• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 12
  • 8
  • 8
  • 8
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo de propriedades físico-químicas de um novo cimento obturador endodôntico

Santos, Alaílson Domingos dos [UNESP] 17 April 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:32:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-04-17Bitstream added on 2014-06-13T20:42:51Z : No. of bitstreams: 1 santos_ad_dr_bauru.pdf: 5050501 bytes, checksum: 953944123d570eb83506e96c96c8073d (MD5) / Os cimentos odontológicos a base de Cimento Portland, vêm desde a década passada sendo exaustivamente analisados em pesquisas científicas. Comercialmente como exemplo, temos o ProRoot MTA (Tulsa Dental, Oklahoma - USA) e o MTA-Angelus (Angelus Soluções Odontológicas, Londrina - Brazil). Ambos possuem inúmeras qualidades, porém tem inadequado tempo de presa e uma consistência que dificulta o seu manuseio por parte dos clínicos. O Grupo Vidros e Cerâmicas da UNESP - Ilha Solteira desenvolveu um cimento com as mesmas aplicações clínicas do MTA. Estudos recentes mostram que este material (denominado CER), possui propriedades físico-químicas semelhantes àquelas apresentadas pelo MTA. Atualmente tem-se tentado utilizar o cimento MTA como cimento obturador endodôntico, porém, características físicas dificultam seu uso para este fim. A proposta deste trabalho foi mostrar o desenvolvimento de um novo cimento obturador endodôntico, partindo da formulação do CER e testar algumas propriedades físico químicas deste material, tendo como comparação o cimento endodôntico comercial Sealer 26® (Dentsply Ind. E Com. Ltda., Petrópolis-Brazil). Os resultados obtidos mostraram que o cimento CEOE comparado com o Sealer 26®, tem um tempo de presa menor, maior liberação de íons, maior dureza e semelhante adesividade, solubilidade e selabilidade. / In the last decade, the dental cements based on Portland cement have been exhaustively investigated scientifically. Commercially is available the ProRoot MTA (Tulsa Dental, Oklahoma - USA) and MTA-Angelus (Angelus Soluções Dental, Londrina - Brazil) cements. In spite of the excellent physical, chemical and biological properties, one of the main disadvantages with using MTA is its extended setting time and difficult handling. Recently, the Glass and Ceramics group developed an experimental cement with the same clinical applications of MTA. Recent investigations showed that this material (entitled CER) it has physico-chemical properties similar those of the MTA. At present its biological properties are being investigated. One of the principal functions of the MTA is to seal the communications between the root and extern surface of the teeth. Recent studies have been showing that the physical characteristics of the MTA make difficult his use as root-filling cement. The purpose of this study was to developed new endodontic cement based on the formulation of the CER material. The properties evaluate in this study were: setting time, ions release, adhesion, hardness, solubility and sealing ability. The obtained results were compared with the Sealer 26® (Dentsply Ind. e Com. Ltda, Petrópolis-Brazil).
2

Efeito da adição de fosfato dicálcico dihidratado (DCPD) sobre as propriedades mecânicas e liberação de íons após imersão prolongada de compósitos experimentais / Effect of the addition of dicalcium phosphate dihidrate (DCPD) on mechanical properties and ion release after prolonged immersion of experimental composites

Maas, Mariel Soeiro 02 June 2017 (has links)
O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas diferenças estatisticamente significantes entre monômeros-base nos períodos de 1, 30 e 90 dias. O compósito contendo BisGMA apresentou liberações de fosfato estatisticamente maiores do que o material com BisEMA para todos os períodos de imersão, exceto após um dia. Após 60 dias a liberação de fósforo foi maior para ambos materiais em comparação aos 30 e 90 dias. Apenas para compósito contendo BisGMA foi verificada uma forte correlação linear entre liberação de cálcio e E (R2=0,990). Com base no exposto, pode-se concluir que: 1) o monômero-base utilizado afetou o GC dos materiais avaliados; 2) a presença de DCPD afetou a RFB inicial dos compósitos; 3) apenas os compósitos contendo BisGMA apresentaram reduções nas propriedades mecânicas após 90 dias; 4) ambos compósitos apresentaram diferenças nas concentrações finais de fosfato, mas não nas concentrações de cálcio liberadas; 5) houve correlação apenas entre liberação de cálcio e E de compósitos contendo BisGMA ao longo do período de imersão. Desta forma, todas as hipóteses nulas testadas devem ser rejeitadas. / The aim of the study was to evaluate the mechanical properties and ion release of experimental composites containing DCPD after different immersion periods. DCPD nanoparticles (10 vol%) were incorporated into equimolar mixtures of either BisGMA and TEGDMA or BisEMA and TEGDMA. Barium glass particles (50 vol%), 0,5% camphorquinone and 0,5% of ethyl 4-dimethylaminobenzoate were also added. Materials containing only barium glass particles (60 vol%) were considered as control groups. Degree of conversion (DC) was determined by near-FTIR (n=3). Biaxial flexural strength (BFS) and elastic modulus (E) were obtained through the biaxial flexural test. Fragments of the disk-shaped specimens tested in flexure were selected to perform the Knoop microhardness test (KHN). Specimens (n=10, 12x1mm) were tested after 1, 30, 60 and 90 days of immersion in NaCl solution (pH = 7.0). DC results were submitted to two-way ANOVA (\"monomer\" and \"presence of DCPD\"). KHN data were analyzed using three-way ANOVA (\"monomer\", \"presence of DCPD\" and \"immersion period\"). Multiple comparisons were made using Tukey test. BFS, E and ion release data were analyzed by Kruskal-Wallis/Dunn test (alpha = 5% in all cases). Regardless of the presence of DCPD, materials containing BisGMA presented statistically higher DC than materials containing BisEMA. Barium glass replacement by DCDP caused a reduction of the initial BFS for BisGMA and BisEMA composites and of initial E only for BisGMA. Materials containing BisGMA presented higher values of initial E and KHN. In general, composites containing BisGMA presented higher reductions in mechanical properties after 90 days. Thus, composites containing BisEMA presented higher final values of KHN (regardless of the presence of DCPD) and BFS (only for materials without DCPD). After 90 days, E and KHN values of materials with BisGMA were lower for the composite containing DCPD. Both composites showed increasing calcium release values during the 90 days, and no statistically significant differences were detected between composites with different monomers at 1, 30 and 90 days periods. BisGMA-containing composites showed a statistically higher phosphate release than the material with BisEMA in all immersion periods, except for one day period. After 60 days the phosphate release was higher for both materials when compared to 30 and 90 days period. Only for composite containing BisGMA a strong linear correlation between calcium release and E (R2 = 0.990) was verified. Based on the above, it can be concluded that: 1) the base-monomer affected the DC of the evaluated materials; 2) the presence of DCPD affected the initial BFS of the composites; 3) only BisGMA-containing composites showed reductions in mechanical properties after 90 days; 4) both composites showed differences in the final concentrations of phosphate, but not for the calcium concentrations; 5) there was a correlation only between calcium release and E of BisGMA-containing composites throughout the immersion period. Therefore, all null hypotheses tested were rejected.
3

Influência da adição de bioactive glass na liberação de íons do cimento de ionômero de vidro modificado por resina

Gwinner, Fernanda Pelógia Camargo [UNESP] 18 June 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-06-18Bitstream added on 2014-06-13T20:25:44Z : No. of bitstreams: 1 gwinner_fpc_dr_sjc.pdf: 429388 bytes, checksum: 8f66379f177aa22a57995cbad67ae92f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Esse estudo in vitro avaliou o efeito da adição de diferentes concentrações e composições de bioactive glass (BAG) ao cimento de ionômero de vidro modificado por resina (CIVMR) (Fuji II LC) na liberação de íons Ca2+ e PO4 3- após a imersão em simulador de fluido corpóreo (SFC), comparando com o grupo controle, sem BAG. Foram utilizados 3 tipos de BAG: BAG65 (65mol% SiO2, 31mol% CaO, 4mol% P2O5), BAG75 (75mol% SiO2, 21mol% CaO, 4mol% P2O5), BAG85 (85mol% SiO2, 11mol% CaO, 4mol% P2O5), adicionados ao CIVMR nas proporções de 25%, 35% e 50%. O BAG foi misturado ao pó do CIVMR e misturado com o líquido resinoso do CIVMR. O material foi colocado numa matriz de PVC (5mm x 1mm) e polimerizado, entre laminas de vidro, durante 40s. As amostras foram armazenadas a 37°C, com 100% de umidade, durante 24h. Após esse período as amostras foram trituradas por meio de gral e pistilo e peneiradas para a obtenção de partículas menores que 90μm. A liberação dos íons Ca2+ e PO4 3- foi mensurada após 15min, 30min, 1h, 3h, 6h e 24h de imersão de 20mg de cada material em SFC, com 5 réplicas para cada condição experimental. Para a análise estatística, foi utilizada a área sob a curva (PPM x tempo). Os dados foram submetidos à ANOVA e testes de Dunnet e Tukey (!= 0,05). Os grupos contendo BAG65 liberaram significantemente mais Ca2+ não havendo diferença entre as diferentes concentrações de BAG adicionado. Os grupos contendo BAG75 e BAG85 apresentaram resultados semelhantes, sendo que aqueles com 25% de BAG foram os que apresentaram menores valores de liberação de Ca2+ após 24h de imersão. Com relação a liberação de íons PO4 3-, os grupos contendo BAG65 apresentaram maiores valores de área... / Bioactive restorative materials may stimulate the repair of tooth structure though the release of remineralization-aiding components including calcium and phosphate. The objective of this study was to measure the ion release from resin-modified bioactive glass ionomer cement (RMBGIC) containing various formulations of bioactive glass (BAG). Three types of BAG: BAG65 (65 mol% SiO2, 31 mol% CaO, 4 mol% P2O5), BAG75 (75 mol% SiO2, 21 mol% CaO, 4 mol% P2O5), BAG85 (85 mol% SiO2, 11 mol% CaO, 4 mol% P2O5) were prepared using sol-gel method, grounded, micronized, and mixed with GIC powder (Fuji II LC, GC) in the following proportions: 1:1, 1:2, 1:3. The mixed-ionomer powders were combined with standard RMGIC liquid (Fuji II LC, GC) and light cured (40 s; Ultra Lume LED, 1100 mW/cm2) in cylindrical disk molds (5 mm x 2 mm). The cured RMBGIC specimens were grounded and sieved to 100 !m and immersed (20 mg; n=5) in 3 ml of simulated body fluid (SBF), at 37°C for 1/4, 1/2, 1, 3, 6 and 24 hours with continuous agitation. Following centrifugation and decanting, the [Ca+2] and [HxPO4 3-x] in the SBF were measured using ion specific electrode and visible spectroscopy, respectively. The amount of ion release were statistically analyzed using ANOVA/Tukey ($= 0.05). The [PO4 3-] in SBF immediately increased for all RMBGICs. The ion release slowly decreased after 1 h, yet remained higher than the original SBF over the 24 h period. The [PO4 3-] in SBF for the control GIC continuously decreased. Overall, BAG65 > BAG75= BAG85 > GIC for [PO4 3-]. The [Ca2+] release increase initially for all RMBGICs, remaining with higher values than thecontrol GIC. Resin modified glass ionomer cement... (Complete abstract click electronic access below)
4

Efeito da adição de fosfato dicálcico dihidratado (DCPD) sobre as propriedades mecânicas e liberação de íons após imersão prolongada de compósitos experimentais / Effect of the addition of dicalcium phosphate dihidrate (DCPD) on mechanical properties and ion release after prolonged immersion of experimental composites

Mariel Soeiro Maas 02 June 2017 (has links)
O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas O objetivo deste trabalho foi avaliar as propriedades mecânicas e a liberação de íons de compósitos experimentais contendo DCPD após diferentes períodos de imersão. Nanopartículas de DCPD (10 vol%) foram incorporadas em misturas equimolares de BisGMA e TEGDMA ou BisEMA e TEGDMA. Foram adicionadas também 50% de partículas de vidro de bário (VB), 0,5% de canforoquinona e 0,5% de amina terciária. Como controle, materiais contendo apenas partículas de VB (60%) foram avaliados. O grau de conversão (GC) foi determinado através de near-FTIR (n=3). Através do teste de flexão biaxial foram obtidos resultados de resistência à flexão biaxial (RFB) e módulo de elasticidade (E). Fragmentos dos discos testados em flexão foram selecionados para o teste de microdureza Knoop (KHN). Os espécimes (n=10, 12x01mm) foram fraturados após 1, 30, 60 e 90 dias imersos em solução de NaCl (pH=7,0). Os dados de GC foram submetidos ANOVA de dois fatores (\"monômero\" e \"presença de DCPD\"). Dados de KHN foram analisados através de ANOVA de três fatores (\"monômero\", \"presença de DCPD\" e \"tempo de imersão\"). Comparações múltiplas foram feitas utilizando-se o teste de Tukey. Dados de RFB, E e liberação de íons foram analisados através do teste de Kruskal-Wallis e as comparações múltiplas foram feitas pelo teste de Dunn (alfa=5% em todos os casos). Independentemente da presença de DCPD, materiais contendo BisGMA apresentaram GC estatisticamente maior do que materiais com BisEMA. A substituição de VB por DCDP provocou redução nos valores iniciais de RFB para BisGMA e BisEMA e em E apenas para BisGMA. Materiais com BisGMA apresentaram valores maiores de E e KHN iniciais. Em geral, compósitos com BisGMA apresentaram maiores reduções nas propriedades mecânicas ao final de 90 dias; assim, compósitos contendo BisEMA apresentaram valores finais mais altos de KHN (independente da presença de DCPD) e RFB (apenas para materiais sem DCPD). Após 90 dias, o E e KHN dos materiais com BisGMA foram menores no compósito com DCPD. Ambos compósitos apresentaram valores crescentes de liberação de cálcio ao longo dos 90 dias, não tendo sido detectadas diferenças estatisticamente significantes entre monômeros-base nos períodos de 1, 30 e 90 dias. O compósito contendo BisGMA apresentou liberações de fosfato estatisticamente maiores do que o material com BisEMA para todos os períodos de imersão, exceto após um dia. Após 60 dias a liberação de fósforo foi maior para ambos materiais em comparação aos 30 e 90 dias. Apenas para compósito contendo BisGMA foi verificada uma forte correlação linear entre liberação de cálcio e E (R2=0,990). Com base no exposto, pode-se concluir que: 1) o monômero-base utilizado afetou o GC dos materiais avaliados; 2) a presença de DCPD afetou a RFB inicial dos compósitos; 3) apenas os compósitos contendo BisGMA apresentaram reduções nas propriedades mecânicas após 90 dias; 4) ambos compósitos apresentaram diferenças nas concentrações finais de fosfato, mas não nas concentrações de cálcio liberadas; 5) houve correlação apenas entre liberação de cálcio e E de compósitos contendo BisGMA ao longo do período de imersão. Desta forma, todas as hipóteses nulas testadas devem ser rejeitadas. / The aim of the study was to evaluate the mechanical properties and ion release of experimental composites containing DCPD after different immersion periods. DCPD nanoparticles (10 vol%) were incorporated into equimolar mixtures of either BisGMA and TEGDMA or BisEMA and TEGDMA. Barium glass particles (50 vol%), 0,5% camphorquinone and 0,5% of ethyl 4-dimethylaminobenzoate were also added. Materials containing only barium glass particles (60 vol%) were considered as control groups. Degree of conversion (DC) was determined by near-FTIR (n=3). Biaxial flexural strength (BFS) and elastic modulus (E) were obtained through the biaxial flexural test. Fragments of the disk-shaped specimens tested in flexure were selected to perform the Knoop microhardness test (KHN). Specimens (n=10, 12x1mm) were tested after 1, 30, 60 and 90 days of immersion in NaCl solution (pH = 7.0). DC results were submitted to two-way ANOVA (\"monomer\" and \"presence of DCPD\"). KHN data were analyzed using three-way ANOVA (\"monomer\", \"presence of DCPD\" and \"immersion period\"). Multiple comparisons were made using Tukey test. BFS, E and ion release data were analyzed by Kruskal-Wallis/Dunn test (alpha = 5% in all cases). Regardless of the presence of DCPD, materials containing BisGMA presented statistically higher DC than materials containing BisEMA. Barium glass replacement by DCDP caused a reduction of the initial BFS for BisGMA and BisEMA composites and of initial E only for BisGMA. Materials containing BisGMA presented higher values of initial E and KHN. In general, composites containing BisGMA presented higher reductions in mechanical properties after 90 days. Thus, composites containing BisEMA presented higher final values of KHN (regardless of the presence of DCPD) and BFS (only for materials without DCPD). After 90 days, E and KHN values of materials with BisGMA were lower for the composite containing DCPD. Both composites showed increasing calcium release values during the 90 days, and no statistically significant differences were detected between composites with different monomers at 1, 30 and 90 days periods. BisGMA-containing composites showed a statistically higher phosphate release than the material with BisEMA in all immersion periods, except for one day period. After 60 days the phosphate release was higher for both materials when compared to 30 and 90 days period. Only for composite containing BisGMA a strong linear correlation between calcium release and E (R2 = 0.990) was verified. Based on the above, it can be concluded that: 1) the base-monomer affected the DC of the evaluated materials; 2) the presence of DCPD affected the initial BFS of the composites; 3) only BisGMA-containing composites showed reductions in mechanical properties after 90 days; 4) both composites showed differences in the final concentrations of phosphate, but not for the calcium concentrations; 5) there was a correlation only between calcium release and E of BisGMA-containing composites throughout the immersion period. Therefore, all null hypotheses tested were rejected.
5

Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activity

Aguilar, Fabiano Gamero 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.
6

Estudo da biocompatibilidade do cimento de aluminato de cálcio para uso odontológico, avaliação do pH, liberação de íons cálcio e atividade antimicrobiana / Biocompatibility of calcium aluminate cement for dental use, evaluation of pH, calcium ion release and antimicrobial activity

Fabiano Gamero Aguilar 20 April 2012 (has links)
O objetivo desse estudo foi avaliar o pH, a liberação de íons cálcio, a atividade antimicrobiana in vitro de cimento de aluminato de cálcio (EndoBinder) com diferentes radiopacificadores (óxido de bismuto, óxido de zinco e óxido de zircônia) e a biocompatibilidade do cimento acrescido de óxido de bismuto como agente radiopacificador, em comparação ao mineral trióxido agregado (MTA). Para a avaliação do pH e a liberação de íons cálcio, 25 amostras (n=5) de 2,0 x 10 mm foram obtidas de EndoBinder Puro (EBP), EndoBinder com Óxido de Bismuto (EBOB), EndoBinder com Óxido de Zinco (EBOZn), EndoBinder com Óxido de Zircônia (EBOZr) e Mineral Trióxido Agregado (MTA), que foram imersas em 10 ml água destilada e deionizada (pH=6,9). Após 2, 4, 12, 24, 48 horas, 7, 14 e 28 dias, foi medido o pH e a quantidade de íons cálcio da água onde as amostras foram imersas. Para a determinação in vitro da atividade antimicrobiana dos cimentos (EBP, EBOB, EBOZN, EBOZr e MTA), foram obtidas 15 amostras de cada material (n=3) de 5,0 x 5,0 mm colocadas em contato com 5 tipos de microrganismos: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) em placas de petri com Agar (Muller Hinton e Sabouraud Dextrose) deixadas em temperatura ambiente por 2 horas para a pré-difusão e depois incubadas a 37°C por 24 horas. Utilizou-se uma régua milimetrada com precisão de 0,5 mm para realizar as medidas dos halos de inibição em torno dos corpos de prova. A biocompatibilidade dos materiais foi avaliada a partir da implantação de tubos de polietileno em tecido subcutâneo de 15 ratos machos, sendo 1 implante escapular e 1 pélvico, num total de 2 tubos por animal (n=5). Como controle, foi utilizada a lateral do tubo de polietileno. Após 7, 21 e 42 dias os animais foram sacrificados e os tecidos processados para a obtenção dos cortes histológicos e posterior análise histopatológica. Os resultados do ensaio de pH, liberação de cálcio e de atividade microbiológica foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05). Os resultados de biocompatibilidade foram classificados quanto à severidade da reação inflamatória e quantificados em relação aos eventos presentes nas áreas pré-determinadas. Ao final de 28 dias não houve diferença estatística (p>0,05) entre nenhum grupo, tanto para o pH quanto para a liberação de íons cálcio. MTA, EBP e EBOB apresentaram atividade antimicrobiana quando em contato com todos os microrganismos, e EBOZr e EBOZn apenas quando em contato com Staphylococcus aureus e Candida glabrata. A reação inflamatória observada com os implantes subcultâneos diminuiu no decorrer do período de análise, porém ao final de 42 dias MTA ainda apresentou uma discreta reação inflamatória, situação não encontrada com o EB. Desta forma, concluiu-se que EB apresentou propriedades químicas e biológicas semelhantes ao MTA, além de apresentar menor reação tecidual, sendo biocompatível quando testado em tecido subcutâneo de ratos. / The purpose of this study was to evaluate the pH, calcium ion release, in vitro antimicrobial activity of a calcium aluminate cement (EndoBinder) with different radiopacifiers (bismuth oxide, zinc oxide, or zirconium oxide) and the biocompatibility of calcium aluminate cement with bismuth oxide radiopacifier in comparison with the mineral trioxide aggregate (MTA). For the evaluation of pH and calcium ion release 25 sample (n=5) measuring 2,0 x 10 mm were obtained from EndoBinder Pure (EBP), EndoBinder with bismuth oxide (EBOB), EndoBinder with zinc oxide (EBOZn), EndoBinder with zirconium oxide (EBOZr) and mineral trioxide aggregate (MTA) wich were immersed in a flask containing 10 ml of deionized and distilled water (pH=6,9). After 2, 4, 12, 24, 48 hours and 7, 14, 28 days, meassurements of the pH and calcium ion release from the water where the samples were immersed were assessed. To determine the in vitro antimicrobial activity of the cements (EBP, EBOB, EBOZN, EBOZr and MTA) 15 samples of each material (n=3) measuring 5,0 x 5,0 mm were placed in contact with five types of microorganisms: Escherichia coli (ATCC 25922), Enterococcus faecalis (ATCC 29212), Staphylococcus aureus (ATCC 25923), Candida albicans (ATCC 10231) e a Candida glabrata (ATCC 2001) .The MullerHinton agar (MH) diffusion method was employed and the plates were kept at room temperature for 2 hours for pre diffusion and then incubated at 37 C° for 24 hours. Zones of inhibition around the specimens were measured using a 0.5mm precision millimeter ruler. The biocompatibility of the test materials was evaluated from the implantation of 2 polyethylene tubes in the subcutaneous tissue of 15 male rats (n=5), 1 being scapular (EBOB) and 1 pelvic (MTA). The external tube wall was considered as the control group. After 7, 21 and 42 days animals were sacrificed, obtaining 5 tissue samples per group at each time interval of analysis then histological analysis was performed. The test results for pH, calcium ion release and in vitro antimicrobial activity were submitted to statistical analysis (two-way ANOVA, Bonferroni, p <0.05). The results of biocompatibility were classified according to severity of inflammatory reaction and quantified in relation to present events in pre-determined areas. After 28 days there was no statistical difference (p> 0.05) between any group for both the pH and calcium ions release. MTA, EBP and EBOB showed antimicrobial activity against all microorganisms and EBOZr and EBOZn only against Staphylococcus aureus and Candida glabrata. The inflammatory reaction observed with subcutaneous implants decreased during the period of analysis however, after 42 days MTA still had a discrete inflammatory reaction, this situation was not found with EBOB. Thus, it was concluded that EB has been shown to have similar biological and chemical properties compared with MTA, it also showed less tissue reaction and biocompatibility when tested in rat subcutaneous tissue.
7

Síntese e caracterização de partículas de fosfato de cálcio funcionalizadas com TEGDMA e sua aplicação no desenvolvimento de materiais resinosos remineralizadores / Synthesis and characterization of calcium phosphate particles functionalized with TEGDMA and their application in the development of remineralizing resin-based materials

Rodrigues, Marcela Charantola 24 October 2014 (has links)
Os objetivos deste trabalho foram : 1) sintetizar e caracterizar partículas de fosfato di-cálcico di-hidratado (DCPD) funcionalizadas com dimetacrilato de trietileno glicol (TEGDMA), com o propósito de reduzir a aglomeração e melhorar a interação entre as partículas e a matriz orgânica dos materiais resinosos e 2) avaliar o efeito da adição de partículas funcionalizadas em uma matriz resinosa em relação a liberação de íons, propriedades ópticas, grau de conversão, propriedades mecânicas e microestrutura do material. Na primeira etapa do trabalho foram sintetizadas pelo método sol-gel dois tipos partículas de DCPD: funcionalizadas e puras. Além dessas, caracterizou-se nesta etapa partículas comerciais do mesmo composto. As partículas foram caracterizadas por difração de raio X (DRX), espectroscopia no infravermelho com transformada de Fourier (FTIR), análise elementar, análise termogravimétrica (TGA), isortermas de adsorção de nitrogênio e método BET, microscopia eletrônica de transmissão e espalhamento de luz dinâmico (DLS). Na segunda etapa do trabalho, um novo lote de partículas funcionalizadas foi sintetizado, e como controle, sintetizou-se partículas não funcionalizadas. Quatro materiais resinosos foram formulados, um deles contendo apenas BisGMA e TEGDMA (1:1 em mols) e os demais contendo, além da matriz resinosa, 20% (em volume) de partículas funcionalizadas, partículas não funcionalizadas ou sílica coloidal silanizada. Os materiais foram avaliados quanto à liberação de íons, propriedades ópticas (transmitância total e E em relação à resina sem carga), grau de conversão (GC), resistência à flexão biaxial (RFB), módulo de elasticidade e análise microestrutural. Os dados foram submetidos à análise de variância (ANOVA), complementada pelo teste de Tukey, com nível de significância de 5 %. A composição das partículas foi confirmada por DRX e a funcionalização das mesmas foi confirmada pelas análises de FTIR, análise elementar e TGA. As partículas funcionalizadas apresentaram área superficial até 3 vezes maior quando comparadas às partículas puras e comerciais. Esses dados foram confirmados pela análise de DLS, que encontrou aglomerados maiores para as partículas dos compostos puro e comercial. Na segunda etapa do estudo, observou-se que a funcionalização das partículas não afetou a liberação de íons Ca2+ dos materiais bioativos; entretanto, a liberação de íons HPO42- foi 51% menor para o material contendo partículas funcionalizadas. Todos os materiais apresentaram GC semelhantes. O compósito com sílica apresentou valores de transmitância significantemente menores e E superior ao obtido para os demais materiais. A funcionalização das partículas aumentou a RFB em 32%, porém ainda inferior à do compósito com sílica. A funcionalização não afetou o módulo de elasticidade dos materiais. A síntese de partículas de DCPD funcionalizadas com TEGDMA foi realizada com êxito. O monômero funcionalizante contribuiu para a diminuição do tamanho dos aglomerados. Além disso, a funcionalização favoreceu a interação entre as partículas de DCPD e a matriz orgânica dos materiais, evidenciado pelo aumento no valor de resistência à flexão, sem redução substancial na liberação de íons cálcio do material. / The aims of this study were: 1) to synthesize and characterize dicalcium phosphate dihidrate (DCPD) particles functionalized with triethylene glycol dimethacrylate (TEGDMA), with the purpose of reducing agglomeration and improve the interaction between the particles and the organic matrix of resin-based materials and 2) evaluate the effect of the addition of functionalized particles in a resin matrix regarding ion release, optical properties, degree of conversion, mechanical properties and microstructure. In the first part of the study, two types of DCPD particles were synthesized by a sol-gel method: functionalized and bare. Additionally, proprietary DCPD particles were also characterized. Particles were characterized by X-ray diffraction (DRX), Fourier-transformed infrared spectroscopy (FTIR), elemental analysis, thermogravimetric analysis (TGA), Nitrogen adsorption isotherms and BET method, transmission electron microscopy and dynamic light scattering (DLS). In the second part, a new batch was synthesized and, as a control, non-functionalized nanoparticles were synthesized. Four resin-based materials were prepared, one containing only BisGMA and TEGDMA (1:1 in mols) and the other containing besides the resin, 20 % (in volume) of functionalized, non-functionalized or silanized colloidal silica particles. Materials were evaluated for ion release, optical properties (total transmittance and E, in relation to the unfilled resin), degree of conversion (DC), biaxial flexural strength (BFS), elastic modulus and microstructural analysis. Data were subjected to analysis of variance (ANOVA), complemented by Tukey test, with a global significance level of 5%. Particles composition was confirmed by DRX, while functionalization was confirmed by FTIR , elemental analysis and TGA. Functionalized particles presented surface area up to three times higher compared to bare and proprietary particles. These findings were confirmed by DLS, which found larger agglomerates for the bare and proprietary particles. In the second part of the study, it was observed that particle functionalization did not affect Ca2+ release from the bioactive materials; however, HPO42- release was 51% lower from the material containing functionalized particles. All materials presented similar DC. The silica composite presented transmittance values significantly lower and higher E than the other materials. Functionalization increased BFS in 32%, however, it remained lower than the silica-containing composite. Functionalization did not affect elastic modulus. The synthesis of functionalized particles was accomplished with success. The functionalized monomer contributed for reducing agglomerate size. Also, functionalization favored the interaction between DCPD particles and the resin matrix of the materials, evidenced by the increase in flexural strength, without substantially reducing calcium release from the material.
8

Síntese e caracterização de partículas de fosfato de cálcio funcionalizadas com TEGDMA e sua aplicação no desenvolvimento de materiais resinosos remineralizadores / Synthesis and characterization of calcium phosphate particles functionalized with TEGDMA and their application in the development of remineralizing resin-based materials

Marcela Charantola Rodrigues 24 October 2014 (has links)
Os objetivos deste trabalho foram : 1) sintetizar e caracterizar partículas de fosfato di-cálcico di-hidratado (DCPD) funcionalizadas com dimetacrilato de trietileno glicol (TEGDMA), com o propósito de reduzir a aglomeração e melhorar a interação entre as partículas e a matriz orgânica dos materiais resinosos e 2) avaliar o efeito da adição de partículas funcionalizadas em uma matriz resinosa em relação a liberação de íons, propriedades ópticas, grau de conversão, propriedades mecânicas e microestrutura do material. Na primeira etapa do trabalho foram sintetizadas pelo método sol-gel dois tipos partículas de DCPD: funcionalizadas e puras. Além dessas, caracterizou-se nesta etapa partículas comerciais do mesmo composto. As partículas foram caracterizadas por difração de raio X (DRX), espectroscopia no infravermelho com transformada de Fourier (FTIR), análise elementar, análise termogravimétrica (TGA), isortermas de adsorção de nitrogênio e método BET, microscopia eletrônica de transmissão e espalhamento de luz dinâmico (DLS). Na segunda etapa do trabalho, um novo lote de partículas funcionalizadas foi sintetizado, e como controle, sintetizou-se partículas não funcionalizadas. Quatro materiais resinosos foram formulados, um deles contendo apenas BisGMA e TEGDMA (1:1 em mols) e os demais contendo, além da matriz resinosa, 20% (em volume) de partículas funcionalizadas, partículas não funcionalizadas ou sílica coloidal silanizada. Os materiais foram avaliados quanto à liberação de íons, propriedades ópticas (transmitância total e E em relação à resina sem carga), grau de conversão (GC), resistência à flexão biaxial (RFB), módulo de elasticidade e análise microestrutural. Os dados foram submetidos à análise de variância (ANOVA), complementada pelo teste de Tukey, com nível de significância de 5 %. A composição das partículas foi confirmada por DRX e a funcionalização das mesmas foi confirmada pelas análises de FTIR, análise elementar e TGA. As partículas funcionalizadas apresentaram área superficial até 3 vezes maior quando comparadas às partículas puras e comerciais. Esses dados foram confirmados pela análise de DLS, que encontrou aglomerados maiores para as partículas dos compostos puro e comercial. Na segunda etapa do estudo, observou-se que a funcionalização das partículas não afetou a liberação de íons Ca2+ dos materiais bioativos; entretanto, a liberação de íons HPO42- foi 51% menor para o material contendo partículas funcionalizadas. Todos os materiais apresentaram GC semelhantes. O compósito com sílica apresentou valores de transmitância significantemente menores e E superior ao obtido para os demais materiais. A funcionalização das partículas aumentou a RFB em 32%, porém ainda inferior à do compósito com sílica. A funcionalização não afetou o módulo de elasticidade dos materiais. A síntese de partículas de DCPD funcionalizadas com TEGDMA foi realizada com êxito. O monômero funcionalizante contribuiu para a diminuição do tamanho dos aglomerados. Além disso, a funcionalização favoreceu a interação entre as partículas de DCPD e a matriz orgânica dos materiais, evidenciado pelo aumento no valor de resistência à flexão, sem redução substancial na liberação de íons cálcio do material. / The aims of this study were: 1) to synthesize and characterize dicalcium phosphate dihidrate (DCPD) particles functionalized with triethylene glycol dimethacrylate (TEGDMA), with the purpose of reducing agglomeration and improve the interaction between the particles and the organic matrix of resin-based materials and 2) evaluate the effect of the addition of functionalized particles in a resin matrix regarding ion release, optical properties, degree of conversion, mechanical properties and microstructure. In the first part of the study, two types of DCPD particles were synthesized by a sol-gel method: functionalized and bare. Additionally, proprietary DCPD particles were also characterized. Particles were characterized by X-ray diffraction (DRX), Fourier-transformed infrared spectroscopy (FTIR), elemental analysis, thermogravimetric analysis (TGA), Nitrogen adsorption isotherms and BET method, transmission electron microscopy and dynamic light scattering (DLS). In the second part, a new batch was synthesized and, as a control, non-functionalized nanoparticles were synthesized. Four resin-based materials were prepared, one containing only BisGMA and TEGDMA (1:1 in mols) and the other containing besides the resin, 20 % (in volume) of functionalized, non-functionalized or silanized colloidal silica particles. Materials were evaluated for ion release, optical properties (total transmittance and E, in relation to the unfilled resin), degree of conversion (DC), biaxial flexural strength (BFS), elastic modulus and microstructural analysis. Data were subjected to analysis of variance (ANOVA), complemented by Tukey test, with a global significance level of 5%. Particles composition was confirmed by DRX, while functionalization was confirmed by FTIR , elemental analysis and TGA. Functionalized particles presented surface area up to three times higher compared to bare and proprietary particles. These findings were confirmed by DLS, which found larger agglomerates for the bare and proprietary particles. In the second part of the study, it was observed that particle functionalization did not affect Ca2+ release from the bioactive materials; however, HPO42- release was 51% lower from the material containing functionalized particles. All materials presented similar DC. The silica composite presented transmittance values significantly lower and higher E than the other materials. Functionalization increased BFS in 32%, however, it remained lower than the silica-containing composite. Functionalization did not affect elastic modulus. The synthesis of functionalized particles was accomplished with success. The functionalized monomer contributed for reducing agglomerate size. Also, functionalization favored the interaction between DCPD particles and the resin matrix of the materials, evidenced by the increase in flexural strength, without substantially reducing calcium release from the material.
9

Avaliação da radiopacidade, escoamento, pH e da liberação de íons cálcio de um cimento endodôntico biocerâmico / Evaluation of Radiopacity, flow, pH and release of calcium ions of a bioceramic root canal sealer

Candeiro, George Taccio de Miranda 02 October 2012 (has links)
O objetivo do presente trabalho foi avaliar as propriedades físico-químicas de um cimento endodôntico biocerâmico, Endosequence BC Sealer (Brasseler USA, Savannah, GA, EUA). Radiopacidade, escoamento, pH e liberação de íons cálcio (Ca2+) foram analisadas e os resultados foram comparados aos do cimento AH Plus (Dentsply De Trey Gmbh, Konstanz, Alemanha). A radiopacidade e o escoamento foram avaliados de acordo com as normas ISO 6876/2001. Para o teste de radiopacidade, anéis metálicos com 10 mm de diâmetro e 1 mm de altura foram preenchidos com os cimentos. O valor da radiopacidade foi determinado de acordo com a densidade radiográfica, representada em mm Al. A análise do escoamento foi feita com 0,05 mL de cada cimento colocados sobre uma placa de vidro. Outra placa de vidro, com 20 g, foi cuidadosamente colocada sobre o cimento e sobre esta um peso de 100 g, totalizando 120 g, que permaneceram por 7 minutos. Em seguida, foram medidos os diâmetros maiores e menores dos discos formados, sendo esta feita com um paquímetro digital. A liberação de íons cálcio (Ca2+) e o pH foram medidos nos períodos de 3, 24, 72, 168 e 240 horas, com o auxílio de um espectrofotômetro e pHmetro, respectivamente. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, sendo considerado significante quando p<0,05. O cimento biocerâmico analisado apresentou radiopacidade (3,84 mm Al) significantemente menor do que o AH Plus (6,90 mm Al). Foi observado que o cimentos Endosequence BC Sealer e o AH Plus apresentaram escoamentos de 26,96 mm e 21,17 mm, respectivamente (p<0,05). O cimento biocerâmico apresentou maior pH e maior liberação de íons cálcio (Ca2+) do que o cimento AH Plus (p<0,05). Concluiu-se que o cimento Endosequence BC Sealer apresentou valores de radiopacidade e de escoamento em concordância com as norma ISO 6876/2001. Os valores de pH e de liberação de íons cálcio (Ca2+) foram favoráveis para um cimento endodôntico. / The aim of the present study was to evaluate the physicochemical properties of a bioceramic root canal sealer, Endosequence BC Sealer. Radiopacity, pH, release of calcium ions (Ca2+) and flow were analyzed and the results were compared with AH Plus cement. Radiopacity and flow were evaluated according to ISO 6876/2001 standards. For the radiopacity analysis, metallic rings with 10 mm in diameter and 1 mm of thickness were filled with cements. The radiopacity value was determined according to radiographic density (mm Al). The flow test was performed with 0.05 mL of cement placed on a glass plate. A 120-g weight was carefully placed over the cement. The largest and smallest diameters of the disks formed were measured using a digital caliper. The release of Ca2+ and pH were measured at periods of 3, 24, 72, 168 and 240 hours, with spectrophotometer and pHmeter, respectively. Data were analyzed by ANOVA and Tukeys test (p<0.05). The bioceramic endodontic cement showed radiopacity (3.84 mm Al) significantly lower than that of AH Plus (6.90 mm Al). The pH analysis showed that Endosequence BC Sealer showed pH and release of Ca2+ greater than those of AH Plus (p<0.05), during the experimental periods. The flow test revealed that the BC Sealer and AH Plus presented flow 26.96 mm and 21.17 mm, respectively (p<0.05). Endosequence BC Sealer showed radiopacity and flow according to ISO 6876/2001 recommendations. The others physicochemical properties analyzed demonstrated favorable values for a root canal sealer.
10

Efeito das pastilhas higienizadoras efervescentes à base de peróxido alcalino em liga metálica de cobalto-cromo / Effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys

Vasconcelos, Glenda Lara Lopes 17 December 2015 (has links)
A higienização das próteses é de fundamental importância para a longevidade do tratamento reabilitador. Entretanto, é necessário analisar os efeitos que os higienizadores podem causar nas superfícies que compõem uma prótese. Deste modo, o objetivo deste estudo foi avaliar os efeitos de pastilhas efervescentes à base de peróxido alcalino em liga de cobalto cromo (Co-Cr), utilizada em Prótese Parcial Removível (PPR). A partir de uma matriz metálica, padrões de cera em forma de disco (12 mm x 3 mm) foram confeccionados para posterior fundição. Os espécimes metálicos (n=16) foram imersos nas soluções: água deionizada (controle), Polident 3 minutes®, Steradent®, Efferdent®, Polident for Partials® e Corega Tabs®. Foi realizada a análise da rugosidade (n=10) por meio de rugosímetro, antes (t0) e após 5 períodos de simulação de ½, 1, 2, 3, 4 e 5 anos de imersão nos higienizadores. Foram realizadas análises complementares quantitativas da liberação de íons (n=5) de cobalto (Co), cromo (Cr) e molibdênio (Mo) em cada solução e análises qualitativas em um espécime de cada grupo, por meio de Microscopia Eletrônica de Varredura (MEV) e Espectrometria de Energia Dispersiva de Raios X (EDS). A distribuição dos dados de rugosidade (&mu;m) apresentou-se não normal. Foi utilizada estatística não-paramétrica (&alpha;=0,05). Tanto para o fator solução (Kruskall Wallis, ½ ano (p=0,900), 1 ano (p=0,277), 2 anos (p=0,227), 3 anos (p=0,086), 4 anos (p=0,657) e 5 anos (p=0,856), como para o fator tempo (Friedman, p=0,137) não houve diferença significante. Com relação à liberação de íons (&mu;g/L), a distribuição dos dados apresentou-se normal. De acordo com a estatística (&alpha;=0,05, ANOVA e teste de Tukey), Corega Tabs®, Efferdent® e água deionizada promoveram maior liberação de íons Co do que o Steradent® (p=0,003). Quanto aos íons Cr (p=0,000), Corega Tabs® propiciou maior liberação quando comparado a água deionizada, Steradent® e Polident 3 minutes®. Em relação aos íons Mo (p=0,001), o Efferdent® promoveu maior liberação. No MEV pode-se verificar que as soluções não apresentaram efeitos deletérios sobre as superfícies. Conclui-se que todas as pastilhas avaliadas não ocasionaram danos, entretanto, Steradent® foi a que propiciou menor liberação de íons, sendo indicada com maior segurança para higienização de superfícies metálicas de PPR. / The hygiene care of the removable dentures is of most importance for the longevity of the rehabilitation treatment. However, it is necessary to analyze the effects that denture cleansers can cause on the surfaces of prosthesis. Thus, the aim of this study was to evaluate the effect of alkaline peroxide-effervescent tablets on the surfaces of the cobalt-chromium alloys (Co-Cr), used in removable partial dentures (RPD). Circular specimens (12 mm x 3 mm) were fabricated with cobalt-chromium alloys. The specimens (n= 16) were immersed in the following solutions: deionized water (control), Polident 3 minutes&trade;, Steradent&trade;, Efferdent&trade;, Polident for Partials&trade; and Corega Tabs&trade;. The surface roughness (n=10) was analyzed with a surf-test analyzer, before and after 5 periods that corresponds to the simulation of ½, 1, 2, 3, 4 and 5 years of immersion in the cleansers. As complementary analysis, it was performed a quantitative study of ions release (n=5) for cobalt (Co), chromium (Cr) and molybdenum (Mo) in each solution and qualitative analysis with scanning electron microscopy (SEM) associated to Energy-dispersive X-ray spectroscopy (EDS). The results of surface roughness had presented no normal. In nonparametric statistics (&alpha; = 0.05), both of the solution factor Kruskall Wallis, ½ year (p=0.900), 1 year (p=0.277), 2 years (p=0.227), 3 years (p=0.086), 4 years (p=0.657) and 5 years (p=0.856), such as time factor (Friedman, p = 0.137), there was no significant difference. The results of ionic release presented a normal distribution and they were submitted to ANOVA (p=0.05) and Tukey test. The solutions Corega Tabs®, Efferdent® and deionized water presented greater Co ionic release than Steradent® (p=0.003). For Cr ions (p=0.000), Corega Tabs® had greater ionic release than deionized water, Steradent® and Polident 3 minutes®. Regarding Mo ions (p=0.001), Efferdent® showed greater release. With SEM, it was possible to verify that the solutions showed no deleterious effects on the specimen surfaces. It was concluded that no deleterious effects on metal surface was caused, however, Steradent® presented the smallest ionic release, and can be indicated more safely for cleaning metal surfaces of RPD.

Page generated in 0.4372 seconds