Estudo térmico da excitatriz estática do gerador da usina hidrelétrica derivação do Rio Jordão usando sensores a fibra ótica

Bortolotti, Fernando 13 December 2013 (has links)
Este trabalho tem como objetivo compreender o comportamento térmico da excitatriz estática da Usina Hidrelétrica Derivação do Rio Jordão (UHEDRJ), empregando redes de Bragg em fibra ótica como sensor de temperatura. São apresentados os componentes da excitatriz estática, com foco na ponte retificadora trifásica controlada a tiristores. Com a calibração pôde-se conhecer os erros e incertezas dos sensores, tendo as maiores contribuições de incerteza devidas à dispersão das amostras e ajuste das curvas pelo método dos mínimos quadrados. A instrumentação da excitatriz estática permite que sejam realizados ensaios em diversas condições de operação da unidade geradora: partida da unidade, excitação a vazio, ou seja, com o gerador energizado, mas sem estar conectado ao sistema elétrico; excitada e sincronizada, ou seja, gerador energizado e sincronizado com o sistema elétrico; rampa de carga até a carga nominal e parada da unidade. Os ensaios realizados permitem estimar o comportamento térmico da ponte retificadora, variações de temperatura de cada tiristor no painel e como ocorrem as dissipações térmicas. / This work aims to study the static exciter thermal behavior of the hydroelectric power plant Rio Jordão (UHEDRJ) using fiber Bragg gratings as temperature sensor. The components of the static exciter are presented, with a focus on three-phase thyristor controlled bridge rectifier. The calibration allows knowing the errors and uncertainties of the sensors and the greatest uncertainty contributions due to dispersion of the samples and adjusting the curves by the method of minimun squares. The static exciter instrumentation allows performed the tests in various operating conditions of the generating unit: starting unit, excitation empty (with the generator energized but not connected to the grid); excited and synchronized (energized and synchronized with the power grid), ramp load to rated load and the unit stopped. The tests allow to estimate the thermal behavior of the bridge rectifier, temperature variations of each thyristor in the panel and how occur the thermal dissipation.
22

Transdutor a fibra ótica para análise de biodiesel e misturas BX

Heidemann, Bárbara Rutyna 31 March 2011 (has links)
CNPq / Uma alternativa para as análises tradicionais do biodiesel e misturas BX, como a cromatografia, a espectroscopia e a ressonância magnética nuclear, é a análise por meio de um transdutor de índice de refração a fibra ótica, como uma LPG. Entretanto, como os índices de refração do biodiesel e do óleo diesel são próximos ou maiores do que o índice de refração da casca da fibra na qual a rede se encontra, há uma grande perda de energia para o meio externo, comprometendo a eficiência do sensor. Com o propósito de diminuir o índice de refração do biodiesel, uma substância miscível e de baixo índice de refração, o ciclohexano, foi escolhida para ser misturada a esse biocombustível, assim como à mistura óleo diesel-biodiesel. Os resultados obtidos mostram que o ciclohexano não é reagente com essas substâncias, atuando apenas como solvente. Além disso, as diluições 1:1 e 1:2 (uma parte de mistura BX para uma parte de ciclohexano; uma parte de mistura BX para duas partes de ciclohexano) têm índices de refração menores do que o da casca da fibra, o que faz com que a banda ressonante seja deslocada para menores comprimentos de onda, possibilitando, assim, a detecção por meio da LPG. Após as curvas de calibração serem representadas em gráficos de variação de comprimento de onda (nm) em função da concentração de biodiesel em óleo diesel, BX (% v/v), para as duas diluições, obteve-se, por meio da derivada desta, a sensibilidade. As características metrológicas foram calculadas, levando à obtenção da incerteza expandida, que é de 3,7 % para a diluição 1:1 e de 5,9 % para a diluição 1:2, para um nível de confiança de 95,45 %. / An alternative for the traditional biodiesel and BX blends analysis (X is the biodiesel volumetric concentration in the blend), such as chromatography, spectroscopy and nuclear magnetic resonance, is by means of an optical fiber refractive index transducer, such as an LPG. However, as the biodiesel and diesel refractive index are close or bigger than the fiber cladding index, there is an important loss of power to the surrounding environment, impairing the sensor performance. In order to decrease the refractive index of biodiesel, a miscible and low refractive index substance, cyclohexane, was chosen to blend to this biofuel and also to the biodiesel-diesel blend. The results show that the cyclohexane does not react with biodiesel, acting only as a solvent. Besides, the 1:1 and 1:2 dilution (one part of BX blend and one part of cyclohexane in volume concentration; one part of BX blend and two parts of cyclohexane in volume concentration) have a refractive index lower than the fiber cladding, what shifts the resonant band of the LPG towards lower wavelengths. After representing the calibration curves in graphics of wavelength shift (nm) as function of biodiesel-diesel blend concentration, BX (% v/v), for both dilution, the concentration sensitivity has been obtained. The metrological characteristics were calculated, leading to the expanded uncertainty, which is 3,7 % for the 1:1 dilution and 5,9 % for the 1:2 dilution, for a 95,45 % confidence level.
23

Sensor a fibra óptica para monitoração de mancais de hidrogeradores

Dreyer, Uilian José 23 March 2014 (has links)
CAPES / Este trabalho tem como objetivo desenvolver um sensor a fibra óptica para a monitoração de temperatura em mancais de hidrogeradores de usinas hidrelétricas. Foi apresentado o projeto gráfico, modelagem térmica, processo de montagem e testes realizados. Por tratar-se de uma inovação, é difícil a comparação com outros sensores ópticos desenvolvidos especificamente para monitorar temperatura em mancais de hidro geradores. Inicialmente, foram realizados ensaios preliminares com um protótipo para determinação da dinâmica térmica no interior dos mancais em situações diversas de operação. A partir dessa medição, foi idealizado um sensor óptico que possui duas fibras ópticas, com 3 redes de Bragg gravadas em cada uma delas. Essas redes são encapsuladas por uma haste de alumina coberta com anéis de material com elevada condutividade térmica onde as redes de Bragg se localizam, e baixa condutividade térmica no restante da haste. O procedimento, para calibrar as redes de Bragg do sensor, consistiu em varias a temperatura em degraus de 10°C desde 10°C até 80°C. Cada valor de temperatura permaneceu estável durante 20min, permitindo que o comprimento de onda refletido de cada sensor pudesse ser estimado mediante um histograma. A partir da calibração foram determinados os coeficientes de correlação e o coeficiente de sensibilidade térmica de cada sensor, bem como a incerteza padrão combinada dos mesmos. As incertezas foram divididas em dois tipos, A e B. As incertezas do tipo A, são relativas à dispersão amostral e são determinadas a partir da média, variância e desvio padrão das amostras realizadas durante a calibração. As incertezas do tipo B são obtidas de manuais e certificados de calibração. Foram realizados testes em laboratório com o objetivo de submeter o novo sensor a grandes variações térmicas, entre 15°C e 75°C e checar se as incertezas determinadas correspondiam na prática. Os resultados obtidos apresentam erro máximo de aproximadamente 0,9°C entre o sensor óptico e o sensor de referência PT100. Esse resultado situa-se dentro da faixa de valores de incerteza calculada para os sensores da fibra óptica 1, respectivamente 1,7°C, 1°C e 0,7°C para os sensores 1, 2 e 3. Assim como para a fibra 2, foram observados os valores de incerteza de 0,98°C e 0,71°C respectivamente para as FBG 1, 2 e 3. O desenvolvimento deste sensor possibilita a criação de novos sistemas de monitoração de temperatura ópticos aplicáveis em geradores de grande porte, bem coma interligação destes sistemas visando no futuro o mapeamento térmico total de um gerador utilizando sensoriamento óptico. / This work aims to develop a fiber optic probe for temperature monitoring in bearings of generators hydro power plants. Graphic design, thermal modeling, assembly and testing process is presented. Once it is innovation, it is difficult to compare with other optical transducers developed specifically for monitoring temperature in bearing hydro generators. Initially experiments were performed with a prototype for determination of the thermal dynamics inside the bearings in various operating situations. From this measurement, an optical transducer was designed which was two optical fibers with 3 Bragg gratings recorded in each of them. These gratings are encapsulated by a rod made of alumina and covered with rings of material with good thermal conductivity where the Bragg grating is located, and low thermal conductivity in the remainder of the rod. The procedure for calibrating the Bragg gratings of the transducer consisted of steps of 10°C in the temperature range from 10°C to 80°C. Each temperature value remained stable during 20 min, allowing the mean wavelength reflected from each sensor might be estimated by a histogram. Were determined from the calibration the correlation coefficient and the coefficient of thermal sensitivity of each sensor, and the combined standard uncertainty thereof. The uncertainties were divided into two types: Type A uncertainties are related to the sample dispersion and are determined from the mean, variance and standard deviation of the samples taken during calibration, and type B where uncertainties are obtained from manuals and certificates of calibration. Tests were conducted in laboratory with the aim to submit the new transducer to large temperature variations, ranging between 15°C and 75°C and to check if the uncertainties corresponded in practice. The results presented the maximum error of about 0.9°C between the optical sensor and the reference sensor PT100. This result is within the range of uncertainty values calculated for the fiber optical fiber 2, uncertainty values of 0.98°C, 0.85°C to 0.71°C respectively for the FBG 1, 2 and 3 were observed. The development of this transducer enables the creation of new systems for monitoring temperature optical applicable in generators, as well as the interconnection of these systems to the future the total thermal mapping of a generator using optical sensing. / 5000
24

Monitoração de propriedades mecânicas de polímeros com sensor à rede de Bragg

Lourenço Junior, Ivo de 18 February 2011 (has links)
Este trabalho apresenta um estudo sobre a utilização de redes de Bragg em fibra ótica (FBG), para a monitoração das deformações mecânicas oriundas do processo de secagem de tintas. No intervalo de tempo referente ao processo de secagem, uma fina camada de tinta sofreu uma mudança de estado físico de líquido para sólido, se transformando em um filme contínuo e mecanicamente estável. As deformações mecânicas presentes neste processo foram mensuradas pelo transdutor, demonstrando a real possibilidade das redes de Bragg serem aplicadas para estes fins. Para o acompanhamento temporal das deformações mecânicas no processo de secagem de uma tinta látex, a FBG foi encapsulada com o objetivo de evitar o contato da tinta com a fibra ótica, devido à ineficaz aderência entre ambas, e consequentemente melhorar a aderência da tinta sobre o dispositivo encapsulado. Este processo de encapsulação da FBG permitiu que as deformações mecânicas oriundas do processo de secagem fossem eficientemente transformadas em perturbações mecânicas mensuradas pelo transdutor. O acompanhamento temporal das deformações mecânicas oriundas do processo de secagem também foi investigado com a utilização de tinta diluída. Finalmente, um estudo sobre as deformações mecânicas de uma segunda camada de tinta (duas demãos) é ainda abordado. As redes de Bragg utilizadas neste trabalho foram produzidas e caracterizadas quanto à deformação mecânica longitudinal e temperatura, no Núcleo de Dispositivos Fotônicos da UTFPR. / This work shows results obtained with the use of fiber Bragg grating (FBG) transducer to monitor the drying process of latex paints. When a thin film of wet paint is dried on the substrate surface, the paint film change from a sticky liquid state to a solid state, transforming to a continuous, transparent and mechanically stable film. The mechanical deformations in this process were measured by the FBG sensor head, showing the real possibility of FBG strain sensor application in this area. To monitor the mechanical deformation in the film during the drying process, the FBG was packaged. The FBG packaging has two main functions: allows a better measurement of the paint mechanical deformation inherent to the drying process and also avoids paint poor adhesion to the bare optical fiber. The packaged FBG, showed that this is a promising device to be used for the measurement of stress evolution in paints during the drying time. The mechanical deformation during drying time of diluted latex paint also was investigated. Finally, a study about the mechanical deformation of a second coating application of latex paint was also carried out. The Bragg gratings used in this work were produced in photosensitive fibers by means of a phase-mask interferometric external fabrication technique at Núcleo de Dispositivos Fotônicos laboratories of UTFPR.
25

Estudo térmico da excitatriz estática do gerador da usina hidrelétrica derivação do Rio Jordão usando sensores a fibra ótica

Bortolotti, Fernando 13 December 2013 (has links)
Este trabalho tem como objetivo compreender o comportamento térmico da excitatriz estática da Usina Hidrelétrica Derivação do Rio Jordão (UHEDRJ), empregando redes de Bragg em fibra ótica como sensor de temperatura. São apresentados os componentes da excitatriz estática, com foco na ponte retificadora trifásica controlada a tiristores. Com a calibração pôde-se conhecer os erros e incertezas dos sensores, tendo as maiores contribuições de incerteza devidas à dispersão das amostras e ajuste das curvas pelo método dos mínimos quadrados. A instrumentação da excitatriz estática permite que sejam realizados ensaios em diversas condições de operação da unidade geradora: partida da unidade, excitação a vazio, ou seja, com o gerador energizado, mas sem estar conectado ao sistema elétrico; excitada e sincronizada, ou seja, gerador energizado e sincronizado com o sistema elétrico; rampa de carga até a carga nominal e parada da unidade. Os ensaios realizados permitem estimar o comportamento térmico da ponte retificadora, variações de temperatura de cada tiristor no painel e como ocorrem as dissipações térmicas. / This work aims to study the static exciter thermal behavior of the hydroelectric power plant Rio Jordão (UHEDRJ) using fiber Bragg gratings as temperature sensor. The components of the static exciter are presented, with a focus on three-phase thyristor controlled bridge rectifier. The calibration allows knowing the errors and uncertainties of the sensors and the greatest uncertainty contributions due to dispersion of the samples and adjusting the curves by the method of minimun squares. The static exciter instrumentation allows performed the tests in various operating conditions of the generating unit: starting unit, excitation empty (with the generator energized but not connected to the grid); excited and synchronized (energized and synchronized with the power grid), ramp load to rated load and the unit stopped. The tests allow to estimate the thermal behavior of the bridge rectifier, temperature variations of each thyristor in the panel and how occur the thermal dissipation.
26

Análise comparativa de medidor de vazão em flare por tecnologia ótica e pitometria utilizando túnel de vento

Silva, Felipe Carvalho da 25 July 2012 (has links)
Made available in DSpace on 2016-12-23T14:08:09Z (GMT). No. of bitstreams: 1 Felipe Carvalho da Silva.pdf: 4181457 bytes, checksum: 8aef395272a667525a72d34c5ffb865f (MD5) Previous issue date: 2012-07-25 / With recent discoveries by the oil industry related to the reserves in Brazilian pre-salt, flow measurement technology is being re-evaluated in view of the large CO2 concentrations found in these reserves. A technology that has accuracy levels similar to those obtained with flow meters currently used and also measures independent characteristics to the composition and thermodynamic properties of gases is optical flow measurement velocimetry (OFM). The present work is related to experimental study, comparison of the speed readings from Pitot tube flow meters and optical velocimetry. This experimental study consists of qualifying and quantifying the velocity profiles among the possible configurations of flow in the wind tunnel, proposing methodology using flow conditioners and damping of the readings obtained with the Pitot tube, and analysis of readings taken with the optical sensor to evaluate the device installation effects in the results. The results indicate that transit-time optical flow meters for medium to high speed levels, could provide readcohesive flow even in a misalignment of up to ± 5 °, although it appears in the installation manual of the manufacturer guarantees of results meter when a misalignment of at most up to ±2º. Regarding the optical sensor intrusive effect in the readings simultaneous with the Pitot tube, it is perceived, in general, from approximately Re> 2,05x105, the intrusive effect of this influence is suppressed by other effects. Finally, for a proper flow study through Pitometry in order to make the comparison with the optical flow metering and achieve satisfactory results with the Pitot tube, the use of specific devices of flow conditioning and damping of the measured values had to be made / Com as recentes descobertas da indústria petrolífera brasileira, relacionadas às reservas no pré-sal, a tecnologia de medição de vazão está sendo reavaliada, tendo em vista as grandes concentrações de CO2 encontradas nessas reservas. A tecnologia de medição de vazão por velocimetria óptica (OFM) possui níveis de precisão semelhantes aos obtidos com os medidores de vazão utilizados atualmente. Essa tecnologia possui as características de independência com relação à composição química e às propriedades termodinâmicas dos gases. O presente trabalho se dedica ao estudo experimental de comparação das leituras de velocidade entre tubo de Pitot e medidor de vazão por velocimetria óptica. Para isso foi efetuada qualificação e quantificação dos perfis de velocidades em escoamento no túnel de vento, propondo metodologia de uso de retificadores de fluxo e amortecimento das leituras obtidas com o tubo de Pitot, e análises de leituras realizadas com o sensor óptico visando avaliar os efeitos de instalação do dispositivo nos resultados obtidos. Os resultados indicam que medidores de vazão ópticos por tempo de trânsito, para níveis médios e altos de velocidade, podem fornecer a leitura esperada da vazão mesmo estando num desalinhamento de ±5º, apesar de constar no manual de instalação do fabricante garantia destes resultados do medidor quando num desalinhamento de, no máximo, até ±2º. Com relação ao efeito intrusivo do sensor óptico nas leituras simultâneas com o tubo de Pitot, percebe-se, em geral, que a partir de aproximadamente Re> 2,05x105, o efeito intrusivo desta influência foi suprimido por outros efeitos. Por fim, para uma devida caracterização do escoamento por meio de pitometria, a fim de efetuar a comparação com a medição Laser, e alcançar satisfatórios resultados com o tubo de Pitot, foi necessário fazer uso de dispositivos específicos como retificadores de fluxo e de amortecimento (damping) dos valores medidos
27

Sensor óptico para monitoração de escoamento bifásico em golfadas

Daum, Hilson Henrique 04 October 2013 (has links)
LACIT / Escoamentos bifásicos gás-líquido estão presentes em inúmeras aplicações de engenharia, como por exemplo, na produção de petróleo, onde óleo e gás escoam nas linhas de produção. A monitoração online do escoamento bifásico é de grande importância para operação segura e eficiente dos processos de produção. Assim, nos últimos anos tem-se buscando o desenvolvimento de técnicas simples e de baixo custo para monitoração do escoamento da produção. Das diversas formas que um escoamento bifásico se apresenta, o padrão de escoamento em golfadas é o mais comum nas linhas de produção. Este trabalho apresenta um sistema óptico infravermelho que mede especificamente a velocidade das bolhas de gás em um escoamento em golfadas. Esse sistema emprega componentes optoeletrônicos operando a 950 nm juntamente com uma peça adutora utilizada para manter estáticos o emissor e receptor de luz. O circuito eletrônico responsável pelo funcionamento do sensor é composto por três canais de medição modulados em frequências diferentes. Dessa forma pelo tempo de trânsito que uma bolha leva no percurso entre os canais, pode-se calcular a velocidade da bolha. Essa técnica óptica traz a vantagem de ser um sistema de medição não invasivo e pode ser utilizado para outros fluidos, mas é necessário adaptar o comprimento de onda de trabalho de acordo com as características do fluido a ser detectado. O sistema desenvolvido foi testado em uma planta piloto sob diversas condições operacionais e comparado com sensores de referência (wire-mesh e câmera de alta velocidade). Resultados obtidos mostram o bom desempenho do sistema com relação aos sensores de referência. / Gas-liquid two-phase flows are present in many engineering applications such as in petroleum production, where oil and gas stream in the production lines. The online monitoring of two-phase flow is of great importance for safe and efficient operation of production processes. Thus, in recent years there has been an attempt to develop simple and low cost techniques for flow production monitoring. Among the various ways a two-phase flow may occur in a pipe, the flow pattern known as slug flow is the most common in production lines. This work presents an infrared optical system that specifically measures the translational speed of gas bubbles in slugs flow. This system employs optoelectronic components operating at 950 nm along with a mechanical assembly used to assure optical alignment of light emitters and receivers. The electronic circuitry responsible for operating the sensor consists of three measuring channels modulated at different frequencies, thus by measuring the time lag a gas bubble needs to travel from one channel to another, one can calculate speed of gas bubble. This optical technique has the advantage of being a noninvasive measurement system and can be used for other fluids, but it is necessary to adapt the working wavelength according to the characteristics of the fluid to be detected. The developed system was tested in a pilot plant under various operating conditions and compared with reference sensors (wire-mesh and high-speed camera). Results show the good performance of the system with respect to the reference sensors.
28

Detector de luminescência de descargas eletrocirúrgicas / Luminescence Detector of Electrosurgical Discharges

Góes, Sandro Waldir 04 October 2016 (has links)
A eletrocirurgia é um procedimento utilizado em cirurgias e basicamente promove o corte e a coagulação do tecido orgânico. Este procedimento usa a descarga elétrica que ocorre entre um eletrodo metálico e o tecido orgânico. As características deste tipo de descarga elétrica permanecem ainda pouco estudadas, mesmo um século após seu primeiro uso. Neste trabalho, o desenvolvimento de um dispositivo detector da luminescência da faísca eletrocirúrgica é relatado e os resultados de sua aplicação em laboratório analisados. O dispositivo é capaz de detectar flashes luminosos em centenas de kHz, possibilitando a visualização da luz emitida pelas descargas eletrocirúrgicas. Método: O dispositivo fotodetector é composto por um diodo PIN em um amplificador de transimpedância. Devido ao forte ruído eletromagnético da faiscância, o emprego de fibras ópticas para distanciamento entre o circuito e a fonte de ruído foi necessário e uma forte blindagem foi implementada. Resultados: O dispositivo detector de luminescência, juntamente com um gerador de saída eletrocirúrgica e equipamentos de medição, foi utilizado para captar e armazenar o sinal de luminescência em relação aos sinais de tensão e corrente geradores da faísca eletrocirúrgica. Foi possível, então, relacionar a luz emitida pelas faíscas com os sinais elétricos da descarga eletrocirúrgica, possibilitando um novo entendimento do funcionamento do espaço eletrocirúrgico, evidenciando a forte assimetria do processo, anteriormente já reportada na literatura através de outros métodos. Conclusão: O dispositivo desenvolvido provou ser efetivo para o estudo da luminescência emitida por descargas eletrocirúrgicas, possibilitando um novo canal de estudo das mesmas, principalmente a velocidade de resposta. / The electrosurgical procedure, used in large surgeries, promotes cut and/or coagulation of the organic tissue. This procedure is possible because the electrical discharge between a metal electrode and the organic tissue. Characteristics of the spark are still almost unknown. This work intends to collaborate to the electrosurgical sparks study, reporting the development of a photodetector device, capable to detect flashes of light in hundreds of kHz, and introducing the waveform of luminescence from the electrosurgical discharge. Methods: The photodetector deviceis composed mainly of a photodiode PIN and an transimpedance amplifier. Spacial care has taken to isolate the device from electromagnetic noise, employing a shield and an optical fiber cable. To obtain, analyze and store data, a specific hardware, software and techniques, have been used and described in detail. Results: From the luminescence signal detected by photodetector device and voltage and current shapes stored in an oscilloscope, it is possible to see the relation between sparks luminescence, voltage and current on positive and negative cycles of the electrical discharge. The luminescence collaborates to show the asymmetry on voltage signals already reported by other researchers. Conclusion: Effective for the study of luminescence emitted by electrosurgical discharges, enabling a new study of the same channel, particularly the speed of response.
29

Aplicação de sensores à fibra óptica no monitoramento térmico de painel fotovoltaico / Fiber optic sensor application in the monitoring of photovoltaic panel

Santolin, Edson Antonio 12 August 2016 (has links)
Neste trabalho foi estudada a aplicação das redes de Bragg em fibra óptica, como sensores no monitoramento e mapeamento térmico de um painel fotovoltaico instalado em ambiente aberto. Também foi analisada a capacidade desses sensores em detectar anomalias elétricas do painel, as quais são manifestadas pelas mudanças na temperatura. Devido ao fato de ser pioneiro no estudo da fibra óptica em painéis fotovoltaicos, o presente trabalho buscou comparar os resultados alcançados por esta tecnologia com os dados das demais técnicas de medição de temperatura, como por exemplo, o PT100 e câmera IR. Os ensaios foram realizados utilizando um painel fotovoltaico instalado em ambiente aberto, onde as suas variações de temperatura foram medidas por 27 sensores de fibra óptica instalados em sua superfície frontal. Durante todos os ensaios as condições ambientais de temperatura ambiente, nível de radiação solar e velocidade do vento foram monitorados. Os resultados demonstraram potencialidade de utilização das redes de Bragg em fibra óptica na detecção de variações térmicas ocasionadas por fatores ambientais ou aquecimento nas células. / This paper has been studying the applications of Bragg gratings in optical fibers, as sensors for thermal mapping and monitoring on photovoltaic panel surface which was installing in an open environment. We also analyzed the ability of optical fibers sensors to detect electrical anomalies in the panel, which are manifested by the changes in its temperature. Because it was pioneering in study of optical fiber application into photovoltaic panel, this paper's objective is compare the results between this technology and the other techniques for temperature measurements, for example when are used the PT100 sensors or infrared camera. Assays were performed using a photovoltaic panel that is installed in an open environment, its temperature changes were measured by a total of 27 optical fiber sensors installed on the front surface. During the tests, the environmental conditions of temperature, level of solar radiation and wind speed, were monitored. The results demonstrate the potential use of Bragg gratings in optical fiber for detecting thermal fluctuations caused by environmental factors or by heating the cells.
30

Monitoração de vibrações de estruturas com o emprego de sensores em fibra óptica

Silva, Jean Carlos Cardozo da January 2005 (has links)
Este trabalho tem por objetivo analisar as perspectivas do estudo de vibrações de estruturas, empregando sistemas sensores baseados em redes de Bragg em fibras óticas. O entendimento das vibrações nas estruturas possibilita o estudo de novos materiais e de novos sistemas construtivos que possam otimizar o dimensionamento e a segurança nos projetos de engenharia. Para as medidas de vibração é apresentado um sistema de leitura de redes de Bragg que tem como características o baixo custo e a facilidade de implementação, quando comparado a outros instrumentos. O aparelho pode ser acoplado a sistemas de aquisição comerciais, pois o sinal analógico de saída está condicionado entre 0 V e 5 V. Os resultados obtidos demonstram a capacidade do sistema em monitorar vibrações em diferentes tipos de materiais, tais como: madeira, aço, concreto e osso. Os resultados das medições feitas com modelos de laboratório mostram-se promissores na análise de vibrações em estruturas, quando comparados aos obtidos por sensores comerciais dos tipos, extensômetro elétrico de resistência e acelerômetro. Para além de estruturas civis, foram realizados estudos para o desenvolvimento de uma nova técnica de ensaio, in vitro, para caracterizar um novo conceito de implante dentário. Os resultados de ensaios de vibrações livres foram realizados com uma barra metálica, com vigas de madeira laminada colada, com vigas de concreto e implantes dentários onde as redes de Bragg foram empregadas. Esses resultados demonstram a capacidade do sensor em monitorar os efeitos de degradação das estruturas através de diferentes técnicas de análise modal. / This work deals with the analysis of perspectives of dynamic study in structures using a sensor system based on fibre optic Bragg gratings. The understanding of vibrations in structures enables the development of new materials, and of new design concepts that improves the sizing and security in engineering projects. The vibration measurements are carried out with a fibre optic Bragg grating demodulation system. The system has a low cost and easiness of implementation when compared to other available instruments. The output range signal of the instrument is between 0 V to 5 V, compatible to standard PC interfacing systems. The results show that the system is able to monitor vibrations in different types of materials, such as wood, steel, reinforced concrete and bone. The sensor is compared to commercial sensors (strain gauges and accelerometer). Beyond of civil structure, studies have been carried out to develop a technique, in vitro, to evaluate a new dental implant concept. The modal analysis techniques employed in the characterization of the different structures studied show the necessity of instrumentation able to measure low amplitude signals with high signal noise ratio. These characteristics are considered essential in material degradation studies by modal analysis technique.

Page generated in 0.0738 seconds