• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 53
  • 52
  • 8
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 122
  • 122
  • 39
  • 37
  • 32
  • 19
  • 16
  • 15
  • 15
  • 14
  • 13
  • 13
  • 13
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Properties of investments for porcelain inlays a thesis submitted in partial fulfillment ... /

Aguirre M., Marco Antonio. January 1965 (has links)
Thesis (M.S.)--University of Michigan, 1965.
62

A comparison of translucency in dental porcelains relative to human enamel a thesis submitted in partial fulfillment ... in restorative dentistry ... /

Brodbelt, Robert H. W. January 1977 (has links)
Thesis (M.S.)--University of Michigan, 1977.
63

Análise rugosimétrica de duas cerâmicas odontológicas submetidas a diferentes tratamentos de superfície

Ticianeli, Márcio Giampá [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1 ticianeli_mg_me_arafo.pdf: 1350387 bytes, checksum: ea0f36454c6c9f5c29da9a1476668be1 (MD5) / Este estudo avaliou a eficiência de diferentes técnicas de acabamento e polimento sobre duas cerâmicas odontológicas (Duceram Plus e Duceram LFC), em relação à rugosidade média superficial (Ra). Foram preparados quarenta discos com 8 mm de diâmetro e 4 mm de espessura para cada uma das cerâmicas utilizadas, seguindo-se as recomendações do fabricante. Previamente ao glazeamento, todos os corpos-de-prova foram regularizados com o auxílio de lixas d'água de diferentes granulações (240,360 e 600, nesta ordem), recebendo, em seguida, uma camada de glaze. Os 40 corpos-de-prova de cada cerâmica foram divididos em 8 grupos com 5 representantes em cada um, recebendo diferentes tratamentos de superfície: T1- glaze; T2- desgaste com ponta diamantada fina e ultrafina; T3- T2 + sistema de acabamento e polimento dental Sof-Lex (3 M); T4- T3 + pasta diamantada; T5- T2 + kit de polimento Super-Snap (Shofu); T6- T5 + pasta diamantada; T7- T2 mais borrachas abrasivas Viking (KG Sorensen); T8- T7 + pasta diamantada. Foram realizadas cinco mensurações de rugosidade média (Ra, em æm) em cada corpo-de-prova, utilizando-se um rugosímetro ajustado com cut-off de 0,25 mm, extensão de tracejamento de 1,25 mm e velocidade de medição de 0,10 mm/s. Os resultados foram analisados estatisticamente pelos testes ANOVA e Tukey, com nível de significância de 5%. Os melhores tratamentos para ambas as cerâmicas avaliadas foram T3, T4, T5 e T6, apresentando semelhança estatística entre si; O glazeamento (T1) foi similar estatisticamente aos tratamentos T3, T4, T5 e T6 para a cerâmica Duceram LFC, em relação ao fator Ra; O tratamento T1 apresentou-se com diferença estatisticamente significante e mais rugoso que o tratamento T3, T4 e T6 para a cerâmica Duceram Plus, em relação ao fator Ra; As duas cerâmicas odontológicas avaliadas apresentaram... / This study assessed the efficacy of different current porcelain finishing and polishing procedures on two different dental ceramic (Duceram Plus and Duceram LFC) quantitatively with a profilometer. Forty disks (8 mm in diameter and 4 mm thick) were prepared for each dental ceramic according to the manufacturer's directions. Prior to glazing, all specimens' surfaces were abraded using a 240, 360 and 600-grit wet sandpaper. Then, all samples were glazed. The forty samples of each dental ceramic were divided into 8 groups of five specimens each, according to the surface treatment: T1- glaze; T2- abraded with fine and ultra fine diamond burs (KG Sorensen); T3- T2 following Sof-Lex (3M) polishing system; T4- T3 following diamond paste; T5- T2 following Super-Snap polishing kit (Shofu); T6- T5 following diamond paste; T7- Viking rubber wheels (KG Sorensen); T8- T7 following diamond paste. Five roughness measurements (Ra, æm) were performed on each disc using a profilometer with cut-off value of 0.25 mm and a tracing length of 1.25 mm and a speed of 0.1 mm per second. These values were tested using a two-way analysis of variance and Tukey test at 5% significance level. The result showed (to Ra factor) that T3, T4, T5 and T6 were the best surface treatment for both dental ceramic materials and were statistically equals; the glazed treatment (T1) was similar statistically to the polishing treatment T3, T4, T5 and T6 for Duceram LFC ceramic; the glazed treatment (T1) was different statistically and rougher than the polishing treatment T3, T4 e T6 for Duceram Plus ceramic; the two different dental ceramic had similar behavior when received the same surface treatment; and the diamond-abraded group (T2) had the rougher surface in both dental ceramic studied.
64

Influência do método de processamento na resistência à flexão, tração diametral e dureza dos sistemas cerâmicos

Oliva, Eduardo Andrade de [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-27Bitstream added on 2014-06-13T20:37:52Z : No. of bitstreams: 1 oliva_ea_me_arafo.pdf: 736376 bytes, checksum: 9f17d42680a151e51a9530e89dcbeb9a (MD5) / O objetivo deste trabalho foi avaliar a resistência à flexão, a resistência à tração diametral e a dureza das cerâmicas feldspáticas AllCeram (processada por sinterização) e Cergogold (processada por injeção à vácuo) e Ceramco 2 (processada por sinterização convencional e por injeção). Foram confeccionadas dez amostras de cada grupo experimental para o ensaio de resistência à flexão (em forma de barra, 25mm de comprimento, 5mm de largura, 2mm de espessura - ISO 6872) e 15 amostras para o ensaio de resistência à tração diametral (em forma de disco, 6mm de diâmetro, 3mm de espessura). Os testes foram realizados em equipamento MTS 810 (Material Test System, EUA), com célula de carga de 10kN e velocidade de 0,5mm/minuto, gerenciado por programa Test Star II (IBM, EUA). Para o ensaio de dureza, na escala Vickers, cinco fragmentos de cada grupo foram incluídos em resina acrílica autopolimerizável, polidos e submetidos ao teste no durômetro Buheler (EUA), com carga de 1,0kgf por 30 segundos. Dento da técnica de processamento indicada pelo fabricante, nos ensaios de resistência à flexão e dureza, os resultados apontaram igualdade estatística entre os materiais Ceramco 2 (73,75MPa / 478,8VNH) e Cergogold (68,96MPa / 495,3VHN); a seguir, com valores estatisticamente inferiores está a cerâmica All-Ceram (50,51MPa / 451VHN). No ensaio de resistência à tração diametral, houve igualdade estatística entre os 3 materiais: Ceramco 2 (34,15MPa), Cergogold (33,95MPa) e AllCeram (29,74MPa). Para a cerâmica Ceramco 2, o método de processamento sinterização ou injeção à vácuo não interferiu na resistência mecânica, apresentando valores com igualdade estatística para as três propriedades estudadas: respectivamente, resistência à flexão (73,75MPA, 77,88MPa), resistência à tração diametral (34,15MPa, 33,52MPa) e dureza... / The aim of this study was to compare flexural strength, diametral tensile strength and hardness of ceramics AllCeram (convencional fusing), Cergogold (heat-pressed) and Ceramco 2 (convencional fusing and heat-pressed). Ten especimens were made for flexural test (25mm length; 5mm width; 2mm thick - ISO 6872), and 15 especimens for diametral test (6mm diameter, 3mm thick). The tests were done in a MTS 810 machine (Material Test System - USA), with load cell of 10kN and crosshead-speed of 0.5mm/minute, managed by Test Star II software (IBM, USA). Five samples of each ceramic were included in autocured resin JET (Artigos odontológicos Clássico, Brazil), polished and submitted to Vickers hardness test in duromer Buheler (USA), with load of 1.0kgf for 30 seconds. Manuffacturer' processing technique the mean flexural stengths and hardness was significantly similar for Ceramco 2(73,75MPa / 478,8VNH) and Cergogold (68,96MPa / 495,3VNH), and significantly stronger than AllCeram (50,51 / 451VNH). All materials did not differ for diametral tensile (AllCeram 29,74MPa; Cergogold, 33,95MPa; Ceramco 2, 34,15MPa). Effects of processing method (convencional fusing and heat-pressed) did not influenced on flexural strength (73,75MPa / 77,88MPa), diametral tensile strength (34.15 MPa / 33,52 MPa) and hardness (478,8VHN / 471,5VHN) of Ceramco 2. However, for Ceramco 2 (heat-pressed) flexural strength (77,88MPa) became significantly higher and hardness (471,5VHN) became significantly lower than Cergogold (68,96MPa, 495,3VHN).
65

Influencia da soldagem laser e ciclos de cocção da porcelana no desajuste marginal de infra-estruturas de proteses fixas em titanio comercialmente puro e titanio-aluminio-vanadio fundidos pelas tecnicas convencional e sobre-modelo refratario / Influence of the laser-welding and ceramic firing cycle over the desadaptation frameworkd margins of commercially pure titanium and titanium-aluminum-vanadium alloy with the conventional casting and refractory die

Correa, Giovani de Oliveira 07 May 2003 (has links)
Orientador: Lourenço Correr Sobrinho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T19:03:33Z (GMT). No. of bitstreams: 1 Correa_GiovanideOliveira_D.pdf: 622152 bytes, checksum: a395604ad381cd7abfdc99e9110c1421 (MD5) Previous issue date: 2005 / Resumo: A soldagem é uma alternativa para a obtenção de melhor ajuste marginal de retentores metálicos de próteses fixas de três ou mais elementos aos respectivos pilares, em detrimento da fundição tipo monobloco (peça única). No entanto, há a possibilidade de defeitos nas uniões soldadas ou distorções de todo o conjunto. Embora a adaptação não esteja assegurada, as fundições tipo monobloco são vantajosas quanto à economia de tempo, resistência e durabilidade da infra-estrutura. O propósito desse estudo foi a avaliar a soldagem laser na redução do desajuste marginal de infra-estruturas fundidas em titânio comercialmente puro e titânio-alumínio-vanádio; os efeitos do ciclo de cocção da porcelana no desajuste marginal em infra-estruturas de próteses fixas fundidas em monoblocos sobre-modelo refratário, comparando os resultados com a técnica convencional de fundição de próteses fixas. Inicialmente confeccionou-se uma matriz metálica, sendo esta moldada em silicona por adição para a obtenção dos modelos de trabalho. Sobre os modelos foram encerados os padrões simulando infra-estruturas de próteses fixas, correspondendo às fundições convencionais nas duas ligas avaliadas. Para a fundição sobre-modelo, a matriz metálica foi duplicada e modelos em revestimento Rematitan Plus foram obtidos. Sobre os modelos de revestimento foram encerados os padrões simulando as infra-estruturas protéticas, sendo o conjunto padrões/modelo refratário, incluído para a realização das fundições. As infra-estruturas fundidas foram jateadas com óxido de alumínio, ajustadas internamente e acabadas por fresas. Os desajustes marginais foram medidos em microscópio mensurador (Olympus - Japão) com aumento de 50 X. Após a aplicação dos respectivos tratamentos, as infra-estruturas foram submetidas à simulação dos ciclos de cocção (bonder; opaco; corpo e; glaze). As mensurações foram realizadas após todas as fases do estudo, os dados foram tabulados e submetidos a Análise de variância com parcela subdividida e ao teste de Tukey em nível de 5% de significância. Concluiu-se que: a soldagem a laser foi eficaz na redução dos desajustes nas infra-estruturas em ambas as ligas; a etapa bonder interferiu no desajuste nas infra-estruturas / Abstract: Soldering has been an alternative for achieving acceptable marginal fit of metallic crowns of 3-unit fixed frameworks to the respective abutments, in detriment of the single-piece casting. However, defects at the joined areas or distortions of the entire frame are frequent. Although adaptation can not be assured, single-piece casting presents advantages such as time saving, strength and strength of the framework. The purpose of this study was to evaluate: the laser-welding in the decrease of unfitted frameworks margins of commercially pure titanium and titanium-aluminum-vanadium alloy; the effects of the ceramic firing cycle over the unfitted frameworks margins using the method of single-piece casting using a refractory die, comparing the results with the conventional casting technique for fixed prosthodontics. Initially a metallic cast was prepared and duplicated using addition silicone for making working casts. For the conventional technique, the 3-unit simulated frameworks were waxed over the working casts. For the single-piece casting, the metallic cast was duplicated and investment dies were made (Rematitan Plus ¿ c.p. Ti and Ti-6Al-4V). The frameworks were waxed on the investment casts that were invested for the castings. After casting, the frameworks were air-abraded with aluminum oxide particles, adjusted and finished with the aid of wheels. The marginal fit was measured under a measurer microscope (Olympus ¿ Japan) with X50 magnification. After laser welding, frameworks were submitted to firing cycle (bonder, opaque, dentin and glaze). The marginal fit was measured after the studies¿ steps. ANOVA and Tukey¿s tests were used in the statistical analysis of the results (P<0.05). It was concluded that the laser-welding was effective in the decrease of marginal unfit of the frameworks on both alloys; the bonder application did not interfere on the marginal fit of the frameworks / Doutorado / Doutor em Materiais Dentários
66

Influência do tratamento ácido em infraestruturas de ligas metálicas de cobalto-cromo, sobre a resistência da união metalocerâmica / Influence of acid treatment on infrastructures of cobalt-chromium dental alloy, on metal ceramic bond strength

Sobreiro, Michelli Menezes 12 January 2018 (has links)
O objetivo desse trabalho foi verificar a influência do tratamento ácido realizado em superfície metálica de cobalto-cromo sobre a resistência de união metalocerâmica (RUMC), que é um dos critérios fundamentais para o sucesso da restauração protética. A partir de uma matriz de teflon, foram confeccionadas 120 tiras em resina acrílica Duralay (25 mm x 3,0 mm x 0,5 mm), que foram em três grupos experimentais, de acordo com a liga de cobalto-cromo (Keragen, Remanium 2001 e StarLoy C) utilizada na fundição. Em seguida, as tiras metálicas obtidas foram usinadas e jateadas com óxido de alumínio 100 µm. e subdivididas em quatro grupos (n=10), de acordo com o tratamento de superfície realizado, totalizando 12 grupos experimentais. Para o grupo controle (C), nenhum tratamento adicional foi realizado. O grupo T1 foi tratado adicionalmente com ácido clorídrico a 37% (HCl 37%) por 10 minutos, T2 com HCl 37% por 20 minutos e T3 com HCl 37% por 30 minutos. Após a realização do tratamento, os espécimes foram imersos em álcool isopropílico, limpos em ultrassom e secos em temperatura ambiente. Na sequência foi aplicada a cerâmica (IPS inline), composta por duas camadas de opaco e duas de dentina. Os espécimes foram submetidos ao teste de flexão de três pontos, em máquina de ensaios mecânicos para obtenção dos valores de carga de ruptura (MPa). Dada a distribuição normal dos dados, foi realizada análise estatística por meio da Análise de Variância de dois fatores, seguida pelo teste de Bonferroni (=0,05). Entre as ligas metálicas, não houve diferença significante (p=0,088). Entre os tratamentos (p=0,023) o grupo T3 (61,57 ± 12,19) apresentou valores estatisticamente maiores que o grupo controle (51,96 ± 13,54). Não houve diferenças entre os grupos T1 (57,82 ± 13,22) e T2 (57,91 ± 10,08). Também não houve interação entre a liga metálica e o tratamento de superfície realizado (p= 0,106). Dessa forma, pode-se concluir que o tratamento da superfície metálica com ácido clorídrico a 37% por 30 minutos favoreceu a união da cerâmica às ligas de Co-Cr / The aim of this study was to assess the influence of the acid treatment performed on the metallic surface of cobalt-chromium on metal ceramic bond strength (MCBS), which is one of the fundamental criteria for prosthetic restorations success. One-hundred and twenty strips of Duralay acrylic resin (25 mm x 3.0 mm x 0.5 mm) were made from a Teflon matrix, which were cast into three different cobaltchromium alloys (Keragen, Remanium 2001 and StarLoy C) and subdivided into four groups (n = 10), according to the surface treatment performed. Afterwards, the metal strips obtained were machined and sandblasted with 100 m aluminum oxide. For control group (C), no additional treatment was performed. The T1 group was further treated with 37% hydrochloric acid (37% HCl) for 10 minutes, T2 with 37% HCl for 20 minutes and T3 with 37% HCl for 30 minutes. After the acid treatment, specimens were immersed in isopropyl alcohol, cleaned in ultrasound and dried at room temperature. Posteriorly, ceramic (IPS inline) was applied, composed of two layers of opaque and two layers of dentin. Specimens were submitted to three-point bending test in a mechanical test machine to obtain rupture loading values (MPa). The results were analyzed using 2-way ANOVA (=0.05) and Bonferroni post-hoc test. Among dental alloys, there was no significant difference (p=0.088). Among treatments (p=0.023), T3 group (61.57 ± 12.19) had values statistically higher than control group (51.96 ± 13.54). There were no differences between T1 (57.82 ± 13.22) and T2 (57.91 ± 10.08) groups. There was also no interaction between dental alloy and the surface treatment performed (p=0.106). In conclusion, metal surface treatment with 37% hydrochloric acid for 30 minutes favored bonding between ceramic and Co-Cr alloys
67

\"Estudo espectrofotométrico comparativo da estabilidade de cor de três porcelanas dentais após consecutivas queimas\" / Comparative spectrophotometric study of the color stability of three dental porcelains after repeated firings

Weber, Marcelo 25 September 2006 (has links)
O objetivo deste estudo foi avaliar a estabilidade de cor de três marcas comerciais de porcelanas aluminizadas durante seu processo de queima. Para o experimento foram confeccionados 30 corpos de prova em forma de disco com 2mm de espessura e 10mm de circunferência, sendo 10 da marca ALLCeram, 10 da marca Noritake Cerabien CZR e 10 da marca Vita VM7. As amostras foram queimadas 10 vezes. As leituras de cor foram feitas em espectrofotômetro de reflexão nos seguintes intervalos: após a 1ª queima, após a 3ª queima, após a 5ª queima e após a 10ª queima. As curvas de reflexão foram convertidas em valores LAB e a diferença de cor foi medida através do método CIELAB (FE). Os resultados obtidos demonstraram que existe variação de cor e que esta variação depende do número de queimas realizadas e da marca comercial utilizada. / The purpose of this investigation was to quantify in CIE FE units the differences in color produced by multiple firing of three allceramic systems. For this study 30 samples were fabricated of 3 brands: AllCeram, Noritake Cerabien CZR and Vita VM7. A spectrophotometer was used for reflectance measurement of color after 1 firing, 3 firings, 5 firings and 10 firings. The results were converted in CIELAB units. Color differences, FE, were calculated in the CIE color space. Color differences as a result of multiple firings depended on the number of firings and the brand tested.
68

A avaliação da confiabilidade e modo de falha de coroas de sistemas cerâmicos em função do desenho da infraestrutura e da aplicação de carga em cristas marginais / Evaluation of reliability and failure modes of ceramic crown systems depending on framework design and marginal ridge load application

Fardin, Vinícius Pavesi 29 May 2013 (has links)
As excelentes propriedades mecânicas da zircônia fazem com que ela seja o material cerâmico de eleição para as coroas e próteses fixas posteriores. Porém, os problemas relacionados à fratura ainda persistem. A falta de suporte das infraestruturas às cerâmicas de revestimento é indicada como uma possível causa. O presente estudo visou avaliar através de testes laboratoriais se as infraestruturas metálicas e cerâmicas com o desenho convencional ou modificado apresentam diferença estatisticamente significante quanto à redução de complicações mecânicas, como fraturas e trincas na cerâmica de revestimento ao receberem cargas axiais nas cristas marginais de coroas de um primeiro molar inferior, por meio das seguintes hipóteses nulas: 1) a resposta à fadiga nas cristas marginais não aumentará a presença de danos nas coroas; 2) o desenho da I.E. não modificará a presença de danos nas coroas, independente do material utilizado. Quarenta coroas unitárias foram confeccionadas sobre preparos padronizados e divididos em 4 grupos: grupo I (infraestrutura convencional de Cobalto-Cromo); grupo II (infraestrutura modificada de Cobalto-Cromo); grupo III (infraestrutura convencional de Zircônia - IPS Emax ZirCAD); grupo IV (infraestrutura modificada de Zircônia - IPS Emax ZirCAD). Estas coroas foram submetidas ao teste de resistência à fadiga por meio da ciclagem dinâmica em água (106 ciclos ou até a fratura com carga variando de 30-300 N). Aplicou-se a carga inicial com o endentador cerâmico de dissilicato de lítio (IPS Emax Press) na crista marginal mesial, e após o término do ciclo, na distal, alternativamente. A ciclagem foi interrompida em intervalos de 125 mil ciclos a procura de danos com auxílio de estereomicroscopia. Ao final, as coroas fraturadas foram submetidas à microscopia eletrônica de varredura e as não fraturadas foram incluídas em resina epóxi e polidas sequencialmente para a análise dos danos. Cada corpo de prova recebeu escores de acordo com o tipo de falha apresentado. Utilizou-se o teste Kruskal-Wallis para verificar diferença estatística entre os grupos e o teste de Dunn para comparações múltiplas entre os grupos. Os resultados mostraram que há diferença estatisticamente significante entre os grupos, entretanto não houve diferença entre os grupos do mesmo sistema cerâmico. Concluiu-se que a hipótese 1 foi aceita e a 2 rejeitada. / The excellent mechanical properties of zirconia make it to be the material of choice for ceramic crowns and posterior fixed prostheses. However, problems still exist related to the chippings. The lack of framework support to ceramic veneer is indicated as a possible cause. This study aimed to evaluate through laboratory tests if metallic and ceramic framework with conventional or modified design show statistical difference in reducing mechanical complications, such as chipping or fracture of the ceramic veneer on receiving axial loads in marginal ridges of the first molar inferior crowns through the following null hypotheses: 1) the response to fatigue in marginal ridges will not increase the presence of damage to the crowns; 2) framework`s design will not modify the presence of damage to the crowns, regardless of the material used. Forty crowns were manufactured on standardized preparations and divided into four groups: group I (conventional framework Cobalt-Chromium), group II (modified framework Cobalt-chromium), group III (conventional framework Zirconia - ZirCAD IPS Emax) and group IV (modified framework Zirconia - IPS Emax ZirCAD). These crowns were subjected to cyclic loading in a fatigue machine and submerged in water (1.000.000 cycles or until the fracture - load range at 30-300 N). The initial load was applied on the mesial marginal ridge with indenter ceramic Lithium disilicate (IPS Emax Press), and after the end of the cycle, the distal alternatively. The cycling was interrupted at a prescribed number of loading cycles (125.000) and crowns were inspected for damage accumulation under a stereomicroscope. In the end, fractured crowns were submitted to scanning electron microscopy and crowns without fractures were embedded in epoxy resin and sequentially polished for the analysis of the damage. Each sample received scores according to the type of failure presented. Statistical analysis was carried out with Kruskal-Wallis test and multiple conparisons between groups were carried out with Dunn wed significant differences between groups, however there was no difference between the groups of the same ceramic systems. It was concluded that the first hypothesis was accepted and the second hypothesis was rejected.
69

Efeito da pigmentação extrínseca nas cerâmicas à base de dissilicato de lítio submetidas aos processos de desgaste e biodegradação nas propriedades mecânicas e aderência bacteriana /

Barcellos, Aline Serrado de Pinho. January 2019 (has links)
Orientador: Lafayette Nogueira Junior / Coorientador: Estevão Tomomitsu Kimpara / Banca: Tarcísio José de Arruda Paes Junior / Banca: João Maurício Ferraz da Silva / Banca: Fabíola Pessôa Pereira Leite / Banca: Júlio César Brigolini de Faria / Resumo: O objetivo deste estudo foi avaliar se há alteração no comportamento mecânico e na aderência microbiológica da cerâmica à base de dissilicato de lítio com a técnica de pigmentação extrínseca aplicada, após ser submetida a diferentes condições experimentais. Foram confeccionadas 160 amostras, divididas em grupos com e sem pigmentação (n=80). Destes, cada grupo foi subdividido em Controle, Desgate, Biodegradação e Desgaste com Biodegradação (n=20).15 amostras de cada subgrupo foram submetidas ao teste de resistência à flexão e 5 para o teste de aderência microbiológica. As amostras passaram anteriormente por testes complementares para caracterização da superfície (rugosidade, perfilometria volumétrica e microscopia eletrônica de varredura (MEV)). Os resultados foram submetidos a análise estatística descritiva (média e desvio padrão) e inferencial, mediante o teste paramétrico de análise de variância (ANOVA) dois fatores e teste de Tukey ( = 0,05). O fator pigmentação extrínseca influenciou negativamente no comportamento mecânico da cerâmica, apresentando significância estatística (p = 0,000), assim como a interação entre o tipo de condição experimental e a pigmentação (p = 0,020). Entretanto, na aderência microbiológica, foi a condição experimental que influenciou negativamente no comportamento microbiológico (p = 0,000), assim como a interação entre a condição experimental e a pigmentação (p = 0,000). Nas análises complementares, observou-se que a interação entre os fatores a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The objective of this study was to evaluate the mechanical and microbiological behavior of the ceramics based on lithium disilicate with extrinsic characterization. For this, 160 discs were made, divided into two large groups, with extrinsec characterization and without, after which each was divided into four groups (n = 20): Control, Wear, Biodegradation and Biodegradation with Wear. Fifteen samples from each group were submitted to the flexural strength test and 5 submitted to the microbiological adherence test. Prior to the destructive test of flexural strength, the representative samples of each group underwent complementary tests for surface characterization. The results were submitted to descriptive statistical analysis (mean and standard deviation) and inferential, using the parametric analysis of variance (ANOVA) two way and Tukey test ( = 0,05). The extrinsec characterization factor influenced the mechanical behavior of the ceramic, presenting statistical significance (p = 0.000), as well as the interaction between the type of experimental condition and the extrinsec characterization (p = 0.020). However, in the microbiological adherence, it was the experimental condition that influenced the microbiological behavior (p = 0.000), as well as the interaction between the experimental condition and the extrinsec characterization (p = 0.000). It was concluded that the makeup influenced the mechanical behavior of the ceramic, and the experimental condition influenced the m... (Complete abstract click electronic access below) / Doutor
70

Tratamento de superfície de porcelanas dentárias pela irradiação com laser de CO2 / Surface treatment of dental porcelains with CO2 laser

Sgura, Ricardo 04 July 2013 (has links)
Este estudo teve como objetivo testar o laser de CO2 como um agente de tratamento de superfície de porcelanas dentárias. Material e Métodos: O estudo foi dividido em duas etapas: na primeira etapa, discos de porcelana (3,5 mm diam. x 2,0 mm espess.) das marcas VM7, VM9 e VM13 (VITA) foram sinterizados e tiveram uma de suas faces asperizadas por uma ponta diamantada 2134F para acabamento. Os espécimes foram então divididos em grupos de acordo com os seguintes tratamentos: nenhum (C), auto-glaze em forno (G) e irradiação com laser (L) de CO2 (Coherent, = 10,6 m, 35 W) de forma contínua com 40, 45 ou 50 W/cm2 nos tempos de 3, 4 ou 5 minutos (n=7). Nesta primeira etapa, as caracterizações das amostras constaram de: difratometria por raios-X, diferença de cor (Easyshade VITA), rugosidade superficial (Surftest 301, Mitutoyo) e análise visual por meio de esteromicroscopia e MEV. Um espécime de VM9 de cada grupo foi polido e levado a um exame por microscopia de força atômica (MFA). A segunda etapa consistiu na sinterização de discos das três porcelanas nas mesmas dimensões da etapa anterior, porém submetidos a um polimento de uma das superfícies com soluções diamantadas de granulação decrescente até 1 m. Os grupos testados foram os mesmos da primeira etapa, com exceção dos grupos irradiados com 40W/cm2. As caracterizações que se seguiram foram (n=10): microdureza Vickers, tenacidade à fratura, porosidade superficial, razão de contraste (RC) e capacidade de mascaramento (CM). Resultados: A rugosidade de espécimes asperizados foi diminuída pela aplicação do laser nas irradiâncias de 45 e 50 W/cm2, similar ao auto-glaze em forno, sem alteração de cor perceptível para a quase totalidade dos grupos irradiados. Houve um aumento do conteúdo cristalino das porcelanas VM9 e VM13 após a irradiação com o laser. As micrografias (MEV) demonstraram padrão de superfície homogêneo para os espécimes dos grupos irradiados a 50 W/cm2 e G. Os resultados da segunda etapa apontaram para alterações na microdureza e tenacidade à fratura na dependência da marca comercial e das irradiâncias estudadas. Quanto à porosidade, as porcelanas VM7 e VM13 apresentaram um aumento na fração volumétrica de poros, enquanto a porcelana VM9 irradiada apresentou-se semelhante a G. As médias de RC e CM indicaram um aumento na opacidade das porcelanas VM7 e VM13 irradiadas com o laser. Conclusão: Em condições específicas, o laser de CO2 é capaz de produzir uma lisura de superfície semelhante ao auto-glaze, com pequenas alterações nos aspectos ópticos e mecânicos. As diferentes marcas comerciais de porcelana apresentaram comportamentos distintos em relação aos tratamentos aplicados. / Glazing porcelain is an important procedure in dentistry that leads to surface smoothness, to less plaque accumulation and to brightness, especially after a chair side adjustment. Despite a good absorption of CO2 laser wavelength by dental porcelain it has not yet been tested as an alternative to oven glaze. Aim: This study tested CO2 laser as a heat source in surface treatment of dental porcelains. Material and Methods: This study was divided in two stages: at the first stage porcelain discs (VM7, VM9, VM13 VITA; 3.5 diam. x 2.0 mm thickness) were sintered, machined and had one of their sides grounded by a diamond bur (2134F KG Sorensen) simulating a chair side adjustment in clinical office. Specimens were then divided into groups according to treatment: no treatment (C); auto-glazed in conventional furnace (G) and submitted to CO2 continuous laser irradiation (Coherent, = 10.6 m; output power = 35 W, 0.5 cm laser beam) in 40, 45 or 50 W/cm2 for 3, 4 or 5 minutes (n=7). Specimens were supported by a ceramic refractory. At this first stage, the characterization consisted of X-ray diffraction (RU-200B, Rigaku), color difference (E) (Easyshade VITA), roughness (Surftest 301, Mitutoyo) and analysis of images achieved by stereomicroscopy (SZ61, Olympus) and SEM (Stereoscan 440, LEO). A VM9 specimen of each group had one of their side polished and was submitted to atomic force microscopy (AFM) Nanoscope IIIA (Veeco). In the second stage discs with the same dimension described above were sintered and polished with diamond solutions (Ecomet 3; 1 m). The same groups were tested except 40W/cm2 irradiance. Specimens were submitted to the following characterizations (n=10): Vickers microhardness test, fracture toughness by indentation fracture (HMV, Shimadzu), surface porosity (HMV, Image J software), contrast ratio (CR) and masking ability (MA) (CM-3770d, Konica Minolta). Results from both stages were submitted to one-way-ANOVA or Kruskall-Wallis test. A post-hoc Tukey test was applied when necessary ( = 0.05). Results: Ground specimens showed a reduction in roughness after laser irradiation (45 and 50 W/cm2), comparable to oven-glazed specimens with almost no color change. SEM images presented similarity between a irradiated group (50W/cm2) and G. AFM test revealed the formation of long rounded peaks and long valleys after laser exposition. Second stage results pointed to changes in microhardness and fracture toughness of irradiated specimens depending on the porcelain and irradiance tested. Regarding porosity, after laser exposition, porcelain VM7 and VM13 presented an increase in pores (area fraction) for the majority of groups while VM9 porcelain didnt show any increase in porosity after laser incidence. CR and MA means pointed to an increase in porcelain opacity to irradiated specimens of VM7 and VM13. Conclusion: Under specific conditions CO2 laser was able to produce a surface smoothness similar to auto-glaze, despite punctual changes in some optical and mechanical properties. The different brands presented distinct effects after laser heat treatment.

Page generated in 0.2766 seconds