• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 437
  • 136
  • 21
  • 18
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 6
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 641
  • 365
  • 209
  • 194
  • 184
  • 163
  • 113
  • 104
  • 98
  • 96
  • 87
  • 85
  • 83
  • 77
  • 74
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
361

Resistência de união e limite de fadiga de nichos confeccionados em resina composta e cimentos à base de ionômero de vidro

Lopes, José Fernando Scarelli [UNESP] 17 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-17Bitstream added on 2014-06-13T18:58:07Z : No. of bitstreams: 1 lopes_jfs_me_arafo.pdf: 1497511 bytes, checksum: 5cff0da20eacc454b65a7066c2aba9f6 (MD5) / O objetivo desta investigação foi determinar a resistência de união e limite de fadiga de nichos confeccionados em resina composta e ionômeros de vidro. Setenta e cinco corpos-de-prova (incisivos mandibulares humanos hígidos) com etiquetas adesivas com perfurações de 3,5mm de diâmetro foram adaptadas sobre a superfície lingual de cada dente. Esta delimitação tinha como objetivo padronizar a área da superfície de esmalte a ser condicionada e, posteriormente, mantida em contato com os materiais restauradores. Para realização dos nichos, matrizes foram realizadas para cada corpo-de-prova onde o material restaurador foi inserido. Os corpos-de-prova foram imersos em água destilada a 37ºC por um período de 30 dias. Para os ensaios de resistência à união, a máquina de testes mecânicos MTS modelo 810 foi calibrada utilizando uma velocidade de deslocamento de 0,5mm/min. Para os testes de limite de fadiga a máquina de testes foi calibrada para submeter cada corpo-de-prova a 10.000 ciclos constantes, com uma freqüência de 5 Hz, amplitude inicial de 0,5 mm e velocidade de rampa inicial de 100N/s. Os valores originais do experimento foram convertidos de N para MPa em função da área da base do nicho (circular) previamente calculada. Os corpos-de-prova após a fratura foram avaliados através de microscopia eletrônica de varredura com aumento de 500 vezes. A médias de resistência à união e limite de fadiga foram comparadas estatisticamente usando o teste de Análise de Variância a um Critério. Nos teste de cisalhamento, a resina composta Z-100 produziu maior valor de resistência de união (12,25 MPa) ao esmalte dentário que o ionômero de vidro convencional Fuji IX (7,21MPa). Não foram observadas diferenças entre os valores do material Fuji II LC (10,29MPa) e os demais materiais. Para todos os materiais, os corpos-de-prova testados por meio de ensaio dinâmico de... / The aim of this study was to determine the bond strength and fatigue limit of rest seats prepared with composite resin and glass ionomer cements. The lingual aspect of seventy-five specimens (intact human mandibular incisors) was delimited by adhesive tags with 3.5-mm diameter perforations. This delimitation aimed at standardizing the area of enamel surface to be etched and later kept in contact with the restorative materials. For preparation of the rest seats, matrixes were obtained for each specimen on which the restorative material was placed. The specimens were immersed in distilled water at 37ºC for a period of 30 days. For the bond strength assays, the mechanical assay machine MTS model 810 was calibrated at a displacement speed of 0.5mm/min. For the fatigue limit tests, the assay machine was calibrated so as to submit each specimen to 10,000 constant cycles, at a 5-Hz frequency with an initial range of 0.5mm and initial sloping speed of 100N/s. The original values of the experiment were converted from N to MPa according to the previously calculated circular area of the base of the rest seat. After fracture, the specimens were evaluated by means of scanning electron microscopy with magnification of 500x. The means of bond strength and fatigue limits were statistically compared through the one-way variance analysis. For the shear resistance test, the composite resin Z-100 yielded a higher value of bond strength (12.25 MPa) to the dental enamel than the conventional glass ionomer cement Fuji IX (7.21MPa). No differences could be found between Fuji II LC (10.29MPa) and the further materials. For all materials, the specimens submitted to dynamic fatigue assay tests yielded lower mean values than those achieved through static shear assays. Regarding the fatigue limit values, all materials presented different behaviors, being that Fuji II LC obtained the higher mean value (6.4MPa), ...(Complete abstract, click electronic access below)
362

Seleção da largura dos dentes ântero-superiores de próteses totais: estudo de quatro métodos fundamentados na posição dos caninos em três grupos raciais da população brasileira

Varjão, Fabiana Mansur [UNESP] 25 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0 Previous issue date: 2003-02-25Bitstream added on 2014-06-13T19:37:34Z : No. of bitstreams: 1 varjao_fm_me_arafo.pdf: 1134180 bytes, checksum: be812a6efba826848a2bdee9ab2eb8c7 (MD5) / O objetivo deste estudo clínico foi avaliar, em três grupos raciais da população brasileira (brancos, pardos e negros) o comportamento de quatro métodos fundamentados na posição dos caninos (largura nasal, comissuras bucais, centro da papila incisiva e margem posterior da papila), utilizados para a seleção da largura dos dentes artificiais anteriores de próteses totais. A amostra constituiu-se de 120 indivíduos dentados entre 18 e 33 anos, de ambos os sexos, divididos em três grupos: Grupo 1 - 40 brancos; Grupo 2 - 40 pardos e Grupo 3 - 40 negros. Em cada indivíduo, foi mensurada a largura nasal, demarcada a posição das comissuras bucais em uma matriz e realizada uma moldagem total superior. No modelo, foram mensuradas a distância intercuspídea dos caninos, a distância em curva entre as distais dos caninos e entre a posição das comissuras transpostas com o auxílio da matriz, a distância da linha intercuspídea dos caninos ao centro da papila incisiva e a distância da linha das distais dos caninos à margem posterior da papila. Os dados foram correlacionados de acordo com os princípios de cada método e comparados em função das raças. Foi também determinado o erro de seleção, em mm, inerente à utilização de cada método. Concluiu-se que: (1) Para os grupos de brancos, pardos e negros a largura nasal e a projeção das comissuras bucais apresentaram baixas correlações, respectivamente, com a distância intercuspídea e com a distância entre as distais de caninos, insuficiente para serem utilizadas como fatores de previsão e, os métodos da papila incisiva não apresentaram as linhas passando pelo centro e pela margem posterior da papila coincidentes, respectivamente, com as pontas de cúspide e com as distais dos caninos. (2) A observação do relacionamento entre o tamanho dos dentes naturais e o tamanho dos dentes artificiais... / The objective of this study was to observe in three races (white, mixed pardo and black) the behavior of four anthropometric methods based on maxillary canines position determination (nose width, mouth width, center of incisive papilla and posterior border of incisive papilla). A total of 120 dentate subjects aged of 18 and 33 years and mixed sex was selected. They were divided in three racial groups: Group 1 - 40 white subjects; Group 2 - 40 mixed pardo subjects and Group 3 - 40 black subjects. The nasal width of each subject was measured and the position of the corners of the mouth was marked on a silicone matrix. An impression was made from the maxillary arch and on the obtained stone cast the following distances were measured: the intercanine distance; the curve distance between the distal of the canines and between the position of the corners of the mouth (using the matrix); the distance from a line passing through the tips of the canines to the center of the incisive papilla; the distance from a line passing through the distal of the canines to the posterior border of the papilla. It were concluded that: (1) For all studied racial groups, the nose width and mouth width showed weak correlation respectively with the intercanine distance and the overall width of the maxillary anteriors, not high enough to be used as predictive factors. Also, the incisive papilla methods showed no coincidence of the center and the posterior border respectively with a line passing through the tips of the canines and a line passing through the distal of the canines. (2) The relationship between natural teeth width and artificial teeth width, as indicated by the studied methods, showed, for all studied racial groups, that the utilization of the nose width method and the...(Complete abstract, click electronic access below)
363

Avaliação da desadaptação e microdureza superficial de quatro resinas acrílicas para base de dentaduras utilizando métodos de polimerização e armazenagem em água

Miessi, Ana Carolina [UNESP] 29 September 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-09-29Bitstream added on 2014-06-13T19:37:36Z : No. of bitstreams: 1 miessi_ac_me_araca.pdf: 741354 bytes, checksum: ba78d27d53c30aac75b9b79cea2cc8e6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste trabalho foi avaliar a desadaptação e a microdureza superficial de quatro tipos de resinas acrílicas para base de dentaduras, em função de período de armazenagem em água de seis meses. Foram confeccionados vinte e cinco conjuntos modelo de gesso-base de resina, utilizando-se quatro resinas acrílicas: QC-20 que foi submetida à polimerização convencional (de acordo com as instruções dos fabricantes) e por energia de microondas (840 W por três minutos), Vipi Cril submetida à polimerização convencional (fabricante), Vipi Wave e Onda Cryl que receberam polimerização por energia de microondas conforme as recomendações dos fabricantes. Após a polimerização, os conjuntos modelo de gesso-base de resina foram seccionados na região posterior correspondente a região de post-dam para a leitura da desadaptação, com auxílio de um microscópio comparador, em três pontos referenciais: crista dos rebordos direito e esquerdo e região mediana do palato. Os conjuntos seccionados foram, então, imersos em água destilada a 35 l 2ºC por período de noventa dias, após o qual uma segunda leitura da desadaptação foi realizada. Imediatamente, os conjuntos modelo-base de resina foram separados e a bases de resina retiradas para a remoção dos excessos grosseiros da borda até o limite estabelecido pelo modelo de gesso. Posteriormente, as bases de resina acrílica foram fixadas nos respectivos modelos com adesivo de presa rápida colocado na região correspondente à crista do rebordo alveolar e uma terceira leitura para analisar a desadaptação, nos pontos referenciais, foi realizada. Após a terceira leitura, os conjuntos ficaram novamente imersos em água destilada a 35 l 2ºC e armazenados em estufa por um período de mais noventa dias, findo o qual uma quarta leitura nos pontos previamente demarcados foi... / The aim of this work was to evaluate the missfitting and the superficial microhardness of four acrylic resins types for dentures base due to storage period in six months water. 25 model sets of resin plaster-base have been confectioned using four acrylic resins: QC-20, which was submitted to the conventional polymerization (in accordance with the manufacturer's instructions) and microwaves energy polymerization (840W for three minutes) and Vipi Wave and Onda Cryl, which have received microwaves energy polymerization also in accordance with the manufacturer's recommendations. After the polymerization process, the model sets of resin plaster-base were parted in the corresponding posterior region, the post-dam region, for the missfitting analysis. This was supported by a comparing microscope in three reference points: right and left crest of ridges and palate's middle region. The parted sets have been, then, immersed in distilled water about 35 to 2°C, for a 90-day period which was followed by a second missfitting analysis. The resin base-model sets were immediately separated and the resin bases were immediately removed to promote the edge coarse excesses' removal until the limit established by the plaster model. Later, the acrylic resin bases were fixed in the respective models with fast stick adhesive, which was placed in the corresponding region to the alveolar crest of ridges. A third analysis to study the missfitting in the reference points was carried through. After the third analysis the sets were immersed again in distilled water about 35 to 2ºC and stored in a stove for a certain period, which exceeded 90 days. As soon as this period was finished, a fourth analysis was carried through in the points previously outlined (180 days total analysis period...(Complete abstract, click electronic address below)
364

Ruídos articulares em pacientes parcialmente desdentados (classe I ou II de Kennedy), antes e após a reposição dental com prótese parcial removível: avaliação através da eletrovibratografia

Baleeiro, Renata Porfíria [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:35:12Z : No. of bitstreams: 1 baleeiro_rp_me_araca.pdf: 915852 bytes, checksum: eda0ee966910bd8f3eec26386a5fc0fa (MD5) / Universidade Estadual Paulista (UNESP) / As alterações no aparelho estomatognático parecem se originar do desequilíbrio ortopédico da mandíbula. Uma das causas desse desequilibro é a ausência do suporte oclusal que poderia conduzir a uma posição côndilo-disco inadequada na fossa mandibular, diminuição da força dos músculos elevadores da mandíbula, lubrificação deficiente. Essas mudanças podem levar ao desalojamento do disco articular e, conseqüentemente, ao aparecimento de vibrações articulares. Dessa forma, este estudo busca identificar e quantificar a presença de vibrações por meio da eletrovibratografia em articulações temporomandibulares de pacientes Classe I e/ou II de Kennedy, no momento da consulta, um ano e dois anos após o tratamento oclusal. Os resultados indicaram que as vibrações articulares foram mais freqüentes no final da abertura e do fechamento bucal. Entretanto, as vibrações diminuíram no primeiro e no segundo ano, sendo que somente após dois anos a redução foi estatisticamente significante. A redução da vibração articular verificada é sugestiva de que o suporte molar evita o desalojamento do disco e permite um fortalecimento muscular. / The alterations in stomatognathic apparatus can be originate by orthopedical disbalance of the jaw. One of the causes of orthopedical disbalance is the absence of the occlusal support that could lead to a inadequate condyle-disk position related to mandibular fossa, weakness of mandibular elevators muscles, and joints temporomandibulars deficient lubrication. These alterations can contribute to displacement of the articular disk and consequently the forthcoming of articular vibrations. This aim of this study is to identify and quantify the presence of vibrations through the electrovibratography in temporomandibular joint of Kennedy class I and/or II patient, at the initial appointment, one year and two years after the occlusal treatment. The results indicated that the articular vibrations were more frequent at the end of the opening and buccal closing. However, the vibrations decreased in the first and second year. After second years the differences were statistically significant. The reduction of the articular vibration verified is suggestive that the support molar avoids the displacement of the disk and it allows a muscular invigoration.
365

Influência do processamento de próteses totais superiores em função da profundidade do palato: análise da movimentação dos dentes artificiais por computação gráfica

Vedovatto, Eduardo [UNESP] 09 December 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-12-09Bitstream added on 2014-06-13T19:37:37Z : No. of bitstreams: 1 vedovatto_e_me_araca.pdf: 3678407 bytes, checksum: 61a0add7350fb3375bfca3d4c3dcaff0 (MD5) / Universidade Estadual Paulista (UNESP) / Em função do relacionamento existente entre a profundidade do palato e as alterações das bases de resina acrílica, esse trabalho investigou a movimentação dos dentes que ocorrem quando próteses totais são processadas com diferentes materiais e técnicas e a relação com o formato do palato. Foram confeccionadas vinte e oito réplicas de próteses totais sobre modelos maxilares com palato raso e vinte e oito réplicas para o palato profundo, idênticas quanto ao enceramento e posicionamento dos dentes. As próteses foram divididas em oito grupos com sete espécimes cada, de acordo com o tipo de resina utilizada, o material utilizado para inclusão em mufla e o tipo de palato. Foram demarcados pontos sobre os dentes que serviram de referência para as mensurações através do software AutoCAD 2005. As mensurações foram realizadas em dois estágios: após o enceramento das próteses e após a demuflagem (não separadas do modelo). Os resultados foram submetidos à análise de variância e as comparações ao teste de Tukey com probabilidade de 5%. Os resultados mostraram que não houve diferença estatisticamente significante entre os grupos estudados, porém quando a análise ocorreu num contexto geral, diferença estatisticamente significativa foi observada para as variáveis, formato de palato e material de inclusão. Baseado nos resultados pode-se concluir que: o formato do palato influencia nas alterações dos dentes artificiais; o palato profundo sofreu alterações dentais significantemente inferiores que o palato raso; as próteses incluídas com silicone apresentaram alterações significantemente superiores às incluídas com gesso; o tipo de resina utilizada não acarretou em alterações estatísticamente significantes entre si; a região posterior das próteses apresentou maiores alterações em relação à região anterior. / About the relationship between the palate depth and the changes in acrylic resins base-plate, this work investigate the teeth movement that occurs when the complete dentures were processed by different materials, techniques and its relation to the palatal form. Twenty eight samples of complete dentures in maxillary cast with shallow palate form and twenty eight with deep palate form were constructed for the study. The samples presented similarities in the artificial teeth position. This prosthesis were divided in eight groups with seven specimens each, in agreement with the resin type for inclusion, the type of material used in the covering and the type of the palate depth. Points were demarcated on the teeth, which served as reference for the measurements of the segments (among the teeth), through software AutoCAD 2005. The measurements are accomplished in two moments: after the waxed and after the desflasking (not descasting). The results were submitted to the analysis of variance and comparisons to the Tukeyþs test with probability of 5%. The results showed no statistical significantly differences between the groups, but when the variables were study in global context difference were observed for the palatal form and covering materials. Based on the results conclude that: the palatal form influence on the changes of teeth position. The deep palate showed alterations significantly inferior that presented for the shallow palate. The silicon used for the covering results in greater alterations in relation to the stone mold. The type of resin not differs in the alterations of teeth position (not significantly). The change of teeth position was greater in the posterior region compares to the anterior region of the prosthesis.
366

Análise da variação da posição relativa dos dentes artificiais no arco dental em função do processamento de próteses totais mandibulares mensurada por computação gráfica

Zaze, Cesar Aurélio [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005Bitstream added on 2014-06-13T18:35:11Z : No. of bitstreams: 1 zaze_ca_me_araca.pdf: 893710 bytes, checksum: 246541052b07b294999b016436174c3a (MD5) / Universidade Estadual Paulista (UNESP) / Este trabalho foi idealizado com o intuito de contribuir para os estudos pertinentes à área da prótese total, e teve como objetivo analisar a alteração da posição relativa dos dentes artificiais em razão do processamento de 40 próteses totais inferiores, obtidas por uma matriz de silicone pré-moldada. Na metodologia, as próteses foram divididas em quatro grupos de 10, que receberam os seguintes tratamentos: Grupo 1 - inclusão em muflas metálicas com muralha de gesso pedra tipo III e polimerização em banho de água quente; Grupo 2 - inclusão em muflas de fibra de vidro com muralha de gesso pedra tipo III e polimerização em microondas; Grupo 3 - inclusão em muflas metálicas com muralha de silicone e polimerização em banho de água quente e Grupo 4 - inclusão em muflas de fibra de vidro com muralha de silicone e polimerização em microondas. Como conclusões, os resultados demonstraram que houve alteração na posição dos dentes artificiais em todas as técnicas de processamento, com o grupo 3 apresentando os melhores resultados seguido dos grupos 4, 2 e 1. / The purpose of this study is to analyze the change in denture tooth position in the fabrication of complete mandibular dentures after different processing techniques. A total of 40 mandibular complete dentures, obtained by a premolded matrix of silicon, were fabricated. There were a total of four groups of complete mandibular dentures. Each group consisted of 10 complete mandibular dentures which were fabricated in the following manner: Group 1 - were processed in a metallic flask using stone plaster type III and polymerized in hot water; Group 2 - were processed in a fiberglass flask using stone plaster type III and polymerized in a microwave; Group 3 - were processed in a metallic flask using silicon and stone plaster type III and polymerized in hot water; Group 4 - were processed in a fiberglass flask using silicon and stone plaster type III and polymerized in a microwave. In conclusion, the results demonstrated that there were alterations in tooth position in all processing techniques. However, Group 3 presented with the least amount of change in tooth positon, followed by Group 4, then Group 2, and finally Group 1 with the most amount of change in tooth position.
367

Estudo comparativo da elevação do ramo superior do articulador, após o processamento, de próteses totais com oclusão lingualizada e com oclusão convencional

Basso, Michael Frederico Manzolli [UNESP] 24 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-24Bitstream added on 2014-06-13T19:58:26Z : No. of bitstreams: 1 basso_mfm_me_arafo.pdf: 801992 bytes, checksum: d8f95bdb865a946a355b011567189536 (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foi objetivo deste estudo realizar experimento laboratorial comparativo da elevação do ramo superior do articulador, após o processamento, entre próteses totais confeccionadas com oclusão balanceada lingualizada e com balanceada oclusão convencional. Para isso, foram confeccionados, pela técnica da prensagem e polimerização em banho de água a 72º C, durante 9 horas, 30 pares de próteses totais padronizados, divididos em dois grupos: Grupo 1 (controle) - próteses com oclusão convencional, as quais apresentavam contatos oclusais cêntricos nas cúspides vestibulares dos dentes posteriores inferiores e palatinas dos dentes posteriores superiores e Grupo 2 (experimental) - próteses com oclusão lingualizada, as quais apresentavam contatos cêntricos somente nas cúspides palatinas dos dentes posteriores superiores. Os registros da dimensão vertical de oclusão foram obtidos em aparelho de mensuração, com relógio comparador micrométrico posicionado sobre ponto específico do ramo superior do articulador, imediatamente antes e após o processamento das próteses. Todas as mensurações foram feitas em triplicata, para obtenção de médias. O aumento médio da dimensão vertical de oclusão, após o processamento, foi de 0,872l0,214mm, para o grupo 1, e de 0,897l0,271mm, para o grupo 2. Realizado o teste t, não houve diferença estatisticamente significativa entre os grupos. Conclui-se que: (1) as próteses totais confeccionadas em oclusão lingualizada tiveram um aumento da dimensão vertical de oclusão no articulador, após processamento laboratorial, semelhante às próteses totais confeccionadas em oclusão convencional; (2) apesar dos dois esquemas oclusais estudados apresentarem aumentos da dimensão vertical de oclusão semelhantes, a oclusão lingualizada geraria ajustes oclusais pós-processamento mais simples, por apresentar menor número de contatos cêntricos... / The aim of this study was to compare articulator opening after processing for complete dentures having balanced lingualized occlusion with complete dentures having balanced conventional occlusion. Thirty sets of standard compression molded complete dentures - maxillary and mandibular - were obtained by polymerization in water bath at 72º C for 9 hours and distributed as follows: Group 1 (control) - complete dentures with conventional occlusion. In this group, the mandibular buccal cusps were occluding in the maxillary central fossae and the maxillary lingual cusps were occluding in the mandibular central fossae; Group 2 (experimental) - complete dentures with lingualized occlusion. In this group, only the maxillary lingual cusps were occluding in the mandibular central fossae. The vertical dimension of occlusion was measured always at the same point of the upper member of articulator. The measurements were recorded with a micrometer, immediately before and after processing of the complete dentures. All measurements were made in triplicate. The mean increase in vertical dimension of occlusion, after processing, was 0,872l0,214 mm, for group 1, and 0,897l0,271 mm, for group 2. A t test was performed and a statiscally significant difference was not found. Conclusions: (1) After processing, complete dentures made with lingualized occlusion showed an increase in vertical dimension of occlusion similar to complete dentures made with conventional occlusion; (2) Despite the two occlusal concepts had leaded to similar increases in the vertical dimension of occlusion, the lingualized occlusion could result in easier occlusal adjustments, after processing, because of the smaller number of centric contacts. Of this point of view, the laboratory working time should be considered by professionals who work in this area.
368

Estudo clínico randomizado do movimento da prótese total superior durante a mastigação em usuários de overdentures mandibulares retidas por um ou dois implantes / Randomized clinical trial of maxillary complete denture movement during chewing on wearers of mandibular overdentures retained by one or two implants

Policastro, Vivian Barnabé [UNESP] 06 April 2016 (has links)
Submitted by Vivian Barnabé Policastro null (vivianbpolicastro@foar.unesp.br) on 2016-05-12T16:12:26Z No. of bitstreams: 1 Dissertação final - Vivian B. Policastro.pdf: 1510147 bytes, checksum: 9f419c0a576b25cc5a8d89d0bb0d04a1 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-16T13:03:00Z (GMT) No. of bitstreams: 1 policastro_vb_me_arafo.pdf: 1510147 bytes, checksum: 9f419c0a576b25cc5a8d89d0bb0d04a1 (MD5) / Made available in DSpace on 2016-05-16T13:03:00Z (GMT). No. of bitstreams: 1 policastro_vb_me_arafo.pdf: 1510147 bytes, checksum: 9f419c0a576b25cc5a8d89d0bb0d04a1 (MD5) Previous issue date: 2016-04-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Overdentures retidas por um implante têm sido apresentadas como uma opção de tratamento para pacientes que apresentam problemas relacionados à retenção e estabilidade de suas próteses totais inferiores, podendo representar uma alternativa à reabilitação com overdentures retidas por dois implantes. O objetivo deste estudo foi avaliar a movimentação da prótese total superior em usuários de overdentures mandibulares retidas por um ou dois implantes durante a mastigação de dois alimentos teste. Vinte e um pacientes usuários de próteses totais bimaxilares novas foram divididos em dois grupos e posteriormente submetidos à instalação de um (G1; n=11) ou dois (G2; n=10) implantes na região anterior da mandíbula. Após 4 meses foram instalados pilares o’rings sobre os implantes e realizou-se a captura das cápsulas e anéis de retenção por meio de alívio e reembasamento das próteses totais inferiores. Um cinesiógráfo foi utilizado para registrar a movimentação da prótese total superior, nos seguintes períodos: antes da cirurgia (baseline), 3, 6 e 12 meses após a ativação dos implantes, durante a mastigação voluntária de dois tipos de alimentos teste, pão e poliéter. O teste de ANOVA de três fatores de medições repetidas mistas seguido pelo teste de Bonferroni foram utilizados na análise dos dados (α=0,05). Para o eixo vertical, houve uma menor intrusão da prótese total superior quando os pacientes apresentavam prótese total convencional inferior (µ=0,60±0,28 mm), em comparação aos períodos 3 meses (µ=0,79±0,40 mm), 6 meses (µ=0,89±0,63 mm) e 12 meses (µ=0,93±0,71 mm) após ativação dos implantes. Ainda, pacientes reabilitados com overdentures retidas por 1 implante obtiveram uma maior intrusão da prótese total convencional superior (µ=0,95±0,55 mm) em comparação com aqueles reabilitados com overdentures mandibulares com 2 implantes (µ=0,65±0,46 mm). Observou-se que houve um deslocamento da prótese total superior em direção inferior apenas quando os pacientes utilizavam PT convencional mandibular (µ=0,23±0,23 mm), sendo que essa deslocamento foi significante apenas em comparação ao período de 12 meses após a ativação dos implantes (µ=0,14±0,25 mm). Para o eixo anteroposterior, observou-se que houve em pacientes reabilitados com 1 implante um maior deslocamento da prótese total superior em direção para anterior no período de 12 meses (µ=0,97±0,77 mm), em comparação ao baseline (µ=0,44±0,33 mm), 3 meses (µ=0,43±0,42 mm) e 6 meses (µ=0,49±0,67 mm). Ainda, no período 12 meses, foi observado que o deslocamento da PT para anterior foi maior nos pacientes reabilitados com 1 implante (µ=0,97±0,77 mm) em comparação aos pacientes reabilitados com 2 implantes (µ=0,26±0,63 mm). Conclui-se que: (1) reabilitação com overdentures mandibulares retidas por um ou dois implantes promove uma maior intrusão da prótese total superior; (2) após substituição de próteses mandibulares convencionais por overdentures, não se observou um deslocamento em direção inferior da prótese total superior; (3) overdentures mandibulares retidas por um implante promoveram uma maior intrusão vertical e movimentação para anterior da prótese total superior; (4) o tipo de alimento não influenciou na movimentação da prótese total superior. / Overdentures retained by one implant have been presented as a treatment option for patients with problems related to retention and stability of their mandibular complete dentures, which may represent an alternative to rehabilitation with overdentures retained by two implants. The objective of this study was to evaluate the movement of the conventional maxillary complete denture among users of overdentures retained by one or two implants during chewing of two food test. Twenty-one patients received new maxillary and mandibular dentures and were divided into two groups and subsequently receive one (G1; n = 11) or two (G2; n = 10) implants in the mandibular arch. After four months, the ball attachments were inserted to the implants and a processed denture reline was made to incorporate the implant retention using retentive elements. A kinesiograph was used to record the maxillary complete denture movement in the following periods: before surgery (baseline), 3, 6 and 12 months after implants retention, during voluntary chewing two types of test foods: bread and polysulphide blocks. Data were analyzed using three-way ANOVA followed by Bonferroni test (α=.05). For the vertical axis, a lower vertical intrusion of the maxillary denture was observed when patients had convencional mandibular complete denture (µ=0,60±0,28 mm), in comparison with 3 months (µ=0,79±0,40 mm), 6 months (µ=0,89±0,63 mm) and 12 months (µ=0,93±0,71 mm) after implants retention. In addition, patients that received overdentures retained by one implant had a higher intrusion of the maxillary denture (µ=0,95±0,55 mm) in comparison with those patients that received overdentures mandibular retained by two implants (µ=0,65±0,46 mm). It was observed that there was a displacement of the maxillary complete denture against the support area only with the patients that used conventional mandibular denture (µ=-0,23±0,23 mm) and this displacement was significant only in comparison with the period of 12 months after implants retention (μ = 0.14 ± 0.25 mm). For the anteroposterior axis, it was observed that there was a higher maxillary denture anterior movement at 12 months (µ=0,97±0,77 mm), in comparison with baseline (µ=0,44±0,33 mm), 3 months (µ=0,43±0,42 mm) and 6 months (µ=0,49±0,67 mm) for patients rehabilitated with one implant. Also, at 12 months, it was observed a higher maxillary denture anterior movement in patients with 1 implant (μ = 0.97 ± 0.77 mm) compared to patients that received two implants (μ = 0.26 ± 0.63 mm). It is concluded that: (1) Overdentures retained by one or two implants produced higher vertical intrusion of the maxillary denture; (2) after replacement of conventional mandibular dentures for overdentures, it was not observed a dislocation of the maxillary denture against the support area; (3) mandibular overdentures retained by one implant promoted higher vertical intrusion and anterior movement of the maxillary complete dentures; (4) the type of test food had no influence on the maxillary complete denture movement.
369

Sistemas CAD/CAM: avaliação da precisão de aquisição de dados

Mello, Caroline Cantieri de [UNESP] 18 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:41Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-18Bitstream added on 2015-03-03T12:06:08Z : No. of bitstreams: 1 000795787.pdf: 571234 bytes, checksum: f635d0ca5e8e957bf53c65ab8998057a (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Objetivo: O objetivo deste estudo foi avaliar a adaptação marginal de infraestruturas de próteses fixas confeccionadas pelo Sistema CAD/CAM com três diferentes sistemas de aquisição de dados. Material e Métodos: Confeccionaram-se 50 corpos de prova; Convencional (Ni-Cr) (n = 10), GI: iTero (n = 10), GII: CerecBluecam/fresadora industrial (n = 10), GIII: 3S (n = 10) e GIV: CerecBlueCam/Sirona (n = 10). Os corpos de prova foram numerados e randomizados, realizou-se análise da desadaptação marginal vertical. Resultados: A análise intra observador indicou que não houve diferença estatisticamente significante (teste t pareado, p = 0.822) no período antes e depois das análises. O sistema convencional (321 ?m) apresentou maior desadaptação quando comparado com o sistema CAD/CAM (89 ?m) (p<0.001). O sistema intra oral (iTero) apresentou menor índice de desadaptação marginal, quando comparado com o sistema extra oral (3S), (p<0.001). O sistema aberto apresentou maior índice de desadaptação marginal (114 ?m) quando comparado com intra oral (iTero), sendo p<0.001. Além disto, no sistema convencional, observou-se que os pré-molares apresentaram índice de desadaptação maior quando comparado (361 ?m) com o molar (283 ?m) (p<0.001), porém no sistema CAD/CAM não houve diferença estatisticamente significante na comparação de dentes pré-molares (93,7 ?m) e molares (84,9 ?m). Significância: O sistema CAD/CAM pode atuar mais favoravelmente, reduzindo o índice de desadaptação marginal, quando comparado com o sistema convencional de confecção de próteses dentárias. O sistema intra oral (iTero) comportou-se melhor quando comparado com os demais sistemas. / Objective: The aim of this study was to evaluate the marginal fit of frameworks produced by CAD/CAM systems with three different data acquisition. Material and Methods: We fabricated 50 frameworks: conventional (Ni-Cr) (n = 10), GI:iTero (n = 10), GII:CerecBluecam/industrial milling (n = 10), GIII:3S (n = 10), and GIV:CerecBlueCam/Sirona (n = 10). We numbered the specimens and analyzed them randomly. Results: Intra-observer analysis indicated no statistically significant difference (paired t-test, p = 0.822) before and after the analysis. The conventional system (321 ?m) showed greater misfit than the CAD/CAM (89 ?m) (p<0.001) system. The intraoral system (iTero) showed a lower rate of marginal misfit than the extra-oral system (3S), (p<0.001). The open system presented a higher marginal discrepancy (114 ?m) than intraoral (iTero), with p<0.001. Moreover, in the conventional system, premolars (361 ?m) showed a higher index of misfit than molars (283 ?m) (p<0.001), but for the CAD/CAM system, there was no statistically significant difference between premolars (93.7 ?m) and molars (84.9 ?m). Significance: The CAD/CAM system can to act more favorably reducing the rate of marginal discrepancy than the conventional impression system of dental prosthesis. The intra oral system (iTero) was better than other systems. / FAPESP: 11/06311-5
370

Avaliação da adaptação marginal de copings cerâmicos obtidos por diferentes métodos de moldagem / Evaluation of the marginal adaptation of ceramic copings obtained by different molding methods

Pinto, Tatiana Saretta Ferreira [UNESP] 13 August 2018 (has links)
Submitted by Tatiana Saretta Ferreira Pinto (tatiorto13@hotmail.com) on 2018-10-11T15:04:44Z No. of bitstreams: 2 tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) tese final para impressão.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-10-16T21:13:07Z (GMT) No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) / Made available in DSpace on 2018-10-16T21:13:07Z (GMT). No. of bitstreams: 1 pinto_tsf_me_sjc.pdf: 1518062 bytes, checksum: f5bc8c4dd9de4a0b0698c8932e0aef20 (MD5) Previous issue date: 2018-08-13 / O objetivo desse estudo foi avaliar a adaptação marginal de copings cerâmicos obtidos pelos métodos de moldagem convencional e escaneamento. Os modelos foram separados em 3 grupos para avaliação e todas as coroas foram confeccionadas sobre um modelo mestre previamente fabricado em CoCr. Grupo 1: Com o auxílio de uma moldeira individual cilíndrica de acrílico foram reproduzidas 10 moldagens com silicona de adição (Panasil) no modelo mestre pela técnica de moldagem dupla e replicados dez modelos físicos em gesso pedra Fuji Rock.Sobre esses modelos foi realizado o enceramento dos copings, confecção dos sprues de cera e sobre eles foi realizada a injeção da cerâmica Grupo 2: foram realizadas 10 moldagens diretas com scanner extraoral (Swing Dental Scanner) no modelo mestre. As imagens foram obtidas através do software Exocad e copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Grupo 3: foram realizadas 10 moldagens diretas com scanner intraoral (CEREC Bluecam) no modelo mestre. As imagens foram obtidas através do software Exocad. Copings em IPS-Emax CAD foram confeccionados em fresadora (Ceramill Motion 2) para posterior sinterização da cerâmica. Os copings de cerâmica não foram cimentados no modelo mestre, apenas posicionados e mantidos com pressão constante de 1,4 a 1,5 kg durante a medição, com a ajuda de um delineador adaptado para esse trabalho, onde oito pontos eletivos foram usados como referência para medir a distância vertical entre a linha de término do modelo mestre e a linha de término dos copings. A margem em cada ponto foi medida 3 vezes com estéreomicroscópio Discovery V20 (ZEISS). A média de desadaptação marginal foi calculada e submetida ao teste de variância de um fator ANOVA com nível de significância de 5% e foram obtidos os seguintes resultados: 66,15µm para o grupo 1; 67,48µm para o grupo 2 e 72,91µm para o grupo 3,verificando assim que esses valores não diferem estatisticamente e todos estão dentro do limite de aceitabilidade clínica / The objective of the study was to evaluate the marginal adaptation of ceramic crowns obtained by conventional molding and scanning methods. The models were separated into 3 groups for evaluation and all the crowns were made on a master model previously manufactured in CoCr. For group 1: With the aid of a single cylindrical acrylic tray the master model was molded 10 times with Panasil in the master model by the technique of double molding and replicated ten physical models in stone gypsum Fuji Rock. On these models was done the waxing of the copings, making the sprues of wax and on them was carried out the injection of the ceramics In group 2, 10 direct impressions were performed with the Swing Dental Scanner (Korea) extra oral scanner in the master model. The images were obtained through the software Exocad (GmbH) and copings in IPS-Emax CAD were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramics. In group 3, 10 direct impressions were performed with the CEREC Bluecam intraoral scanner (Sirona Dental Systems) in the master model. The images were obtained through the Exocad (GmbH) software. IPS-Emax CAD copings were made in the Ceramill Motion 2 (Amanngirrbach) mill for subsequent sintering of the ceramic. Ceramic copings were not cemented in the master model, only positioned and maintained with a constant pressure of 1.4 to 1.5 kg during the measurement, with the aid of an eyeliner adapted for this work, where eight elective points were used as reference to measure the vertical distance between the end line of the master model and the end line of the copings. The margin at each point was measured 3 times with stereo microscope Discovery V20 (ZEISS). The mean was calculated and submitted to the ANOVA variance test "with a significance level of 5% and the following results were obtained: 66.15μm for group 1; 67.48μm for group 2 and 72.91μm for group 3, thus verifying that these values do not differ statistically and all are within the limit of clinical acceptability.

Page generated in 0.0415 seconds