• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 437
  • 135
  • 21
  • 18
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 640
  • 365
  • 209
  • 194
  • 184
  • 163
  • 113
  • 104
  • 98
  • 96
  • 87
  • 85
  • 83
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável

Gonçalves, Andréa [UNESP] 04 April 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-04-04Bitstream added on 2014-06-13T20:06:12Z : No. of bitstreams: 1 goncalves_ar_dr_arafo.pdf: 1974874 bytes, checksum: cb90cfb07e456ba101c0f7c18597c3d6 (MD5) / Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros... / This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below)
382

Influência da qualidade das próteses totais na prevalência de sinais e sintomas de disfunção temporomandibular

Ribeiro, Renato de Aguiar [UNESP] 25 June 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2004-06-25Bitstream added on 2014-06-13T19:24:14Z : No. of bitstreams: 1 ribeiro_ra_dr_arafo.pdf: 762199 bytes, checksum: 5940dcea4937e50fc38fed81681be9c8 (MD5) / Foi avaliado o efeito da qualidade técnica das próteses totais (PTs) na incidência de sinais e sintomas de disfunção temporomandibular (DTM) em pacientes portadores de PTs bi-maxilares. Para a realização deste trabalho, foi aplicado um questionário a 154 pacientes contendo os dados pessoais, o histórico das próteses, o índice anamnésico para DTM e o índice de qualidade de prótese, além do exame físico específico para o diagnóstico de sinais da DTM. Considerando-se a metodologia empregada e a população estudada, pôde-se concluir que a qualidade das PTs não influenciou na presença de sinais e sintomas de DTM. / The aim of the current study was to evaluate the effect of the technical quality of dentures in the incidence of temporomandibular dysfunction (TMD) signs and symptoms in 154 patients wearing complete upper and lower dentures. For the accomplishment of this work a questionnaire was applied containing personal data, the report of the prostheses, anamnestic index to DTM, quality of the dentures index and clinical examination. Through this work, it could be concluded that the quality of the prosthesis not interfered in the incidence of TMD signs and symptoms.
383

Movimentação dos dentes artificiais em próteses totais com diferentes profundidades de palato

Vedovatto, Eduardo [UNESP] 25 May 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-05-25Bitstream added on 2014-06-13T19:24:19Z : No. of bitstreams: 1 vedovatto_e_dr_araca.pdf: 365938 bytes, checksum: bd1dd616abe7c6a4bce474ab109acd1f (MD5) / Demonstração do problema: alterações oclusais sempre ocorrem durante o processamento de próteses totais, entretanto, o deslocamento do dente no sentido ocluso-cervical e sua relação com a profundidade do palato ainda não foi totalmente evidenciada. Objetivos: esse estudo investigou a movimentação dos segundos molares superiores em próteses totais processadas com resina acrílica, com diferentes profundidades de palato e com diferentes materiais de inclusão. Métodos: vinte e oito próteses totais superiores idênticas foram confeccionadas sobre o modelo com palato raso e vinte e oito próteses sobre o modelo com palato profundo. Essas próteses foram divididas em quatro grupos com 14 unidades de acordo com o tipo de palato e o tipo de material de inclusão (gesso ou silicone). Foram demarcados pontos na face distal dos segundos molares e no modelo como referência para a mensuração do deslocamento dos dentes. O deslocamento vertical, horizontal e angular foi verificado através das imagens das próteses com o programa AutoCad em dois momentos: antes da inclusão em mufla e depois da demuflagem (sem a separação do modelo). Os valores foram submetidos ao tratamento estatístico de Kolmogorov- Smirnov e ANOVA com o Tukey e Fisher post hoc test a 5% de significância. Resultados: Os resultados não mostraram diferença estatística significante entre os grupos nos deslocamentos angular (p=0,674) e horizontal (p=0,856). Entretanto, no sentido cervico-oclusal, foi observada diferença entre os grupos (p=0,012) apontando maiores alterações para aqueles cuja inclusão foi realizada com o silicone (E3=0,047 e E2=0,044 cm)em relação ao gesso (E1 = 0,027 e C= 0,026cm). Os grupos com diferentes profundidades de palato não apresentaram diferença estatística significante entre si. Conclusão: esse estudo pôde concluir que o tipo de palato... / Statment of the problem: occlusal changes always occur during the complete dentures, however, the cervical-occlusal displacement of the tooth and its relationship with the plate depth has not yet been well clarified. Purpose: This study investigated the movement of the second molars in complete dentures processed with different palate depths and different materials for inclusion. Methods: Twenty-eight complete maxillary dentures were made on cast with shallow palate and twenty-eight on the cast with deep palate. These grafts were divided into four groups with 14 units according to the type of palate and the type of material for inclusion (gypsum or silicone). Points were marked on the distal face of second molars and in the model for measuring the displacement of the teeth. The vertical displacement, horizontal and angular was verified by the images of the prosthesis with the AutoCad program on two occasions: before inclusion and after deflasking (without the separation of the cast). The values were submitted to statistical Kolmogorov-Smirnov test and ANOVA with Tukey's and Fisher's post hoc test at 5% significance. Results: The results showed no statistically significant difference between groups in the angular displacement (p = 0674) and horizontal (p = 0856). However, the cervical-occlusal direction (vertical displacement), difference was observed between the groups (p = 0012) indicating major changes to those whose inclusion was performed with silicone (E3 = 0047 and E2 = 0044cm) on gypsum (E1 = 0027 and C = 0026cm). The groups with different depths of the palate showed no statistically significant difference between them. Conclusion: This study could conclude that the type of palate did not influence the movement of the second molars, as the method of inclusion of a significant influence on the vertical displacement of the teeth. Clinical... (Complete abstract click electronic access below)
384

Efetividade da irradiação por micro-ondas e da terapia fotodinâmica na inativação de micro-organismos presentes em próteses totais: estudo clínico

Ribeiro, Daniela Garcia [UNESP] 17 July 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-07-17Bitstream added on 2014-06-13T19:45:03Z : No. of bitstreams: 1 ribeiro_dg_dr_arafo.pdf: 1509746 bytes, checksum: 0af0faf81589be8924a39b7a2c3f5b64 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses removíveis estão em contato direto com os tecidos bucais, saliva e sangue e, ao serem removidas da cavidade bucal do paciente, podem estar contaminadas com micro-organismos patogênicos. Esses micro-organismos podem ser transmitidos aos técnicos de laboratório por contato direto ou pelos aerossóis produzidos durante o desgaste ou o polimento de próteses contaminadas. Neste caso, os micro-organismos podem ser disseminados pelo ambiente, desencadeando infecção cruzada. Assim, para prevenir a contaminação cruzada, todas as próteses devem ser desinfetadas ao serem enviadas ao laboratório e ao retornarem ao consultório. Com base nessas considerações, o presente estudo avaliou a efetividade clínica da irradiação por micro-ondas e da terapia fotodinâmica (PDT) para desinfecção de próteses totais superiores. Para os procedimentos de irradiação por micro-ondas, amostras de biofilme das próteses foram coletadas de 30 pacientes, os quais foram divididos aleatoriamente em dois grupos experimentais com 15 indivíduos cada: Grupo 1 - as próteses foram expostas às micro-ondas durante 3 minutos (650 W), Grupo 2 - as próteses foram expostas às micro-ondas durante 2 minutos (650 W). Para os tratamentos com PDT, amostras de biofilme das próteses foram coletadas de 60 pacientes, os quais foram divididos aleatoriamente em quatro grupos experimentais (n = 15 cada): Grupos I e II - as próteses foram borrifadas com 50 mg/L e 100 mg/L do Photogem® em suspensão, respectivamente; Grupos III e IV - as próteses foram tratadas com 50 mg/L e 100 mg/L de Photogem® em gel, respectivamente. Após 30 minutos de pré-irradiação, todas as 60 próteses foram expostas à luz de LED azul com potência de 37,5 J/cm2 (26 minutos). Amostras das próteses foram obtidas utilizando-se swab estéril antes (nas superfícies do lado esquerdo) e após (nas superfícies do lado direito)... / Prosthetic appliances that have been in contact with oral tissues, saliva and blood can be contaminated with pathogenic microorganisms when they are removed from the patient’s mouth. These microorganisms can be transmitted to laboratory staff through direct contact with the infected denture or from aerosols that will be formed when the surfaces are ground or polished. In this case, microorganisms with varying degrees of virulence can be spread and disseminated into the air, leading to cross-infection. In order to prevent microbial cross-contamination among denture patients, all dental prostheses must be disinfected on entering and again on leaving the laboratory. Therefore, this investigation evaluated the clinical effectiveness of microwave irradiation and photodynamic therapy (PDT) on the inactivation of microorganisms present on complete dentures. For microwave irradiation procedures, biofilm samples were collected from dentures of 30 patients, who were randomly divided into two experimental groups of 15 subjects each: Group 1 - patients had their maxillary denture microwaved for 3 minutes (650 W); Group 2 - patients had their maxillary denture microwaved for 2 minutes (650 W). For PDT treatments, biofilm samples were collected from dentures of 60 patients, who were randomly divided into four experimental groups (n = 15 each): Groups I and II - patients had their maxillary denture sprayed with 50 mg/L and 100 mg/L of Photogem® suspension, respectively; Groups III and IV - patients had their maxillary denture treated with 50 mg/L and 100 mg/L of Photogem® gel, respectively. After 30 minutes of pre-irradiation, all sixty dentures were exposure to blue LED light at 37.5 J/cm2 (26 minutes). Denture samples were taken with sterile cotton swabs, before (left side surfaces) and after (right side surfaces) microwave irradiation and PDT procedures. All microbial material was diluted... (Complete abstract click electronic access below)
385

Avaliação da precisão de aquisição de dados nos Sistemas CAD/CAM: desadaptação marginal horizontal

Lopes, Leonardo Ferreira de Toledo Piza [UNESP] 23 February 2015 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:29Z (GMT). No. of bitstreams: 0 Previous issue date: 2015-02-23. Added 1 bitstream(s) on 2015-06-18T12:48:45Z : No. of bitstreams: 1 000831388.pdf: 562171 bytes, checksum: e080c07a229e0894fa23757920f53d4c (MD5) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal horizontal de infraestruturas de próteses fixas confeccionadas pelo sistema CAD-CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Foram confeccionados 50 corpos de prova divididos em 5 grupos, sendo eles, Convencional (Ni-Cr); GI: iTero; GII: CerecBluecam/fresadora industrial; GIII: 3S; GIV: CerecBluecam/ fresadora Sirona, todos com n=10. Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal horizontal, esta dividida em positiva para sobre-contorno e negativa para subcontorno. Resultados: A análise intra-examinador revelou não haver diferença estatística entre os dois períodos de análise (t pareado=0.019; p=0.985). Em relação as desadaptações de sobre-contorno (valores positivos) podemos analisar que o grupo controle (Convencional) apresentou estatisticamente (p <0.001) menores valores de desadaptação (82 μm) quando comparado com o grupo CAD/CAM (144 μm). Ao comparar o sistema intra/extra-oral pode-se observar que o grupo intra-oral (iTero) apresentou melhores resultados, sendo essa diferença estatisticamente significante (p <0.001) que o extra-oral (3s). Já avaliando a diferença entre um sistema aberto com um fechado foi observado que o sistema aberto apresentou estatisticamente menor desadaptação (p<0.001). Quando avaliou-se a quebra de um sistema fechado (Cerec BlueCam) para sua fresagem a nível industrial notou-se que há desvantagens em tal procedimento, pois houve estatisticamente maiores desadaptações no grupo da quebra do sistema (p<0.001). Em contra partida nenhuma diferença estatisticamente significante foi encontrada em todas as análises quando se comparou desadaptação por sub contorno. Significância: Avaliando a discrepância... / Objective: The aim of this study was to evaluate the horizontal marginal fit of frameworks produced by CAD/CAM systems with 3 different data acquisition. Material and Methods: We fabricated 50 frameworks divided into 5 groups, Conventional (Ni- Cr); GI: iTero; GII: CerecBluecam/industrial milling; GIII: 3S; GIV: CerecBluecam/Sirona, all with n = 10. We numbered the specimens and analyzed them randomly. Results: Intra-observer analisys indicated no statistically significant difference (paired t-test=0.019; p=0.985). In relation to the overextended horizontal marginal discrepancy (Positive Values) can analyze that the Control group (Conventional) had significantly (p < 0.001) minor discrepancy values (82 μm) when compared to the CAD / CAM group (144 μm). When comparing the systems intra/extra oral can be appreciated that the intra oral group (Itero) presented statistically best results when comparing(p < 0.001) that the extra oral ( 3s ). Evaluating the difference between the open system with closed was observed that the open system had statistically smaller misfit (p < 0.001). Evaluating the broke of a closed system (Cerec Bluecam) your industrial milling had statistically (p < 0.001) worse adaptation when compared to the laboratorial milling. About the under extended marginal discrepancy, in all analysis there was not found statistically significant difference. Significance: Assessing the horizontal marginal discrepancy was possible to note that in relation to the overextended the control group had statistically better results than the CAD/CAM systems, however the Cerec Bluecam system by sirona milling had better results than all CAD/CAM system and also the control group. There was no difference between the under extended misfit and all analysis
386

Análise através do método dos elementos finitos das tensões desenvolvidas no reborbo alveolar sob as próteses totais com três diferentes conceitos oclusais

Ferreira, Luciano Pedrin Carvalho [UNESP] 19 April 2011 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:33Z (GMT). No. of bitstreams: 0 Previous issue date: 2011-04-19Bitstream added on 2014-12-02T11:21:14Z : No. of bitstreams: 1 000676004.pdf: 904634 bytes, checksum: 03b638ed685399c100b20ec02e2eef12 (MD5) / A distribuição das tensões nas estruturas de suporte de tensões decorrentes de forças oclusais aplicadas a próteses totais confeccionadas com diferentes esquemas oclusais não são conhecidos. O objetivo deste estudo foi desenvolver, através do método de elementos finitos bidimensional (MEF-2D), uma analise comparativa e qualitativa das tensões geradas nas estruturas de suporte na região de primeiro molar inferior direito de próteses totais confeccionadas com: (1) Oclusão convencional (OC); (2) Oclusão lingualizada (OL) e, (3) Oclusão monoplana (OP). Os padrões de distribuição de tensões foram observados em quatro condições de reabsorção óssea do rebordo alveolar: (1) alto e convexo; (2) lamina de faca; (3) baixo e convexo e, (4) involuido. Dois materiais de confecção de dentes artificiais foram considerados: resina acrílica e porcelana. Modelos digitais bidimensionais para a aplicação do MEF-2D foram desenvolvidos para as condições propostas. Uma carga vertical de 50N foi aplicada na superfície oclusal do primeiro molar inferior direito. Através do software GID (International Center for Numerical Methods in Engineering, Barcelona, Espanha) foram geradas imagens gráficas de stress (tensões de Von Mises) e de compressão (tensões verticais) nas estruturas de suporte. Neste estudo concluiu-se que: 1. Todos os esquemas oclusais estudados transmitiram stress e compressão para as estruturas de suporte; 2. 15 OC gerou um padrão de distribuição de stress e de compressão em faixas horizontalizadas, enquanto que OL e OP em faixas verticalizadas; 3. OC apresentou um padrão de distribuição de intensidade de stress e de compressão que aumenta da crista do rebordo alveolar para o osso esponjoso, enquanto que OL e OP um padrão que aumenta de vestibular para lingual; 4. Os diferentes níveis de reabsorção do rebordo não interferiram nas intensidades ou padrões... / The strain distribution patterns in the alveolar residual ridge as a consequence of occlusal loads applied in complete dentures constructed with different occlusal schemes are not known. The aim of this study was to develop a comparative and qualitative analysis of the strains generated in the right first molar region of the supporting structures of a mandibular complete denture using the two-dimentional Finite Element Analysis (FEA-2D). Coronal section two-dimensional models were developed reflecting mandibular complete dentures constructed with three different schemes of occlusion, namely conventional (CO), Lingualized (LO) and monoplane (PO). The models also had variations in the contour of the supporting structures, representing four conditions of residual ridge resorption: (1) high, well rounded; (2) knife edge; (3) low, well rounded, and (4) depressed. Two materials of artificial teeth were considered: acrylic resin and porcelain. A vertical load of 50 N was applied onto the occlusal surface of the mandibular right first molar. The software GID (International Center for Numerical Methods in Engineering, Barcelona, Spain) generated images of Von Mises (stress) and vertical (compression or tensile) strains in the FEA-2D models. Within the limitations of this study the following conclusions were drawn: (1) Stress and compression were observed in the supporting structures with all of the studied occlusal schemes; (2) The distribution of stress and compression with CO dentures generated patterns of intensity with the appearance of horizontal layers and, with LO and PO dentures with the appearance of vertical layers; (3) With CO dentures the intensity of stress and compression increased progressively from the crest of the residual ridge to the alveolar bone and, with LO and PO dentures from the buccal to the lingual slope of the ridge; (4) With all of the studied occlusal schemes, neither the...
387

Determinação da resistência à flexão de ligas odontológicas, utilizadas em prótese parcial fixa e prótese sobre implante, soldadas por brasagem e a laser

Dinato, José Cícero [UNESP] 17 June 1999 (has links) (PDF)
Made available in DSpace on 2015-01-26T13:21:25Z (GMT). No. of bitstreams: 0 Previous issue date: 1999-06-17Bitstream added on 2015-01-26T13:30:29Z : No. of bitstreams: 1 000126007.pdf: 2963801 bytes, checksum: 120f344cee7d077baf10fbd42aa2abf3 (MD5) / O objetivo deste trabalho foi determinar a resistência à flexão de sessenta corpos-de-prova cilíndricos, obtidos a partir de quatro ligas metálicas utilizadas em prótese parcial fixa e prótese sobre implante, disponíveis no mercado brasileiro (Co-span 13.5, Stabilor G, Deva 4 e Palliag M) medindo 25 mm de comprimento e 3 mm de diâmetro. Cinco corpos-de-prova de cada liga foram fundidos em monobloco, cinco soldados por brasagem e cinco a laser Nd-YAG, Dessa forma, obtiveram-se 15 corpos-de-prova para cada liga metálica, divididos em três grupos. No grupo I, os corpos-de-prova foram fundidos em monobloco; no grupo 2, soldados por brasagem; no grupo 3, soldados a laser. Após a conclusão dos corpos-de-prova, os três grupos foram submetidos a um ensaio de resistência flexural, em uma máquina de testes lnstron. O ensaio consistiu em submeter os corpos-de-prova a uma carga ao seu centro, com as suas extremidades apoiadas em dois cilindros separados por uma distância de 20 mm, de modo que sofressem a ação e reação da carga em apenas três pontos. A velocidade de aplicação da carga foi de 0,5 mm/min, com uma célula de carga de 500 kg. Os resultados numéricos obtidos foram submetidos à Análise de Variância e ao teste de Tukey, ao nível de 5% de probabilidade. Em vista dos resultados obtidos, conclui-se que o maior valor numérico da resistência flexural foi encontrado para a liga Co-span 13.5, seguido do Deva 4, para os grupos de soldagem a laser e monobloco. O material Palliag M apresentou valores estatisticamente semelhantes para os três grupos. A liga Stabilor G apresentou os melhores resultados no método por brasagem / The mechanic properties of brazed joints compared with castings performed in monoblocks have been exhaustingly evaluated. The use of laser in Dentistry opened a new and promising field to study this type of fusion. The purpose of this study was to determine the flexural resistance of four types of metal alloys used in fixed partial prosthodontics (Co-span 13.5, Stabilor G, Deva 4 and Palliag M). Fifteen test specimens with 3 mm diameter and 25mm length were obtained by casting for each alloy, and divided in three groups (monoblocks, brazing and laser welding), totaling sixty cylindrical specimens. The specimens were submitted to GLP/O2 torch welding and Nd-YAG laser welding performed with a specific laser equipment (Laser 2002, Dentaurum, Germany). The results were compared with tests performed in monoblocks of these same materials. To determine the flexural resistance, an universal testing machine (Instrom, model 4301), with a 500 Kg maximum capacity was used. The results were statistically analyzed using an ANOVA and Tuckey'.s test in a 5% degree of probability. The results showed that the highest numeric value of flexural resistance was found with the Co-Span alloy, followed by Deva 4, for both laser welding and monoblock groups. Palliag M showed statistically similar values for the laser welding, brazing and monoblock groups, whereas Stabilor G presented its highest values in brazing
388

Avaliação da resistência flexural de materiais restauradores provisórios resinosos /

Machado, Carolina Ellen Spínola January 2018 (has links)
Orientador: Andréa Abi Rached Dantas / Resumo: O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / Abstract: The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces. / Mestre
389

Avaliação da resistência flexural de materiais restauradores provisórios resinosos / Evaluation of the flexural strength of temporary resin restorative materials

Machado, Carolina Ellen Spínola 17 May 2018 (has links)
Submitted by Carolina Ellen Spinola Machado (carolina.machado@unesp.br) on 2018-07-17T17:50:57Z No. of bitstreams: 1 Tese Mestrado Carol Spinola Correção Final.pdf: 1288993 bytes, checksum: 2bda3149606dd9c289679698a83d6cbc (MD5) / Approved for entry into archive by Ana Cristina Jorge null (anacris@fclar.unesp.br) on 2018-07-17T18:28:03Z (GMT) No. of bitstreams: 1 machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5) / Made available in DSpace on 2018-07-17T18:28:03Z (GMT). No. of bitstreams: 1 machado_ces_me_arafo_int.pdf: 1335157 bytes, checksum: c25b86d1526dd6b3333d99b75d0e04b1 (MD5) Previous issue date: 2018-05-17 / O objetivo do estudo foi avaliar a resistência flexural de materiais restauradores resinosos provisórios (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) após a fotopolimerização com sistema de fotoativação LED-laser: Radii-Cal (SDI, São Paulo, SP, BR). A resistência flexural demonstrada pelos materiais restauradores provisórios Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) foi similar (p >0,05) e maior que a demonstrada pelos materiais restauradores BiFix (Voco) e Clip F (Voco) (p < 0,05). Por outro lado, a resistência flexural apresentada pelo BiFix e Clip F foi semelhante entre si (p > 0.05). Concluimos assim que os materiais Provi Master F, Systemp e Fill Magic são materiais de melhor escolha quando necessitamos de uma resistência maior às forças oclusais. / The objective of this study was to evaluate the flexural strength of temporary resin restorative materials (Systemp Onlay, Bifix Temp, Provyl Master F, Fill Magic e Clip F) after photopolymerization with LED-laser photoactivation system: : Radii-Cal (SDI, São Paulo, SP, BR). The flexural strength demonstrated by the provisional restorative materials Provi Master F (Wilcos), Systemp (Ivoclair) e Fill Magic (Coltene) was similar (p >0,05) and greater than that demonstrated by restorative materials BiFix (Voco) e Clip F (Voco) (p < 0,05). On the other hand, the flexural strength demonstrated by Be Fil and Clip F were similar among themselves (p > 0.05). We conclude that the materials Provi Master F, Systemp and Fill Magic are materials of better choice when we need a greater resistance to occlusal forces.
390

Avaliação da distorção linear em estruturas métalicas de próteses sobre implantes: fundidas em peça única e em segmentos soldados a laser e através da soldagem convencional (brasagem)

Costa, Elza Maria Valadares da [UNESP] 29 June 2001 (has links) (PDF)
Made available in DSpace on 2018-07-27T18:25:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2001-06-29. Added 1 bitstream(s) on 2018-07-27T18:29:54Z : No. of bitstreams: 1 000138043.pdf: 3009336 bytes, checksum: 4461e732807121379a46347a761b1f11 (MD5) / Próteses sobre implantes osseointegrados requerem critério de fabricação preciso devido a ausência de tecidos periodontais que compensam erros menores de relacionamento. Para tanto, em um arco mandibular edêntulo, construído em aço-cromo, foram fixados cinco análogos de pilares de implante, paralelos entre si, com distância de 10mm medidos de centro a centro. Sobre estes foram parafusados novos cilindros de ouro, com torque de 10 N/cm. Então foram executadas 15 sobre-estruturas metálicas que foram divididas: GC - Adaptação passiva dos cilindros de ouro; GM - monobloco GB - segmentos soldados por brasagem e, GL - segmentos soldados a laser. Observou-se as estruturas parafusadas com parafusos sempre novos sob microscópio de mensuração. A medição foi realizada na vestibular e lingual da interface cilindro/análogo e dados anotados em tabela apropriada. Para o eixo y, a técnica de soldagem a laser (Media=12,41 e Dp=11,12) produziu menos distorção significativamente do que a técnica de brasagem (Media=23,06 e Dp=13,31) seguida pela técnica de monobloco (Media=39,83 e Dp=21,88) p= 0.05. Para o eixo x, somente o grupo Monobloco apresentou diferença significativa para as demais técnicas (Média= 45,66 e Dp=21,56) / Prosthesis above osseointegrated implants requires an accurate criterion of manufacture. So, in an edentulous mandibular arch, constructed with chromium steel, five analogous were fixed, parallels, with distance of 10 mm measured of center to center. Above these gold cylinders were positioned and screwed with a torque of 10 N/m. In the next follow, fifteen over structures were fabricated and divided in tour groups: CG - Passive adaptation of gold cylinders; MG - Monobloc casting; BG - Casting in segments after brasing; LG - Casting in segments after laser welding. The structures were observed with measures microscope and the data noted in specific table. The measures done in two points (left and right) in the buccal and lingual surfaces of the interface of the cylinder/analogous set in the x and y-axis. The statistics analysis (ANOVA) showed significant statistics differences, on y-axis, among groups: LG group was superior to BG and this was superior to MG group and on x-axis only MG was superior to others groups (when we studied distortion.)

Page generated in 0.0934 seconds