratamentos de superfície (ponta diamantada, laser de Er:YAG 2,94 m, 60 mJ, 2 Hz, 0,2 W, 19,3 J/cm2 - e laser de Er,Cr:YSGG 2,78 m, 50 mJ, 30 Hz, 1,5 W, 4,5 J/cm2), prévios ao tratamento restaurador, tanto na dentina humana hígida quanto na dentina artificialmente erodida. Metade das amostras foi submetida à ciclagem erosiva, a qual foi realizada durante 5 dias por meio da imersão em solução de ácido cítrico 0,05 M (pH 2,3, 10 minutos, 6x/dia) e solução supersaturada (pH 7,0, 60 minutos entre os ataques ácidos). Na fase experimental 1, 32 fragmentos de dentina foram divididos aleatoriamente em 8 grupos (n = 4) e com o auxílio da Microscopia Eletrônica de Varredura (MEV), realizou-se a análise da morfologia da superfície da dentina hígida e da submetida à ciclagem erosiva, após os diferentes tratamentos de superfície. Na fase experimental 2, 192 terceiros molares humanos foram divididos aleatoriamente em 2 grupos (dentina hígida e dentina submetida à ciclagem erosiva) e 8 subgrupos (n = 12) para avaliação da resistência de união entre as superfícies tratadas e 2 sistemas adesivos (01 autocondicionante e 01 com condicionamento ácido prévio), por meio do ensaio de microtração e da análise do padrão de fratura. Para o ensaio de microtração, blocos de resina composta microhíbrida foram confeccionados na superfície de dentina e, após armazenados em água destilada-deionizada por 24h (37oC), palitos foram obtidos para serem tracionados na máquina de ensaio universal (0,5mm/min). A análise do padrão de fratura realizada em microscópio ótico (40x) e as avaliações das eletromicrografias foram feitas de forma descritiva. Os valores obtidos de resistência de união(MPa) foram submetidos aos testes de ANOVA (dois fatores) e de comparações múltiplas de Tukey (p<0,05). A análise morfológica de superfície mostrou alterações significativas da dentina hígida e da dentina artificialmente erodida, submetidas aos diferentes tratamentos de superfície. Quanto à resistência de união, na dentina hígida, o grupo controle, tanto do sistema autocondicionante (54,69 ± 7,80 MPa) quanto do condicionamento ácido total (47,36 ± 9,35 MPa), apresentou valores significativamente maiores que os outros grupos, sendo, porém, diferentes entre si. Na dentina erodida, a maior resistência de união foi alcançada com o grupo tratado com o laser de Er,Cr:YSGG associado ao adesivo autocondicionante (28,26 ± 9,22 MPa), o qual foi significativamente diferente de todos demais grupos. Com base nos parâmetros de irradiação utilizados neste estudo, pode-se concluir que em dentina hígida, os tratamentos de superfície com os lasers de Er:YAG e Er,Cr:YSGG apresentaram resultados de adesão inferiores, mas satisfatórios, em relação ao grupo controle. Já em substrato dentinário erodido, a irradiação com laser de Er,Cr:YSGG, associada ao uso de sistema adesivo autocondicionante, promoveu efeito positivo para a adesão à resina composta. / Dental erosion can cause complex histological changes in dentin and, despite the increase in its incidence during the last decade, limited information is available regarding adhesion to eroded dentin. With improvements in technology and due to the fact that the erbium lasers have high affinity to water and hydroxyapatite, the use of laser can consist on an alternative for the treatment of dentin surface before adhesive procedures. The aim of this in vitro study was to evaluate the effect of different surface treatments (diamond bur, Er:YAG laser 2.94 m, 60 mJ, 2 Hz, 0.2 W, 19.3 J/cm2 - and Er,Cr:YSGG laser 2.78 m, 50 mJ, 30 Hz, 1.5 W, 4.5 J/cm2) prior to restorative treatment, in sound and artificially eroded human dentin. Half of the samples was submitted to the erosive cycling, which was performed by immersion in 0.05 M citric acid (pH 2.3, 10 min, 6x/day) and in supersaturated solution (pH 7.0, 1h, between acid attacks), during 5 days. In phase 1, 32 dentin fragments were randomly divided into 8 groups (n = 4). The analysis of surface morphology of both sound and eroded dentin was performed by Scanning Electron Microscopy (SEM), after the different surface treatments. In phase 2, 192 human third molars were randomly divided into 2 groups (sound and eroded dentin) and 8 subgroups (n=12) to evaluate the bond strength between the treated surfaces and composite resin, with two adhesive systems (self-etching and total-etching) by means of the microtensile bond strength (TBS) test and fracture pattern analysis. For the microtensile bond strength test, blocks of composite resin were bonded to the samples and, after 24 h-storage in distilled/deionized water (37°C), stick-shapped samples were obtained and submitted to TBS test in a universal testing machine (0.5 mm/min). The fracture pattern was performed with an optical microscopy (40x) and the evaluations of the electromicrographs were made under a descriptive mode. The bond strength values (MPa) were analyzed by two-way ANOVA and Tukey tests ( = 0.05). In sound dentin, for the control group, both self-etching (54.69 ± 7.8 MPa) and total-etching adhesive system (47.36 ± 9.3 MPa) showed significantly higher values than all other groups (p<0.05), even though they differ from each other. However, in eroded dentin groups, the self-etching on the samples treated with the Er,Cr:YSGG laser presented the highest mean (28.3 ± 9.2 MPa), which was statistically significant higher than all the other treatments (p<0.05). Based on the irradiation parameters considered for this study, it can be concluded that in healthy dentin, the surface treatment with Er:YAG and Er,Cr:YSGG irradiation showed bonding values lower than the control group, but they presented satisfactory results. However, in eroded dentin, the use of Er,Cr:YSGG laser, associated with the self-etching adhesive system, promoted positive effect on adhesion to composite resin.
|
9 |
Influência do tratamento da superfície interna da cerâmica sob diferentes parâmetros de irradiação com laser de Er,Cr:YSGG / Influence of the treatment of the internal surface of the ceramic on different parameters of laser irradiation Er,Cr:YSGGInca, Hector Eduardo Cepeda 06 November 2018 (has links)
Objetivos: Este estudo teve como objetivo avaliar a resistência de união entre cimento resinoso e as amostras de zircônia irradiadas como o laser de Er,Cr:YSGG em quatro parâmetros. Foram utilizadas 78 unidades experimentais (12,4 mm x 7,6 mm x 1,6 mm) a partir de blocos de Y-TZP (zircônia tetragonal estabilizada com ítrio) pré-sinterizados. A fim de obter superfícies padronizadas, os espécimes foram lixados com uma sequência decrescente de lixas (600, 1200, 1500). Em seguida, os blocos foram sinterizados em um forno específico, de acordo com as recomendações do fabricante. Os grupos experimentais foram compostos a partir de um fator de variação - tratamento de superfície. Foram formados 6 grupos experimentais (n=13) Controle, sem tratamento de superfície, grupo Rocatec, com tratamento triboquímico (Rocatec System Plus 3M ESPE), e 4 grupos laser (Waterlase Iplus Biolase Inc. Irvine, CA, EUA comprimento de onda 2780nm, 700?s, de 50% de ar e 50% de água, ponta MZ6 600?m): L3W 20Hz (53,57J/cm2), grupo L3W 50Hz (21,43J/cm2), grupo L6W 20Hz (107,14J/cm2), grupo L6W 50Hz (42,68J/cm2). Um espécime de cada grupo foi analisado através de microscopia eletrônica de varredura MEV (10000x). Após dos tratamentos de superfície, em cada bloco de zircônia foram colados 6 cilindros de resina usando cimento dual contendo MDP (Panavia F 2.0). Todas as amostras foram armazenadas em água destilada a 37ºC. O teste de microcisalhamento foi feito na máquina de ensaio universal (Instron 5565 EUA). Três dos 6 tubos colados em cada bloco foram avaliados depois de 24 horas de armazenamento em água a 37ºC e os 3 restantes foram avaliados depois de 2000 ciclos térmicos (5ºC - 30ºC). O tipo de falha foi determinado através de estereomicroscópio. Os dados foram analisados pelos testes de análise de variância (ANOVA) e de Tukey com um nivel de significância de p<0,01. Resultados: O grupo controle positivo (ROCATEC) apresentou diferença significativa (p <0,001) com os demais grupos. Quando foi simulado o envelhecimento térmico (termociclagem), todos os grupos apresentaram diferença significativa (p <0,001) na resistência de união comparada com o protocolo sem termociclagem. O tratamento de superfície convencional ainda é preconizado como uma alternativa válida para melhorar a resistência de união na zircônia. O uso de laser de Er,Cr:YSGG com uma largura de pulso de 700?s dentro dos parâmetros estudados não promoveu mudanças na superfície de zircônia que favorecessem a adesão com cimento resinoso. A termociclagem influenciou negativamente em todos os grupos experimentais. / This study aimed to evaluate the bond strength between resin cement and the irradiated zirconia samples a the Er, Cr: YSGG laser in four parameters. It was used 78 experimental units (12.4mm x 7.6mm x 1.6mm) from pre-sintered Y-TZP (Ytriumstabilized Tetragonal Zirconia) blocks. In order to obtain standardized surfaces the specimens were sanded with a decreasing sanding sequence (600,1200,1500). Then, the blocks form sintered in a specific oven, according to the manufacturer\'s recommendations. The experimental groups were composed of a variation factor - the surface treatment. Thus, 6 experimental groups were formed (n=13). Control, without surface treatment, the Rocatec group, with triboquimic treatment (Rocatec System Plus 3M ESPE), and 4 laser groups (Waterlase Iplus Biolase Inc. Irvine, CA USA wavelength 2780nm, 700?s, 50% air and 50% water, MZ6 600?m tip): L3W 20Hz (53.57J / cm2), L3W 50Hz group (21.43J / cm2), L6W 20Hz group (107.14J / cm2), group L6W 50Hz (42.68J / cm2). One specimen from each group was analyzed by Scanning Electron Microscopy (10000x). After the surface treatments, 6 resin cylinders were bonded to each zirconia block using dual cement containing MDP (Panavia F 2.0). All samples were stored in distilled water at 37 ° C. The micro-shear test was performed on the universal test machine (Instron 5565 USA). 3 of the 6 tubes pasted in each block were evaluated after 24 hours of storage in 37 ° C water and the remaining 3 were evaluated after 2000 thermal cycles (5 ° C - 30 ° C). The type of failure was determined by stereomicroscope. The data were analyzed by a test for analysis of variance (ANOVA) and tukey with a significance level of p <0.01. Results: The positive control group (ROCATEC), evaluated immediately after cementation, showed a better bond strength and there was no significant difference when thermal aging was simulated (thermocycling), nor did it differ significantly from the groups without thermocycling of 3w20Hz or 6w50hz. Conventional surface treatment is still advocated as a valid alternative to improve bond strength in zirconia. The use of Er, Cr: YSGG laser with a pulse width of 700?s within the studied parameters did not promote changes in the zirconia surface that favored adhesion with resin cement. Thermocycling influenced negatively all experimental groups.
|
10 |
Thermal Changes in the Dental Pulp During Er,Cr:YSGG Laser Removal of IPS e.max Press Lithium Disilicate VeneersPhillips, Wesley B. 22 June 2012 (has links)
No description available.
|