Spelling suggestions: "subject:"dentin bonding"" "subject:"cotentin bonding""
111 |
Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-outTawil, Rosalyn Chidiak 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
|
112 |
Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strengthMorais, Renata Costa de 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
|
113 |
Estudo in vitro do uso de vitrocerâmica bioativa em dentina afetada por cárie natural ou artificial: análise da resistência de união de compósitos / In vitro study of the use of bioactive glass ceramic in affected dentin by natural and artificial caries: analysis of composites\'s bond strengthRenata Costa de Morais 21 January 2015 (has links)
O objetivo deste estudo in vitro foi avaliar a influência da aplicação de vitrocerâmica bioativa na resistência de união de sistemas adesivos em dentina afetada por cárie, natural ou artificial, comparativamente à dentina hígida. Cento e vinte molares humanos, 80 hígidos e 40 cariados, foram selecionados, sendo que 40 dentes hígidos foram submetidos à formação de cárie artificial por ciclagem de pH. Após a planificação das superfícies oclusais, os dentes foram separados em quatro grupos (n=10), segundo o tipo de sistema adesivo (convencional Adper Single Bond ou autocondicionante AdheSE) e tratamento do substrato: Grupo 1 - condicionamento ácido, lavagem e secagem + Biosilicato + sistema adesivo; Grupo 2 - idem ao Grupo 1, sem Biosilicato; Grupo 3 - sistema adesivo autocondicionante + Biosilicato; Grupo 4 - idem ao Grupo 3, sem Biosilicato. Após os tratamentos, os dentes foram restaurados com compósito (Opallis - FGM). Os dentes foram armazenados em água, a 37ºC, por seis meses e, em seguida, seccionados, perpendicularmente à interface adesiva, produzindo palitos de 0,9 mm2 de espessura. As amostras foram fixadas à Máquina de Ensaios Mecânicos (EMIC DL 2000 - 0,5 mm/min) e submetidas ao ensaio de microtração até a fratura. Após os ensaios, as fraturas foram observadas em microscópio digital (Keyence) e o modo de fratura da interface adesiva foi avaliado em microscopia eletrônica de varredura (JSM 5410, Sony). Os valores de Resistência de União (RU) foram submetidos à análise estatística (2-way ANOVA, Bonferroni, p<0,05) e verificou-se que, para os dentes hígidos, G1 apresentou os melhores valores de RU, com diferença estatística (p<0,05) em relação aos demais grupos, seguido de G3 e G2, que não apresentaram diferença (p>0,05) entre si. Os menores valores de RU para esse substrato ocorreram para G4, diferente (p<0,05) em relação aos demais grupos. Depois do substrato hígido, os melhores resultados de RU ocorreram para dentes cariados artificialmente, em níveis semelhantes (p>0,05) entre todos os grupos, com exceção para G2. Para o substrato cariado, não houve diferença significante (p>0,05) entre os grupos estudados. Em comparação aos demais substratos, grupos em que houve aplicação de Biosilicato apresentaram maior RU (p<0,05) quando comparados aos grupos não tratados. Nos grupos em que não houve aplicação de Biosilicato, a RU foi maior (p<0,05) para dentes hígidos que utilizaram sistema adesivo convencional. Para os demais substratos, não houve diferença significante (p>0,05). Não houve diferença significante (p>0,05) na RU em G4, independente do substrato utilizado. A análise do padrão de fratura mostrou predomínio de fraturas adesivas em todos os substratos e seus respectivos grupos. Conclui-se que a associação do sistema adesivo convencional e Biosilicato proporcionou os maiores valores de RU dente/adesivo. / The aim of this in vitro study was to evaluate, by means of microtensile test, the influence of bioactive glass ceramics application in the bond strength of adhesive systems with prior acid etching and natural or artificial caries-affected dentin compared to sound dentin. One hundred and twenty extracted human molars, 80 sound and 40 decayed, were selected, and 40 sound teeth were subjected to artificial caries formation by pH cycling. After occlusal surfacess regularization, teeth were divided into four groups (n = 10): Group 1 - etching, rinsing and drying + Biosilicate + adhesive system; Group 2 - same procedure as Group 1, without Biosilicate; Group 3 - self-etching adhesive system + Biosilicate; Group 4 - same procedure as Group 3, without Biosilicate. After all treatments, teeth were restored with composite (Opallis - FGM). Then, teeth were stored in water at 37°C for six months and sectioned perpendicular to the bonding interface, producing sticks 0.9mm2 thickness. All samples were fixed into a testing machine (EMIC DL 2000 to 0.5 mm/min) and submitted to microtensile bond strength test. The fractures were observed in digital microscope (Keyence) and the fracture pattern was analyzed by scanning electron microscopy (JSM 5410, Sony). The tensile bond strength values (TBS) (2-way ANOVA, Bonferroni, p<.05) were: for sound teeth, G1 showed the best TBS values with statistical difference (p<.05) compared to the other groups, followed by G2 and G3, which showed no significant difference (p>.05) among themselves. The smaller TBS occurred for G4, with significant difference (p<.05) compared to the other groups. Following sound substrate, the second best TBS results occurred for teeth with artificial caries-dentin, at similar levels (p>.05) between all groups, except for G2. For the decayed teeth, there was no significant difference (p>.05) between groups. Groups in which Biosilicate was applied had a higher TBS (p <.05) when compared to untreated groups, which TBS was higher (p <.05) for the sound teeth group on which conventional adhesive system was used. There was no significant difference for the other substrates (p>.05). Regardless the substrate used, there were no significant differences (p>.05) in G4. The fracture pattern analysis showed predominance of adhesive fractures in all groups. It was concluded that the combination of conventional adhesive system and Biosilicate provided the greatest TBS between tooth and adhesive.
|
114 |
AVALIAÇÃO DA INFLUÊNCIA DA CICLAGEM TÉRMICA E MECÂNICA NA EFETIVIDADE DA INTERFACE ADESIVASánchez-ayala, Alfonso 31 January 2008 (has links)
Made available in DSpace on 2017-07-24T19:21:56Z (GMT). No. of bitstreams: 1
Alfonso Sanchez-Ayala.pdf: 4109673 bytes, checksum: f08284c2e1c48354c9d9e417e1b9484e (MD5)
Previous issue date: 2008-01-31 / The aim of this study was to evaluate in vitro the adhesive effectiveness in class V cavities using four different adhesive systems, being submit to thermocycling and occlusal load cycling. The cavities had a dimension of 3x2x1.8 mm3 and were made on amelo-cement junction on buccal and lingual of 80 human premolars (n=160). The used adhesive systems were Adper Single Bond 2, AdheSE, Adper Prompt LPop
and One Coat 7.0. The used composite was Synergy® D6. The adhesive and photopolymerization (600 mW/cm2) proceedings were made conventionally and following the manufacturer recommendations. The specimens were divided in 4 groups (n=40) according to adhesive system used. Each group was divided in 4 subgroups (n=10) according to applycated stress (thermocycling, occlusal load cycling and thermocycling+occlusal load cycling). Each subgroup included 1 control group without stressing. The thermocycling was made using 500 cycles, with 5-55 C, dwell time of 15 seg and transfer time of 5 seg. The occlusal load cycling was made
applying a force of 40-70 N during 50000 cycles with 2 Hz of frequency. Later, the specimens were impermeabilited and immersed in tracer agent of 50 % silver nitrate solution by 2 hours. Finally, the specimens were prepared for adhesive effectiveness evaluation through optic microscopy 40X (marginal microleakage occurrence) and scanning electronic microscopy 1000X (gaps formation). The tracer agent
microleakage was measured qualitative (score) and quantitatively . The gap width was measured on 3 points of center of axial wall. The Kruskal-Wallis and post-hoc de Dunn, and ANOVA two-way and post-hoc Bonferroni tests were used on statistic analysis. Despite of few differences found in used adhesive system performance, the tendency could be observed to the increase of the marginal
microleakage in the submitted groups specifically to thermocycling. On the other hand, the axial gaps formation presented progressively higher width in the submitted
groups to thermocycling, occlusal load cycling and thermocycling+occlusal load cycling. It was concluded that the used adhesive system presented similar adhesive
effectiveness when were submitted to thermal and mechanical stress. / A proposição deste estudo foi avaliar in vitro a efetividade adesiva em cavidades de classe V utilizando quatro diferentes sistemas adesivos, sendo submetidas a termociclagem e carga cíclica oclusal. As cavidades tiveram uma dimensão de
3x2x1.8 mm3 e foram realizadas na união amelo-cementária em vestibular e lingual de 80 pré-molares humanos (n=160). Os sistemas adesivos empregados foram Adper Single Bond 2, AdheSE, Adper Prompt L-Pop e One Coat 7.0. A
resina composta utilizada foi Synergy D6. Os procedimentos de adesão e fotopolomerização (600 mW/cm2) foram realizados convencionalmente e seguindo as recomendações do fabricante. Os espécimes foram divididos em 4 grupos (n=40) segundo o tipo sistema adesivo utilizado. Cada grupo foi dividido em 4 subgrupos (n=10) segundo o tipo de estresse aplicado (termociclagem, carga cíclica oclusal e termociclagem+carga cíclica oclusal). Cada subgrupo incluiu 1 grupo controle sem estresse. A termociclagem foi realizada utilizando 500 ciclos a 5-55 C, 15 seg de tempo de permanência em cada temperatura e 5 seg de tempo de transferência. A carga cíclica oclusal foi realizada aplicando uma força de 40-70 N durante 50000 ciclos com freqüência de 2 Hz. Posteriormente, os espécimes foram impermeabilizados e imersos em agente traçador de solução a 50 de nitrato de
prata por 2 horas. Finalmente, os espécimes foram preparados para a avaliação da efetividade adesiva por meio de microscopia óptica 40X (ocorrência de microinfiltração marginal) e microscopia eletrônica de varredura 1000x (formação de fendas). A microinfiltração do agente traçador foi mensurada qualitativa (escore) e quantitativamente . A largura das fendas foi medida (μm) em 3 pontos do centro
da parede axial. Os testes de Kruskal-Wallis e post-hoc de Dunn, e ANOVA two-way e post-hoc Bonferroni foram utilizados na análise estatística. Apesar das poucas
diferenças significativas encontradas no desempenho dos sistemas adesivos utilizados, pôde-se observar a tendência ao aumento da microinfiltração marginal nos grupos submetidos especificamente a termociclagem. Por outro lado, a
formação de fendas axiais apresentaram progressivamente maior largura nos grupos submetidos a termociclagem, carga cíclica e termociclagem+carga cíclica. Concluise que os sistemas adesivos avaliados apresentaram efetividade adesiva similar quando foram submetidos a estresse térmico e mecânico.
|
115 |
EFEITO DE AGENTES DESSENSIBILIZANTES INCORPORADOS AO ADESIVO NO TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA CERVICAL – ESTUDO IN VITRO E IN VIVO / EFEITO DE AGENTES DESSENSIBILIZANTES INCORPORADOS AO ADESIVO NO TRATAMENTO DA HIPERSENSIBILIDADE DENTINÁRIA CERVICAL – ESTUDO IN VITRO E IN VIVO / Effect of desensitizing agents incorporated into the adhesive in the treatment of cervical dentinal hypersensitivity – In vitro and in vivo study / Effect of desensitizing agents incorporated into the adhesive in the treatment of cervical dentinal hypersensitivity – In vitro and in vivo studyZardo, Ligia Nadal 24 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:02Z (GMT). No. of bitstreams: 1
Ligia Zardo.pdf: 3241924 bytes, checksum: 551ba34ed43ba3f5c10b208bb4902ff8 (MD5)
Previous issue date: 2016-02-24 / The dentin hypersensitivity (DH), characterized by discomfort caused by pain, is a common medical condition that requires the professional challenge in choosing appropriate therapy. From this perspective the present study was structured in three stages. The first consisted in the review of the literature available in PubMed, Scielo, Bireme, Cochrane, in order to discuss etiology and prevalence of cervical dentin hypersensitivity, pain mechanism theory and those adopted therapeutic procedures and their effectiveness. The second consisted of an in vitro study to evaluate the physical and chemical characteristics and the potential obliteration of dentinal tubules by desensitizing agents incorporated into the Ambar adhesive. For that were used 72 samples from 36 bovine teeth divided into 6 groups: ambar + SrCl2 group, ambar + NaF group, ambar + SnF2 group, ambar + KNO3 group, ambar + K2C204 group and ambar group. The specimens were prepared for hydraulic conductance test or dentin permeability (n = 30), Scanning Electron Microscopy (SEM) (n = 18), Spectroscopy Micro Raman (n = 12), and energy dispersive spectroscopy (EDS) (n = 12). Data were analyzed with analysis of variance (ANOVA) of one criterion and the significance level was 5%. A reduction in dentin permeability in the treated groups, but no significant differences seen between the groups (p = 0.134). By Micro Raman was possible to observe the behavior of the molecules of chemical compounds of desensitizing salts embedded in the adhesive remained adhered to dentin surface. In the SEM, to dentin surface completely covered and sealed with adhesive and the presence of the desensitizing salts, because the EDS spectrum revealed the presence of NaF and KNO3 clusters dispersed in the adhesive layer. It is concluded from this study that the occlusive agents NaF, SnF2, SrCl2, KNO3, K2C2O4 remained incorporated into the dentin adhesive, although clusters in the adhesive layer, the group was able to obliterate the tubules and reduce dentin permeability. The third stage aimed to identify the desensitizing effect of therapies and monitor the longevity of the effects of desensitizing agents on dentin hypersensitivity. Evaluated desensitizing therapies were: group 1: Ambar + NaF, group 2: Ambar + KNO3; group 3: Low level laser therapy; group 4: Led; group 5: Clinpro XT and group 6: Ambar adhesive. The radomizaded clinical trial, parallel-type, blind placebo-controlled included the participation of 60 patients, with an eligible tooth, causing pain quantified by Verbal Scale of 4 points (VRS) and Numerical Scale of 101 points (NRS 101) after tactile and thermal stimuli immediately after the procedure, 24 hours, 7, 15, 30, 90 and 180 days after the completion of the procedures. The dependent variable intensity of pain against the tactile stimulation (probe) and thermal (water) was analyzed for each trial using the non-parametric test Kruscal- Wallis. In periods when there was a statistically significant difference, the comparison of peer groups was made utilizando- the Mann-Whitney test. The ionomer sealant Clinpro XT was more effective in the immediate reduction of DH, and maintained its long-term effect. The NaF + adhesive and KNO 3 + adhesive groups were effective in the treatment of DH and responded better to treatment than just the Ambar adhesive. At the end of the six-month evaluation, all evaluated desensitizing agents were effective in reducing pain resulting from tooth sensitivity. / A hipersensibilidade dentinária (HD), caracterizada pelo desconforto causado por dores, é uma situação clínica frequente que impõe ao profissional um desafio na escolha de uma terapia adequada. Nessa perspectiva o presente estudo foi estruturado em três etapas. A primeira constituiu-se na revisão da literatura disponível nas bases Pubmed, Scielo, Bireme, Cochrane, visando discutir etiologia e prevalência da hipersensibilidade dentinária cervical, teoria de mecanismo da dor bem como as condutas terapêuticas adotadas e a eficácia das mesmas. A segunda constituiu-se de um estudo in vitro para avaliar as características físico-químicas e o potencial de obliteração dos túbulos dentinários por agentes dessensibilizantes incorporados ao adesivo Ambar. Para tanto foram utilizadas 72 amostras provenientes de 36 dentes bovinos divididos em 6 grupos experimentais: grupo ambar + SrCl2, grupo ambar + NaF, grupo ambar + SnF2, grupo ambar + KNO3, grupo ambar + K2C204 e grupo ambar. Os espécimes foram preparados para o teste de condutância hidráulica ou permeabilidade dentinária (n=30), Microscopia Eletrônica de Varredura (MEV)(n=18), Espectroscopia Micro Raman (n=12), e Espectroscopia de Energia Dispersiva (EDS)(n=12). Os dados foram analisados com Análise de Variância (ANOVA) de um critério e o nível de significância adotado foi de 5%. Houve redução da permeabilidade dentinária nos grupos tratados, porém sem diferenças consideradas significativas entre os grupos (p= 0,134). Através do Micro Raman foi possível observar o comportamento das moléculas dos compostos químicos dos sais dessensibilizantes incorporados no adesivo que permaneceram aderidos a superfície dentinária. No MEV observou-se a superfície dentinária totalmente recoberta e selada com adesivo e a presença dos sais dessensibilizantes, já o espectro do EDS revelou a presença de aglomerados de NaF e KNO3 dispersos na camada de adesivo. Conclui-se com este estudo que os agentes oclusivos NaF, SnF2, SrCl2, KNO3 e K2C2O4 permaneceram incorporados ao adesivo dentinário e que apesar de aglomerados na camada do adesivo, o conjunto foi capaz de obliterar os túbulos e reduzir a permeabilidade dentinária. A terceira etapa visou identificar in vivo o efeito dessensibilizante das terapias e acompanhar a longevidade dos efeitos do agente dessensibilizante sobre a hipersensibilidade dentinária. As terapias dessensibilizantes avaliadas foram: grupo 1: Ambar + NaF, grupo 2: Ambar + KNO3; grupo 3: Laser de baixa intensidade; grupo 4: Led, grupo 5: Clinpro XT e grupo 6: adesivo Ambar. O ensaio clínico radomizado, cego do tipo paralelo controlado por placebo contou com a participação de 60 pacientes, com um dente elegível, sendo a dor quantificada através da Escala Verbal de 4 pontos (VRS) e Escala Numérica de 101 pontos (NRS 101) após estímulos tátil e térmico, imediatamente após a realização do procedimento, 24 horas, 7, 15, 30, 90 e 180 dias após a conclusão dos procedimentos. A variável dependente intensidade de dor frente ao estímulo tátil (sonda) e térmico (água) foi analisada para cada período experimental utilizando-se o teste não paramétrico de Kruscal-Wallis. Nos períodos em que houve diferença estatisticamente significante, a comparação dos pares de grupos foi feita utilizando- se o teste de Mann-Whitney (p< 0.05). O selante ionomérico Clinpro XT mostrou-se mais efetivo na redução imediata da HD, e manteve seu efeito a longo prazo.
|
116 |
Avaliação da dureza e módulo de elasticidade da interface de união resina – dentina utilizando a técnica de nanoindentação / Assessment of hardness and elastic modulus of resin-dentin bonding area using the nanoindentation techniqueHigashi, Cristian 28 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1
Cristian Higashi.pdf: 1616679 bytes, checksum: a243cd9970614325c2c06ab7c7f592d1 (MD5)
Previous issue date: 2008-02-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the hardness and elastic modulus of resin-dentin bonding area formed by an ethanol/water-based (Adper TM Single Bond 2 [SB]) and
an acetone-based system (One Step Plus [OS]), under different moisture conditions and application methods. On 24 human molars, a flat superficial dentin surface was
exposed by wet abrasion. Two coats of SB or OS adhesive were applied on either a dry (D) or rewetted surface (W), under active (AA) or inactive (IA) application. After
polymerization of the adhesives (600 mW/cm2/20 s), composite build-ups were constructed incrementally and specimens were stored in water (24 h). They were cross-sectioned perpendicular to the resin-dentin interface to obtain slices of 1.5 mm thickness that were embedded and polished before the test. Nanoindentations were made on composite resin, adhesive system, hybrid layer and dentin regions. The results of hardness and elastic modulus (GPa) of adhesive system and hybrid layer were analyzed by a three-way ANOVA and Tukey’s multiple comparison tests
(α=0.05). The mean and standard deviation of hardness and elastic modulus values of composite resin were (1.02 ± 0.07) and (14.94 ± 0.67) respectively. In dentin, the hardness was (0.69 ± 0.10) and the elastic modulus (17.94 ± 1.84). In the adhesive layer, the highest hardness (0.38 ± 0.06) and elastic modulus (6.93 ± 0.93) of SB were obtained in W group. In this same area, the elastic modulus of OS (5.91 ± 1.12)
was lowest in AA group. In the hybrid layer, the hardness of both adhesive systems was highest in AA group, however statistically significant just for OS (0.51 ± 0.2). In D
group the highest hardness (0.47 ± 0.24) and elastic modulus (10.98 ± 4.65) of hybrid layer were obtained with AA. It was concluded that the active application of both adhesives in dry dentin resulted in higher hardness and elastic modulus values
in the hybrid layer and the moisture increased hardness and elastic modulus values of Adper TM Single Bond 2 in the adhesive layer. / O objetivo deste trabalho foi avaliar a dureza e módulo de elasticidade da interface de união resina-dentina formado por adesivos convencionais de 2 passos à base de água/etanol (Adper TM Single Bond 2 [SB]) e à base de acetona (One Step Plus [OS]), variando a umidade dentinária e forma de aplicação dos mesmos. 24 terceiros molares humanos foram lixados para a obtenção de uma superfície dentinária plana.
Duas gotas do adesivo SB ou OS foram aplicadas de forma ativa (AA) ou inativa (AI) sobre uma dentina seca (S) ou reumedecida (U). Após a fotopolimerização dos adesivos (600 mW/cm2 / 20 s) os dentes foram restaurados incrementalmente e
armazenados em água destilada por 24 h. Cortes perpendiculares à interface de união foram realizados para obtenção de fatias de aproximadamente 1,5 mm de
espessura, que foram embutidas e polidas previamente ao teste. Nanoindentações foram realizadas nas regiões da resina composta, sistema adesivo, camada híbrida e dentina. Os valores de dureza e módulo de elasticidade (GPa) do sistema adesivo e camada híbrida foram submetidos a uma análise de variância de 3 fatores de medidas repetidas e ao teste de comparações múltiplas de Tukey (α=0,05). A média e desvio padrão dos valores de dureza e módulo de elasticidade da resina composta (GPa) foram (1,02 ± 0,07) e (14,94 ± 0,67), respectivamente. Na dentina, a dureza foi (0,69 ± 0,10) e o módulo de elasticidade (17,94 ± 1,84). Na camada de adesivo,
os maiores valores de dureza (0,38 ± 0,06) e módulo de elasticidade (6,93 ± 0,93) do SB foram obtidos no grupo U. Nesta mesma região, o módulo de elasticidade do OS (5,91 ± 1,12) foi menor para o grupo AA. Na região da camada híbrida, a dureza de ambos os sistemas adesivos foi maior no grupo AA, porém significativamente somente para o OS (0,51 ± 0,2). No grupo S os maiores valores de dureza (0,47 ± 0,24) e módulo de elasticidade (10,98 ± 4,65) da camada híbrida foram obtidos com AA. Concluiu-se que a aplicação ativa de ambos os sistemas adesivos em substrato dentinário seco resultou nos maiores valores de dureza e módulo de elasticidade na região da camada híbrida e a umidade dentinária influenciou positivamente nos valores de dureza e módulo de elasticidade do sistema adesivo Adper TM Single Bond 2 na região da camada de adesivo.
|
117 |
Efeito do armazenamento em água na resistencia de União de diferenets abordagens de adesão a dentina / Effects of water storage on resin-dentin bond strengths formed by different bonding approachesMartins, Gislaine Cristine 21 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:09Z (GMT). No. of bitstreams: 1
Gislaine Cristine Martins.pdf: 4206631 bytes, checksum: c89ea8320c5c7cd1115382f7f0e02b50 (MD5)
Previous issue date: 2008-02-21 / The purpose of this study was to evaluate the effects of water storage on resindentin bond strengths [μTBS] formed by different adhesive bonding approaches. A flat superficial dentin surface the 24 human third molars were exposed and polished to create a standardized smear layer. The teeth were randomly distributed into four different: total-etch 3 step (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE -
SBMP), and total-etch 2 step (Adper™ Single Bond 2, 3M ESPE - SB); self-etch 2 step (AdheSE, Ivoclar/Vivadent - AD); and self-etch 1 step (Adper™ Prompt™ LPop ™, 3M ESPE - LP). Following the adhesive application (n=6), resin composite crowns were incrementally placed (Filtek™ Supreme XT - 3M ESPE) in order to obtain bonded sticks, with a cross-sectioned area of about 0,8 mm2. The bonded sticks were randomly divided and assigned to be tested immediately [IM] (n=30) or after 6 months of water storage [6M](n=30). Two-way ANOVA and Tukey’s test showed that none of the adhesives showed degradation after 6 months, except SB,
which was the one that achieved the highest μTBS either in the immediate time (49.13 MPa) and after 6 months (40.27 MPa). LP showed the lowest μTBS in both periods of evaluation (18.35 and 18.34 MPa). AD and SBMP showed intermediate performance. But the SB showed lower μTBS significantly after storage anyway showed high results. Conclusion: Although a significant degradation was only
observed for SB, this was the adhesive that showed the highest μTBS after 6M of water storage. It seems that the microtensile test is not sensitive to detect degradation for adhesives with low immediate μTBS. / Este estudo objetivou avaliar o efeito do armazenamento em água na resistência de união [μTBS] de diferentes abordagens de adesão à dentina. As superfícies oclusais de 24 terceiros molares hígidos foram cortadas, planificadas e, a smear
layer padronizada. Os dentes foram divididos aleatoriamente em 4 grupos de acordo com a abordagem de união, ou seja, convencionais, de 3 passos (Adper™ Scotchbond™ Multi-Purpose, 3M ESPE - SBMP) e, de 2 passos (Adper™ Single
Bond 2, 3M ESPE -SB); autocondicionantes, de 2 passos (AdheSE, Ivoclar/Vivadent - AD) e, de 1 passo (Adper™ Prompt™ L-Pop™, 3M ESPE - LP). Após o procedimento adesivo (n=6) os dentes foram restaurados pela técnica
incremental com resina composta Filtek™ Supreme XT (3M ESPE). Obteve-se 240 espécimes em forma de palitos com área aproximada de 0,8 mm2. Dos espécimes obtidos para cada grupo (n=60), metade foi submetido ao teste de resistência de união imediato [IM] (n=30) e, a outra metade foi armazenada em água para realização do teste após 6 meses de armazenamento [6M](n=30). A ANOVA 2 fatores e o pós-teste de Tukey mostraram que não ocorreu degradação após 6M, exceto para o SB, ainda assim, a maior média da resistência de união IM e 6M foi do SB (49.13 e 40.27 MPa). O LP mostrou as menores médias nos dois períodos de avaliação (18.35 e 18.34 MPa). O AD e o SBMP apresentaram desempenho intermediário. Entretanto, o SB apresentou redução significativa da resistência de união após 6M, apesar disso, obteve os melhores resultados. Concluiu-se que
embora ocorreu uma degradação significativa para o SB, este sistema foi o que apresentou maior μTBS após 6 meses de armazenamento em água. O teste de microtração não foi sensível para detectar a degradação dos sistemas adesivos
com valores mais baixos de μTBS.
|
118 |
EFEITO DA INCLUSÃO DE PARTÍCULAS DE CARGA NA RADIOPACIDADE E EM PROPRIEDADES DE SISTEMAS ADESIVOS EXPERIMENTAIS / Effects of of filler addition to experimental adhesives on radiopacity and propertiesMartins, Gislaine Cristine 13 November 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:25Z (GMT). No. of bitstreams: 1
Gislaine Cristine Martins.pdf: 4074240 bytes, checksum: e09201e7bd1d75eac883e17325cc0c46 (MD5)
Previous issue date: 2012-11-13 / The aim of this study was to evaluate the radiopacity, ultimate tensile strength (UTS), microhardness (KHN), degree of conversion (DC), water sorption (WS), solubility (SO), microtensile bond strength (μTBS) and of experimental dental
adhesives with increased addition of barium-borosilicate zirconia nanoparticles or glass microparticles. Methods: Ten experimental adhesive systems with different concentrations of zirconia nanoparticles [0(EX0), 15(EX15), 25(EX25), 35(EX35) and 50%(EX50) and barium-borosilicate oxide microparticles [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] were formulated based on the adhesive system Ambar (FGM).
The adhesive Adper Single BondTM 2 (SB, 3M ESPE) was used as commercial reference. For the radiopacity (n=5), KHN (n=5), WS (n=10) and SO (n=10) tests, adhesive specimens were constructed using a stainless steel mold (5.0 mm in diameter
and 1.0 mm in deep), while for UTS (n=5), a hourglass shape metallic matrix (10 mm long, 2 mm wide, and 1 mm deep with cross-sectional area of 0.8 mm2) was employed.The FTIR spectra of uncured and cured specimens of adhesives were used to determine the DC of the materials. For μTBS, adhesives were applied to flat dentin surfaces of third molars (n=7). Resin composite buildups were constructed and sectioned to obtain resin-dentin bonded sticks to tested immediately (IM) or after 6
months (6M) of water storage. Data were submitted to a one-way ANOVA and Tukey´s test (α=0.05). Results: All experimental bonding adhesives showed radiopacity similar
to enamel. Only R60 showed higher UTS than the other materials. The experimental adhesives showed higher KHN values when compared to the commercial SB. In general, the DC of the experimental solutions was not affected by filler addition and was statistically higher than SB. Although filler addition did not affect WS, it generally reduced the SO. Most of the experimental adhesives showed lower WS and SO than
SB. Conclusions: Both the addition of nanoparticles as microparticles were able to confer radiopacity to adhesives experimental, and adding load influence on the properties tested. In general, it can be said that the best performance was for the addition of microparticles in a concentration of 30%. / Objetivo: Este estudo objetivou avaliar a radiopacidade, resistência máxima à tração,(RMT), microdureza (KHN), grau de conversão (GC), sorção de água (SA),solubilidade (SO), resistência de união (μTBS) de sistemas adesivos experimentais
pela adição de nanopartículas de zircônia ou micropartículas de vidro de bárioborosilicato. Material e métodos: Dez sistemas adesivos experimentais com diferentes concentrações de nanopartículas de zircônia [0(EX0), 15(EX15), 25(EX25),
35(EX35) e 50%(EX50) ou com micropartículas de óxido de bário-borosilicato [0(R0), 30(R30), 40(R40), 50(R50) e 60%(R60)] foram formulados tendo como base o sistema
adesivo Ambar (FGM). O sistema adesivo Adper Single BondTM 2 (SB, 3M ESPE) foi utilizado como referência comercial. Foram confeccionados espécimes de adesivo para os testes de radiopacidade (n=5), KHN (n=5), SA (n=10) e SO (n=10) utilizando matriz metálica com 5,0 mm de diâmetro e 1,0 mm de profundidade e, para a RMT (n=5) uma matriz metálica com 10 mm de comprimento, 2 mm de largura, 1 mm de profundidade e, área de sessão transversal de 0,8 mm2. Os espectros FTIR foram obtidos de espécimes não polimerizados e polimerizados dos adesivos para determinar o GC dos materiais. Para μTBS, aplicou-se os adesivos na superfície de dentina de dentes molares humanos (n=7). Os dentes foram reconstruídos com resina composta e cortados para obtenção de espécimes em forma de palitos que foram testados imediatamente (IM) ou após 6 meses de armazenamento em água (6M). Os dados foram submetidos a ANOVA e pós-teste de Tukey´s (α=0,05). Resultados:Todos os sistemas adesivos experimentais mostraram radiopacidade semelhante a do esmalte dental. Apenas o R60 mostrou valores de RMT mais elevado que os outros materiais. Os sistemas adesivos experimentais apresentaram valores mais altos de dureza Knoop quando comparado ao SB. Em geral, o GC dos adesivos experimentais
não foi afetado pela adição de partículas e, significantemente superior ao SB. A maioria dos adesivos experimentais mostraram menor SA e SO que o SB.Conclusões: Tanto a adição de nanopartículas quanto de micropartículas foi capaz de conferir radiopacidade aos adesivos experimentais e, a adição de carga influenciou nas propriedades testadas. De modo geral, pode-se dizer que o melhor desempenho foi para a adição de micropartículas na concentração de 30%.
|
119 |
Efeito da técnica úmida simplificada de adesão com etanol na cimentação intraradicular de pinos de fibra / Push-out bond strength and SEM evaluation of new bonding approach into the root canalCarvalho, Carlos Augusto Ramos de 28 June 2011 (has links)
Este estudo avaliou a resistência ao deslocamento vertical push-out de pinos de fibra de vidro cimentados à dentina intra-radicular utilizando uma resina fluida padrão como agente cimentante em combinação com um adesivo dentinário experimental e um adesivo disponível comercialmente. 20 pré-molares unirradiculares humanos foram previamente extraídos e tratados endodonticamente. Os espécimes foram divididos em quatro estratégias de união a dentina: Grupo 1 com adesivo experimental com etanol na proporção em volume 1:1 (resina/etanol) e Grupo 2 com adesivo experimental com etanol na proporção em volume 1:2(resina/etanol); adesivos experimentais aplicados de acordo com a técnica úmida de adesão simplificada com etanol, Grupo 3: One-Step Plus aplicado de acordo com a técnica úmida de adesão simplificada com etanol; Grupo 4: One-Step Plus aplicado seguindo as instruções do fabricante. Os espécimes foram seccionados em fatias de 1 mm de espessura e apos o teste push-out foi realizado. Espécimes representativos foram selecionados para exame ultra-estrutural. Não houve diferença estatística na resistência ao deslocamento push-out entre as estratégias testadas de adesão (p> 0,05). O padrão predominante de fratura foi entre os pinos de fibra e o agente cimentante. A partir deste estudo devemos considerar como promissora a técnica com etanol utilizada na cimentação de pinos no canal radicular devido aos possíveis benefícios das resinas altamente hidrófobas. Mais estudos são necessários para validar o uso da técnica úmida de adesão simplificada com etanol quando cimentados pinos de fibra. / This study evaluated the push-out bond strength of glass fiber posts adhesively bonded to intraradicular dentin using a standard unfilled resin as luting agent in combination with an experimental and a commercially available adhesive. Twenty extracted single-rooted human teeth were endodontically treated. Specimens were assigned to 4 dentin bonding strategies: Group 1 (co-monomers to ethanol on ratio 1:1) and Group 2 (co-monomers to ethanol on ratio 1:2): Experimental adhesives applied in accordance with the simplified ethanol-wet bonding technique; Group 3: One-Step Plus (OSP) applied in accordance with the simplified ethanol-wet bonding technique; Group 4: OSP applied following manufacturers instructions. Bonded specimens were sectioned in 1-mm-thick slices and the push-out test was performed. Representative specimens were selected for ultrastructural examination. No statistical differences in push-out bond strength were found among the tested bonding strategies (p>0.05). The major failure pattern was between the post and the luting cement. From this study the ethanol technique should be considered as a promising approach in the luting of fiber posts into the root canal due to the possible benefits of highly hydrophobic resins. Further studies are needed to validate the use of the ethanol-wet bonding technique when luting a fiber post.
|
120 |
"Influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos" / Thermal, mechanical load and pH cycling influence on adhesive systems bond strength to primary dentin.Rocha, Rachel de Oliveira 16 December 2004 (has links)
Nesta pesquisa foi realizada a avaliação da influência das ciclagens térmica, mecânica e de pH na resistência de união de sistemas adesivos à dentina de dentes decíduos. Para tal, cavidades oclusais foram preparadas em 80 molares decíduos e restauradas com os sistemas adesivos Single Bond e Clearfil SE Bond e resina composta Z100. Os dentes restaurados com cada um dos sistemas adesivos foram divididos em oito grupos (n= 5), de acordo com as condições de tratamento: ciclagem térmica (2000 ciclos, 5°C e 55°C), ciclagem de pH (10 ciclos, 8 horas de imersão em solução desmineralizadora e 16 em solução remineralizadora), ciclagem mecânica (100.000 ciclos, 8 kg), térmica/pH, térmica/mecânica, pH/mecânica e térmica/pH/mecânica, além do grupo controle. Os dentes foram seccionados perpendicularmente à interface de união e foram obtidos espécimes com área de superfície aderida com cerca de 0,8 mm 2 . Os espécimes foram submetidos ao teste de microtração e à análise do padrão de fratura em microscopia eletrônica de varredura. Os valores obtidos, expressos em MPa, foram submetidos à Análise de Variância (p < 0,05). Não foram encontradas diferenças estatísticas significantes na comparação entre os sistemas adesivos avaliados nem para os grupos submetidos à aplicação dos estresses térmico, mecânico e térmico/pH. Os demais grupos apresentaram valores de resistência de união inferiores àqueles obtidos pelo grupo controle (p < 0,05) Fraturas do tipo adesiva/mista foram as mais prevalentes (95,9%). A resistência de união dos sistemas adesivos avaliados é negativamente influenciada pela aplicação combinada das tensões com naturezas distintas. / The influence of thermal, mechanical load and pH cycling on adhesive systems bond strength to primary dentin was evaluated. Occlusal cavities in 80 primary molars were prepared with diamond bur and restored with Single Bond and Clearfil SE Bond adhesive systems and Z100 composite. Teeth restored with each adhesive system were shared into eight groups according treatment condition: thermal cycling (2000 cycle, 5°C and 55°C), pH cycling (10 cycles, demineralization solution immersion to 8 hours and 16 hours in remineralization solution), mechanical load cycling (100.000 cycles, 8kg), thermal/pH, thermal/mechanical load, pH/mechanical load and thermal/pH/mechanical load, besides control groups. The teeth were transversally sectioned in two axis rendering 0,8mm 2 stick shaped specimen. Sticks were then submitted to microtensile bond testing with a crosshead speed of 1mm/min. Fracture analysis was performed by scanning electron microscopy. Bond strength means expressed in MPa were submitted to two-wav ANOVA (p<0.05). No statistically significant differences were found between the adhesive systems nor to thermal, mechanical load and thermal/pH stresses groups. Lower bond strength values were found to other groups compared to control (p<0.05). Adhesive/mixed failures were prevalent (95.9%). Bond strengths of evaluated adhesive systems were negatively influenced by distinct tension application.
|
Page generated in 0.1002 seconds