• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Elimination des acides humiques presents dans les eaux par adsorption et/ou photocatalyse / Removal of humic acids from water by adsorption and/or photocatalysis

Gueu, Soumahoro 26 April 2019 (has links)
Les ressources en eau sont menacées par diverses formes de pollution et les procédés de traitement proposés sont souvent complexes avec des résultats qui ne sont pas toujours satisfaisants. Cette étude vise à développer un traitement, simple et peu coûteux pour réduire au maximum la présence dans l’eau des acides humiques (AH), un polluant organique. L’approche adoptée est la mise en place d’un procédé hybride combinant l’adsorption et la photocatalyse hétérogène réalisée avec le dioxyde de titane. La méthode d’adsorption a été réalisée d’une part avec du charbon actif et d’autre part avec trois argiles provenant de la Côte d’Ivoire. Le charbon actif a été préparé à partir des coques de coco selon une procédure assez simplifiée, sans additifs chimiques, dans le souci d’obtenir un adsorbant économique et écologique. Les trois argiles brutes (Dabou, Yamoussoukro et Katiola) ont chacune subi des opérations de purification pour obtenir des fractions pures. Des tests de caractérisation réalisés par diverses techniques (analyse élémentaire, DRX, adsorption d’azote, IR, etc.) ont été effectués sur les adsorbants obtenus. Les essais d’adsorption réalisés avec le charbon ont montré qu’aucune élimination des AH n’a été observé. La raison principale serait le manque de groupements fonctionnels sur la surface du charbon préparé. Les tests d’adsorption conduit avec les argiles ont montré que ces matériaux sont capables d’éliminer les AH. Les résultats ont révélé que l’argile la plus riche en kaolinite (celle de Yamoussoukro) a une capacité d’adsorption maximale largement supérieure (115 mg/g) par rapport aux autres (20 et 15 mg/g pour Dabou et Katiola respectivement). Cette différence trouve son explication dans la composition minéralogique et structurale de chacune des argiles. Les tests de photocatalyse menés ont montré une dégradation des macromolécules d’AH en des composés de plus petites tailles. La minéralisation de la matière organique a été observée avec une réduction du carbone organique total de l’ordre de 72 et 82 % respectivement aux pH 7 et 3. En mettant en série à pH 3, les deux procédés à savoir l’adsorption suivie de la photocatalyse, une réduction de 95% du carbone organique total des AH est obtenue. Le procédé hybride ainsi réalisé montre un avantage certain car il permet d’éliminer la quasi-totalité de la pollution organique initiale. / Water resources are threatened by various forms of pollution and the proposed treatment processes are often complex with results that are not always satisfactory. This study aims to develop a simple and inexpensive treatment to minimize the presence of humic acids (HA), an organic pollutant, in water. The approach adopted is the establishment of a hybrid process combining adsorption and heterogeneous photocatalysis performed with titanium dioxide. The adsorption method was carried out primary with activated carbon and secondary with three clays from Ivory Coast. Activated carbon was prepared from coconut shell by a simplified procedure, without chemical additives, in order to obtain an economic and ecological adsorbent. The three raw clays (Dabou, Yamoussoukro and Katiola) each underwent purification operations to obtain pure fractions. Characterization tests including various techniques (elemental analysis, XRD, nitrogen adsorption, IR, etc.) were carried out on the adsorbents obtained. Adsorption tests carried out with the coal showed that no elimination of HA was observed. The main reason is the lack of functional groups on the surface of the prepared coal. The adsorption tests conducted with the clays have shown that these materials are capable of removing HA. The results revealed that the clay richest in kaolinite (Yamoussoukro) has a much higher maximum adsorption capacity (115 mg/g) compared to the others (20 and 15 mg/g for Dabou and Katiola respectively). This difference found its explanation in the mineralogical and structural composition of each of the clays. Photocatalysis tests showed a degradation of the macromolecules of HA into smaller sizes compounds. The mineralization of the organic matter was observed with total organic carbon reduction rate equal to 72 and 82% at pH 7 and 3 respectively. By placing in series the two processes namely adsorption followed by photocatalysis, the removal percentage of HA obtained at pH 3, is about 95%. This hybrid process shows an advantage since it makes it possible to eliminate almost all of the initial organic pollution.
2

Influence de la taille de départ, de l’état d’agglomération et de la dose de nanoparticules de dioxyde de titane (TiO2) inhalées sur la réponse pulmonaire chez le rat

Noël, Alexandra 02 1900 (has links)
En raison de leur petite taille, les nanoparticules (NP) (< 100 nm) peuvent coaguler très rapidement ce qui favorise leur pénétration dans l’organisme sous forme d’agglomérats. L’objectif de cette recherche est d’étudier l’influence de l’état d’agglomération de NP de dioxyde de titane (TiO2) de trois tailles de départ différentes, 5, 10-30 ou 50 nm sur la toxicité pulmonaire chez le rat mâle (F344) exposé à des aérosols de 2, 7 ou 20 mg/m3 pendant 6 heures. Dans une chambre d’inhalation, six groupes de rats (n = 6 par groupe) ont été exposés par inhalation aiguë nez-seulement à des aérosols ayant une taille primaire de 5 nm, mais produits sous forme faiblement (< 100 nm) ou fortement (> 100 nm) agglomérée à 2, 7 et 20 mg/m3. De façon similaire, quatre autres groupes de rats ont été exposés à 20 mg/m3 à des aérosols ayant une taille primaire de 10-30 et 50 nm. Les différents aérosols ont été générés par nébulisation à partir de suspensions ou par dispersion à sec. Pour chaque concentration massique, un groupe de rats témoins (n = 6 par groupe) a été exposé à de l’air comprimé dans les mêmes conditions. Les animaux ont été sacrifiés 16 heures après la fin de l’exposition et les lavages broncho-alvéolaires ont permis de doser des marqueurs d’effets inflammatoires, cytotoxiques et de stress oxydant. Des coupes histologiques de poumons ont également été analysées. L’influence de l’état d’agglomération des NP de TiO2 n’a pu être discriminée à 2 mg/m3. Aux concentrations massiques de 7 et 20 mg/m3, nos résultats montrent qu’une réponse inflammatoire aiguë est induite suite à l'exposition aux aérosols fortement agglomérés. En plus de cette réponse, l’exposition aux aérosols faiblement agglomérés à 20 mg/m3 s’est traduite par une augmentation significative de la 8-isoprostane et de la lactate déshydrogénase. À 20 mg/m3, les effets cytotoxiques étaient plus importants suite à l’exposition aux NP de 5 nm faiblement agglomérées. Ces travaux ont montré dans l'ensemble que différents mécanismes de toxicité pulmonaire peuvent être empruntés par les NP de TiO2 en fonction de la taille de départ et de l’état d’agglomération. / Given their small size, nanoparticles (NP) (< 100 nm) can coagulate quickly, which promotes their entry into the body in the form of agglomerates. The objective of this study is to evaluate the influence of the agglomeration state of three different primary particle sizes (5, 10-30 and 50 nm) of titanium dioxide (TiO2) NP on the pulmonary toxicity of male rats (F344) exposed to aerosols at 2, 7 or 20 mg/m3 for 6 hours. In an inhalation chamber, six groups of rats (n = 6 per group) were acutely exposed by nose-only inhalation to aerosols with a 5-nm primary particle size, produced in the form of small agglomerates (< 100 nm) (SA) or large agglomerates (> 100 nm) (LA) at 2, 7 and 20 mg/m3. Similarly, four other groups of rats were exposed to aerosols at 20 mg/m3 with a primary particle size of 10-30 and 50 nm. The different aerosols were generated by nebulization of suspensions or by dry dispersion. For each mass concentration, one group of control rats (n = 6 per group) was exposed to compressed air under the same conditions. The animals were sacrificed 16 hours after the end of exposure, and analysis of the bronchoalveolar lavage fluids was used to measure markers of inflammatory, cytotoxicity and oxidative stress effects. Lung sections were also analyzed for histopathology. The influence of the agglomeration state of TiO2 NP (5 nm) could not be determined at 2 mg/m3. For mass concentrations of 7 and 20 mg/m3, our results showed that an acute inflammatory response was induced following exposure to LA aerosols. In addition to this response, exposure to SA aerosols resulted in a significant increase in 8-isoprostane and lactate dehydrogenase. At 20 mg/m3, the cytotoxic effects were greater after exposure to the 5-nm NP in the SA aerosol. This study showed that TiO2 NP use different mechanisms to induce their pulmonary toxicity as a function of their primary particle size and their agglomeration state.
3

Influence de la taille de départ, de l’état d’agglomération et de la dose de nanoparticules de dioxyde de titane (TiO2) inhalées sur la réponse pulmonaire chez le rat

Noël, Alexandra 02 1900 (has links)
En raison de leur petite taille, les nanoparticules (NP) (< 100 nm) peuvent coaguler très rapidement ce qui favorise leur pénétration dans l’organisme sous forme d’agglomérats. L’objectif de cette recherche est d’étudier l’influence de l’état d’agglomération de NP de dioxyde de titane (TiO2) de trois tailles de départ différentes, 5, 10-30 ou 50 nm sur la toxicité pulmonaire chez le rat mâle (F344) exposé à des aérosols de 2, 7 ou 20 mg/m3 pendant 6 heures. Dans une chambre d’inhalation, six groupes de rats (n = 6 par groupe) ont été exposés par inhalation aiguë nez-seulement à des aérosols ayant une taille primaire de 5 nm, mais produits sous forme faiblement (< 100 nm) ou fortement (> 100 nm) agglomérée à 2, 7 et 20 mg/m3. De façon similaire, quatre autres groupes de rats ont été exposés à 20 mg/m3 à des aérosols ayant une taille primaire de 10-30 et 50 nm. Les différents aérosols ont été générés par nébulisation à partir de suspensions ou par dispersion à sec. Pour chaque concentration massique, un groupe de rats témoins (n = 6 par groupe) a été exposé à de l’air comprimé dans les mêmes conditions. Les animaux ont été sacrifiés 16 heures après la fin de l’exposition et les lavages broncho-alvéolaires ont permis de doser des marqueurs d’effets inflammatoires, cytotoxiques et de stress oxydant. Des coupes histologiques de poumons ont également été analysées. L’influence de l’état d’agglomération des NP de TiO2 n’a pu être discriminée à 2 mg/m3. Aux concentrations massiques de 7 et 20 mg/m3, nos résultats montrent qu’une réponse inflammatoire aiguë est induite suite à l'exposition aux aérosols fortement agglomérés. En plus de cette réponse, l’exposition aux aérosols faiblement agglomérés à 20 mg/m3 s’est traduite par une augmentation significative de la 8-isoprostane et de la lactate déshydrogénase. À 20 mg/m3, les effets cytotoxiques étaient plus importants suite à l’exposition aux NP de 5 nm faiblement agglomérées. Ces travaux ont montré dans l'ensemble que différents mécanismes de toxicité pulmonaire peuvent être empruntés par les NP de TiO2 en fonction de la taille de départ et de l’état d’agglomération. / Given their small size, nanoparticles (NP) (< 100 nm) can coagulate quickly, which promotes their entry into the body in the form of agglomerates. The objective of this study is to evaluate the influence of the agglomeration state of three different primary particle sizes (5, 10-30 and 50 nm) of titanium dioxide (TiO2) NP on the pulmonary toxicity of male rats (F344) exposed to aerosols at 2, 7 or 20 mg/m3 for 6 hours. In an inhalation chamber, six groups of rats (n = 6 per group) were acutely exposed by nose-only inhalation to aerosols with a 5-nm primary particle size, produced in the form of small agglomerates (< 100 nm) (SA) or large agglomerates (> 100 nm) (LA) at 2, 7 and 20 mg/m3. Similarly, four other groups of rats were exposed to aerosols at 20 mg/m3 with a primary particle size of 10-30 and 50 nm. The different aerosols were generated by nebulization of suspensions or by dry dispersion. For each mass concentration, one group of control rats (n = 6 per group) was exposed to compressed air under the same conditions. The animals were sacrificed 16 hours after the end of exposure, and analysis of the bronchoalveolar lavage fluids was used to measure markers of inflammatory, cytotoxicity and oxidative stress effects. Lung sections were also analyzed for histopathology. The influence of the agglomeration state of TiO2 NP (5 nm) could not be determined at 2 mg/m3. For mass concentrations of 7 and 20 mg/m3, our results showed that an acute inflammatory response was induced following exposure to LA aerosols. In addition to this response, exposure to SA aerosols resulted in a significant increase in 8-isoprostane and lactate dehydrogenase. At 20 mg/m3, the cytotoxic effects were greater after exposure to the 5-nm NP in the SA aerosol. This study showed that TiO2 NP use different mechanisms to induce their pulmonary toxicity as a function of their primary particle size and their agglomeration state.
4

Procédé d'élimination de la pollution de l'air par traitement photocatalytique : application aux COVs / Remediation process of air polllution using photocatalytic treatment : study of VOCs

Vincent, Guillaume 04 September 2008 (has links)
L’oxydation photocatalytique des Composés Organiques Volatils (COVs) apparaît comme un procédé très prometteur pour la réduction de la pollution atmosphérique. Ce travail avait pour objectif d’étudier l’oxydation photocatalytique de plusieurs COVs au sein d’un réacteur annulaire: méthyléthylcétone (MEK), acétone, 1-propanol ou encore triéthylamine (TEA). Dans une première partie, l’influence de plusieurs paramètres cinétiques tels que la concentration en polluant, l’intensité lumineuse, le temps de contact et le taux d’humidité a été étudiée. Un mécanisme de dégradation photocatalytique a été établi pour chaque polluant en fonction des sous-produits détectés par GC/MS. Dans une seconde partie, la diffusion de radicaux hydroxyles OH• dans la phase gazeuse, après activation photonique du TiO2, a été mise en évidence par Fluorescence Induite par Laser (LIF). Pour la première fois, ces radicaux OH• ont été détectés à des pressions proches des conditions atmosphériques. Dans ce cas, nous pouvons en conclure que la dégradation photocatalytique des COVs pourrait être partiellement due à une réaction en phase gazeuse entre les COVs et les radicaux OH• / Photocatalytic oxidation of airborne contaminants appears to be a promising process for remediation of air polluted by Volatile Organic Compounds (VOCs). The aim of our study is the photocatalytic oxidation of several VOCs using an annular reactor: methylethylketone (MEK), acetone, 1-propanol and triethylamine (TEA). First, the influence of different kinetic parameters such as pollutant concentration, incident light irradiance, contact time and humidity has been studied. A mechanistic pathway has been indeed proposed for each pollutant according to the produced intermediates species detected by GC/MS. Second, the diffusion of hydroxyls radicals OH• in gas phase, after photonic activation of TiO2, has been highlighted using Laser-Induced Fluorescence (LIF). For the first time, OH• radicals have been detected at atmospheric pressures, close to the major photocatalytic oxidation conditions, leading to the assumption that the photocatalytic degradation of VOCs might be at least partially occurs between pollutants and OH• radicals in gas-phase

Page generated in 0.076 seconds