• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 90
  • 89
  • 13
  • 7
  • 2
  • 2
  • 1
  • Tagged with
  • 203
  • 203
  • 105
  • 82
  • 59
  • 58
  • 53
  • 44
  • 40
  • 38
  • 27
  • 26
  • 24
  • 24
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
121

Avaliação da resistência de união de reparos em resinas compostas convencionais e bulkfill /

Trevisan, Tamara Carolina. January 2016 (has links)
Orientador: Osmir Batista de Oliveira Junior / Banca: Weber Adad Ricci / banca: Gustavo Moncada / Resumo: Técnicas de reparos de restaurações vêm sendo amplamente utilizadas como um tratamento alternativo e conservador á substituição de restaurações defeituosas. O conhecimento do material a ser reparado e de um protocolo ideal, permitiria uma melhor relação biomecânica entre dente e material restaurador e possibilitaria técnicas eficazes e menos invasivas. O objetivo do presente estudo foi avaliar a resistência de união de reparo de diferentes resinas compostas, sob a influência de tratamentos de superfície, especialmente em relação a uma nova proposta comercial denominada de resinas "bulk fill". Para isso, foram confeccionados corpos de prova com diâmetro de 8mm por 4mm de altura, de diferentes classes de resinas compostas: Z350XT, Z250XT, Grandio, Epricord, Tetric Bulkfill, Xtra Fill e Sonic Fill (n=15). Estes passaram por processo de envelhecimento artificial, realizado por meio de armazenamento em estufa com saliva artificial por 3 meses, sendo realizada a troca da saliva semanalmente, e finalizado com termociclagem 5o e 55ºC por 20 segundos em água para 1000 ciclos. Foram distribuídos aleatoriamente em três subgrupos, de acordo com o tratamento de superfície (n=5): G1- Controle- sem tratamento prévio; G2- Jateamento óxido alumínio; G3- Jateamento óxido de sílica. Após a aplicação dos respectivos tratamentos de superfície, cada espécime foi reparado com resina composta Z100 em incrementos de aproximadamente 2mm e fotopolimerizado em um aparelho de fotopolimerização convencion... (Resumo completo, clicar acesso eletrônico abaixo) / Mestre
122

Avaliação clínica retrospectiva de restaurações diretas e indiretas com recobrimento de cúspides / A retrospective clinical evaluation of direct and indirect restorations with cuspal replacement

Berwanger, Carolina dos Santos January 2016 (has links)
Introdução: A crescente demanda por restaurações estéticas possibilitou novas escolhas de tratamento para restaurar dentes posteriores com extensa destruição coronária. Os tratamentos destes dentes podem envolver restaurações diretas com resina composta ou indiretas do tipo onlays, fabricadas com cerâmica pura ou resina composta. Porém, dados clínicos sobre a longevidade de restaurações com recobrimento de cúspides comparando as técnicas direta e indireta e os materiais resina composta e cerâmica são raros. Objetivo: Realizar uma avaliação clínica retrospectiva de restaurações diretas (resina composta) e indiretas (resina composta e cerâmica) com envolvimento de cúspides utilizando o método FDI. Metodologia: Foram avaliadas 229 restaurações em 121 pacientes (37 homens e 84 mulheres) que receberam pelo menos uma restauração direta de resina composta com recobrimento de pelo menos uma cúspide ou uma onlay de cerômero ou cerâmica entre os anos de 2003 e 2016. A avaliação visual foi feita por um examinador previamente calibrado pelo coeficiente Kappa, utilizando-se os critérios do método FDI. Os dados foram analizados através do método Kaplan-Meier, da análise de regressão de Cox multivariada e do teste Kruskal-Wallis (p <0.05). Resultados: Entre as restaurações avaliadas foram detectadas 69 falhas. As restaurações obtiveram uma taxa de sucesso de 69,9%, com taxa anual de falha (AFR) de 8,0%. Restaurações diretas de resina composta apresentaram 34,1% de falha, com AFR de 9,6%. Onlays em cerômero apresentaram 27,3% de falha, com AFR de 7,1%. Onlays de cerâmica apresentaram 28,8% de falha com AFR de 7,6%. Restaurações em homens falharam mais do que em mulheres. A causa mais comum de falha foi fratura e retenção, ocorrendo em 48 casos (69,56% das falhas). Conclusão: Restaurações diretas de resina composta e indiretas de cerômero ou cerâmica demonstraram longevidade semelhante, independente do número de cúspides envolvidas. Restaurações indiretas tiveram menor índice de falha anual do que restaurações diretas, apresentando melhor desempenho na avaliação qualitativa. Pacientes mulheres apresentaram menor prevalência e menor risco de falha de restaurações do que pacientes do sexo masculino. / Introduction: The increasing demand for aesthetic restorations had enabled new treatment choices to restore posterior teeth with extensive coronary destruction. The treatments of these teeth involve direct composite restoration or indirect onlays, made with ceramic or composite. However, clinical data on the longevity of cuspal restorations comparing direct or indirect techniques and the materials are rare. Objective: To perform a retrospective clinical evaluation of direct restorations (composite resin) and indirect restorations (composite resin and ceramics) with cuspal involvement using the FDI criteria. Methodology: 229 restorations were evaluated in 121 patients (37 men and 84 women) who received at least one direct composite restoration with envolvement of at least one cusp or ceramic and composite onlays among the years 2003 and 2016. The visual evaluation was done by an examiner previous calibrated by the Kappa coefficient, using the FDI criteria. Data were analyzed by the Kaplan-Meier method, multivariated Cox regression analysis and Kruskal-Wallis test (p<0.05). Results: Among the evaluated restorations, 69 failures were detected. Restorations achieved a survival rate of 69.9%, with annual failure rate (AFR) of 8.0%. Direct composite restorations presented a 34.1% failure, with AFR of 9.6%. Composite onlays presented 27.3% of failure, with AFR of 7.1%. Ceramic onlays showed a 28.8% failure rate with AFR of 7.6%. Restorations in men have failed more than in women. The most common reason for failure was fracture of the material and retention, occuring in 48 cases (69.56% of failures). Conclusion: Direct and indirect restorations showed similar longevity, regardless of the number of cusps involved. Indirect restorations had lower annual failure rate than direct restorations, presenting better performance in the qualitative analisys. Female patients presented lower prevalence and lower risk of failure of restorations than male.
123

Longevidade de restaurações adesivas em dentes decíduos posteriores submetidos à remoção total ou seletiva de tecido cariado : um estudo multicêntrico / Longevity of adhesive restorations performed on primary teeth after total or selective caries removal : a multicentric clinical trial

Pereira, Joanna Tatith January 2016 (has links)
A técnica da remoção seletiva de tecido cariado (RSTC) para lesões de cárie profundas em dentina de dentes decíduos e permanentes, já é consenso na literatura e é sustentada por pesquisas que demonstram excelentes resultados clínicos, radiográficos e microbiológicos. No entanto, a longevidade de restaurações adesivas realizadas após a RSTC, principalmente na dentição decídua, vem gerando algumas dúvidas e preocupações quanto ao seu desempenho, merecendo esclarecimentos. O objetivo deste estudo randomizado, controlado e multicêntrico foi comparar a taxa de sucesso de restaurações adesivas realizadas em dentes decíduos posteriores após a remoção total (RTTC) ou seletiva (RSTC) de tecido cariado ao longo de 30 meses. Métodos: Crianças de 4 a 8 anos de idade portadoras de pelo menos duas lesões cavitadas ativas em metade interna de dentina (metade interna da dentina na avaliação do RX interproximal e com pelo menos 1mm de dentina separando a lesão cariosa da polpa) e que se enquadrassem nos critérios de inclusão e exclusão participaram do estudo. Para cada criança os dentes (no mínimo dois, mas podendo ser mais) foram aleatoriamente divididos de acordo com os seguintes tratamentos: RTTC (grupo controle) ou RSTC (grupo teste). Nos casos em que ocorreu exposição pulpar, o dente foi devidamente tratado e excluído da amostra, os dados em relação ao tipo de remoção de tecido cariado que levou à exposição foram coletados. Quatro instituições participaram do estudo (Universidade Federal do Rio Grande do Sul; Universidade de São Paulo; Universidade Peruana Cayetano Heredia; Universidade Internacional do Equador), resultando em quatro odontopediatras que realizaram os procedimentos de remoção de tecido cariado e posterior restauração em resina composta, avaliadas clinicamente no baseline, 6, 12, 18, 24 e 30 meses. Todos os procedimentos foram realizados sob anestesia local e isolamento absoluto. Características sociodemográficas foram coletadas no baseline e características clínicas como índice ceod/CPOD, índice de placa visível (IPV) e índice de sangramento gengival (ISG) foram coletados em todos os períodos de acompanhamento. Em todos os momentos experimentais foram avaliados os aspectos clínicos das restaurações por um examinador cego e calibrado através do índice FDI adaptado. Para determinar as taxas de sucesso das restaurações de resina composta foram geradas curvas de sobrevida com o estimador Kaplan-Meyer para cada grupo avaliado, assim como as taxas de falha anual das restaurações. O modelo de regressão de Cox com falhas compartilhadas foi realizado para avaliar diferenças nas taxas de sobrevida das restaurações de acordo com o tratamento, instituição e características clínicas e demográficas da amostra. Resultados: Cento e seis crianças (51 meninos e 55 meninas) colaboraram com 278 dentes submetidos a restaurações adesivas, 137 após RTTC e 141 após RSTC. Oito exposições pulpares ocorreram no grupo da RTTC e quatro no grupo da RSTC. A taxa global de sucesso das restaurações foi 87,1% (85,4% para RTTC e 88,7% para RSTC) e o tempo médio de sobrevida foi de 30 meses. A taxa anual de falha foi de 7% após 24 meses de acompanhamento. Não houve diferença no risco de falha (TR) de acordo com o grupo de tratamento (TR 0,75; IC 95%: 0,38-1,46) e instituição (USP TR 0,44; IC 95%: 0,94-2,09; PERU TR 0,92; IC 95%: 0,26-3,19 EQUADOR TR 1,39; IC 95%: 0,45-4,28). Foram encontradas observações análogas em relação a todas as variáveis clínicas e demográficas. Conclusões: As restaurações adesivas realizadas em dentes decíduos com lesões cavitadas profundas em dentina apresentam sobrevida satisfatória após 33 meses de acompanhamento, independentemente da técnica realizada para remoção de tecido cariado. / The selective caries removal technique (SCR) for active deep carious lesions in deciduous and permanent teeth is already a consensus in the literature and is supported by studies that demonstrate excellent clinical, radiographic and microbiological results. However, the longevity of restorations performed after the SCR, mainly in primary dentition, has generated some doubts and concerns about its performance, deserving clarification. This multicenter study aimed to compare the success rate of adhesive restorations performed on posterior deciduous teeth after total or selective caries removal over 30 months Methods: Children between 4 - 8 years old with at least two active cavitated lesions in deep dentin (inner half of the dentin in the evaluation of the interproximal RX and with at least 1mm of dentin separating the carious lesion of the pulp) and that met the inclusion and exclusion criteria participated in the study. For each child, teeth were randomized and submitted to one of the treatment groups: total caries removal (TCR - control group) or SCR (test group). Children could have more than 2 teeth included. In cases of pulp exposure, data were analyzed and the tooth was excluded from the sample. Four institutions participated in the study (Federal University of Rio Grande do Sul, Peruvian University Cayetano Heredia and International Universidad of Ecuador), resulting in four pediatric dentists who performed the caries removal procedures and subsequent restorations in composite resin. Clinical evaluation was performed at baseline, 6, 12, 18, 24 and 30 months. All procedures were performed under local anesthesia and rubber dam use. Sociodemographic characteristics were collected at the baseline and clinical characteristics as dmft and visible plaque and gingival bleeding index were collected in all follow-up periods. Radiographs were taken only at baseline and restorations were clinically assessed at baseline, 6, 12, 18, 24 and 33 months by a blinded, trained and calibrated operator in each institution. The characteristics of the restorations were recorded according to an adaptation of the FDI criteria. Survival estimates for restoration longevity were evaluated using the Kaplan-Meier method. We also estimated the annual failure rate of the restorations. Cox regression model with shared frailty was performed to assess differences in survival rates of the restoration according to the intervention treatment, institution and clinical and demographic characteristics of the sample. Results: one hundred and six children (51 boys and 55 girls) collaborated with 278 teeth submitted to adhesive restorations (137 after TCR and 141 after SCR). Pulp exposure occurred in eight teeth (2.8%) allocated to TCR, and in four (1.4%) allocated to SCR group. The overall success rate of restorations was 87.1% (85.4% for TCR and 88.7% for SCR) and mean survival time was 30.3 months. The annual failure rate was 7% after 24 months of follow-up. There were no differences in the risk of failure according to the treatment group (HR 0.75;95%CI:0.38-1.46) and institution (USP HR 0.44;95%CI:0.94-2.09; PERU HR 0.92;95%CI:0.26-3.19; ECUADOR HR 1.39;95%CI:0.45-4.28). Analogous observations were found regarding all the clinical and demographic variables. Conclusions: Composite restorations of active deep carious lesions performed in posterior primary teeth show satisfactory survival of 87.1% after 33 months of follow-up, regardless of the technique performed for carious tissue removal.
124

Avaliação clínica retrospectiva de restaurações estéticas : classe III, IV e V / Retrospective clinical evaluation of esthetic restorations : class III, IV and V

Vieira, Rodrigo Monteiro January 2015 (has links)
O objetivo do presente estudo foi realizar uma avaliação clínica retrospectiva de restaurações diretas de resina composta de classe III, IV e V em dentes anteriores e pré-molares utilizando os métodos USPHS e FDI. Oitenta e sete pacientes foram selecionados através de uma pesquisa dos prontuários presentes no Setor de Acolhimento da Faculdade com restaurações realizadas entre 2000 a 2013 que possuíam um período mínimo em boca de 6 meses. Foram incluídos pacientes adultos de ambos os sexos que receberam tratamento com restaurações de classe III, IV ou V realizadas com as resinas compostas: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic e Opallis; realizadas com sistema adesivo convencional; em dentes vitais ou não vitais. Aqueles pacientes que possuíam higiene oral precária ou com necessidades especiais não foram incluídos no estudo. A avaliação clínica foi feita através dos métodos USPHS e FDI modificados por um examinador calibrado. A análise de sobrevivência das restaurações foi realizada através do método Kaplan-Meier e teste Log-Rank para comparação entre os grupos. A regressão de Cox multivariada e Hazard Ratio foram empregadas para verificar os fatores associados à falha das restaurações. O nível de significância foi de 5%. Foram avaliadas 272 restaurações, com um intervalo de tempo em boca de 8 meses até 13 anos (média - 4,8 anos). Foram avaliadas 120 restaurações classe III, entre elas, 15 apresentaram falhas (12,5%), com uma taxa de falha anual de 2,74%. Já para as restaurações de classe IV, realizou-se a avaliação de 80 restaurações, 38 demonstraram falhas (47,5%), como uma taxa de falha anual de 12,6%. E para as de classe V, foram analisadas 72 restaurações, sendo observada a presença de falhas em 27 delas (37,5%), com uma taxa de falha anual de 9,3%. O motivo mais comum de falha foi por fratura e/ou retenção para as três classes, ocorrendo em 73 casos. Dentes não vitais demonstraram 50% de falha em um tempo médio de 4,8 anos com uma taxa de falha anual de 13,4%; enquanto os dentes vitais apresentaram 28,1% de falha com uma taxa de falha anual de 6,6%. A regressão de Cox revelou associação entre marca comercial do compósito, classe da restauração e vitalidade pulpar com falha das restaurações. Conclui-se que restaurações de resina composta demonstraram um desempenho clínico satisfatório ao longo do tempo, apresentando sucesso em 70,6% dos casos em uma média de 4,8 anos, sendo que as de classe III apresentaram melhor desempenho clínico que classe V e classe IV e as restaurações em dentes desvitalizados apresentaram 2,37 vezes mais risco de falhas que restaurações em dentes vitais. Os principais motivos de falha para todos os tipos de restauração foi por fratura e/ou perda de retenção. Os dois métodos (USPHS e FDI) se demonstraram eficazes no processo de avaliação clínica em restaurações em dentes anteriores. / The aim of this study was to evaluate direct composite restorations Class III, IV, V in anterior teeth and premolars through the USPHS and FDI methods. Eighty-seven patients were selected through a search of the patients’ records present in the School of Dentistry. Restorations performed between 2000 to 2013 which a minimum of six months in mouth were selected. Adult patients of both sexes were included, who received treatment with restorations class III, IV or V with the follow composites: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic and Opallis; all restorations with total etch adhesive system; on vital and non-vital teeth. Patients with poor oral hygiene or special needs were not included in the study. Clinical evaluation was performed by USPHS and FDI modified methods, by one calibrated examiner. The survival of the restorations was analyzed using the Kaplan-Meier method and log-rank test to compare the groups, and multivariate Cox regression and hazard ratio were employed to identify factors associated with the failure of the restorations. The significance level was 5%. 272 restorations were evaluated with a time interval in service from 8 months to 13 years (mean 4.8 years). 120 class III restorations were evaluated, among them, 15 had failures (12.5%), with an annual failure rate of 2.74%. For the class IV type, 80 restorations were evaluated, 38 demonstrated failures (47.5%), with an annual failure rate of 12.6%. And for the class V, 72 restorations were analyzed, being observed the presence of failures in 27 of them (37.5%), with annual failure rate of 9.3% .The most common reason for failure was fracture or retention loss, for the three types of classes, occurring in 73 cases. Non-vital teeth showed 50% of failure in an average of 4.8 years, with an annual failure rate of 13.4%; while the vital teeth showed 28.1% of failure, with an annual failure rate of 6.6%. Cox regression revealed an association between brands, class type and tooth vitality with failures of the restorations. It was concluded that composite restorations showed a satisfactory clinical performance over time, with success in 70.6% of cases in a mean time of 4.8 years. Class III showed better clinical performance than class IV and V. Non-vital teeth restorations had 2.37 times the risk of failures than vital teeth. The main reasons for failure for all types of restoration was fracture and / or retention loss. Both methods (USPHS and FDI) demonstrated efficient in the process of clinical evaluation for anterior teeth.
125

Avaliação clínica retrospectiva de restaurações estéticas : classe III, IV e V / Retrospective clinical evaluation of esthetic restorations : class III, IV and V

Vieira, Rodrigo Monteiro January 2015 (has links)
O objetivo do presente estudo foi realizar uma avaliação clínica retrospectiva de restaurações diretas de resina composta de classe III, IV e V em dentes anteriores e pré-molares utilizando os métodos USPHS e FDI. Oitenta e sete pacientes foram selecionados através de uma pesquisa dos prontuários presentes no Setor de Acolhimento da Faculdade com restaurações realizadas entre 2000 a 2013 que possuíam um período mínimo em boca de 6 meses. Foram incluídos pacientes adultos de ambos os sexos que receberam tratamento com restaurações de classe III, IV ou V realizadas com as resinas compostas: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic e Opallis; realizadas com sistema adesivo convencional; em dentes vitais ou não vitais. Aqueles pacientes que possuíam higiene oral precária ou com necessidades especiais não foram incluídos no estudo. A avaliação clínica foi feita através dos métodos USPHS e FDI modificados por um examinador calibrado. A análise de sobrevivência das restaurações foi realizada através do método Kaplan-Meier e teste Log-Rank para comparação entre os grupos. A regressão de Cox multivariada e Hazard Ratio foram empregadas para verificar os fatores associados à falha das restaurações. O nível de significância foi de 5%. Foram avaliadas 272 restaurações, com um intervalo de tempo em boca de 8 meses até 13 anos (média - 4,8 anos). Foram avaliadas 120 restaurações classe III, entre elas, 15 apresentaram falhas (12,5%), com uma taxa de falha anual de 2,74%. Já para as restaurações de classe IV, realizou-se a avaliação de 80 restaurações, 38 demonstraram falhas (47,5%), como uma taxa de falha anual de 12,6%. E para as de classe V, foram analisadas 72 restaurações, sendo observada a presença de falhas em 27 delas (37,5%), com uma taxa de falha anual de 9,3%. O motivo mais comum de falha foi por fratura e/ou retenção para as três classes, ocorrendo em 73 casos. Dentes não vitais demonstraram 50% de falha em um tempo médio de 4,8 anos com uma taxa de falha anual de 13,4%; enquanto os dentes vitais apresentaram 28,1% de falha com uma taxa de falha anual de 6,6%. A regressão de Cox revelou associação entre marca comercial do compósito, classe da restauração e vitalidade pulpar com falha das restaurações. Conclui-se que restaurações de resina composta demonstraram um desempenho clínico satisfatório ao longo do tempo, apresentando sucesso em 70,6% dos casos em uma média de 4,8 anos, sendo que as de classe III apresentaram melhor desempenho clínico que classe V e classe IV e as restaurações em dentes desvitalizados apresentaram 2,37 vezes mais risco de falhas que restaurações em dentes vitais. Os principais motivos de falha para todos os tipos de restauração foi por fratura e/ou perda de retenção. Os dois métodos (USPHS e FDI) se demonstraram eficazes no processo de avaliação clínica em restaurações em dentes anteriores. / The aim of this study was to evaluate direct composite restorations Class III, IV, V in anterior teeth and premolars through the USPHS and FDI methods. Eighty-seven patients were selected through a search of the patients’ records present in the School of Dentistry. Restorations performed between 2000 to 2013 which a minimum of six months in mouth were selected. Adult patients of both sexes were included, who received treatment with restorations class III, IV or V with the follow composites: Charisma, Z350 XT, Durafill VS, Esthet-X HD, Fillmagic and Opallis; all restorations with total etch adhesive system; on vital and non-vital teeth. Patients with poor oral hygiene or special needs were not included in the study. Clinical evaluation was performed by USPHS and FDI modified methods, by one calibrated examiner. The survival of the restorations was analyzed using the Kaplan-Meier method and log-rank test to compare the groups, and multivariate Cox regression and hazard ratio were employed to identify factors associated with the failure of the restorations. The significance level was 5%. 272 restorations were evaluated with a time interval in service from 8 months to 13 years (mean 4.8 years). 120 class III restorations were evaluated, among them, 15 had failures (12.5%), with an annual failure rate of 2.74%. For the class IV type, 80 restorations were evaluated, 38 demonstrated failures (47.5%), with an annual failure rate of 12.6%. And for the class V, 72 restorations were analyzed, being observed the presence of failures in 27 of them (37.5%), with annual failure rate of 9.3% .The most common reason for failure was fracture or retention loss, for the three types of classes, occurring in 73 cases. Non-vital teeth showed 50% of failure in an average of 4.8 years, with an annual failure rate of 13.4%; while the vital teeth showed 28.1% of failure, with an annual failure rate of 6.6%. Cox regression revealed an association between brands, class type and tooth vitality with failures of the restorations. It was concluded that composite restorations showed a satisfactory clinical performance over time, with success in 70.6% of cases in a mean time of 4.8 years. Class III showed better clinical performance than class IV and V. Non-vital teeth restorations had 2.37 times the risk of failures than vital teeth. The main reasons for failure for all types of restoration was fracture and / or retention loss. Both methods (USPHS and FDI) demonstrated efficient in the process of clinical evaluation for anterior teeth.
126

Influência do ultra-som na resistência à abrasão e na rugosidade de superfície dos cimentos de ionômero de vidro submetidos à escovação / Influence of the ultrasound in the abrasion resistance and in superficial roughness of the glass ionomer cements submitted to toothbrush

Renata Loureiro Louro 30 March 2007 (has links)
O objetivo deste estudo foi avaliar o desgaste à abrasão decorrente da escovação simulada de cimentos de ionômero de vidro sonificados, por análise da alteração de massa e da textura superficial. Os materiais avaliados foram: Fuji II LC (GC América), Resiglass (Biodinâmica), Vitro Fil LC (DFL), Fuji IX (GC América), Ketac Molar (3M ESPE), Vitro Molar (DFL), Bioglass (Biodinâmica), Vitro Fil (DFL), que foram manipulados conforme instruções do fabricante, constituindo-se no grupo controle, e um grupo submetido ao ultra-som EMS FT-081 DN Mini PIEZON (EMS, Nyon, Geneva, Switzerland), constituindo-se no grupo experimental. Os corpos-deprova foram confeccionados em uma matriz de dente bovino, com um orifício central com dimensões de 5mm de diâmetro e 3mm de espessura. Foram confeccionados 10 corpos-de-prova para cada material e cada grupo (experimental e controle). O teste de simulação da escovação foi realizado numa máquina automática para simulação de escovação (M.N. São Carlos - Brasil). A alteração de massa foi verificada pela diferença entre a massa inicial (antes da escovação) e final (após a escovação), em balança de precisão (cap. 210g, sens. 0,0001g mod. Mark 210A LICiT-Bel/Proc. Italian), com precisão de quatro casas decimais. A análise da rugosidade superficial em Ra foi determinada pela diferença entre as médias de cinco leituras, iniciais e finais, com um rugosímetro Hommel Tester T1000 (Hommelwerke, GmbH, Alte Tuttinger Strebe 20. D-7730 VS-Schwenningen). Os resultados obtidos foram submetidos à análise de ANOVA a dois critérios e Tukey (p<0,05). Quanto à perda de massa não houve diferença estatisticamente significante em relação à aplicação do ultra-som (p=0,403). No entanto, houve diferença estatisticamente significante para os diferentes Ionômeros estudados, onde p<0,001, mais precisamente do Resiglass e do Vitro Molar com os demais materiais. No que se refere à alteração de rugosidade houve diferença estatisticamente significante para a condição utilização ou não do ultra-som (p=0,043), mas não para os diferentes materiais estudados, onde p=0,264. A excitação ultra-sônica durante a presa inicial piora a rugosidade de superfície e não apresenta nenhuma influência na perda de peso. / The purpose of this work was to evaluate abrasion resistance, by means of weight loss, and surface roughness (SR) of GIC, using ultrasonic excitation as a command set. The materials tested were Fuji II LC and Fuji IX (GC Corporation), Ketac Molar (3M ESPE), Resiglass and Bioglass (Biodinâmica), Vitro Fil LC, Vitro Molar and Vitro Fil (DFL). Twenty specimens of each GIC brand were evaluated, being half submitted to ultrasound (US) (Piezon - EMS, Switzerland). The materials were placed in bovine tooth matrix (5mm inner diameter and 3mm of thickness). Initial weight was carried out by means of a digital balance (210A LICiT/Italian). The initial SR was quantitatively assessed by measuring the surface roughness using Hommel Tester T1000 (Hommelwerke, Germany) determined by the average of 5 random measurements in each sample. The specimens were submitted to brushing abrasion test. Weight loss and surface roughness, for each specimen were calculated based on the difference between the initial and final weight and surface roughness means, respectively. Weight loss (g) varied between 0,0001 and 0,0090 with US and 0,0001 and 0,0123 without US. Surface roughness (µm) varied between 0,0770 and 0,4330 with US and -0,0270 and 0,3520 without US. The results, analyzed by two way ANOVA and Tukey\'s test (p<0,05), presented statistically significant difference in the surface roughness when the GIC was submitted or not to US (p=0,043) while no statistical difference was observed among the GIC brands (p=0,264). The weight loss presented statistically significant difference between the tested GIC brands (p<0,010), while no influence on the weight loss by the use of US was observed (p=0,403). Ultrasonic excitation during initial cure does not improve surface roughness of GIC, and does not present any influence on weight loss.
127

Resistência à corrosão de amálgamas e de liga à base de gálio, sem e com adesivos, através do método de perda de peso e análise da rugosidade de superfície.

Paulo Humaitá de Abreu 10 May 2002 (has links)
Avaliou-se a resistência à corrosão pelos testes de perda de peso em imersão alternada (solução-ar) e as conseqüentes alterações produzidas nas superfícies dos três materiais restauradores (os amálgamas Dispersalloy e Tytin Plus, ambos de alto conteúdo de cobre, respectivamente do tipo fase dispersa e do tipo partícula única, assim como a liga à base de gálio Galloy), não ou associados a dois sistemas adesivos (All-Bond 2 e PAAMA-2), observadas através da medição da rugosidade de superfície. Confeccionou-se dez corpos-de-prova, para cada condição específica, a partir de uma matriz metálica de aço inoxidável contendo cinco cavidades cilíndricas, com 10,7 mm de diâmetro por 3,0 mm de altura cada uma. Após o polimento, como é feito no caso de análises metalográficas, os espécimes foram pesados e levados ao rugosímetro para realizar as medições imediatamente. Estes foram submetidos à imersão alternada, na solução de sulfeto de sódio a 5 %, por um período de 24 horas e novamente foi realizada a pesagem e obtidos os valores de perda de peso. Depois da pesagem, os corpos-de-prova foram levados novamente ao rugosímetro para obtenção dos valores médios de rugosidade de superfície. Os resultados foram registrados e submetidos à análise de variância, a dois critérios, e ao teste de contrastes de Tukey-Kramer. Dos resultados obtidos, conclui-se que todos os espécimes perderam peso e tiveram sua rugosidade de superfície aumentada após a imersão em solução corrosiva; a liga Galloy mostrou valores maiores, tanto no método de perda de peso como no de rugosidade de superfície, quando comparada aos dois amálgamas; a liga Tytin Plus alcançou os melhores resultados; houve diferença estatisticamente significante entre os materiais restauradores, mas não entre os sistemas adesivos utilizados, mostrando comportamentos diferentes dependendo da combinação desses fatores. / The resistance to the corrosion was evaluated through weight loss to an alternated immersion (solution-air) and its consequent changes on the surface of three restoring materials (them amalgams Dispersalloy and Tytin Plus, both with high copper content, respectively dispersion phase and unique particle, as well as the alloy gallium base Galloy), associated or not to two adhesive systems (All-Bond 2 and PAAMA-2), observed by measuring the surface roughness. Ten bodies-of-test were made, for each specific condition, in a metallic matrix os stainlesss steel with five cilindrical cavities, measuring 10,7 mm in diameter and 3,0 mm thickness each one. After polishing, as in the metalographic anal ysis, the specimens were weighed and submitted to the roughness measurer to measuring inicial. These were submitted to an alternated immersion in 5 % sodium sulfide solution, for 24 hours and then the second weighting was performed and obtained the average values of weight loss. A second measure of the surface roughness was then performed. The results were registered and submitted to the variance analysis, to two approaches, and to the test of contrasts of Tukey-Kramer. From the obtained results, it was concluded that all specimens lost weight and there was an increasing roughness surface after immersion in corrosive solution; Galloy showed higher values, both weight loss test and the rougness surface, compared to two amalgams; the alloy Tytin Plus obtained better results; there was significant statistical difference among the restoring materials, but not among adhesive systems, showing different behaviors according to arrangement of these factors.
128

Avaliação do comportamento mecânico de próteses fixas provisórias durante e após ensaio de fadiga - efeito de três tipos de reforços (fibra de vidro, fibra de aramida e fio de aço) e duas extensões de pôntico (12,5 e 22,75mm)

Luiz Gustavo Cavalcanti Bastos 27 June 2006 (has links)
A importância das próteses provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a execução destas restaurações, entretanto, são críticos com relação à resistência e à longevidade, principalmente quando estas são executadas em tratamentos prolongados e/ou em espaços desdentados extensos. A proposta deste trabalho foi determinar através de um ensaio de fadiga e de um teste de resistência à fratura, o efeito do tipo de reforço: fio de aço Ø 0,7 mm, fibra de poli(aramida) (Kevlar®, DuPont - USA) e fibra de vidro (Fibrante®, Ângelus -Brasil) e de duas extensões do pôntico (12,5 e 22,75 mm) sobre o comportamento mecânico de espécimes simulando próteses provisórias. Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo CONTROLE, sem reforço. Os espécimes simulando próteses parciais fixas provisórias foram confeccionados em resina auto-polimerizável com auxílio de uma matriz de aço simulando preparos totais protéticos. As amostras foram submetidas a 10.000 ciclos de fadiga, com carga máxima de 100 N, imersas em água a 37ºC. Através da análise estatística dos resultados observou-se que durante o ensaio de fadiga: 1) quando a extensão do pôntico foi de 22,75 mm, o grupo CONTROLE exibiu uma maior deformação a partir de 500 ciclos. Não foram observadas diferenças quando a extensão do pôntico foi de 12,5 mm. Houve um aumento da deformação em função do número de ciclos para todos os grupos, principalmente para o grupo CONTROLE, de ambas as extensões de pôntico; 2) Somente espécimes do grupo CONTROLE com extensão do pôntico de 22,75 mm demonstraram fraturas à fadiga. E após o ensaio de fadiga, através de um teste de resistência à fratura: 1) Quando a extensão do pôntico foi de 12,5 mm todos os grupos reforçados apresentaram valores médios do limite de elasticidade, em N, significantemente maiores que os demonstrados pelo grupo CONTROLE. Para a extensão do pôntico de 22,75 mm os valores desse parâmetro apresentaram semelhança entre todos os grupos; 2) Em relação à carga máxima (resistência à fratura), quando a extensão do pôntico foi de 12,5 mm o grupo FIBRANTE exibiu o maior valor médio. Quando a extensão do pôntico foi de 22,75 mm, observou-se que o grupo KEVLAR apresentou valores semelhantes neste parâmetro ao grupo FIBRANTE. O grupo CONTROLE sempre apresentou os menores valores médios em ambas as extensões de pôntico. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo parcial (coesiva da resina sem fratura ou separação do reforço). / Provisional restorations are essential components of oral rehabilitation treatment. The strength and durability features are, however, critical when long-term treatment is needed. This study investigates the mechanical alterations under and after cyclic fatigue in provisional partial fixed denture specimens. Two pontic distances (12.5 mm and 22.75 mm) and three types of reinforcements constituted the experimental groups with ten specimens each: a 0.7 mm of diameter wire; a roving poliaramid fiber Kevlar® and a roving fiberglass Fibrante® (Angelus®). The control group, also with ten samples, included not reinforced specimens. Specimens were fabricated and testing on metal dies. The samples were subjected to 10,000 fatigue cycles with a 100 N maximum load in a MTS 810 Universal Machine and before they were subjected to fracture resistance test in the same machine. Statistical analysis showed that, during the fatigue cycles: 1) All the samples exhibited an increased deflection, in mm, following the fatigue cycles, mainly the CONTROL group; 2) Only specimens of the CONTROL group exhibited fracture due to fatigue cycle. After the fatigue cycle, through the fracture resistance test: 1) All reinforced samples with the pontic distance of 12.5 mm exhibited higher figures in elastic limits than the CONTROL group, and increased the pontic distance to 22.75 mm the results of the elastic limits decreased statistically; 3) the FIBRANTE group with pontic distance of 12.5 mm exhibited the higher results for the resistance fracture. The CONTROL group specimens, with both pontic distances, exhibited the lowest values of this property; 4) It was observed that the reinforced FIBRANTE anda KEVLAR groups specimens fractures were more favorable, occurring, predominantly, in the Partial type.
129

Incidência de fraturas em próteses fixas: estudo retrospectivo. Análise da sobrevivência de próteses metalocerâmicas após um período mínimo de quatro anos em função / Fractures Incidence on fixed prostheses: a retrospective study

Fabiola Pontes Azevedo 09 August 2017 (has links)
As próteses metalocerâmicas ainda são apontadas como o tratamento de escolha em reabilitação oral por apresentarem altas taxas de sobrevivência, mesmo que o fator estético possa ser comprometido devido às propriedades óticas relacionadas à infraestrutura metálica. Além disso, há pouca informação na literatura científica sobre os fatores que levam às fraturas das próteses fixas metalocerâmicas. Com isso, o presente estudo teve como objetivo avaliar se a quantidade de elementos que compõe uma prótese, se a quantidade de elementos por retentor, se o tipo de prótese, se o tipo de pilar, se a localização da prótese, se o bruxismo e se a utilização de placa miorrelaxante influenciam na incidência de fraturas em próteses fixas metalocerâmicas. Para este estudo, foram selecionados 16 pacientes, totalizando 74 próteses metalocerâmicas, instaladas entre 2000 e 2010, que tiveram um acompanhamento mínimo de 4 anos. Foram coletados dados, como: gênero, idade, data de instalação das próteses e sistema cerâmico utilizado. Foi realizada a avaliação clínica considerando integridade da prótese, características do elemento antagonista e coleta da história odontológica em caso de fratura, além de um questionário para identificar provável ou possível bruxismo. Foram determinadas as taxas de sucesso, insucesso e sobrevivência da mesma. Os resultados mostraram que a taxa de sucesso das próteses metalocerâmicas instaladas foi de 87,8% e a taxa de sobrevivência foi de 89,1%. Além disso, a taxa de sucesso não foi influenciada pela idade (p=0,903), tempo de instalação (p=0,830), número de próteses na boca (p=0,872), número de elementos (p=0,937) e número de pilares (p=0,064). Para as variáveis qualitativas também não houve diferença estatística significante (p>0,05) entre as proporções das taxas de sucesso e insucesso. Contudo, os resultados mostraram que pacientes que não usavam placa miorrelaxante tiveram taxa maior de sucesso que os pacientes usuários de placa (p=0,004). Assim, pode-se concluir que as próteses metalocerâmicas apresentam altas taxas de sucesso e sobrevida garantindo a longevidade desse tipo de reabilitação. / Metal-ceramic prosthesis are still the treatment choice in oral rehabilitation because they present high survival rates, even if the aesthetic can be compromised due to optical properties related to metallic infrastructure. In addition, there is little information on scientific literature about factors that lead to fractures of fixed metalceramic prosthesis. The purpose of this study was to evaluate if prosthesis elements number, number of elements per prosthetic abutment, type of prosthesis, type of prosthetic abutment, the prosthesis location, bruxism and myorelaxant plaque influences on incidence of fractures in fixed metal-ceramic prosthesis. For this study, 16 patients were selected totaling 74 metal-ceramic dentures installed between 2000 and 2010 with a follow-up of at least 4 years. Data were collected, such as: gender, age, prosthesis installation date and the ceramic system used. Besides a questionnaire to identify probable or possible bruxism, a clinical evaluation was performed to evaluate prosthesis integrity, antagonist element characteristics and dental history in case of fracture. Success, failure and survival rates were determined. The results showed that the success rate of metal-ceramic prosthesis was 87.8% and the survival rate was 89.1%. In addition, the success rate was independent of age (p=0.903), installation time (p=0.830), number of prosthesis (p=0.872), elements (p=0.937) and abutments (p=0.064). The qualitative variables also did not show significant statistical results (p> 0.05) between success and failure rates. However, the results showed that patients who did not use myorelaxant plaque had a higher success rate than plaque users (p=0.004). Thus, it can be concluded that the metal-ceramic prosthesis has high success and survival rates, ensuring longevity of this type of rehabilitation.
130

Avaliação da resistência à fratura de próteses fixas provisórias implanto-suportadas variando o comprimento do cantilever e o tipo de fibra: fibras de vidro e fibras de poli(aramida) / Evaluation of the resistance to the fracture of temporary fixed prostheses implant-supported varying the extension of the cantilever and the fiber type: glass fibers and poliaramid fibers

Paola del Rosario Colán Guzmán 01 March 2007 (has links)
No tratamento reabilitador oral as restaurações provisórias são de suma importância. A resistência e a longevidade dos materiais utilizados em sua execução são críticas, principalmente em tratamentos prolongados e em espaços desdentados extensos. O objetivo deste trabalho foi avaliar a resistência e o modo de fratura de espécimes que simularam uma prótese fixa de três elementos variando o comprimento do cantilever (7, 14 e 21mm), confeccionadas em resina acrílica poli(metilmetacrilato) (PMMA) autopolimerizável, com e sem reforço em seu interior, construídos sobre componentes para implantes. Os reforços utilizados foram: fibras de vidro (Fibrante® - Ângelus®, Londrina, PR, Brasil) e fibras de poli(aramida) (Kevlar® - Du Pont®, USA). Os grupos foram constituídos de 10 espécimes cada, incluindo um grupo controle, sem reforço. Os espécimes foram submetidos à carga compressiva até a fratura. A análise dos resultados (ANOVA, p < 0,05), para o teste de resistência, mostrou não haver diferença estatística entre os grupos com respeito ao tipo de reforço, sendo que houve diferença estatística significante no que respeita ao comprimento do cantilever. Quando o comprimento do cantilever foi de 7mm todos os grupos apresentaram os valores médios de resistência a fratura, em N, significativamente maiores que os apresentados pelos grupos com 14 e 21mm de comprimento. Em relação ao modo de fratura os grupos reforçados apresentaram fraturas mais favoráveis ao reparo, tendo sido do tipo Parcial. / In the oral rehabilitator treatment, the provisory restorations have extremely importance. The resistance and durability of materials used in the execution are critical, especially in extended treatments and in vast toothless spaces. The goal of this work was to demonstrate the resistance and the types of fracture of specimens that simulate a fixed prosthesis of three elements changing the extension of cantilever (7, 14 e 21mm), made of acrylic resin polymethylmethacrylate (PMMA) autopolymer, with and without reinforcement in its interior, built over implant components. The reinforcements used were: fiberglass (Fibrante® - Angelus®, Londrina, PR, Brazil) and poliaramid fiber (Kevlar® - Du Pont®, USA). The groups have 10 specimens each, including a group of control, without reinforcement. The specimens were submitted to a compressor charge until its fracture. The analysis of results (ANOVA, p < 0,05) for the test of resistance, showed that there is no statistic difference between the groups regarding the type of reinforcement; however, there is a significant statistic difference regarding the cantilever extension. When the extension of cantilever was 7mm, all groups showed medium values of resistance to fractures, in N, significant more than the showed by the groups with 14 and 21mm of extension. In relation with the types of fracture, the reinforcement groups show fractures more favorable to be repaired, even when they were partially fractured.

Page generated in 0.1465 seconds