• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 151
  • 79
  • 8
  • 7
  • 7
  • 7
  • 7
  • 7
  • 2
  • 1
  • Tagged with
  • 245
  • 245
  • 145
  • 106
  • 62
  • 59
  • 33
  • 32
  • 28
  • 28
  • 28
  • 25
  • 24
  • 24
  • 23
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
91

Efeito do laser Nd:Yag no pré-tratamento dentinário e selamento marginal, em restaurações de cimento de ionômero de vidro resina modificado /

Lima, Dimas Renó de. January 2003 (has links)
Orientador: Rosehelene Marotta Araújo / Banca: José Eduardo Pelizon Pelino / Banca: Margareth Oda / Banca: Silvio Issáo Myaki / Banca: Suely Carvalho Mutti Naressi / Resumo: 0 objetivo deste estudo foi avaliar o selamento marginal de restaurações com cimento de ionômero de vidro resina modificado ap6s aplicação do laser Nd:YAG sabre o primer, fotopolimerizado ou não, e nas margens da restauração empregando-se o teste de microinfiltração. Foram realizadas 120 restaurações classe V nas superfícies vestibular e lingual de cada dente, divididas em seis grupos onde foram observados os efeitos do laser Nd:YAG sabre a dentina e nas margens das restaurações. Os corpos de prova foram tenmociclados em temperaturas de 5°C a 55°C, podendo variar de ± 2°C, e imersos em uma solução de nitrato de prata a 50%. Realizou-se um corte no centro da restauração no sentido vestíbulo lingual para determinar o grau de micro infiltração nas margens oclusal e gengival de cada corpo de prova. Foram empregados os métodos estatísticos Kruskal-Wallis não paramétricos e o teste de sinais de pastas de Wilcoxon com nível de significância de 5%. A metodologia empregada para avaliar a infiltração marginal permitiu concluir que: todos os grupos apresentaram resultados semelhantes de micro infiltração para a margem oclusal e gengival não diferindo estatisticamente entre si; quando comparamos as graus de micro infiltração entre a margem oclusal e gengival observamos que os grupos II e III não apresentaram diferenças estatisticamente significantes, enquanto que os grupos I, IV, V e VI apresentaram diferenças estatisticamente significantes; comparando a margem oclusal com a gengival observamos uma menor infiltração na margem gengival / Abstract: The purpose of this study was to evaluate the marginal sealing of resin modified glass ionomer cement restorations after the application of the Nd:YAG laser on the primer, light cured or not, and on the margins of the restoration using the micro leakage test. 120 class V restorations on the vestibular and lingual surfaces of each tooth were performed, divided into six groups in which the effects of the Nd:YAG laser on the denun and on the margins of the restoration were obseved. The specimens were thermocycled at 5°C and 55°C, ± 2°C, and immersed in 50% silver nitrate solution. A cut in the center of the restoration in the vestibular lingual direction to determine the degree of microleakage in the occlusal and gingival margins of each specimen was performed. The statistical methods Kruskal-Wallis, non-parametric, and the Wilcoxon's Paired Signed Rank Test were used at 5% significance level. The methodology used to evaluate the marginal leakage made it possible to conclude that: all groups presented similar micro leakage results for the occlusal and gingival margins and were not statistically different between them; when the degrees of micro leakage were compared between the occlusal and gingival margins it was observed that groups II and Ill did not present significant statistical difference, while groups I, IV, V and VI presented significant statistical differences; when the occlusal margin was compared to the gingival, a smaller gingival marginal leakage was observed / Doutor
92

Physicochemical and biological properties of Biodentine associated with radiopacifiers /

Ochoa Rodríguez, Victor Manuel January 2018 (has links)
Orientador: Gisele Faria / Resumo: BiodentineTM (BD) apresenta bioatividade, biocompatibilidade e propriedades físico-químicas adequadas; no entanto, não possui radiopacidade adequada. Os objetivos foram avaliar (1) a radiopacidade de BD e BD associado com 15% de tungstato de cálcio (BDCaWO4) ou óxido de zircônio (BDZrO2), empregando sistemas de radiografia convencional e digital; e (2) as propriedades físico-químicas de tempo de presa, pH e solubilidade, e as propriedades biológicas de citocompatibilidade e potencial para induzir mineralização desses cimentos. Para a avaliação da radiopacidade, cada corpo de prova foi radiografado ao lado de uma escada de alumínio usando filme oclusal, placa de fósforo ou sensores digitais. As radiografias convencionais foram digitalizadas por câmera fotográfica ou scanner. Os valores médios de cinza dos materiais foram expressos em milímetros de alumínio (mm Al). A solubilidade foi avaliada após 7 dias de imersão dos espécimes em água destilada e expressa em percentagem de perda de massa. O tempo de presa foi avaliado empregando a agulha de Gillmore (105 ± 0,5 g) e o pH foi mensurado com um medidor de pH. A citocompatibilidade e a bioatividade celular foram avaliadas em células de linhagem osteoblástica (Saos-2) utilizando os ensaios de metiltetrazólio (MTT), vermelho neutro (NR), atividade de fosfatase alcalina (ALP) e coloração de vermelho de alizarina. Os dados foram avaliados utilizando ANOVA de um fator e pós-teste Tukey ou ANOVA de dois fatores e pós-teste de Bonferron... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: BiodentineTM (BD) presents bioactivity, biocompatibility and suitable physicochemical properties; however, it does not have adequate radiopacity. The objectives were to evaluate (1) the radiopacity of BD and BD associated with 15% calcium tungstate (BDCaWO4) or zirconium oxide (BDZrO2), employing conventional and digital radiography systems; and (2) the physicochemical properties of setting time, pH and solubility, and biological properties of cytocompatibility and potential to induce mineralization of these cements. For radiopacity evaluation, each cement specimen was radiographed alongside an aluminum step-wedge using occlusal film, photostimulable phosphor plates or digital sensors. The conventional radiographies were digitized by digital photographic camera or scanner. Mean grey values of materials were expressed in millimeters of aluminum (mm Al). Solubility was evaluated after 7 days of specimens’ immersion in distilled water and expressed as percentage of mass loss. Setting time was evaluated employing a Gillmore needle (105 ± 0.5 g) and pH was evaluated with pH meter. The cytocompatibility and cell bioactivity were evaluated in osteoblasts-like cells (Saos-2) using methyl-thiazol-tetrazolium (MTT), neutral red (NR), alkaline phosphatase (ALP) activity and alizarin red staining assays. The data were evaluated using one-way ANOVA and Tukey post-test or two-way ANOVA and Bonferroni post-test (α=0.05). BD radiopacity was below 3 mm Al and BDZrO2 and BDCaWO4 was above 3 mm... (Complete abstract click electronic access below) / Mestre
93

Análise da interface adesiva entre cimentos resinosos e diferentes terços da dentina intrarradicular

Suzuki, Thaís Yumi Umeda [UNESP] 18 October 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-10-18Bitstream added on 2014-06-13T19:16:55Z : No. of bitstreams: 1 suzuki_tyu_me_araca.pdf: 994382 bytes, checksum: 75c8c1831c920cfd4ce4e1f797803c6c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O propósito deste estudo foi avaliar as técnicas de cimentação adesiva de pinos de fibra de vidro nos diferentes terços da dentina intrarradicular, através da resistência de união e avaliação de propriedades mecânicas da interface adesiva. Quarenta dentes humanos unirradiculares foram utilizados neste estudo. Após obturação endodôntica e preparo mecânico dos condutos radiculares, os dentes foram divididos em cinco grupos experimentais (n=8), de acordo com a técnica adesiva adotada para cimentação de pinos de fibra de vidro: Grupo 1: adesivo fotoativado Single Bond 2 + cimento resinoso RelyX ARC; Grupo 2: adesivo dual Excite DSC + RelyX ARC; Grupo 3: adesivo autocondicionante Adper SE Plus + RelyX ARC; Grupo 4: cimento resinoso autoadesivo RelyX Unicem; Grupo 5: cimento resinoso autoadesivo Set. As propriedades mecânicas de dureza e módulo de elasticidade foram mensuradas nas estruturas da interface adesiva em ultramicrodurômetro digital DUH-211. A resistência de união foi mensurada pelo teste de push-out em máquina de ensaio universal nos diferentes terços da dentina intrarradicular (cervical, médio e apical). Os dados de resistência de união e propriedades mecânicas foram submetidos a testes estatísticos de normalidade e analisados pela ANOVA e teste de Fisher ( = 0,05). Os resultados mostraram que as propriedades mecânicas de dureza Martens e módulo de elasticidade dos materiais adesivos e do substrato dentinário são influenciados pela interação dos materiais resinosos utilizados, bem como pela profundidade intrarradicular. O mesmo fenômeno foi observado no teste de resistência de união. Para os materiais resinosos, houve uma tendência de o terço apical apresentar os menores valores das propriedades analisadas, o que poderia conduzir à realização de preparos intrarradiculares mais conservativos / The purpose of this study was to evaluate techniques for adhesive cementation of glass fiber posts in different thirds of intra-root dentin, through the bond strength and evaluation of mechanical properties of the adhesive interface components. Forty extracted single-rooted human teeth were used in this study. After endodontic filling and mechanical preparation of root canal, teeth were divided into five groups (n=8), according to the technique adopted for adhesive cementation of glass fiber posts: Group 1: Single Bond 2 light-cured adhesive + RelyX ARC resin cement; Group 2: Excite DSC dual adhesive + RelyX ARC; Group 3: Adper SE Plus self-etch adhesive + RelyX ARC; Group 4: RelyX Unicem self-adhesive resin cement; Group 5: Set selfadhesive resin cement. The mechanical properties of Martens hardness and elastic modulus were measured in the structures of the adhesive interface in a DUH-211 digital ultramicro hardness tester (Shimadzu). Push-out bond strength was measured in a universal testing machine (Emic DL 3000) in different areas of intra-root dentin (cervical, middle and apical). The data of bond strength and mechanical properties were subjected to statistical tests of normality and analyzed by ANOVA and Fisher’s test ( =0.05). The results showed that the mechanical properties of Martens hardness and elastic modulus of the adhesive materials and dentin substrate can be influenced by the interaction of the materials, as well as the depth of intraradicular dentin. The same phenomenon was observed in the push-out bonding strength test. There was a tendency of the apical region show the least values of mechanical properties, which could stimulate the use of more conservative intraradicular preparation
94

Avaliação de três cimentos resinosos na resistência de união entre dentina e uma cerâmica de zircônia estabilizada por ítria

Castro, Humberto Lago de [UNESP] 01 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-01Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 castro_hl_me_sjc.pdf: 1527108 bytes, checksum: e3b403c8e46c094fafb49bdc789f3c3b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Objetivou-se avaliar a resistência à tração (σ) da união de três sistemas de cimentação resinosa de ativação dual (RelyX ARC, RelyX U100 e Panavia F) entre a dentina e uma cerâmica à base de zircônia estabilizada por óxido de ítrio (In-Ceram YZ, Vita Zanhfabrik) com diferentes tratamentos de superfície. A superfície oclusal de 54 terceiros molares humanos hígidos foi exposta e condicionada conforme as instruções de cada cimento. Cinqüenta e quatro blocos cerâmicos foram planificados e sinterizados (6,4 mm x 6,4 mm x 4,8 mm). Após, foram divididos em dois grupos conforme o tipo de tratamento de superfície: jateamento com óxido de alumínio ≤ 50 μm ou silicatização (CoJet, 3M ESPE)(24-28 psi). A cimentação à dentina foi realizada de acordo com as instruções de cada fabricante. Assim, foram constituídos 6 grupos. Os conjuntos foram armazenados em água destilada à 37°C por 24 h e cortados no sentido x e y, 9 corpos de prova (cp) por conjunto foram obtidos em média (área adesiva de ± 1 mm2). Os cp de cada conjunto foram divididos aleatoriamente em 3 condições de armazenagem: ensaio imediato; 60 dias de armazenagem em água destilada (37ºC) e termociclagem (10.000x, 5ºC - 55ºC) (n≥12). O ensaio de resistência adesiva por microtração foi realizado numa máquina de ensaio universal (1 mm/min). Nos grupos imediatos RelyX ARC-silicatização e Panavia Fjateamento apresentaram as médias mais altas de σ (13,9 e 13,0 MPa, respectivamente), seguido do RelyX U100-jateamento (10,2 MPa). Após a termociclagem, o cimento Panavia F-jateamento foi melhor (14,8 MPa) seguido pelo RelyX ARC-silicatização e RelyX U100-jateamento (12,9 e 9,9 MPa, respectivamente). Após a armazenagem por 60 dias, os cimentos se comportaram de forma semelhante, onde os grupos que foram silicatizados demonstraram uma tendência a valores mais elevados de σ (MPa) / The aim of this study was to evaluate the bond strength of three dualcured resin cement systems (RelyX ARC, RelyX U100 and Panavia F) to dentin and to an yttria-stabilized zirconia-based ceramic (In-Ceram YZ, Vita Zanhfabrik) after different surface treatments. The occlusal surface of 54 sound human third molars was exposed and conditioned according to the manufacturers’ instructions. Fifty-four ceramic blocks were cut (6.4mm x 6.4mm x 4.8mm), flattened and fired. They were divided into two groups according to the type of surface treatment: air-abrasion with ≤ 50μm alumina particles or CoJet system (3M ESPE) (14-28 psi). The cementation procedure followed the instructions of each manufacturer. Thus, there were 6 groups. All teeth-cement-ceramic blocks were stored in 37°C distilled water for 24 hours before cutting into non-trimming specimens (adhesive area= 1 mm²). About nine specimens (sp) were obtained per block (n=27). The specimens of each block were randomly assigned to one of the three storage conditions: dry- immediate test, W60- 60 days of storage (37°C water) and TC- thermocycling (10,000x) (n≥12). The microtensile bond strength test was performed using an universal testing machine (crosshead speed: 1 mm/min). Immediate groups of RelyX ARC-Cojet and Panavia F-air-abrasion presented the highest σ average (13.9 and 13.0 MPa, respectively), followed by RelyX U100-airabrasion (10,2 MPa). After TC, Panavia F-air-abrasion was the best (14.8 MPa) followed by RelyX ARC-Cojet and RelyX U100-air-abrasion (12.9 and 9.9 MPa, repectively). After W60, all the cements behaved similarly, when the groups were treated with Cojet system, tended to higher values of σ (MPa)
95

Avaliação da resposta tecidual e capacidade de mineralização de cimentos que contém compostos biocerâmicos, resinosos e com hidróxido de cálcio /

Bueno, Carlos Roberto Emerenciano. January 2015 (has links)
Orientador: Eloi Dezan Junior / Banca: Luciano Tavares Ângelo Cintra / Banca: Marco Antonio Húngaro Duarte / Resumo: A obturação ideal é uma combinação de um cimento com um material sólido, geralmente guta percha, que corrobora com o escoamento do cimento fluido, espalhando-o e preenchendo possíveis espaços vazios. Em virtude da possibilidade de contato direto com os tecidos periapicais, estes cimentos devem ser biocompatíveis e, se possível, estimular a mineralização para proporcionar selamento apical. Com o objetivo de avaliar, in vivo, a resposta tecidual e a capacidade de mineralização dos cimentos endodônticos Smartpaste® Bio, Sealapex® e Acroseal®, foi realizado implante subcutâneo em 40 ratos Wistar e adotados os períodos experimentais de 7, 15, 30 e 60 dias (10 animais por período de tempo). Cada animal recebeu quatro implantes, três tubos de polietileno com os cimentos a serem testados e um tubo vazio como controle. Após cada período pós-operatório, os animais foram eutanasiados e os tubos de polietileno, juntamente com o tecido circunjacente foram removidos e fixados. Para a análise histológica da espessura da cápsula fibrosa, infiltrado inflamatório e mineralização as peças foram incluídas em historresina, e coradas em HE, Von Kossa ou permaneceram sem coloração para a luz polarizada. Os resultados foram submetidos ao teste de Kruskal Wallis e Dunn (p<0,05). Resultados: Todos os cimentos produziram reação inflamatória moderada nos períodos iniciais. O Smartpaste Bio® apresentou a menor reação inflamatória aos 15 dias (p<0,05). O Sealapex® induziu maior mineralização, seguido do Smartpaste Bio®. O Acroseal® não apresentou indução de mineralização. Conclusão: Ao final do experimento, todos os cimentos testados apresentaram compatibilidade tecidual. Com exceção do Acroseal, todos induziram mineralização. / Abstract: The cleaning and shaping of root canals is essential to achieve biological and mechanical goals in the endodontic treatment, providing the appropriate conical shape for subsequent obturation. The optimal obturation is a combination of a sealer with a central core, usually gutta percha, spreading and filling possible gaps. Once there is a direct contact with periapical tissue, the sealer should be biocompatible and, if possible, stimulate mineralization to perform an apical sealing. In order to evaluate in vivo biological response and tissue mineralization capacity of the endodontic sealers Smartpaste Bio® Sealapex® and Acroseal®, subcutaneous implants in 40 Wistar rats were performed. Analisys were at 7, 15, 30 and 60 days experimental periods (10 animals for each time period). Each animal received four implants, three polyethylene tubes with the sealers in test and one empty tube as control. After each post-operative period animals were euthanized and the polyethylene tubes, along with surrounding tissue were removed and fixed. In order to histologically analysis fibrous capsule thickness, inflammatory infiltrate and mineralization, the pieces were included in historesin and stained in HE, Von Kossa or remained without staining for observation under polarized light. The results were statistically analyzed by Kruskal-Wallis and Dunn (p<0,05). Results: All sealers promoted moderate inflammatory reaction at initial periods. Smartpaste Bio® presented the lowest inflammatory reaction at 15 days period (p<0.05). Sealapex® induced higher mineralization, followed by Smartpaste Bio®. Acroseal® showed no mineralization areas. Conclusion: At the end of the experiment, all tested sealers presented biocompatibility. With exception of Acroseal, all induced biomineralization. / Mestre
96

Pentóxido de nióbio como carga para materiais de base polimérica para uso odontológico

Leitune, Vicente Castelo Branco January 2012 (has links)
O objetivo desta tese foi caracterizar o pentóxido de nióbio (Nb2O5), produzir materiais compósitos de matriz polimérica de uso odontológico e avalia-los. As partículas de Nb2O5 foram caracterizadas com difração de raios-X, microscopia eletrônica de varredura, granulometria a laser, método de Brunauer–Emmett–Teller e espectroscopia micro-Raman. Um adesivo experimental foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 5, 10 e 20 %, em peso). Este adesivo foi avaliado quanto à radiopacidade, grau e cinética de conversão, microdureza e a sua interface com a dentina. Um cimento endodôntico experimental de cura dual também foi desenvolvido com a incorporação de diferentes concentrações de Nb2O5 (0, 80, 100 e 120 %, em peso). Este cimento foi avaliado quanto à radiopacidade, escoamento, espessura de película, microdureza e grau de conversão (imediatamente, 7 dias e 14 dias após a fotoativação). A avaliação do Nb2O5 mostrou que as partículas utilizadas apresentavam estrutura monoclínica, com formato irregular, com tamanho médio de 38,16 μm, área de superfície de 3,86 m2/g e estrutura química compatível com pentóxido de nióbio. A radiopacidade e dureza do adesivo aumentaram com a incorporação do Nb2O5 e ele pode ser detectado no interior da interface dentina/adesivo. No cimento endodôntico a incorporação do Nb2O5 também aumentou a radiopacidade e a dureza e reduziu o escoamento apenas no grupo com 120 %. O grau de conversão aumentou até 14 dias após a fotoativação, com exceção do grupo com 80%. Após a caracterização do Nb2O5 e da produção dos materiais experimentais, foi feito o depósito de pedido de patente de invenção. Conclui-se que o pentóxido de nióbio é uma nova e promissora partícula para uso em Odontologia como agente de carga. / The aim of this thesis was to characterize the niobium pentoxide (Nb2O5), to produce resin-based composite for dental applications and evaluate them. Niobium pentoxide was characterised by X-ray diffraction, surface area, particle size, micro-Raman and scanning electron microscopy. An experimental adhesive resin was formulated with 0, 5, 10 and 20 wt% Nb2O5. The formulated adhesive resins were evaluated based on microhardness, degree of conversion, radiopacity and interface (resin/dentin) characterisation by micro-Raman. An experimental dual-cured root canal sealer was produced with a methacrylate-based comonomer blend. Nb2O5 was added at four different concentrations: 0, 80, 100 and 120wt%. Radio-opacity, flow, film thickness, microhardness and degree of conversion (after 1, 7 and 14 days) were evaluated. The particles used in this study presented a monoclinic crystalline phase with typical chemical groups, mean size of 38.16 μm and 3.86 m2/g of surface area. Microhardness and radiopacity increased with higher amounts of Nb2O5, and the particles were able to penetrate into the hybrid layers. Microhardness and radiopacity increased with higher amounts of Nb2O5 in the adhesive resin, and the particles were able to penetrate into the hybrid layers. For the endodontic cement, the radiopacity and microhardness increased with the Nb2O5 addition. The flow was significantly smaller for the 120% group. All groups except those with 80wt% had higher values for degree of conversion after 14 days than immediately after photocuring. After the Nb2O5 characterization and the production of experimental materials, an application for patent was done. Niobium pentoxide is a new and promising filler for dental materials production.
97

Avaliação do comportamento biológico do cimento endodôntico MTA Fillapex em tecido ósseo de ratos / Evaluation of rat bone tissue response to MTA Fillapex

Assmann, Eloísa January 2013 (has links)
Introdução: A biocompatibilidade é uma propriedade importante e necessária a um cimento endodôntico. O objetivo do presente estudo foi fazer uma análise microscópica das reações do tecido ósseo do fêmur de ratos da linhagem Wistar frente ao cimento MTA Fillapex, comparando-as ao cimento AH Plus e ao grupo controle (cavidade vazia), nos períodos de 7, 30 e 90 dias. Materiais e Métodos: Foram utilizados 18 animais, divididos em 3 grupos, de acordo com o período experimental (n=6). Três cavidades foram preparadas no fêmur da pata traseira direita de cada animal, sendo que uma foi preenchida com AH Plus, a outra com MTA Fillapex e a última permaneceu vazia (controle negativo). Decorridos os períodos experimentais, os ratos foram mortos e as patas removidas, dissecadas e preparadas para análise histológica. Os cortes foram analisados em microscópico óptico. O infiltrado inflamatório e as zonas de calcificação foram avaliados de forma dicotômica (presente ou ausente). A formação de barreira óssea foi classificada como ausente, parcial ou completa. Testes estatísticos não-paramétricos foram utilizados para a comparação dos dados (p<0,05). Resultados: As comparações entre os períodos experimentais mostraram que aos 7 dias todos os grupos apresentaram menor formação de barreira óssea e que o MTA Fillapex apresentou mais áreas de calcificação em relação aos demais períodos. Nos grupos do AH Plus e do MTA Fillapex, o infiltrado inflamatório reduziu significativamente aos 90 dias. As comparações entre os grupos mostraram mais áreas de calcificação no grupo do AH Plus aos 30 e 90 dias. O grupo controle apresentou menos infiltrado inflamatório aos 30 dias. Não houve diferença significativa entre os grupos na formação de barreira óssea. Conclusões: O cimento endodôntico MTA Fillapex apresentou comportamento biológico satisfatório em contato direto com tecido ósseo de rato. As características do reparo foram semelhantes às do cimento AH Plus, porém o MTA Fillapex não induziu a formação de áreas de calcificação na medula óssea. / Introduction: Biocompatibility is an important property required for a endodontic sealer. This study aimed to analyze bone tissue reactions to MTA Fillapex compared to an epoxy resin-based material in the femur of Wistar rats. Methods: Bone tissue reactions were evaluated in 18 animals after 7, 30 and 90 days (n=6 per period). Three surgical cavities were prepared on femur and filled with 0.1 mL of AH Plus, MTA Fillapex or no sealer (negative control). By the end of each experimental period, six animals were randomly euthanized, the femur was dissected and the surgical cavities separated. The samples were histologically processed and analyzed by light microscope. Inflammatory infiltrate and the calcification zones were evaluated dichotomously; hard tissue barrier was classified as absent, partial or full. Results: Comparison among periods showed that at 7 days all groups presented less hard tissue barrier and MTA Fillapex showed more calcification zones than in other periods. The inflammatory infiltrate significantly reduced at 90 days in AH Plus and MTA Fillapex groups. Comparisons among the groups presented more calcification zones for AH Plus than for the other groups at 30 and 90 days. Control group showed less inflammatory infiltrate at 30 days. There were no singificant diferences to hard tissue barrier among the groups. Data were analyzed by non-parameric tests. Significance level was preset in 0.05. Conclusions: MTA Fillapex presented satisfactory biological behaviour when in direct contact with rat bone tissue. The repair characteristics were similar to those produced by AH Plus, but MTA Fillapex doesn’t induce mineralization in the bone marrow.
98

Resistência de união entre um cimento resinoso e uma cerâmica aluminizada submetida a diferentes tratamentos de superfície

Soares, Luiz Felipe [UNESP] 13 May 2003 (has links) (PDF)
Made available in DSpace on 2015-12-10T14:23:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-05-13. Added 1 bitstream(s) on 2015-12-10T14:29:50Z : No. of bitstreams: 1 000200273.pdf: 2866168 bytes, checksum: e0e29948223b178226a3c83ec2622980 (MD5) / Este estudo avaliou a resistência de união entre um cimento resinoso e uma cerâmica submetida a três tratamentos de superfície. Foram confeccionados cinco blocos cerâmicos (Procera AIICeram), com dimensões de 6mm X 6mm X 15mm. Cada bloco foi seccionado em três porções (6mm X 6mm X 5mm). Os quinze blocos obtidos foram duplicados em resina composta (W3D Master) e a superfície cerâmica foi polida com lixas n° 600, 800 e 1200. Os blocos divididos em três grupos experimentais: Grupo 1 - Jateamento com Al2O3 110µm; Grupo 2 - Sistema Rocatec: Rocatec-Pre + Rocatec-Plus + Rocatec-Sil; Grupo 3 - Sistema CoJet: jateamento com partículas especiais de sílica 30µm + ESPE-SiL Os blocos cerâmicos foram cimentados aos de resina composta com o cimento resinoso Panavia F, conforme as instruções do fabricante, sob carga de 750g por 10min. Os blocos cimentados foram armazenados (água destilada/37°C/7 dias) e seccionados em dois eixos, x e y, com disco diamantado sob refrigeração, obtendo-se corpos-de-prova (n=30) com 0,6 ± 0,1 mm2 de área adesiva. Cada cp foi fixado em um paquímetro adaptado para o teste de microtração e o ensaio realizado (velocidade: 1mm.min-1) em máquina de ensaio universal (EMIC DL-1000). Os dados obtidos foram submetidos à análise de variância e teste de Tukey. Os valores médios de resistência de união (MPa) foram: Grupo 1 - 12,70 ± 2,6; Grupo 2-17,06 ± 3,9; Grupo 3 - 18,52 ± 4,72. G2 e G3 apresentaram resistência de união estatisticamente maior que G1. Não houve diferença estatística significante entre G2 e G3 (p<0,05) / This study evaluated the tensile bond strength of a resin cement to a ceramic after to three ceramic surface treatments. Five blocks of Procera AIICeram (6 mm X 6 mm X 15 mm) were fabricated. Each ceramic block was sectioned in 3 portions of 6 mm X 6 mm X 5 mm. The fifteen blocks were duplicata in resin composite (W3D Master); the ceramic surface was polished through 600, 800 and 1200 SiC grids, and the blocks were divided in 3 experimental groups: Group 1- Sandblasting with 110 µm Al203; Group 2- Rocatec System: Racatec-Pre, Plus and -Sil; and Group 3 - CoJet System: Sandblasting with 30µm silica particles + ESPE-Sil. The ceramic blocks were cemented to the resin composite blocks with resin cement (Panavia F), according to manufacturer's instructions, under a load of 750g for 10min. The cemented blocks were stored in 37°C distilled water for 7 days and sectioned in two axes, x and y, with a diamond disk under cooling water in order to obtain samples (sp) with a bonding area of 0,6 ± 0,1 mm2 (n=30). Each sp was attached to an adapted device for the microtensile test. This set was attached to a universal testing machine (EMIC DL-1000) and tested at crosshead speed of 1mm.min-1. The data were statisfically analyzed using ANOVA and Tukey's test. The bond strength mean values (MPa) were: Group 1- 12.70; Group 2- 17.06 and Group 3- 18.52. G2 and G3 showed statistically significant higher bond strength values than G1. There was no statistical difference between G2 and G3 (p<0,05)
99

Resistência de união cerâmica - agente cimentante. Teste de micro-tração e análise por microscopia eletrônica de varredura

Faria, Ricardo Pinheiro de [UNESP] 02 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:31:26Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-12-02Bitstream added on 2014-06-13T20:41:45Z : No. of bitstreams: 1 faria_rp_dr_arafo.pdf: 1705909 bytes, checksum: 0b8648d6813e632a7474c2c61b823912 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Os objetivos deste trabalho foram avaliar a influência de diferentes tempos de condicionamento ácido na resistência de união cerâmica-agente cimentante, por meio do teste de Micro-Tração, bem como análise dos modos de fratura. Foram confeccionados 5 pares de discos de cerâmica de infra-estrutura IPS Empress 2 e divididos aleatoriamente em 5 grupos. As superfícies de união foram regularizadas através de desgaste com lixas abrasivas de granulação seqüencial sob refrigeração. Os espécimes foram nomeados ao acaso e submetidos aos seguintes tratamentos antes da cimentação: G1: sem condicionamento ácido; G2: 20 s de condicionamento com ácido fluorídrico a 10%; G3: 40 s e condicionamento com ácido fluorídrico a 10%; G4: 60 s de condicionamento com ácido fluorídrico a 10% e G5: 2 min de condicionamento com ácido fluorídrico a 10%. Os espécimes, aos pares, foram cimentados com um sistema adesivo e cimento resinoso dual, de acordo com as recomendações do fabricante. Espécimes foram fotopolimerizados, armazenados por 48 h a 37°C e, posteriormente, com auxílio de um disco de diamante perpendicular à superfície de união, palitos com 1 mmø de área de seção foram obtidos. Os valores de resistência de união (MPa) foram obtidos com auxílio de uma máquina de teste universal (MTS 800) e submetidos à análise de variância e teste de Tukey. As médias de resistência foram de 30,20 MPa, 36,19 MPa, 38,72 MPa, 41,43 MPa e 42,53 MPa, respectivamente aos grupos G1, G2 G3 G4 e G5. O grupo G1 apresentou menor resistência média de união do que os demais grupos. O grupo G3 teve comportamento semelhante a G2 e a G4, porém estes dois últimos foram diferentes entre si. Os grupos G4 e G5 promoveram resistências médias semelhantes. Concluímos que o aumento do tempo de condicionamento ácido aumentou os valores de resistência de... . / The purpose of this study was to investigate the effect of different times of acid conditioning on the microtensile bond strength between union-cement and ceramic, and to verify the mode of failure. Five pairs of ceramic disks (IPS Empress 2) were divided, in five groups, by randomized allocation. The bonding surfaces were finished with 600-grit silicon carbide paper. The specimens were nominated at random and submitted to the following treatments before cementation: G1 : without acid etching; G2 : 20 s of etching with 10% hydrofluoric acid; G3 : 40 s of etching with 10% hydrofluoric acid; G4 : 60 s of etching with 10% hydrofluoric acid and G5 : 2 min of etching with 10% hydrofluoric acid. All the pairs were bonded with dual cure resin bonding and dual cure resin cement, according to manufacturer's instructions. The specimens were light-cured and then stored for 48 h at 37°C. Using a diamond disk perpendicular to the bonding interface, 'sticks' with 1.0 mmø cross-sectional area were obtained. Microtensile bond strengths were determined using a MTS 800 Materials Testing Machine at a crosshead speed of 0.5 mm/min. It was applied analysis of variance and Tukey test at p<0.05. The means of microtensile bond strength, in MPa, were 30.20, 36.19, 38.72, 41.43 and 42.53, respectively to the groups G1, G2, G3, G4 and G5. Group G1 had the smallest microtensile bond strength and G3 had similar results when compared to G2 and G4, although G2 and G4 were different between themselves. The groups G4 and G5 showed similar means of microtensile bond strength. Conclusions: The higher the time of acid conditioning higher were the values of microtensile bond strength, and the analysis of mode of failure exhibited prevalence of adhesive failure type.
100

Avaliação da resistência à remoção por tração de coroas metálicas fixadas com cimentos resinosos e da dureza desses materiais em função do método de ativação

Fonseca, Renata Garcia [UNESP] 01 October 2001 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-10-01Bitstream added on 2014-06-13T20:25:47Z : No. of bitstreams: 1 fonseca_rg_dr_arafo.pdf: 347306 bytes, checksum: 7bab875463a1706adf2e01435b649315 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foram avaliados grau de polimerização de cimentos resinosos em função de diferentes intensidades de luz, por meio de ensaio de dureza, e resistência à remoção por tração de coroas cimentadas em troquéis com determinados cimentos. A primeira etapa foi realizada submetendo-se ou não os cimentos resinosos Panavia F, Scothbond Resin Cement, Enforce e Cement-It à fotoativação, tendo as leituras sido realizadas nos tempos imediato, 1 hora, 2 horas, 24 horas e 7 dias após espatulação dos materiais. No segundo ensaio, foram confeccionados troquéis e coroas, ambos em liga de NiCr, os quais, após jateamento e aplicação do agente catalisador do sistema adesivo Scotchbond Multi Uso Plus (3M) em suas superfícies, foram cimentados aos pares com os materiais descritos anteriormente, além do cimento de fosfato de zinco. A análise dos resultados revelou que os cimentos resinosos alcançaram maior dureza nos grupos fotoativados em todos os tempos analisados, com exceção apenas do Scotchbond Resin Cement e Enforce que, aos 7 dias, mostraram igualdade estatística entre os tratamentos. Todos os materiais apresentaram progressão de polimerização em função do tempo na ausência de luz, com diferentes velocidades. Os cimentos Panavia F e Fosfato de Zinco apresentaram, respectivamente, a maior e a menor força de remoção por tração, tendo o Scotchbond Resin Cement, Enforce e Cement-It ficado em posição intermediária, diferenciando-se significativamente dos demais materiais, porém não entre si. / The purpose of this study was to evaluate plymerization degree of resin cements subjected to various light exposures, by hardness test, and bond strength of crowns luted to dies using five luting agents. Panavia F, Scothbond Resin Cement, Enforce and Cement-It were exposed or not to light and measurements were taken at baseline, 1 hour, 1 hours and 7 days after mixing. For the second evaluation, dies and crowns were obtained with NiCr alloys and after sandblasting and treatment with catalyzer agent of Scotchbond Multi Uso Plus adhesive system (3M) at both surfaces, cementation was done with the luting agents described before, besides zinc phosphate cement. Statistical analysis revealed greater hardness for photopolymerized groups in all times, excepting Scotchbond Resin Cement and Enforce that, at 7 days, showed no statistical difference between treatments. All cements had polymerization progression with time at light absence, with different speeds. Panavia F and zinc phosphate showed, respectively, the greatest and smallest bond strength, while Scotchbond Resin Cement, Enforce and Cement-It were in a intermediate position, differing significantly of the other cements, but not between theirserlves.

Page generated in 0.1016 seconds