• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 2
  • Tagged with
  • 8
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Caractérisation du frisson chez l’humain et ses effets sur les comportements sensorimoteurs

Imbeault, Marie-Andrée January 2014 (has links)
La présente thèse de doctorat caractérise le frisson chez l’humain en plus d’évaluer les effets d’une exposition au froid et du frisson sur le contrôle sensorimoteur. Quatre études ont été complétées : la première a déterminé l’influence de la périphérie dans la modulation du frisson lors de changements rapides de la température environnementale, la deuxième a caractérisé le signal efférent du frisson en s’attardant à la cohérence bilatérale et entre les muscles du même côté du corps, la troisième a évalué l’effet d’une modalité d’entraînement sur le patron de frisson et la quatrième a déterminé l’effet d’une exposition locale au froid et l’effet du frisson sur la dextérité manuelle et la prise de précision (pouce-index). La première étude a déterminé que les thermorécepteurs cutanés jouent un rôle majeur dans la modulation du frisson chez l’humain puisqu’une inhibition systématique du frisson lors des périodes des expositions à 33 ºC a été observée et ce, malgré des températures de la peau bien en-dessous des températures observées en situation thermoneutres. Les résultats de la deuxième étude suggèrent que la voie réticulospinale est la voie efférente du frisson chez l’humain vue le parallèlle entre son anatomie et la coordination des signaux musculaires au niveau des deux composantes du frisson. La troisième étude suggère que la modalité d’entraînement, endurance et résistantce, n’affecte pas le patron de frisson et que l’origine de ce dernier semble inhérente au système neuromusculaire. La quatrième étude a observé que les effets néfastes du froid semblent être liés à la nature de la tâche. Somme toute, le frisson chez l’humain semble avoir un effet détériorant tant sur le contrôle sensorimoteur, dû aux tremblements, que sur le contrôle postural du tronc et des bras, dû à la généralisation des bouffées demandant une activation musculaire additionnelle.
2

Développement, validation clinique et valorisation d'une nouvelle technologie pour la rééducation de la dextérité manuelle / Development, clinical validation and evaluation of a new technological tool for the rehabilitation of manual dexterity

Térémetz, Maxime 27 September 2016 (has links)
La dextérité manuelle est au centre de notre interaction physique avec le monde. La sophistication des mouvements des doigts chez l’homme nécessite le contrôle de plusieurs composants clés comme la force, l’indépendance, le timing et le séquençage des mouvements des doigts. La dextérité est souvent affectée dans de nombreuses pathologies impactant l’indépendance et la vie quotidienne des patients. Le but global de cette thèse est d’améliorer la rééducation de la dextérité chez ces patients par une meilleure mesure et compréhension de la dextérité et de ses composants. Nous avons développé le Finger Force Manipulandum (FFM), un outil permettant de quantifier les principaux composants de la dextérité chez des sujets sains et des patients. Afin de valider cet appareil, nous avons testé la faisabilité de son utilisation chez des patients souffrant d’un important déficit de dextérité après un accident vasculaire cérébral. Le FFM permet, chez ces patients (N= 10 vs N= 10 sujets sains), de quantifier les différents composants de la dextérité et d’identifier des déficits dans chacun d’entre eux (exemple : les patients font trois fois plus d’erreur que les témoins pour le contrôle de force ; P=0,0002). Les mesures sont plus sensibles que certains tests cliniques comme l’ARAT : elles permettent de détecter des déficits de la dextérité même chez des patients atteignant le score maximum de l’ARAT. Le FFM permet également de créer un profil de dextérité affectée chez chaque patient permettant ainsi de détecter quel composant est significativement affecté et permet aussi de suivre la récupération. Dans une maladie affectant légèrement la dextérité, comme la schizophrénie, lorsque l’on compare les scores FFM des patients stabilisés (N= 35) avec ceux des témoins (N= 20) on constate que les patients ont une performance diminuée de façon significative dans chacun des quatre composants de la dextérité. Certaines des mesures du FFM corrèlent avec des échelles cliniques comme la PANSS (R=0,53, P=0,0019) mais aussi avec des échelles neuropsychologiques. Ces mesures FFM sont également assez sensibles pour détecter une évolution au cours du temps : certains composants restent stables après une remédiation cognitive alors que d’autres s’améliorent. En conclusion, le FFM est un nouvel outil qui permet de quantifier les différents composants de la dextérité. Il est utilisable même chez des patients avec un important déficit manuel et permet d’identifier des profils individuels de dextérité affectée. Il est également assez sensible pour détecter de faibles diminutions de performances motrices comme celles retrouvées chez des patients schizophrènes et pourrait permettre d’identifier certains marqueurs moteurs ayant trait au background neuro-développemental des patients schizophrènes (détection précoce) et à l’évolution de la maladie. / Manual dexterity is essential for our physical interaction with the world. The high degree of dexterity in humans requires sophisticated control of several key components such as the control of force, of independence, timing and sequencing of finger movements. Manual dexterity is affected in various pathologies, impacting activities of daily living and leading to loss of independence. The main purpose of this thesis is to improve rehabilitation of dexterity in these patients by a better behavioral quantification and a clearer understanding of manual dexterity and its components of control. We developed the Finger Force Manipulandum (FFM), a new tool allowing for the quantification of the main components of the dexterity in healthy subjects and in patients. To validate this device, we tested the feasibility of its use with stroke patients suffering from moderate-to-severe deficits of dexterity. In these patients, the FFM allowed for quantification of four components of dexterity and for identification of deficits in each of them (example: patients (N=10) made three times more error than controls (N=10) in force control; P=0.0002). These measures (components) are more sensitive than clinical tests, such as the ARAT: patients reaching the maximum ARAT score still showed deficits of dexterity with the FFM. Based on the four FFM scores, individual profiles of affected dexterity were calculated, highlighting the individual deficit of each patient. This allowed for quantitative longitudinal follow up during recovery. In a disease affecting dexterity mildly, such as schizophrenia, the FFM scores of stabilized patients (N = 35) indicated a significantly lower performance compared to control subjects (N = 20) in each of the four dexterity components. Some of the FFM measures correlated with clinical scales, such as the PANSS (R=0.53, P=0.0019), and also with some neuropsychological scales. These FFM measures also provide indicators for the evolution of dexterity over time: certain components remained stable after cognitive remediation, while others improved. In conclusion, the FFM is a new tool, which allows for quantification of manual dexterity (by measuring various underlying components). It is suitable for patients with moderate-to-sever manual deficits and allows for identification of individual profiles of affected dexterity. It also detects minor manual deficits in schizophrenic patients, and may allow for identification of potential behavioral markers related to the neurodevelopmental background of schizophrenic patients (early detection) and to the evolution of the disease.
3

Conception Robuste de Mécanismes

Caro, Stéphane 17 December 2004 (has links) (PDF)
Les travaux présentés dans cette thèse portent sur l'étude de la robustesse de la conception de mécanismes. Ses principales contributions résident dans la détermination d'un indice de robustesse, le développement de deux méthodes d'analyse de sensibilité pour les manipulateurs d'architecture parallèle de type Delta-Linéaire, la formulation d'une procédure de synthèse de tolérances et l'étude de la robustesse d'une famille de manipulateurs d'architecture sérielle génériques et non-génériques<br />à trois degrés de liberté. Le mémoire est ainsi divisé en quatre chapitres. Le premier chapitre est consacré à une énumération des propriétés générales des mécanismes étudiés, à une étude bibliographique de la conception robuste et à la formulation d'un problème de conception robuste. Le deuxième chapitre traite de l'analyse de sensibilité de l'Orthoglide, manipulateur d'architecture parallèle de type Delta-Linéaire à trois degrés de liberté de translation. L'étude permet de connaître la sensibilité<br />de la situation de l'effecteur du manipulateur aux variations de ses paramètres géométriques et de repérer les configurations pour lesquelles cette sensibilité est minimale et maximale. Le troisième chapitre présente un indice de robustesse optimal pour<br />les mécanismes étudiés et une procédure de synthèse de tolérances dimensionnelles décomposée en deux étapes séquentielles. Par ailleurs, ils sont illustrés par plusieurs études de cas, notamment un amortisseur et un manipulateur d'architecture parallèle. Finalement, le quatrième chapitre décrit une étude de la robustesse d'une famille de manipulateurs d'architecture sérielle à trois degrés de liberté. Cette étude vise à identifier les corrélations entre les notions de robustesse et de généricité.<br />A cet effet, différentes notions de la robotique sont exploitées, telles que la parcourabilité, la précision et la dextérité d'un manipulateur. Il s'avère que la généricité d'un manipulateur n'a pas d'influence sur ses performances cinématiques, ni sur la sensibilité de la position de son effecteur aux variations de ses paramètres géométriques.
4

Effets de la vibration des muscles sur les mécanismes neuronaux et la fonction du membre supérieur et inférieur des personnes ayant une hémiparésie chronique

de Andrade Melo, Sibele 08 1900 (has links)
Cette thèse vise à répondre à trois questions fondamentales: 1) La diminution de l’excitabilité corticospinale et le manque d’inhibition intracorticale observés suite à la stimulation magnétique transcrânienne (SMT) du cortex moteur de la main atteinte de sujets hémiparétiques sont-ils aussi présents suite à la SMT du cortex moteur de la jambe atteinte? 2) Est-ce que les altérations dans l’excitabilité corticomotrice sont corrélées aux déficits et incapacités motrices des personnes ayant subi un accident vasculaire cérébral depuis plus de 6 mois? 3) La vibration musculaire, étant la source d’une forte afférence sensorielle, peut-elle moduler l’excitabilité corticomotrice et améliorer la performance motrice de ces personnes? Premièrement, afin d’appuyer notre choix d’intervention et d’évaluer le potentiel de la vibration mécanique locale pour favoriser la réadaptation des personnes ayant une atteinte neurologique, nous avons réalisé une révision en profondeur de ses applications et intérêts cliniques à partir d’informations trouvées dans la littérature scientifique (article 1). La quantité importante d’information sur les effets physiologiques de la vibration contraste avec la pauvreté des études qui ont évalué son effet thérapeutique. Nous avons trouvé que, malgré le manque d’études, les résultats sur son utilisation sont encourageants et positifs et aucun effet adverse n’a été rapporté. Dans les trois autres articles qui composent cette thèse, l’excitabilité des circuits corticospinaux et intracorticaux a été étudiée chez 27 sujets hémiparétiques et 20 sujets sains sans atteintes neurologiques. Les fonctions sensorimotrices ont aussi été évaluées par des tests cliniques valides et fidèles. Tel qu’observé à la main chez les sujets hémiparétiques, nous avons trouvé, par rapport aux sujets sains, une diminution de l’excitabilité corticospinale ainsi qu’un manque d’inhibition intracorticale suite à la SMT du cortex moteur de la jambe atteinte (article 2). Les sujets hémiparétiques ont également montré un manque de focus de la commande motrice lors de l’activation volontaire des fléchisseurs plantaires. Ceci était caractérisé par une augmentation de l’excitabilité nerveuse des muscles agonistes, mais aussi généralisée aux synergistes et même aux antagonistes. De plus, ces altérations ont été corrélées aux déficits moteurs au membre parétique. Le but principal de cette thèse était de tester les effets potentiels de la vibration des muscles de la main (article 3) et de la cuisse (article 4) sur les mécanismes neuronaux qui contrôlent ces muscles. Nous avons trouvé que la vibration augmente l’amplitude de la réponse motrice des muscles vibrés, même chez des personnes n’ayant pas de réponse motrice au repos ou lors d’une contraction volontaire. La vibration a également diminué l’inhibition intracorticale enregistrée au quadriceps parétique (muscle vibré). La diminution n’a cependant pas été significative au niveau de la main. Finalement, lors d’un devis d’investigation croisé, la vibration de la main ou de la jambe parétique a résulté en une amélioration spécifique de la dextérité manuelle ou de la coordination de la jambe, respectivement. Au membre inférieur, la vibration du quadriceps a également diminuée la spasticité des patients. Les résultats obtenus dans cette thèse sont très prometteurs pour la rééducation de la personne hémiparétique car avec une seule séance de vibration, nous avons obtenu des améliorations neurophysiologiques et cliniques. / This thesis aims to answer three basic questions: 1) Are the decrease in corticospinal excitability and the lack of intracortical inhibition observed following transcranial magnetic stimulation (TMS) of the affected hand motor cortex of stroke patients present after TMS of the affected leg motor cortex? 2) Are the alterations in corticomotor excitability correlated with motor impairments and disabilities of subjects who have suffered a stroke for over six months? 3) Can muscle vibration, as a source of strong sensory afference modulate corticomotor excitability and improve motor performance of these subjects? First of all, to support our choice of intervention and to assess the potential of local mechanical vibration to promote the recovery of persons with neurological impairment, we conducted a thorough review of its physiological effects and clinical applications in the scientific literature (article 1). The wealth of information on the physiological effects of vibration contrasts with the lack of studies that have evaluated its therapeutic effects. Nevertheless, we found that, despite the paucity of studies, the results on its clinical use are encouraging and positive and no adverse effects were reported. In the other three articles included in this thesis, the excitability of corticospinal and intracortical circuits has been studied in 27 hemiparetic patients and in 20 healthy subjects without neurological disease or injury. Sensorimotor functions were also evaluated with valid and reliable clinical tests. Similar to that observed in the hand of hemiparetic patients, we found, compared to the healthy subjects, a decrease of corticospinal excitability and a lack of intracortical inhibition following TMS of the affected leg motor cortex (Article 2). The hemiparetic patients also showed a lack of focus of the motor output during voluntary activation of plantar flexors. This was characterized by an increase in the neural excitability not only of the agonist muscles, but also of the synergists and even the antagonist muscles. The main goal of this thesis was to test the potential effects of vibrating hand (Article 3) and thigh (Article 4) muscles on the neural mechanisms that control these muscles. We found that vibration increases the amplitude of motor responses in the vibrated muscles and even produces a response in subjects with no motor response at rest or during a voluntary contraction. The vibration also decreased the intracortical inhibition recorded in the paretic quadriceps muscle (vibrated muscle). The decrease was however not significant at the hand. Finally, using a cross-over design study, the vibration of the paretic hand or leg resulted in specific improvements in hand dexterity or leg coordination, respectively. In the lower limb, quadriceps vibration also reduced the spasticity in patients. The results obtained in this thesis are very promising for stroke rehabilitation because with a single session of vibration, we obtained neurophysiological and clinical improvements.
5

Contribution à la conception d'un système robotisé pour la télé-échographie

Essomba, Terence 17 December 2012 (has links) (PDF)
L'apparition de la télé-échographie à la fin des années 1990 a largement contribué à l'améliorationdes capacités de prise en charge des patients. Aujourd'hui, le laboratoire PRISME bénéficie d'unsavoir faire reconnu dans la conception de systèmes de télé-échographie robotisée. L'objectif deces travaux de thèse est d'apporter une contribution scientifique et technique au projet ANR-PROSIT,qui vise à la mise en oeuvre d'un robot de télé-échographie innovant. Une étude du geste du praticienen milieu clinique a été menée afin d'en déterminer les caractéristiques cinématiques. Réalisée àl'aide du système de capture de mouvement Vicon Nexus, cette analyse a contribué à l'établissementdes spécifications du futur robot. Sa structure mécanique a fait l'objet d'une attention particulière. Unearchitecture parallèle sphérique a été sélectionnée, étudiée puis optimisée via un algorithmegénétique en fonction des critères d'espace de travail, de dextérité et de compacité. L'architectureainsi obtenue est ensuite analysée sur des aspects de collisions et d'inaccessibilité. Pour le contrôlede ce robot, l'utilisation d'une interface haptique à l'aspect proche d'une sonde d'échographie estproposée. Dotée d'un système de retour d'effort et d'une centrale inertielle fiabilisée par un filtre deKalman adaptatif, cette nouvelle interface a été testée et validée par le système Vicon Nexus.
6

Contribution à la conception et l'optimisation des systèmes haptiques / Contribution to the design and optimization of haptic systems

Chaker, Abdelbadia 26 November 2012 (has links)
L'objectif de ce travail est de concevoir une nouvelle interface haptique en vue de son exploitation pour la chirurgie mini-invasive. La technique d'anastomose ciblée consiste à réunir deux parties désolidarisées d'une artère par des sutures et des nœuds. Ceci est effectué par des outils chirurgicaux introduits à travers de petites incisions. Une étude expérimentale de cette tâche a été effectuée en collaboration avec des chirurgiens afin de caractériser leurs gestes. L'enregistrement de l'opération par un système de capture de mouvement a permis d'identifier la nature et les gestes canoniques de cette technique. Une structure parallèle sphérique a été ensuite adoptée comme base de l'interface haptique. Cette architecture présente un centre fixe de rotation semblable au point d'incision réel et offre les trois degrés de liberté de rotation nécessaires autours de ce point. Une étude détaillée de cette architecture suivie d'une phase d'optimisation, a permis d'adapter la structure à l'application chirurgicale. L'optimisation, basée sur un algorithme générique, a porté dans un premier lieu sur l'espace de travail de la tâche. La dextérité de la structure a été ensuite prise en compte. Une phase de conception basée sur les paramètres résultants de cette optimisation a aboutie à la réalisation d'un premier prototype. L'influence des erreurs de fabrication sur l'orientation de la plateforme a été aussi traitée dans ce travail afin de déterminer les plages des défauts admissibles. Une modélisation, utilisant les torseurs de petits déplacements, a été élaborée.La dernière partie de ce travail porte sur la commande a retour d'effort de l'interface. Un banc d'essais à 1 degré de liberté a été réalisé afin de tester les différents schémas de contrôle pour la téléopération. Les essais en simulation on permit de dresser une vue comparative de ces schémas. / The aim of this work is to develop a new haptic interface to perform a minimally invasive surgery. The targeted anastomosis technique consists of the surgical binding of a ruptured blood vessel, using sutures and knots. This task is performed by surgical tools inserted through small incisions. An experimental study of this task was conducted in collaboration with surgeons in order to characterize their gesture. The recording of the operation by a motion capture system helped identifying the nature and the canonical actions of this technique. A spherical parallel mechanism (SPM) was then adopted as a basis for the haptic interface. This architecture has a fixed center of rotation similar to the real incision point and offers the three required degrees of freedom of rotation around that point. A detailed study of the architecture followed by an optimization procedure led to a suitable mechanism for the surgical application. The optimization, which is based on a generic algorithm, used the workspace of the task as a criterion. Then the dexterity of the structure was taken into account. A design phase based on the parameters resulting from this optimization led to building the first prototype.The influence of manufacturing errors on the orientation of the platform was also addressed in this work to determine the ranges of allowable defects. The manufacturing errors are modeled by screws of small displacement in order to determine their effect on the orientation error of the end effector. The last part of this work focuses on the command of the force feedback interface. An experimental setup made out of a one degree of freedom system, was built to test different control schemes for teleoperation. Simulation trials allowed developing a comparative view of these schemes.
7

Effets de la vibration des muscles sur les mécanismes neuronaux et la fonction du membre supérieur et inférieur des personnes ayant une hémiparésie chronique

De Andrade Melo, Sibele 08 1900 (has links)
Cette thèse vise à répondre à trois questions fondamentales: 1) La diminution de l’excitabilité corticospinale et le manque d’inhibition intracorticale observés suite à la stimulation magnétique transcrânienne (SMT) du cortex moteur de la main atteinte de sujets hémiparétiques sont-ils aussi présents suite à la SMT du cortex moteur de la jambe atteinte? 2) Est-ce que les altérations dans l’excitabilité corticomotrice sont corrélées aux déficits et incapacités motrices des personnes ayant subi un accident vasculaire cérébral depuis plus de 6 mois? 3) La vibration musculaire, étant la source d’une forte afférence sensorielle, peut-elle moduler l’excitabilité corticomotrice et améliorer la performance motrice de ces personnes? Premièrement, afin d’appuyer notre choix d’intervention et d’évaluer le potentiel de la vibration mécanique locale pour favoriser la réadaptation des personnes ayant une atteinte neurologique, nous avons réalisé une révision en profondeur de ses applications et intérêts cliniques à partir d’informations trouvées dans la littérature scientifique (article 1). La quantité importante d’information sur les effets physiologiques de la vibration contraste avec la pauvreté des études qui ont évalué son effet thérapeutique. Nous avons trouvé que, malgré le manque d’études, les résultats sur son utilisation sont encourageants et positifs et aucun effet adverse n’a été rapporté. Dans les trois autres articles qui composent cette thèse, l’excitabilité des circuits corticospinaux et intracorticaux a été étudiée chez 27 sujets hémiparétiques et 20 sujets sains sans atteintes neurologiques. Les fonctions sensorimotrices ont aussi été évaluées par des tests cliniques valides et fidèles. Tel qu’observé à la main chez les sujets hémiparétiques, nous avons trouvé, par rapport aux sujets sains, une diminution de l’excitabilité corticospinale ainsi qu’un manque d’inhibition intracorticale suite à la SMT du cortex moteur de la jambe atteinte (article 2). Les sujets hémiparétiques ont également montré un manque de focus de la commande motrice lors de l’activation volontaire des fléchisseurs plantaires. Ceci était caractérisé par une augmentation de l’excitabilité nerveuse des muscles agonistes, mais aussi généralisée aux synergistes et même aux antagonistes. De plus, ces altérations ont été corrélées aux déficits moteurs au membre parétique. Le but principal de cette thèse était de tester les effets potentiels de la vibration des muscles de la main (article 3) et de la cuisse (article 4) sur les mécanismes neuronaux qui contrôlent ces muscles. Nous avons trouvé que la vibration augmente l’amplitude de la réponse motrice des muscles vibrés, même chez des personnes n’ayant pas de réponse motrice au repos ou lors d’une contraction volontaire. La vibration a également diminué l’inhibition intracorticale enregistrée au quadriceps parétique (muscle vibré). La diminution n’a cependant pas été significative au niveau de la main. Finalement, lors d’un devis d’investigation croisé, la vibration de la main ou de la jambe parétique a résulté en une amélioration spécifique de la dextérité manuelle ou de la coordination de la jambe, respectivement. Au membre inférieur, la vibration du quadriceps a également diminuée la spasticité des patients. Les résultats obtenus dans cette thèse sont très prometteurs pour la rééducation de la personne hémiparétique car avec une seule séance de vibration, nous avons obtenu des améliorations neurophysiologiques et cliniques. / This thesis aims to answer three basic questions: 1) Are the decrease in corticospinal excitability and the lack of intracortical inhibition observed following transcranial magnetic stimulation (TMS) of the affected hand motor cortex of stroke patients present after TMS of the affected leg motor cortex? 2) Are the alterations in corticomotor excitability correlated with motor impairments and disabilities of subjects who have suffered a stroke for over six months? 3) Can muscle vibration, as a source of strong sensory afference modulate corticomotor excitability and improve motor performance of these subjects? First of all, to support our choice of intervention and to assess the potential of local mechanical vibration to promote the recovery of persons with neurological impairment, we conducted a thorough review of its physiological effects and clinical applications in the scientific literature (article 1). The wealth of information on the physiological effects of vibration contrasts with the lack of studies that have evaluated its therapeutic effects. Nevertheless, we found that, despite the paucity of studies, the results on its clinical use are encouraging and positive and no adverse effects were reported. In the other three articles included in this thesis, the excitability of corticospinal and intracortical circuits has been studied in 27 hemiparetic patients and in 20 healthy subjects without neurological disease or injury. Sensorimotor functions were also evaluated with valid and reliable clinical tests. Similar to that observed in the hand of hemiparetic patients, we found, compared to the healthy subjects, a decrease of corticospinal excitability and a lack of intracortical inhibition following TMS of the affected leg motor cortex (Article 2). The hemiparetic patients also showed a lack of focus of the motor output during voluntary activation of plantar flexors. This was characterized by an increase in the neural excitability not only of the agonist muscles, but also of the synergists and even the antagonist muscles. The main goal of this thesis was to test the potential effects of vibrating hand (Article 3) and thigh (Article 4) muscles on the neural mechanisms that control these muscles. We found that vibration increases the amplitude of motor responses in the vibrated muscles and even produces a response in subjects with no motor response at rest or during a voluntary contraction. The vibration also decreased the intracortical inhibition recorded in the paretic quadriceps muscle (vibrated muscle). The decrease was however not significant at the hand. Finally, using a cross-over design study, the vibration of the paretic hand or leg resulted in specific improvements in hand dexterity or leg coordination, respectively. In the lower limb, quadriceps vibration also reduced the spasticity in patients. The results obtained in this thesis are very promising for stroke rehabilitation because with a single session of vibration, we obtained neurophysiological and clinical improvements.
8

Contribution à la conception d'un système robotisé pour la télé-échographie / Contribution to the design of a robotized tele-echography system

Essomba, Terence 17 December 2012 (has links)
L’apparition de la télé-échographie à la fin des années 1990 a largement contribué à l’améliorationdes capacités de prise en charge des patients. Aujourd’hui, le laboratoire PRISME bénéficie d’unsavoir faire reconnu dans la conception de systèmes de télé-échographie robotisée. L’objectif deces travaux de thèse est d’apporter une contribution scientifique et technique au projet ANR-PROSIT,qui vise à la mise en oeuvre d’un robot de télé-échographie innovant. Une étude du geste du praticienen milieu clinique a été menée afin d’en déterminer les caractéristiques cinématiques. Réalisée àl’aide du système de capture de mouvement Vicon Nexus, cette analyse a contribué à l’établissementdes spécifications du futur robot. Sa structure mécanique a fait l’objet d’une attention particulière. Unearchitecture parallèle sphérique a été sélectionnée, étudiée puis optimisée via un algorithmegénétique en fonction des critères d’espace de travail, de dextérité et de compacité. L’architectureainsi obtenue est ensuite analysée sur des aspects de collisions et d’inaccessibilité. Pour le contrôlede ce robot, l’utilisation d’une interface haptique à l’aspect proche d’une sonde d’échographie estproposée. Dotée d’un système de retour d’effort et d’une centrale inertielle fiabilisée par un filtre deKalman adaptatif, cette nouvelle interface a été testée et validée par le système Vicon Nexus. / Since the end of the nineties, the tele-echography has been contributing to improve the taking carecapacities of patients. Today, the PRISME laboratory has a recognized expertise in the design ofrobotic tele-echography systems. The objective of this thesis is to provide scientific and technicalsupport to the ANR-PROSIT project. It aims to design of an innovative tele-echography robot. Anexpert gesture study has been carried out in clinical environment to determine its kinematiccharacteristics. It has been performed using the motion capture system Vicon Nexus and itcontributed to establish the specifications of the future robot. The mechanic structure of this robot hasbeen minutely taken in consideration. The spherical parallel mechanism has been selected, studiedand optimized using a genetic algorithm with respect of criterion such as workspace, dexterity andcompacity. The resulted architecture is then analyzed regarding collisions and inaccessibilityaspects. To control this robot, the use of a haptic device with the same shape of an ultrasound probeis proposed. It provides force feedback and it is instrumented with an inertial measurement unit,processed by an adaptative Kalman filter. This new interface has been tested and validated by ViconNexus system.

Page generated in 0.0422 seconds